Ajmer Vidyut Vitran Nigam Limited - Rajasthan

34946387 e tender for insulated rabbit conductor earthing set rod type 11 kv xlpe cables, lt pvc armoured cable, 33 kv strain insulators, 11 kv strain insulators, ct pt set, fabricated steel items, 33 kv lighting arrestor, lt power capacitors, lt power armoured cable, fabricated steel item, d/p set, fabricated steel items, ms nut and bolts, rate contract for supply of pre printed continuous computer stationary. rate contract for printing of stationary without paper and allied works, isolating switches, pin insulator, pins. rate contract for repairing of three phase distribution transformers, gi stay set, gi stay wire, earth wire, transformer oil, lt tv meter static, 33 kv xlpe cables, tong tester, ht tv meters static c type, semi automatic meter testing bench for 3 phase meter etc....

Indian Army - Rajasthan

34880939 bids are invited for s and f fr is pvc insulated copper conductor, single core cable in surface recessed as required of size 2x4.00 sqmm 1x4.00 sqmm earth wire, in pvc conduit , s and f fr is pvc insulated copper conductor, single core cable in surface recessed as required of size 2x6.00 sqmm 1x6.00 sqmm earth wire, in pvc conduit , s and f , single pole and netural enclosure with a two pin and earth plug and socket complete with one single pole mcb 20 amp , supply and install split ac complete 3 star rating 2 ton , supply and install split ac complete 3 star rating 1.5 ton total quantity : 564...

Ministry Of Railways - Rajasthan

34779143 bids are invited for come along clamp for catenary wire please refer item no 1 of table in para 13 of boq condition of contract for item specification , come along clamp for contact wire please refer item no 2 of table in para 13 of boq condition of contract for item specification , come along clamp for feeder wire please refer item no 3 of table in para 13 of boq condition of contract for item specification , come along clamp for earth wire please refer item no 4 of table in para 13 of boq condition of contract for item specification , d schackles set of one each please refer item no 5 of table in para 13 of boq condition of contract for item specification , single sleeve pulley block groove steel please refer item no 6 of table in para 13 of boq condition of contract for item specification , single sleeve pulley blockgroove fibre please refer item no 7 of table in para 13 of boq condition of contract for item specification , single sleeve pulley blockgroove steel please refer item no 8 of table in para 13 of boq condition of contract for item specification , contact wire twist cum bender 6 inch please refer item no 9 of table in para 13 of boq condition of contract for item specification , steel sling with eye each end 19mm dia and 1m long please refer item no 10 of table in para 13 of boq condition of contract for item specification , steel sling with eye each end 19mm dia and 2 mtr long. please refer item no 11 of table in para 13 of boq condition of contract for item specification , steel sling with eye each end 19mm dia and 3 mtr long please refer item no 12 of table in para 13 of boq condition of contract for item specification , steel sling with eye each end 19mm dia and 4 mtr long please refer item no 13 of table in para 13 of boq condition of contract for item specification , steel sling with eye each end 19mm dia and 10 mtr long please refer item no 14 of table in para 13 of boq condition of contract for item specification , ra...

Ministry Of Railways - Rajasthan

34676155 bids are invited for come along clamp for catenary wire please refer item no 1 of table in para 13 of boq condition of contract for item specification , come along clamp for contact wire please refer item no 2 of table in para 13 of boq condition of contract for item specification , come along clamp for feeder wire please refer item no 3 of table in para 13 of boq condition of contract for item specification , come along clamp for earth wire please refer item no 4 of table in para 13 of boq condition of contract for item specification , d schackles set of one each please refer item no 5 of table in para 13 of boq condition of contract for item specification , single sleeve pulley block groove steel please refer item no 6 of table in para 13 of boq condition of contract for item specification , single sleeve pulley blockgroove fibre please refer item no 7 of table in para 13 of boq condition of contract for item specification , single sleeve pulley blockgroove steel please refer item no 8 of table in para 13 of boq condition of contract for item specification , contact wire twist cum bender 6 inch please refer item no 9 of table in para 13 of boq condition of contract for item specification , steel sling with eye each end 19mm dia and 1m long please refer item no 10 of table in para 13 of boq condition of contract for item specification , steel sling with eye each end 19mm dia and 2 mtr long. please refer item no 11 of table in para 13 of boq condition of contract for item specification , steel sling with eye each end 19mm dia and 3 mtr long please refer item no 12 of table in para 13 of boq condition of contract for item specification , steel sling with eye each end 19mm dia and 4 mtr long please refer item no 13 of table in para 13 of boq condition of contract for item specification , steel sling with eye each end 19mm dia and 10 mtr long please refer item no 14 of table in para 13 of boq condition of contract for item specification , ra...

Local Self Government Department - Rajasthan

34579171 bids are invited for led street light aerial bunchedcable , gi bracket , shackle insulator , cross arm , led street light , gi stay set , suspension clamp , dead end clamp , lt connector type a b , cu flex wire , timer panel , earth wire strip , gel earthing total quantity : 27206...

Central Organisation Railway Electrification - Rajasthan

34251190 supply of come along clamps for earth wire 19 / 2.5mm galvanized steel capacity 2.5tonne with load test certified from govt. approved laboratory.make srec, pvce, sste. ] come along clamps for earth wire 19 / 2.5mm galvanized steel capacity 2.5tonne with load test certified from govt. approved laboratory.make srec, pvce, sste. ] , come along clamps for earth wire 19 / 2.5mm galvanized steel capacity 2.5tonne with load test certified from govt. approved laboratory.make srec, pvce, sste....

Medical And Health Services - Rajasthan

34206683 construction of shc bejpur block itawa distt. kota 1 clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 2 earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift upto 1.5 mtr. including taking out the excavated soil and depositing and refilling of jhiri with watering and ramming and disposal of surplus excavated soil as directed within a lead of 50 mtr. all kinds of soil 3 filling in plinth with locally available river shingle under floors including watering ramming consolidating and dressing complete including cost of shingle sand. 4 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level.1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). 5 centering and shuttering with plywood or steel plate including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 6 providing and laying in position specified grade ofcement concrete forall rcc structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement.m20 grade nominal 7 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.m20 grade nominal mix 8 centering & shuttering with plywood or steel plate including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor three level for :columns, pillars, posts and struts etc. 9 centering & shuttering with plywood or steel plate including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor three level for :suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 10 random rubble stone masonry for foundation and plinth in cement sand mortar above 30 cm thick wall in :cement mortar 1 : 6 (1 cement : 6 sand). 11 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.m20 grade nominal mix 12 providing and fabricating reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. thermo mechanically treated bars (conforming of relevent is code) 13 filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead upto 50 mtr. and lift upto 1.5 mtr. 14 filling in plinth withlocally available good earth under floors including watering ramming consolidating and dressing complete including cost of locally available good earth 15 flyash flyash brick work with flyash flyash bricks of class designation 75 in superstructure above plinth level upto floor three level in all shapes and sizes in :cement mortar 1 : 6 (1 cement : 6 coarse sand) 16 half flyash brick masonry in superstructure , above plinth level upto floor three levelusing flyash bricks of designation 75 cement mortar 1 : 6 (1 cement : 6 coarse sand 17 random rubble dry stone kharanja under floor. 18 providing and fixing 15 to 20 mm thick granite stone slab mirror polished and machine edge cut in walls, pillars, steps, shelves, sills counters, floors etc. laid on 12 mm (av.) thick base of cement mortar 1 : 3 (1 cement : 3 coarse sand) jointing with white cement mortar 1 : 2 (1 white cement : 2 marble dust) with pigment to match the shade of the granite slab complete including rubbing and polishing of :green / black / other granite. above 3601 cm2 slabs 19 providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to is : 13753 & is :15622 of size 300mm x 450mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 20 providing and fixing 1st quality mat finished ceremic tile size 300 x 300 mm confirming to is : 13753 colour such as white, grey, ivory, fume red brown in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry including nicely finished joints using water proof joint filler powder (untile of roffe make) and finishing with flush pointing in white cement mixed with pigment to match the shade of the complete (including the cost of cement mortor bed1:4). category a : kajaria, jhonson, somani make 21 providing & fixing vitrified paving tiles size 600 mm × 600 mm × 12 mm thick fix with cement mortar over 20 mm thich (1 cement 4 sand) laid on a bed of neat cement slurry including nicely finished joints using water proof joint filler powder (untile or roffe make) and finishing with flush pointing in white cement mixed with pigment to match the shade of tile complete (including the cost of cement mortor 1:4) category a : kajaria, jhonson, somani make 22 providing and fixing external grade board solid core single leaf flush door shutters isi 2202 67 marked using phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure a :30 mm thick commercial veneer both side 23 add extra in flush doors :for double leaf 24 for external teak wood lipping on flush door30mmx6mm 25 extra for cutting rebate in flush door shutters (total area of the shutter to be measured). 26 providing and fixing anodised aluminium curtain rod with aluminium brackets complete :25 mm dia 27 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded with 15 x 3 mm lugs, 10cm long embedded in cement concrete blocks 15 x 10 x 10 cm of 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 28 supply and fixing in cement mortar welded hand railing made out of ms round or square bars, flats etc. for staircase or verandah as per design complete in all respect (wooden or pvc hand railing to be paid extra) with priming coat of red oxide. 29 providing and fixing steel gate grating and grills made of angles, tees, square bars or other flats black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. 30 providing and fixing m.s. sheet single leaf door shutter in angle iron frame 35 x 35 x 5 mm suitabilly diagonally braced with 25 x 3 mm flat iron above and below lock rail of size 50 x 5 mm beading extra including all fittings, as per direction of engg. incharge but excluding cost of chowkhats : including two coats of anit corrasite red oxide primer paint. m.s. sheet 18 s.w.g. 31 supplying and fixing of steel windows made out (65 x 40 mm) hollow metal pressed section of 1.25 mm thick sheet f4 & f7 standard rolled section conforming to is 1038 with wholly openable shutter of 0.80 mm thick (out side & inside) opening c.r. sheet embossed panels, joints matted and flush welded with suitable hinges, steel lugs & screws with approved oxidised steel handles, fittings, peg stays (casement stays) etc. complete in all respect including providing 10 mm square m.s. bars 10 cm. c/c and applying priming coat of red oxide paint. 32 supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20 x 3 mm with suitable screw at not exceeding 150 mm distance. 33 providing batta (gola) 75 mm x 75 mm in cement concrete (1 : 2 : 4) including finishing with cement mortar 1 : 3 as per standard design. 34 providing & laying chequerred plain cement concrete embossed to specially manufactured non slipping tiles of approved make 20 mm thick laid on 20 mm thick bed of cement mortar 1 : 6 jointed with neat cement slurry complete.medium shade using approximately 50% white cement and 50% ordinary cement. 35 plaster on new surface on walls in cement sand mortar 1 : 6 including racking of joint etc. complete fine finished :25 mm thick 36 plaster on new surface on walls in cement sand mortar 1 : 6 including racking of joint etc. complete fine finished :20 mm thick 37 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand). 38 applying priming coat :with ready mix pink or gray primer of approved brand and manufacture on wood work hard and soft wood. 39 painting with enamel paint of approved brand and manufacture to give an even shade :two or more coats on new work. 40 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including prepration of base and all scaffolding :new work (two or more coats) over and including scrapping and priming coat with cement primer. 41 painting exterior surface ofwallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect. new work 42 renewing glass panes, with putty and nails wherever necessary :4 mm thick plain glass panes. 43 supplying and fixing dressed sand or other approved stone shelves, tands in cement mortar 1 : 3 with fine dressed edges : 35 mm thick. 44 supplying and fixing in walls machine cut and polished stone shelves, tands andin cm 1:3 with machine cut edges :kota stone 25 to 30mm thick. 45 making of health wellness center patern (gola) including colour picture work in side for fascasde branding includig material labour and t & p as pe direction engineer in charge as per standared drawing/patern 46 making of border of window health wellness center as per given patern for fascasde branding includig material labour and t & p as pe direction engineer in charge up to window size 4x5.6 as per standared drawing/patern 47 extra for providing edge moulding to 15 18mm thick marble/ granite stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge.granite work / kota stonefull edge moulding 48 providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth completebirla/j.k./nerolac or iso. as per direction of engineer in charge. 49 providing& fixing precast cement concrete coping 1: 2:4mix50mmthickcompleteas per specification 50 finishing with 25 mm thick cement plaster on roofs in cement sand mortar 1 : 4 mix including water proofing compound @ 2% of cement used. with neat cement, finishing, curing etc. complete in all respect including making of 300 mm x 300 mm square. 51 providing and fixing indian type white glazed vitreous china 1st quality w.c. orissa pan (is : 2556 mark) with 100 mm vitreous china p or s trap including cutting and making good the wall and floor. size 580 x 440 mm 52 p & f wvc wash basin (1st quality is : 2556 mark) of approved make with c.i. brackets duly painted, 1 no. 15 mm c.p.pillar cock (is : 8934 mark) & 32 mm c.p. brass waste coupling of approved make, 25 mm g.i. waste pipe complete including cutting & making good the wall. size 510 mmx 400 mm 53 p & f wvc wash basin (1st quality is : 2556 mark) of approved make with c.i. brackets duly painted, 1 no. 15 mm c.p.pillar cock (is : 8934 mark) & 32 mm c.p. brass waste coupling of approved make, 25 mm g.i. waste pipe complete including cutting & making good the wall. size 550 x 400 mm dia for counter top 54 p & f kitchen & lab sink of approved make with c.i. brackets duly painted, 40 mm c.p. waste coupling, c.p. brass chain with rubber plug, 40 mm g.i. waste pipe upto floor level complete including cutting & making good the wall & floor. 1.0 mm thick salem stainless steel aisi 304 kitchen sink of approved make (nirali, neel kanth, jaina, faber, criystal ) with large waste couplings is 13983 1994 over all size bowl size(inches) (inches)24 x 18 x 8 20 x 16 x 8 55 p & f looking mirror with pvc frame of approved (atul/ equivalent)size 500 x 400 mm 56 providing and fixing towel rail or ring of approved quality / make. c.p. brass towel rail with brackets 450 x 20 mm. 57 providing and fixing soap dish or tray of approved quality / make. c.p. brass 58 providing and fixing bath shower of approved quality / make. c.p. brass of heavy & superior quality 150 mm. 59 providing & fixing c.p. flange for 15 mm dia taps 60 p & f bib cock (is: 8931 mark) superior quality of approved make c.p. brass bib cock, 15 mm nominal bore 61 providing and fixing inlet connection (angle, valves) superior quality, of approved make.for wash basin gyser etc.c.p. inlet connection 15 mm.brass (is: 8931 marked) 62 providing and fixing 15 mm dia connection pipe of approved quality / make. pvc pipe with cp brass nuts upto length 600 mm 63 providing and fixing flush cock / flush valve (is : 9758 mark) for wc of approved quality make. c p brass half turn exposed 25 mm nominal bore 64 providing and fixing full way valve (is : 778 mark) or wheel valve of approved make. gun metal 15 mm nominal bore 65 providing and fixing full way valve (is : 778 mark) or wheel valve of approved make. gun metal 25 mm nominal bore 66 providing and fixing pvc storage tank confirming to is : (12701 marked indicating the bis license no) of approved make with cover, 25 mm dia 1 m long g.i. over flow pipe & 25 cm. long wash out pipe with plug & socket, including making connection etc. complete of approved design.500 litres capacity 67 hoisting charges for each floor. 68 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. (internal work exposed on wall) 20mm nominal outer dia pipes 69 providing and fixing 3 layer pp r (polypropylene random coplymer ) pipes sdr 7.4 uv stabilized and antimicrobial fusion welded, having thermal stability for hot & cold water supply including all pp r plain & brass threaded polypropylene random fittings including trenching, refilling and testing of joint complete as per direction of engineer in charge. (external works)pn 16pipe, 32 mm od 70 providing and laying c.c. 1 : 5 :10 (stone aggregate 40 mm nominal size) upto haunches of s.w. pipes including 150 mm thick bed concrete as per rajasthan pwd specifications : (width w = dia of pipe in cm + 40 cm.) concrete width to be reduced from width w at centre of pipe to 0 at top of pipe.(excluding cost of pipe )100 mm dias.w. pipe 71 providing and fixing rigid pvc pipe (is : 4985 mark) class ii (4 kg./cm2) approved quality / makeincluding jointing the pipe with solvent cement rubber ring and lubricant. 110 mm dia 72 providing and fixing rigid pvc pipe fittings (is : 4985 mark) of approved quality / make including jointing the pipe with solvent cement rubber ring and lubricant. 110 mm dia coupler (socket) 73 providing and fixing rigid pvc pipe fittings (is : 4985 mark) of approved quality / make including jointing the pipe with solvent cement rubber ring and lubricant. 110 mm dia plain tee 74 providing and fixing rigid pvc pipe fittings (is : 4985 mark) of approved quality / make including jointing the pipe with solvent cement rubber ring and lubricant. 110 mm dia bend 45° 75 providing and fixing rigid pvc pipe fittings (is : 4985 mark) of approved quality / make including jointing the pipe with solvent cement rubber ring and lubricant. 110 mm dia bend 87.5° 76 providing and fixing rigid pvc pipe fittings (is : 4985 mark) of approved quality / make including jointing the pipe with solvent cement rubber ring and lubricant. 110 mm dia vent cowel 77 providing and fixing rigid pvc pipe fittings (is : 4985 mark) of approved quality / make including jointing the pipe with solvent cement rubber ring and lubricant. 110 mm dia pipe clip 78 construction of chamber in all types of soil with 300 mm thick masnory in cm. 1 : 6, 100 mm thick c.c. 1 : 5 : 10 in foundation , 20 mm thick inside plaster in cm 1 : 6, finished with floating neat cement 50 mm thick m 15 grade c.c. flooring earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. inside size 450 x 450 mm depth upto 0.5 m cement coverwith frame 79 construction of chamber in all types of soil with 300 mm thick masnory in cm. 1 : 6, 100 mm thick c.c. 1 : 5 : 10 in foundation , 20 mm thick inside plaster in cm 1 : 6, finished with floating neat cement 50 mm thick m 15 grade c.c. flooring earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. inside size 600 x 450 mm upto depth of 0.5 m cement cover with frame 80 construction of soakage well in all types of soil 300mm thick dry stone masonry, top and bottom 300 mm course in cm 1 : 6, 80 mm thick stone slab, jointing of slab in cm 1 : 3, ralthal, kharanja, 40 mm thick m 15 grade c.c. flooring earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr. size 240 cm dia outside & 240 cm depth 81 construction of septic tank in all types of soil with 40 cm. thick masonry in cm 1 : 6, 15 cm. thickc.c. bed of 1 : 5 : 10, m 15 grade c.c. flooring & over stone slab covering, 80 mm thick slab, jointing of slab in cm 1 : 3 ralthal, kharanja, 50 mm thick stone partition walls, 20 mm thick plaster in cm 1: 6 finished with neat floating cement, 4 nos c.i. foot rests of approved design, two no. 450 mm dia 25kg. of each c.i. cover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr. size 200 x 100 x 130 cm (for 10 users) 82 construction of cement concrete chamber 125mm dia on depressed floor upto 45cm height from floor with : stainless steel sheet grating 83 wiring of light point/ fan point/ exhaust fan point/ call bell point as per pwd specification for electrical works with isi marked 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade (is:694) and 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade (is:694) in recessed isi marked mms ( is:9537 p iii ) vergin material pvc conduit & its all accessories( j.b. , bends etc.) , round tiles,18 swg hot dipped galvanized modular box with earth terminal, 6 a modular switch, modular face plate with grid plate, 3 pin ceiling rose / lamp holder/ 3 pin connector , screws etc, making connections,all as per pre approved by engineer in charge, testing etc. complete as required. for specification of copper conductor, phenolic laminated sheets & electrical/ wiring accessories refer chapter e 04, e 05 & e 07 . for additional technical parameters of products/ work , refer annexure a attached with this bsr short point (up to 3 mtr.) 84 medium point (up to 6 mtr.) 85 long point(up to 10 mtr..) 86 wiring of 3/5 pin 6 amp. light plug point as per pwd specification for electrical works with isi marked 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade (is:694) and 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade (is:694) in recessed isi marked mms ( is:9537 p iii ) vergin material pvc conduit & its all accessories( j.b. , bends etc.) , round tiles, 18 swg hot dipped galvanized modular box with earth terminal, 6 a modular switch, 3/ 5 pin 6 a modular socket, modular face plate with grid plate, screws etc,all as per pre approved by engineer in charge, making connections, testing etc. complete as required. for specification of copper conductor, phenolic laminated sheets & electrical/ wiring accessories refer chapter e 04, e 05 & e 07. for additional technical parameters of products/ work refer annexure a attached with this bsr on board 87 medium point (up to 6 mtr.) 88 s&f following sizes (dia.) of isi marked mms ( is:9537 p iii ) vergin material pvc conduit as per pwd specification for electrical works along with its accessories (is: 3419 ) as required in recess including cutting the wall, covering conduit and making good the same as required. all relative and latest acceptance tests reports by any nabl accredited lab for the conduit shall be submitted before execution & all as per pre approved by engineer in charge. for additional technical parameters of products/ work , refer annexure a attached with this bsr 20 mm 89 25 mm 90 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked (is:694) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from 99.99% purity copper, class 5 stranding in acc. to iec 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation pvc type a ,flame retardant as per is 10810 53, better amperage rating as per vde 0298 part 4, , in existing surface or recessed pvc/ ms conduit/casing capping including all as per pre approved by engineer in charge,making connections, etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of products/ work , refer annexure a attached with this bsr 2 x 2.5 sq. mm. + 1x1.5sqmm 91 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 92 supplying and fixing of power plug point with modularaccessories as per pwd specification for electrical works, on hot dipped galvanized modular box of 18 swg with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of isi marked modular 16 amp. switch (is :3854) and 3/5 pin 16 amp. socket outlet (is:1293) [ as per detailed in respective item in bsr] , making connection , testing , etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products/ work , refer annexure a attached with this bsr 93 providing & fixing of modular type step fan regulator duly isi marked (is :11037) as per pwd specification for electrical works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with ip 20 rating , minimum width of 1 module switch toggle( push part ) should not less then 20mm, including all as per pre approved by engineer in charge,making connections, testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products/ work , refer annexure a attached with this bsr 5 step fan regulator 100 watt 2 module 94 providing & fixing of heavy duty capacitor start, copper woind double ball bearing 900/1400 rpm single phase exhaust fan as per pwd specification for electrical works, conforming to is:2312 isi marked in existing opening including making connections testing etc. as required. oem shall be an iso certified company. appropriate oem test certificate shall be submitted by contractor. all as per pre approved by engineer in charge. for additional technical parameters of products/ work , refer annexure a attached withthis bsr .300 mm sweep(900/1400 rpm) 95 providing & fixing of ik07 ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum lm6/ adc12 material with heat dissipation fins on housing with uv stabilized pc/toughened glass cover (uv stablzation report submitted for uv cover ) and secondary lens on each led & should be smd type . the system level luminaire efficacy >=120 lm/ wt with high power leds is to be used and potted driver must be potted & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety ,input frequency 50hz±3% power factor >0.95 driver efficiency >85% ,thd(i) <10% humidity 10% to 90% rh working temp 5c to 45c . driver current <1000ma shown in lm79 report. the luminaire shall be bis certified and t.c. certified. life expectancy equal or more than 50000 burning hrs with minimum 70% lumenmaintened,colorrendering index>70 andcct 5700k+355k. surge protection shall be min = 4 kv internal and min 10 kv external. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities for led fixtures. (lm79/lm80) certificate/ report with liable warranty of product/accessories from oem shall be submitted. all as per pre approved by engineer in charge. for additional technical parameters of products/ work , refer annexure a attached with this bsr led street light fixture 70 watt 96 providing & fixing of 240/415 v ac mcb with positiveisolation of breaking capacity not less than 10 ka (b/ c tripping characteristic as per type of load and site requirement) 4kv impulse withstand voltage, as per pwd specification for electrical works with isi marked is 8828(1996) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , ip 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 a rating and 10,000 upto 63 a, 5000 for 80 a rating including making connections, testing etc. as required. . oem shall have submit nabl / cpri / erda accrediated lab test reports before execution & all as per pre approved by engineer in charge. for additional technical parameters of products/ work , refer annexure a attached with thisbsr .single pole mcb6 a to 32 a rating 97 double pole mcb50 63 a rating 98 providing & fixing of ik09 recessed/surface mountingheavy duty horizontal type sheet steel of 1.6 mm thick distribution board as per pwd specification for electrical works isi marked conforming to is 13032 & is 8623 / conforming to iec 61439 3. phosphatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link , connecting wire of suitable rating and din bar,masking sheet, including making internal db terminations with copper lugs and with detachable gland plate, including making connections, testing etc. as required.oem shall have submit nabl / cpri/ erda accrediated lab test reports before execution & all as per pre approved by engineer in charge. for additional technical parameters of products/ work , refer annexure a attached with this bsr ip 43 double door (single phase)6 way (6 o/g +2 i/c ) 99 supply & laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with gi/cu thimble etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products/ work , refer annexure a attached with this bsr 8 swg copper wire 100 providing & fixing of ip40 led recessed / surface mounted, round / sqaure non dimmable back lit smd mid power led downlight with die cast aluminum housing & heat sink for heat dissipation with uv stabilized non yellowish diffuser with internal/ external bis complience 2.5 kv surge protected isolated driver, with short & open circuit protection, having efficiency > 85% and in compliance to iec standards. system lumen efficacy of = 120 lm / watt, thd < 10 % ,p.f.=0.95, cri >80, life time of minimum 50000 burning hours with , 70% of intial lumen maintaned till life ends , cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as per ansi bin) ,maximum power consumption should not more than the specified rating and fixture shall be of bis standard and trade mark certificate ( t.c.). manufactures word mark/ name engraved/ embossing/ screen printing on housing.oem must have its own in house nabl lab setup for all testing facilities for led fixtures. (lm79/lm80) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer annexure a attacheded with this bsrrecessed mountingled downlight 18/20w 101 providing & fixing of ip40 led surface/ recessed / suspended mounting mid power smd type led light fixture made from crca sheet steel housing, high purity / transmisivity uv stabilized non yellowish diffuser for uniform light distribution. high efficiency with 2.5 kv internal/external surge protection bis certified isolated driver having efficiency > 85% , with short & open circuit protection and in compliance to iec standards (integral with light fixture). system lumen efficacy of = 120 lm/watt ,thd < 10 % , p.f.=0.95,cri >80 , life time of minimum 50000 burning hours with , 70% of intial lumen maintaned till life ends , cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as per ansi bin) , maximum power consumption should not more than the specified rating and fixture shall be of bis standard and trade mark certificate ( t.c.). manufactures word mark/ name engraved/ embossing/ screen printing on housing.oem must have its own in house nabl lab setup for all testing facilities for led fixtures. (lm79/lm80) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer annexure a attacheded with this bsrrecessed mounting36w led light fixture 2x2 with acrylic / prismatic front cover 102 providing & fixing of ip20 smd mid power led batten type integrated light fixture made from polycarbonate /extruded aluminium powder coated housing with in built driver , power consumption of 18w/20w ,system lumen efficacy = 120 lm/watt output, internal surge protection of 2.5 kv with short & open circuit protection ,thd < 10% ,p.f.=0.95, cri >80 , life time of minimum 50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k/ 5700°k /6000°k/6500°k (as per ansi bin) , maximum power consumption should not more than the specified rating and fixture shall be of bis standard and trade mark certificate ( t.c.). manufactures word mark/ name engraved/ embossing/ screen printing on housing.oem must have its own in house nabl lab setup for all testing facilities for led fixtures. (lm79/lm80) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer annexure a attacheded with this bsr.4 led tube shape fixture 18/20 w (polycarbonate base) 103 sitc of chemical gel earthing system of dual pipe technology made of with b class g i pipe as per is 1239 ( part 1):2004 of medium duty of following sizes as per points mentioned (a), (b), [c), (d), (e) below : (a) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, cpri/ erda tested with rms capacity of minimum 35 40 ka for withstanding 1 second(b) to ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. the compound shall be tested form nabl acredeated lab for low resistivity ( less than 0.12 ohm meter) & high conductivity in nature with carbon as a major content as per referance of is 3043 1987,ieee 80 2013 (clause 14.5d) , ieee 837 & ier 1956 with latest amendemnts©heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height 250 to 300 mm.(d) testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.(e) self certificate for confirming above standards from oem is mandatory. all as per pre approved by engineer in charge. for additional technical parameters of products/ work , refer annexure a attached with this bsr .with pipe in pipe technology (outer pipe dia. / inner pipe dia. ) minimum 100 mm dia borewellgi pipe 2000 mm long, 80 / 50 mm, terminal 50mm x 6 mm gi strip 104 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed un armoured / armoured aluminium cable of 1.1 kv grade as per pwd specification for electrical works in existing rcc / hume / stoneware / pvc pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below: (a) material : h4 grade aluminium conductor of purity >99.6 %& as per is:1554 p i / is :7098 p i(b) conductor shall have electrolytic aluminium confirming to is 8130, is 3975 1999 for armouring of cables in armoured cable items , is 5831 for sheath, is 10810 (part 0 to 64 ) for testing procedures .(c) oem must have iso 9001 & 14001 certifications for quality assuarance & its own in house nabl lab setup for all testing facilities for cables . appropriate type test certificate / oem test report shall be submitted . all above as per pre approved by engineer in charge. for additional technical parameters of products/ work , refer annexure a attached with this bsr . armoured cable10.0 sq. mm2.0 core 105 providing & fixing of iso certified company made bee star rated copper wounded double ball bearing capacitor start, aluminium body & metallic blade ceiling fan as per pwd specification for electrical works, conforming to is:374 2019, & is:1885 p v 1981. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. appropriate oem test certificate shall be submitted by contractor. all as per pre approved by engineer in charge. for additional technical parameters of products/ work , refer annexure a attached with this bsr 1200 mm sweep bee 2 star rated (service value >=4.5 to < 5 ) 106 supply & fixing of abc type (map 50) type powder fire extinguisher (stored pressure type) of following capacity duly current and valid bis certification conforming to is: 15683:2006, with dry chemical powder used as extinguishing agent should be mono ammonium phosphate 50% concentration conforming to is 14609:1999. oem will produce supplier certificate complete with squeeze grip release valve, locking arrangement, pressure gauge and bracket including initial fill and wall suspension complete in all respect. serial no. and date of manufacturing should be embossed or printed on the body of the fire extinguisher. the firm should submit the product certificate from an en notified body & product performance test report from nabl accredited lab as per is 15683. . all as per pre approved by engineer in charge. for additional technical parameters of products/ work , refer annexure a attached with this bsr 4 kg 107 supply installationtesting&commissioningofisocertified manufacturer made monoblock motor pump set isi marked (is:9079 2002) with tefc motor, motor should be ie2 class as per iec 60034 2 1: 2007, iec 60034 30: 2008, & is12615:2011. with stainless steel impellor, stainless steel shaft, mechanical seal, single/three phase ( 240 440 v ) permanent split capacitor type (psc), fitted with thermal overload protection, . including cost of hardware etc on existing platform complete. pump shall have following hp rating, phase, head, minimum discharge respectively complete in all respect. appropriate type test certificate / oem test report shall be submitted. all as per pre approved by engineer in charge. for additional technical parameters of products/ work , refer annexure a attached with this bsr 0.5 hp, 1 ø, (3 18)mtr, (100 26) lpm 108 construction of tube well 100 metre depth and above in all type of rocks by dth system and over burden, to accommodate casing pipe of following size in all types of soils and over burden including lowering of casing pipes, but excluding cost of casing pipes as per is : 2800 (part i & ii) 1979 specifications. the work would be completed after obtaining sand free water. the tube well should have a throughout bore as per nominal dia of casing pipe. 200 mm dia nominal bore 109 development of tube well as per is specifications using suitable compressor to give sand free water for required yield of the gravel packed tube well. 110 supply of erw m.s. black casing pipe isi marked (is : 4270/1992) of grade fe 410 of following sizes at site of work. nominal bore of pipe200 (mm) 111 supply & fixing tube well cover of m.s. sheet (6 mm thick) with nuts and bolts complete for casing size. 200 mm dia 112 supply & fixing m.s. clamp, set of 50 x 6 mm flat from iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. 113 providing & fixing of single stage, water cooled, high speed(2880 rpm), horizontal, centrifugal, openwell submersible pumps set pre filled with coolent water and fitted with mechanical seal t/c vs t/c, thrust bearing shall be of carbon + s.s.the stator body of single phase pump shall be of ss and rest of all shall be of cast iron. all casting parts should be cathod electro deposition (ced) coated and other construction material should be confirming to is : 14220: 2018 . the overall performance of pump shall confirm to bee energy efficiency level of 3 star. valid bee certificate from oem must be submitted for the same. motor should be ie2 class as per iec 60034 2 1: 2007, iec 60034 30: 2008, & is12615:2011, including making connection etc as required complete in all respect. all as per pre approved by engineer in charge. for additional technical parameters of products/ work , refer annexure a attached with this bsr 2.0 hp, 1 ø, (12 25) mtr, (350 115) lpm 114 supplying andlaying isimarkedp.v.c. insulated submersible cable as per pwd specification for electrical works confirming to is:694 and as per is 8130 : 2013 of 1.1 kv grade .wire should be made from 99.99% purity copper, class 5 stranding in acc. to iec 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation pvc type a ,flame retardant as per is 10810 53, better amperage rating as per vde 0298 part 4 including making connection etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. all as per pre approved by engineer in charge, making connections. for additional technical parameters of products/ work , refer annexure a attached with this bsr 6.0 sq.mm 3 core flat / round 115 providing & fixing of hdpe pipe isi mark (is:4984/2016 ) for watersupply (suitable for submersible & jet pump) with required fittings ie socket, elbows, tee etc. complete in all respect. all as per pre approved by engineer in charge. for additional technical parameters of products/ work , refer annexure a attached with this bsr 50 mm od 6 kg / cm2 116 construction of 185 cm. dia platform as per approved design and drawing of unicef. 117 supply installation testing & commissioning of iso certified company made dol/star delta starter panel made out from 1.6 mm thick powder coated crca sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, illuminated on / off push buttons, ammeter, voltmeter, indicating lamps etc. suitable for following rating motors complete in all respect. appropriate type test certificate / oem test report shall be submitted. all as per pre approved by engineer in charge. for additional technical parameters of products/ work , refer annexure a attached with this bsr for single phase submersible / monoblockpump0.5 hp to 3.0 hp (dol starter) ...

Department Of Local Bodies - Rajasthan

34109210 supply and fixing of decorative poles in kamla nehru garden at muniicpal board mount abu supply and fixing of decorative poles in kamla nehru garden at muniicpal board mount abu , providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed armoured aluminium cable of 1.1 kv grade as per pwd specification for electrical works in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points ( a ) , ( b ) , ( c ) , mentioned below: ( a ) material : h4 grade aluminium conductor of purity >99.6 % & as per is:1554 p i / is :7098 p – i ( b ) conductor shall have electrolytic aluminium confirming to is 8130, is 3975 1999 for armouring of cables in armoured cable items , is 5831 for sheath, is 10810 ( part 0 to 64 ) for testing procedures. ( c ) oem must have iso 9001 & 14001 certifications for quality assuarance & its own in house nabl lab setup for all testing facilities for cables . appropriate type test certificate / oem test report shall be submitted . all above as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr. 6.0 sq. mm4 core , supply & laying following size earth wire in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection with gi / cu thimble etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 10 swg g.i. ( hot dipped ) wire , supply & laying following size b class , medium class g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor / strip / cable in ground / surface / recess as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 50 mm dia , providing & laying of double wall corrugated pipe confirming to is : 14930 p 1 & 2 with hdpe coupler at 1 mtr. depth below the ground for laying cable including making the trench and back filling , compaction of earth as required ( excavation of earth to be paid extra as required. ) of following outer dia. / inner dia as per is:4984:1995. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 55 / 50 mm , labour charges for excavation of 30cmx75cm size trench in cc road including refilling of excavated earth, compaction of earth, making good the same complete as required . , labour charges for excavation of 30cmx75cm size trench in loose soil including refilling of excavated earth, compaction of earth, making good the same complete as required . , plate earthing as per pwd specification for electrical works as per is:3043 with hot dipped g.i. earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. g.i. b class watering pipe , including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke / charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . , providing & fixing of 240 / 415 v ac mcb with positive isolation of breaking capacity not less than 10 ka ( b / c tripping characteristic as per type of load and site requirement ) 4kv impulse withstand voltage, as per pwd specification for electrical works with isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , ip 20 contact protection and fitted with existing distribution board / sheets, min. operation 20, 000 upto 32 a rating and 10, 000 upto 63 a, 5000 for 80 a rating including making connections, testing etc. as required. . oem shall have submit nabl / cpri / erda accrediated lab test reports before execution & all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr .single pole mcb 06 amp rating , four pole mcb 32 amp rating , providing & fixing of ac operated heavy duty 230 / 440 volt power contactor as per pwd specification for electrical works, isi marked is / iec 60947 4 1 : 2000 having provision of mechanical interlocking, auxilary contacts, din rail mounting type including making connections, testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 4 pole power contactors with following ac 1 rating 32 amp. , sitc of wall / free standing floor mounted dust and vermin proof compartmentalised cubical panel as per pwd specification for electrical works, made out of crca sheet . other parameters required as per point ( a ) , ( b ) , ( c ) , ( d ) below: ( a ) thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. load bearing structure shall be of 2.0 mm thick sheet supported by base m.s. channel if required . side walls and cable alley compartments having bolted type doors with / without detachable extension type structure ( b ) panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade the panel having pu / neoprene rubber gasket of not less than 3mm thickness , required hardware, separate detachable gland plate m.s. base channel ( min75mm ) , hinged door with locking arrangement for equipment / switchgear. ( c ) interconnection between bus bar and switchgears / cable shall be rigidly supported and made out by flexible copper wires ( up to 125 amp ) and by solid bus bar ( >125 amp ) . all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( d ) only outer area on all sides shall be measured & panel to be fabricated only from cpri approved fabricator. all as per drawing pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . , supplying and fixing of aluminium ( iec 60105 iso 209 1, 2 ) / copper ( iec 60028 ) bus bar as per pwd specification for electrical works, by means of smc / dmc type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . electrolytic grade ( cu etp ) tin coated annealed copper bus bars iacs 100% grade , providing & fixing of 110 240 v, ac, 1 ph. , 2 w astronomical time switch with surge suppressor, memory card, sunrise / sunset selectable, software for programming including making connection, etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . , supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from 99.99% purity copper, class 5 stranding in acc. to iec 60228 for lower watt loss , oxygen free ( <10 ppm ) for less chances of oxidization and higher silver content for gives better conductivity , insulation pvc type a or c , flame retardant as per is 10810 53, better amperage rating as per vde 0298 part 4, , in existing surface or recessed pvc / ms conduit / casing capping including all as per pre approved by engineer in charge, making connections, etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of products / work , refer annexure a attached with this bsr .2 x 1.5 sq.mm , 1 x 4.0 sq.mm...

