Medical Health And Family Welfare - Rajasthan

37748513 tender for electrical work phc building janunda, district pali., 1 ( electrical bsr 2022 rajasthan ) wiring of light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) in recessed isi marked mms ( is:9537 p iii ) virgin material pvc conduit & its isi marked ( is:3419 1988 ) accessories, round tiles, 1.2 mm thick hot dipped galvanized modular box with earth terminal, 10a modular switch, modular face plate with grid plate, 3 pin ceiling rose / holder / 3 way connector, screws, making connections, testing etc. as required. for specification of copper conductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr. short point ( up to 3 mtr. ) 2 medium point ( up to 6 mtr. ) 3 long point ( up to 10 mtr. ) 4 wiring of twin control light point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) in recessed isi marked mms ( is:9537 p iii ) pvc conduit & its isi marked ( is:3419 1988 ) accessories, round tiles, 2 nos hot dipped galvanized m.s modular box of 1.2 mm thick with earth terminal, 2 nos10 a two way modular switch, 3 pin ceiling rose / holder / 3 way connector , modular face plate with grid plate, screws, making connections, testing etc. as required. for specification of copper conductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr. medium point ( up to 6 mtr. ) 5 long point ( up to 10 mtr. ) 6 wiring of 3 / 5 pin 6 amp. light plug point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) in recessed isi marked mms ( is:9537 p iii ) pvc conduit & its isi marked ( is:3419 1988 ) accessories, hot dipped galvanized modular box of 1.2 mm thick with earth terminal, 10 a modular switch, 3 / 5 pin 6 a modular socket, modular face plate with grid plate, screws, making connections, testing etc. as required. for specification of copper conductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr. on board 7 supplying and fixing of power plug point with modular accessories as per pwd specification for electrical works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal / connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of isi marked modular 16 amp. switch ( is :3854 ) and 6 / 16 amp. socket outlet ( is:1293 ) making connection , testing , etc. as required. for specification of wiring accessories refer chapter e 07 related item & for additional technical parameters of product / work refer annexure a attached with this bsr 8 s&f following sizes ( dia. ) of isi marked virgin material mms ( is:9537 p iii ) pvc conduit along with isi marked ( is:3419 1988 ) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. for additional technical parameters of product / work refer annexure a attached with this bsr. 20 mm 9 25 mm 10 32 mm 11 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from 99.90 % purity copper, class 5 stranding in acc. to is:8130 / iec 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation pvc type a / c / d , flame retardant as per is 10810 53, better amperage rating as per is:3961 part 5, in existing surface or recessed pvc / ms conduit / casing capping making connections with copper lugs of suitable size, ferrules, testing etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of product / work refer annexure a attached with this bsr. 1 x 1.5 sq.mm 12 2 x 2.5 sq. mm. + 1x1.5sqmm 13 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 14 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. 15 1 x 4.0 sq.mm 16 4 x 6.0 sq.mm 17 4 x 10.0 sq.mm 18 providing & fixing of isi marked surface type buzzer ( is:2268 1994 ) with cm / l no. printed including making connection testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 19 p & f phenolic laminated sheet 2.0 mm thick of following size . including screws, cup washer as required.for additional technical parameters of product / work refer annexure a attached with this bsr. 75 mm dia 20 p & f 1.2mm thick m.s. recessed fan box, hexagonal / round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 21 providing & fixing of modular type 120 w step fan regulator duly isi marked ( is 11037:1984 ) with cm / l no. printed made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with ip 20 rating , including all as per pre approved by engineer in charge, making connections, testing etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr. 5 step fan regulator 2 module 360 dgree rotating 22 providing & fixing of following modular accessories as per pwd specification for electrical works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with ip 20 rating , including all as per pre approved by engineer in charge, making connections, testing etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr. blanking plate 23 25 amp. 2 module motor starter with on / off push button 24 providing & fixing of modular type lockable feature socket duly made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with ip 20 rating , including all as per pre approved by engineer in charge, making connections, testing etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr. 25 amp. 2 module socket 25 providing & fixing of extra down rod of 15 mm dia . erw ( electrical resistance welded ) of 1.6mm nominal thick medium duty steel pipe including cutting, threading, drilling, fixing quarter pin etc as reqd. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 26 p & f of gravity louver shutter of superior quality made out of frame of 18 swg m.s. sheet & louvers made from 24 swg ms sheet with enamel paint including cost of nuts, bolts, etc as reqd. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr .up to 380 mm size 27 supplying and drawing pe insulated & pvc sheathed unarmoured telephone cable with 0.5 mm dia. solid annealed electrolytic grade bare copper conductor as per is: 8130 / 84 &confirming to tec specification gr / wir / 06 03 march 2002 in existing surface or recessed conduit / casing capping. including ferruling on each pair for identification etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr. 3 pair 28 5 pair 29 50 pair 30 20 pair 31 p & f krone module with base frame in the recess / surface made out of 1.2 mm thick sheet steel box, front openable, having locking arrangements duly powder painted, including dressing, ferruling and punching of telephone cable with krone tool etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr. 20 pairs 32 50 pairs 33 p & f 1.2 mm thick g. i. / m .s. sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes ( nominal size ) in recessed / surface as required.for additional technical parameters of product / work refer annexure a attached with this bsr. 1.2 mm thick m. s. sheet boxes 175mm x 100mm x 60mm 34 p & f paper phenolic resin bonded laminates confirming to is : 2036 1995 for boxes / frames including making holes for switches etc, with brass screws, washers / zinc plated nut and bolts as required. for additional technical parameters of product / work refer annexure a attached with this bsr. 3.0 mm thick 35 providing & fixing of flush type non modular single line telephone jack made out fromindustrial grade polycarbonate or fire resistant abs material, including making connection testing etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 36 supply, drawing and testing of 4 pair, 23 awg solid bare copper wire insulated with pvc, utp ( unshielded twisted pair ) , category 6, class e, 100 ohm impedance, indoor cable as per latest ammendments of ansi / tia / eia 568 , the copper conductors should be balanced twisted in pairs, seperated by a cross member fluted pair divider & protected by pvc jacket. certified performance in a 4 connector configuration upto 100 mtrs channel requirements & transmission frequencies up to 250 mhz. in existing ms / pvc conduits / casing capping including making connections to information outlets and patch panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 37 supply and installation of unsheilded / 360 degree sheilded information outlets made of high impact plastic body with abs, fr grade halogen free material with provision for protection against dust in jack, suitable for cat 6 / 6a application complying to latest ammendments, according. to cat. 6 / 6a channel, it should support channel as well as components requirements of cat.6 / 6a standards at frequencies of up to 250 to 500 mhz. cat 6 / 6a unshielded / shielded jack should be suitable to terminate 4 pair, 23 / 24 awg solid / stranded wire diameters, using 100 ohm unshielded / shielded balance twisted pair cable, the jack should have tooless / impact termination on reliable copper tin plated insulation displacement contact, with easy lock mechanism, it supports iec 60603 7 4 and complied with ansi / tia / eia 568 c.2 standard. jack should be rj11, rj12 & rj45 compatible. should support ethernet 1.2 gb / s atm, digital video and broadband / baseband analog video, voice over internet protocal ( voip ) specifications in existing modular / ms boxes along with necessory connections as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . cat 6, un sheilded information outlet 38 supply & fixing of square faceplate for flush / surface mount information outlets single / dual or quad aperture , material should be pc+abs body, suitable for rj45 unshielded / shielded connection modules. should match with i. o. oem. dimensions should be 86mm x 86mm as required complete in all respect. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . single aperture 39 providing & fixing of 240 / 415 v ac mcb with positive isolation of 10 ka breaking capacity ( b / c / d tripping characteristic as per type of load and site requirement ) 4 kv impulse withstand voltage, isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted in existing distribution board / sheets, minimum electrical operation 20, 000 upto 20 a rating and 10, 000 upto 63 a, 5000 for 80 a & above rating including making connections, testing etc. as required. oem shall have submit nabl / cpri / erda accrediated lab type test reports & all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr. single pole mcb ( with b / c curve tripping characteristics ) 6 a to 32 a rating 40 triple pole mcb ( with b / c curve trippingcharacteristics ) 6 a to 32 a rating 41 four pole mcb ( with b / c curve tripping characteristics ) 6 a to 32 a rating 42 50 / 63 a rating 43 providing & fixing of recessed / surface mounting heavy duty horizontal type double door ( metal / glazed ) distribution board with metal end box made out from galvanized steel / crca sheet not less then 1.2 mm thick  conforming to is 8623 1 & 3 /   iec 61439 1 & 3, powder painted complete with reversible door ( for double door db only ) 100 amp.  insulated copper bus bar / shorting link , copper neutral link, copper earth link , color coded interconnecting wire set  of suitable rating and din bar, masking sheet,   making internal db  terminations with copper lugs, ferrules,   detachable gland plate, including making connections, testing etc. as required. oem shall have submit nabl / cpri / erda accrediated lab type test reports & all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr. metal door ( three phase ) ik 09 and ip 43 with metal end box 6 way 44 8 way 45 providing & fixing of 240 / 415 v residual current circuit breaker ( rccb ) conforming to ( is:12640 1 ) / iec 61008 1 , rated 4 kv impulse withstand voltage truly current operated and shall operate on cbct mechanisum, provision for pad lock, min. operation 10, 000 upto 63 a rating and 5000 for 100 a rating and minimum phase termination capacity of 35 sq.mm. rigid wire , ip 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. oem shall have submit nabl / cpri / erda accrediated lab type test reports & all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr. four pole 100 / 300 ma sensitivity 63 a rating 46 providing & fixing of recessed / surface mounting heavy duty vertical tpn distribution board with metal end box with provision of incomer suitable for 3 / 4 pole mccb and sp / tp mcb as outgoing , made out from galvanized steel / crca sheet not less then 1.2 mm thick  conforming to is 8623 1 & 3 /   iec 61439 1 & 3. powder painted with reversible door ( for double door db only ) complete with insulated 160 ( upto 160 a incomer ) / 250 amp.  copper bus bar, neutral bars with shrouds,   earth bar , color coded interconnecting wire set  of suitable rating and din bar, masking sheet,   making internal db  terminations with copper lugs, ferrules,   detachable gland plate, including making connections, testing etc. as required.  