Military Engineer Services - Rajasthan

34098552 special repair to bldg no. t 39 and special repair to road furniture item at mil cantt ajmer under ge nasirabad. special repair to bldg no. t 39 and special repair to road furniture item taking down cement or cement lime plaster on stone / brick wall, ceiling including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. 2 m& l for 15 mm thickrendering in cement mortar ( 1:6 ) , on stone masonary surfaces finished even and smooth, complete all as specified and directed 3 m&l for rendering 15mm thick in cm 1:4 on stone masonry, external surfaces finished even and smooth, complete all as specified and directed 4 m & l forpreparation ofnew plastered surfaces of wallsand providing two coat of cement base paint over a coat of primer, complete all as specified and directed. 5 m & l forpreparation old decorated surfaces of wallsand providing one coat of cement base paint complete all as specified and directed. 6 m & l for complete removal of existing treatment andpreparationwall surfaces and applying two coats of oil bounddistemperover a coat of primer over 1 mm thick wall care of putty complete all as specified and directed 7 m&l for preparation of new plastered surfaces and applying two coats of oil bounddistemperover a coat of primer over 1 mm thick wall care of putty complete all as specified and directed. 8 m&l for preparation of old wooden surfaces of any descriptionover 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. 9 m&l for preparation of old concretesurfaces of any descriptionover 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. 10 s & f second class hw 35mm thick, factory made, plain framed, paneled shutter ( three panels ) with panels of 9mm thick bwpgrade ply wood bonded with high quality liquid phenol formal dehyde synthetic resin adhesive conforming to is 710. the size of rails & style shall be as per is 1003 ( part i ) kiln seasoned & chemically pressure treated complete all as per specified and directed. 11 s&f 2nd class hw 35 mm thick, gauged and skeleton shutters ( three panels ) , factory made open rebated and prepare to receive glass, gauge etc ( with sash bar ) , edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing glass etc. size of members of shutter shall be as specified in ssr 2009 part i, section 8 clausemember shall be kiln seasoned& chemically pressure treated complete all as specified and directed. 12 s&f steel window / ventilator glazed and gauged ( combination ) with side hung / top hung shutters incl box type / projecting type hinges, and steel peg stay, handle & locking arrangement and frame made out of 1.25mm thick pressed steel frame complete incl necessary ac / cooler arrangement in window & guard barscomplete all as as specified and directed. note : wire mesh and sheet glass shall be measured & paid separately under respective items. 13 s & f aluminium handle fabricatedtype, anodised 150mm size conforming to is complete all as specified and directed. 14 s & f 300mm long aluminium alloy, anodised, sliding door bolts with hasps, staple ( bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all asspecified anddirected. 15 s&f aluminium, anodised, barrel tower bolt of extruded section, isi marked, 150 mm long complete all as specified and directed. 16 s&f mild steel butt hinges, medium weight, cold rolled, isi marked of size 100 mm, complete all as specified and directed. 17 m & l for rolled mild steel work angle ironas in door frame ( chowkhats ) of frame confirming to fe 290 or fe 330 including complete all as specified and directed. 18 taking down chowkhats or frames with shutters ( without taking off shutters from the frames ) exc 1.50 sqm and n.exc 4.00 sqm each and removing from site complete and making good disturbed surfaces of wall in cm ( 1:3 ) all as specified and directed. 19 taking down unserviceable chowkhats or frame with shutters ( without taking off shuters from the frames ) of any description n exc 1.50sqm and removing from site and making good disturbed surfaces of wall in cm 1:3 complete all as specified & directed. 20 m & l for preparation of new wooden surface over 10cm width or girth and applying two coats of synthetic enamel paint of ist quality over a coat of pink primer complete all as specified and directed. 21 m&l for preparation of new steel surface over 10cm width or grith & applying two coats of synthetic enamel paint of 1st quality over a coat of red oxide primer complete all as spd & directed. 22 s&f stainless steel wire cloth 0.36mm nominal dia of wire & average width ofaperture 1.40mm & fixed with wire staples complete all as spd & directed. 23 s&f 3.00 mm thick sheet glass, ordinary quality & glazing with oil putty not exc0.50 sqm each pane complete all as spd & directed. 24 s&f in repair road stud ( cat eye ) abs bodyconforming to irc 67 1977giving reflection on both sides including fixing with epoxycomplete all as specified and directed. 25 s&f in repair solar road studs made up of highly compressive materials , water resistant alluminium alloy and polycarbonates 122 x 122x 20mm with 6 ledprismatic reflective lens on each side with stemfixed inroadcomplete all as specified and directed by engineer in charge. 26 m&l for 2 3 mm thick and 100 mm wide thermo plastic reflective painting white or golden yellow all as specified as on road surfaces in marking speed breakers, centre line, edge line etc complete all as specified and directed. 27 exavating in post holes ( or similar holes ) each n.exc 0.5 cum getting out in soft / lose soil returning, filling in and ramming earth in layers n.exc 25cm, watering and removing surplus soil to a distance n.exc 50m and making good surfaces complete all as specified and directed. 28 m&l for pcc 1:3:6 type c 2 using 40mm graded aggregate as in foundation filling and mass concrete complete all as specified and directed. 29 m&l for 1.65mm thick & 50 mm bore ( outer dia 60.3mm ) stainless steel pipe of schedule 5 s sign board complete all as specified and directed. 30 s&f informatory sign board in reqd size and each sign board made of two 4mm thick aluminium composite panel ( acp ) , both side face to fully covered with 3m scotchlite brand high intersity prismatic grade retro reflective sheet shall be astm d 4956 type iv in required colour.the retro reflective sheet shall be processed on acp by 3m equipment heat lamp vacum applicaror and letter, signs and symbol shall be cut by computerized plotter or digital printed on retro reflective sheet with high quality eco solvent digital roland and fabricated out of high internsity prismatic grade sheeting with text matter ( as reqd ) and border of same sheeting.signboard shall be supplied along with supported circular hollow stainless steel section frame of size 25mmx25mmx1.29mm thick along with proper clamping with same section of stainless steel and nut bolts / welding, complete all as specified and directed. 31 s&f guide post delinators model no. 952 gp abs round body fitted with 2 nos 100 mm dia highly reflective reflectors made out of pmma and mounted on ms pipe of 50 duly powder coated, anti rust & anti theft steel net make ( dark eye ) complete fixing incl necessary excavation, pcc etc required complete all as specified and as directed by the engineer in charge. 32 taking down carefully copper / aluminium point wiring ( light, fan, socket or power ) complete, including fittings such as switches, ceiling roses, holders, regulators, sockets etc., removing materials from siteand making good disturbed surface of walls, floors etc complete all as specified and as directed by the engineer in charge. 33 disconnecting unserviceable sub main wiring / service connection of any size and including steel conduit and accessories and removing from site and making good the disturbed surfaces complete all as specified and as directed by the engineer in charge. 34 taking downmcb dbs complete with mcbs / isolator etc removing materials from siteand making good disturbed surface of walls, floors etc complete all as specified and as directed by the engineer in charge. 35 m&l for point wiring with 1.5 sqmm, pvc insulated, unsheathed, stranded copper conductor single core frls cable, is 694 marked, drawn through and including non metallic rigid pvc concealed conduit 20mm dia or higher complete with all pvc conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. / fittings isi marked and sunk type pressed steel anodised terminal box 1.2 mm thick with bakelite laminated sheet top cover 3 mm thick, brass screws and cup washers including 1.5 sqmm stranded copper conductor pvc insulated green in colour as continous earth conductor connected to common earth and earth dolly with all accessories for: 36 one light point controlled by one, one way switch. 37 one ceiling fan / exhaust fan point controlled by one, one way switch. 38 one three pin 5 amp socket on same board with other switches. 39 one 3 pin 5 amp socket on independent board. 40 all as per item no. 35.00 here in before but with 2.5 sqmm, for one 5 pin 5 / 15 amp socket on independent board including 2.5 sqmmstranded copper conductor ( frls ) pvc insulated green in colour as continous earth conductor connected to common earth complete all as specified and as directed by the engineer in charge. 41 s&f of submain wiring with two runs of single core pvc insulated and unsheathed multistranded ( frls ) copperconductor cable of size 6.00 sqmm lt, 1100 volts grade, drawn through and including 25 mm dia or higher pvc nonmetallic concealed conduit with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. and fittings and one run of 6 sqmm single core multistrandedcopper conductor cable green colour as earth continuity conductor complete all as specified and as directed by the engineer in charge. 42 s&f switch piano flush type 5 amps, single pole one way 240 volts complete all as specified and as directed by the engineer in charge. 43 s&f switch piano flush type 15 amps, single pole one way 240 volts complete all as specified and as directed by the engineer in charge. 44 s&fsocket outlet 3 pin 5 / 6 ampflush type complete all as specified and as directed by the engineer in charge. 45 s&fsocket out let 2 in 1, multipurpose 3 pin 15 / 16 amp flush type isi marked complete all as specified and as directed by the engineer in charge. 46 s&f ceiling fan regulator electronic flush , steped ( four step ) 230 volts ac complete all as specified and as directed by the engineer in charge. 47 s&f ceiling rose surface bakelite 3 terminals 63.5 x 17 mm complete all as specified and as directed by the engineer in charge. 48 s&f of lamp holder pvc / polycarbonate type with back plate complete all as specified and as directed by the engineer in charge. 49 s&f led tube light fitting in acrylic linear tube ( 1x 18 watt ) , 230v for single led tube lightincluding 1 x 18 w ledretrofitbar professional cw 6500 k cover channel, bipin holders, led power driver, connector block, etc complete with all accessories internally prewired and including connecting up with three core flexible copper conductor cable with suitable size for connection of fitting from ceiling rose complete all as specified and directed. make : havells cat part no photonultra2.01212t8sstl20wled 865spc ( for tube ) regalbattent8upto1x22wdsbswh ( for batten ) bajaj cat part no blrb 18w cwc for tube , blrb db 118 for batten , or equivalent model of philips / crompton 50 supply and fixing led light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 v ac decorative type with driver holder and led lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.make : bajaj / havells / cg 51 s & f led light fitting 1x10wbulkhead luminaires including led light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.make : bajaj / havells / cg 52 supply and fixing testing and commissioning energy saving street light luminaire 35 watt led , pressure die cast housing with epoxy powder coated with colour finish and prismatic poly carbonate coverlic cover complete, ip 66 protection incl connecting with three core copper flexible wire from ceiling rose to connector of light fitting complete all as specified and directed by engr in charge. make havells cat part no enduracityliteplat plussl35wled757sasybopc or equivalent model ofsurya / control& switchgear / bajaj 53 supply and fixingstreet light bracket made of 32 mm gi pipe , 1.2 mtr lenght fixed withtwo nos of clamp , nut and bolts for fixing of street lightcomplete all as specified and directed by engr in charge. 54 s & f of mcb sp, 240 volt, 6 amp to 40 amp capacity, 10 ka, c curve complete all as specified and directed. 55 s & f of mcb spn, 240 volt, 63 amp capacity, 10 ka, c curve complete all as specified and directed. 56 s&f of mcb distribution board single pole & neutral with 200 amps rated bus bar, double door ip 43 dbs , made outof sheet steel enclosure, recessed type, factory made powder coated 8 way, 240 volts suitable for housing mcbs including blanking platecomplete all as specified and as directed by the engineer in charge. 57 s&f exhaust fans ac single phase 230v of size 300mm sweep with louver including connecting with three core flexible copper wire from ceiling rose to connector of fan complete all as specified and directed.make : usha / crompton / bajaj 58 m&l for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate at a depth not less than 1.5m below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and other end of earth wire connected to main switch board and protected by galvanised iron pipe light grade 15mm bore and water pipe 20 mm bore gi med grade with funnel and wire mesh pcc chamber in cement concrete 1:3:6 type c 2 and rcc cover with handle all as specified and shown in elect plate no 3 of ssr part i of 2009 incl dismantling of old unserviceable existing earthing complete all as specified and as directed by the engineer in charge. 59 s&f of led lamp 9 / 10 watt complete all as specified and as directed. make : havells / crompton / bajaj / usha 60 supply & fixing ceiling fan 1200 mm sweep , 230 volts, ac , 50 hz, copper winded motor, bee 5 star rated white colour complete with motor, blade set of three nos , down rod, canopy, shackle assy complete all as specified and as directed.make: crompton / havells / orient 61 s&f single pole and neutral enclosure with a two pin and earth plug and earth plug and socket complete with one single pole 20 amp mcb sp c series for ac complete all as specified and directed. 62 supply, laying and testing cable xlpe insulated , screened, pvc bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and as directed by the engineer in charge. 63 supply and fixingtubes light grade gi tubing 40 mm dia withall fitting laid in trenches, fixed on pole / on wall for cable protection complete all as specified and as directed by the engineer in charge. 64 excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft / loose soil complete all as specified and as directed. 65 returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft / loose / hard / dense soil complete all as specified and as directed. 66 removing excavated material ( soils ) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point 67 supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed.note: depth of sand cushioning will be measured after punning down and levelling the sand properly. 68 m&l for laying of bricks locally available sub class b bricks, non modular sizes as per is 1077: 1992 for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable all as directed. 69 total in figures 70 quoted amount in words...

Department Of Local Bodies - Rajasthan

33944981 supply and fixing of decorative poles in kamla nehru garden at muniicpal board mount abu supply and fixing of decorative poles in kamla nehru garden at muniicpal board mount abu , providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed armoured aluminium cable of 1.1 kv grade as per pwd specification for electrical works in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points ( a ) , ( b ) , ( c ) , mentioned below: ( a ) material : h4 grade aluminium conductor of purity >99.6 % & as per is:1554 p i / is :7098 p – i ( b ) conductor shall have electrolytic aluminium confirming to is 8130, is 3975 1999 for armouring of cables in armoured cable items , is 5831 for sheath, is 10810 ( part 0 to 64 ) for testing procedures. ( c ) oem must have iso 9001 & 14001 certifications for quality assuarance & its own in house nabl lab setup for all testing facilities for cables . appropriate type test certificate / oem test report shall be submitted . all above as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr. 6.0 sq. mm4 core , supply & laying following size earth wire in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection with gi / cu thimble etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 10 swg g.i. ( hot dipped ) wire , supply & laying following size b class , medium class g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor / strip / cable in ground / surface / recess as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 50 mm dia , providing & laying of double wall corrugated pipe confirming to is : 14930 p 1 & 2 with hdpe coupler at 1 mtr. depth below the ground for laying cable including making the trench and back filling , compaction of earth as required ( excavation of earth to be paid extra as required. ) of following outer dia. / inner dia as per is:4984:1995. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 55 / 50 mm , labour charges for excavation of 30cmx75cm size trench in cc road including refilling of excavated earth, compaction of earth, making good the same complete as required . , labour charges for excavation of 30cmx75cm size trench in loose soil including refilling of excavated earth, compaction of earth, making good the same complete as required . , plate earthing as per pwd specification for electrical works as per is:3043 with hot dipped g.i. earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. g.i. b class watering pipe , including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke / charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . , providing & fixing of 240 / 415 v ac mcb with positive isolation of breaking capacity not less than 10 ka ( b / c tripping characteristic as per type of load and site requirement ) 4kv impulse withstand voltage, as per pwd specification for electrical works with isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , ip 20 contact protection and fitted with existing distribution board / sheets, min. operation 20, 000 upto 32 a rating and 10, 000 upto 63 a, 5000 for 80 a rating including making connections, testing etc. as required. . oem shall have submit nabl / cpri / erda accrediated lab test reports before execution & all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . single pole mcb 06 amp rating , four pole mcb 32 amp rating , providing & fixing of ac operated heavy duty 230 / 440 volt power contactor as per pwd specification for electrical works, isi marked is / iec 60947 4 1 : 2000 having provision of mechanical interlocking, auxilary contacts, din rail mounting type including making connections, testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 4 pole power contactors with following ac 1 rating 32 amp. , supplying and fixing of aluminium ( iec 60105 iso 209 1, 2 ) / copper ( iec 60028 ) bus bar as per pwd specification for electrical works, by means of smc / dmc type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . electrolytic grade ( cu etp ) tin coated annealed copper bus bars iacs 100% grade , sitc of wall / free standing floor mounted dust and vermin proof compartmentalised cubical panel as per pwd specification for electrical works, made out of crca sheet . other parameters required as per point ( a ) , ( b ) , ( c ) , ( d ) below: ( a ) thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. load bearing structure shall be of 2.0 mm thick sheet supported by base m.s. channel if required . side walls and cable alley compartments having bolted type doors with / without detachable extension type structure ( b ) panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade the panel having pu / neoprene rubber gasket of not less than 3mm thickness , required hardware, separate detachable gland plate m.s. base channel ( min75mm ) , hinged door with locking arrangement for equipment / switchgear. ( c ) interconnection between bus bar and switchgears / cable shall be rigidly supported and made out by flexible copper wires ( up to 125 amp ) and by solid bus bar ( >125 amp ) . all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( d ) only outer area on all sides shall be measured & panel to be fabricated only from cpri approved fabricator. all as per drawing pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . , providing & fixing of 110 240 v, ac, 1 ph. , 2 w astronomical time switch with surge suppressor, memory card, sunrise / sunset selectable, software for programming including making connection, etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . , supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from 99.99% purity copper, class 5 stranding in acc. to iec 60228 for lower watt loss , oxygen free ( <10 ppm ) for less chances of oxidization and higher silver content for gives better conductivity , insulation pvc type a or c , flame retardant as per is 10810 53, better amperage rating as per vde 0298 part 4, , in existing surface or recessed pvc / ms conduit / casing capping including all as per pre approved by engineer in charge, making connections, etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of products / work , refer annexure a attached with this bsr . 2 x 1.5 sq.mm , 3 x 2.5 sq.mm , 1 x 4.0 sq.mm , providing & fixing of ik07 ip 66 protected high power led floodlight system with pressure diecast aluminium housing lm6 / adc12 material , toughened glass diffuser with suitable lenses on led to achieve various beam angles, 240 volt, 50hz, of high power led lamps . integrated driver must be potted & has a unique bis r number shall be high efficiency having efficiency more than 85 %and in compliance to bis certified and t.c. certificate. the system level luminaire efficacy >=120 lm / wt with high power leds is to be used . led driver input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety . input frequency 50hz±3%, power factor >0.95 , driver efficiency >85% , thd ( i ) <10% , driver current <1000ma shown in lm79 report. driver should be phase to phase protection of 440 v for 4 hrs. electrical connector must be provided, surge protection min >=4kv internaland 10kv external, system life of 30000 burning hours with 70% ofinitial lumens maintained, color rendering index >70 and cct 5700k±355k. driver current <1000ma shown in lm79 report. manufactures word mark / name engraved / embossing / screenprinting on die cast housing to allow traceability / authenticity. fixture shall be is 10322 complianced. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 / lm80 ) certificate / report withliable warranty of product / accessories from oem shal be submitted.all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . high power led flood light 200w...

Department Of Local Bodies - Rajasthan

33561804 the work of installing poles and cables etc. at dholabhata area. 1 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed unarmoured / armoured aluminium cable of 1.1 kv grade as per pwd specification for electrical works in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points ( a ) , ( b ) , ( c ) , mentioned below: ( a ) material : h4 grade aluminium conductor of purity >99.6 % & as per is:1554 p i / is :7098 p – i ( b ) conductor shall have electrolytic aluminium confirming to is 8130, is 3975 1999 for armouring of cables in armoured cable items , is 5831 for sheath, is 10810 ( part 0 to 64 ) for testing procedures. ( c ) oem must have iso 9001 & 14001 certifications for qualityassuarance & its own in house nabl lab setup for all testingfacilities for cables . appropriate type test certificate / oem test report shall be submitted . all above as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr. armoured cable10.0 sq.mm 4 core 2 supply & laying following size b class , medium class g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor / strip / cable in ground / surface / recess as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr 50 mm dia. 3 80 mm dai 4 32 mm dia hdpe pipe pn 6 ( class pe 80 5 earth work in excavation for roadway, including trimming bottom and side slopes in accordance with requirement of line, grades and cross sections, including disposal of surplus material with all lift and lead upto 1000 metre as per mort&h specification clause 301. in ordinary rock 6 supply & laying following size earth wire in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection with gi / cu thimble etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 8 swg g.i. ( hot dipped ) wire 7 supply and erection of m.s. galvanized octagonal pole ( as per bsen 40 3 3:2003 / bsen 10025 / is 2062 is:875 part 1 – 2015 / for ms plate for base flange ) of following length and dimension as per table p 01 with base plate on the cement concrete foundation of m 20 grade ( 1:1.5:3 ) as per is 456 / is 2911. with the help of anchorbolts of grade 6.8 ( is: 1367 p iii ) . the pole shall have aweatherproof flush door and locking arrangements. complete in all respect. all as per pre approved by engineer in charge. foradditional technical parameters of products / work , refer annexure a attached with this bsr .octagonal ms poles made of s 355jo grade steel sheet , folded lengthwise to obtained octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with is 2629. ( see table p 01 for specs. ) 8 mtr. 8 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works withisi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wireshould be made from 99.99% purity copper, class 5 stranding inacc. to iec 60228 for lower watt loss , oxygen free ( <10 ppm ) forless chances of oxidization and higher silver content for gives betterconductivity , insulation pvc type a or c , flame retardant as per is10810 53, better amperage rating as per vde 0298 part 4, , inexisting surface or recessed pvc / ms conduit / casing cappingincluding all as per pre approved by engineer in charge, makingconnections, etc. as required. oem must have its own in housenabl lab setup for all testing facilities for wires. for additionaltechnical parameters of products / work , refer annexure aattached with this bsr . 2 x 1.5 sq.mm 9 providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering all work upto plinth level :1:5:10 ( 1 cement : 5 fine / coarse sand : 10 graded stone aggregate 40 mm nominal size ) 10 providing & fixing of 240 / 415 v ac mcb with positive isolation of breaking capacity not less than 10 ka ( b / c tripping characteristic as per type of load and site requirement ) 4kv impulse withstandvoltage, as per pwd specification for electrical works with isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec60947 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , ip 20 contact protection and fitted with existing distribution board / sheets, min. operation 20, 000 upto 32 a rating and 10, 000 upto 63 a, 5000 for 80 a rating including making connections, testing etc. as required. . oem shall have submit nabl / cpri / erda accrediated lab test reports before execution & all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . single pole mcb6 a to 32 a rating...

Department Of Local Bodies - Rajasthan

33561762 the work of installing poles and cables etc. at ajay nagar road 1 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed unarmoured / armoured aluminium cable of 1.1 kv grade as per pwd specification for electrical works in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points ( a ) , ( b ) , ( c ) , mentioned below: ( a ) material : h4 grade aluminium conductor of purity >99.6 % & as per is:1554 p i / is :7098 p – i ( b ) conductor shall have electrolytic aluminium confirming to is 8130, is 3975 1999 for armouring of cables in armoured cable items , is 5831 for sheath, is 10810 ( part 0 to 64 ) for testing procedures. ( c ) oem must have iso 9001 & 14001 certifications for qualityassuarance & its own in house nabl lab setup for all testingfacilities for cables . appropriate type test certificate / oem test report shall be submitted . all above as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr. armoured cable10.0 sq.mm 4 core 2 supply & laying following size b class , medium class g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor / strip / cable in ground / surface / recess as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr 50 mm dia. 3 32 mm dia hdpe pipe pn 6 ( class pe 80 4 earth work in excavation for roadway, including trimming bottom and side slopes in accordance with requirement of line, grades and cross sections, including disposal of surplus material with all lift and lead upto 1000 metre as per mort&h specification clause 301. in ordinary rock 5 supply & laying following size earth wire in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection with gi / cu thimble etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 8 swg g.i. ( hot dipped ) wire 6 supply and erection of m.s. galvanized octagonal pole ( as per bsen 40 3 3:2003 / bsen 10025 / is 2062 is:875 part 1 – 2015 / for ms plate for base flange ) of following length and dimension as per table p 01 with base plate on the cement concrete foundation of m 20 grade ( 1:1.5:3 ) as per is 456 / is 2911. with the help of anchorbolts of grade 6.8 ( is: 1367 p iii ) . the pole shall have aweatherproof flush door and locking arrangements. complete in all respect. all as per pre approved by engineer in charge. foradditional technical parameters of products / work , refer annexure a attached with this bsr .octagonal ms poles made of s 355jo grade steel sheet , folded lengthwise to obtained octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with is 2629. ( see table p 01 for specs. ) 8 mtr. 7 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works withisi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wireshould be made from 99.99% purity copper, class 5 stranding inacc. to iec 60228 for lower watt loss , oxygen free ( <10 ppm ) forless chances of oxidization and higher silver content for gives betterconductivity , insulation pvc type a or c , flame retardant as per is10810 53, better amperage rating as per vde 0298 part 4, , inexisting surface or recessed pvc / ms conduit / casing cappingincluding all as per pre approved by engineer in charge, makingconnections, etc. as required. oem must have its own in housenabl lab setup for all testing facilities for wires. for additionaltechnical parameters of products / work , refer annexure aattached with this bsr . 2 x 1.5 sq.mm 8 providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering all work upto plinth level :1:5:10 ( 1 cement : 5 fine / coarse sand : 10 graded stone aggregate 40 mm nominal size ) 9 providing & fixing of 240 / 415 v ac mcb with positive isolation of breaking capacity not less than 10 ka ( b / c tripping characteristic as per type of load and site requirement ) 4kv impulse withstandvoltage, as per pwd specification for electrical works with isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec60947 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , ip 20 contact protection and fitted with existing distribution board / sheets, min. operation 20, 000 upto 32 a rating and 10, 000 upto 63 a, 5000 for 80 a rating including making connections, testing etc. as required. . oem shall have submit nabl / cpri / erda accrediated lab test reports before execution & all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . single pole mcb6 a to 32 a rating...

Military Engineer Services - Rajasthan

33552074 provision of certain sanction works under ge a central jodhpur 1 excavation over areas not exceeding 1.5m in deep and getting outin any type of soil complete all as specified and as directed. 2 removingexcavated soil to a distance exceeding 250 mtr andnot exceeding 500 mtr and depositing where directed at a level not exc. 1.50 m complete all as specified and asdirected. 3 returning, filling in, excavated material, including spreading , leveling , watering and well ramming in layer n. exc 25 cm complete all as specified and as directed. 4 m&l for 100mmthick ( spread thickness ) soling with crushed or broken boulders or quarried stone of grading 2 ( 63 to 90 mm size ) spread and leveled interstice filled, surface formed and rolled and consolidated to required gradient and camber with 8 to 12 tone power roller, complete all as specified and directed by engr in charge. 5 m&l for 150 mm thick ( compacted thickness ) wbm in 2 layers of 75 mm thick ( each layer to be rolled and consolidated separately with coarse aggregate of grading 2 ( 63 to 40 mm size ) of sand stone, flint or quartzite spread, and rolled, consolidated to required gradient and camber with power roller of 8 to 12 tonne capacity, complete all as specifiedand directed by engineer in charge. 6 m&l for 200 mm thick ready mix cement concrete work in pavement / hard standing of flexural strength 40 kg / per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less, complete all as specifiedand directed by engineer in charge. 7 m&l for stone sett flooring with granite ( jallore stone ) stone setts of size 200 to 250mm long, 150 to 200mm wide and 150mm deep and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush, complete all as specifiedand directed by engineer in charge. 8 m&l for edge stones to flooring with stone setts of size 250 to 300mm long x 150 to 200mm wide, and 500mm deep andand sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush, complete all as specifiedand directed by engineer in charge. 9 supply, fixing, testing & commissioning of advanced ese lightening protection system including opr lightning conductor, lightning stroke counter, surge protective device, protecting flat, test point, stainless steel clips, coupling accessories, hooks, duck foot connector, equipotential box, protecting flat, extension mast, conductor supporting stud etc for building, as per site requirement and directed by engr in charge 10 earthing complete withgalvanised earth plate electrode 600cmx600cmx6.0mm thick, buried directly in ground ( earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.50 mtr below normal ground level connected with galvanised iron earth strip 32x6mm by means of bolts, nuts, check nuts and washer of galvanised iron or steel complete with 40 mm dia gi light grade protection pipe, 20mm dia gi medium grade watering pipe with funnel including charcoal, dust, salt, pcc m 15 type b1 in pit with angle iron ( 25x25x3 ) mm frame work with precast rcc 1:2:4 type b 1 cover reinforced with 8mm dia tmt bars @ 150mm c / c both ways and 12mm dia ms fabricated handle, test piont etc. in and including light grade gi protection pipe 40mm bore up to 5m lenght for drawing in earth lead wire , all as shown in electrical plate no.3of ssr part 1 complete with necessary earth work in any type of soil, removal to a distance not exc. 50m, testing on completion complete all as specified & directed. 11 supply, fixing, testing & commissioning of air termination aluminium rod 12mm dia and 300mm long, single pointed, fitted on the roof top and jointing with the aluminuim strip, including pcc work 1:2:4, complete all as specified and as directed by engg in charge. 12 test point terminal block made of gun metal or phosphorous bronge 75 x 75 x 25mm of 6mm thickness drilled and screwed including 3 nos 8mm dia 25mm long hexagonal head brass screws including box of size 90 x 90 x 90mm made of 1.6mm plain sheet and screwed to wall for protection of test point completed all as specified. 13 m & l for aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground and connected to earthing sys, complete in all respect and entire satisfication of engr in charge. 14 supply and fixing of gi strip 32 x 6mm fixed with saddles & fixing screws, pvc dash fastners, insulators fixed from test point to earth on walls or burried in ground / drawn into hume pipe, complete all as specified and as directed by engg in charge. 15 m & l for gi tubing, light grade, 20 mm bore with fitting & fixing along wall with suitable size clamps complete all as specified including pcc work 1:2:4, complete all as specified and as directed by engg in charge. 16 supply, installation, testing & commissioning of 1.50 ton split ac, 5 star rating, with cordless remote control unit, inclding air ionizer and plasma filter for better indoor air quality with energy efficient with 2.0 kvar stablizers copper wound voltage range from 170 v to 280 v, complete all as per specified & directed by engg. in charge.make:ogeneral / hitachi / daikin as approved by ge. 17 supply, installation, testing & commissioning of sub main wiring with two runs of pvc insulated but unsheathed multi stranded copper conductor frlsh cable 1100 volt grade of size 4 sqmm and one run of 4 sqmm single core pvc insulated but sheathed multi stranded copper conductor frlsh cable ( phase red, neutral black, earth green ) 1100 volt grade as earth lead drawn through in and includingpvc casing& caping surface mounting, etc fixed in wall or ceiling etc., complete all as specified and as directed by engr in charge.note: two runs of 4.00 sqmm cable with one run of 4.00 sqmm earth wire and pvc casing & caping shall be measured & paid for as one length. 18 m&l writing letters in black colour paint following details in letters40 mm width, complete all as specifed & directed by engg. in charge. ( a ) manufacturer sl. no.________________ ( b ) ca no.______________________________© actual date of completion:___________________ ( d ) intial cost____________________________ ( e ) prb page no.___________________________ ( f ) location: __________________________________ ( g ) mes sl. no._____________________________ 19 m&l for metal clad box complete withmcb single pole 230 volts rating from 20 amps, with rupturing capacity 10 ka, c curve type, with over load and short circuit protection, complete all as specified and as directed by engg. in charge. make : legrand / abb / schneider 20 supply, installation, testing and commissioning in existing location and position refrigerator, digital panel, electric driven, single phase having approx storae and nominal cooling capacity310 ltrs, frost free inverter, ag clean technology, using eco friendly gas , minimum bee 5 star rated and above complete with all acessories as per manufacturer.make : bluestar / bosch / samsung 21 supply, installation and testing in existing location and position, metal top deep freezer, chest freezer, double door, size 1180mm x 665mm x 830mm, cfc free insulation, sunken handle, electric driven, single phase, having approx storage and nominal cooling capacity 320 ltrs, bee star rating 3 star and above rated.make : bluestar / bosch / samsung. 22 supply, installation and testing in existing location and position, metal top deep freezer, chest freezer, double door, cfc free insulation, sunken handle, electric driven, single phase, having approx storage and nominal cooling capacity 405 / 425 ltrs.bee star rating 3 star and above rated, complete all as specified and as directed. make : bluestar / bosch / samsung. 23 supply and fixing ceiling fans with blades, down rods, electronic regulator and accessories, 230 v, 1200 mm sweep, min air delivery 210 cfm with service value 6.00 bee, 5 star rated with brushless direct current motor ( bldc ) connecting upwith and including three core flexible pvc insulated multi stranded copper condutor of size 1.0 sqmm from ceiling rose / conector to fan ( earth wire to connected to fan hook ) , isi marked, complete all as per directed and specifed make : havells / orient / usha. 24 supply, installation, testing and commissioning ofwindow type air conditioner electric driven ( single phase ) , cooling capacity 4500 k cal per hour ( 1.5 ton ) complete with cordless remote control unit and with in built air ionizer and plasma filter for better indoor air quality with minimum bee 5 star rating or above energy efficient complete with 3.0 kva stabilizer copper wound with voltage range from 170v to 280 volt complete all as specified and as directed.make: mitsubishi / ogeneral / daikin 25 m&l for point wiring complete with 1.5 sq mm single core pvc insulated but unsheathed multistranded copper conductor fr lsh cable1100 volts grade drawn through and including non metallic rigid pvc heavy duty concealed conduit with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes, etc fixed concealed / recessed in wall or ceiling etc including 1.5 sq mm, single core, pvc insulated but unsheathed multi stranded copper conductor fr lsh cable ( green ) 1100 volts grade as earth continuity wire connected to earth dollyand including modular sunken galvanized terminal boxes of same make of switch / socket / regulator withsleek and curvy cover plates, for mounting ofmodularswitches, sockets, fan regulators complete for the following, complete all as specified and as directed : ( a ) one light / fan / bell point controlled by one, one way switch. 26 s&f modular switch 1 way 6 amp, 1 module, single pole complete all as specified and as directed.make :legrand / abb / schneider 27 s&f ceiling rose surface bakelite 3 terminals 230 volts ac with polycarbonate body, complete all as specified and as directed by engineer in charge. make : anchor / legrand / havells 28 s&f exhaust fan, heavy duty steel body, ac single phase 300 mm sweep complete with louvers including cutting / making holes in wall fixing / grouting of frame & connecting with & including 3core pvc insulated copper conductor flexible cable of size 23 / 0.0076 ( or eq. size in mm ) from ceiling rose to fan, complete all as specified and as directed by engg. in charge.make : havells / bajaj / usha 29 note: 10 nos sanction jobs quantities are clubbed in this boq, which is detailed in the annexure i on sl. page no. 23 of tender document. therefore, the work and its measurement should be completed keeping in view the annexure i....

Military Engineer Services - Rajasthan

33421946 provn of clothing and medical store at army area under ge shikargarh jodhpur excavation in trenches n.exc 1.5 m wide & n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in soft / loose soil complete all as specified and as directed. 2 m&l pcc 1:4:8 type d2 ( 40 mm graded aggregate ) in foundation filling and mass concreteetc complete etc.all as specified and as directed. 3 m&l for brick work with fly ash bricks ( old size bricks ) , straight or curved on plan exc 6mtr mean radius, built in cement mortar ( 1:6 ) complete all as specified and as directed. 4 m&l for form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides of soffits ( if any ) of foundations and plinth beams and similar work etc; rough finish surfaces complete all as specified and as directed. 5 m&l for form work to sides of concrete pillars, posts, struts, piers, columns and stanchion etc; rough finish surfaces complete all as specified and as directed. 6 m&l for form work to sides and soffits of floor or roofrcc beam sides of lintel beam flat rough finish surfaces to receive the plaster, complete all as specified and as directed. 7 m&l for formwork for chullah hoods, chajjas through and similar items including edges, surface rough finish surfaces to receive the plaster, complete all as specified and as directed. 8 m&l for form work to soffits of suspended slabs such as roof slabs, landings and similar work; not exceeding 200mm thick ( horizontal or sloping ) , rough finish surfaces complete all as specified and as directed. 9 m&l for form work to edges of concrete flats, floor and roofs not exceeding 20cm wide ( horizontal or sloping ) , rough finish surfaces complete all as specified and as directed. 10 m&l for providing rcc 1:1 1 / 2:3 type b1 ( using 20mm graded stone aggregate ) as in foundations, including raft footings, foundations beams, plinth beams, bases of columns etc; complete all as specified and as directed. 11 m&l for providing rcc 1:1 1 / 2:3 type b1 ( using 20mm graded stone aggregate ) as in columns, pillars, piers, posts and struts etc; complete all as specified and as directed. 12 m&l for providing rcc 1:1 1 / 2:3 type b1 ( using 20mm graded stone aggregate ) as in beams, lintel up to 1.5m clear span, lintel bands etc; complete all as specified and as directed. 13 m&l for providing rcc 1:1 1 / 2:3 type b1 ( using 20mm graded stone aggregate ) as in slabs supported on walls, beams and columns in roof, landings, balconies, canopies and in shelves etc; complete all as specified and as directed. 14 m&l for providing rcc 1:1 1 / 2:3 type b1 ( using 20mm graded stone aggregate ) as in chajjas etc; complete all as specified and as directed. 15 m&l for reinforcement 10mm dia and over tmt bars cut to length, bent to shape required and binding with ms wire not less than 0.9mm dia or securing with clips complete all as specified and as directed. 16 m&l for reinforcement 8 to 10mm dia tmt bars cut to length, bent to shape required and binding with ms wire not less than 0.9mm dia in stirrupscomplete all as specified and as directed. 17 m&l for carrying out water proofing treatment forroofs in the following stages ( i ) rendering 10mm thick in 1:4 mixed with integral water proofing liquid all as per manufacturers instructions over concrete surfaces finished even and smooth with out using extra cement. ( ii ) first coat of bitumen primer confirming to is 3384 @0.300 kg / sqm over plastered surafces ( iii ) secondlayer of 3.0 mm thick app modified polymeric membrane with centre core of single non woven polyster reinforcementandhaving weight 3 kg / sqm with mineral gravel finish on top complete laid with blown type bitumen grade 85 / 25 @ 1.20 kg / sqm complete all as specified and as directed. ( iv ) finally applying two protective coats of bituminous aluminium based reflective paint to safeguard against uv, including preparing of old surfaces of roof remove all corrosion products brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots incl washing , rubbing down and stopping of painted surfaces ( second coat apply after 24 hrs or as per manufacturing instructions ) . 18 supply only integral water proofing liquid isi marked make: pidiproof lw 19 returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm each layer in hard / dense soil all as specified and directed. 20 removing excavated soil n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point all as specified and directed. 21 m&l for 15 mm thick rendering on stone / brick masonary wall surfaces in cm 1:4finished fair and even all as specified and as directed. 22 m&l for rendering 15 mm thick in cm 1:6 finished even without using extra cement over stone wall surfaces all as specified and as directed. 23 m&l for 10mm thick rendering in cm 1:3 on ceiling surfaces finished surfaces even and smooth without using extra cement complete all as specified and as directed. 24 m&l for 75mm thick pcc 1:4:8 type d 2, ( 40mm graded stone aggregate ) as in sub floor, sub bases, floor and paving etc; complete all as specified. 25 m&l for pcc 1:2:4 type b0 25 mm thickusing 12.5mm graded stone aggregates as in sub floors / base floors under tiles as in levelling course etc all as specified and directed. 26 m&l for machine cut kota stone slab flooring 18 20 mm ( + 2mm ) thick over cement screed base laid and jointed with greycement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over and including 15mm thick screed bed or bedding layer in cm 1:4 complete all as specified and as directed. 27 m&l for mirror polished machine cut kota stone slab 15 16 mm thick in riser of steps, skirting, dado and pillar laid over and including 10mm thick rendering in cm 1:4 and jointed complete all as specified and as directed. 28 m&l for 16 18mm thick granite ( colour as approved ) work ( table rubbed and polished ) in steps, shelves, jambs, pillars, window cills, cooking platforms ( vertical / horizontal ) and like in cement mortar ( 1:4 ) including pointing in white cement ( 1:2 ) using marble dust with admixture of pigment to match with shade of granite over and including 10mm thick screed bed or bedding layer in cm 1:4 complete all as specified and as directed. 29 cement concrete ( 1:2:4 ) type b 1 using 20 mm graded stone aggregate as in plinth protection, 50 mm thick, surfaces finished even and fair without using extra cement including provision of construction joints complete all as specified. 30 pressed steel framed made out of 1.25mm thick ms sheet, of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, complete all as specified and directed. 31 cement concrete ( 1:3:6 ) type c 1 using 20 mm graded stone aggregate as in fillings and mass concrete, filling backs of chowkats etc., complete all as specified 32 cement concrete ( 1:2:4 ) type b 1 using 20 mm graded stoneaggregate as in lintels upto 1.50 m clear span, cills , steps, seismic and other similar bands, copings, kneelars, apex stones, bed plates, bedblocks of hold fasts etc including necessary form work complete all as specified 33 s&f of factory made 35 mm thick plain framed, panelled shutters ( two panel ) with 2nd class hard wood rail and stylewith lock rail and panel of 9 mm b.w.p. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. the size of rail and stile as per is : 1003 ( part i ) , kiln seasoned and chemically pressure treated complete all as specified. 34 s&f of factory made steel window box type using erw hollow p section comprising double frame for and including gauged and glazed skeleton shutter jointed internally with flat iron 40x4mm complete including grill of 8 / 10mm square bars as directed by engineer incharge, fixed horizontally @ 10cm c / c, hinges, handle, tower bolts, stops, lugs etc. ( with provision of fixing for cooler if required ) all as shown on drawing no cejz / td / 20 sheet 1 / 3 to 3 / 3 fixed in repairs i.e, incl taking down and removal of old steel windows from site or to store complete all as specified and directed. note: guard bar / grillshall be measured and paid separately under respective item of sch a. 35 s&f of sheet glass ordinary quality 4 mm thick and glazing with oil putty or fixed with wooden beads or fixed with rubber gasket in squares any size of pane complete all as specified & as directed. 36 mild steel round bars welded to steel windows or ventilators as in guard bars framed or unframed complete all as specified & as directed by engineer incharge.note: guard bars shall be factory welded & given one shop coat of red oxide or zinc chromate primer. cost of factory welding & shop coat of primer is deemed to be included in quoted rates. 37 s&f mild steel door handles, stove enameled black, 150 mm long and fixed with steel screws complete all as specified. 38 s&f of mild steel barrel tower bolts, stove enameled black, with bright bolt, 150 mm long and fixed with steel screws complete all as specified. 39 s&f of 300 mm long mild steel, sliding door bolt, plate type, stove enameled black, with bright bolt not less than 12 mm dia with and including bolts and nuts complete all as specified. 40 s&f of framed work as in doors chowkats of ms angle iron or ms hollow square / rectangular any type / size with gusset plates, rails, braces, cooler stand, chajja framed complete drilled for fixing of door etc; to be prepared for hanging with and including hold fasts and locking arrangements confirming to fe 290 ( gde e 165 ) complete all as specified and directed by engineer in charge. 41 m&l for 100mm thick pcc 1:4:8 type d 2, ( 40mm graded stone aggregate ) as in sub floor, sub bases, floor and paving etc; complete all as specified. 42 m&l for 60mm thick factory made pre cast cement concrete rubber moulded laquer finish using chemical and admixure inter locking tiles having compressive strength not less than 350 kg / sqcm, of shape and colour as approved by ge , laid over 25mm thickcompacted approved sand cushioned surface, joints filled by fine sand and compacting the top surfaces of paver blocks after laid etc of approved make all as specified and as directed. 43 m&l for factory made precast cement concrete solid blocks m 30 grade, using 20 mm graded crushed stone aggregate as in kerb stones of any size ( with plain or interlocking joints as directed ) set in cement mortar 1:4 for path edgings etc; embedded in position including all necessary excavation, tamping ground arround blocks and removal of rubbish / surplus soil etc., complete all as specified and directed by engineer in charge. 44 m&l for cement concrete ( 1:2:4 ) type b 1 using 20 mm graded stone aggregate as in kerbs or benching etc including necessary form work complete all as specified. 45 preparing new plastered surfaces and m&l for applying chalk whitening / concrete primer and / or cement base putty as required incl preparing the surfaces smooth by rubbing and / or sandpapering and m&l two coats of distemper oil emulsion on new plastered surfaces all as directed by engr in charge. 46 preparing new plastered surfaces and m&l for applying concrete primer and / or cement base putty as required incl preparing the surfaces smooth by rubbing and / or sandpapering and m&l two coats of cement base paint on new plastered surfaces all as directed by engr in charge. 47 preparation of newplastered surfaces of ceiling etc. & applying three coats of limewhite wash on ceilingcomplete all as specified. 48 preparing new or previously untreated surfaces of wood and wood based material of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed. 49 preparing new or previously untreated surfaces of steel or iron work of any description and girth over 10cmand applying two coats of synthetic enamel paint complete all as specified andas directed by engineer in charge.. 50 m&l for point wiring ( concealed ) one light / fan point controlled by one 5 amps one way switch with 1.5 sqmm ( nominal area ) copper conductor flame retardant low smoke cable ( multi stranded ) pvc insulated and unsheathed electric cable 1100 volts ( isi marked ) drawn through pvc concealed conduit of suitable size ( as per conductor run ) with all fittings and accessories including pvc insulated unsheathed electric cable 1100 volts 1.5 sqmm ( multi stranded ) copper conductor single core ( green colour ) as continuous earth wire connected to common earth dolly including metal flush box made out of ms with hylum sheet suitable size and shape complete all as specified and directed by engineer in charge.. 51 all as per item no 50 above but for one 3 pin socket outlet 5 amps on independent board 52 all as per item no 50 above but for one 3 pin socket outlet 5 amps on same board 53 all as per item no 50 above but for one 3 pin socket outlet 15 ampsindependent with cable of size 4.0 sqmm for point wiring and 4.0 sqmm in continuous earth wire complete all as specified and directed by engineer in charge. 54 s & f switchpiano type 1way5a, 1 module 240 volts complete all as specfied and directed by engr in charge. 55 s & f switchpt 1way15a, 1 module, 240 volts complete all as specfied and directed by engr in charge. 56 s & f socket, 6a 2 / 3 pin combined 2 module, complete all as specfied and directed by engr in charge. 57 s & f socket6a / 16a 2 / 3 pin combined 2 module, complete all as specfied and directed by engr in charge. 58 s & f lamp holder, pvc / polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by engr in charge. 59 supply and fixing led lights fitting 1x 18w, 220v ac, metal ray plus is made of extruded aluminum channel with decorative dual color end caps providing a glare free evenly distributed light with driver, holder including led tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. 60 supply and fixing led street light fitting 35 watt 230 v ac outdoor type with pressure die cast housing with toughned glass ingress protection of ip66, high power smd leds and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete all as specified. 61 ceiling rose surface backelite isi marked with 3 terminalincluding connecting and testing complete all as specified and dirted by the engineer in charge. 62 s&f distribution board sheet encloser powder coatedfor mcbs with bus bar 250 amps rated and neutral link earthing stud and degree of protection ip43 with door / mechanical resistance ik 07, spn 8 way 240 volts double door, concealed flush to wall surface complete all as specified and directed by the engineer in charge. 63 s&f distribution board sheet encloser powder coatedfor mcbs with bus bar 250 amps rated and neutral link earthing stud and degree of protection ip43 with door / mechanical resistance ik 07, spn 4 way 240 volts double door, concealed flush to wall surface complete all as specified and directed by the engineer in charge. 64 s& mcb, c curve type, 10 ka, 6 to 32 amp, single pole with over load and short circuit protection, complete all as directed. 65 s&f mcb, c curve type, 10 ka, 40amp, spn with over load and short circuit protection, complete all as directed. 66 supply and fix exhaust fan, steel body ac single phase. 230v of size 300m sweep with, blades, and frame and louvers with necessary making hole and finishing work as reqd at site complete all as specified and directed. 67 supply and fixing ceiling fans complete with blades, down rods, with 2 module electronic step type regulator and accessories, 230 v, 1200 mm sweep. min air delivery 210 cfm with service value 6.00 bee. 5 star rated with brushless direct current motor ( bldc ) compele all as specified and directed. 68 s&f vertical distribution board, double door, suitable for a frame fp mccb 125a made out of crca mild steel sheet surface with insulated material like polyester or with epoxy powder coating, vtpn 4 way, 415 volts with bus bar rating 250 amps, dust and vermin proof, suitable for incorporation of mcb’s and mccb etc and making all necessary connections, concealed flush to wall surface, complete all as specified and directed. note : mccb & mcb will be measured and paid separately under respective items 69 s&f mccb, a frame, thermal adjustable magnectic setting, ics = 75% 25 ka, 415v, 125 amp, 4 pole mccb with over load and short circuit protection, complete all as directed. 70 supply and fixing concealed sub main wiring with 2x10 sqmm single core copper conductor ( multistandered ) in concealed pvc frls conduit of suitable size as required, including single core 6.0 sqmm copper conductor as earth continuity all as directed. 71 supply, laying, testing and commissioning of lt ug cable, xlpe insulated, pvc sheathed, galvanized steel strip armoured electric power cable with stranded aluminium conductor, 1100 volts grade of size 35 sqmm 3.5 core confirming to is:7098 ( part i ) , suitable for earthed system, laid in duct / trench / along pole / wall etc including nuts, bolts, washers, saddles & screws etc and making connection, complete all as directed. 72 supply, laying, testing and commissioning of lt ug cable, xlpe insulated, pvc sheathed, galvanized steel strip armoured electric power cable with stranded aluminium conductor, 1100 volts grade of size 10 sqmm 2.0 core confirming to is:7098 ( part i ) , suitable for earthed system, laid in duct / trench / along pole / wall etc including nuts, bolts, washers, saddles & screws etc and making connection, complete all as directed. 73 earthing complete with galvanized steel earth plate electrode 600x600x6mm thickburied directly in ground ( earth pit not less than 2..25 mtr deep belownormal ground level ) with top edge ofearth plate not less than 1.5 mtr below the normal ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt, earth lead gi wire 4mm dia ( 8 swg ) connectd to gi earth plate elcectrode by means of bolts, nuts, check nuts, washers of galvanised iron, thimbles and other end of earth wire connected to main switch board and protected by galvanised iron pipe medium grade15mm bore and20mm bore medium grade gi pipewith funnel and wire mesh for watering all as shown in electrc plate no 5 connected to earth test point.40mm thick pre cast rcc m 15 ( nominal mix ) cover reinforced with xpm weight not less than 4 kg / sqm with suitable handle of 6mm dia ms bar and angle iron 40x40x3mm frame for cover, pcc chamber in cement concretem 15 ( nominal mix ) , excavation and earth work in any type of soil and connected all as specified and as directed by engineer in charge. 74 supplying and laying un reinforced precast concrete cable cover, class lv, type i, flat, size 250mm x 150mm x 40mm under ground cables for protection 75 m&l for sand cushioning with layer of sand 8cm thick before laying of cable and 10cm after laying of cable in trenches complete all as directed and sand cover to under ground cablecomplete all as directed. 76 m&l pipe galvanised iron light grade complete with all fittings laid in road crossing, and on pole, buildings complete all as specified and directed isi marked of 40mm bore...

Central Organisation Railway Electrification - Rajasthan

33387033 supply of come along clamps for earth wire 19/2.5mm galvanized steel capacity 2.5tonne with load test certified from govt. approved laboratory.make srec, pvce, sste.]come along clamps for earth wire 19/2.5mm galvanized steel capacity 2.5tonne with load test certified from govt. approved laboratory.make srec, pvce, sste.],come along clamps for earth wire 19/2.5mm galvanized steel capacity 2.5tonne with load test certified from govt. approved laboratory.make srec, pvce, sste....

University of Rajasthan - Rajasthan

33174082 providing and fixing of furniture and air conditioning and other miscellaneous work new central library building university of rajasthan, jaipur ( electric work ) part a : b.s.r. items 2 sitc of interconnecting refrigerantcopper pipe forsplit/ductable/ casseette ac of dhe grade c12200 astm b68, b75, chemical composition of copper % 99.0 min and phosphorus % 0.015 to 0.040 . for annealed copper tube : tensile strength = 210 mpa wih elongation % = 40 min . ink markbrand printing on hard tubes should be present. piping between each set of indoor & outdoor units of different sizesas per oem requirement & specifications including class o nitrile rubber sleeves, chase cutting, supports, making good the same with sand cement plaster etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products/ work, refer annexure a attached with this bsr . 3 providing & fixing of is : 4985 2000 class 4 (10 kgf / sqcm) upvc drain water piping withfittings (is:7834 & 10kgf/sqcm) like elbow, socket, tee, solvent cement jointing,support with ms hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following nominal sizes. all as per pre approved by engineer in charge.for additional technical parameters of products/ work, refer annexure a attached with this bsr . 4 32 mm 5 25 mm 6 making hole in stone masonary/ rcc wall/ rcc slab with core cutter for accomodating refrigerant pipe/ drain pipe/ ms pipe/ cables etc of following dia 7 100 mm dia per running inch length 8 150 mm dia per running inch length 9 providing and making wall openings in existing stone / brick masonary partition wall complete with all requited t & p , scafolding and providing lintel of required size andstrength, repairing ,plastering and cleaning the sitedebrises as required. 10 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed arrmouredaluminiumcable confirming to is:1554 p i / is :7098 p i of 1.1 kv withh4 grade electrolyticaluminium conductor confirming to is 8130 of purity >99.6 %, round / flat strip armouring of cables, inner / outer sheath confirming to is:5831in existing rcc / hume / stoneware / pvc pipe/ open duct/cable trench / cable tray(with cable tie) includingtesting etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810.for additional technical parameters of product / work refer annexure a attached with this bsr 11 16.0 sq. mm 4 core 12 185.0 sq. mm3.5 core 13 supplying and making one end termination with nickel plated heavy duty brass single compression gland (as per is 12943 1990)) sibg type consisting of check nut, gland body, metal washer(3 nos.), outer seal rubber ring,compression nut,heavy duty aluminium lugs (as per is 8309 1993) duly crimped with crimping tool, pvc tape as peris 8337 1976offollowing size ofpvc insulated & pvc sheathed/ xlpe aluminium conductor cable of 1100 volt grade as required.all as per pre approved by engineer in charge. for additional technical parameters of products/ work, refer annexure a attached with this bsr . 14 4 x 16.0 sq.mm 15 3.5 x 185.0 sq.mm 16 supply, fabricating & installing following sizes of perforated hot dipped galvanized iron cable tray ( galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with gi suspenders including gi bolts & nuts , fastners, supports etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products/ work, refer annexure a attached with this bsr . 17 300mm x 50mm x 1.6mm 18 450mm x 50mm x 2.0mm 19 supply & fabrication steel structure with ms channel / angle / joist / ismb / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as requiredcomplete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products/ work, refer annexure a attached with this bsr . 20 sitc of ip 42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andother parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below: 21 (a)thickness of crca sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 22 (b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel.the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 23 [c)interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only.all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar/ flexible wire for interconnection between main busbar and switchgearis to be paid extra ) 24 (d)wiring between components within switchgear and incoming / outgoing cableshall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 25 (e)all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 26 (f)floor mounted panel shall be mounted on base frame of ismcchannel size 100 x 50 x 5 mm( to be paid extra ) 27 (g) tests: the insulation resistance (with 1000 v megger) and high voltage power frequency test (by applying a voltage of 2.5kv for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. the insulation resistance shall not be less than three megaohm. ct secondary current injection test shall also be carried out. 28 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from cpri approved fabricator only (cpri test certificates to be submitted)all as per pre approved by engineer in charge. for additional technical parameters of products/ work, refer annexure a attached with this bsr . 29 supplying and fixing of aluminium (iec 60105 iso 209 1,2) / copper (iec 60028) bus bar by means of smc / dmc type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. all as per pre approved by engineer in charge. for additional technical parameters of products/ work, refer annexure a attached with this bsr .electrolytic grade aluminium bus bar 6010 grade 30 providing & fixing of is: 13875 & iec :61326 confirming led digital type(up to 500) v range volt meter / direct ammeter /ct oertated ammeter/ frequency meter / kwh meter / multi function meter / power analyzer of class 1 accuracyas per is : 1248 of size 96mm x 96 mm including making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products/ work, refer annexure a attached with this bsr .threephase mp+hz+pf+kw+kva+kvar+t.energy+thd i, thd v & run hrs 31 providing & fixing of bis approvedcurrent transformeras per pwd specification for electrical works ,isi marked as peris 2705 1992/ conforming to iec 60044 1, with secondary terminalof ct shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredcurrent transformer ring type tape wound/resin cast wound as per is 16227 with, accuracy cl, ct ratio and burden as specified. isf<=5, cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . all as per pre approved by engineer in charge.all as per pre approved by engineer in charge. for additional technical parameters of products/ work, refer annexure a attached with this bsr .c t class 1, ratio 400/5 to 1200/5, burden 15 va 32 providing & fixing of110/220 v, unibody led indicatinglamp iec 60947with integral circuit, ip 65 above panel &ip 20 terminal block, approx. body dia for panel not less then 20 mm, length min. 50mm, front led cover dia min.29 mm, contact material phospher bronze for led, pcb contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 kv, rated insulation resistance shall be 100 m ohm at 500vdcincluding connection etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products/ work, refer annexure a attached with this bsr . 33 red/yellow/green colour 34 blue / white colour 35 sitc of3 /4pole current limiting moulded case circuit breaker (mccb) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 v, 50 hz; o/l & s/c settings , conforming to is/iec 60947 p 2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, breaking capacity ics = 100% icu. u imp =8 kv, rated insulation voltage690 v.provision for uvr , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.oem shall have submitnabl / cpri / erda accrediated lab type test certificate before execution all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this 4 pole mccb with thermal magnetic release bsr 00 amp , 35 ka, adjustable o/l & adjustable s/c setting, 36 supply and fixing of following accessories for moulded case circuit breaker (mccb)compatible to main mccb oem as per pwd specification for electrical works, conforming to is/iec 60947 p 2 :2003 including making connection etc complete in all respect. oem shall have submitnabl / cpri / erda accrediated lab type test certificate before execution.all as per pre approved by engineer in charge. for additional technical parameters of products/ work, refer annexure a attached with this bsr .extended rotary handle 37 providing & fixing of 240/415 v ac mcb with positive isolation of 10 ka breaking capacity (b/ c/d tripping characteristic as per type of load andsite requirement) 4 kv impulse withstand voltage, isi marked is 8828(1996) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per iec,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 a rating and 10,000 upto 63 a, 5000 for 80 a & above ratingincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr four pole mcb (with b/c curve tripping characteristics)50/63 a rating 38 providing & fixing of 240/415 v factory fitted rcbo with overload, short circuit and earth leakage protectionwith isi marked (is12640 2)/ conforming to iec 61009 1, breaking capacity 10 ka,provision for pad lock, min. electrical operation 10,000 upto 63 a rating , minimum phase termination capacity of 35sq.mm. , ip 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr four pole 100/300 ma sensitivity63 a rating 39 supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % copperthickness (250 microns) andconfirming toul 467, is/iec 62561 2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below : (a) bore a hole of dia. 100 mm of required length, place the rod in the centre of hole (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, cpri/ erdatested with rms capacity of minimum 30 ka for withstanding 1 second .to ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. the compound shall be tested form nabl acredeated labfor lowresistivity ( less than 0.12 ohm meter ) & high conductivity in nature with carbon as a major contentas per referance of is 3043 1987,ieee 80 2013 (clause 14.5d) , ieee 837 & ier 1956 with latest amendemnts © connect the rod with copper strip/conductor/wire with suitable clamp made from tinned copper and ss 304 bolt (d) place heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height250 to 300 mm.(e) test certificatesfor confirming above standards from oem is mandatory. all as per pre approved by engineer in charge.for additional technical parameters of products/ work, refer annexure a attached with this bsr . 17.2 mm thick and 3 mtr. long 40 supply & laying following size earth stripin horizontal or vertical run in surface by means of earth strip dmc insulatorincluding riveting/ soldering/ welding, jointing shall be done by overlapping and with 2 set of brass (for cu strip) / gi (for gi strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products/ work, refer annexure a attached with this bsr .25mm x 6mm g.i. ( hot dipped) strip 41 supply & laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with gi/cu purity purity >95%thimble etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products/ work, refer annexure a attached with this bsr . 8 swg g.i. ( hot dipped) wire ...

Jodhpur Vidyut Vitaran Nigam Limited - Rajasthan

33173406 supply, erection testing commissioning of material for execution of ignp deposit work for 33kv line 33 / 11kv ss at ignp bhanipura 11kv line and 11 0.4 kv ss work under sd khajuwala in bikaner dc for approval direction to float tender on turnkey basis su . 33kv new line in km (22.00km) 2 supply of pcc pole 9.0 mtr. longworking load 400kg. 3 supplyof 36 feet long. u/g lattice structure withchannel cross arm 100x50 mm & top hamper 50x10 mmwith nut & bolts. weight(580.98 kg) approx. 4 supply of 33 kv pin insulator 5 supply of 33 kv gi pin 6 supply ofg.i.stay set 20*2400 mm 7 supply of g.i.stay wire 7/8 swg 8 supply of 33 kv stay insulator 9 supply of stay clamp made of ms flat 50x10 mmweight ( 3.616 kgs.) approx 10 supply of m.s rod type earthing 20 mm dia, 3 mtr. long for earthing 11 supply of g.i.earth wire 6 swg 12 supply overhead steel cored aluminum acsr dog[100sqmm(6+7) /(4.72+1.57)] conductor 13 supply of m.s, nuts & bolts, size, 16 mm(assorted length) 14 supply of 11 kv disc insulator (b&s type, 45 kn) 15 supply of 11 kv disc hardware (b&s type, 45 kn) 16 supply of pg clamp for dog conductor 17 supply of 33 kv double pole line structure setfor cut point complete in all respectas required made from m.s. channel 100x50 x6 mm ismc [9.56 kg. per mtr] isa m.s. angle 65x65x6 ,m.s. angle 50x50x6 mm and m.s. flat 50x10 mm & 50x6 mm [excluding cost of pole]weight(142.314 kgs.) approx 18 supplyof 33kv 800 amp.go(with 18 x 24 kv post insulator )without eb as required including hardwareetc. 19 supply of ms channel 100x50x5 mm 20 b. 33/11 kv randhisar and surjara sub station (2 nos.) 21 supply of pcc pole 9.0 mtr. long working load 400 kg. 22 supply of pcc pole 9.0 mtr. long working load 200 kg. 23 supply of 33/11kv s/s structureon existing pcc poles with clamps made of ms channel 100x50, ms flat 50x6 and ms sheet as per approved design and drawing.weight.(4087 kg) approx. 24 supply of 11/0.4 kv substation structure setonexisting poles in all respect with clamps as required made from m.s. channel 100x50 x6 mm and 75x40 mm, m.s. angle 50x50x6 and m.s. flat 50x6 mm and 50x8 mmweight(148.391 kgs.) approx 25 supplyof 33kv 800 amp.go double break(with 18 x 24 kv post insulator )without eb isolatoras required including hardwareetc. 26 supplyof 11 kv 400 amp.go double break(with 9 x 24 kv post insulator )without eb isolatoras required including hardwareetc. 27 supply of 33 kv horngap fuse set with pi(6x24 kv) 28 supply of 11 kv 3 phase d.o.fuse set(horn gap fuse set) with pi 29 supply of 33 kv pin insulator 30 supply of 33 kv gi pin 31 supply of 11 kv disc insulator (b&s type, 45 kn) 32 supply of 11 kv dischardware (b&s type, 45 kn) 33 supply overhead steel cored aluminum acsr dog[100sqmm(6+7) /(4.72+1.57)] conductor 34 supply of g.i. earth wire 8 swg 35 supply of pg clamp for dog conductor 36 supply of m.s flat 50x8 mm for mesh earthing 37 supply of m.s rod type earthing 20 mm dia, 3 mtr. long for mesh earthing 38 supply of m.s, nuts & bolts, size, 16mm (assorted length) 39 supply of 33kv cross arm channel 40 c. 11 kv new line (115km) 41 supply of pcc pole 9.0 mtr. long working load 200 kg. 42 supply of 11 kv cross arm with top hamper with clamps made of ms angle 75x75x6mm and 65x65x6mm, clamp 50x10mm,earth clamp 50x6mm(wt.=23.486 kgs. approx.)(all galvanized as per relevant is) 43 supply of 11 kv double pole line structure setfor cut point complete in all respectas required made from m.s. channel 100x50 x6 mm ismc [9.56 kg. per mtr] isa m.s. angle 65x65x6 ,m.s. angle 50x50x6 mm and m.s. flat 50x10 mm & 50x6 mm [excluding cost of pole]weight(142.314 kgs.) approx 44 supply of 11kvpin insulator 45 supply of 11kv gi pin 46 supply of 11 kv disc insulator (t&c type, 45 kn) 47 supply of 11 kv dischardware (t&c type, 45 kn) 48 supply overhead steel cored aluminum acsr weasal conductor 49 supply ofg.i.stay set 16*1800 mm 50 supply of g.i.stay wire 7/10 swg 51 supply of 11 kv stay insulator 52 supply of stay clamp made of ms flat 50x10 mmweight ( 3.616 kgs.) approx 53 supply of g.i.earth wire 8 swg 54 supply of pg clamp for rabbit conductor 55 supply of m.s, nuts & bolts, size, 16 mm(assorted length) 56 supply of 11kv cross arm channel 57 supplyof 11 kv 400 amp.go double break(with 9 x 24 kv post insulator )without eb isolatoras required including hardwareetc. 58 supplyof 36 feet long. s/c u/g lattice structure withchannel cross arm 100x50 mm & top hamper 50x10 mmwith nut & bolts. weight(449.85 kg) approx. 59 d. 11/0.4 kv s/s kv (97 nos.) 60 supply of pcc pole 9.0 mtr. long working load 200 kg. 61 supply of 11 kv pin insulator 62 supply of 11 kv gi pin 63 supply of 11/0.4 kv substation structure setonexisting poles in all respect with clamps as required made from m.s. channel 100x50 x6 mm and 75x40x6 mm, m.s. angle 50x50x6 mm and m.s. flat 50x6 mm and 50x8 mmweight(148.391 kgs.) approx 64 supply of 11 kv 3 phase d.o.fuse set cum isolator .(horn gap fuse set) 65 supply ofg.i.stay set 16*1800 mm 66 supply of g.i.stay wire 7/10 swg 67 supply of 11 kv stay insulator 68 supply of stay clamp made of ms flat 50x6 mm suitable for 9 mtr. pcc pole, w.l. 200 kg. 69 supply of 11 kv disc insulator (t&c type, 45 kn) 70 supply of 11 kv disc hardware (t&c type, 45 kn) 71 supply of m.s rod type earthing 20 mm dia, 3 mtr. long set . 72 supply of 11kv v cross arm channel 73 supply of m.s, nuts & bolts, size, 16 mm(assorted length) 74 supply overhead steel cored aluminum acsr rabbit 50sqmm(6+1) /(3.35+3.35)] conductor 75 note (1)the unit base rate for supply of material mentioned in column no. 5 is inclusive of gst @ 18% and freight, insurance & transportation charges of all items(2) the sucessful bidder shall furnish price break upin format provided by this office with acceptance of loi.(3)02 nos. ofpower transformer(33/11kv, 3.15mva), (97+2 = 99 nos.) distribution transformer( 11/0.4kv, 25kva) and08 nos. 12kv outdoor vcb shall be supplied bynigam as free issue item. ...