oem shall have submit nabl / cpri / erda accrediated lab type test reports & all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr. double door ip 43 & ik 09 with provision of incomer mccb 160 a rating with metal end box 6 way 47 supply and installation of high tensile low carbon steel rod molecularly bonded with 99.9 % copper thickness ( 250 microns ) and confirming to ul 467, is / iec 62561 2 of following size and length and as per point mentioned ( a ) , ( b ) , [ c ) , ( d ) , ( e ) below : ( a ) bore a hole of dia. 100 mm of required length, place the rod in the centre of hole ( b ) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, cpri / erda tested with rms capacity of minimum 30 ka for withstanding 1 second .to ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. the compound shall be tested form nabl acredeated lab for low resistivity ( less than 0.12 ohm meter ) & high conductivity in nature with carbon as a major content as per referance of is 3043 1987, ieee 80 2013 ( clause 14.5d ) , ieee 837 & ier 1956 with latest amendemnts © connect the rod with copper strip / conductor / wire with suitable clamp made from tinned copper and ss 304 bolt. ( d ) place heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height 250 to 300 mm. ( d ) testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. ( e ) test certificates for confirming above standards from oem is mandatory. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 17.2 mm thick and 3 mtr. long 48 supply & laying following size earth strip in horizontal or vertical run in surface by means of earth strip dmc insulator including riveting / soldering / welding, jointing shall be done by overlapping and with 2 set of brass ( for cu strip ) / gi ( for gi strip ) nut bolt & spring washer spaced at 50cm making connection etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 25mm x 3mm copper strip 49 25mm x 3mm g.i. ( hot dipped ) strip 50 providing & fixing of bee star rated copper wounded double ball bearing capacitor start, aluminium body & metallic blade ceiling fan conforming to all the performance requirements laid down in is 374:2019 including all amendments, as applicable ; & carry bis licensing ( i.e. isi marking ) with down rod up to 80 cm with secondary support safety cable ( steel rope ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 1200 mm sweep bee 1 star rated ( service value >=4.0 to < 4.5 ) 51 providing & fixing of heavy duty capacitor start, copper wound double ball bearing 900 / 1400 rpm single phase exhaust fan conforming to is:2312 isi marked in existing opening including making connections testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr .300 mm sweep ( 900 / 1400 rpm ) 52 providing & fixing of of double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor , making connections, testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 225 mm sweep 53 providing & fixing of 450 mm sweep oscillating type wall mounting / pedestal type fans with three speed, on and off position, sintered iron bush oil impregnated, with metal front and back 120 or more ribs guard; three no. aluminium blades, minimum air delivery 100 cum. / minute , minimum service value 1.11 cum. / min / watt, noise level should be <= 75 db, power consumption <= 120 watts, motor protection through thermal overload protection device, including fixing with anchor bolts, making connection testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . wall mounting type with adjustable vertical angle 54 providing & fixing of ip20 smd mid power led batten type integrated light fixture made from powder coated extruded aluminium housing with in built driver , system lumen efficacy ≥ 110 lm / watt output, internal surge protection of 2.5 kv with short & open circuit protection , thd < 10% , p. f.≥0.95, cri >80 , life time of minimum 50000 burning hours with , 70% of intial lumen maintaned till life ends , cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be of bis standard and trade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing on housing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 1170mm ( + / 10% ) led batten with min. lumen output 2200 lm 55 providing & fixing of ip20, 2x2 led surface / recessed mounting mid power smd type led light fixture not less than 50mm housing depth made from crca sheet steel housing, high purity / transmisivity uv stabilized non yellowish diffuser for uniform light distribution. high efficiency with 4 kv internal / external surge protection bis certified isolated driver having efficiency > 85% , with short & open circuit protection ( integral with light fixture ) . system lumen efficacy of ≥ 120 lm / watt , thd < 10 % , p.f.≥0.95, cri >80 , life time of minimum 50000 burning hours with , 70% of intial lumen maintaned till life ends , cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be of bis standard and trade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing on housing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . surface moutning minimum lumen output 3600 lm 56 providing & fixing of ip 20 led recessed / surface mounted, round / sqaure smd mid power led downlight with power coated die cast aluminum housing with uv stabilized non yellowish diffuser with bis complience 2.5 kv surge protected isolated driver, with short & open circuit protection, having efficiency > 85% . system lumen efficacy of ≥ 110 lm / watt, thd < 10 % , pf.≥0.95, cri >80, life time of minimum 50000 burning hours with , 70% of intial lumen maintaned till life ends , cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be of bis standard and trade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing on housing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . surface mounting ( with extruded alumn. housing ) minimum lumen output 1950 lm 57 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed arrmoured aluminium cable confirming to is:1554 p i / is :7098 p i of 1.1 kv with h4 grade electrolytic aluminium conductor confirming to is 8130 of purity >99.6 %, round / flat strip armouring of cables, inner / outer sheath confirming to is:5831 in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench / cable tray ( with cable tie ) including testing etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810.for additional technical parameters of product / work refer annexure a attached with this bsr. 6.0 sq. mm 4 core 58 10.0 sq. mm 4 core 59 16.0 sq. mm 4 core 60 50.0 sq. mm 3.5 core 61 supplying and making one end termination with nickel plated heavy duty brass single compression gland ( as per is 12943 1990 ) ) sibg type consisting of check nut, gland body, metal washer ( 3 nos. ) , outer seal rubber ring, compression nut, heavy duty aluminium lugs ( as per is 8309 1993 ) duly crimped with crimping tool, pvc tape as per is 8337 1976 of following size of pvc insulated & pvc sheathed / xlpe aluminium conductor cable of 1100 volt grade as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 4 x 6.0 sq.mm 62 4 x 10.0 sq.mm 63 3.5 x 50.0 sq.mm 64 sitc of ip 42 and general construction confirming to is:8623 : 1993, wall / free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point ( a ) , ( b ) , ( c ) , ( d ) , ( e ) , ( f ) , ( g ) , ( h ) as below: ( a ) thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided ( b ) complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam / neoprene rubber gasket of not less than 3mm thickness , required hardware , concealed hinged door with key type locking arrangement for equipment / switchgear earthed with 2.5 sq.mm braided copper wire. [ c ) interconnection between bus bar and switchgears / cable shall be rigidly supported and made out by flexible copper wires ( up to 63 amp ) and by solid bus bar ( >63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgear is to be paid extra ) ( d ) wiring between components within switchgear and incoming / outgoing cable shall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. ( e ) all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be ‘point to point’ ( no wire splitting or tee connections ) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. ( f ) floor mounted panel shall be mounted on base frame of ismc channel size 100 x 50 x 5 mm ( to be paid extra ) ( g ) tests: the insulation resistance ( with 1000 v megger ) and high voltage power frequency test ( by applying a voltage of 2.5kv for one minute ) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. the insulation resistance shall not be less than three megaohm. ct secondary current injection test shall also be carried out. ( h ) only outer surface area on all sides shall be measured & panel to be fabricated only from cpri approved fabricator only ( cpri test certificates to be submitted ) all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 65 supplying and fixing of aluminium ( iec 60105 iso 209 1, 2 ) / copper ( iec 60028 ) bus bar by means of smc / dmc type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . electrolytic grade aluminium bus bar 6010 grade 66 providing & fixing of is: 13875 & iec :61326 confirming led digital type ( up to 500 ) v range volt meter / direct ammeter / ct oertated ammeter / frequency meter / kwh meter / multi function meter / power analyzer of class 1 accuracy as per is : 1248 of size 96mm x 96 mm including making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . three phase ammeter with inbuilt selector switch 67 three phase voltmeter with inbuilt selector switch 68 providing & fixing of bis approved current transformer as per pwd specification for electrical works , isi marked as per is 2705 1992 / conforming to iec 60044 1, with secondary terminal of ct shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required current transformer ring type tape wound / resin cast wound as per is 16227 with, accuracy cl, ct ratio and burden as specified. isf<=5, cu cross section of secondary wire 1.5sqmm ( minimum ) , including all necessary support in existing panel including connection etc. as required . all as per pre approved by engineer in charge.all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . ring type tape wound ct c t class 1, ratio upto 150 / 5, burden 5 va 69 providing & fixing of 110 / 220 v, unibody led indicating lamp iec 60947 with integral circuit, ip 65 above panel & ip 20 terminal block, approx. body dia for panel not less then 20 mm, length min. 50mm, front led cover dia min. 29 mm, contact material phospher bronze for led, pcb contacts shall be of brass ( tin plated ) , impulse dielectric tested for 2.5 kv, rated insulation resistance shall be 100 m ohm at 500vdc including connection etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . red / yellow / green colour 70 providing & fixing of electrical insulating rubber matts as per pwd specification for electrical works, isi marked confirming to is: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 11 kv, class b 2.5 mm thick with proof voltage 22 kv ac ( rms ) and break down voltage 45 kv ac ( rms ) 71 sitc of 3 / 4 pole current limiting moulded case circuit breaker ( mccb ) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440 / 415 v, 50 hz; o / l & s / c settings , conforming to is / iec 60947 p 2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push ( test ) to trip, trip time less then 10 ms under s / c condition, breaking capacity ics = 100% icu. u imp =8 kv, rated insulation voltage 690 v. provision for uvr , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.oem shall have submit nabl / cpri / erda accrediated lab type test certificate before execution all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr. 4 pole mccb with thermal magnetic release up to 100 amp , 25 ka, adjustable o / l & adjustable s / c setting, 72 160 amp , 25 ka, adjustable o / l & adjustable s / c setting, 73 providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket / pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc ( uv stablization report submitted for uv cover ) / toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm / wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% , thd ( i ) <10% humidity 10% to 90% rh working temp 5c to 45c . driver current <750ma. the luminaire shall be bis certified and trade mark certified. life expectancy equal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min ≥ 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark / name engraved / embossing on die cast housing to allow traceability / authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 / lm80 ) certificate / report with liable warranty of product / accessories from oem shall be submitted. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . led street light fixture with minimum lumen output 3700 lm 74 providing & fixing of street light bracket made out from following size of b class , medium class g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with heavy duty pole clamp, saddles suitable fastners etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 32 mm dia. 75 sitc of single stage, water cooled, high speed ( 2880 rpm ) , horizontal, centrifugal, openwell submersible pumps set pre filled with coolent water and fitted with mechanical seal t / c vs t / c, thrust bearing shall be of carbon + s.s.the stator body of single phase pump shall be of ss and rest of all shall be of cast iron. all casting parts should be cathod electro deposition ( ced ) coated and other construction material should be confirming to is : 14220: 2018 . the overall performance of pump shall confirm to bee energy efficiency level of 3 star. valid bee certificate from oem must be submitted for the same. motor should be ie2 class as per iec 60034 2 1: 2007, iec 60034 30: 2008, & is12615:2011, including making connection etc as required complete in all respect. oem shall have submit nabl / cpri / erda accrediated lab type test certificate before execution. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 1.5 hp, 1 ø, ( 18 26 ) mtr, ( 126 78 ) lpm 76 supply & fixing of gi pipes confirming to is : 1239 p 1 ( 2004 ) with flanges duly screwed & welded including rubber washer, nuts & bolts of 8mm dia complete in all respect.all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . b class 50mm dia 77 sitc of contactor oem fabricated dol / star delta starter panel with switchgear selection as per type 2 cordinatiom chart and made out from 1.6 mm thick powder coated crca sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, illuminated on / off push buttons, ammeter, voltmeter, indicating lamps etc. suitable for following rating motors complete in all respect. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . for three phase submersible / mono block pump 3.0 hp to 5.0 hp ( star / delta starter ) 78 p / laying isi marked p.v.c. insulated submersible cable confirming to ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from 99.90 % purity copper, stranding in acc. to is:8130 / iec 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation pvc type a / c / d , flame retardant as per is 10810 53, better amperage rating as per is:3961 part 5, existing pipe / open trench / cable tray / on surface including making connection etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr. 6.0 sq.mm 3 core flat / round 79 supply, fabricating & installing following sizes of perforated hot dipped galvanized iron cable tray ( galvanized thickness not less then 50 microns ) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees, cross members and other accessories as required and duly suspended from the ceiling with gi suspenders including gi bolts & nuts , fastners, supports etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 150mm x 50mm x 1.6mm 80 p & f in position frame made out of m.s. angle ( riveted or welded ) finished with two coats of red oxide and two coats enamel paint including cutting, welding, holes etc.of following sizes as required.for additional technical parameters of product / work refer annexure a attached with this bsr. 50mm x 50mm x 6mm 81 35mm x 35mm x 5mm 82 providing & fixing of iso certified company made on load change over switch, front handle operated, four pole 415 v as per pwd specification for electrical works conforming to is / lec 60947 3 : 1999 including connections , testing etc. as required .in the following rating. appropriate type test certificate / oem test report shall be submitted . all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . open execution type 125 a 83 providing & fixing of vertical ( bee 5 star rated ) / horizontal ( bee 3 star rated ) storage water heater with outer casing made of engineering plastic sheet ( upto 25 ltr ) / metal rust proof body ( 35 & 50 ltr ) , glass line / titanium enamel coated pressure pump compatible 8 bar pressure inner tank, glass line coated , mineral filled heating element, stem type, snap action adjustable thermostat , dual indicating lamps injected puf insulation, multi function valve etc. as required held in position with 2 / 4 no. 10 / 12 mm anchor fastener, duly wired with 3 core 2.5 / 4.0 sqmm pvc insulated & sheathed copper conductor and 16 a / 25a three pin plug top with portable residual current device ( prcd ) , including making inlet, outlet flexible alloy connection, testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 15 ltr. 84 providing & fixing of vertical ( bee 5 star rated ) / horizontal ( bee 3 star rated ) storage water heater with outer casing made of engineering plastic sheet ( upto 25 ltr ) / metal rust proof body ( 35 & 50 ltr ) , glass line / titanium enamel coated pressure pump compatible 8 bar pressure inner tank, glass line coated , mineral filled heating element, stem type, snap action adjustable thermostat , dual indicating lamps injected puf insulation, multi function valve etc. as required held in position with 2 / 4 no. 10 / 12 mm anchor fastener, duly wired with 3 core 2.5 / 4.0 sqmm pvc insulated & sheathed copper conductor and 16 a / 25a three pin plug top with portable residual current device ( prcd ) , including making inlet, outlet flexible alloy connection, testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 25 ltr. 85 supply, installation, & testing of 19 1u rack mounted / surface mounted aluminum / crca 1.2mm powder coated, singlemode glass fiber optic cable patch panel / liu loaded with flangless / screwable duplex adapters for st / e 2000 / sc / lc / mt rj / pc type, it should have easy removable top plate with push buttons, there should be a splice tray installed in the patch panel / liu which can handle the fiber cores, splice tray should be pc+abs material, it should include accessories like mounting hardware, gormetts, heat shrink tubes / sleevs, screws, nuts to install the panel for rack / wallmount applications as per requirment complete in all respect. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 24 ports 86 supply , installation and testing of 4 pair, 100 ohm impedance, cat 6 / 6a / class e / ea patch cords should be constructed of minimum 23 / 24 awg, stranded bare copper cable with frpvc / lszh jacket, with an enhanced performance by factory moulded rj45 connectors with strain relief boots as per ansi / tia / eia 568 c.2 suitable for cat 6 / 6a application complying to latest ammendments category 6 / 6a standards, according. to tia568c.2, iso / iec 11801, en 50173, iec 60603 7 51, en 60603 7, ieee 802.3an minimum requirement for 1g base t to 10g base t performance. patch cords shall be straight thru cable compatible with both t568 a and t568 b wiring schemes, should support ieee 802.3af / ieee 802.3at for poe applications, minimum 750 to 1000 mating cycles in plug contacts for long durability, should support ethernet 10gbase t, 1.2 gb / s atm, token ring 4 / 16, digital video and broadband / baseband analog video, voice over internet protocal ( voip ) .all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . cat 6, u / utp ( unscreened / un sheilded twisted pair ) patch cord 1 mtr 87 supply & installation of ip 20 & ik 08 , ul listed wall mounted double section communication enclosure ( rack ) made from powder coated ( 60 to 80 micron ) crca sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door, vertical mounting rail 1.6 mm with umarking , with all round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. accessories like: 1 no of 19 1u horizontal cable manager, 1 no of 90 cfm 230v ac fan with 1 mts long cable, mounting hardware , 1 no of 19 1u, mountable socket strips with 5 nos of 5a universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with suitable anchor fastner etc as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 12 u rack with width 600 mm & depth 400 mm + 100 mm 88 supply , installation, testing and comissioning of managed layer 2 intelligent 10 / 100 ethernet switch providing 24 x 10 / 100 / 1000 mbps giga ethernet ports / with min 2 sfp giga ports ( provision for fiber giga connectivity ) with related lan base software including making connections etc as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 89 supply , installation, testing and comissioning of inverter type air cooled hi wall split type air conditioners with latest star rating system as per bee amended upto date complete with indoor unit ( idu ) , out door unit ( odu ) , surface / concealed copper refrigerant piping with insulation ( closed cell elastomeric nitrile rubber tubular pipe section ) upto 3 mtr ( idu to odu ) , copper power cable upto 3.5 mtr ( idu to odu ) , r 32 / r 410 green refrigerant, wireless remote control, suitable for working between 230v + / 10% with low & high voltage cutoff and 50 hz , single phase ac supply capable of performing cooling, dehumidification, air circulation of following capacity with scroll / rotary compressor. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 1.5 tr iseer not less then 3.8 90 supply, fixing and testing of following capacity iso certified company made wall mounted stabilizer having output voltage variation from 200 v to 250 v ( + / 5% ) with input voltage variation from 170 v to 260 v, time delay facility from 2 to 4 minute and high cutoff at 270 v with providing of 16 amp / 20 amp industrial plug top making connection etc complete in all respect. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 4 kva 91 supply & fixing ms powder coated stand suitable for 1.0 / 1.5 / 2.0 tr outdoor type of split ac. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 92 supply , installation, testing and comissioning of is:1475 marked self contained drinking water cooler with hermetically sealed compressor, non cfc refrigerent suitable for operation on 230v / 1ph / 50hz ac supply, full stainless steel ( ss304 ) body ( 0.8 mm thick ) and tank ( 0.5 mm thick ) , stainless steel water tray, minimum two nos brass chrome plated faucets and suitable drainage system complete in all respect with required height ms fabricated and painted angle iron frame ( cost of frame to be paid extra ) complete in all respect of the following capacity. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . cooling capacity 150 ltr. / hr. and storage capacity 150 ltrs 93 supply & fixing of dry powder agent ( as per is 4308:2019 ) , abc type fire extinguisher ( stored pressure type ) conforming to is:15683:2018 , powder coated internal & external surface deep drawn cylinder body of mild steel cr2 grade conforming to is: 513, squeeze grip forged brass release valve with inbuilt safety release device, diaphragm type, 0 to 28 bar range pressure gauge, 450 mm long epdm discharge tube, qr code for product traceability including fixing on wall with suitable anchor fasteners as required of following capacity. test certificates of all the parameters along with hydro test & burst test ( for cylinder body ) certificate from oem / external nabl accrediated lab is to be submitted. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 4 kg 94 p & f in position frame made out of m.s. angle ( riveted or welded ) finished with two coats of red oxide and two coats enamel paint including cutting, welding, holes etc.of following sizes as required.for additional technical parameters of product / work refer annexure a attached with this bsr. 40mm x 40mm x 5mm 95 p & f of industrial plug and socket conforming to iec 60309 1 / 2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. for additional technical parameters of product / work refer annexure a attached with this bsr. ip 67 surface / wall mounted socket. 32 a 3 pin ( 2p+e ) ...