Urban Improvement Trust - Rajasthan

33117971 various civil works and maintenance works in sub division i area of division ii b ( arc ) civil works clearing and grubbing road land including uprooting rank vegetation, grass, brush, shrubs, saplings and trees of girth upto 300mm, removal of stumps, disposal of unserviceable material and stacking of serviceable material upto 1000m from road boundary. (morth specification : clause 201).by manual means : in area of light jungle 2 clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared. 3 silt clearance of drains, channels and canals with lift 1.5 mtr. and lead up to 50 mtr. 4 earth work in excavation by mechanical means (hydraulic excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. all kinds of soils 5 add extra over item no. 1.8 and 1.9 (sechedule item no 1) for every additional lift of 1.5 m or part thereof : 6 above 1.50 to 3.00m 7 m 35,60mm thick to be used in light traffic (light traffic is defined as a daily traffic up to 150 commercial vehicles exceeding 30 kn laden weight, or an wquivalent up to 0.5 million standerd axles (msa) for a design life of 20 years (a standerd axle is defind as a single axle load of 81.6 kn ) like pedestrain plazes, shopping complexes ramps, car parks, office drveways , housing colonies , office complexes , rural roads with low volume traffic ,fram houses, beach sites, tourist resorts, local authority footwys ,residential roads, etc. 8 category bdenated only two side like i,z,t shape etc. as per irc sp 63:2004 9 random rubble dry stone kharanja under floor. 10 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. 11 m10 grade nominal mix, 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). 12 providing and laying in position specified grade ofcement concrete forall rcc structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. m20 grade nominal mix 13 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.m20 grade nominal mix 14 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.m20 grade nominal mix 15 centering and shuttering with plywood or steel plate including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 16 anti termite treatment of floor using imidacloprid 30.5% ec non repellent, odorless, low dose, environimentally safe terniticide with rapid action non corrosive stain free manufactured by bayer or equivalent company by drilling 12mm diameter holes 300mm apart injecting the emulsion as specified by the manufacturer and plugging with cement mortar 1:2 ( 1 cement : 2 coarse sand) in the whole floor area dpe 12mm dia termitube system with required number of junction boxes are to be installed. the termitube will run all along the perimeter wall both inside and outside. in the middle area the termitube to be installed at an interval of 1.00 mtr. or less both ways as required with sufficient number of junction boxes to pump the emulsion. after successful testing of termitube, pesticide emulsion of imidacloprid 30.5% ec mixed with water in the ration of 1:474 will be pumped by a motorized spray pump from the junction box in specified manner. the plinth area of the area treated will be measured for payment. 17 centering & shuttering with plywood or steel plate including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor three level for : 18 columns, pillars, posts and struts etc. 19 random rubble stone masonry for with hard stone in foundation and plinth in cement sand mortar above 30 cm thick wall in: 20 cement mortar 1:6 ( 1 cement : 6 sand). 21 cement mortar 1:4 ( 1 cement : 4 sand). 22 cement mortar 1:3 ( 1 cement : 3 sand). 23 random rubble stone masonry with hard stone in superstructure aboveplinth level and upto three levelabove 30cm. thick walls in : 24 cement mortar 1:3 ( 1 cement : 3 sand). 25 cement mortar 1:4 ( 1 cement : 4 sand). 26 cement mortar 1:6 ( 1 cement : 6 sand). 27 pointingonstonemasonryincementsandmortar 1:3 (1 cement : 3 sand) : 28 flush / ruled/ struck or weathered pointing. 29 providing and laying damp proof course with cement concrete grade m 150 (1 : 2 : 4) mortar prepared with 1% solution of water proof compound complete and not applying 2 coats of hot bitumen complete as per specifications. 75mm thick 30 50mm thick 31 75 mm thick 32 centering & shuttering with plywood or steel plate including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor three level for : 33 suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 34 providing and fabricating reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. 35 thermo mechanically treated bars (conforming of relevent is code) 36 flyash flyash brick work with flyash flyash bricks of class designation 75 in superstructure above plinth level upto floor three level in all shapes and sizes in : 37 cement mortar 1 : 4 (1 cement : 4 coarse sand) 38 cement mortar 1 : 6 (1 cement : 6 coarse sand) 39 half flyash brick masonry in foundation & plinth using flyash bricks of designation 75 40 cement mortar 1 : 4 (1 cement : 4 coarse sand) 41 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 42 12mm thick. 43 20mm thick. 44 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3 fine sand) 45 making grooves as per design in plaster 10mm to 20mm wide. 46 providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete 47 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : 48 two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect. 49 painting exterior surface ofwallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect. 50 new work 51 providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide 52 painting with synthetic enamel paint of approved brand and manufacture togive an even shade : 53 two or more coats on new work 54 150cm high fencing with angle iron 50x50x6mm. placed at every 3mtr. apart 30cm. in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with 50x50x6mm. angle iron provided with 6 horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed with g.i. staples including earth work in excavation etc. complete. 55 grading roof for water proofing treatment withwater proffing compound 56 cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 57 providing and fixing pressed steel door frames confirming to is 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike plate and shock absorbers as specified and applyinga coat of approved steel primer after pre treatment of the surface including filling with cc 1:2:4(m15 grade) complete as directed by engineer in charge : 58 profile b 59 providing and fixing external grade board solid core single leaf flush door shutters isi 2202 67 marked using phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure a: 30 mm thick . 60 decorative teak veneer both side 61 providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate z sections and other sections of approved make conforming to is :733 and is :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required pvc/neoprene felt etc. aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle aluminium snap beading for glazing /paneling , c.p. brass/ stainless steel screws al. tower bolt & al. handle & al. aldrop etc.,all complete as per architectural drawings and thedirections of engineer in – charge .(glazing and paneling to be paid for separately). : for fixed portion 62 polyester powder coating aluminum( minimum thickness of powder coating 50 micron) 63 providing and fixing of plastic shutter infill made from extruded multi chamber hollow p.v.c. section having cross section of 200 x 20 x 1 mm and shutter frame made from extrude p.v.c. section in the configuration of double walled c section having an overall cross section of 40 x 37 mm and door fittings such as hinges, aldrop, handles, stopper, locking bolt will be provided. 64 providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (is 1038 1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :partly fixed and partly openable [ fixed area not to exceed 33%] 65 for shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). 66 polyester powder coating aluminum( minimum thickness of powder coating 50 micron) 67 providing and fixing superior quality like hardvyn or equivalent hydraulic door closure. 68 providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to is : 13753 & is :15622 of size 300mm x 450mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 69 providing and fixing 1st quality mat finished ceremic tile size 300x300mm confirmingto is : 13755 and is : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 70 providing and fixing 15 to 20 mm thick granite stone slab mirror polished and machine edge cut in walls, pillars, steps, shelves, sills counters, floors etc. laid on 12 mm (av.) thick base of cement mortar 1 : 3 (1 cement : 3 coarse sand) jointing with white cement mortar 1 : 2 (1 white cement : 2 marble dust) with pigment to match the shade of the granite slab complete including rubbing and polishing of : 71 good quality south black above 3601 cm2 slabs 72 extra for providing edge moulding to 15 18mm thick marble/ granite stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 73 granite work (full edge moulding ) 74 p & f 1st quality heavy duty vitrified glazed mat tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to is 15622 of approved make in all colour and shade, laid with 20 mm thick cm 1: 4 including grounting the joints with white cement and matching pigment etc complete. 75 size600 mm x 1200mm 76 providing & fixingbrown kota/ mandana / dholpur/ slate stone incladding / flooring structuralbase with white cement & tinex chemical& ss clamp and fasteners (of approved brand) laid and jointed with white cement slurry mixed with pigment to match the shade of the slab as per drawing attachedcomplete in all respect as per direction of engineer in charge & architect with all lead & lift. the stone measurement will be done of outer most dimension. thickness of stone 25 30mm. 77 polished blue kota stone flooring skirting, laid over 20 mm thick base of c.m. 1 : 4 and jointed with grey cement slurry to match the shade of the slab including rubbing and polishing complete :for area of each slab from 901 to 2000 sq.cm : 78 25 mm thick slab. 79 s/f of fire bricks on edg flooring with fire bricks suitable for 1300 degree centigrade safe working temperature as per is :8 specification laid on & filling of joint by fire resistant mortar/adhesive of required thickness as per directed on a bed of 20 mm thick 1:2 cement mortar of bricks 9 x 4.5x 3 (rate approved year 2008) 80 providing and fixing of glass moisac tiles ( bisseze marke ) size 20 x 20 x 4 mm applied with aaproved adhesive as per specification and direction of engineer in charge 81 providing and fixing staincase railing 90 cm high from nosing of made offollowing specifications. 82 50 mm outer dia (2 mm thick) s.s. pipe hand rail. 83 40 mm outer dia (2 mm thick) s.s. pipe baluster @ 1.00 mtr. 84 4 nos. 20 mm fs. s pipe intermediate runners parallel to hand. 85 s.s. shoe 1.60 mm thick 75 mm outer dia. at each baluster 86 baluster to be welded with s.s. plate 50 mm dia (3 mm thick) anchored in c.c. block with suitable dash fastners 87 50 mm dia & 2 mm thick s.s. pipe for start and end vertical ornamental posts to be provided as per direction of engineer in charge 88 the stainless steel work shall be brushed steel finish with all joints/welds properly grinded to final finish. the stainless steel shall be 304 grade and shall confirm to relevant i.s. 89 providing and fixing steel gate grating and grills made of angles, tees, square bars or other flats black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide.extra if square,rectangular hollow tubularsections are used or grill made by flats only 90 decorative plaster work with spectrum textured coating as per approved colour and shade complete as per manufactures specifications. 91 grit textured @ 2.5 to 3.0 mm thick. 92 ornamental cement plaster in cement sand mortar1 : 4 making kangooras etc. as per jaipurpractice. 93 supplying and fixing machine cutdressed 75 mm pinksand stone (bansi paharpur) dasa/ coping wth ornamental shape having moulding and pan shape engraving as per required pattern with engraving depth of 5 mm (average) in single piece of length 90 cm to be laid on cement mortar 1:4 (12 to 20mm thick) including pointing with admixture of pigment matching with the stone shade. 94 providing corrugated g.s. sheet roofing including vertical / curved surface fixed with polymer coated j or l hooks, bolts and nuts 8 mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces)excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required. 95 0.63 mm thick with zinc coating not less than 275 gm/m2 96 supply & spreading ofgood earth at site complete including loading unloading & transportation etc. 97 supply of dry manure including loading unloading,transportation & stacking at site. 98 farm yard manure(organic) 99 spreading of manure and good earth in required thickness (cost of manure and good earth to be paid separately). 100 laying of lawns including ploughing levelling breaking of clods manuring & removal of stones etc.(cost of manure or extra good earth to be paid seperately) maintenance of lawns for 30 daysor more till the grass forms a thick lawns free from weeds & fit fo 101 in rows 7.5 cms. apart in either direction 102 construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting by vibratory roller 8 10 tonne to meet requirement of table 300 2 including cost of compensation for earth taken from private land with lead upto 1 km as per morth specification : clause no. 305. 103 rough chisel dressed stone flooring over 20 mm (av.) thick base in cm 1 : 6 including pointing with cement mortar 1 : 2 (1 cement : 2 stone dust) with and admixture of pigment to match the shade of stone with joint thickness upto 15 mm : 35 mm thick red sand stone. 104 p & f european type white glazed vitreous china 1st quality double syphonic w.c (is :2556 mark) with p or s trap including cutting and making good the wall and floor 105 p & f indian type white glazed vitreous china 1st quality w.c. orissa pan (is :2556 mark) with 100 mm vitreous china p or s trap including cutting and making good the wall and floor: 106 size 580x440mm. 107 p & f low level flushing cistern of 10 ltr. capacity (is : 2556 mark) o9f approved make with colplete fitting ,c.i. brackets duly painted , brass ball cock with ball, (is :1703 mark)complete including cutting and making good the wall. 108 wvc with c.p. brass bend. 109 p & f wvc wash basin (1st quality, i.s. : 2556 mark) of approved make with c.i. brackets duly painted, 1 no. 15 mm c.p. pillar cock (is : 8934 mark) &32 mm c.p. brass waste coupling of approved make, 25 mm g.i. waste pipe complete including cutting & making good the wall.: 110 size 550 mm x 400 mm dia for counter top 111 1.0 mm thick salem stainless steel aisi 304 & is 13983 1994kitchen sink of approved make (nirali, neel – kanth, jaina, faber castell )with large waste coupling. 112 (24 x 18 x 8) (20x16x8) 113 p & f inlet connection (angle valves) superior quality, of approved make, for wash basin, gyser etc. 114 c.p. inlet connection 15mm.brass (is : 8931 marked) with 37 cm long pipe and nut. 115 p & f pvc storage tank isi marked (is : 12701) indicating thebis license no),of approved make with cover, 25mm dia 1m long g.i. over flow pipe & 25 cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 116 1000 litres capacity. 117 providing and fixingsuperior quality (jaguar contiental ) cp brassfittings complete as per direction of ei 118 bib cock with long thread 15 mm nominal size 119 brass / gunmetalhalf turnwt. 1 kg.ofapprovedquality / make,25mmnominalbore. 120 p & f full way valve (is:778 mark) or wheel valve of approved make 121 gun metal 32mm nominal bore. 122 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. (concealed work including cutting chases and making good the walls etc.,) 123 20mm nominal outer dia pipes 124 32mm nominal outer dia pipes 125 p&f rigid pvc pipe (is:4985 mark) class ii/ (4 kg. /cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 126 110 mm dia 127 160 mm dia 128 p&f rigid pvc pipe fittings (is: 4985 mark) of approved quality / make including joining the pipe with solvent cement rubber ring and lubricant: 129 coupler (socket) 130 110mm dia 131 160 mm dia 132 plain tee 133 110mm dia 134 160mm dia 135 door tee 136 110mm dia 137 bend 45 138 110mm dia 139 vent cowel 140 110mm dia 141 door bend (left & right) 142 110mm dia 143 pipe clip 144 110mm dia 145 plain floor trap 146 110mm dia 147 p trap 148 110mm dia 149 socket plug 150 110mm dia 151 door cap 152 110mm dia 153 construction of chamber in all type of soil with 300 mm thick masonry in cm 1:6 m 10 cm thick c.c. 1:5:10 in foundation, 20mm thick insider plaster in cm 1:6, finished with floating neat cement, 50mm thick m 15 grade c.c. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. 154 do size 450 x 450mm depth upto0.5 m cement cover with frame 155 wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade (is:694) ofapproved make in surface / recessed isi marked medium duty pvc conduit & its accessories, round tiles,hot dipped galvanized modular box with earth terminal, 6 a modular switch,modular plate with grid plate,screws,making connections, testing etc. as required. 156 short point (up to 3 mtr.) 157 medium point (up to 6 mtr.) 158 long point(up to 10 mtr..) 159 wiring of twin control light point with 1.5 sq.mm fr pvc insulated unsheathed flexiable copper conductor 1.1 kv grade and 1.5 sq.mm.fr pvc insulated unsheathed flexiable copper earth conductor 1.1 kv grade(is: 694) of approved make in surface/ recessd isi marked medium duty pvc conduit & its accessories, round tiles, 18 swg m.s. box with earthing terminal, 6 amp two way switch, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. 160 medium point (up to 6 mtr) 161 wiring of 3 pin 6 amp light plug point with 1.5 sq.mm fr pvc insulated unsheathed flexiable copper conductor 1.1 kv grade and 1.5 sq.mm.fr pvc insulated unsheathed flexiable copper conductor 1.1 kv grade(is: 694) of approved make in surface/ recessd isi marked medium duty pvc conduit & its accessories, round tiles, 18 swg m.s. box with earthing terminal, 6 amp switch & 6 amp socket, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. 162 on board 163 medium point (up to 6 mtr) 164 long point (up to 10 mtr) 165 s&f following sizes (dia.) of isi marked medium duty pvc conduit along with accessories in surface / recessed using saddles, clamps, fastener as required includingcutting the wall, covering conduit and making good the same as required. 166 25 mm 167 32 mm 168 50 mm 169 supplying and fixing of power plug point modular accessories on hot dipped galvanized modular on surface or in recessed with suitable size of grid plate with cover plate including cost ofmodular 16 amp. switch and socket outlet, making connection , testing , etc. as required. 170 p&f metal clad industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in sheet steel enclosure (without mcb) including making connections, testing etc.as required 171 single / double pole(three pin) 172 32 a 173 providing & fixing isi marked 6 amp bakelite batten/angle holder including making connection testing etc. as required. 174 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existingsurface or recessed conduit/casing capping including making connections etc. as required. 175 2 x 2.5 sq. mm. + 1x1.5sqmm 176 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 177 p&f 240/415 v ac mcb with positive isolation of breaking capacity not less than 10 ka (b/ c/ d tripping characteristic) isi marked is 8828(1996)]/ conforming to iec 60898 in existing board/sheets including making connections, testing etc. as required. 178 single pole mcb 179 6 a to 32 a rating 180 four pole mcb 181 40 a 63 a rating 182 four pole mcb 183 6 a to 32 a rating 184 p&f recessed/ surface mounting heavy duty horizontal type sheet steel distribution board phophatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar,masking sheet, conforming to is13032 & is8623 including making internal dbterminations with copper lugs , testing etc. as required. 185 double door (single phase) 186 12 way 187 double door (three phase) 188 8 way 189 p/laying p.v.c./ xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved makein ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 190 25.0 sq.mm 191 4 core 192 50.0 sq.mm 193 120.0 sq,mm 194 3.5 core 195 150.0 sq,mm 196 supplying and making one end termination with heavy duty single compression brass gland sibg type, heavy duty aluminium lugs duly crimped with crimping tool, pvc tape etc for following size of armoured pvc insulated & pvc sheathed/ xlpe aluminium conductor cable of 1100 volt grade as required of size. 197 3.5 x 120.0 sq.mm 198 4 x 25.0 sq.mm 199 p/laying p.v.c./ xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with copper conductor of is:1554 p i / is :7098 p i of group 1 of approved makein ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 200 10.0 sq.mm 201 4 core 202 supplying and making one end termination with heavy duty single compression brass gland sibg type, heavy duty copper lugs duly crimped with crimping tool, pvc tape etc for following size of armoured pvc insulated & pvc sheathed/ xlpe aluminium conductor cable of 1100 volt grade as required of size. 203 4 x 10.0 sq.mm 204 sitc of wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel made out of crca sheet , required hardware,duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panel in desired shadethe panel having pu/ neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate m.s. base channel ,hinged door with locking arrangement for equipment/switchgear. thickness of sheet shallnot be less than 1.6 mm up to 600 mm length / widthof any compartment and be of 2.0 mm above 600 mm. load bearing structure shall beof 2.0 mmthick sheet supported by base m.s. channel if required . side walls and cable alley compartments having bolted type doors with / withoutdetachable extension type structure. (only outer area on all sides shall be measured & panel to be fabricated from cpri approved fabricator) 205 supplying and fixing of aluminium / copper bus barby means of smc / dmc type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. 206 electrolytic grade aluminium bus bar 207 sf of (0 500) v range volt meter on existing panel , making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required. 208 analog type ( 96mm x 96mm ) 209 sf of ct operated direct reading typeampere meter on existing panel , making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required. 210 analog type ( 96mm x 96mm ) 211 below 500 a 212 sf ofcurrent transformer, with all necessary support in existing panel including connection etc. as required . 213 up to 150/5 ratio, 10 va, class 1 accuracy 214 sf of selector switch of 10 a for voltmeter (4 position ) including making connection etc.as required . 215 sf of ct linked selector switch of 10 aforampere meter (4 position ) including making connection etc.as required . 216 sf of110/220 v, led (22.5 mm dia ) indicatinglamp with integral circuit, terminal block, including connection etc. as required. 217 red/yellow/green colour 218 supplying and drawing fr pvc insulated & unsheathed flexiable copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. 219 1 x 1.5 sq.mm 220 1 x 2.5 sq.mm 221 1 x 4.0 sq.mm 222 1 x 6.0 sq.mm 223 sitc of self healing mpp/mp type shunt capacitor (banks) conforming to is:13340 41 / iec :831 1&2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( psd ) and shall have dissipation factor less than 0.0025 at 50 hz and total wattage loss less than 0.5 watt per kvar . including making connections with suitable capacity conductors/cables testing etc. as required. 224 heavy duty three phase 440 v , 50 hz capacitor (bank) 225 sitc of microprocessor based three phase sensingpower factor correction relay having following sensing capacitysecondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall havedigit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like kw, kva, kvar,metering facility as required. 226 6 to 8 stage 227 sensitivity upto 50 milli amp 228 p & f ofcam operated rotary switchs on existing panel with 2 way and off postion 229 one pole 230 16 amp 231 p & f of440 volt 3 pole capacitor(ac 6 b ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current, conforming to is:13947 4 1/iec:947 4 1, din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. 232 up to 6 kvar 233 7 to 10 kvar 234 p&f 240/415 v ac mcb with positive isolation of breaking capacity not less than 10 ka (b/ c/ d tripping characteristic) isi marked is 8828(1996)]/ conforming to iec 60898 in existing board/sheets including making connections, testing etc. as required. 235 triple pole mcb 236 6 a to 32 a rating 237 p&f on load change over switch, front handle operated, four pole 415 v conforming to is:13947 p iii including connections , testing etc. as required in the following rating: 238 open execution type 239 200 amp 240 sitc of quick make and quick break4 polecurrent limiting mccb having following current rating, short circuitbreaking capacityat 440/415 v, 50 hz; o/l & s/c settings and conforming to is 60947 2 / iec 60947 2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for uvr , shunt trip ,earth fault trip, push( test) to trip , including making connections with lugs & spreaders,etc. as required. 241 with thermal magnetic release 242 up to 160 amp , 25 ka, adjustable o/l & fixed s/c setting, ics = 100 % icu 243 plate earthing as per is:3043 withcopper earth plate of size 600mm x 600mm x 3.0mm by embodying3 to 4 mtr. below the ground level with 25mm dia. g.i. b class watering pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and c.c.finished chamber covered with hinged type with locking arrangement c.i. cover,c.i. frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. 244 s & laying following size earth wire/stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. 245 8 swg copper wire 246 providing & fixing of heavy duty capacitor start 900/1400 rpm single phase isi marked exhaust fan is:2312 marked in existing opening making connections, testing etc. as required 247 300 mm sweep (900/1400 rpm) 248 p & f double ball bearing capacitor start, aluminium body & blade ceilingfanwith down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. 249 1400 mm sweep 250 p & f of ip 20 led tube light 20 watt with external batten made from crca sheet steel suitable to replace t 8/t 12 tube light, integral driver, 2000 luman + 5% tolerarrce system luman efficiacy of 100 lm/ watt minimum expected life time of 25000 burning hours, cct 5700 k ansi, cri 80, driver efficiency >85%, life expectancy of driver rnin 30000 hrs. pf 0,95 at full load/ 230 volt ac. 251 p & laying xlpe insulated is:7098/ii/85 of group1 and approved make h.t.cable for working voltage 11 k.v.earthed direct in ground including excavation of 30cmx100cm size trench, 25cmlayer of river sand, iind class bricks covering, refilling earth, compaction of earth, making necessary connection testing etc.as required of size. 252 3 core 185.0 sq.mm ...

Ground Water Department - Rajasthan

33059477 supply of auto electric parts wire loom complete, head light, back light, indicator light, break switch, wheel box, arm with blade, fuel meter, ampere metter, flesher lumax, h.l. cutout, fox light, combine switch, electric horn, bulb, pull push switch, vacuun horn, temperature metter, cabin light, wiper machine, self starting button, fuse box, head light holder, denser switch, chassis earth wire, hl bulb, lugs solding, cycle screw with clip, fuse, hitter timer, 4st coil, engine light, waiper blade, waiper arms, key switch, battery lead wire, everest tap, varnise, cotton tap, altnerure light, sleve alternature sleve, wire lugs, solding wire, back light stand, dianamo light, head light ring, indicator light jali....

Department Of Local Bodies - Rajasthan

32818423 work of installation decorative post top lamp with pole on ghoda nikas road ( from ramganj chaupad to char darwaja ) located in the walled city area of municipal corporation jaipur heritage year 2022 23 work of installation decorative post top lamp with pole on ghoda nikas road ( from ramganj chaupad to char darwaja ) located in the walled city area of municipal corporation jaipur heritage year 2022 23 , ( e040106 ) supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from 99.99% purity copper, class 5 stranding in acc. to iec 60228 for lower watt loss , oxygen free ( <10 ppm ) for less chances of oxidization and higher silver content for gives better conductivity , insulation pvc type a or c , flame retardant as per is 10810 53, better amperage rating as per vde 0298 part 4, in existing surface or recessed pvc / ms conduit / casing capping including all as per pre approved by engineer in charge, making connections, etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of products / work , refer annexure a attached with this bsr . 2 x 2.5 sq.mm , ( e110100 ) providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed unarmoured / armoured aluminium cable of 1.1 kv grade as per pwd specification for electrical works in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points ( a ) , ( b ) , ( c ) , mentioned below: ( a ) material : h4 grade aluminium conductor of purity >99.6 % & as per is:1554 p i / is :7098 p – i ( b ) conductor shall have electrolytic aluminium confirming to is 8130, is 3975 1999 for armouring of cables in armoured cable items , is 5831 for sheath, is 10810 ( part 0 to 64 ) for testing procedures. ( c ) oem must have iso 9001 & 14001 certifications for quality assuarance & its own in house nabl lab setup for all testing facilities for cables . appropriate type test certificate / oem test report shall be submitted . all above as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr. , ( e110133 ) 10.0 sq. mm , ( e110133a ) 2 core , ( e110134 ) 16.0 sq. mm , ( e110134d ) 4 core , ( e120100 ) supplying and making one end termination with heavy duty brass compression gland ( as per is 12943 1990 ) sibg type, heavy duty aluminium lugs ( as per is 8309 1993 & is 8337 1976 ) duly crimped with crimping tool, pvc tape as per pwd specification for electrical works etc for following size of armoured pvc insulated & pvc sheathed / xlpe aluminium conductor cable of 1100 volt grade as required of size. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . , ( e120139 ) 4 x 25.0 sq.mm , ( e120138 ) 4 x 16.0 sq.mm , ( e140514 ) sitc of chemical gel earthing system of dual pipe technology made of with b class g i pipe as per is 1239 ( part 1 ) :2004 of medium duty of following sizes as per points mentioned ( a ) , ( b ) , [ c ) , ( d ) , ( e ) below : ( a ) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, cpri / erda tested with rms capacity of minimum 35 40 ka for withstanding 1 second . ( b ) to ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. the compound shall be tested form nabl acredeated lab for low resistivity ( less than 0.12 ohm meter ) & high conductivity in nature with carbon as a major content as per referance of is 3043 1987, ieee 80 2013 ( clause 14.5d ) , ieee 837 & ier 1956 with latest amendemnts ( c ) heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height 250 to 300 mm. ( d ) testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. ( e ) self certificate for confirming above standards from oem is mandatory. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . with pipe in pipe technology ( outer pipe dia. / inner pipe dia. ) minimum 100 mm dia borewell gi pipe 3000 mm long, 80 / 50 mm, terminal 50mm x 6mm gi strip , ( e140702 ) supply & laying following size earth wire in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection with gi / cu thimble etc. as required. all as per pre approved by engineer in charge. for additional technicalparameters of products / work , refer annexure a attached with this bsr . 8 swg copper wire , ( e210411 ) providing & fixing of hdpe pipe isi mark ( is:4984 / 2016 ) for water supply ( suitable for submersible & jet pump ) with required fittings ie socket, elbows, tee etc. complete in all respect. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . for vertical installation 40 mm od 6 kg / cm2....

Department Of Local Bodies - Rajasthan

32818402 work of installation decorative post top lamp with pole from subhash chowk to char darwaja located in the walled city area of municipal corporation jaipur heritage year 2022 23 work of installation decorative post top lamp with pole from subhash chowk to char darwaja located in the walled city area of municipal corporation jaipur heritage year 2022 23 , ( e040106 ) supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from 99.99% purity copper, class 5 stranding in acc. to iec 60228 for lower watt loss , oxygen free ( <10 ppm ) for less chances of oxidization and higher silver content for gives better conductivity , insulation pvc type a or c , flame retardant as per is 10810 53, better amperage rating as per vde 0298 part 4, in existing surface or recessed pvc / ms conduit / casing capping including all as per pre approved by engineer in charge, making connections, etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of products / work , refer annexure a attached with this bsr . 2 x 2.5 sq.mm , ( e110100 ) providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed unarmoured / armoured aluminium cable of 1.1 kv grade as per pwd specification for electrical works in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points ( a ) , ( b ) , ( c ) , mentioned below: ( a ) material : h4 grade aluminium conductor of purity >99.6 % & as per is:1554 p i / is :7098 p – i ( b ) conductor shall have electrolytic aluminium confirming to is 8130, is 3975 1999 for armouring of cables in armoured cable items , is 5831 for sheath, is 10810 ( part 0 to 64 ) for testing procedures. ( c ) oem must have iso 9001 & 14001 certifications for quality assuarance & its own in house nabl lab setup for all testing facilities for cables . appropriate type test certificate / oem test report shall be submitted . all above as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr. , ( e110133 ) 10.0 sq. mm , ( e110133a ) 2 core , ( e110134 ) 16.0 sq. mm , ( e110134d ) 4 core , ( e120100 ) supplying and making one end termination with heavy duty brass compression gland ( as per is 12943 1990 ) sibg type, heavy duty aluminium lugs ( as per is 8309 1993 & is 8337 1976 ) duly crimped with crimping tool, pvc tape as per pwd specification for electrical works etc for following size of armoured pvc insulated & pvc sheathed / xlpe aluminium conductor cable of 1100 volt grade as required of size. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . , ( e120139 ) 4 x 25.0 sq.mm , ( e120138 ) 4 x 16.0 sq.mm , ( e140514 ) sitc of chemical gel earthing system of dual pipe technology made of with b class g i pipe as per is 1239 ( part 1 ) :2004 of medium duty of following sizes as per points mentioned ( a ) , ( b ) , [ c ) , ( d ) , ( e ) below : ( a ) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, cpri / erda tested with rms capacity of minimum 35 40 ka for withstanding 1 second . ( b ) to ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. the compound shall be tested form nabl acredeated lab for low resistivity ( less than 0.12 ohm meter ) & high conductivity in nature with carbon as a major content as per referance of is 3043 1987, ieee 80 2013 ( clause 14.5d ) , ieee 837 & ier 1956 with latest amendemnts ( c ) heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height 250 to 300 mm. ( d ) testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. ( e ) self certificate for confirming above standards from oem is mandatory. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . with pipe in pipe technology ( outer pipe dia. / inner pipe dia. ) minimum 100 mm dia borewell gi pipe 3000 mm long, 80 / 50 mm, terminal 50mm x 6mm gi strip , ( e140702 ) supply & laying following size earth wire in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection with gi / cu thimble etc. as required. all as per pre approved by engineer in charge. for additional technicalparameters of products / work , refer annexure a attached with this bsr . 8 swg copper wire , ( e210411 ) providing & fixing of hdpe pipe isi mark ( is:4984 / 2016 ) for water supply ( suitable for submersible & jet pump ) with required fittings ie socket, elbows, tee etc. complete in all respect. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . for vertical installation 40 mm od 6 kg / cm2....

Indian Institute Of Technology - Rajasthan

32552046 supply, installation, testing and commissioning of indoor led video wall ( display system ) in lecture hall building supply, installation, testing and commissioning of indoor led video wall ( display system ) in lecture hall building , supply, installation, testing and commissioning of p 3 configuration led video wall panel of specified specification attached above including fixing arrangement nut bolt etc as required as per engineer in charge. ( as per specification ) , supply, installation, testing and commissioning of video controller system of specified specification attached above etc. as required as per engineer in charge. ( as per specification ) , supply and installation of gi / aluminum structure arrangement for fixing led video wall system including exhaust fan for air ventilation as specified above including fastener / clamp etc. as required as per engineer in charge. ( as per specification ) , wiring for circuit / submain wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed steel conduit as required: 4 x 6 sq. mm + 2 x 6 sq. mm earth wire. , supplying and fixing 30 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. ( as per specification ) , supplying and drawing of utp 4 pair cat 6 lan cable in the existing surface / recessed steel / pvc conduit as required: 1 run of cable. , sitc of single utp cat6a i / o of specified make including mounting inside singlex and ms back box assembly ( if required ) as per requirement, inclusive of termination of utp cat6a cable at each io at workstation area / device / user side / panel side etc. as required ( as per specification ) , supply of extra clamps and fixing structure ( movable type ) for relocating the video wall at any desired location without needing to remove the fixed clamps on the wall. ( as per specification ) ...

Jaipur Vidyut Vitran Nigam Limited - Rajasthan

32465995 supply erection installation and commissioning of material equipment for the work of release of ag connection in fy 2022 23 on turnkey basis in respect of dausa lot i circle under the domain of jaipur discom against supply of material (all material shall be supplied as per specification enclosed with the bidding documents): 2 9 mtr. long pcc poles of 200 kg working load with factor of safty 2.5. 3 33 kv s/c lattice structure (36 ungalvanised with 1 nos 33 kv cross arm(channel) with required nuts and bolts. 4 11/0.433 kv, 40 kva aluminium wound bis level 2 completely self protected (csp) distribution transformers with provisio of lt bushing box 5 25 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 6 16 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 7 galvanised steel stay set 16x1800 mm 8 11 kv stay insulator 9 galvanised steel stay wire 7/10 swg 10 stay set clamps suitable for 9 mtr. long pcc poles 11 h/w for disc insulators 45kn t&c type 12 disc insulators 45kn t&c type 13 m.s. nuts & bolts (assorted size) 14 acsr rabbit conductor 15 11 kv v cross arm with top hamper and clamps ( angle) 16 galvanized m.s. froged 11 kv pin 17 11 kv pin insulator 18 11/0.4 kv s/s structure set for 3 ph 40/25/ 16 kva transformer on double pole 19 horn gap fuse set with post insulator 11 kv 20 ms rod type earthing set with wire & clamp with following details(1 no. galvanised m.s. rod 20 mm dia electrodes having3 meter length, 2 nos. galvanised earthing clamp of m.s.flat of size 50x6 mm 220 mm length. one welded with earthelectrode and loose to be bolted; 2 nos. galvanised bolts, nuts and spring washers and g.i.wire size 8 swg of 15 meter length) 21 1.4 mtr channel 100x50x6 mm bracket with clamp 22 4c x 16 sq. mm. lt pvc insulated pvc sheathed cable (armoured) 23 m.s. angles 75 x 75 x 6 mm (for guarding) 24 three phase four wire whole current meter of rating 10 60 a having backlit lcd display with meter box (free issue). 25 m.s. channel 75 x 40 x 6 mm (for extension bracket) 26 lt shunt capacotors 3 kvar 27 lt shunt capacotors 6 kvar 28 danger plate 29 11 kv line dp set 30 p.g. clamps for rabbit 31 g.s. earth wire 8 swg 32 erection of material: 33 trimming of tree branches/plants and preparing route approchases for proposed line. 34 excavation of pit in hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 35 (a) height of poles/r.s.joist/m.s. rail /size of pit 36 9 mtr/ 1.2mx0.6mx1.50 m deep 37 (b) lattice tower /size of pit 38 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 39 (c)stay set/depth of pit 40 6x5/8 0.75x0.5x1.35m 41 excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 42 (a) height of poles/r.s.joist/m.s. rail /size of pit 43 9 mtr/ 1.2mx0.6mx1.50 m deep 44 (b) lattice tower /size of pit 45 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 46 (c)stay set/depth of pit 47 6x5/8 0.75x0.5x1.35m 48 safe carriage of pcc poles including loading / un loading 49 c) 9 mtr.long 200 kg. pcc pole 50 within10 kms. 51 above 10 km. & upto 30 km. add foreach km. or part thereof 52 above 30 km. add for each km. or part thereof (50 km) 53 safe carriage of steel( fabricated and unfabricated) i.e.m.s. rails, r.s.joists, m.s.channels, m.s.angles, m.s.flat, g.i.stay sets, g.i. stay wire, g.i.wire nut & bolts etc. and acsr conductor including loading and unloading and stacking in nigam store /at work site 54 within10 kms. 55 above 10 kms. & upto 30 kms. add for each km.or part thereof. 56 above 30 kms. add for each kms. or partthereof. (50 km) 57 safe carriage of insulator, hardware, cable etc.including loading/unloading and stacking in nigam.stores etc. 58 within10 kms. 59 above 10 kms. & upto 30 kms. add for each km.or part thereof. 60 above 30 kms. add for each kms.or part thereof. (50 km) 61 safe carriage of fabricated lattice towers structures and sub station structures type ab, ab beams, isolators structures etc. including loading/unloading and stacking in the nigam. stores / at work site. 62 within10 kms. 63 above 10 kms. & upto 30 kms. add for each km.or part thereof. 64 above 30 kms. add for each kms.or part thereof.(50 km) 65 safe carriage of 11/.4 kv 3 phase distribution transformer including loading/unloading and stacking in nigam.stores etc. 66 10 &16 kva 67 within10 kms. 68 above 10 kms. & upto 30 kms. add for each km.or part thereof. 69 above 30 kms. add for each kms.or part thereof. (50 km) 70 25 & 40 kva 71 within10 kms. 72 above 10 kms. & upto 30 kms. add for each km.or part thereof. 73 above 30 kms. add for each kms.or part thereof. (50 km) 74 erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. the support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item no. 5.6 the remaining portion of the pit will be back filled with soil. the nuts & bolts will be provided by the contractor as per nigams specification for which payment will be made at the prevailing store issue rates. the cost muffing and grouting will be paid extra. 75 lattice structure 76 erection of pcc poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractor as per nigams specification for which the payment will be made at the prevailing discom store issue rates. 77 in rural area 78 pcc poles 9 mtr. long(200kg.) 79 erection & assembly of 2 pole structures ofof steel supports or of pcc poles in excavated pit in alignment afterchecking the same with plumb line. including fixing of top bracing of m.s. channels with pilot plates and clamps. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractoras per nigams specfication for which the payment will be made at the prevailing discom store issue rates. 80 pcc poles 9 mtr. long(200kg.) 81 erection & fixing of g.i.stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.the work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension.size of stay set/stay wire 82 6x5/8 with 7/10 swg stay wire 83 providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.(1.2x1.2 x2.1 m)/tower 84 fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub station. 85 fixing of guarding bracket arms with clamp on erected support as per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 86 11 kv line 87 fixing of earth wire clamp on erected supportas per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 88 fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. the nuts &bolts are to be provided by the contractor as per nigams specification for which payment will be made as perprevailing discom store issue rates. 89 11 kv line 90 fixing and assembly of disc. point channel pair with pilot plates & clamps on erected single pole structure as per design. the nuts & bolts are to be provided by the contractor as per nigams specification for which payment will be made as per prevailingdiscom store issue rates. 91 11 kv line 92 fixing of 11kv b&s/t&c type disc insulator of 11kv lines(each unit consiting of 1nos.disc.& 1set of h/ w ) on terminal point including fixing of hardware and strips. 93 fixing of 11 kv pininsulator with pins. 94 ssembly and installation of horn gap fuse set (set of 3 nos)on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. the nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing discom store issue rates. 95 11kv horn gap fuse set. 96 installation testing as per nigams norm & commissioning of11/0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on hv&lv side, crimping of lugs/clamping earth connections of body and neutral of transformer with wire/strip (as already provided with earthing) complete in all respect. the pg clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing discom store issue rates. 97 10 & 16 kva 98 25 & 40 kva 99 fixing of danger plates on supports/structure 100 fixing of pg clamp of weasel /rabbit conductor 101 laying, jointing , stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire/p.g. clamps aluminium jointing sleeves will be used for jointing the conductor. the line must stand at proper voltage on charging. the contractor will be provide p.g. clamps for which payment will be made as per prevailing discom store issue rates. 102 acsr rabbit 103 laying, jointing,stringing,tensioning and clamping of g.i.earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.the nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing discom store issue rates. 104 (b) in rural area 105 g.i.earth wire 8 swg 106 drawing & strining of g.i 4 wire over the guarding brackets for guarding of road crossing /p&t crossing/railway track crossing (for one span only)with cross g.i wire laces at an intraval of two meter each or required as per location using eye bolt nuts. 107 8 swg with laces of 10 swg 108 earthing of line for all type of supports as per rec construction standards using stay wire/gi wire with one pcs of m.s. rod 20mm dia each 3 meter long and driving into earth by mechanical means ms rod, ms flat & stay wire will be supplied by the contractor. ifmaterial is supplied by the contractor the payment will be made as per prevailing discom store issue rates.(in case of pcc poles earthing mustbe connected with earthwire already available on pcc pole at bottom) 109 earthing of 11/0.4 kv distribution transformer /sub station with 3 pieces of m.s. rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. the work includes flattening of top ends of m.s. rod drilling a hole of 9/16 dia. at flattened top and tightening of m.s. flat 50x6mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with m.s. rod. top end hole. the flat will also be welded with m.s. rod. the end will be connected to equipments as under as under in sequence. 110 fixing of three phase meter cummeter box(complete unit)at the premises of existing/new consumerswith 4 nos anchor fastners with rust proof size m 6x50 mm on the wall as per the positionof holes already provided on the meter box. the meter box must be housed perfectly vertical/plumb line,anchor fasteners are to be supplied/provided by the contractor including safe carriage from s/d store to consumers site and depositing removed meter and meter box if any in s/d store). 111 in rural area 112 laying of 1100 volt heavy duty armoured xlpe cable of aluminum coudctor of following size conforming to is: 7098 (pt i) (latest amended) overhead service line from pole to meter terminals for release of new lt connections/replacement of damaged/obsolete service line (except agriculture one). the cable must be fixed on wall with clamps /hooks properly at a interval of one meter. 113 4 core 16/25 sq. mm 114 fixing of 3 phase lt shunt capacitor (3/6/9/12kvar) near starterof motor for agriculature consumers to be fixed with ms clamp of shape of size 2x10mm having two nos.holes for fixing of lt capacitors besides starter of consumer with the help of two no.machine screw. the starter shall be connected using pvc sheathed single core of 4 sq.mm ai. cable conforming to relevant is. the wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with ms compoundpvc tape roll. the ends of wire shall be properly crimped with lugsthimble etc.all material shall be supplied by the contractor except lt shunt capacitor (the lt shunt capacitor shall be supplied by nigam) ...

Jaipur Vidyut Vitran Nigam Limited - Rajasthan

32465992 supply erection installation and commissioning of material equipment for the work of release of ag connection in fy 2022 23 on turnkey basis in respect of dholpur lot i circle under the domain of jaipur discom against tn 523. supply erection under the domain of jaipur discom against tn 523. supply of material (all material shall be supplied as per specification enclosed with the bidding documents): 2 9 mtr. long pcc poles of 200 kg working load with factor of safty 2.5. 3 33 kv s/c lattice structure (36 ungalvanised with 1 nos 33 kv cross arm(channel) with required nuts and bolts. 4 11/0.433 kv, 40 kva aluminium wound bis level 2 completely self protected (csp) distribution transformers with provisio of lt bushing box 5 25 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 6 16 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 7 galvanised steel stay set 16x1800 mm 8 11 kv stay insulator 9 galvanised steel stay wire 7/10 swg 10 stay set clamps suitable for 9 mtr. long pcc poles 11 h/w for disc insulators 45kn t&c type 12 disc insulators 45kn t&c type 13 m.s. nuts & bolts (assorted size) 14 acsr rabbit conductor 15 11 kv v cross arm with top hamper and clamps ( angle) 16 galvanized m.s. froged 11 kv pin 17 11 kv pin insulator 18 11/0.4 kv s/s structure set for 3 ph 40/25/ 16 kva transformer on double pole 19 horn gap fuse set with post insulator 11 kv 20 ms rod type earthing set with wire & clamp with following details(1 no. galvanised m.s. rod 20 mm dia electrodes having3 meter length, 2 nos. galvanised earthing clamp of m.s.flat of size 50x6 mm 220 mm length. one welded with earthelectrode and loose to be bolted; 2 nos. galvanised bolts, nuts and spring washers and g.i.wire size 8 swg of 15 meter length) 21 1.4 mtr channel 100x50x6 mm bracket with clamp 22 4c x 16 sq. mm. lt pvc insulated pvc sheathed cable (armoured) 23 m.s. angles 75 x 75 x 6 mm (for guarding) 24 three phase four wire whole current meter of rating 10 60 a having backlit lcd display with meter box (free issue). 25 m.s. channel 75 x 40 x 6 mm (for extension bracket) 26 lt shunt capacotors 3 kvar 27 lt shunt capacotors 6 kvar 28 danger plate 29 11 kv line dp set 30 p.g. clamps for rabbit 31 g.s. earth wire 8 swg 32 erection of material: 33 trimming of tree branches/plants and preparing route approchases for proposed line. 34 excavation of pit in hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 35 (a) height of poles/r.s.joist/m.s. rail /size of pit 36 9 mtr/ 1.2mx0.6mx1.50 m deep 37 (b) lattice tower /size of pit 38 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 39 (c)stay set/depth of pit 40 6x5/8 0.75x0.5x1.35m 41 excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 42 (a) height of poles/r.s.joist/m.s. rail /size of pit 43 9 mtr/ 1.2mx0.6mx1.50 m deep 44 (b) lattice tower /size of pit 45 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 46 (c)stay set/depth of pit 47 6x5/8 0.75x0.5x1.35m 48 safe carriage of pcc poles including loading / un loading 49 c) 9 mtr.long 200 kg. pcc pole 50 within10 kms. 51 above 10 km. & upto 30 km. add foreach km. or part thereof 52 above 30 km. add for each km. or part thereof (50 km) 53 safe carriage of steel( fabricated and unfabricated) i.e.m.s. rails, r.s.joists, m.s.channels, m.s.angles, m.s.flat, g.i.stay sets, g.i. stay wire, g.i.wire nut & bolts etc. and acsr conductor including loading and unloading and stacking in nigam store /at work site 54 within10 kms. 55 above 10 kms. & upto 30 kms. add for each km.or part thereof. 56 above 30 kms. add for each kms. or partthereof. (50 km) 57 safe carriage of insulator, hardware, cable etc.including loading/unloading and stacking in nigam.stores etc. 58 within10 kms. 59 above 10 kms. & upto 30 kms. add for each km.or part thereof. 60 above 30 kms. add for each kms.or part thereof. (50 km) 61 safe carriage of fabricated lattice towers structures and sub station structures type ab, ab beams, isolators structures etc. including loading/unloading and stacking in the nigam. stores / at work site. 62 within10 kms. 63 above 10 kms. & upto 30 kms. add for each km.or part thereof. 64 above 30 kms. add for each kms.or part thereof.(50 km) 65 safe carriage of 11/.4 kv 3 phase distribution transformer including loading/unloading and stacking in nigam.stores etc. 66 10 &16 kva 67 within10 kms. 68 above 10 kms. & upto 30 kms. add for each km.or part thereof. 69 above 30 kms. add for each kms.or part thereof. (50 km) 70 25 & 40 kva 71 within10 kms. 72 above 10 kms. & upto 30 kms. add for each km.or part thereof. 73 above 30 kms. add for each kms.or part thereof. (50 km) 74 erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. the support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item no. 5.6 the remaining portion of the pit will be back filled with soil. the nuts & bolts will be provided by the contractor as per nigams specification for which payment will be made at the prevailing store issue rates. the cost muffing and grouting will be paid extra. 75 lattice structure 76 erection of pcc poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractor as per nigams specification for which the payment will be made at the prevailing discom store issue rates. 77 in rural area 78 pcc poles 9 mtr. long(200kg.) 79 erection & assembly of 2 pole structures ofof steel supports or of pcc poles in excavated pit in alignment afterchecking the same with plumb line. including fixing of top bracing of m.s. channels with pilot plates and clamps. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractoras per nigams specfication for which the payment will be made at the prevailing discom store issue rates. 80 pcc poles 9 mtr. long(200kg.) 81 erection & fixing of g.i.stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.the work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension.size of stay set/stay wire 82 6x5/8 with 7/10 swg stay wire 83 providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.(1.2x1.2 x2.1 m)/tower 84 fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub station. 85 fixing of guarding bracket arms with clamp on erected support as per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 86 11 kv line 87 fixing of earth wire clamp on erected supportas per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 88 fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. the nuts &bolts are to be provided by the contractor as per nigams specification for which payment will be made as perprevailing discom store issue rates. 89 11 kv line 90 fixing and assembly of disc. point channel pair with pilot plates & clamps on erected single pole structure as per design. the nuts & bolts are to be provided by the contractor as per nigams specification for which payment will be made as per prevailingdiscom store issue rates. 91 11 kv line 92 fixing of 11kv b&s/t&c type disc insulator of 11kv lines(each unit consiting of 1nos.disc.& 1set of h/ w ) on terminal point including fixing of hardware and strips. 93 fixing of 11 kv pininsulator with pins. 94 ssembly and installation of horn gap fuse set (set of 3 nos)on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. the nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing discom store issue rates. 95 11kv horn gap fuse set. 96 installation testing as per nigams norm & commissioning of11/0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on hv&lv side, crimping of lugs/clamping earth connections of body and neutral of transformer with wire/strip (as already provided with earthing) complete in all respect. the pg clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing discom store issue rates. 97 10 & 16 kva 98 25 & 40 kva 99 fixing of danger plates on supports/structure 100 fixing of pg clamp of weasel /rabbit conductor 101 laying, jointing , stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire/p.g. clamps aluminium jointing sleeves will be used for jointing the conductor. the line must stand at proper voltage on charging. the contractor will be provide p.g. clamps for which payment will be made as per prevailing discom store issue rates. 102 acsr rabbit 103 laying, jointing,stringing,tensioning and clamping of g.i.earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.the nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing discom store issue rates. 104 (b) in rural area 105 g.i.earth wire 8 swg 106 drawing & strining of g.i 4 wire over the guarding brackets for guarding of road crossing /p&t crossing/railway track crossing (for one span only)with cross g.i wire laces at an intraval of two meter each or required as per location using eye bolt nuts. 107 8 swg with laces of 10 swg 108 earthing of line for all type of supports as per rec construction standards using stay wire/gi wire with one pcs of m.s. rod 20mm dia each 3 meter long and driving into earth by mechanical means ms rod, ms flat & stay wire will be supplied by the contractor. ifmaterial is supplied by the contractor the payment will be made as per prevailing discom store issue rates.(in case of pcc poles earthing mustbe connected with earthwire already available on pcc pole at bottom) 109 earthing of 11/0.4 kv distribution transformer /sub station with 3 pieces of m.s. rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. the work includes flattening of top ends of m.s. rod drilling a hole of 9/16 dia. at flattened top and tightening of m.s. flat 50x6mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with m.s. rod. top end hole. the flat will also be welded with m.s. rod. the end will be connected to equipments as under as under in sequence. 110 fixing of three phase meter cummeter box(complete unit)at the premises of existing/new consumerswith 4 nos anchor fastners with rust proof size m 6x50 mm on the wall as per the positionof holes already provided on the meter box. the meter box must be housed perfectly vertical/plumb line,anchor fasteners are to be supplied/provided by the contractor including safe carriage from s/d store to consumers site and depositing removed meter and meter box if any in s/d store). 111 in rural area 112 laying of 1100 volt heavy duty armoured xlpe cable of aluminum coudctor of following size conforming to is: 7098 (pt i) (latest amended) overhead service line from pole to meter terminals for release of new lt connections/replacement of damaged/obsolete service line (except agriculture one). the cable must be fixed on wall with clamps /hooks properly at a interval of one meter. 113 4 core 16/25 sq. mm 114 fixing of 3 phase lt shunt capacitor (3/6/9/12kvar) near starterof motor for agriculature consumers to be fixed with ms clamp of shape of size 2x10mm having two nos.holes for fixing of lt capacitors besides starter of consumer with the help of two no.machine screw. the starter shall be connected using pvc sheathed single core of 4 sq.mm ai. cable conforming to relevant is. the wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with ms compoundpvc tape roll. the ends of wire shall be properly crimped with lugsthimble etc.all material shall be supplied by the contractor except lt shunt capacitor (the lt shunt capacitor shall be supplied by nigam) ...

Jaipur Vidyut Vitran Nigam Limited - Rajasthan

32465910 supply erection installation and commissioning of material equipment for the work of release of ag connection in fy 2022 23 on turnkey basis in respect of baran lot i circle under the domain of jaipur discom against tn 523. supply of material (all material shall be supplied as per specification enclosed with the bidding documents): 2 9 mtr. long pcc poles of 200 kg working load with factor of safty 2.5. 3 33 kv s/c lattice structure (36 ungalvanised with 1 nos 33 kv cross arm(channel) with required nuts and bolts. 4 11/0.433 kv, 40 kva aluminium wound bis level 2 completely self protected (csp) distribution transformers with provisio of lt bushing box 5 25 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 6 16 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 7 galvanised steel stay set 16x1800 mm 8 11 kv stay insulator 9 galvanised steel stay wire 7/10 swg 10 stay set clamps suitable for 9 mtr. long pcc poles 11 h/w for disc insulators 45kn t&c type 12 disc insulators 45kn t&c type 13 m.s. nuts & bolts (assorted size) 14 acsr rabbit conductor 15 11 kv v cross arm with top hamper and clamps ( angle) 16 galvanized m.s. froged 11 kv pin 17 11 kv pin insulator 18 11/0.4 kv s/s structure set for 3 ph 40/25/ 16 kva transformer on double pole 19 horn gap fuse set with post insulator 11 kv 20 ms rod type earthing set with wire & clamp with following details(1 no. galvanised m.s. rod 20 mm dia electrodes having3 meter length, 2 nos. galvanised earthing clamp of m.s.flat of size 50x6 mm 220 mm length. one welded with earthelectrode and loose to be bolted; 2 nos. galvanised bolts, nuts and spring washers and g.i.wire size 8 swg of 15 meter length) 21 1.4 mtr channel 100x50x6 mm bracket with clamp 22 4c x 16 sq. mm. lt pvc insulated pvc sheathed cable (armoured) 23 m.s. angles 75 x 75 x 6 mm (for guarding) 24 three phase four wire whole current meter of rating 10 60 a having backlit lcd display with meter box (free issue). 25 m.s. channel 75 x 40 x 6 mm (for extension bracket) 26 lt shunt capacotors 3 kvar 27 lt shunt capacotors 6 kvar 28 danger plate 29 11 kv line dp set 30 p.g. clamps for rabbit 31 g.s. earth wire 8 swg 32 erection of material: 33 trimming of tree branches/plants and preparing route approchases for proposed line. 34 excavation of pit in hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 35 (a) height of poles/r.s.joist/m.s. rail /size of pit 36 9 mtr/ 1.2mx0.6mx1.50 m deep 37 (b) lattice tower /size of pit 38 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 39 (c)stay set/depth of pit 40 6x5/8 0.75x0.5x1.35m 41 excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 42 (a) height of poles/r.s.joist/m.s. rail /size of pit 43 9 mtr/ 1.2mx0.6mx1.50 m deep 44 (b) lattice tower /size of pit 45 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 46 (c)stay set/depth of pit 47 6x5/8 0.75x0.5x1.35m 48 safe carriage of pcc poles including loading / un loading 49 c) 9 mtr.long 200 kg. pcc pole 50 within10 kms. 51 above 10 km. & upto 30 km. add foreach km. or part thereof 52 above 30 km. add for each km. or part thereof (50 km) 53 safe carriage of steel( fabricated and unfabricated) i.e.m.s. rails, r.s.joists, m.s.channels, m.s.angles, m.s.flat, g.i.stay sets, g.i. stay wire, g.i.wire nut & bolts etc. and acsr conductor including loading and unloading and stacking in nigam store /at work site 54 within10 kms. 55 above 10 kms. & upto 30 kms. add for each km.or part thereof. 56 above 30 kms. add for each kms. or partthereof. (50 km) 57 safe carriage of insulator, hardware, cable etc.including loading/unloading and stacking in nigam.stores etc. 58 within10 kms. 59 above 10 kms. & upto 30 kms. add for each km.or part thereof. 60 above 30 kms. add for each kms.or part thereof. (50 km) 61 safe carriage of fabricated lattice towers structures and sub station structures type ab, ab beams, isolators structures etc. including loading/unloading and stacking in the nigam. stores / at work site. 62 within10 kms. 63 above 10 kms. & upto 30 kms. add for each km.or part thereof. 64 above 30 kms. add for each kms.or part thereof.(50 km) 65 safe carriage of 11/.4 kv 3 phase distribution transformer including loading/unloading and stacking in nigam.stores etc. 66 10 &16 kva 67 within10 kms. 68 above 10 kms. & upto 30 kms. add for each km.or part thereof. 69 above 30 kms. add for each kms.or part thereof. (50 km) 70 25 & 40 kva 71 within10 kms. 72 above 10 kms. & upto 30 kms. add for each km.or part thereof. 73 above 30 kms. add for each kms.or part thereof. (50 km) 74 erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. the support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item no. 5.6 the remaining portion of the pit will be back filled with soil. the nuts & bolts will be provided by the contractor as per nigams specification for which payment will be made at the prevailing store issue rates. the cost muffing and grouting will be paid extra. 75 lattice structure 76 erection of pcc poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractor as per nigams specification for which the payment will be made at the prevailing discom store issue rates. 77 in rural area 78 pcc poles 9 mtr. long(200kg.) 79 erection & assembly of 2 pole structures ofof steel supports or of pcc poles in excavated pit in alignment afterchecking the same with plumb line. including fixing of top bracing of m.s. channels with pilot plates and clamps. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractoras per nigams specfication for which the payment will be made at the prevailing discom store issue rates. 80 pcc poles 9 mtr. long(200kg.) 81 erection & fixing of g.i.stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.the work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension.size of stay set/stay wire 82 6x5/8 with 7/10 swg stay wire 83 providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.(1.2x1.2 x2.1 m)/tower 84 fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub station. 85 fixing of guarding bracket arms with clamp on erected support as per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 86 11 kv line 87 fixing of earth wire clamp on erected supportas per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 88 fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. the nuts &bolts are to be provided by the contractor as per nigams specification for which payment will be made as perprevailing discom store issue rates. 89 11 kv line 90 fixing and assembly of disc. point channel pair with pilot plates & clamps on erected single pole structure as per design. the nuts & bolts are to be provided by the contractor as per nigams specification for which payment will be made as per prevailingdiscom store issue rates. 91 11 kv line 92 fixing of 11kv b&s/t&c type disc insulator of 11kv lines(each unit consiting of 1nos.disc.& 1set of h/ w ) on terminal point including fixing of hardware and strips. 93 fixing of 11 kv pininsulator with pins. 94 ssembly and installation of horn gap fuse set (set of 3 nos)on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. the nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing discom store issue rates. 95 11kv horn gap fuse set. 96 installation testing as per nigams norm & commissioning of11/0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on hv&lv side, crimping of lugs/clamping earth connections of body and neutral of transformer with wire/strip (as already provided with earthing) complete in all respect. the pg clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing discom store issue rates. 97 10 & 16 kva 98 25 & 40 kva 99 fixing of danger plates on supports/structure 100 fixing of pg clamp of weasel /rabbit conductor 101 laying, jointing , stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire/p.g. clamps aluminium jointing sleeves will be used for jointing the conductor. the line must stand at proper voltage on charging. the contractor will be provide p.g. clamps for which payment will be made as per prevailing discom store issue rates. 102 acsr rabbit 103 laying, jointing,stringing,tensioning and clamping of g.i.earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.the nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing discom store issue rates. 104 (b) in rural area 105 g.i.earth wire 8 swg 106 drawing & strining of g.i 4 wire over the guarding brackets for guarding of road crossing /p&t crossing/railway track crossing (for one span only)with cross g.i wire laces at an intraval of two meter each or required as per location using eye bolt nuts. 107 8 swg with laces of 10 swg 108 earthing of line for all type of supports as per rec construction standards using stay wire/gi wire with one pcs of m.s. rod 20mm dia each 3 meter long and driving into earth by mechanical means ms rod, ms flat & stay wire will be supplied by the contractor. ifmaterial is supplied by the contractor the payment will be made as per prevailing discom store issue rates.(in case of pcc poles earthing mustbe connected with earthwire already available on pcc pole at bottom) 109 earthing of 11/0.4 kv distribution transformer /sub station with 3 pieces of m.s. rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. the work includes flattening of top ends of m.s. rod drilling a hole of 9/16 dia. at flattened top and tightening of m.s. flat 50x6mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with m.s. rod. top end hole. the flat will also be welded with m.s. rod. the end will be connected to equipments as under as under in sequence. 110 fixing of three phase meter cummeter box(complete unit)at the premises of existing/new consumerswith 4 nos anchor fastners with rust proof size m 6x50 mm on the wall as per the positionof holes already provided on the meter box. the meter box must be housed perfectly vertical/plumb line,anchor fasteners are to be supplied/provided by the contractor including safe carriage from s/d store to consumers site and depositing removed meter and meter box if any in s/d store). 111 in rural area 112 laying of 1100 volt heavy duty armoured xlpe cable of aluminum coudctor of following size conforming to is: 7098 (pt i) (latest amended) overhead service line from pole to meter terminals for release of new lt connections/replacement of damaged/obsolete service line (except agriculture one). the cable must be fixed on wall with clamps /hooks properly at a interval of one meter. 113 4 core 16/25 sq. mm 114 fixing of 3 phase lt shunt capacitor (3/6/9/12kvar) near starterof motor for agriculature consumers to be fixed with ms clamp of shape of size 2x10mm having two nos.holes for fixing of lt capacitors besides starter of consumer with the help of two no.machine screw. the starter shall be connected using pvc sheathed single core of 4 sq.mm ai. cable conforming to relevant is. the wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with ms compoundpvc tape roll. the ends of wire shall be properly crimped with lugsthimble etc.all material shall be supplied by the contractor except lt shunt capacitor (the lt shunt capacitor shall be supplied by nigam) ...

Urban Improvement Trust - Rajasthan

32265199 various civil works and maintenance works in sub division i of division ii b ( arc ) civil worksclearing and grubbing road land including uprooting rank vegetation, grass, brush, shrubs, saplings and trees of girth upto 300mm, removal of stumps, disposal of unserviceable material and stacking of serviceable material upto 1000m from road boundary. (morth specification : clause 201).by manual means : in area of light jungle 2 clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared. 3 silt clearance of drains, channels and canals with lift 1.5 mtr. and lead up to 50 mtr. 4 earth work in excavation by mechanical means (hydraulic excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. all kinds of soils 5 add extra over item no. 1.8 and 1.9 (sechedule item no 1) for every additional lift of 1.5 m or part thereof : 6 above 1.50 to 3.00m 7 m 35,60mm thick to be used in light traffic (light traffic is defined as a daily traffic up to 150 commercial vehicles exceeding 30 kn laden weight, or an wquivalent up to 0.5 million standerd axles (msa) for a design life of 20 years (a standerd axle is defind as a single axle load of 81.6 kn ) like pedestrain plazes, shopping complexes ramps, car parks, office drveways , housing colonies , office complexes , rural roads with low volume traffic ,fram houses, beach sites, tourist resorts, local authority footwys ,residential roads, etc. 8 category bdenated only two side like i,z,t shape etc. as per irc sp 63:2004 9 random rubble dry stone kharanja under floor. 10 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. 11 m10 grade nominal mix, 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). 12 providing and laying in position specified grade ofcement concrete forall rcc structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. m20 grade nominal mix 13 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.m20 grade nominal mix 14 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.m20 grade nominal mix 15 centering and shuttering with plywood or steel plate including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 16 anti termite treatment of floor using imidacloprid 30.5% ec non repellent, odorless, low dose, environimentally safe terniticide with rapid action non corrosive stain free manufactured by bayer or equivalent company by drilling 12mm diameter holes 300mm apart injecting the emulsion as specified by the manufacturer and plugging with cement mortar 1:2 ( 1 cement : 2 coarse sand) in the whole floor area dpe 12mm dia termitube system with required number of junction boxes are to be installed. the termitube will run all along the perimeter wall both inside and outside. in the middle area the termitube to be installed at an interval of 1.00 mtr. or less both ways as required with sufficient number of junction boxes to pump the emulsion. after successful testing of termitube, pesticide emulsion of imidacloprid 30.5% ec mixed with water in the ration of 1:474 will be pumped by a motorized spray pump from the junction box in specified manner. the plinth area of the area treated will be measured for payment. 17 centering & shuttering with plywood or steel plate including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor three level for : 18 columns, pillars, posts and struts etc. 19 random rubble stone masonry for with hard stone in foundation and plinth in cement sand mortar above 30 cm thick wall in: 20 cement mortar 1:6 ( 1 cement : 6 sand). 21 cement mortar 1:4 ( 1 cement : 4 sand). 22 cement mortar 1:3 ( 1 cement : 3 sand). 23 random rubble stone masonry with hard stone in superstructure aboveplinth level and upto three levelabove 30cm. thick walls in : 24 cement mortar 1:3 ( 1 cement : 3 sand). 25 cement mortar 1:4 ( 1 cement : 4 sand). 26 cement mortar 1:6 ( 1 cement : 6 sand). 27 pointingonstonemasonryincementsandmortar 1:3 (1 cement : 3 sand) : 28 flush / ruled/ struck or weathered pointing. 29 providing and laying damp proof course with cement concrete grade m 150 (1 : 2 : 4) mortar prepared with 1% solution of water proof compound complete and not applying 2 coats of hot bitumen complete as per specifications. 75mm thick 30 50mm thick 31 75 mm thick 32 centering & shuttering with plywood or steel plate including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor three level for : 33 suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 34 providing and fabricating reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. 35 thermo mechanically treated bars (conforming of relevent is code) 36 flyash flyash brick work with flyash flyash bricks of class designation 75 in superstructure above plinth level upto floor three level in all shapes and sizes in : 37 cement mortar 1 : 4 (1 cement : 4 coarse sand) 38 cement mortar 1 : 6 (1 cement : 6 coarse sand) 39 half flyash brick masonry in foundation & plinth using flyash bricks of designation 75 40 cement mortar 1 : 4 (1 cement : 4 coarse sand) 41 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 42 12mm thick. 43 20mm thick. 44 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3 fine sand) 45 making grooves as per design in plaster 10mm to 20mm wide. 46 providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete 47 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : 48 two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect. 49 painting exterior surface ofwallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect. 50 new work 51 providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide 52 painting with synthetic enamel paint of approved brand and manufacture togive an even shade : 53 two or more coats on new work 54 150cm high fencing with angle iron 50x50x6mm. placed at every 3mtr. apart 30cm. in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with 50x50x6mm. angle iron provided with 6 horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed with g.i. staples including earth work in excavation etc. complete. 55 grading roof for water proofing treatment withwater proffing compound 56 cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 57 providing and fixing pressed steel door frames confirming to is 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike plate and shock absorbers as specified and applyinga coat of approved steel primer after pre treatment of the surface including filling with cc 1:2:4(m15 grade) complete as directed by engineer in charge : 58 profile b 59 providing and fixing external grade board solid core single leaf flush door shutters isi 2202 67 marked using phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure a: 30 mm thick . 60 decorative teak veneer both side 61 providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate z sections and other sections of approved make conforming to is :733 and is :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required pvc/neoprene felt etc. aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle aluminium snap beading for glazing /paneling , c.p. brass/ stainless steel screws al. tower bolt & al. handle & al. aldrop etc.,all complete as per architectural drawings and thedirections of engineer in – charge .(glazing and paneling to be paid for separately). : for fixed portion 62 polyester powder coating aluminum( minimum thickness of powder coating 50 micron) 63 providing and fixing of plastic shutter infill made from extruded multi chamber hollow p.v.c. section having cross section of 200 x 20 x 1 mm and shutter frame made from extrude p.v.c. section in the configuration of double walled c section having an overall cross section of 40 x 37 mm and door fittings such as hinges, aldrop, handles, stopper, locking bolt will be provided. 64 providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (is 1038 1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :partly fixed and partly openable [ fixed area not to exceed 33%] 65 for shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). 66 polyester powder coating aluminum( minimum thickness of powder coating 50 micron) 67 providing and fixing superior quality like hardvyn or equivalent hydraulic door closure. 68 providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to is : 13753 & is :15622 of size 300mm x 450mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 69 providing and fixing 1st quality mat finished ceremic tile size 300x300mm confirmingto is : 13755 and is : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 70 providing and fixing 15 to 20 mm thick granite stone slab mirror polished and machine edge cut in walls, pillars, steps, shelves, sills counters, floors etc. laid on 12 mm (av.) thick base of cement mortar 1 : 3 (1 cement : 3 coarse sand) jointing with white cement mortar 1 : 2 (1 white cement : 2 marble dust) with pigment to match the shade of the granite slab complete including rubbing and polishing of : 71 good quality south black above 3601 cm2 slabs 72 extra for providing edge moulding to 15 18mm thick marble/ granite stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 73 granite work (full edge moulding ) 74 p & f 1st quality heavy duty vitrified glazed mat tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to is 15622 of approved make in all colour and shade, laid with 20 mm thick cm 1: 4 including grounting the joints with white cement and matching pigment etc complete. 75 size600 mm x 1200mm 76 providing & fixingbrown kota/ mandana / dholpur/ slate stone incladding / flooring structuralbase with white cement & tinex chemical& ss clamp and fasteners (of approved brand) laid and jointed with white cement slurry mixed with pigment to match the shade of the slab as per drawing attachedcomplete in all respect as per direction of engineer in charge & architect with all lead & lift. the stone measurement will be done of outer most dimension. thickness of stone 25 30mm. 77 polished blue kota stone flooring skirting, laid over 20 mm thick base of c.m. 1 : 4 and jointed with grey cement slurry to match the shade of the slab including rubbing and polishing complete :for area of each slab from 901 to 2000 sq.cm : 78 25 mm thick slab. 79 s/f of fire bricks on edg flooring with fire bricks suitable for 1300 degree centigrade safe working temperature as per is :8 specification laid on & filling of joint by fire resistant mortar/adhesive of required thickness as per directed on a bed of 20 mm thick 1:2 cement mortar of bricks 9 x 4.5x 3 (rate approved year 2008) 80 providing and fixing of glass moisac tiles ( bisseze marke ) size 20 x 20 x 4 mm applied with aaproved adhesive as per specification and direction of engineer in charge 81 providing and fixing staincase railing 90 cm high from nosing of made offollowing specifications. 82 50 mm outer dia (2 mm thick) s.s. pipe hand rail. 83 40 mm outer dia (2 mm thick) s.s. pipe baluster @ 1.00 mtr. 84 4 nos. 20 mm fs. s pipe intermediate runners parallel to hand. 85 s.s. shoe 1.60 mm thick 75 mm outer dia. at each baluster 86 baluster to be welded with s.s. plate 50 mm dia (3 mm thick) anchored in c.c. block with suitable dash fastners 87 50 mm dia & 2 mm thick s.s. pipe for start and end vertical ornamental posts to be provided as per direction of engineer in charge 88 the stainless steel work shall be brushed steel finish with all joints/welds properly grinded to final finish. the stainless steel shall be 304 grade and shall confirm to relevant i.s. 89 providing and fixing steel gate grating and grills made of angles, tees, square bars or other flats black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide.extra if square,rectangular hollow tubularsections are used or grill made by flats only 90 decorative plaster work with spectrum textured coating as per approved colour and shade complete as per manufactures specifications. 91 grit textured @ 2.5 to 3.0 mm thick. 92 ornamental cement plaster in cement sand mortar1 : 4 making kangooras etc. as per jaipurpractice. 93 supplying and fixing machine cutdressed 75 mm pinksand stone (bansi paharpur) dasa/ coping wth ornamental shape having moulding and pan shape engraving as per required pattern with engraving depth of 5 mm (average) in single piece of length 90 cm to be laid on cement mortar 1:4 (12 to 20mm thick) including pointing with admixture of pigment matching with the stone shade. 94 providing corrugated g.s. sheet roofing including vertical / curved surface fixed with polymer coated j or l hooks, bolts and nuts 8 mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces)excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required. 95 0.63 mm thick with zinc coating not less than 275 gm/m2 96 supply & spreading ofgood earth at site complete including loading unloading & transportation etc. 97 supply of dry manure including loading unloading,transportation & stacking at site. 98 farm yard manure(organic) 99 spreading of manure and good earth in required thickness (cost of manure and good earth to be paid separately). 100 laying of lawns including ploughing levelling breaking of clods manuring & removal of stones etc.(cost of manure or extra good earth to be paid seperately) maintenance of lawns for 30 daysor more till the grass forms a thick lawns free from weeds & fit fo 101 in rows 7.5 cms. apart in either direction 102 construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting by vibratory roller 8 10 tonne to meet requirement of table 300 2 including cost of compensation for earth taken from private land with lead upto 1 km as per morth specification : clause no. 305. 103 rough chisel dressed stone flooring over 20 mm (av.) thick base in cm 1 : 6 including pointing with cement mortar 1 : 2 (1 cement : 2 stone dust) with and admixture of pigment to match the shade of stone with joint thickness upto 15 mm : 35 mm thick red sand stone. 104 p & f european type white glazed vitreous china 1st quality double syphonic w.c (is :2556 mark) with p or s trap including cutting and making good the wall and floor 105 p & f indian type white glazed vitreous china 1st quality w.c. orissa pan (is :2556 mark) with 100 mm vitreous china p or s trap including cutting and making good the wall and floor: 106 size 580x440mm. 107 p & f low level flushing cistern of 10 ltr. capacity (is : 2556 mark) o9f approved make with colplete fitting ,c.i. brackets duly painted , brass ball cock with ball, (is :1703 mark)complete including cutting and making good the wall. 108 wvc with c.p. brass bend. 109 p & f wvc wash basin (1st quality, i.s. : 2556 mark) of approved make with c.i. brackets duly painted, 1 no. 15 mm c.p. pillar cock (is : 8934 mark) &32 mm c.p. brass waste coupling of approved make, 25 mm g.i. waste pipe complete including cutting & making good the wall.: 110 size 550 mm x 400 mm dia for counter top 111 1.0 mm thick salem stainless steel aisi 304 & is 13983 1994kitchen sink of approved make (nirali, neel – kanth, jaina, faber castell )with large waste coupling. 112 (24 x 18 x 8) (20x16x8) 113 p & f inlet connection (angle valves) superior quality, of approved make, for wash basin, gyser etc. 114 c.p. inlet connection 15mm.brass (is : 8931 marked) with 37 cm long pipe and nut. 115 p & f pvc storage tank isi marked (is : 12701) indicating thebis license no),of approved make with cover, 25mm dia 1m long g.i. over flow pipe & 25 cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 116 1000 litres capacity. 117 providing and fixingsuperior quality (jaguar contiental ) cp brassfittings complete as per direction of ei 118 bib cock with long thread 15 mm nominal size 119 brass / gunmetalhalf turnwt. 1 kg.ofapprovedquality / make,25mmnominalbore. 120 p & f full way valve (is:778 mark) or wheel valve of approved make 121 gun metal 32mm nominal bore. 122 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. (concealed work including cutting chases and making good the walls etc.,) 123 20mm nominal outer dia pipes 124 32mm nominal outer dia pipes 125 p&f rigid pvc pipe (is:4985 mark) class ii/ (4 kg. /cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 126 110 mm dia 127 160 mm dia 128 p&f rigid pvc pipe fittings (is: 4985 mark) of approved quality / make including joining the pipe with solvent cement rubber ring and lubricant: 129 coupler (socket) 130 110mm dia 131 160 mm dia 132 plain tee 133 110mm dia 134 160mm dia 135 door tee 136 110mm dia 137 bend 45 138 110mm dia 139 vent cowel 140 110mm dia 141 door bend (left & right) 142 110mm dia 143 pipe clip 144 110mm dia 145 plain floor trap 146 110mm dia 147 p trap 148 110mm dia 149 socket plug 150 110mm dia 151 door cap 152 110mm dia 153 construction of chamber in all type of soil with 300 mm thick masonry in cm 1:6 m 10 cm thick c.c. 1:5:10 in foundation, 20mm thick insider plaster in cm 1:6, finished with floating neat cement, 50mm thick m 15 grade c.c. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. 154 do size 450 x 450mm depth upto0.5 m cement cover with frame 155 wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade (is:694) ofapproved make in surface / recessed isi marked medium duty pvc conduit & its accessories, round tiles,hot dipped galvanized modular box with earth terminal, 6 a modular switch,modular plate with grid plate,screws,making connections, testing etc. as required. 156 short point (up to 3 mtr.) 157 medium point (up to 6 mtr.) 158 long point(up to 10 mtr..) 159 wiring of twin control light point with 1.5 sq.mm fr pvc insulated unsheathed flexiable copper conductor 1.1 kv grade and 1.5 sq.mm.fr pvc insulated unsheathed flexiable copper earth conductor 1.1 kv grade(is: 694) of approved make in surface/ recessd isi marked medium duty pvc conduit & its accessories, round tiles, 18 swg m.s. box with earthing terminal, 6 amp two way switch, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. 160 medium point (up to 6 mtr) 161 wiring of 3 pin 6 amp light plug point with 1.5 sq.mm fr pvc insulated unsheathed flexiable copper conductor 1.1 kv grade and 1.5 sq.mm.fr pvc insulated unsheathed flexiable copper conductor 1.1 kv grade(is: 694) of approved make in surface/ recessd isi marked medium duty pvc conduit & its accessories, round tiles, 18 swg m.s. box with earthing terminal, 6 amp switch & 6 amp socket, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. 162 on board 163 medium point (up to 6 mtr) 164 long point (up to 10 mtr) 165 s&f following sizes (dia.) of isi marked medium duty pvc conduit along with accessories in surface / recessed using saddles, clamps, fastener as required includingcutting the wall, covering conduit and making good the same as required. 166 25 mm 167 32 mm 168 50 mm 169 supplying and fixing of power plug point modular accessories on hot dipped galvanized modular on surface or in recessed with suitable size of grid plate with cover plate including cost ofmodular 16 amp. switch and socket outlet, making connection , testing , etc. as required. 170 p&f metal clad industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in sheet steel enclosure (without mcb) including making connections, testing etc.as required 171 single / double pole(three pin) 172 32 a 173 providing & fixing isi marked 6 amp bakelite batten/angle holder including making connection testing etc. as required. 174 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existingsurface or recessed conduit/casing capping including making connections etc. as required. 175 2 x 2.5 sq. mm. + 1x1.5sqmm 176 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 177 p&f 240/415 v ac mcb with positive isolation of breaking capacity not less than 10 ka (b/ c/ d tripping characteristic) isi marked is 8828(1996)]/ conforming to iec 60898 in existing board/sheets including making connections, testing etc. as required. 178 single pole mcb 179 6 a to 32 a rating 180 four pole mcb 181 40 a 63 a rating 182 four pole mcb 183 6 a to 32 a rating 184 p&f recessed/ surface mounting heavy duty horizontal type sheet steel distribution board phophatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar,masking sheet, conforming to is13032 & is8623 including making internal dbterminations with copper lugs , testing etc. as required. 185 double door (single phase) 186 12 way 187 double door (three phase) 188 8 way 189 p/laying p.v.c./ xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved makein ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 190 25.0 sq.mm 191 4 core 192 50.0 sq.mm 193 120.0 sq,mm 194 3.5 core 195 150.0 sq,mm 196 supplying and making one end termination with heavy duty single compression brass gland sibg type, heavy duty aluminium lugs duly crimped with crimping tool, pvc tape etc for following size of armoured pvc insulated & pvc sheathed/ xlpe aluminium conductor cable of 1100 volt grade as required of size. 197 3.5 x 120.0 sq.mm 198 4 x 25.0 sq.mm 199 p/laying p.v.c./ xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with copper conductor of is:1554 p i / is :7098 p i of group 1 of approved makein ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 200 10.0 sq.mm 201 4 core 202 supplying and making one end termination with heavy duty single compression brass gland sibg type, heavy duty copper lugs duly crimped with crimping tool, pvc tape etc for following size of armoured pvc insulated & pvc sheathed/ xlpe aluminium conductor cable of 1100 volt grade as required of size. 203 4 x 10.0 sq.mm 204 sitc of wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel made out of crca sheet , required hardware,duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panel in desired shadethe panel having pu/ neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate m.s. base channel ,hinged door with locking arrangement for equipment/switchgear. thickness of sheet shallnot be less than 1.6 mm up to 600 mm length / widthof any compartment and be of 2.0 mm above 600 mm. load bearing structure shall beof 2.0 mmthick sheet supported by base m.s. channel if required . side walls and cable alley compartments having bolted type doors with / withoutdetachable extension type structure. (only outer area on all sides shall be measured & panel to be fabricated from cpri approved fabricator) 205 supplying and fixing of aluminium / copper bus barby means of smc / dmc type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. 206 electrolytic grade aluminium bus bar 207 sf of (0 500) v range volt meter on existing panel , making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required. 208 analog type ( 96mm x 96mm ) 209 sf of ct operated direct reading typeampere meter on existing panel , making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required. 210 analog type ( 96mm x 96mm ) 211 below 500 a 212 sf ofcurrent transformer, with all necessary support in existing panel including connection etc. as required . 213 up to 150/5 ratio, 10 va, class 1 accuracy 214 sf of selector switch of 10 a for voltmeter (4 position ) including making connection etc.as required . 215 sf of ct linked selector switch of 10 aforampere meter (4 position ) including making connection etc.as required . 216 sf of110/220 v, led (22.5 mm dia ) indicatinglamp with integral circuit, terminal block, including connection etc. as required. 217 red/yellow/green colour 218 supplying and drawing fr pvc insulated & unsheathed flexiable copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. 219 1 x 1.5 sq.mm 220 1 x 2.5 sq.mm 221 1 x 4.0 sq.mm 222 1 x 6.0 sq.mm 223 sitc of self healing mpp/mp type shunt capacitor (banks) conforming to is:13340 41 / iec :831 1&2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( psd ) and shall have dissipation factor less than 0.0025 at 50 hz and total wattage loss less than 0.5 watt per kvar . including making connections with suitable capacity conductors/cables testing etc. as required. 224 heavy duty three phase 440 v , 50 hz capacitor (bank) 225 sitc of microprocessor based three phase sensingpower factor correction relay having following sensing capacitysecondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall havedigit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like kw, kva, kvar,metering facility as required. 226 6 to 8 stage 227 sensitivity upto 50 milli amp 228 p & f ofcam operated rotary switchs on existing panel with 2 way and off postion 229 one pole 230 16 amp 231 p & f of440 volt 3 pole capacitor(ac 6 b ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current, conforming to is:13947 4 1/iec:947 4 1, din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. 232 up to 6 kvar 233 7 to 10 kvar 234 p&f 240/415 v ac mcb with positive isolation of breaking capacity not less than 10 ka (b/ c/ d tripping characteristic) isi marked is 8828(1996)]/ conforming to iec 60898 in existing board/sheets including making connections, testing etc. as required. 235 triple pole mcb 236 6 a to 32 a rating 237 p&f on load change over switch, front handle operated, four pole 415 v conforming to is:13947 p iii including connections , testing etc. as required in the following rating: 238 open execution type 239 200 amp 240 sitc of quick make and quick break4 polecurrent limiting mccb having following current rating, short circuitbreaking capacityat 440/415 v, 50 hz; o/l & s/c settings and conforming to is 60947 2 / iec 60947 2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for uvr , shunt trip ,earth fault trip, push( test) to trip , including making connections with lugs & spreaders,etc. as required. 241 with thermal magnetic release 242 up to 160 amp , 25 ka, adjustable o/l & fixed s/c setting, ics = 100 % icu 243 plate earthing as per is:3043 withcopper earth plate of size 600mm x 600mm x 3.0mm by embodying3 to 4 mtr. below the ground level with 25mm dia. g.i. b class watering pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and c.c.finished chamber covered with hinged type with locking arrangement c.i. cover,c.i. frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. 244 s & laying following size earth wire/stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. 245 8 swg copper wire 246 providing & fixing of heavy duty capacitor start 900/1400 rpm single phase isi marked exhaust fan is:2312 marked in existing opening making connections, testing etc. as required 247 300 mm sweep (900/1400 rpm) 248 p & f double ball bearing capacitor start, aluminium body & blade ceilingfanwith down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. 249 1400 mm sweep 250 p & f of ip 20 led tube light 20 watt with external batten made from crca sheet steel suitable to replace t 8/t 12 tube light, integral driver, 2000 luman + 5% tolerarrce system luman efficiacy of 100 lm/ watt minimum expected life time of 25000 burning hours, cct 5700 k ansi, cri 80, driver efficiency >85%, life expectancy of driver rnin 30000 hrs. pf 0,95 at full load/ 230 volt ac. 251 p & laying xlpe insulated is:7098/ii/85 of group1 and approved make h.t.cable for working voltage 11 k.v.earthed direct in ground including excavation of 30cmx100cm size trench, 25cmlayer of river sand, iind class bricks covering, refilling earth, compaction of earth, making necessary connection testing etc.as required of size. 252 3 core 185.0 sq.mm ...