Bhiwadi Integrated Development authority - Rajasthan

37385037 annual rate contract for maintenance works of electrical equipments in building under bida bhiwadi as per td 1 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from99.90 % purity copper, class 5 stranding in acc. to is:8130 / iec 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation pvc type a / c / d , flame retardant as per is 10810 53, better amperage rating as per is:3961 part 5, in existingsurface or recessed pvc / ms conduit / casing capping making connections with copper lugs of suitable size, ferrules, testing etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of product / work refer annexure a attached with this bsr 2 2 x 1.5 sq.mm 3 2 x 2.5 sq.mm 4 2 x 4.0 sq.mm 5 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 6 supply & drawing wiring for sub mains isi marked ( is:694 ) 1100 volts grade pvc insulated flat twin core sheathed solid aluminium conductor with 10 swg g.i. support wire duly clipped etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr6.0 sq.mm 7 providing & fixing of 240 / 415 v ac mcb with positive isolation of 10 ka breaking capacity ( b / c / d tripping characteristic as per type of load andsite requirement ) 4 kv impulse withstand voltage, isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted inexisting distribution board / sheets, minimum electrical operation 20, 000 upto 20 a rating and 10, 000 upto 63 a, 5000 for 80 a & above ratingincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 8 single pole mcb ( with b / c curve tripping characteristics ) 9 6 a to 32 a rating 10 50 / 63 arating 11 double pole mcb ( with b / c curve tripping characteristics ) 12 40 a rating 13 100 a rating 14 four pole mcb ( with b / c curve tripping characteristics ) 15 125 a rating 16 providing & fixing of 240 / 415 v isolatorisi marked is:13947 iii / conforming to iec 60947 3, suitable for ac22a utilization category, 4kv impulse withstand voltage, true contact indication, red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm.ip 20 contact protection and fitted in existing distribution board / sheetincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr 17 double pole isolator 18 30 a / 40 a rating 19 63 a rating 20 four pole isolator 21 63 a rating 22 80 a / 100 a rating 23 providing & fixing of recessed / surface mounting heavy duty horizontal type double door ( metal / glazed ) distribution board with metal end box made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3, powder painted complete with reversible door ( for double door db only ) 100 amp. insulated copper bus bar / shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar, masking sheet, making internal db terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 24 metal door ( single phase ) ik 09 and ip 43 with metal end box12 way ( 12+2 ) 25 metal door ( three phase ) ik 09 and ip 43with metal end box12 way 26 p & f of industrial plug and socket conforming to iec 60309 1 / 2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. for additional technical parameters of product / work refer annexure a attached with this bsrip 67 surface / wall mounted socket 27 16 a 3 pin ( 2p+e ) 28 32 a 3 pin ( 2p+e ) 29 providing & fixing of single / multi tone electronic call bell as per pwd specification for electrical works, including making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 30 providing & fixing of ding dong / musical chime bell as per pwd specification for electrical works, including making connection testing etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 31 providing & fixing of modular type switch / bell push duly isi marked ( is :3854 ) with cm / l no. printed and made out of unbreakable and fire retardant vergin uv stabilized polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , minimum width ofswitch toggle ( push part ) should not less then 20mm, includingall as per pre approved by engineer in charge, making connections, testing etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 32 10 a one way switch 33 16 a one way switch with ledindicator 34 providing & fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , includingall as per pre approved by engineer in charge, making connections, testing etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr6 / 16 ashuttered socket 35 providing & fixing of modular type 120 w step fan regulator duly isi marked ( is 11037:1984 ) with cm / l no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , includingall as per pre approved by engineer in charge, making connections, testing etc. as required.for additional technical parameters of product / work refer annexure a attached with this bsr5 step fan regulator 2 module 360 dgree rotating 36 providing & fixing of following modular accessories as per pwd specification for electrical works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , includingall as per pre approved by engineer in charge, making connections, testing etc. as required.for additional technical parameters of product / work refer annexure a attached with this bsr 37 rj 11 telephone jack singleline 38 rj 11 telephone jack double line 39 usb charger 1 a 1 m with bis mark 40 rj 45, cat 6 computer jack with shutter 41 supplying and fixing of power plug point with modular accessories as per pwd specification for electrical works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal / connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofisi marked modular 16 amp. switch ( is :3854 ) and 6 / 16 amp. socket outlet ( is:1293 ) making connection , testing , etc. as required. for specification ofwiring accessories refer chaptere 07related item & for additional technical parameters of product / work refer annexure a attached with this bsr 42 sitc of3 / 4pole current limiting moulded case circuit breaker ( mccb ) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440 / 415 v, 50 hz; o / l & s / c settings , conforming to is / iec 60947 p 2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push ( test ) to trip, trip time less then 10 ms under s / c condition, breaking capacity ics = 100% icu. u imp =8 kv, rated insulation voltage690 v.provision for uvr , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.oem shall have submitnabl / cpri / erda accrediated lab type test certificate before execution all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 43 3 pole mccb with thermal magnetic release 44 up to 100 amp , 25 ka, adjustable o / l & adjustable s / c setting, 45 125 amp , 25 ka, adjustable o / l & adjustable s / c setting, 46 4 pole mccb with thermal magnetic release 47 125 amp , 25 ka, adjustable o / l & adjustable s / c setting, 48 providing & fixing of iso certified company made four pole by pass change over switch conforming to is:13947 ( part 3 ) : iec:60947 3 1 and iec:60947 6 1, open execution type in the following ratings.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr .63 a 49 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed un arrmouredaluminiumcable confirming to is:1554 p i / is :7098 p i of 1.1 kv withh4 grade electrolyticaluminium conductor confirming to is 8130 of purity >99.6 %, inner / outer sheath confirming to is:5831in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench / cable tray ( with cable tie ) includingtesting etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810. for additional technical parameters of product / work refer annexure a attached with this bsr6.0 sq. mm 50 6.0 sq. mm 51 3 core 52 35.0 sq. mm 53 3.5 core 54 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed arrmouredaluminiumcable confirming to is:1554 p i / is :7098 p i of 1.1 kv withh4 grade electrolyticaluminium conductor confirming to is 8130 of purity >99.6 %, round / flat strip armouring of cables, inner / outer sheath confirming to is:5831in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench / cable tray ( with cable tie ) includingtesting etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810.for additional technical parameters of product / work refer annexure a attached with this bsr 55 50.0 sq. mm3.5 core 56 25.0 sq. mm3.5 core 57 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed un armoured coppercable confirming to is:1554 p i / is :7098 p i of 1.1 kv withelectrolytic gradecopper made of copper rodsconfirming to is 613 1964, of purity >99.7 %, inner / outer sheath confirming to is:5831in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench / cable tray ( with cable tie ) includingtesting etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810 for additional technical parameters of product / work refer annexure a attached with this bsr 58 2.5 sq. mm3 core 59 4.0 sq. mm3 core 60 add extra in item no. 11.1 to 11.4 for laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. up to 35 sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted ms clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 mtr. between clamps. 61 supplying and makingend termination with heavy aluminiumlugs ( pin / ring type ) confirming to is 8309 1993 & is 8337 1976 duly crimped with crimping tool, pvc tape etc of following size.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 62 25.0 sq.mm 63 35.0 sq.mm 64 50.0 sq.mm 65 supplying and makingend termination with heavy duty copper lugs ( any type ) confirming tois 8337 1976 duly crimped with crimping tool, pvc tape etc of following size.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 66 25.0 sq.mm 67 35.0 sq.mm 68 50.0 sq.mm 69 plate earthingas per is:3043 with hot dipped g.i. earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. g.i. b class watering pipe , including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke / charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 70 supply & laying following size earth stripin horizontal or vertical run in surface by means of earth strip dmc insulatorincluding riveting / soldering / welding, jointing shall be done by overlapping and with 2 set of brass ( for cu strip ) / gi ( for gi strip ) nut bolt & spring washer spaced at 50cm making connection etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 71 20mm x 3mm g.i. ( hot dipped ) strip 72 25mm x 6mm g.i. ( hot dipped ) strip 73 supply & laying following size earth wire in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection with gi / cu purity purity >95%thimble etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 6 swg g.i. ( hot dipped ) wire 74 making of hole in wall ( brick / stone ) of required and placing np 2 rcc pipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr .up to 457 mm size 75 providing & fixing of 400 mm sweepbldc technology oscillating type wall mounting / pedestal typefans with three speed, on andoff position, double wall bearing withfront and back 120 or moreribs guard; three no.blades, noise level should be <= 75 db, including fixing with anchor bolts, making connection testing etc. as required. ( with remote ) all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr .wall mounting type with service value 2.0 cmm / w, min. air delivery 71 cmm 76 providing & fixing ofbeestar rated copper wounded double ball bearing capacitor start, aluminium body & metallicblade ceilingfanconforming to all the performance requirements laid down in is 374:2019 including all amendments, as applicable ; & carry bis licensing ( i.e. isi marking ) with down rod up to 80 cm with secondary support safety cable ( steel rope ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr .1200 mm sweep bee 3 star rated ( service value >=5.0 to< 5.5 ) 77 providing & fixing of vertical ( bee 5 star rated ) / horizontal ( bee 3 star rated ) storage water heater with outer casing made of engineering plastic sheet ( upto 25 ltr ) / metal rust proof body ( 35 & 50 ltr ) , glass line / titanium enamel coated pressure pump compatible 8 bar pressure inner tank, glass line coated , mineral filled heating element, stem type, snap actionadjustable thermostat , dual indicating lampsinjected puf insulation, multi function valve etc. as required held in position with 2 / 4 no. 10 / 12 mm anchor fastener, duly wired with 3 core 2.5 / 4.0 sqmm pvc insulated & sheathed copper conductor and 16 a / 25a three pin plug top with portable residual current device ( prcd ) , including making inlet, outlet flexible alloyconnection, testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 25 ltr. 78 providing & fixing of stem type isi marked ( is 3017 / 85 ) snap action adjustable thermostat storage water heater including making connection testing etc. complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 79 providing & fixing of stem type isi marked ( is 3017 / 85 ) , snap action bipolar adjustable thermostat with built in auto thermal cut out of storage water heater including making connection testing etc. complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 80 providing & fixing 2 / 3 kwnickle plated, mineral filled heating element including making connection testing etc complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 81 providing & fixing of 13 mm brass withc.p. finished isi marked angle valve for storage water heater as required complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 82 providing & fixing of heavy dutyflexible alloy pipefor storage water heater for inlet and outletofsuitable length including the cost of nuts, washers etc complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 450 mm 83 charges for descaling of storage water heater including replacement of multi function valve as required. 84 providing & fixing of ip20 smd mid power led batten type integrated light fixture made from powder coated extruded aluminiumhousing with in built driver, system lumen efficacy = 110 lm / watt output, internal surge protection of 2.5 kv with short & open circuit protection , thd < 10% , p. f.=0.95, cri >80 , life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing on housing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 1170mm ( + / 10% ) led batten with min. lumen output 2200 lm 85 providing & fixing of ip 20 led recessed / surface mounted, round / sqauresmd mid power led downlight with power coated die cast aluminum housingwith uv stabilized non yellowish diffuser withbis complience 2.5 kv surge protected isolated driver, with short & open circuit protection, having efficiency > 85% . system lumen efficacy of = 110 lm / watt, thd < 10 % , pf.=0.95, cri >80, life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing.oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr .surface mounting ( with extruded alumn. housing ) minimum lumen output 2400 lm 86 providing & fixing of energy efficient / energy saving ip 20 led direct retrofit bulbin existing holder or fixture as required with system lumen efficacy =100 lm / watt output , pf 0.95 , cri >70, minimum life time of minimum25000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 / lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge . for additional technical parameters of product / work, refer annexure a attacheded with this bsr.18 / 20 watt 87 providing & fixing of ip 20 boxmade outfrom 1.2mm thick crca sheet steel with depth of minimun 30 mm and finished with powder coating andsuitable for mounting led tubeincludingside covers, holders , internal wiring to illuminate the single sided connection led tube. ( without tube ) .all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr .suitable for 4 led tube shape fixturefor single rod 88 providing & fixing of ik08ip65 protected top / bottom mounted led post top luminarie made of single piece constructionpowder coated die cast alluminium housing with uv stabalized clear / frosted polycarbonate diffuser andaluminium anodised with sand blast reflector. the system level luminous efficacy =100 lumen / w. smd leds is to be used, system cri>70, cct: 3000 / 4000 / 6500 k. the integral electronic driver must be potted & has a unique bis r number must be potted & has a unique bis r number constant current and internal / external surge protection device of min. 4kv ( l n ) and efficiency > 85%, pf>0.9, thd<10% and input voltage range of 140 270v ac at 50hz. system life of 50000 burning hours with 70% of initial lumens maintained . driver current <750ma.fixture must be in compliance with bis standards and trade mark certificate complete in all respect.oem must have its own in house nabl lab setup for all testing facilities forled fixtures. ( lm79 / lm80 ) certificate / report with liable warranty of product / accessories from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . minimum lumen output 4500 lm post top luminarie 89 providing & fixing ofik08 ip 66 protected high power led flood light system with single piece pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on led to achieve various beam angles, of high power led of 3 to 5 watt each . integrated potted driver as a unique bis r numberhaving efficiency more than 85 % and in compliance to bis certified and trade markcertificate. the system level luminaire efficacy >=125 lm / wt. led driver input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety .power factor >0.95 , thd ( i ) <10%, driver current <=750ma. driver should be phase to phase protection of 440 v for 4 hrs. electrical connector , surge protection min >=4kv internal and 10kv external but inside driver compartment, system life of 50000 burning hours with 70% of initial lumens maintained, cri>70 and cct 5700k±355k.manufactures word mark / name engraved / embossing / screen printing on die cast housing to allow traceability / authenticity. fixture shall be is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities forled fixtures. ( lm79 / lm80 ) certificate / report with liable warranty of product / accessories from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr .high power led flood light minimum lumen output 14800 lm 90 providing and fixing of ip 65 protected polycarbonate / polysterene fuse box moulded with inside knock outs of following size with hinged cover, transparent window, pu gasket, locking arrangement, duly holded with 2 nos. pole clamps of 20 mm x 3 mm flat with nut and bolts, the box shall be provided with din rail, 4 / 8 way 10.0 / 16.0sq.mm heavy duty connector, earth terminal, complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr .160 mm x 225 mm x 100 mm 91 providing & fixing of ip 65 protectedimpact resistant polycarbonate / polysterene enclosures with knock out for cable entry / out including fixing with nut, bolt, fatner etc as required complete in all respect of following sizes.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr .250 x 200 x 115 mm 92 providing and replacement ofball bearing of ceiling / exhaust fanand refixing the same at suitable location as requiredand as per oem recommendations. replacement of material or components shall be use as per guidelines of oem of original product. all the scrap material should be retained by the contractor. 93 rewinding of heavy duty exhaust fan motor including all necessary material, the motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enamelled wire with e class insulation material and making connections etc. as required. replacement of material or components shall be use as per guidelines of oem of original product. all the scrap material should be retained by the contractor. 600 mm sweep...