Jodhpur Vidyut Vitaran Nigam Limited - Rajasthan

32159247 supply, erection, installation and commissioning of material / equipment for the work of release of 5494 nos. ag connection in fy 2022_23 on turnkey basis in suratgarh division under sri ganganagar circle of jodhpur discom against tntw a. 11 kv new line ( 1836.80 km ) 2 supply of 33kv lattice structure 36 long with cross arms & top hamper with nut bolt single circuit 3 supply of pcc pole 9.0 mtr. long working load 200 kg. 4 supply of 11kv cross arm and top hamper with clampsmade of ms angle 65x65x6mm, clamp 50x6 mm, earth clamp 50x6 mm weight ( 13.797 kg. ) approx 5 supply of guard bracket 2.21 mtr long made from 75 x 40 x 6 mm ms channel ( weight 25 kg. approx. of 2 no. ) for guarding 6 supply ofsuitable clamp made from 50x8 ms flat ( weight 2.8 kg. approx. of 2 no. ) for guarding 7 supply of 11 kv line dp structure without pcc poles 8 supply of 11 kv pin insulator 9 supply of 11 kv gi pin 10 supply of 11 kv disc insulator ( t&c type, 45 kn ) 11 supply of 11 kv disc hardware ( t&c type, 45 kn ) 12 supply of overhead aluminium coredsteel reinforced ( acsr ) rabbit conductor 13 supply of overhead aluminium coredsteel reinforced ( acsr ) weasel [ 30 sq.mm ( 6+1 ) / ( 2.59+2.59 ) mm ] conductor 14 supply of pg clamp for weasel conductor 15 supply ofg.i.stay set 20*2400 mm for lattice tower 16 supply of g.i.stay wire 7 / 8 swg ( 7 / 4 mm ) for lattice tower 17 supply of 33 kv stay insulator for lattice tower 18 supply of stay clamp made of ms flat 50x10 mm ( weight approx 0.616 kg ) 19 supply of m.s rod type earthing 20 mm dia, 3 mtr. long for 20 supply ofg.i.stay set 16*1800 mm 21 supply of g.i.stay wire 7 / 10 swg ( 7 / 3.15 mm ) 22 supply of 11 kv stay insulator 23 supply of stay clamp made of ms flat 50x10 mm suitable for 9 mtr. pcc pole, w.l. 200 kg. 24 supply of g.i. wire 8 swg for earth wire and guarding 25 supply of m.s, nuts & bolts, size, 16 mm ( assorted length ) 26 supply of 11kv danger plates 27 supply of ms channel 75x40x6 mm for extension bracket for 9 mtr. long pole 28 supply of 1.4 mtr long ms channel bracket with clamp ( cut point channel & tee off ) 29 b. 11 / 0.4 kv s / s kv ( 2296 nos. ) 30 supply of pcc pole 9.0 mtr. long working load 200 kg. 31 supply of 11 kv pin insulator 32 supply of 11 kv gi pin 33 supply of overhead aluminium coredsteel reinforced ( acsr ) weasel [ 30 sq.mm ( 6+1 ) / ( 2.59+2.59 ) mm ] conductor 34 supply of 11 / 0.4 kv, 16 kva, al wound, completely self protected ( csp ) distribution transformerwith provision of lt bushing box with all fittings and accessories confirming to technical specification. ( unit rate taken from jvvnl boq ) 35 supply of 11 / 0.4 kv, 25 kva, al wound, completely self protected ( csp ) distribution transformerwith provision of lt bushing box with all fittings and accessories confirming to technical specification. ( unit rate taken from jvvnl boq ) 36 supply of 11 / 0.4 kv, 40 kva super transformer, al wound, conventional outdoor type distribution transformers with all fittings and accessories confirming to technical specification 37 supply of 11 / 0.4 kv, 63 kva super transformer, al wound, conventional outdoor type distribution transformers with all fittings and accessories confirming to technical specification 38 supply of 11 / 0.4 kv super transformer, 100 kva, al wound, conventional outdoor type distribution transformers with all fittings and accessories confirming to technical specification 39 supply of lt pvc 4 core 16 sqmm armoured cable 40 supply of 11 / 0.4 kv substation structure setonexisting poles in all respect with clamps as required made from m.s. channel 100x50 x6 mm and 75x40 mm, m.s. angle 50x50x6 and m.s. flat 50x6 mm and 50x8 mmweight ( 166.746 kgs. ) approx 41 supply of 11 kv 3 phase complete d.o fuse set with pi ( horngap fuse set ) 42 supply of 9 kv 10 ka distribution class lightening arrestors including hardware, nut, bolt & washers etc. 43 supply ofg.i.stay set 16*1800 mm 44 supply of g.i.stay wire 7 / 10 swg 45 supply of 11 kv stay insulator 46 stay clamp made of ms flat 50x6 mm suitable for 9 mtr. pcc pole, w.l. 200 kg. 47 supply of 11 kv disc insulator ( t&c type, 45 kn ) 48 supply of 11 kv disc hardware ( t&c type, 45 kn ) 49 supply of m.s rod type earthing 20 mm dia, 3 mtr. long 50 supply of m.s, nuts & bolts, size, 16 mm ( assorted length ) 51 supply of 3 phase polycarbonate metering box ( pushfit type as per technical specifications & gtp ) ( unit rate taken from jvvnl purchase order ) 52 supply of 11kv danger plates...

Jodhpur Vidyut Vitaran Nigam Limited - Rajasthan

32159238 supply, erection, installation and commissioning of material/ equipment for the work of release of 2686 nos. ag connection in fy 2022_23 on turnkey basis in mathania division under jodhpur district circle of jodhpur discom against tntw 614 a. 11 kv new line (1836.80 km) 2 supply of 33kv lattice structure 36 long with cross arms & top hamper with nut bolt single circuit 3 supply of pcc pole 9.0 mtr. long working load 200 kg. 4 supply of 11kv cross arm and top hamper with clampsmade of ms angle 65x65x6mm, clamp 50x6 mm, earth clamp 50x6 mm weight (13.797 kg.) approx 5 supply of guard bracket 2.21 mtr long made from 75 x 40 x 6 mm ms channel (weight 25 kg. approx. of 2 no.) for guarding 6 supply ofsuitable clamp made from 50x8 ms flat (weight 2.8 kg. approx. of 2 no.) for guarding 7 supply of 11 kv line dp structure without pcc poles 8 supply of 11 kv pin insulator 9 supply of 11 kv gi pin 10 supply of 11 kv disc insulator (t&c type, 45 kn) 11 supply of 11 kv disc hardware (t&c type, 45 kn) 12 supply of overhead aluminium coredsteel reinforced (acsr) rabbit conductor 13 supply of overhead aluminium coredsteel reinforced (acsr) weasel [30 sq.mm (6+1)/(2.59+2.59) mm] conductor 14 supply of pg clamp for weasel conductor 15 supply ofg.i.stay set 20*2400 mm for lattice tower 16 supply of g.i.stay wire 7/8 swg ( 7/ 4 mm) for lattice tower 17 supply of 33 kv stay insulator for lattice tower 18 supply of stay clamp made of ms flat 50x10 mm(weight approx 0.616 kg) 19 supply of m.s rod type earthing 20 mm dia, 3 mtr. long for 20 supply ofg.i.stay set 16*1800 mm 21 supply of g.i.stay wire 7/10 swg ( 7/ 3.15 mm) 22 supply of 11 kv stay insulator 23 supply of stay clamp made of ms flat 50x10 mm suitable for 9 mtr. pcc pole, w.l. 200 kg. 24 supply of g.i. wire 8 swg for earth wire and guarding 25 supply of m.s, nuts & bolts, size, 16 mm(assorted length) 26 supply of 11kv danger plates 27 supply of ms channel 75x40x6 mm for extension bracket for 9 mtr. long pole 28 supply of 1.4 mtr long ms channel bracket with clamp (cut point channel & tee off) 29 b. 11/0.4 kv s/s kv (2296 nos.) 30 supply of pcc pole 9.0 mtr. long working load 200 kg. 31 supply of 11 kv pin insulator 32 supply of 11 kv gi pin 33 supply of overhead aluminium coredsteel reinforced (acsr) weasel [30 sq.mm (6+1)/(2.59+2.59) mm] conductor 34 supply of 11 /0.4 kv, 16 kva, al wound, completely self protected (csp) distribution transformerwith provision of lt bushing box with all fittings and accessories confirming to technical specification. (unit rate taken from jvvnl boq) 35 supply of 11 /0.4 kv, 25 kva, al wound, completely self protected (csp) distribution transformerwith provision of lt bushing box with all fittings and accessories confirming to technical specification. (unit rate taken from jvvnl boq) 36 supply of 11 /0.4 kv, 40 kva super transformer, al wound, conventional outdoor type distribution transformers with all fittings and accessories confirming to technical specification 37 supply of 11 /0.4 kv, 63 kva super transformer, al wound, conventional outdoor type distribution transformers with all fittings and accessories confirming to technical specification 38 supply of 11 /0.4 kv super transformer, 100 kva, al wound, conventional outdoor type distribution transformers with all fittings and accessories confirming to technical specification 39 supply of lt pvc 4 core 16 sqmm armoured cable 40 supply of 11/0.4 kv substation structure setonexisting poles in all respect with clamps as required made from m.s. channel 100x50 x6 mm and 75x40 mm, m.s. angle 50x50x6 and m.s. flat 50x6 mm and 50x8 mmweight(166.746 kgs.) approx 41 supply of 11 kv 3 phase complete d.o fuse set with pi (horngap fuse set) 42 supply of 9 kv 10 ka distribution class lightening arrestors including hardware, nut, bolt & washers etc. 43 supply ofg.i.stay set 16*1800 mm 44 supply of g.i.stay wire 7/10 swg 45 supply of 11 kv stay insulator 46 stay clamp made of ms flat 50x6 mm suitable for 9 mtr. pcc pole, w.l. 200 kg. 47 supply of 11 kv disc insulator (t&c type, 45 kn) 48 supply of 11 kv disc hardware (t&c type, 45 kn) 49 supply of m.s rod type earthing 20 mm dia, 3 mtr. long 50 supply of m.s, nuts & bolts, size, 16 mm(assorted length) 51 supply of 3 phase polycarbonate metering box (pushfit type as per technical specifications & gtp) (unit rate taken from jvvnl purchase order) 52 supply of 11kv danger plates ...

Jodhpur Vidyut Vitaran Nigam Limited - Rajasthan

32159220 supply, erection, installation and commissioning of material / equipment for the work of release of 3358 nos. ag connection in fy 2022_23 on turnkey basis in a. 11 kv new line ( 1836.80 km ) 2 supply of 33kv lattice structure 36 long with cross arms & top hamper with nut bolt single circuit 3 supply of pcc pole 9.0 mtr. long working load 200 kg. 4 supply of 11kv cross arm and top hamper with clampsmade of ms angle 65x65x6mm, clamp 50x6 mm, earth clamp 50x6 mm weight ( 13.797 kg. ) approx 5 supply of guard bracket 2.21 mtr long made from 75 x 40 x 6 mm ms channel ( weight 25 kg. approx. of 2 no. ) for guarding 6 supply ofsuitable clamp made from 50x8 ms flat ( weight 2.8 kg. approx. of 2 no. ) for guarding 7 supply of 11 kv line dp structure without pcc poles 8 supply of 11 kv pin insulator 9 supply of 11 kv gi pin 10 supply of 11 kv disc insulator ( t&c type, 45 kn ) 11 supply of 11 kv disc hardware ( t&c type, 45 kn ) 12 supply of overhead aluminium coredsteel reinforced ( acsr ) rabbit conductor 13 supply of overhead aluminium coredsteel reinforced ( acsr ) weasel [ 30 sq.mm ( 6+1 ) / ( 2.59+2.59 ) mm ] conductor 14 supply of pg clamp for weasel conductor 15 supply ofg.i.stay set 20*2400 mm for lattice tower 16 supply of g.i.stay wire 7 / 8 swg ( 7 / 4 mm ) for lattice tower 17 supply of 33 kv stay insulator for lattice tower 18 supply of stay clamp made of ms flat 50x10 mm ( weight approx 0.616 kg ) 19 supply of m.s rod type earthing 20 mm dia, 3 mtr. long for 20 supply ofg.i.stay set 16*1800 mm 21 supply of g.i.stay wire 7 / 10 swg ( 7 / 3.15 mm ) 22 supply of 11 kv stay insulator 23 supply of stay clamp made of ms flat 50x10 mm suitable for 9 mtr. pcc pole, w.l. 200 kg. 24 supply of g.i. wire 8 swg for earth wire and guarding 25 supply of m.s, nuts & bolts, size, 16 mm ( assorted length ) 26 supply of 11kv danger plates 27 supply of ms channel 75x40x6 mm for extension bracket for 9 mtr. long pole 28 supply of 1.4 mtr long ms channel bracket with clamp ( cut point channel & tee off ) 29 b. 11 / 0.4 kv s / s kv ( 2296 nos. ) 30 supply of pcc pole 9.0 mtr. long working load 200 kg. 31 supply of 11 kv pin insulator 32 supply of 11 kv gi pin 33 supply of overhead aluminium coredsteel reinforced ( acsr ) weasel [ 30 sq.mm ( 6+1 ) / ( 2.59+2.59 ) mm ] conductor 34 supply of 11 / 0.4 kv, 16 kva, al wound, completely self protected ( csp ) distribution transformerwith provision of lt bushing box with all fittings and accessories confirming to technical specification. ( unit rate taken from jvvnl boq ) 35 supply of 11 / 0.4 kv, 25 kva, al wound, completely self protected ( csp ) distribution transformerwith provision of lt bushing box with all fittings and accessories confirming to technical specification. ( unit rate taken from jvvnl boq ) 36 supply of 11 / 0.4 kv, 40 kva super transformer, al wound, conventional outdoor type distribution transformers with all fittings and accessories confirming to technical specification 37 supply of 11 / 0.4 kv, 63 kva super transformer, al wound, conventional outdoor type distribution transformers with all fittings and accessories confirming to technical specification 38 supply of 11 / 0.4 kv super transformer, 100 kva, al wound, conventional outdoor type distribution transformers with all fittings and accessories confirming to technical specification 39 supply of lt pvc 4 core 16 sqmm armoured cable 40 supply of 11 / 0.4 kv substation structure setonexisting poles in all respect with clamps as required made from m.s. channel 100x50 x6 mm and 75x40 mm, m.s. angle 50x50x6 and m.s. flat 50x6 mm and 50x8 mmweight ( 166.746 kgs. ) approx 41 supply of 11 kv 3 phase complete d.o fuse set with pi ( horngap fuse set ) 42 supply of 9 kv 10 ka distribution class lightening arrestors including hardware, nut, bolt & washers etc. 43 supply ofg.i.stay set 16*1800 mm 44 supply of g.i.stay wire 7 / 10 swg 45 supply of 11 kv stay insulator 46 stay clamp made of ms flat 50x6 mm suitable for 9 mtr. pcc pole, w.l. 200 kg. 47 supply of 11 kv disc insulator ( t&c type, 45 kn ) 48 supply of 11 kv disc hardware ( t&c type, 45 kn ) 49 supply of m.s rod type earthing 20 mm dia, 3 mtr. long 50 supply of m.s, nuts & bolts, size, 16 mm ( assorted length ) 51 supply of 3 phase polycarbonate metering box ( pushfit type as per technical specifications & gtp ) ( unit rate taken from jvvnl purchase order ) 52 supply of 11kv danger plates 53 note ( 1 ) the unit base rate for supply of material mentioned in column no. 5 is inclusive of gst @ 18% and freight, insurance & transportation charges of all items ( 2 ) the sucessful bidder shall furnish price break upin format provided by this office with acceptance of loi....

Jodhpur Vidyut Vitaran Nigam Limited - Rajasthan

32159214 supply, erection, installation and commissioning of material / equipment for the work of release of 2481 nos. ag connection in fy 2022_23 on turnkey basis in nokha, dist div ii division under bikaner district circle of jodhpur discom against a. 11 kv new line (1836.80 km) 2 supply of 33kv lattice structure 36 long with cross arms & top hamper with nut bolt single circuit 3 supply of pcc pole 9.0 mtr. long working load 200 kg. 4 supply of 11kv cross arm and top hamper with clampsmade of ms angle 65x65x6mm, clamp 50x6 mm, earth clamp 50x6 mm weight (13.797 kg.) approx 5 supply of guard bracket 2.21 mtr long made from 75 x 40 x 6 mm ms channel (weight 25 kg. approx. of 2 no.) for guarding 6 supply ofsuitable clamp made from 50x8 ms flat (weight 2.8 kg. approx. of 2 no.) for guarding 7 supply of 11 kv line dp structure without pcc poles 8 supply of 11 kv pin insulator 9 supply of 11 kv gi pin 10 supply of 11 kv disc insulator (t&c type, 45 kn) 11 supply of 11 kv disc hardware (t&c type, 45 kn) 12 supply of overhead aluminium coredsteel reinforced (acsr) rabbit conductor 13 supply of overhead aluminium coredsteel reinforced (acsr) weasel [30 sq.mm (6+1)/(2.59+2.59) mm] conductor 14 supply of pg clamp for weasel conductor 15 supply ofg.i.stay set 20*2400 mm for lattice tower 16 supply of g.i.stay wire 7/8 swg ( 7/ 4 mm) for lattice tower 17 supply of 33 kv stay insulator for lattice tower 18 supply of stay clamp made of ms flat 50x10 mm(weight approx 0.616 kg) 19 supply of m.s rod type earthing 20 mm dia, 3 mtr. long for 20 supply ofg.i.stay set 16*1800 mm 21 supply of g.i.stay wire 7/10 swg ( 7/ 3.15 mm) 22 supply of 11 kv stay insulator 23 supply of stay clamp made of ms flat 50x10 mm suitable for 9 mtr. pcc pole, w.l. 200 kg. 24 supply of g.i. wire 8 swg for earth wire and guarding 25 supply of m.s, nuts & bolts, size, 16 mm(assorted length) 26 supply of 11kv danger plates 27 supply of ms channel 75x40x6 mm for extension bracket for 9 mtr. long pole 28 supply of 1.4 mtr long ms channel bracket with clamp (cut point channel & tee off) 29 b. 11/0.4 kv s/s kv (2296 nos.) 30 supply of pcc pole 9.0 mtr. long working load 200 kg. 31 supply of 11 kv pin insulator 32 supply of 11 kv gi pin 33 supply of overhead aluminium coredsteel reinforced (acsr) weasel [30 sq.mm (6+1)/(2.59+2.59) mm] conductor 34 supply of 11 /0.4 kv, 16 kva, al wound, completely self protected (csp) distribution transformerwith provision of lt bushing box with all fittings and accessories confirming to technical specification. (unit rate taken from jvvnl boq) 35 supply of 11 /0.4 kv, 25 kva, al wound, completely self protected (csp) distribution transformerwith provision of lt bushing box with all fittings and accessories confirming to technical specification. (unit rate taken from jvvnl boq) 36 supply of 11 /0.4 kv, 40 kva super transformer, al wound, conventional outdoor type distribution transformers with all fittings and accessories confirming to technical specification 37 supply of 11 /0.4 kv, 63 kva super transformer, al wound, conventional outdoor type distribution transformers with all fittings and accessories confirming to technical specification 38 supply of 11 /0.4 kv super transformer, 100 kva, al wound, conventional outdoor type distribution transformers with all fittings and accessories confirming to technical specification 39 supply of lt pvc 4 core 16 sqmm armoured cable 40 supply of 11/0.4 kv substation structure setonexisting poles in all respect with clamps as required made from m.s. channel 100x50 x6 mm and 75x40 mm, m.s. angle 50x50x6 and m.s. flat 50x6 mm and 50x8 mmweight(166.746 kgs.) approx 41 supply of 11 kv 3 phase complete d.o fuse set with pi (horngap fuse set) 42 supply of 9 kv 10 ka distribution class lightening arrestors including hardware, nut, bolt & washers etc. 43 supply ofg.i.stay set 16*1800 mm 44 supply of g.i.stay wire 7/10 swg 45 supply of 11 kv stay insulator 46 stay clamp made of ms flat 50x6 mm suitable for 9 mtr. pcc pole, w.l. 200 kg. 47 supply of 11 kv disc insulator (t&c type, 45 kn) 48 supply of 11 kv disc hardware (t&c type, 45 kn) 49 supply of m.s rod type earthing 20 mm dia, 3 mtr. long 50 supply of m.s, nuts & bolts, size, 16 mm(assorted length) 51 supply of 3 phase polycarbonate metering box (pushfit type as per technical specifications & gtp) (unit rate taken from jvvnl purchase order) 52 supply of 11kv danger plates 53 note (1)the unit base rate for supply of material mentioned in column no. 5 is inclusive of gst @ 18% and freight, insurance & transportation charges of all items(2) the sucessful bidder shall furnish price break upin format provided by this office with acceptance of loi. ...

Jodhpur Vidyut Vitaran Nigam Limited - Rajasthan

32159213 supply, erection, installation and commissioning of material / equipment for the work of release of 2296 nos. ag connection in fy 2022_23 on turnkey basis in jaisalmer division under jaisalmer circle of jodhpur discom against tntw 618 a. 11 kv new line (1836.80 km) 2 supply of 33kv lattice structure 36 long with cross arms & top hamper with nut bolt single circuit 3 supply of pcc pole 9.0 mtr. long working load 200 kg. 4 supply of 11kv cross arm and top hamper with clampsmade of ms angle 65x65x6mm, clamp 50x6 mm, earth clamp 50x6 mm weight (13.797 kg.) approx 5 supply of guard bracket 2.21 mtr long made from 75 x 40 x 6 mm ms channel (weight 25 kg. approx. of 2 no.) for guarding 6 supply ofsuitable clamp made from 50x8 ms flat (weight 2.8 kg. approx. of 2 no.) for guarding 7 supply of 11 kv line dp structure without pcc poles 8 supply of 11 kv pin insulator 9 supply of 11 kv gi pin 10 supply of 11 kv disc insulator (t&c type, 45 kn) 11 supply of 11 kv disc hardware (t&c type, 45 kn) 12 supply of overhead aluminium coredsteel reinforced (acsr) rabbit conductor 13 supply of overhead aluminium coredsteel reinforced (acsr) weasel [30 sq.mm (6+1)/(2.59+2.59) mm] conductor 14 supply of pg clamp for weasel conductor 15 supply ofg.i.stay set 20*2400 mm for lattice tower 16 supply of g.i.stay wire 7/8 swg ( 7/ 4 mm) for lattice tower 17 supply of 33 kv stay insulator for lattice tower 18 supply of stay clamp made of ms flat 50x10 mm(weight approx 0.616 kg) 19 supply of m.s rod type earthing 20 mm dia, 3 mtr. long for 20 supply ofg.i.stay set 16*1800 mm 21 supply of g.i.stay wire 7/10 swg ( 7/ 3.15 mm) 22 supply of 11 kv stay insulator 23 supply of stay clamp made of ms flat 50x10 mm suitable for 9 mtr. pcc pole, w.l. 200 kg. 24 supply of g.i. wire 8 swg for earth wire and guarding 25 supply of m.s, nuts & bolts, size, 16 mm(assorted length) 26 supply of 11kv danger plates 27 supply of ms channel 75x40x6 mm for extension bracket for 9 mtr. long pole 28 supply of 1.4 mtr long ms channel bracket with clamp (cut point channel & tee off) 29 b. 11/0.4 kv s/s kv (2296 nos.) 30 supply of pcc pole 9.0 mtr. long working load 200 kg. 31 supply of 11 kv pin insulator 32 supply of 11 kv gi pin 33 supply of overhead aluminium coredsteel reinforced (acsr) weasel [30 sq.mm (6+1)/(2.59+2.59) mm] conductor 34 supply of 11 /0.4 kv, 16 kva, al wound, completely self protected (csp) distribution transformerwith provision of lt bushing box with all fittings and accessories confirming to technical specification. (unit rate taken from jvvnl boq) 35 supply of 11 /0.4 kv, 25 kva, al wound, completely self protected (csp) distribution transformerwith provision of lt bushing box with all fittings and accessories confirming to technical specification. (unit rate taken from jvvnl boq) 36 supply of 11 /0.4 kv, 40 kva super transformer, al wound, conventional outdoor type distribution transformers with all fittings and accessories confirming to technical specification 37 supply of 11 /0.4 kv, 63 kva super transformer, al wound, conventional outdoor type distribution transformers with all fittings and accessories confirming to technical specification 38 supply of 11 /0.4 kv super transformer, 100 kva, al wound, conventional outdoor type distribution transformers with all fittings and accessories confirming to technical specification 39 supply of lt pvc 4 core 16 sqmm armoured cable 40 supply of 11/0.4 kv substation structure setonexisting poles in all respect with clamps as required made from m.s. channel 100x50 x6 mm and 75x40 mm, m.s. angle 50x50x6 and m.s. flat 50x6 mm and 50x8 mmweight(166.746 kgs.) approx 41 supply of 11 kv 3 phase complete d.o fuse set with pi (horngap fuse set) 42 supply of 9 kv 10 ka distribution class lightening arrestors including hardware, nut, bolt & washers etc. 43 supply ofg.i.stay set 16*1800 mm 44 supply of g.i.stay wire 7/10 swg 45 supply of 11 kv stay insulator 46 stay clamp made of ms flat 50x6 mm suitable for 9 mtr. pcc pole, w.l. 200 kg. 47 supply of 11 kv disc insulator (t&c type, 45 kn) 48 supply of 11 kv disc hardware (t&c type, 45 kn) 49 supply of m.s rod type earthing 20 mm dia, 3 mtr. long 50 supply of m.s, nuts & bolts, size, 16 mm(assorted length) 51 supply of 3 phase polycarbonate metering box (pushfit type as per technical specifications & gtp) (unit rate taken from jvvnl purchase order) 52 supply of 11kv danger plates 53 note (1)the unit base rate for supply of material mentioned in column no. 5 is inclusive of gst @ 18% and freight, insurance & transportation charges of all items(2) the sucessful bidder shall furnish price break upin format provided by this office with acceptance of loi. ...

Jodhpur Vidyut Vitaran Nigam Limited - Rajasthan

32159209 supply, erection, installation and commissioning of material / equipment for the work of release of 4666 nos. ag connection in fy 2022_23 on turnkey basis in nohar division under hanumangarh circle of jodhpur discom against tntw 622 11 kv new line (933.20 km) 2 supply of 33kv lattice structure 36 long with cross arms & top hamper with nut bolt single circuit 3 supply of pcc pole 9.0 mtr. long working load 200 kg. 4 supply of 11kv cross arm and top hamper with clampsmade of ms angle 65x65x6mm, clamp 50x6 mm, earth clamp 50x6 mm weight (13.797 kg.) approx 5 supply of guard bracket 2.21 mtr long made from 75 x 40 x 6 mm ms channel (weight 25 kg. approx. of 2 no.) for guarding 6 supply ofsuitable clamp made from 50x8 ms flat (weight 2.8 kg. approx. of 2 no.) for guarding 7 supply of 11 kv line dp structure without pcc poles 8 supply of 11 kv pin insulator 9 supply of 11 kv gi pin 10 supply of 11 kv disc insulator (t&c type, 45 kn) 11 supply of 11 kv disc hardware (t&c type, 45 kn) 12 supply of overhead aluminium coredsteel reinforced (acsr) rabbit conductor 13 supply of overhead aluminium coredsteel reinforced (acsr) weasel [30 sq.mm (6+1)/(2.59+2.59) mm] conductor 14 supply of pg clamp for weasel conductor 15 supply ofg.i.stay set 20*2400 mm for lattice tower 16 supply of g.i.stay wire 7/8 swg ( 7/ 4 mm) for lattice tower 17 supply of 33 kv stay insulator for lattice tower 18 supply of stay clamp made of ms flat 50x10 mm(weight approx 0.616 kg) 19 supply of m.s rod type earthing 20 mm dia, 3 mtr. long for 20 supply ofg.i.stay set 16*1800 mm 21 supply of g.i.stay wire 7/10 swg ( 7/ 3.15 mm) 22 supply of 11 kv stay insulator 23 supply of stay clamp made of ms flat 50x10 mm suitable for 9 mtr. pcc pole, w.l. 200 kg. 24 supply of g.i. wire 8 swg for earth wire and guarding 25 supply of m.s, nuts & bolts, size, 16 mm(assorted length) 26 supply of 11kv danger plates 27 supply of ms channel 75x40x6 mm for extension bracket for 9 mtr. long pole 28 supply of 1.4 mtr long ms channel bracket with clamp (cut point channel & tee off) 29 b. 11/0.4 kv s/s kv (4666 nos.) 30 supply of pcc pole 9.0 mtr. long working load 200 kg. 31 supply of 11 kv pin insulator 32 supply of 11 kv gi pin 33 supply of overhead aluminium coredsteel reinforced (acsr) weasel [30 sq.mm (6+1)/(2.59+2.59) mm] conductor 34 supply of 11 /0.4 kv, 16 kva, al wound, completely self protected (csp) distribution transformerwith provision of lt bushing box with all fittings and accessories confirming to technical specification. (unit rate taken from jvvnl boq) 35 supply of 11 /0.4 kv, 25 kva, al wound, completely self protected (csp) distribution transformerwith provision of lt bushing box with all fittings and accessories confirming to technical specification. (unit rate taken from jvvnl boq) 36 supply of 11 /0.4 kv, 40 kva super transformer, al wound, conventional outdoor type distribution transformers with all fittings and accessories confirming to technical specification 37 supply of 11 /0.4 kv, 63 kva super transformer, al wound, conventional outdoor type distribution transformers with all fittings and accessories confirming to technical specification 38 supply of lt pvc 4 core 16 sqmm armoured cable 39 supply of 11/0.4 kv substation structure setonexisting poles in all respect with clamps as required made from m.s. channel 100x50 x6 mm and 75x40 mm, m.s. angle 50x50x6 and m.s. flat 50x6 mm and 50x8 mmweight(166.746 kgs.) approx 40 supply of 11 kv 3 phase complete d.o fuse set with pi (horngap fuse set) 41 supply of 9 kv 10 ka distribution class lightening arrestors including hardware, nut, bolt & washers etc. 42 supply ofg.i.stay set 16*1800 mm 43 supply of g.i.stay wire 7/10 swg 44 supply of 11 kv stay insulator 45 stay clamp made of ms flat 50x6 mm suitable for 9 mtr. pcc pole, w.l. 200 kg. 46 supply of 11 kv disc insulator (t&c type, 45 kn) 47 supply of 11 kv disc hardware (t&c type, 45 kn) 48 supply of m.s rod type earthing 20 mm dia, 3 mtr. long 49 supply of m.s, nuts & bolts, size, 16 mm(assorted length) 50 supply of 3 phase polycarbonate metering box (pushfit type as per technical specifications & gtp) (unit rate taken from jvvnl purchase order) 51 supply of 11kv danger plates 52 note (1)the unit base rate for supply of material mentioned in column no. 5 is inclusive of gst @ 18% and freight, insurance & transportation charges of all items(2) the sucessful bidder shall furnish price break upin format provided by this office with acceptance of loi. ...

Jodhpur Vidyut Vitaran Nigam Limited - Rajasthan

32159208 supply, erection, installation and commissioning of material / equipment for the work of release of 2315 nos. ag connection in fy 2022_23 on turnkey basis in khajuwala division under bikaner district circle of jodhpur discom against tntw 620 a. 11 kv new line (694.50 km) 2 supply of 33kv lattice structure 36 long with cross arms & top hamper with nut bolt single circuit 3 supply of pcc pole 9.0 mtr. long working load 200 kg. 4 supply of 11kv cross arm and top hamper with clampsmade of ms angle 65x65x6mm, clamp 50x6 mm, earth clamp 50x6 mm weight (13.797 kg.) approx 5 supply of guard bracket 2.21 mtr long made from 75 x 40 x 6 mm ms channel (weight 25 kg. approx. of 2 no.) for guarding 6 supply ofsuitable clamp made from 50x8 ms flat (weight 2.8 kg. approx. of 2 no.) for guarding 7 supply of 11 kv line dp structure without pcc poles 8 supply of 11 kv pin insulator 9 supply of 11 kv gi pin 10 supply of 11 kv disc insulator (t&c type, 45 kn) 11 supply of 11 kv disc hardware (t&c type, 45 kn) 12 supply of overhead aluminium coredsteel reinforced (acsr) rabbit conductor 13 supply of overhead aluminium coredsteel reinforced (acsr) weasel [30 sq.mm (6+1)/(2.59+2.59) mm] conductor 14 supply of pg clamp for weasel conductor 15 supply ofg.i.stay set 20*2400 mm for lattice tower 16 supply of g.i.stay wire 7/8 swg ( 7/ 4 mm) for lattice tower 17 supply of 33 kv stay insulator for lattice tower 18 supply of stay clamp made of ms flat 50x10 mm(weight approx 0.616 kg) 19 supply of m.s rod type earthing 20 mm dia, 3 mtr. long for 20 supply ofg.i.stay set 16*1800 mm 21 supply of g.i.stay wire 7/10 swg ( 7/ 3.15 mm) 22 supply of 11 kv stay insulator 23 supply of stay clamp made of ms flat 50x10 mm suitable for 9 mtr. pcc pole, w.l. 200 kg. 24 supply of g.i. wire 8 swg for earth wire and guarding 25 supply of m.s, nuts & bolts, size, 16 mm(assorted length) 26 supply of 11kv danger plates 27 supply of ms channel 75x40x6 mm for extension bracket for 9 mtr. long pole 28 supply of 1.4 mtr long ms channel bracket with clamp (cut point channel & tee off) 29 b. 11/0.4 kv s/s kv (2315 nos.) 30 supply of pcc pole 9.0 mtr. long working load 200 kg. 31 supply of 11 kv pin insulator 32 supply of 11 kv gi pin 33 supply of overhead aluminium coredsteel reinforced (acsr) weasel [30 sq.mm (6+1)/(2.59+2.59) mm] conductor 34 supply of 11 /0.4 kv, 16 kva, al wound, completely self protected (csp) distribution transformerwith provision of lt bushing box with all fittings and accessories confirming to technical specification. (unit rate taken from jvvnl boq) 35 supply of 11 /0.4 kv, 25 kva, al wound, completely self protected (csp) distribution transformerwith provision of lt bushing box with all fittings and accessories confirming to technical specification. (unit rate taken from jvvnl boq) 36 supply of 11 /0.4 kv, 40 kva super transformer, al wound, conventional outdoor type distribution transformers with all fittings and accessories confirming to technical specification 37 supply of 11 /0.4 kv, 63 kva super transformer, al wound, conventional outdoor type distribution transformers with all fittings and accessories confirming to technical specification 38 supply of lt pvc 4 core 16 sqmm armoured cable 39 supply of 11/0.4 kv substation structure setonexisting poles in all respect with clamps as required made from m.s. channel 100x50 x6 mm and 75x40 mm, m.s. angle 50x50x6 and m.s. flat 50x6 mm and 50x8 mmweight(166.746 kgs.) approx 40 supply of 11 kv 3 phase complete d.o fuse set with pi (horngap fuse set) 41 supply of 9 kv 10 ka distribution class lightening arrestors including hardware, nut, bolt & washers etc. 42 supply ofg.i.stay set 16*1800 mm 43 supply of g.i.stay wire 7/10 swg 44 supply of 11 kv stay insulator 45 stay clamp made of ms flat 50x6 mm suitable for 9 mtr. pcc pole, w.l. 200 kg. 46 supply of 11 kv disc insulator (t&c type, 45 kn) 47 supply of 11 kv disc hardware (t&c type, 45 kn) 48 supply of m.s rod type earthing 20 mm dia, 3 mtr. long 49 supply of m.s, nuts & bolts, size, 16 mm(assorted length) 50 supply of 3 phase polycarbonate metering box (pushfit type as per technical specifications & gtp) (unit rate taken from jvvnl purchase order) 51 supply of 11kv danger plates 52 note (1)the unit base rate for supply of material mentioned in column no. 5 is inclusive of gst @ 18% and freight, insurance & transportation charges of all items(2) the sucessful bidder shall furnish price break upin format provided by this office with acceptance of loi. ...

Jaipur Vidyut Vitran Nigam Limited - Rajasthan

32072400 supply, erection, installation and commissioning of material equipment for the work of release of ag connection in fy 2022 23 on turnkey basis in respect of jaipur district circle lot i under the domain of jaipur discom against tn 523 supply of material (all material shall be supplied as per specification enclosed with the bidding documents): 2 9 mtr. long pcc poles of 200 kg working load with factor of safty 2.5. 3 33 kv s/c lattice structure (36 ungalvanised with 1 nos 33 kv cross arm(channel) with required nuts and bolts. 4 11/0.433 kv, 40 kva aluminium wound bis level 2 completely self protected (csp) distribution transformers with provisio of lt bushing box 5 25 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 6 16 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 7 galvanised steel stay set 16x1800 mm 8 11 kv stay insulator 9 galvanised steel stay wire 7/10 swg 10 stay set clamps suitable for 9 mtr. long pcc poles 11 h/w for disc insulators 45kn t&c type 12 disc insulators 45kn t&c type 13 m.s. nuts & bolts (assorted size) 14 acsr rabbit conductor 15 11 kv v cross arm with top hamper and clamps ( angle) 16 galvanized m.s. froged 11 kv pin 17 11 kv pin insulator 18 11/0.4 kv s/s structure set for 3 ph 40/25/ 16 kva transformer on double pole 19 horn gap fuse set with post insulator 11 kv 20 ms rod type earthing set with wire & clamp with following details(1 no. galvanised m.s. rod 20 mm dia electrodes having3 meter length, 2 nos. galvanised earthing clamp of m.s.flat of size 50x6 mm 220 mm length. one welded with earthelectrode and loose to be bolted; 2 nos. galvanised bolts, nuts and spring washers and g.i.wire size 8 swg of 15 meter length) 21 1.4 mtr channel 100x50x6 mm bracket with clamp 22 4c x 16 sq. mm. lt pvc insulated pvc sheathed cable (armoured) 23 m.s. angles 75 x 75 x 6 mm (for guarding) 24 three phase four wire whole current meter of rating 10 60 a having backlit lcd display with meter box (free issue). 25 m.s. channel 75 x 40 x 6 mm (for extension bracket) 26 lt shunt capacotors 3 kvar 27 lt shunt capacotors 6 kvar 28 danger plate 29 11 kv line dp set 30 p.g. clamps for rabbit 31 g.s. earth wire 8 swg 32 erection of material: 33 trimming of tree branches/plants and preparing route approchases for proposed line. 34 excavation of pit in hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 35 (a) height of poles/r.s.joist/m.s. rail /size of pit 36 9 mtr/ 1.2mx0.6mx1.50 m deep 37 (b) lattice tower /size of pit 38 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 39 (c)stay set/depth of pit 40 6x5/8 0.75x0.5x1.35m 41 excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 42 (a) height of poles/r.s.joist/m.s. rail /size of pit 43 9 mtr/ 1.2mx0.6mx1.50 m deep 44 (b) lattice tower /size of pit 45 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 46 (c)stay set/depth of pit 47 6x5/8 0.75x0.5x1.35m 48 safe carriage of pcc poles including loading / un loading 49 c) 9 mtr.long 200 kg. pcc pole 50 within10 kms. 51 above 10 km. & upto 30 km. add foreach km. or part thereof 52 above 30 km. add for each km. or part thereof (50 km) 53 safe carriage of steel( fabricated and unfabricated) i.e.m.s. rails, r.s.joists, m.s.channels, m.s.angles, m.s.flat, g.i.stay sets, g.i. stay wire, g.i.wire nut & bolts etc. and acsr conductor including loading and unloading and stacking in nigam store /at work site 54 within10 kms. 55 above 10 kms. & upto 30 kms. add for each km.or part thereof. 56 above 30 kms. add for each kms. or partthereof. (50 km) 57 safe carriage of insulator, hardware, cable etc.including loading/unloading and stacking in nigam.stores etc. 58 within10 kms. 59 above 10 kms. & upto 30 kms. add for each km.or part thereof. 60 above 30 kms. add for each kms.or part thereof. (50 km) 61 safe carriage of fabricated lattice towers structures and sub station structures type ab, ab beams, isolators structures etc. including loading/unloading and stacking in the nigam. stores / at work site. 62 within10 kms. 63 above 10 kms. & upto 30 kms. add for each km.or part thereof. 64 above 30 kms. add for each kms.or part thereof.(50 km) 65 safe carriage of 11/.4 kv 3 phase distribution transformer including loading/unloading and stacking in nigam.stores etc. 66 10 &16 kva 67 within10 kms. 68 above 10 kms. & upto 30 kms. add for each km.or part thereof. 69 above 30 kms. add for each kms.or part thereof. (50 km) 70 25 & 40 kva 71 within10 kms. 72 above 10 kms. & upto 30 kms. add for each km.or part thereof. 73 above 30 kms. add for each kms.or part thereof. (50 km) 74 erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. the support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item no. 5.6 the remaining portion of the pit will be back filled with soil. the nuts & bolts will be provided by the contractor as per nigams specification for which payment will be made at the prevailing store issue rates. the cost muffing and grouting will be paid extra. 75 lattice structure 76 erection of pcc poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractor as per nigams specification for which the payment will be made at the prevailing discom store issue rates. 77 in rural area 78 pcc poles 9 mtr. long(200kg.) 79 erection & assembly of 2 pole structures ofof steel supports or of pcc poles in excavated pit in alignment afterchecking the same with plumb line. including fixing of top bracing of m.s. channels with pilot plates and clamps. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractoras per nigams specfication for which the payment will be made at the prevailing discom store issue rates. 80 pcc poles 9 mtr. long(200kg.) 81 erection & fixing of g.i.stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.the work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension.size of stay set/stay wire 82 6x5/8 with 7/10 swg stay wire 83 providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.(1.2x1.2 x2.1 m)/tower 84 fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub station. 85 fixing of guarding bracket arms with clamp on erected support as per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 86 11 kv line 87 fixing of earth wire clamp on erected supportas per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 88 fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. the nuts &bolts are to be provided by the contractor as per nigams specification for which payment will be made as perprevailing discom store issue rates. 89 11 kv line 90 fixing and assembly of disc. point channel pair with pilot plates & clamps on erected single pole structure as per design. the nuts & bolts are to be provided by the contractor as per nigams specification for which payment will be made as per prevailingdiscom store issue rates. 91 11 kv line 92 fixing of 11kv b&s/t&c type disc insulator of 11kv lines(each unit consiting of 1nos.disc.& 1set of h/ w ) on terminal point including fixing of hardware and strips. 93 fixing of 11 kv pininsulator with pins. 94 ssembly and installation of horn gap fuse set (set of 3 nos)on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. the nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing discom store issue rates. 95 11kv horn gap fuse set. 96 installation testing as per nigams norm & commissioning of11/0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on hv&lv side, crimping of lugs/clamping earth connections of body and neutral of transformer with wire/strip (as already provided with earthing) complete in all respect. the pg clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing discom store issue rates. 97 10 & 16 kva 98 25 & 40 kva 99 fixing of danger plates on supports/structure 100 fixing of pg clamp of weasel /rabbit conductor 101 laying, jointing , stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire/p.g. clamps aluminium jointing sleeves will be used for jointing the conductor. the line must stand at proper voltage on charging. the contractor will be provide p.g. clamps for which payment will be made as per prevailing discom store issue rates. 102 acsr rabbit 103 laying, jointing,stringing,tensioning and clamping of g.i.earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.the nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing discom store issue rates. 104 (b) in rural area 105 g.i.earth wire 8 swg 106 drawing & strining of g.i 4 wire over the guarding brackets for guarding of road crossing /p&t crossing/railway track crossing (for one span only)with cross g.i wire laces at an intraval of two meter each or required as per location using eye bolt nuts. 107 8 swg with laces of 10 swg 108 earthing of line for all type of supports as per rec construction standards using stay wire/gi wire with one pcs of m.s. rod 20mm dia each 3 meter long and driving into earth by mechanical means ms rod, ms flat & stay wire will be supplied by the contractor. ifmaterial is supplied by the contractor the payment will be made as per prevailing discom store issue rates.(in case of pcc poles earthing mustbe connected with earthwire already available on pcc pole at bottom) 109 earthing of 11/0.4 kv distribution transformer /sub station with 3 pieces of m.s. rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. the work includes flattening of top ends of m.s. rod drilling a hole of 9/16 dia. at flattened top and tightening of m.s. flat 50x6mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with m.s. rod. top end hole. the flat will also be welded with m.s. rod. the end will be connected to equipments as under as under in sequence. 110 fixing of three phase meter cummeter box(complete unit)at the premises of existing/new consumerswith 4 nos anchor fastners with rust proof size m 6x50 mm on the wall as per the positionof holes already provided on the meter box. the meter box must be housed perfectly vertical/plumb line,anchor fasteners are to be supplied/provided by the contractor including safe carriage from s/d store to consumers site and depositing removed meter and meter box if any in s/d store). 111 in rural area 112 laying of 1100 volt heavy duty armoured xlpe cable of aluminum coudctor of following size conforming to is: 7098 (pt i) (latest amended) overhead service line from pole to meter terminals for release of new lt connections/replacement of damaged/obsolete service line (except agriculture one). the cable must be fixed on wall with clamps /hooks properly at a interval of one meter. 113 4 core 16/25 sq. mm 114 fixing of 3 phase lt shunt capacitor (3/6/9/12kvar) near starterof motor for agriculature consumers to be fixed with ms clamp of shape of size 2x10mm having two nos.holes for fixing of lt capacitors besides starter of consumer with the help of two no.machine screw. the starter shall be connected using pvc sheathed single core of 4 sq.mm ai. cable conforming to relevant is. the wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with ms compoundpvc tape roll. the ends of wire shall be properly crimped with lugsthimble etc.all material shall be supplied by the contractor except lt shunt capacitor (the lt shunt capacitor shall be supplied by nigam) ...

Jaipur Vidyut Vitran Nigam Limited - Rajasthan

32064846 supply, erection, installation and commissioning of material equipment for the work of release of ag connection in fy 2022 23 on turnkey basis in respect of bharatpur circle lot i under the domain of jaipur discom against tn 523 supply of material (all material shall be supplied as per specification enclosed with the bidding documents): 2 9 mtr. long pcc poles of 200 kg working load with factor of safty 2.5. 3 33 kv s/c lattice structure (36 ungalvanised with 1 nos 33 kv cross arm(channel) with required nuts and bolts. 4 11/0.433 kv, 40 kva aluminium wound bis level 2 completely self protected (csp) distribution transformers with provisio of lt bushing box 5 25 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 6 16 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 7 galvanised steel stay set 16x1800 mm 8 11 kv stay insulator 9 galvanised steel stay wire 7/10 swg 10 stay set clamps suitable for 9 mtr. long pcc poles 11 h/w for disc insulators 45kn t&c type 12 disc insulators 45kn t&c type 13 m.s. nuts & bolts (assorted size) 14 acsr rabbit conductor 15 11 kv v cross arm with top hamper and clamps ( angle) 16 galvanized m.s. froged 11 kv pin 17 11 kv pin insulator 18 11/0.4 kv s/s structure set for 3 ph 40/25/ 16 kva transformer on double pole 19 horn gap fuse set with post insulator 11 kv 20 ms rod type earthing set with wire & clamp with following details(1 no. galvanised m.s. rod 20 mm dia electrodes having3 meter length, 2 nos. galvanised earthing clamp of m.s.flat of size 50x6 mm 220 mm length. one welded with earthelectrode and loose to be bolted; 2 nos. galvanised bolts, nuts and spring washers and g.i.wire size 8 swg of 15 meter length) 21 1.4 mtr channel 100x50x6 mm bracket with clamp 22 4c x 16 sq. mm. lt pvc insulated pvc sheathed cable (armoured) 23 m.s. angles 75 x 75 x 6 mm (for guarding) 24 three phase four wire whole current meter of rating 10 60 a having backlit lcd display with meter box (free issue). 25 m.s. channel 75 x 40 x 6 mm (for extension bracket) 26 lt shunt capacotors 3 kvar 27 lt shunt capacotors 6 kvar 28 danger plate 29 11 kv line dp set 30 p.g. clamps for rabbit 31 g.s. earth wire 8 swg 32 erection of material: 33 trimming of tree branches/plants and preparing route approchases for proposed line. 34 excavation of pit in hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 35 (a) height of poles/r.s.joist/m.s. rail /size of pit 36 9 mtr/ 1.2mx0.6mx1.50 m deep 37 (b) lattice tower /size of pit 38 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 39 (c)stay set/depth of pit 40 6x5/8 0.75x0.5x1.35m 41 excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 42 (a) height of poles/r.s.joist/m.s. rail /size of pit 43 9 mtr/ 1.2mx0.6mx1.50 m deep 44 (b) lattice tower /size of pit 45 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 46 (c)stay set/depth of pit 47 6x5/8 0.75x0.5x1.35m 48 safe carriage of pcc poles including loading / un loading 49 c) 9 mtr.long 200 kg. pcc pole 50 within10 kms. 51 above 10 km. & upto 30 km. add foreach km. or part thereof 52 above 30 km. add for each km. or part thereof (50 km) 53 safe carriage of steel( fabricated and unfabricated) i.e.m.s. rails, r.s.joists, m.s.channels, m.s.angles, m.s.flat, g.i.stay sets, g.i. stay wire, g.i.wire nut & bolts etc. and acsr conductor including loading and unloading and stacking in nigam store /at work site 54 within10 kms. 55 above 10 kms. & upto 30 kms. add for each km.or part thereof. 56 above 30 kms. add for each kms. or partthereof. (50 km) 57 safe carriage of insulator, hardware, cable etc.including loading/unloading and stacking in nigam.stores etc. 58 within10 kms. 59 above 10 kms. & upto 30 kms. add for each km.or part thereof. 60 above 30 kms. add for each kms.or part thereof. (50 km) 61 safe carriage of fabricated lattice towers structures and sub station structures type ab, ab beams, isolators structures etc. including loading/unloading and stacking in the nigam. stores / at work site. 62 within10 kms. 63 above 10 kms. & upto 30 kms. add for each km.or part thereof. 64 above 30 kms. add for each kms.or part thereof.(50 km) 65 safe carriage of 11/.4 kv 3 phase distribution transformer including loading/unloading and stacking in nigam.stores etc. 66 10 &16 kva 67 within10 kms. 68 above 10 kms. & upto 30 kms. add for each km.or part thereof. 69 above 30 kms. add for each kms.or part thereof. (50 km) 70 25 & 40 kva 71 within10 kms. 72 above 10 kms. & upto 30 kms. add for each km.or part thereof. 73 above 30 kms. add for each kms.or part thereof. (50 km) 74 erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. the support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item no. 5.6 the remaining portion of the pit will be back filled with soil. the nuts & bolts will be provided by the contractor as per nigams specification for which payment will be made at the prevailing store issue rates. the cost muffing and grouting will be paid extra. 75 lattice structure 76 erection of pcc poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractor as per nigams specification for which the payment will be made at the prevailing discom store issue rates. 77 in rural area 78 pcc poles 9 mtr. long(200kg.) 79 erection & assembly of 2 pole structures ofof steel supports or of pcc poles in excavated pit in alignment afterchecking the same with plumb line. including fixing of top bracing of m.s. channels with pilot plates and clamps. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractoras per nigams specfication for which the payment will be made at the prevailing discom store issue rates. 80 pcc poles 9 mtr. long(200kg.) 81 erection & fixing of g.i.stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.the work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension.size of stay set/stay wire 82 6x5/8 with 7/10 swg stay wire 83 providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.(1.2x1.2 x2.1 m)/tower 84 fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub station. 85 fixing of guarding bracket arms with clamp on erected support as per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 86 11 kv line 87 fixing of earth wire clamp on erected supportas per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 88 fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. the nuts &bolts are to be provided by the contractor as per nigams specification for which payment will be made as perprevailing discom store issue rates. 89 11 kv line 90 fixing and assembly of disc. point channel pair with pilot plates & clamps on erected single pole structure as per design. the nuts & bolts are to be provided by the contractor as per nigams specification for which payment will be made as per prevailingdiscom store issue rates. 91 11 kv line 92 fixing of 11kv b&s/t&c type disc insulator of 11kv lines(each unit consiting of 1nos.disc.& 1set of h/ w ) on terminal point including fixing of hardware and strips. 93 fixing of 11 kv pininsulator with pins. 94 ssembly and installation of horn gap fuse set (set of 3 nos)on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. the nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing discom store issue rates. 95 11kv horn gap fuse set. 96 installation testing as per nigams norm & commissioning of11/0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on hv&lv side, crimping of lugs/clamping earth connections of body and neutral of transformer with wire/strip (as already provided with earthing) complete in all respect. the pg clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing discom store issue rates. 97 10 & 16 kva 98 25 & 40 kva 99 fixing of danger plates on supports/structure 100 fixing of pg clamp of weasel /rabbit conductor 101 laying, jointing , stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire/p.g. clamps aluminium jointing sleeves will be used for jointing the conductor. the line must stand at proper voltage on charging. the contractor will be provide p.g. clamps for which payment will be made as per prevailing discom store issue rates. 102 acsr rabbit 103 laying, jointing,stringing,tensioning and clamping of g.i.earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.the nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing discom store issue rates. 104 (b) in rural area 105 g.i.earth wire 8 swg 106 drawing & strining of g.i 4 wire over the guarding brackets for guarding of road crossing /p&t crossing/railway track crossing (for one span only)with cross g.i wire laces at an intraval of two meter each or required as per location using eye bolt nuts. 107 8 swg with laces of 10 swg 108 earthing of line for all type of supports as per rec construction standards using stay wire/gi wire with one pcs of m.s. rod 20mm dia each 3 meter long and driving into earth by mechanical means ms rod, ms flat & stay wire will be supplied by the contractor. ifmaterial is supplied by the contractor the payment will be made as per prevailing discom store issue rates.(in case of pcc poles earthing mustbe connected with earthwire already available on pcc pole at bottom) 109 earthing of 11/0.4 kv distribution transformer /sub station with 3 pieces of m.s. rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. the work includes flattening of top ends of m.s. rod drilling a hole of 9/16 dia. at flattened top and tightening of m.s. flat 50x6mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with m.s. rod. top end hole. the flat will also be welded with m.s. rod. the end will be connected to equipments as under as under in sequence. 110 fixing of three phase meter cummeter box(complete unit)at the premises of existing/new consumerswith 4 nos anchor fastners with rust proof size m 6x50 mm on the wall as per the positionof holes already provided on the meter box. the meter box must be housed perfectly vertical/plumb line,anchor fasteners are to be supplied/provided by the contractor including safe carriage from s/d store to consumers site and depositing removed meter and meter box if any in s/d store). 111 in rural area 112 laying of 1100 volt heavy duty armoured xlpe cable of aluminum coudctor of following size conforming to is: 7098 (pt i) (latest amended) overhead service line from pole to meter terminals for release of new lt connections/replacement of damaged/obsolete service line (except agriculture one). the cable must be fixed on wall with clamps /hooks properly at a interval of one meter. 113 4 core 16/25 sq. mm 114 fixing of 3 phase lt shunt capacitor (3/6/9/12kvar) near starterof motor for agriculature consumers to be fixed with ms clamp of shape of size 2x10mm having two nos.holes for fixing of lt capacitors besides starter of consumer with the help of two no.machine screw. the starter shall be connected using pvc sheathed single core of 4 sq.mm ai. cable conforming to relevant is. the wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with ms compoundpvc tape roll. the ends of wire shall be properly crimped with lugsthimble etc.all material shall be supplied by the contractor except lt shunt capacitor (the lt shunt capacitor shall be supplied by nigam) ...

Jaipur Vidyut Vitran Nigam Limited - Rajasthan

32064840 supply, erection, installation and commissioning of material equipment for the work of release of ag connection in fy 2022 23 on turnkey basis in respect of alwar circle lot iii under the domain of jaipur discom against tn 523 supply of material (all material shall be supplied as per specification enclosed with the bidding documents): 2 9 mtr. long pcc poles of 200 kg working load with factor of safty 2.5. 3 33 kv s/c lattice structure (36 ungalvanised with 1 nos 33 kv cross arm(channel) with required nuts and bolts. 4 11/0.433 kv, 40 kva aluminium wound bis level 2 completely self protected (csp) distribution transformers with provisio of lt bushing box 5 25 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 6 16 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 7 galvanised steel stay set 16x1800 mm 8 11 kv stay insulator 9 galvanised steel stay wire 7/10 swg 10 stay set clamps suitable for 9 mtr. long pcc poles 11 h/w for disc insulators 45kn t&c type 12 disc insulators 45kn t&c type 13 m.s. nuts & bolts (assorted size) 14 acsr rabbit conductor 15 11 kv v cross arm with top hamper and clamps ( angle) 16 galvanized m.s. froged 11 kv pin 17 11 kv pin insulator 18 11/0.4 kv s/s structure set for 3 ph 40/25/ 16 kva transformer on double pole 19 horn gap fuse set with post insulator 11 kv 20 ms rod type earthing set with wire & clamp with following details(1 no. galvanised m.s. rod 20 mm dia electrodes having3 meter length, 2 nos. galvanised earthing clamp of m.s.flat of size 50x6 mm 220 mm length. one welded with earthelectrode and loose to be bolted; 2 nos. galvanised bolts, nuts and spring washers and g.i.wire size 8 swg of 15 meter length) 21 1.4 mtr channel 100x50x6 mm bracket with clamp 22 4c x 16 sq. mm. lt pvc insulated pvc sheathed cable (armoured) 23 m.s. angles 75 x 75 x 6 mm (for guarding) 24 three phase four wire whole current meter of rating 10 60 a having backlit lcd display with meter box (free issue). 25 m.s. channel 75 x 40 x 6 mm (for extension bracket) 26 lt shunt capacotors 3 kvar 27 lt shunt capacotors 6 kvar 28 danger plate 29 11 kv line dp set 30 p.g. clamps for rabbit 31 g.s. earth wire 8 swg 32 erection of material: 33 trimming of tree branches/plants and preparing route approchases for proposed line. 34 excavation of pit in hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 35 (a) height of poles/r.s.joist/m.s. rail /size of pit 36 9 mtr/ 1.2mx0.6mx1.50 m deep 37 (b) lattice tower /size of pit 38 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 39 (c)stay set/depth of pit 40 6x5/8 0.75x0.5x1.35m 41 excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 42 (a) height of poles/r.s.joist/m.s. rail /size of pit 43 9 mtr/ 1.2mx0.6mx1.50 m deep 44 (b) lattice tower /size of pit 45 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 46 (c)stay set/depth of pit 47 6x5/8 0.75x0.5x1.35m 48 safe carriage of pcc poles including loading / un loading 49 c) 9 mtr.long 200 kg. pcc pole 50 within10 kms. 51 above 10 km. & upto 30 km. add foreach km. or part thereof 52 above 30 km. add for each km. or part thereof (50 km) 53 safe carriage of steel( fabricated and unfabricated) i.e.m.s. rails, r.s.joists, m.s.channels, m.s.angles, m.s.flat, g.i.stay sets, g.i. stay wire, g.i.wire nut & bolts etc. and acsr conductor including loading and unloading and stacking in nigam store /at work site 54 within10 kms. 55 above 10 kms. & upto 30 kms. add for each km.or part thereof. 56 above 30 kms. add for each kms. or partthereof. (50 km) 57 safe carriage of insulator, hardware, cable etc.including loading/unloading and stacking in nigam.stores etc. 58 within10 kms. 59 above 10 kms. & upto 30 kms. add for each km.or part thereof. 60 above 30 kms. add for each kms.or part thereof. (50 km) 61 safe carriage of fabricated lattice towers structures and sub station structures type ab, ab beams, isolators structures etc. including loading/unloading and stacking in the nigam. stores / at work site. 62 within10 kms. 63 above 10 kms. & upto 30 kms. add for each km.or part thereof. 64 above 30 kms. add for each kms.or part thereof.(50 km) 65 safe carriage of 11/.4 kv 3 phase distribution transformer including loading/unloading and stacking in nigam.stores etc. 66 10 &16 kva 67 within10 kms. 68 above 10 kms. & upto 30 kms. add for each km.or part thereof. 69 above 30 kms. add for each kms.or part thereof. (50 km) 70 25 & 40 kva 71 within10 kms. 72 above 10 kms. & upto 30 kms. add for each km.or part thereof. 73 above 30 kms. add for each kms.or part thereof. (50 km) 74 erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. the support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item no. 5.6 the remaining portion of the pit will be back filled with soil. the nuts & bolts will be provided by the contractor as per nigams specification for which payment will be made at the prevailing store issue rates. the cost muffing and grouting will be paid extra. 75 lattice structure 76 erection of pcc poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractor as per nigams specification for which the payment will be made at the prevailing discom store issue rates. 77 in rural area 78 pcc poles 9 mtr. long(200kg.) 79 erection & assembly of 2 pole structures ofof steel supports or of pcc poles in excavated pit in alignment afterchecking the same with plumb line. including fixing of top bracing of m.s. channels with pilot plates and clamps. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractoras per nigams specfication for which the payment will be made at the prevailing discom store issue rates. 80 pcc poles 9 mtr. long(200kg.) 81 erection & fixing of g.i.stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.the work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension.size of stay set/stay wire 82 6x5/8 with 7/10 swg stay wire 83 providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.(1.2x1.2 x2.1 m)/tower 84 fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub station. 85 fixing of guarding bracket arms with clamp on erected support as per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 86 11 kv line 87 fixing of earth wire clamp on erected supportas per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 88 fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. the nuts &bolts are to be provided by the contractor as per nigams specification for which payment will be made as perprevailing discom store issue rates. 89 11 kv line 90 fixing and assembly of disc. point channel pair with pilot plates & clamps on erected single pole structure as per design. the nuts & bolts are to be provided by the contractor as per nigams specification for which payment will be made as per prevailingdiscom store issue rates. 91 11 kv line 92 fixing of 11kv b&s/t&c type disc insulator of 11kv lines(each unit consiting of 1nos.disc.& 1set of h/ w ) on terminal point including fixing of hardware and strips. 93 fixing of 11 kv pininsulator with pins. 94 ssembly and installation of horn gap fuse set (set of 3 nos)on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. the nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing discom store issue rates. 95 11kv horn gap fuse set. 96 installation testing as per nigams norm & commissioning of11/0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on hv&lv side, crimping of lugs/clamping earth connections of body and neutral of transformer with wire/strip (as already provided with earthing) complete in all respect. the pg clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing discom store issue rates. 97 10 & 16 kva 98 25 & 40 kva 99 fixing of danger plates on supports/structure 100 fixing of pg clamp of weasel /rabbit conductor 101 laying, jointing , stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire/p.g. clamps aluminium jointing sleeves will be used for jointing the conductor. the line must stand at proper voltage on charging. the contractor will be provide p.g. clamps for which payment will be made as per prevailing discom store issue rates. 102 acsr rabbit 103 laying, jointing,stringing,tensioning and clamping of g.i.earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.the nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing discom store issue rates. 104 (b) in rural area 105 g.i.earth wire 8 swg 106 drawing & strining of g.i 4 wire over the guarding brackets for guarding of road crossing /p&t crossing/railway track crossing (for one span only)with cross g.i wire laces at an intraval of two meter each or required as per location using eye bolt nuts. 107 8 swg with laces of 10 swg 108 earthing of line for all type of supports as per rec construction standards using stay wire/gi wire with one pcs of m.s. rod 20mm dia each 3 meter long and driving into earth by mechanical means ms rod, ms flat & stay wire will be supplied by the contractor. ifmaterial is supplied by the contractor the payment will be made as per prevailing discom store issue rates.(in case of pcc poles earthing mustbe connected with earthwire already available on pcc pole at bottom) 109 earthing of 11/0.4 kv distribution transformer /sub station with 3 pieces of m.s. rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. the work includes flattening of top ends of m.s. rod drilling a hole of 9/16 dia. at flattened top and tightening of m.s. flat 50x6mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with m.s. rod. top end hole. the flat will also be welded with m.s. rod. the end will be connected to equipments as under as under in sequence. 110 fixing of three phase meter cummeter box(complete unit)at the premises of existing/new consumerswith 4 nos anchor fastners with rust proof size m 6x50 mm on the wall as per the positionof holes already provided on the meter box. the meter box must be housed perfectly vertical/plumb line,anchor fasteners are to be supplied/provided by the contractor including safe carriage from s/d store to consumers site and depositing removed meter and meter box if any in s/d store). 111 in rural area 112 laying of 1100 volt heavy duty armoured xlpe cable of aluminum coudctor of following size conforming to is: 7098 (pt i) (latest amended) overhead service line from pole to meter terminals for release of new lt connections/replacement of damaged/obsolete service line (except agriculture one). the cable must be fixed on wall with clamps /hooks properly at a interval of one meter. 113 4 core 16/25 sq. mm 114 fixing of 3 phase lt shunt capacitor (3/6/9/12kvar) near starterof motor for agriculature consumers to be fixed with ms clamp of shape of size 2x10mm having two nos.holes for fixing of lt capacitors besides starter of consumer with the help of two no.machine screw. the starter shall be connected using pvc sheathed single core of 4 sq.mm ai. cable conforming to relevant is. the wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with ms compoundpvc tape roll. the ends of wire shall be properly crimped with lugsthimble etc.all material shall be supplied by the contractor except lt shunt capacitor (the lt shunt capacitor shall be supplied by nigam) ...

Jaipur Vidyut Vitran Nigam Limited - Rajasthan

32064838 supply, erection, installation and commissioning of material equipment for the work of release of ag connection in fy 2022 23 on turnkey basis in respect of jhalawar circle lot i under the domain of jaipur discom against tn 523 supply of material (all material shall be supplied as per specification enclosed with the bidding documents): 2 9 mtr. long pcc poles of 200 kg working load with factor of safty 2.5. 3 33 kv s/c lattice structure (36 ungalvanised with 1 nos 33 kv cross arm(channel) with required nuts and bolts. 4 11/0.433 kv, 40 kva aluminium wound bis level 2 completely self protected (csp) distribution transformers with provisio of lt bushing box 5 25 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 6 16 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 7 galvanised steel stay set 16x1800 mm 8 11 kv stay insulator 9 galvanised steel stay wire 7/10 swg 10 stay set clamps suitable for 9 mtr. long pcc poles 11 h/w for disc insulators 45kn t&c type 12 disc insulators 45kn t&c type 13 m.s. nuts & bolts (assorted size) 14 acsr rabbit conductor 15 11 kv v cross arm with top hamper and clamps ( angle) 16 galvanized m.s. froged 11 kv pin 17 11 kv pin insulator 18 11/0.4 kv s/s structure set for 3 ph 40/25/ 16 kva transformer on double pole 19 horn gap fuse set with post insulator 11 kv 20 ms rod type earthing set with wire & clamp with following details(1 no. galvanised m.s. rod 20 mm dia electrodes having3 meter length, 2 nos. galvanised earthing clamp of m.s.flat of size 50x6 mm 220 mm length. one welded with earthelectrode and loose to be bolted; 2 nos. galvanised bolts, nuts and spring washers and g.i.wire size 8 swg of 15 meter length) 21 1.4 mtr channel 100x50x6 mm bracket with clamp 22 4c x 16 sq. mm. lt pvc insulated pvc sheathed cable (armoured) 23 m.s. angles 75 x 75 x 6 mm (for guarding) 24 three phase four wire whole current meter of rating 10 60 a having backlit lcd display with meter box (free issue). 25 m.s. channel 75 x 40 x 6 mm (for extension bracket) 26 lt shunt capacotors 3 kvar 27 lt shunt capacotors 6 kvar 28 danger plate 29 11 kv line dp set 30 p.g. clamps for rabbit 31 g.s. earth wire 8 swg 32 erection of material: 33 trimming of tree branches/plants and preparing route approchases for proposed line. 34 excavation of pit in hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 35 (a) height of poles/r.s.joist/m.s. rail /size of pit 36 9 mtr/ 1.2mx0.6mx1.50 m deep 37 (b) lattice tower /size of pit 38 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 39 (c)stay set/depth of pit 40 6x5/8 0.75x0.5x1.35m 41 excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 42 (a) height of poles/r.s.joist/m.s. rail /size of pit 43 9 mtr/ 1.2mx0.6mx1.50 m deep 44 (b) lattice tower /size of pit 45 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 46 (c)stay set/depth of pit 47 6x5/8 0.75x0.5x1.35m 48 safe carriage of pcc poles including loading / un loading 49 c) 9 mtr.long 200 kg. pcc pole 50 within10 kms. 51 above 10 km. & upto 30 km. add foreach km. or part thereof 52 above 30 km. add for each km. or part thereof (50 km) 53 safe carriage of steel( fabricated and unfabricated) i.e.m.s. rails, r.s.joists, m.s.channels, m.s.angles, m.s.flat, g.i.stay sets, g.i. stay wire, g.i.wire nut & bolts etc. and acsr conductor including loading and unloading and stacking in nigam store /at work site 54 within10 kms. 55 above 10 kms. & upto 30 kms. add for each km.or part thereof. 56 above 30 kms. add for each kms. or partthereof. (50 km) 57 safe carriage of insulator, hardware, cable etc.including loading/unloading and stacking in nigam.stores etc. 58 within10 kms. 59 above 10 kms. & upto 30 kms. add for each km.or part thereof. 60 above 30 kms. add for each kms.or part thereof. (50 km) 61 safe carriage of fabricated lattice towers structures and sub station structures type ab, ab beams, isolators structures etc. including loading/unloading and stacking in the nigam. stores / at work site. 62 within10 kms. 63 above 10 kms. & upto 30 kms. add for each km.or part thereof. 64 above 30 kms. add for each kms.or part thereof.(50 km) 65 safe carriage of 11/.4 kv 3 phase distribution transformer including loading/unloading and stacking in nigam.stores etc. 66 10 &16 kva 67 within10 kms. 68 above 10 kms. & upto 30 kms. add for each km.or part thereof. 69 above 30 kms. add for each kms.or part thereof. (50 km) 70 25 & 40 kva 71 within10 kms. 72 above 10 kms. & upto 30 kms. add for each km.or part thereof. 73 above 30 kms. add for each kms.or part thereof. (50 km) 74 erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. the support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item no. 5.6 the remaining portion of the pit will be back filled with soil. the nuts & bolts will be provided by the contractor as per nigams specification for which payment will be made at the prevailing store issue rates. the cost muffing and grouting will be paid extra. 75 lattice structure 76 erection of pcc poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractor as per nigams specification for which the payment will be made at the prevailing discom store issue rates. 77 in rural area 78 pcc poles 9 mtr. long(200kg.) 79 erection & assembly of 2 pole structures ofof steel supports or of pcc poles in excavated pit in alignment afterchecking the same with plumb line. including fixing of top bracing of m.s. channels with pilot plates and clamps. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractoras per nigams specfication for which the payment will be made at the prevailing discom store issue rates. 80 pcc poles 9 mtr. long(200kg.) 81 erection & fixing of g.i.stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.the work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension.size of stay set/stay wire 82 6x5/8 with 7/10 swg stay wire 83 providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.(1.2x1.2 x2.1 m)/tower 84 fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub station. 85 fixing of guarding bracket arms with clamp on erected support as per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 86 11 kv line 87 fixing of earth wire clamp on erected supportas per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 88 fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. the nuts &bolts are to be provided by the contractor as per nigams specification for which payment will be made as perprevailing discom store issue rates. 89 11 kv line 90 fixing and assembly of disc. point channel pair with pilot plates & clamps on erected single pole structure as per design. the nuts & bolts are to be provided by the contractor as per nigams specification for which payment will be made as per prevailingdiscom store issue rates. 91 11 kv line 92 fixing of 11kv b&s/t&c type disc insulator of 11kv lines(each unit consiting of 1nos.disc.& 1set of h/ w ) on terminal point including fixing of hardware and strips. 93 fixing of 11 kv pininsulator with pins. 94 ssembly and installation of horn gap fuse set (set of 3 nos)on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. the nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing discom store issue rates. 95 11kv horn gap fuse set. 96 installation testing as per nigams norm & commissioning of11/0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on hv&lv side, crimping of lugs/clamping earth connections of body and neutral of transformer with wire/strip (as already provided with earthing) complete in all respect. the pg clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing discom store issue rates. 97 10 & 16 kva 98 25 & 40 kva 99 fixing of danger plates on supports/structure 100 fixing of pg clamp of weasel /rabbit conductor 101 laying, jointing , stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire/p.g. clamps aluminium jointing sleeves will be used for jointing the conductor. the line must stand at proper voltage on charging. the contractor will be provide p.g. clamps for which payment will be made as per prevailing discom store issue rates. 102 acsr rabbit 103 laying, jointing,stringing,tensioning and clamping of g.i.earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.the nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing discom store issue rates. 104 (b) in rural area 105 g.i.earth wire 8 swg 106 drawing & strining of g.i 4 wire over the guarding brackets for guarding of road crossing /p&t crossing/railway track crossing (for one span only)with cross g.i wire laces at an intraval of two meter each or required as per location using eye bolt nuts. 107 8 swg with laces of 10 swg 108 earthing of line for all type of supports as per rec construction standards using stay wire/gi wire with one pcs of m.s. rod 20mm dia each 3 meter long and driving into earth by mechanical means ms rod, ms flat & stay wire will be supplied by the contractor. ifmaterial is supplied by the contractor the payment will be made as per prevailing discom store issue rates.(in case of pcc poles earthing mustbe connected with earthwire already available on pcc pole at bottom) 109 earthing of 11/0.4 kv distribution transformer /sub station with 3 pieces of m.s. rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. the work includes flattening of top ends of m.s. rod drilling a hole of 9/16 dia. at flattened top and tightening of m.s. flat 50x6mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with m.s. rod. top end hole. the flat will also be welded with m.s. rod. the end will be connected to equipments as under as under in sequence. 110 fixing of three phase meter cummeter box(complete unit)at the premises of existing/new consumerswith 4 nos anchor fastners with rust proof size m 6x50 mm on the wall as per the positionof holes already provided on the meter box. the meter box must be housed perfectly vertical/plumb line,anchor fasteners are to be supplied/provided by the contractor including safe carriage from s/d store to consumers site and depositing removed meter and meter box if any in s/d store). 111 in rural area 112 laying of 1100 volt heavy duty armoured xlpe cable of aluminum coudctor of following size conforming to is: 7098 (pt i) (latest amended) overhead service line from pole to meter terminals for release of new lt connections/replacement of damaged/obsolete service line (except agriculture one). the cable must be fixed on wall with clamps /hooks properly at a interval of one meter. 113 4 core 16/25 sq. mm 114 fixing of 3 phase lt shunt capacitor (3/6/9/12kvar) near starterof motor for agriculature consumers to be fixed with ms clamp of shape of size 2x10mm having two nos.holes for fixing of lt capacitors besides starter of consumer with the help of two no.machine screw. the starter shall be connected using pvc sheathed single core of 4 sq.mm ai. cable conforming to relevant is. the wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with ms compoundpvc tape roll. the ends of wire shall be properly crimped with lugsthimble etc.all material shall be supplied by the contractor except lt shunt capacitor (the lt shunt capacitor shall be supplied by nigam) ...