Department Of Local Bodies - Rajasthan

37370165 annual rate contract for electrical maintenance work with equipment for sub offices of municipal corporation bikaner. 1 wiring of light point / fan point / exhaust fan point / call bell point as per pwd specification for electrical works with isi marked 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade ( is:694 ) and 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) in recessed isi marked mms ( is:9537 p iii ) vergin material pvc conduit & its all accessories ( j.b. , bends etc. ) , round tiles, 18 swg g.i. box with earth terminal, 6 a switch , 3 pin ceiling rose / lamp holder / 3 point connector, 3.0 mm thick isi marked phenolic laminated sheet ( is : 2036 1995 ) , al. alloy / cadmium plated iron screws 20 mm cup washers etc. all as per pre approved by engineer in charge, making connections, testing etc. complete as required. for specification of copper conductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 . for additional technical parameters of products / work , refer annexure a attached with this bsr . short point ( up to 3 mtr. ) 2 medium point ( up to 6 mtr. ) 3 long point ( up to 10 mtr. ) 4 wiring of 3 / 5 pin 6 amp. light plug point as per pwd specification for electrical works with isi marked 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade ( is:694 ) and 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) in recessed isi marked mms ( is:9537 p iii ) vergin material pvc conduit & its all accessories ( j.b. , bends etc. ) , round tiles, 18 swg g.i. box with earth terminal of required size, 6 a switch, 3 / 5 pin 6 a socket, 3.0 mm thick isi marked phenolic laminated sheet ( is : 2036 1995 ) , al. alloy / cadmium plated iron screws 20 mm cup washers etc. all as per pre approved by engineer in charge, making connections, testing etc. complete as required. for specification of copper conductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07. for additional technical parameters of products / work , refer annexure a attached with this bsr . on board 5 short point ( up to 3 mtr. ) 6 medium point ( up to 6 mtr. ) 7 long point ( up to 10 mtr. ) 8 s&f following sizes ( dia. ) of isi marked mms ( is:9537 p iii ) vergin material pvc conduit as per pwd specification for electrical works along with its accessories ( is: 3419 ) as required in recess including cutting the wall, covering conduit and making good the same as required. all relative and latest acceptance tests reports by any nabl accredited lab for the conduit shall be submitted before execution & all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr .mms ( is:9537 p iii ) pvc conduit 25mm 9 mms ( is:9537 p iii ) pvc conduit 32mm 10 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from 99.99% purity copper, class 5 stranding in acc. to iec 60228 for lower watt loss , oxygen free ( <10 ppm ) for less chances of oxidization and higher silver content for gives better conductivity , insulation pvc type a or c , flame retardant as per is 10810 53, better amperage rating as per vde 0298 part 4, , in existing surface or recessed pvc / ms conduit / casing capping including all as per pre approved by engineer in charge, making connections, etc. as required. oem must have its own in house nablab setup for all testing facilities for wires. for additional technical parameters of products / work , refer annexure a attached with this bsr .1 x 1.5 sq.mm 11 2 x 1.5 sq.mm 12 1 x 2.5 sq.mm 13 2 x 2.5 sq.mm 14 2 x 4.0 sq.mm 15 supply & drawing wiring for sub mains as per pwd specification for electrical works with isi marked ( is:694 ) , 1100 volts grade pvc insulated flat twin core sheathed solid aluminium conductor with 10 swg g.i. support wire duly clipped including all as per pre approved by engineer in charge, making connections, as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of products / work , refer annexure a attached with this bsr . 4.0 sq.mm 16 6.0 sq.mm 17 10.0 sq.mm 18 supplying and laying isi marked p.v.c. insulated submersible cable as per pwd specification for electrical works confirming to is:694 and as per is 8130 : 2013 of 1.1 kv grade .wire should be made from 99.99% purity copper, class 5 stranding in acc. to iec 60228 for lower watt loss , oxygen free ( <10 ppm ) for less chances of oxidization and higher silver content for gives better conductivity , insulation pvc type a or c , flame retardant as per is 10810 53, better amperage rating as per vde 0298 part 4 including making connection etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. all as per pre approved by engineer in charge, making connections. for additional technical parameters of products / work , refer annexure a attached with this bsr . 2.5 sq.mm 3 core flat / round. 19 providing & fixing of 240 / 415 v ac mcb with positive isolation of breaking capacity not less than 10 ka ( b / c tripping characteristic as per type of load and site requirement ) 4kv impulse withstand voltage, as per pwd specification for electrical works with isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , ip 20 contact protection and fitted with existing distribution board / sheets, min. operation 20, 000 upto 32 a rating and 10, 000 upto 63 a, 5000 for 80 a rating including making connections, testing etc. as required. . oem shall have submit nabl / cpri / erda accrediated lab test reports before execution & all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . single pole mcb 6 a to 32 a rating 20 double pole mcb6 a to 32 a rating 21 four pole mcb40 a rating 22 four pole mcb50 63 a rating 23 providing & fixing of ik09 recessed / surface mounting heavy duty horizontal type sheet steel not less then 1.2 mm thick distribution board as per pwd specification for electrical works isi marked conforming to is 13032 & is 8623 / conforming to iec 61439 3. phosphatised / powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link , connecting wire of suitable rating and din bar, masking sheet, including making internal db terminations with copper lugs and with detachable gland plate, including making connections, testing etc. as required.oem shall have submit nabl / cpri / erda accrediated lab test reports before execution & all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . ip 43 double door ( single phase ) . 8 way ( 8 o / g +2 i / c ) 24 ip 43 double door ( three phase ) 8 way ( 24 o / g + 8 i / c ) 25 providing & fixing of isi marked ( is :3854 ) 6 amp. flush type non modular switch as per pwd specification for electrical works, made out from industrial grade polycarbonate or fire resistant abs material, minimum width of switch toggle ( push part ) should not less then 16 mm, brass terminal & captive screws including cutting hole in tile and making connection testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 26 providing & fixing of isi marked ( is :3854 ) 16 amp. flush type non modular switch as per pwd specification for electrical works, made out from industrial grade polycarbonate or fire resistant abs material , minimum width of switch toggle ( push part ) should not less then 16 mm, brass terminal & captive screws including cutting hole in tile and making connection testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 27 providing & fixing of of 3 pin 6 amp. flush type non modular socket as per pwd specification for electrical works, made out from industrial grade polycarbonate or fire resistant abs material, brass terminal with porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 28 providing & fixing of 3 / 6 pin 16 amp flush type non modular socket as per pwd specification for electrical works, made out fromindustrial grade polycarbonate or fire resistant abs material, brass terminal with porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 29 providing & fixing of isi marked ( is :3854 ) 6 amp. combined flush type non modular socket and switch set as per pwd specification for electrical works, made out from industrial grade polycarbonate or fire resistant abs material, minimum width of switch toggle ( push part ) should not less then 18 mm, brass terminal with porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 30 providing & fixing of isi marked ( is :3854 ) 16 amp. combined flush type non modular socket and switch set with indicator and fuse set as per pwd specification for electrical works, made out from industrial grade polycarbonate or fire resistant abs material, brass terminal with porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 31 providing and fixing of non modular power plug point accessories as per pwd specification for electrical works with 18 swg g i box of size 175 x 100 x 60 mm with earthing terminal / connector on recessed / surface with suitable size phenolic laminated sheet ( is : 2036 1995 ) cover including cost of 16 amp. switch ( is :3854 ) and 3 / 6 pin 16 amp. socket outlet [ as per detailed in respective item in bsr ] , making connection , testing , etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 32 providing & fixing of isi marked ( is:1293 ) 6 amp unbreakable 3 pin plug top with lamp indicator as per pwd specification for electrical works, made out from industrial grade polycarbonate or fire resistant abs material, brass terminal including making connection testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 33 providing & fixing of isi marked ( is:1293 ) 16 amp unbreakable 3 pin plug top with lamp indicator as per pwd specification for electrical works, made out from industrial grade polycarbonate or fire resistant abs material, brass terminal including making connection testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 34 providing & fixing of non modular socket size flush type 120 watt rotary minimum 5 step fan regulator as per pwd specification for electrical works, isi marked ( is:11037 ) made out from industrial grade polycarbonate or fire resistant abs material including making connection testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 35 providing & fixing of isi marked ( is:2268 1994 ) single / multi tone electronic call bell as per pwd specification for electrical works, including making connection testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 36 supply, fixing and testing of following capacity wall mounted stablisers having output voltage variation from 200v to 250v ( + / 5% ) with input voltage variation from 170v to 260v, time delay facility from 2 to 4 minute and high cutoff at 270v complete in all respect e074601 3 kva 37 providing & fixing of ip51 direct or ct operated, 1x240 / 3x240 volts, 50 hz static watt hour meter ( kwh ) as per pwd specification for electrical works, isi marked ( is :13010 2002 ) having resolution 0.1 / 0.01 kwh , accuracy class 1 as per is:13779, led indicators for tamper operation ( reverse & / or earth connection ) , pulsating led indicator for meterology , lcd display, cover plate for body and terminal sealing , push button for all standard parameters, including making connection , testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 10 a to 60 ampere single phase meter. 38 providing & fixing of iso certified company made tp&n 415 v side handle operated double break fuse switch unit in sheet steel enclosure as per pwd specification for electrical works conforming to is / lec 60947 3 : 1999 ( w / o hbc fuses ) including making connections with suitable lugs, testing etc. as required. appropriate type test certificate / oem test report shall be submitted . all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 100 a rating 39 providing & fixing of iso certified company made 240 / 415 v porcelain kitkat fuse ( / hbc type ) as per pwd specification for electrical works conforming to is:2086, 1983 on existing board / sheet including making connections with lugs, testing etc. as required . appropriate type test certificate / oem test report shall be submitted . all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 63 a , 415 v. 40 100 a , 415 v 41 providing & fixing of iso certified company made bus bar chamber housed in sheet metal box as per pwd specification for electrical works confirming to iec 60439 / is 8623 & iec 60529 / is 2147 made out from 1.6 mm thick powder coated crca sheet, degree of protection ip 31 front openable bus bar made out of aluminium or wrought aluminium alloy suitable for 200 amp. capacity , bus bar fixed on porcelain / dmc insulators at approved spacing including making connections etc. as required. appropriate type test certificate / oem test report shall be submitted . all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 300 mm long , 4 strip. 42 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed unarmoured / armoured aluminium cable of 1.1 kv grade as per pwd specification for electrical works in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points ( a ) , ( b ) , ( c ) , mentioned below: ( a ) material : h4 grade aluminium conductor of purity >99.6 % & as per is:1554 p i / is :7098 p – i ( b ) conductor shall have electrolytic aluminium confirming to is 8130, is 3975 1999 for armouring of cables in armoured cable items , is 5831 for sheath, is 10810 ( part 0 to 64 ) for testing procedures. ( c ) oem must have iso 9001 & 14001 certifications for quality assuarance & its own in house nabl lab setup for all testing facilities for cables . appropriate type testcertificate / oem test report shall be submitted . all above as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr. e110110 un armoured 16.0 sq. mm 4 core. 43 un armoured25.0 sq. mm 4 core 44 providing & laying of double wall corrugated pipe confirming to is : 14930 p 1 & 2 with hdpe coupler at 1 mtr. depth below the ground for laying cable including making the trench and back filling , compaction of earth as required ( excavation of earth to be paid extra as required. ) of following outer dia. / inner dia as per is:4984:1995. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr .55 / 50 mm. 45 sitc of chemical gel earthing system of dual pipe technology made of with b class g i pipe as per is 1239 ( part 1 ) :2004 of medium duty of following sizes as per points mentioned ( a ) , ( b ) , [ c ) , ( d ) , ( e ) below : ( a ) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, cpri / erda tested with rms capacity of minimum 35 40 ka for withstanding 1 second . ( b ) to ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. the compound shall be tested form nabl acredeated lab for low resistivity ( less than 0.12 ohm meter ) & high conductivity in nature with carbon as a major content as per referance of is 3043 1987, ieee 80 2013 ( clause 14.5d ) , ieee 837 & ier 1956 with latest amendemnts ( c ) heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height 250 to 300 mm. ( d ) testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. ( e ) self certificate for confirming above standards from oem is mandatory. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . e140510 with pipe in pipe technology ( outer pipe dia. / inner pipe dia. ) minimum 100 mm dia borewell gi pipe 2000 mm long, 50 / 25mm, terminal 40mm x 6 mm gi strip. 46 supply & laying following size earth strip in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, jointing shall be done by overlapping and with 2 set of brass ( for custrip ) / gi ( for gi strip ) nut bolt & spring washer spaced at 50cm making connection etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 25mm x 3mm g.i. ( hot dipped ) strip 47 supply & laying following size earth wire in horizontal or verticalrun in ground / surface / recess including riveting, soldering, saddles, making connection with gi / cu thimble etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 8 swg copper wire. 48 providing & fixing of iso certified company made bee star rated copper wounded double ball bearing capacitor start, aluminium body & metallic blade ceiling fan as per pwd specification for electrical works, conform to all the performance requirements laid down in is:374 2019 including all amendments, as applicable ; & carry bis licensing ( i.e. isi marking ) or quality certification such as iso 9001 or above. with down rod up to 30 cm with secondary support. 1200 mm sweep bee 2 star rated ( service value >=4.5 to < 5 ) . 49 providing & fixing of of double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor , making connections, testing etc. as required. oem shall be an iso certified company. appropriate oem test certificate shall be submitted by contractor. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 225 mm sweep 50 providing & fixing of heavy duty capacitor start, copper wound double ball bearing 900 / 1400 rpm single phase exhaust fan as per pwd specification for electrical works, conforming to is:2312 isi marked in existing opening including making connections testing etc. as required. oem shall be an iso certified company. appropriate oem test certificate shall be submitted by contractor. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 300 mm sweep ( 900 / 1400 rpm ) . 51 providing & fixing of capacitor start, copper wound, metal body, metal blade three speed wall mounting fan of following sweep with the help of anchor bolts including making connection testing etc. as required. oem shall be an iso certified company. appropriate oem test certificate shall be submitted by contractor. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 400 mm sweep ( oscillating type ) . 52 providing & fixing of fluorscent tube rod in existing fixtures as required complete in all respect. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . flourscent powder coated. 36 / 40 watts. 53 providing & fixing of energy efficient / energy saving ip 20 led direct retrofit bulb in existing holder or fixture as required with system lumen efficacy =100 lm / watt output , pf 0.95 , cri >70, minimum life time of minimum 25000 burning hours with , 70% of intial lumen maintaned till life ends , cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be of bis standard and trade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing on housing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 / lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge . foe additional technical parameters of product / work, refer annexure a attacheded with this bsr. 9 watt 54 15 watt 55 rewinding of ceiling fan motor ( starting and running winding ) including all necessary material. the motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enamelled wire with e class insulation material and making connections etc. as required. replacement of material or components shall be use as per guidelines of oem of original product. all the scrap material should be retained by the contractor. ( new model ceiling fan ) . 900 / 1200 mm sweep ( new model ceiling fan ) 56 labour charges for removing and refixing of ceiling fan / exaust fan from site 57 charges for oiling, overhauling of ceiling fan, table fan, pedestal fan irrespect to the size of fan including removing, refixing of fan from site and testing etc. as required. fans with removing & refixing at suitable location. 58 providing and replacement of ball bearing of ceiling / exhaust fan and refixing the same at suitable location as requiredand as per oem recommendations. replacement of material or components shall be use as per guidelines of oem of original product. all the scrap material should be retained by the contractor. 59 p & replacement of cover / bearing seat of ceiling / exhaust fan. replacement of material or components shall be use as per guidelines of oem of original product. all the scrap material should be retained by the contractor. 60 p & f aluminium blades ( a set of 3 blades ) duly painted and well finished 900 / 1200 mm. the material of the fan blade shall be of designation 31500b with condition hx6 aluminium alloy sheet confirming to is 737 / 2008. 61 servicing and overhauling of 20 sweep desert cooler including oiling, greasing, painting of tank from inside with rubber paint after properly desmantling each assembly and refixing the same as required. 62 painting of desert cooler with two coats of rubber paint inside of water tank and two coat of synthetic enamelled paint on both side of cooler body, fan body, grills etc.after cleaning with sand paper, complete in all respect as required. 63 replacement of cooler pads ( heavy ) set of 3 no. of size 25 x 27 64 p & f aluminiun blade for 20 desert cooler fan as required. 65 p & f of isi marked vertical pump suitable for 20 desert cooler including making connection testing etc. as required. isi marked vertical pump. 66 p & f fan motor suitable for 20 desert cooler including making connection testing etc. as required. with copper winding motor isi marked. 67 rewinding of heavy duty exhaust fan motor including all necessary material, the motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size supernamelled wire with e class insulation material and making connections etc. as required. replacement of material or components shall be use as per guidelines of oem of original product. all the scrap material should be retained by the contractor. 300 / 380 mm sweep. 68 rewinding of motor of desert cooler pump with super enamelled copper wire, e class insulation material including removing, refixing, testing etc. as required. replacement of material or components shall be use as per guidelines of oem of original product. all the scrap material should be retained by the contractor. 69 rewinding of motor of desert cooler fan with super enamelled copper wire, e class insulation material including removing, refixing, testing etc. as required. replacement of material or components shall be use as per guidelines of oem of original product. all the scrap material should be retained by thecontractor. 70 supplying and charging of fresh refrigerant and testing of performance of air conditioner / fridge / water cooler of following capacity including capillary and strainer / filter. 1.5 tr window / split a.c. 71 2.0 tr window / split a.c. 72 25 / 50 / 40 / 80 ltr. water cooler 73 replacement of defective compressor by company repaired compressor as per oem recommendations of following gadgets including testing etc. as required. replacement of material or components shall be use as per guidelines of oem of original product. all the scrap material should be retained by the contractor. 1.5 tr a.c. 74 2.0 tr a.c. 75 25 / 50 / 40 / 80 ltr. water cooler 76 p & replacement of condensing / cooling coil of copper fins for following capacity a.c. / water cooler / fridge as required. replacement of material or components shall be use as per guidelines of oem of original product. all the scrap material should be retained by the contractor. 1.5 tr a.c. 77 2.0 tr a.c. 78 25 / 50 / 40 / 80 ltr. water cooler 79 servicing of 1.0 / 1.5 / 2.0 tr capacity split / window type air conditioner. 80 p & replacement of overload protection of a.c. / water cooler as required. replacement of material or components shall be use as per guidelines of oem of original product. all the scrap material should be retained by the contractor. 81 p & replacement of thermostat of a.c. / water cooler / fridge as required. replacement of material or components shall be use as per guidelines of oem of original product. all the scrap material should be retained by the contractor. 82 p & replacement of selector switch of 1.0 / 1.5 / 2.0 tr a.c fan as required. replacement of material or components shall be use as per guidelines of oem of original product. all the scrap material should be retained by the contractor. 83 p & replacement of starting relay of a.c / water cooler / fridge compressor as required. replacement of material or components shall be use as per guidelines of oem of original product. all the scrap material should be retained by the contractor. 84 s & f of capacitor of 230v / 275v, 50hz rating of plastic casing and terminals lugs or copper wire. starting capacitor.40 60 micro farad. 85 60 80 micro farad. 86 running capacitor 2.5 / 3.15 micro farad. 87 4.0 micro farad 88 6.0 micro farad 89 8.0 micro farad 90 10.0 micro farad 91 providing & fixing of ip20 led surface / recessed / suspended mounting mid power smd type led light fixture made from crca sheet steel housing, high purity / transmisivity uv stabilized non yellowish diffuser for uniform light distribution. high efficiency with 2.5 kv internal / external surge protection bis certified isolated driver having efficiency > 85% , with short & open circuit protection and in compliance to iec standards ( integral with light fixture ) . system lumen efficacy min. 100 lm / watt , thd < 10 % , p.f.=0.95, cri >80 , life time of minimum 50000 burning hours with , 70% of intial lumen maintaned till life ends , cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be of bis standard and trade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing on housing. oem must have its own in house nabl acredeated lab setup for all testing facilities for led fixtures. ( lm79 / lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge . for additional technical parameters of product / work, refer annexure a attacheded with this bsr. recessed mounting 48w led light fixture 2x2 with acrylic / prismatic front cover. 92 gas charging of vrf / vrv system with r410a refrigerant gas. before gas charging system shall be flushed with high purity nitrogen gas to remove carbon content, dirt particles to make sure that there is no chance of mixing any impurity with refrigerant gas. thereafter system shall be tested with nitrogen gas at 1.5 times of working pressure of r410 refrigerant gas to ensure leakproof system. whole system shall be vacuumed up to 500 micron level which ensures the zero moisture content level in piping to ensure better cooling efficiency and long life of the system. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr ....