Jaipur Vidyut Vitran Nigam Limited - Rajasthan

32064834 supply, erection, installation and commissioning of material equipment for the work of release of ag connection in fy 2022 23 on turnkey basis in respect of bundi circle lot ii under the domain of jaipur discom against tn 52 supply of material (all material shall be supplied as per specification enclosed with the bidding documents): 2 9 mtr. long pcc poles of 200 kg working load with factor of safty 2.5. 3 33 kv s/c lattice structure (36 ungalvanised with 1 nos 33 kv cross arm(channel) with required nuts and bolts. 4 11/0.433 kv, 40 kva aluminium wound bis level 2 completely self protected (csp) distribution transformers with provisio of lt bushing box 5 25 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 6 16 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 7 galvanised steel stay set 16x1800 mm 8 11 kv stay insulator 9 galvanised steel stay wire 7/10 swg 10 stay set clamps suitable for 9 mtr. long pcc poles 11 h/w for disc insulators 45kn t&c type 12 disc insulators 45kn t&c type 13 m.s. nuts & bolts (assorted size) 14 acsr rabbit conductor 15 11 kv v cross arm with top hamper and clamps ( angle) 16 galvanized m.s. froged 11 kv pin 17 11 kv pin insulator 18 11/0.4 kv s/s structure set for 3 ph 40/25/ 16 kva transformer on double pole 19 horn gap fuse set with post insulator 11 kv 20 ms rod type earthing set with wire & clamp with following details(1 no. galvanised m.s. rod 20 mm dia electrodes having3 meter length, 2 nos. galvanised earthing clamp of m.s.flat of size 50x6 mm 220 mm length. one welded with earthelectrode and loose to be bolted; 2 nos. galvanised bolts, nuts and spring washers and g.i.wire size 8 swg of 15 meter length) 21 1.4 mtr channel 100x50x6 mm bracket with clamp 22 4c x 16 sq. mm. lt pvc insulated pvc sheathed cable (armoured) 23 m.s. angles 75 x 75 x 6 mm (for guarding) 24 three phase four wire whole current meter of rating 10 60 a having backlit lcd display with meter box (free issue). 25 m.s. channel 75 x 40 x 6 mm (for extension bracket) 26 lt shunt capacotors 3 kvar 27 lt shunt capacotors 6 kvar 28 danger plate 29 11 kv line dp set 30 p.g. clamps for rabbit 31 g.s. earth wire 8 swg 32 erection of material: 33 trimming of tree branches/plants and preparing route approchases for proposed line. 34 excavation of pit in hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 35 (a) height of poles/r.s.joist/m.s. rail /size of pit 36 9 mtr/ 1.2mx0.6mx1.50 m deep 37 (b) lattice tower /size of pit 38 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 39 (c)stay set/depth of pit 40 6x5/8 0.75x0.5x1.35m 41 excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 42 (a) height of poles/r.s.joist/m.s. rail /size of pit 43 9 mtr/ 1.2mx0.6mx1.50 m deep 44 (b) lattice tower /size of pit 45 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 46 (c)stay set/depth of pit 47 6x5/8 0.75x0.5x1.35m 48 safe carriage of pcc poles including loading / un loading 49 c) 9 mtr.long 200 kg. pcc pole 50 within10 kms. 51 above 10 km. & upto 30 km. add foreach km. or part thereof 52 above 30 km. add for each km. or part thereof (50 km) 53 safe carriage of steel( fabricated and unfabricated) i.e.m.s. rails, r.s.joists, m.s.channels, m.s.angles, m.s.flat, g.i.stay sets, g.i. stay wire, g.i.wire nut & bolts etc. and acsr conductor including loading and unloading and stacking in nigam store /at work site 54 within10 kms. 55 above 10 kms. & upto 30 kms. add for each km.or part thereof. 56 above 30 kms. add for each kms. or partthereof. (50 km) 57 safe carriage of insulator, hardware, cable etc.including loading/unloading and stacking in nigam.stores etc. 58 within10 kms. 59 above 10 kms. & upto 30 kms. add for each km.or part thereof. 60 above 30 kms. add for each kms.or part thereof. (50 km) 61 safe carriage of fabricated lattice towers structures and sub station structures type ab, ab beams, isolators structures etc. including loading/unloading and stacking in the nigam. stores / at work site. 62 within10 kms. 63 above 10 kms. & upto 30 kms. add for each km.or part thereof. 64 above 30 kms. add for each kms.or part thereof.(50 km) 65 safe carriage of 11/.4 kv 3 phase distribution transformer including loading/unloading and stacking in nigam.stores etc. 66 10 &16 kva 67 within10 kms. 68 above 10 kms. & upto 30 kms. add for each km.or part thereof. 69 above 30 kms. add for each kms.or part thereof. (50 km) 70 25 & 40 kva 71 within10 kms. 72 above 10 kms. & upto 30 kms. add for each km.or part thereof. 73 above 30 kms. add for each kms.or part thereof. (50 km) 74 erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. the support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item no. 5.6 the remaining portion of the pit will be back filled with soil. the nuts & bolts will be provided by the contractor as per nigams specification for which payment will be made at the prevailing store issue rates. the cost muffing and grouting will be paid extra. 75 lattice structure 76 erection of pcc poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractor as per nigams specification for which the payment will be made at the prevailing discom store issue rates. 77 in rural area 78 pcc poles 9 mtr. long(200kg.) 79 erection & assembly of 2 pole structures ofof steel supports or of pcc poles in excavated pit in alignment afterchecking the same with plumb line. including fixing of top bracing of m.s. channels with pilot plates and clamps. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractoras per nigams specfication for which the payment will be made at the prevailing discom store issue rates. 80 pcc poles 9 mtr. long(200kg.) 81 erection & fixing of g.i.stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.the work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension.size of stay set/stay wire 82 6x5/8 with 7/10 swg stay wire 83 providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.(1.2x1.2 x2.1 m)/tower 84 fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub station. 85 fixing of guarding bracket arms with clamp on erected support as per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 86 11 kv line 87 fixing of earth wire clamp on erected supportas per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 88 fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. the nuts &bolts are to be provided by the contractor as per nigams specification for which payment will be made as perprevailing discom store issue rates. 89 11 kv line 90 fixing and assembly of disc. point channel pair with pilot plates & clamps on erected single pole structure as per design. the nuts & bolts are to be provided by the contractor as per nigams specification for which payment will be made as per prevailingdiscom store issue rates. 91 11 kv line 92 fixing of 11kv b&s/t&c type disc insulator of 11kv lines(each unit consiting of 1nos.disc.& 1set of h/ w ) on terminal point including fixing of hardware and strips. 93 fixing of 11 kv pininsulator with pins. 94 ssembly and installation of horn gap fuse set (set of 3 nos)on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. the nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing discom store issue rates. 95 11kv horn gap fuse set. 96 installation testing as per nigams norm & commissioning of11/0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on hv&lv side, crimping of lugs/clamping earth connections of body and neutral of transformer with wire/strip (as already provided with earthing) complete in all respect. the pg clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing discom store issue rates. 97 10 & 16 kva 98 25 & 40 kva 99 fixing of danger plates on supports/structure 100 fixing of pg clamp of weasel /rabbit conductor 101 laying, jointing , stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire/p.g. clamps aluminium jointing sleeves will be used for jointing the conductor. the line must stand at proper voltage on charging. the contractor will be provide p.g. clamps for which payment will be made as per prevailing discom store issue rates. 102 acsr rabbit 103 laying, jointing,stringing,tensioning and clamping of g.i.earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.the nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing discom store issue rates. 104 (b) in rural area 105 g.i.earth wire 8 swg 106 drawing & strining of g.i 4 wire over the guarding brackets for guarding of road crossing /p&t crossing/railway track crossing (for one span only)with cross g.i wire laces at an intraval of two meter each or required as per location using eye bolt nuts. 107 8 swg with laces of 10 swg 108 earthing of line for all type of supports as per rec construction standards using stay wire/gi wire with one pcs of m.s. rod 20mm dia each 3 meter long and driving into earth by mechanical means ms rod, ms flat & stay wire will be supplied by the contractor. ifmaterial is supplied by the contractor the payment will be made as per prevailing discom store issue rates.(in case of pcc poles earthing mustbe connected with earthwire already available on pcc pole at bottom) 109 earthing of 11/0.4 kv distribution transformer /sub station with 3 pieces of m.s. rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. the work includes flattening of top ends of m.s. rod drilling a hole of 9/16 dia. at flattened top and tightening of m.s. flat 50x6mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with m.s. rod. top end hole. the flat will also be welded with m.s. rod. the end will be connected to equipments as under as under in sequence. 110 fixing of three phase meter cummeter box(complete unit)at the premises of existing/new consumerswith 4 nos anchor fastners with rust proof size m 6x50 mm on the wall as per the positionof holes already provided on the meter box. the meter box must be housed perfectly vertical/plumb line,anchor fasteners are to be supplied/provided by the contractor including safe carriage from s/d store to consumers site and depositing removed meter and meter box if any in s/d store). 111 in rural area 112 laying of 1100 volt heavy duty armoured xlpe cable of aluminum coudctor of following size conforming to is: 7098 (pt i) (latest amended) overhead service line from pole to meter terminals for release of new lt connections/replacement of damaged/obsolete service line (except agriculture one). the cable must be fixed on wall with clamps /hooks properly at a interval of one meter. 113 4 core 16/25 sq. mm 114 fixing of 3 phase lt shunt capacitor (3/6/9/12kvar) near starterof motor for agriculature consumers to be fixed with ms clamp of shape of size 2x10mm having two nos.holes for fixing of lt capacitors besides starter of consumer with the help of two no.machine screw. the starter shall be connected using pvc sheathed single core of 4 sq.mm ai. cable conforming to relevant is. the wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with ms compoundpvc tape roll. the ends of wire shall be properly crimped with lugsthimble etc.all material shall be supplied by the contractor except lt shunt capacitor (the lt shunt capacitor shall be supplied by nigam) ...

Jaipur Vidyut Vitran Nigam Limited - Rajasthan

32064830 supply, erection, installation and commissioning of material equipment for the work of release of ag connection in fy 2022 23 on turnkey basis in respect of sawai madhopur circle lot i under the domain of jaipur discom against tn supply of material (all material shall be supplied as per specification enclosed with the bidding documents): 2 9 mtr. long pcc poles of 200 kg working load with factor of safty 2.5. 3 33 kv s/c lattice structure (36 ungalvanised with 1 nos 33 kv cross arm(channel) with required nuts and bolts. 4 11/0.433 kv, 40 kva aluminium wound bis level 2 completely self protected (csp) distribution transformers with provisio of lt bushing box 5 25 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 6 16 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 7 galvanised steel stay set 16x1800 mm 8 11 kv stay insulator 9 galvanised steel stay wire 7/10 swg 10 stay set clamps suitable for 9 mtr. long pcc poles 11 h/w for disc insulators 45kn t&c type 12 disc insulators 45kn t&c type 13 m.s. nuts & bolts (assorted size) 14 acsr rabbit conductor 15 11 kv v cross arm with top hamper and clamps ( angle) 16 galvanized m.s. froged 11 kv pin 17 11 kv pin insulator 18 11/0.4 kv s/s structure set for 3 ph 40/25/ 16 kva transformer on double pole 19 horn gap fuse set with post insulator 11 kv 20 ms rod type earthing set with wire & clamp with following details(1 no. galvanised m.s. rod 20 mm dia electrodes having3 meter length, 2 nos. galvanised earthing clamp of m.s.flat of size 50x6 mm 220 mm length. one welded with earthelectrode and loose to be bolted; 2 nos. galvanised bolts, nuts and spring washers and g.i.wire size 8 swg of 15 meter length) 21 1.4 mtr channel 100x50x6 mm bracket with clamp 22 4c x 16 sq. mm. lt pvc insulated pvc sheathed cable (armoured) 23 m.s. angles 75 x 75 x 6 mm (for guarding) 24 three phase four wire whole current meter of rating 10 60 a having backlit lcd display with meter box (free issue). 25 m.s. channel 75 x 40 x 6 mm (for extension bracket) 26 lt shunt capacotors 3 kvar 27 lt shunt capacotors 6 kvar 28 danger plate 29 11 kv line dp set 30 p.g. clamps for rabbit 31 g.s. earth wire 8 swg 32 erection of material: 33 trimming of tree branches/plants and preparing route approchases for proposed line. 34 excavation of pit in hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 35 (a) height of poles/r.s.joist/m.s. rail /size of pit 36 9 mtr/ 1.2mx0.6mx1.50 m deep 37 (b) lattice tower /size of pit 38 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 39 (c)stay set/depth of pit 40 6x5/8 0.75x0.5x1.35m 41 excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 42 (a) height of poles/r.s.joist/m.s. rail /size of pit 43 9 mtr/ 1.2mx0.6mx1.50 m deep 44 (b) lattice tower /size of pit 45 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 46 (c)stay set/depth of pit 47 6x5/8 0.75x0.5x1.35m 48 safe carriage of pcc poles including loading / un loading 49 c) 9 mtr.long 200 kg. pcc pole 50 within10 kms. 51 above 10 km. & upto 30 km. add foreach km. or part thereof 52 above 30 km. add for each km. or part thereof (50 km) 53 safe carriage of steel( fabricated and unfabricated) i.e.m.s. rails, r.s.joists, m.s.channels, m.s.angles, m.s.flat, g.i.stay sets, g.i. stay wire, g.i.wire nut & bolts etc. and acsr conductor including loading and unloading and stacking in nigam store /at work site 54 within10 kms. 55 above 10 kms. & upto 30 kms. add for each km.or part thereof. 56 above 30 kms. add for each kms. or partthereof. (50 km) 57 safe carriage of insulator, hardware, cable etc.including loading/unloading and stacking in nigam.stores etc. 58 within10 kms. 59 above 10 kms. & upto 30 kms. add for each km.or part thereof. 60 above 30 kms. add for each kms.or part thereof. (50 km) 61 safe carriage of fabricated lattice towers structures and sub station structures type ab, ab beams, isolators structures etc. including loading/unloading and stacking in the nigam. stores / at work site. 62 within10 kms. 63 above 10 kms. & upto 30 kms. add for each km.or part thereof. 64 above 30 kms. add for each kms.or part thereof.(50 km) 65 safe carriage of 11/.4 kv 3 phase distribution transformer including loading/unloading and stacking in nigam.stores etc. 66 10 &16 kva 67 within10 kms. 68 above 10 kms. & upto 30 kms. add for each km.or part thereof. 69 above 30 kms. add for each kms.or part thereof. (50 km) 70 25 & 40 kva 71 within10 kms. 72 above 10 kms. & upto 30 kms. add for each km.or part thereof. 73 above 30 kms. add for each kms.or part thereof. (50 km) 74 erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. the support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item no. 5.6 the remaining portion of the pit will be back filled with soil. the nuts & bolts will be provided by the contractor as per nigams specification for which payment will be made at the prevailing store issue rates. the cost muffing and grouting will be paid extra. 75 lattice structure 76 erection of pcc poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractor as per nigams specification for which the payment will be made at the prevailing discom store issue rates. 77 in rural area 78 pcc poles 9 mtr. long(200kg.) 79 erection & assembly of 2 pole structures ofof steel supports or of pcc poles in excavated pit in alignment afterchecking the same with plumb line. including fixing of top bracing of m.s. channels with pilot plates and clamps. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractoras per nigams specfication for which the payment will be made at the prevailing discom store issue rates. 80 pcc poles 9 mtr. long(200kg.) 81 erection & fixing of g.i.stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.the work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension.size of stay set/stay wire 82 6x5/8 with 7/10 swg stay wire 83 providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.(1.2x1.2 x2.1 m)/tower 84 fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub station. 85 fixing of guarding bracket arms with clamp on erected support as per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 86 11 kv line 87 fixing of earth wire clamp on erected supportas per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 88 fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. the nuts &bolts are to be provided by the contractor as per nigams specification for which payment will be made as perprevailing discom store issue rates. 89 11 kv line 90 fixing and assembly of disc. point channel pair with pilot plates & clamps on erected single pole structure as per design. the nuts & bolts are to be provided by the contractor as per nigams specification for which payment will be made as per prevailingdiscom store issue rates. 91 11 kv line 92 fixing of 11kv b&s/t&c type disc insulator of 11kv lines(each unit consiting of 1nos.disc.& 1set of h/ w ) on terminal point including fixing of hardware and strips. 93 fixing of 11 kv pininsulator with pins. 94 ssembly and installation of horn gap fuse set (set of 3 nos)on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. the nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing discom store issue rates. 95 11kv horn gap fuse set. 96 installation testing as per nigams norm & commissioning of11/0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on hv&lv side, crimping of lugs/clamping earth connections of body and neutral of transformer with wire/strip (as already provided with earthing) complete in all respect. the pg clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing discom store issue rates. 97 10 & 16 kva 98 25 & 40 kva 99 fixing of danger plates on supports/structure 100 fixing of pg clamp of weasel /rabbit conductor 101 laying, jointing , stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire/p.g. clamps aluminium jointing sleeves will be used for jointing the conductor. the line must stand at proper voltage on charging. the contractor will be provide p.g. clamps for which payment will be made as per prevailing discom store issue rates. 102 acsr rabbit 103 laying, jointing,stringing,tensioning and clamping of g.i.earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.the nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing discom store issue rates. 104 (b) in rural area 105 g.i.earth wire 8 swg 106 drawing & strining of g.i 4 wire over the guarding brackets for guarding of road crossing /p&t crossing/railway track crossing (for one span only)with cross g.i wire laces at an intraval of two meter each or required as per location using eye bolt nuts. 107 8 swg with laces of 10 swg 108 earthing of line for all type of supports as per rec construction standards using stay wire/gi wire with one pcs of m.s. rod 20mm dia each 3 meter long and driving into earth by mechanical means ms rod, ms flat & stay wire will be supplied by the contractor. ifmaterial is supplied by the contractor the payment will be made as per prevailing discom store issue rates.(in case of pcc poles earthing mustbe connected with earthwire already available on pcc pole at bottom) 109 earthing of 11/0.4 kv distribution transformer /sub station with 3 pieces of m.s. rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. the work includes flattening of top ends of m.s. rod drilling a hole of 9/16 dia. at flattened top and tightening of m.s. flat 50x6mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with m.s. rod. top end hole. the flat will also be welded with m.s. rod. the end will be connected to equipments as under as under in sequence. 110 fixing of three phase meter cummeter box(complete unit)at the premises of existing/new consumerswith 4 nos anchor fastners with rust proof size m 6x50 mm on the wall as per the positionof holes already provided on the meter box. the meter box must be housed perfectly vertical/plumb line,anchor fasteners are to be supplied/provided by the contractor including safe carriage from s/d store to consumers site and depositing removed meter and meter box if any in s/d store). 111 in rural area 112 laying of 1100 volt heavy duty armoured xlpe cable of aluminum coudctor of following size conforming to is: 7098 (pt i) (latest amended) overhead service line from pole to meter terminals for release of new lt connections/replacement of damaged/obsolete service line (except agriculture one). the cable must be fixed on wall with clamps /hooks properly at a interval of one meter. 113 4 core 16/25 sq. mm 114 fixing of 3 phase lt shunt capacitor (3/6/9/12kvar) near starterof motor for agriculature consumers to be fixed with ms clamp of shape of size 2x10mm having two nos.holes for fixing of lt capacitors besides starter of consumer with the help of two no.machine screw. the starter shall be connected using pvc sheathed single core of 4 sq.mm ai. cable conforming to relevant is. the wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with ms compoundpvc tape roll. the ends of wire shall be properly crimped with lugsthimble etc.all material shall be supplied by the contractor except lt shunt capacitor (the lt shunt capacitor shall be supplied by nigam) ...

Jaipur Vidyut Vitran Nigam Limited - Rajasthan

32064827 supply, erection, installation and commissioning of material equipment for the work of release of ag connection in fy 2022 23 on turnkey basis in respect of sawai madhopur circle lot ii under the domain of jaipur discom supply of material ( all material shall be supplied as per specification enclosed with the bidding documents ) : 2 9 mtr. long pcc poles of 200 kg working load with factor of safty 2.5. 3 33 kv s / c lattice structure ( 36 ungalvanised with 1 nos 33 kv cross arm ( channel ) with required nuts and bolts. 4 11 / 0.433 kv, 40 kva aluminium wound bis level 2 completely self protected ( csp ) distribution transformers with provisio of lt bushing box 5 25 kva, 11 / 0.433 kv, aluminium woundbis level 2 ( star 1 ) completely self protected ( csp ) distribution transformers with provision of lt bushing box. 6 16 kva, 11 / 0.433 kv, aluminium woundbis level 2 ( star 1 ) completely self protected ( csp ) distribution transformers with provision of lt bushing box. 7 galvanised steel stay set 16x1800 mm 8 11 kv stay insulator 9 galvanised steel stay wire 7 / 10 swg 10 stay set clamps suitable for 9 mtr. long pcc poles 11 h / w for disc insulators 45kn t&c type 12 disc insulators 45kn t&c type 13 m.s. nuts & bolts ( assorted size ) 14 acsr rabbit conductor 15 11 kv v cross arm with top hamper and clamps ( angle ) 16 galvanized m.s. froged 11 kv pin 17 11 kv pin insulator 18 11 / 0.4 kv s / s structure set for 3 ph 40 / 25 / 16 kva transformer on double pole 19 horn gap fuse set with post insulator 11 kv 20 ms rod type earthing set with wire & clamp with following details ( 1 no. galvanised m.s. rod 20 mm dia electrodes having3 meter length, 2 nos. galvanised earthing clamp of m.s.flat of size 50x6 mm 220 mm length. one welded with earthelectrode and loose to be bolted; 2 nos. galvanised bolts, nuts and spring washers and g.i.wire size 8 swg of 15 meter length ) 21 1.4 mtr channel 100x50x6 mm bracket with clamp 22 4c x 16 sq. mm. lt pvc insulated pvc sheathed cable ( armoured ) 23 m.s. angles 75 x 75 x 6 mm ( for guarding ) 24 three phase four wire whole current meter of rating 10 60 a having backlit lcd display with meter box ( free issue ) . 25 m.s. channel 75 x 40 x 6 mm ( for extension bracket ) 26 lt shunt capacotors 3 kvar 27 lt shunt capacotors 6 kvar 28 danger plate 29 11 kv line dp set 30 p.g. clamps for rabbit 31 g.s. earth wire 8 swg 32 erection of material: 33 trimming of tree branches / plants and preparing route approchases for proposed line. 34 excavation of pit in hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation / pit. 35 ( a ) height of poles / r.s.joist / m.s. rail / size of pit 36 9 mtr / 1.2mx0.6mx1.50 m deep 37 ( b ) lattice tower / size of pit 38 11.4 / 10.8 mtr / 1.5mx1.5m x1.80 m deep 39 ( c ) stay set / depth of pit 40 6x5 / 8 0.75x0.5x1.35m 41 excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation / pit. 42 ( a ) height of poles / r.s.joist / m.s. rail / size of pit 43 9 mtr / 1.2mx0.6mx1.50 m deep 44 ( b ) lattice tower / size of pit 45 11.4 / 10.8 mtr / 1.5mx1.5m x1.80 m deep 46 ( c ) stay set / depth of pit 47 6x5 / 8 0.75x0.5x1.35m 48 safe carriage of pcc poles including loading / un loading 49 c ) 9 mtr.long 200 kg. pcc pole 50 within10 kms. 51 above 10 km. & upto 30 km. add foreach km. or part thereof 52 above 30 km. add for each km. or part thereof ( 50 km ) 53 safe carriage of steel ( fabricated and unfabricated ) i.e.m.s. rails, r.s.joists, m.s.channels, m.s.angles, m.s.flat, g.i.stay sets, g.i. stay wire, g.i.wire nut & bolts etc. and acsr conductor including loading and unloading and stacking in nigam store / at work site 54 within10 kms. 55 above 10 kms. & upto 30 kms. add for each km.or part thereof. 56 above 30 kms. add for each kms. or partthereof. ( 50 km ) 57 safe carriage of insulator, hardware, cable etc.including loading / unloading and stacking in nigam.stores etc. 58 within10 kms. 59 above 10 kms. & upto 30 kms. add for each km.or part thereof. 60 above 30 kms. add for each kms.or part thereof. ( 50 km ) 61 safe carriage of fabricated lattice towers structures and sub station structures type ab, ab beams, isolators structures etc. including loading / unloading and stacking in the nigam. stores / at work site. 62 within10 kms. 63 above 10 kms. & upto 30 kms. add for each km.or part thereof. 64 above 30 kms. add for each kms.or part thereof. ( 50 km ) 65 safe carriage of 11 / .4 kv 3 phase distribution transformer including loading / unloading and stacking in nigam.stores etc. 66 10 &16 kva 67 within10 kms. 68 above 10 kms. & upto 30 kms. add for each km.or part thereof. 69 above 30 kms. add for each kms.or part thereof. ( 50 km ) 70 25 & 40 kva 71 within10 kms. 72 above 10 kms. & upto 30 kms. add for each km.or part thereof. 73 above 30 kms. add for each kms.or part thereof. ( 50 km ) 74 erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. the support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item no. 5.6 the remaining portion of the pit will be back filled with soil. the nuts & bolts will be provided by the contractor as per nigams specification for which payment will be made at the prevailing store issue rates. the cost muffing and grouting will be paid extra. 75 lattice structure 76 erection of pcc poles in excavated pit with fixing of brackets, cross arms & top hampers as required in alignment after checking the same with plumb line. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractor as per nigams specification for which the payment will be made at the prevailing discom store issue rates. 77 in rural area 78 pcc poles 9 mtr. long ( 200kg. ) 79 erection & assembly of 2 pole structures ofof steel supports or of pcc poles in excavated pit in alignment afterchecking the same with plumb line. including fixing of top bracing of m.s. channels with pilot plates and clamps. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractoras per nigams specfication for which the payment will be made at the prevailing discom store issue rates. 80 pcc poles 9 mtr. long ( 200kg. ) 81 erection & fixing of g.i.stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.the work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension.size of stay set / stay wire 82 6x5 / 8 with 7 / 10 swg stay wire 83 providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement, river sand and 12 mm to 20 mm graded blast crusher broken in pit / foundation according to the size / type of supports / stay set including compaction / curing for 21days in steel plates shuttering / farmer base. ( 1.2x1.2 x2.1 m ) / tower 84 fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub station. 85 fixing of guarding bracket arms with clamp on erected support as per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 86 11 kv line 87 fixing of earth wire clamp on erected supportas per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 88 fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. the nuts &bolts are to be provided by the contractor as per nigams specification for which payment will be made as perprevailing discom store issue rates. 89 11 kv line 90 fixing and assembly of disc. point channel pair with pilot plates & clamps on erected single pole structure as per design. the nuts & bolts are to be provided by the contractor as per nigams specification for which payment will be made as per prevailingdiscom store issue rates. 91 11 kv line 92 fixing of 11kv b&s / t&c type disc insulator of 11kv lines ( each unit consiting of 1nos.disc.& 1set of h / w ) on terminal point including fixing of hardware and strips. 93 fixing of 11 kv pininsulator with pins. 94 ssembly and installation of horn gap fuse set ( set of 3 nos ) on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. the nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing discom store issue rates. 95 11kv horn gap fuse set. 96 installation testing as per nigams norm & commissioning of11 / 0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on hv&lv side, crimping of lugs / clamping earth connections of body and neutral of transformer with wire / strip ( as already provided with earthing ) complete in all respect. the pg clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing discom store issue rates. 97 10 & 16 kva 98 25 & 40 kva 99 fixing of danger plates on supports / structure 100 fixing of pg clamp of weasel / rabbit conductor 101 laying, jointing , stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire / p.g. clamps aluminium jointing sleeves will be used for jointing the conductor. the line must stand at proper voltage on charging. the contractor will be provide p.g. clamps for which payment will be made as per prevailing discom store issue rates. 102 acsr rabbit 103 laying, jointing, stringing, tensioning and clamping of g.i.earthwire continuosly on single / double pole by using earth clamps / nuts & bolts with washers and earth reel etc.including proper binding at each end.the nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing discom store issue rates. 104 ( b ) in rural area 105 g.i.earth wire 8 swg 106 drawing & strining of g.i 4 wire over the guarding brackets for guarding of road crossing / p&t crossing / railway track crossing ( for one span only ) with cross g.i wire laces at an intraval of two meter each or required as per location using eye bolt nuts. 107 8 swg with laces of 10 swg 108 earthing of line for all type of supports as per rec construction standards using stay wire / gi wire with one pcs of m.s. rod 20mm dia each 3 meter long and driving into earth by mechanical means ms rod, ms flat & stay wire will be supplied by the contractor. ifmaterial is supplied by the contractor the payment will be made as per prevailing discom store issue rates. ( in case of pcc poles earthing mustbe connected with earthwire already available on pcc pole at bottom ) 109 earthing of 11 / 0.4 kv distribution transformer / sub station with 3 pieces of m.s. rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. the work includes flattening of top ends of m.s. rod drilling a hole of 9 / 16 dia. at flattened top and tightening of m.s. flat 50x6mm ( having 3 hole 2ends and 1mm middle ) with nuts and bolts with m.s. rod. top end hole. the flat will also be welded with m.s. rod. the end will be connected to equipments as under as under in sequence. 110 fixing of three phase meter cummeter box ( complete unit ) at the premises of existing / new consumerswith 4 nos anchor fastners with rust proof size m 6x50 mm on the wall as per the positionof holes already provided on the meter box. the meter box must be housed perfectly vertical / plumb line, anchor fasteners are to be supplied / provided by the contractor including safe carriage from s / d store to consumers site and depositing removed meter and meter box if any in s / d store ) . 111 in rural area 112 laying of 1100 volt heavy duty armoured xlpe cable of aluminum coudctor of following size conforming to is: 7098 ( pt i ) ( latest amended ) overhead service line from pole to meter terminals for release of new lt connections / replacement of damaged / obsolete service line ( except agriculture one ) . the cable must be fixed on wall with clamps / hooks properly at a interval of one meter. 113 4 core 16 / 25 sq. mm 114 fixing of 3 phase lt shunt capacitor ( 3 / 6 / 9 / 12kvar ) near starterof motor for agriculature consumers to be fixed with ms clamp of shape of size 2x10mm having two nos.holes for fixing of lt capacitors besides starter of consumer with the help of two no.machine screw. the starter shall be connected using pvc sheathed single core of 4 sq.mm ai. cable conforming to relevant is. the wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with ms compoundpvc tape roll. the ends of wire shall be properly crimped with lugsthimble etc.all material shall be supplied by the contractor except lt shunt capacitor ( the lt shunt capacitor shall be supplied by nigam ) ...

Jaipur Vidyut Vitran Nigam Limited - Rajasthan

32064822 supply, erection, installation and commissioning of material equipment for the work of release of ag connection in fy 2022 23 on turnkey basis in respect of tonk circle lot i under the domain of jaipur discom against tn 523 supply of material (all material shall be supplied as per specification enclosed with the bidding documents): 2 9 mtr. long pcc poles of 200 kg working load with factor of safty 2.5. 3 33 kv s/c lattice structure (36 ungalvanised with 1 nos 33 kv cross arm(channel) with required nuts and bolts. 4 11/0.433 kv, 40 kva aluminium wound bis level 2 completely self protected (csp) distribution transformers with provisio of lt bushing box 5 25 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 6 16 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 7 galvanised steel stay set 16x1800 mm 8 11 kv stay insulator 9 galvanised steel stay wire 7/10 swg 10 stay set clamps suitable for 9 mtr. long pcc poles 11 h/w for disc insulators 45kn t&c type 12 disc insulators 45kn t&c type 13 m.s. nuts & bolts (assorted size) 14 acsr rabbit conductor 15 11 kv v cross arm with top hamper and clamps ( angle) 16 galvanized m.s. froged 11 kv pin 17 11 kv pin insulator 18 11/0.4 kv s/s structure set for 3 ph 40/25/ 16 kva transformer on double pole 19 horn gap fuse set with post insulator 11 kv 20 ms rod type earthing set with wire & clamp with following details(1 no. galvanised m.s. rod 20 mm dia electrodes having3 meter length, 2 nos. galvanised earthing clamp of m.s.flat of size 50x6 mm 220 mm length. one welded with earthelectrode and loose to be bolted; 2 nos. galvanised bolts, nuts and spring washers and g.i.wire size 8 swg of 15 meter length) 21 1.4 mtr channel 100x50x6 mm bracket with clamp 22 4c x 16 sq. mm. lt pvc insulated pvc sheathed cable (armoured) 23 m.s. angles 75 x 75 x 6 mm (for guarding) 24 three phase four wire whole current meter of rating 10 60 a having backlit lcd display with meter box (free issue). 25 m.s. channel 75 x 40 x 6 mm (for extension bracket) 26 lt shunt capacotors 3 kvar 27 lt shunt capacotors 6 kvar 28 danger plate 29 11 kv line dp set 30 p.g. clamps for rabbit 31 g.s. earth wire 8 swg 32 erection of material: 33 trimming of tree branches/plants and preparing route approchases for proposed line. 34 excavation of pit in hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 35 (a) height of poles/r.s.joist/m.s. rail /size of pit 36 9 mtr/ 1.2mx0.6mx1.50 m deep 37 (b) lattice tower /size of pit 38 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 39 (c)stay set/depth of pit 40 6x5/8 0.75x0.5x1.35m 41 excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 42 (a) height of poles/r.s.joist/m.s. rail /size of pit 43 9 mtr/ 1.2mx0.6mx1.50 m deep 44 (b) lattice tower /size of pit 45 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 46 (c)stay set/depth of pit 47 6x5/8 0.75x0.5x1.35m 48 safe carriage of pcc poles including loading / un loading 49 c) 9 mtr.long 200 kg. pcc pole 50 within10 kms. 51 above 10 km. & upto 30 km. add foreach km. or part thereof 52 above 30 km. add for each km. or part thereof (50 km) 53 safe carriage of steel( fabricated and unfabricated) i.e.m.s. rails, r.s.joists, m.s.channels, m.s.angles, m.s.flat, g.i.stay sets, g.i. stay wire, g.i.wire nut & bolts etc. and acsr conductor including loading and unloading and stacking in nigam store /at work site 54 within10 kms. 55 above 10 kms. & upto 30 kms. add for each km.or part thereof. 56 above 30 kms. add for each kms. or partthereof. (50 km) 57 safe carriage of insulator, hardware, cable etc.including loading/unloading and stacking in nigam.stores etc. 58 within10 kms. 59 above 10 kms. & upto 30 kms. add for each km.or part thereof. 60 above 30 kms. add for each kms.or part thereof. (50 km) 61 safe carriage of fabricated lattice towers structures and sub station structures type ab, ab beams, isolators structures etc. including loading/unloading and stacking in the nigam. stores / at work site. 62 within10 kms. 63 above 10 kms. & upto 30 kms. add for each km.or part thereof. 64 above 30 kms. add for each kms.or part thereof.(50 km) 65 safe carriage of 11/.4 kv 3 phase distribution transformer including loading/unloading and stacking in nigam.stores etc. 66 10 &16 kva 67 within10 kms. 68 above 10 kms. & upto 30 kms. add for each km.or part thereof. 69 above 30 kms. add for each kms.or part thereof. (50 km) 70 25 & 40 kva 71 within10 kms. 72 above 10 kms. & upto 30 kms. add for each km.or part thereof. 73 above 30 kms. add for each kms.or part thereof. (50 km) 74 erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. the support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item no. 5.6 the remaining portion of the pit will be back filled with soil. the nuts & bolts will be provided by the contractor as per nigams specification for which payment will be made at the prevailing store issue rates. the cost muffing and grouting will be paid extra. 75 lattice structure 76 erection of pcc poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractor as per nigams specification for which the payment will be made at the prevailing discom store issue rates. 77 in rural area 78 pcc poles 9 mtr. long(200kg.) 79 erection & assembly of 2 pole structures ofof steel supports or of pcc poles in excavated pit in alignment afterchecking the same with plumb line. including fixing of top bracing of m.s. channels with pilot plates and clamps. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractoras per nigams specfication for which the payment will be made at the prevailing discom store issue rates. 80 pcc poles 9 mtr. long(200kg.) 81 erection & fixing of g.i.stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.the work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension.size of stay set/stay wire 82 6x5/8 with 7/10 swg stay wire 83 providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.(1.2x1.2 x2.1 m)/tower 84 fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub station. 85 fixing of guarding bracket arms with clamp on erected support as per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 86 11 kv line 87 fixing of earth wire clamp on erected supportas per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 88 fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. the nuts &bolts are to be provided by the contractor as per nigams specification for which payment will be made as perprevailing discom store issue rates. 89 11 kv line 90 fixing and assembly of disc. point channel pair with pilot plates & clamps on erected single pole structure as per design. the nuts & bolts are to be provided by the contractor as per nigams specification for which payment will be made as per prevailingdiscom store issue rates. 91 11 kv line 92 fixing of 11kv b&s/t&c type disc insulator of 11kv lines(each unit consiting of 1nos.disc.& 1set of h/ w ) on terminal point including fixing of hardware and strips. 93 fixing of 11 kv pininsulator with pins. 94 ssembly and installation of horn gap fuse set (set of 3 nos)on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. the nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing discom store issue rates. 95 11kv horn gap fuse set. 96 installation testing as per nigams norm & commissioning of11/0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on hv&lv side, crimping of lugs/clamping earth connections of body and neutral of transformer with wire/strip (as already provided with earthing) complete in all respect. the pg clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing discom store issue rates. 97 10 & 16 kva 98 25 & 40 kva 99 fixing of danger plates on supports/structure 100 fixing of pg clamp of weasel /rabbit conductor 101 laying, jointing , stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire/p.g. clamps aluminium jointing sleeves will be used for jointing the conductor. the line must stand at proper voltage on charging. the contractor will be provide p.g. clamps for which payment will be made as per prevailing discom store issue rates. 102 acsr rabbit 103 laying, jointing,stringing,tensioning and clamping of g.i.earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.the nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing discom store issue rates. 104 (b) in rural area 105 g.i.earth wire 8 swg 106 drawing & strining of g.i 4 wire over the guarding brackets for guarding of road crossing /p&t crossing/railway track crossing (for one span only)with cross g.i wire laces at an intraval of two meter each or required as per location using eye bolt nuts. 107 8 swg with laces of 10 swg 108 earthing of line for all type of supports as per rec construction standards using stay wire/gi wire with one pcs of m.s. rod 20mm dia each 3 meter long and driving into earth by mechanical means ms rod, ms flat & stay wire will be supplied by the contractor. ifmaterial is supplied by the contractor the payment will be made as per prevailing discom store issue rates.(in case of pcc poles earthing mustbe connected with earthwire already available on pcc pole at bottom) 109 earthing of 11/0.4 kv distribution transformer /sub station with 3 pieces of m.s. rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. the work includes flattening of top ends of m.s. rod drilling a hole of 9/16 dia. at flattened top and tightening of m.s. flat 50x6mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with m.s. rod. top end hole. the flat will also be welded with m.s. rod. the end will be connected to equipments as under as under in sequence. 110 fixing of three phase meter cummeter box(complete unit)at the premises of existing/new consumerswith 4 nos anchor fastners with rust proof size m 6x50 mm on the wall as per the positionof holes already provided on the meter box. the meter box must be housed perfectly vertical/plumb line,anchor fasteners are to be supplied/provided by the contractor including safe carriage from s/d store to consumers site and depositing removed meter and meter box if any in s/d store). 111 in rural area 112 laying of 1100 volt heavy duty armoured xlpe cable of aluminum coudctor of following size conforming to is: 7098 (pt i) (latest amended) overhead service line from pole to meter terminals for release of new lt connections/replacement of damaged/obsolete service line (except agriculture one). the cable must be fixed on wall with clamps /hooks properly at a interval of one meter. 113 4 core 16/25 sq. mm 114 fixing of 3 phase lt shunt capacitor (3/6/9/12kvar) near starterof motor for agriculature consumers to be fixed with ms clamp of shape of size 2x10mm having two nos.holes for fixing of lt capacitors besides starter of consumer with the help of two no.machine screw. the starter shall be connected using pvc sheathed single core of 4 sq.mm ai. cable conforming to relevant is. the wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with ms compoundpvc tape roll. the ends of wire shall be properly crimped with lugsthimble etc.all material shall be supplied by the contractor except lt shunt capacitor (the lt shunt capacitor shall be supplied by nigam) ...