Department Of Local Bodies - Rajasthan

37370124 tender for electrical work innagar palika laxmangarhbavdee se police thana laxmangarh octagonal pole work octangle pole with led light fixing works at lakshmangarh , road light , providing and laying stranded flexible annealed bare copper conductor xlpe / pvc insulated suitably laid up together overall polyester taped al ( inner sheeted gi steel wire mylar drain wire along with atc drain wireround / steel armoured overall pvc sheathed overall screened core armoured instrumentation cables generally confirming to pas 5308 part 2 2009 , providing & laying xlpe insulated / p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor unarmoured of is:7098 i / 1554 1 approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second class bricks covering, refillingearth, compaction of earth, making necessary connection, testing etc. as required of size. , core metre 25x3.5c , suitable for 15 kw load ( three phase ) including contactor, mcb, cable glands, terminal block and locking arrangement each , supply and erection of octagonal pole of following length and dimension as per table 3 with base plate on the cement concrete foundation of m 15 / m 20 grade ( 1:1.5:3 ) with the help of anchor bolts of grade 6.8 ( is 1367 p iii ) . the pole shall be made of s 355jo grade steel sheet , folded lengthwise to obtained octagonalshape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with is 2629. the pole shall have a weatherproof flush door and locking arrangements. the complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning58.18.3 9 mtr. each 23220.00 18576.00 , plate earthling as per is:3043 withearth plate of size 300mm x 300 mm x 1.0mm by embodying 3 to 4 mtr. below the ground level with 25 mm dia. g.i. ‘b’ class watering pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and c.c. finished chamber covered with hinged type with locking arrangement c.i. cover, c.i frame of size 300mm x 300mm complete with alternate layers of salt and coke / charcoal, testing of earth resistance as required. set , s & laying following size earth wire / strip in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection etc. as required. , 58.19 supply, erection and fixing of hot dipped galvanised overhang ( 60 x 3.25 mm ) with cap ( 250 x 137.9 x 4.05 mm ) over the existing poles58.19.1 single arm overhang each 1382.00 , reinforcement for r.c.c. work at all levels including straightening, cutting, bending, placing in position and binding all complete. , 46.1 p&f 240 / 415 v mcb of breaking capacity not less than 10 ka ( b / c / d tripping characteristic ) isi marked is 8828 ( 1996 ) ] / conforming to iec 60898 in existing board / sheets including making connections with lugs, testing etc. as required. , 75 mm dia hdpe pipe pe 100 pn6 for potable water as per is 4984 metre , sitc of cutting back up surface up to 2 mtr. depth by digging by bogie including all layers of crust for laying pipe line etc. and making good to original condition ( excluding cost bitumen ) metre , providing and laying un reinforced, dowel jointed, plain cementconcrete mix in pavement over a prepared sub base with 43 gradecement, coarse and fine aggregate conforming to is: 383, maximumsize of coarse aggregate not exceeding 25 mm, mixed in a batchingand mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separationmembrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to linesand grades complete as per drawing and as per clause 602, 112 ofmort&h specification including all material, labour, machinery, lighting, guarding and maintenance of diversion , p / f ip 65 / ip 66 protected street light luminaries on existing bracket. fixture made from powder coated single piece pressure die cast aluminum housing with heat dissipation fins on housing with high power leds .diffuser / glass cover for ensuring ip 65 protection for lamp and control gear compartment, system lumen output of 100 lum / watt high power led. integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to iec standards. system life of 50000burning hours with 70 % of initial lumens maintained. fixture shall be in ce compliance....

Military Engineer Services - Rajasthan

37255521 welcome maintenance for offrs qtrs under age b / r ii under ge ( n ) bikaner. 1 m&l preparingof old decorated surfaces of walland applying one coat of distemper oil emuision complete all as specified and as directed by engr in charge. 2 m&l preparingof old decorated surfaces of walland applying two coat of distemper oil emuision complete all as specified and as directed by engr in charge. 3 m&l preparing surfaces of plaster or unplaster old surface of wall and applying one coat of white wash complete all as specified and as directed by engr in charge. 4 m&l preparing surfaces of plaster or unplaster old surface of wall and applying two coat of white wash complete all as specified and as directed by engr in charge. 5 m&l preparing surfaces of plaster or unplaster old surface of wall and applying one coat of white wash on ceiling complete all as specified and as directed by engr in charge. 6 m&l preparing surfaces of plaster or unplaster old surface of wall and applying two coat of white wash on ceiling complete all as specified and as directed by engr in charge. 7 m&l preparing old surfaces of wall and applying one coats of plastic emulsion paint complete all as specified and as directed by engr in charge. 8 m&l preparingold surfaces of ceiingand applying one coats of plastic emulsion paint complete all as specified and as directed by engr in charge. 9 m&l preparing old surface of wood of any desc over 10cm width or girth and applying two coats of synthetic enamel paint .over pink primer complete all as specified and as directed by engr in charge. 10 m&l preparing new surface of steel of any desc over 10cm width or girth and applying two coats of synthetic enamel paint over red oxide complete all as specified and as directed by engr in charge. 11 m&l preparing the old painted wooden surfaces of any description over 10 cm width or girthand applying one coat of synthetic enamel paint.complete all as specified and as directed by engr in charge. 12 m&l preparing new surface of steel of any desc over 10cm width or girth and applying one coat of synthetic enamel paint over red oxide complete all as specified and as directed by engr in charge. 13 m&l complete removal of existing treatment and applying a thin layer of putty on wall surfaces complete all as specified and as directed by engr in charge. 14 m&l preparing new surface of old or new incl removal of old treatment ans applying a thin layerof plaster of paries to give a uniform finish as approved by engr in charge 15 m&l demolition of cement conc. in any description and incl any position not otherwise specially provided complete all as specified and directed 16 m&l dismanting floor, hearth or wall tiling including cement mortar bedding and removal of rubbish out of the premises complete all as specified and as directed by engr in charge. 17 hacking out old broken glass ( any thickness, size, quality or description ) fromwooden frame or stone concrete or brick surrounds glazed with putty or fixed with beads.complete all as specified and as directed by engr in charge. 18 dismantlingpipes of any desc fixed to wall or laid under floor complete all as specified and as directed by engr in charge. 19 dismantling cast iron pipes of any desc fixed to wall or laid under floor complete all as specified and as directed by engr in charge. 20 taking down cement plaster on brick or stone walls, including raking out joints, hacking for key, scrubbing down with water etc. 21 taking up or down steel tubing 15 mm diaand connections and stacking neatly for offering credit complete all as specified and as directed by engr in charge. 22 all as per item n 21 above, but 20 mm dia. complete all as specified and as directed by engr in charge. 23 taking down chowkhats or frameswith shutters ( without taking off shutters from the frames ) of size n. exc 1.5 sqm each complete all as specified and as directed by engineer in charge. 24 taking down chowkhats or frameswith shutters ( without taking off shutters from the frames ) of size exc 1.5 sqm but not exc 4.0 sqm each complete all as specified and as directed by engineer in charge. 25 taking down shutters of any description, areaexceeding 1.00 sqm and n.exc 2.00 sqm eachcomplete all as specified and as directed by engineer in charge. 26 m&l for welding in repairs n.exc 2.5 cm in length and not exceeding 6mm thick of metal complete all as specified and directed by engineer in charge. 27 s&f 1.25 mm thick pressed steel frames of size 125mm x 60mm for single doorsincluding necessary fixing lugs, hinges, lock strike plate, etc complete all as per is provns.complete all as specified and as directed by engr in charge. 28 s&f 1.25 mm thick pressed steel frames of size 105mm x 60mm for single doorsincluding necessary fixing lugs, hinges, lock strike plate, etc complete all as per is provns.complete all as specified and as directed by engr in charge. 29 s&f second classhard wood plain, framed, panelled shutters 35mm thick, ( any number of panels ) with panels of timber flat on both sides ( feather edged ) or of veneered partcile board medium density wood particle board with commercial faces venners supplied and fixed to chowkats.complete all as specified and as directed by engr in charge. 30 s&f second class hard wood, glazed and skelleton shutters 35mm thick, open rebated and prepared to receive glass, gauze, etcwithout sash bar, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing gauze etc, size of members as directedsupplied and fitted to chowkats complete all as specified and as directed by engr in charge. 31 m&l for 25 mm thick flush shutters for cupboards solid core construction, with block board core, and ply wood face panels, both faces covered with decorative face veneer with lipping to matchcomplete all as specified and as directed by engineer in charge. 32 s&f solid pvc door frame of size 50 mm x 47 mm made out of 5 mm plain colour pvc sheet reinforced with m.s. square tube suppling & fixing in opening all as specified and as directd. 33 s&f factory made solidpanel pvc door shutter 30mm thick ( style ) consisting of framemade out of ms tubes for top and bttom rails. ms frame shall be covered with heat moulded plain colour pvc c channel having a pvc sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colourpvc sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail, panneling of plain color pvc sheetto be fitted in the ms frame welded / sealed to the stiles &rails with suitable pvc sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site all as specfied and as directed. 34 s&f steel window / ventilators pressed steelframed ( box type ) factory made glaged and guaged with side hung shutters including pintolhinges, steel handles, steel peg stay and all locking arrangement complete with glazing bars dovetailed or welded incl a prov of cooler / ac opening with shutter including one shop coat of red oxide primer complete all specified.note :i ) he window shall be fabricated as per drg no cebz / 888r & 889 sheet 1 to 4. ii ) ms fillets, glazing, wire gauge shall be measured and paid separately. 35 s&f framed work such as grills , framed guard bars barred iron doors ;ladders framed balusters railings and similar work conforming to fe 410 0or fe 310 0 complete all as specified and as directed by engr in charge. 36 s&f stainless steel wire cloth o.36mm nominal dia of wire and average width of aperature 1.40mm and fixed with stainless steel wire staples.complete all as specified and as directed by engr in charge. 37 s&f stainless steel wire cloth o.36mm nominal dia of wire and average width of aperature 1.40mm and fixed in repairwith stainless steel wire staples.complete all as specified and as directed by engr in charge. 38 m&l for second classhard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the soild, rounded or chamfered, put together with glue pinned at joints.complete all as specified and as directed by engr in charge. 39 m&l second classhard wood, in scantling wrought, in timber fixed complete all as specified and as directed by engr in charge. 40 teakwood beading 20x60mm half round complete supplied and fixed complete all as specified and as directed by engr in charge. 41 s&f 18 / 19 mmplywood, grade 1 ( with bwr resistant / termite proof ) with fixed with screws to timber frame work as in cup boards / cabinets etc complete all as specified and as directed by engr in charge. ( make : century / kitply / or other app by ge ) 42 m&l for water proofing block boards 18 / 19 mm , grade 2 exterior quality grade , commercial type fixed with screws to timber frame work. complete all as specified and as directed by engr in charge. 43 m&l for 0.9 mm thick decorative choice of laminates type i of surface finishwhitestuck with importedadhesive on sides of board as directed by eng in charge . ( make corby, or euro ) 44 m&l prelaminated partical board 19 / 20mm medium density , prelaminated with one side with decorative choicelaqmination and other side balancingwith white laminationfixed with screws as in shelves to kitchen almirah and cub board fixed in repair.complete all as specified and as directed by engr in charge. 45 s&f 12mm thick plywwod grade bwr , type bb , fixed with screws to timber frame work.complete all as specified and as directed by engr in charge. 46 s&f 6mm thick plywwod grade bwr , type bb , fixed with screws to timber frame work.complete all as specified and as directed by engr in charge. 47 m&l for 0.9 mm thick decorative choice of laminationtype 1 of surface finish , colour and pattern as approved adhesive as per manufacturers instructions complete all as specified and as directed by engr in charge. 48 m&l for 1.50 mm thick pvc laminated decorative impressionchoice of laminationtype 1 of surface finish , colour and pattern as approved adhesive as per manufacturers instructions ( corby / duco ) . 49 s&f stain less steel catcherof superior quality complete all as specified and as directed by engr in charge. 50 s&f stain less steel pivoted type hingesof superior quality complete all as specified and as directed by engr in charge. 51 s&f 75mm long brass handle of desired finish with screws as approved by engg in charge. 52 s&f 35mm long mortice lockcomplete all as specified and as directed by engr in charge. ( make :godrej / harrison ) 53 s&f 75mm long brass tower bolt of desired finish with screws as approved by engg in charge. 54 s&f drawer side channel of std size and incl of rooler for moving drawer, mild steel bright finish, or electrogalavanised width of flap 30mm & length 60 mm all as specified. 55 s&f stainless steel fancy type, bright finish handles fixed with screw, of 125mm size all as specified. 56 s&f stainless steel multipurpose bracket in wooden / partitions for storing rations types made of 4mm dia stainless steel rods, fixed in side partition etccomplete.make: usha shriram enpt or equivalent ) . 57 s&f stainless steel luddel craddle hanging stand for cutlery all as specified and directed dy engr in charge.make: usha shriram enpt pvt ltd. 58 s&f stainless steelzero crank hinges fancy type ( with euro concealed hinges make: avis gold or equivalent ) fixed to shutter in cub board of std size and shape all asdirected dy engr in charge. 59 s&f 7s&f sinks made of stainless steel lmmthickkitchenorlaboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm including fixing contilever brackets and connecting union to pipe complete all as specified and as directed by engr in charge. 60 m&l for recessed type stain less steelhandle for cup boards size 150 mm long complete all as specified and as directed by engr in charge. 61 m&l for roller ( pvc / stain less steel ) suiltable for sliding shutters . as app by eng in charge 62 pvc toilet cabinet with shelves and shutters fixed with looking mirror of size 600 x 450 mm complete all as specified and as directed by engr in charge. ( make : commander or equivalent ) 63 s&f continous ( piano ) hinges 30mm wide mild steel bright hinges 30 mm with flap, ms bright finished or electrogalvanised complete all as specified and as directed by engr in charge. 64 hasp and staple 100mm aluminium anodised, safety type, with mild steel hinges pin including bolt to hinge plate and fixed with screws complete all as specified and as directed by engr in charge. 65 s&f mild steel peg set stay 300 mm with and incl screws and bolts complete all as specified and as directed by engr in charge. 66 butt hings, 100 mm long, extructed aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type c 21.complete all as specified and as directed by engr in charge. 67 s&f butt hings, 100 mm long, extructedisi marked complete all as specified and directed by engr in chargefixed complete all as specified and as directed by engr in charge. 68 s&f extruded aluminium alloy handles, 100 mm long, fabricated type anodised complete all as specified and as directed by engr in charge. 69 s&f aluminium, anodised , 100 mm long, barrel tower bolts of extruded section and fixed complete all as specified and as directed by engr in charge. 70 s&f extruded aluminium alloy handles, 150 mm long, fabricated type anodised complete all as specified and as directed by engr in charge. 71 s&f aluminium, anodised , 150 mm long, barrel tower bolts of extruded section and fixed complete all as specified and as directed by engr in charge. 72 supply and fix floor door stopper of aluminium alloy body, overall length of cover plate 140 mm and tongue anodised with hard drawn steel sring fixed in floor complete all as specified and as directed by engr in charge. 73 s&f aluminium alloy, anodised, slidding door bolt300mm long, with hasp staple ( bolt type ) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified and as directed by engr in charge. 74 s&f mild steel, 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete fixed in repair complete all as specified and as directed by engr in charge. 75 s&f figured glass, pin head type, 4mm thick and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and as directed by engr in charge. 76 s&f 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square not execeeding 0.5 sqm in each pane for metal frames complete all as specified. 77 s&f anodised aluminium with powder coating frame for doors, windows , ventilators with one or more rebates includirg joining cleat for fixing etc. complete all as specified and as directed. 78 s&f anodised aluminium frame for doors, windows , ventilators with one or more rebates includirg joining cleat for fixing etc. complete all as specified and as directed. 79 s&f sheet glass, ordinary quality 5.5 mm thick for aluminium door , window and vent.and glazing in square n exc 0.5 sq.m in each pane complete all as specified. 80 s&f neoprene / epdm rubber gasket for fixing sheet glass complete all as specified. 81 m & l pcc25 mm thick 1:2:4 type b0 ( 12.50 mm graded aggregate ) in any position in ground floor / roof complete all as specified and as directed by engr in charge. 82 m & l pcc75 mm thick 1:3:6 type b0 ( 12.50 mm graded aggregate ) in any position in ground floor / roof finishing cement concrete surface without using extra cement complete all as specified and as directed by engr in charge. 83 m & l pcc1:2:4 type b1 ( 20 mm graded aggregate ) as in hold fast blocks rungs etc icluding necessary form work complete all as per specified and directed ny engr in charge 84 m & l pcc 1:3:6 type c0 ( 12.50 mm graded aggregate ) as in filling in pressed steel frames complete all as specified and as directed by engr in charge. 85 m and l for coloured non skid ceramic tiles exceeding 0.11 sqm but not exceeding 0.18 sqm 7 to 8mm thick in floorsset and jointed in neat cement slurry and pointed incoloured cement to match the floorlaid over 15mm thick screed in cement mortar 1:6.complete all as specified and as directed by engr in charge. 86 m&l glazed ceremic tiles white450x300mmx7mm thickcoloured, set and jointed in neat cement slurry and pointed in white cement or coloured to match colour matching with floortiles as on vertical surfaces laid over 10mm thick cement screed in 1:4.complete all as specified and as directed by engr in charge. 87 m&l chequered cement concrete tiles 25 cm x 25 cmx25mm thick with grey cement and no pigment set jointed and pointed in neat cement slurry in floors including 15 mm thick screed bed in cement and sand mortar 1:4 complete all as specified 88 m&l for vitrified tiles not exceeding 0.36 sqm 10 mm thick in floors set and jointed in neat cement slurry and pointed in neat cement s;urry in floors including 15 mm thick screed bed in cement and sand mortar 1:4 complete all as specified 89 m&l for vitrified tiles not exceeding 0.36 sqm 10 mm thick in floors set and jointed in neat cement slurry and pointed in neat cement s;urry in floors including 15 mm thick screed bed in cement and sand mortar 1:4 complete all as specified but in vertical surface. 90 m and l for 20mm thick granitemachine cutslab table rubbed and polished graniteas on cooking platforms incl. pointing in white cement 1:2using marble dustwith admixture of pigmentto match with marble shadelaid over 20mm thick cement screed in cement mortar 1:6.complete all as specified and as directed by engr in charge. 91 rendering 10 mm thick in cm 1:6 on other than fair faces of brick work or concrete surfacesfinished fair and even complete all as specified and as directed by engr in charge. 92 rendering 15 mm thick in cm 1:4 on fair faces of brick work or concrete surfacesfinished fair and even complete all as specified and as directed by engr in charge. 93 rendering 5mm thick on fair faces ofconc. surfaces in cement mortar 1:3, even and smooth w / o using extra cement as on ceiling.complete all as specified and as directed by engr in charge. 94 s&f tubes, medium grade galvanised, 15 mm borewith all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed by engr in charge. 95 s&f tubes, medium grade galvanised, 20 mm borewith all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed by engr in charge. 96 s&f aluminium sheeting 0.56 mm thick alloy 31000 h4 in ridges, hips, valley gutter drip and straight flashing ( length and girth as fixed ) complete all as specified and as directed by engr in charge. 97 s&f mild steel work as in hold fasts, clamps, bands, straps etc conforming to fe 410 0 complete all as specified and as directed by engr in charge. 98 s&f sinks with drainage board made of stainless steel 1mm thick kitchen or laboutery with plugs, washers and wastes including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915 mm x 460mm bowl size 410 mm 330 mm x 160mm complete all as specified and as directed by engr in charge. 99 s&f stainless steel plate rack, tubular type, with fixing arrangement900mm x 900 mm size all as directed and as approved by engr in charge. 100 s & f glass corner of size 300mmx300mm with5.5 mm thick glass andsteelness steel clip and steelness steel railing allround the shelfcomplete all as specified and directed by engineer in charge . 101 s&f 600x450mm bevelled edge mirror of selected quality glass mounted on 6mm th ac building board or commercial ply complete all as specified and as directed by engr in charge. 102 s&f 5mm thick looking mirror of selected quality with and including stainless steel spacers any size as approved by engrbevelled edge mirror of selected quality glass mounted on 6mm th ac building board or commercial ply complete all as specified and as directed by engr in charge. 103 s&f pvc ( swr ) pipes 75 mm bore, single socketed, in any length with rubber ring jointed fixed to walls complete all as specified and as directed by engr in charge. 104 s&f pvc ( swr ) pipes 110mm bore, single socketed, in any length with rubber ring jointed fixed to walls.complete all as specified and as directed by engr in charge. 105 s&f pvc ( swr ) branch piece, single ( single y ) equal or unequal, 75mmbore.complete all as specified and as directed by engr in charge. 106 s&f pvc ( swr ) vent cowl 75 mm complete all as specified and as directed by engr in charge. 107 s&f pvc ( swr ) floor trap 75 mm, plain with grating including jointing with solvent cement complete all as specified and as directed by engr in charge. 108 s&f pvc ( swr ) branch piece, single ( single y ) equal or unequal 110mmbore.complete all as specified and as directed by engr in charge. 109 s&f pvc ( swr ) bends any radius 75mm bore complete all as specified and as directed by engr in charge. 110 s&f pvc ( swr ) bends any radius 110mm bore complete all as specified and as directed by engr in charge. 111 s&f pvc ( swr ) gully trap 125 / 110 mm setting and jointing with solvent cement complete all as specified and as directed by engr in charge. 112 s&f in repair stack clamp out of 40mm x3mm flat iron stays with rubber gasket covering including bolt and nuts, spacer and securing ends of stays to walls or roof for 50mm bore piece complete all as specified and as directed by engr in charge. 113 s&f in repair stack clamp out of 40mm x3mm flat iron stays with rubber gasket covering including bolt and nuts, spacer and securing ends of stays to walls or roof for 100mm bore piece complete all as specified and as directed by engr in charge. 114 disconnecting existing tanks, setting aside ( or lowering if required ) for repairs cleaning etc andhoisting if required reconnecting and refixing in position after cleaning and removing all scale and dirtetc from tanks and from mouths of circulating pipes etc complete ( capacity of tanksexc 250 ltr and n exc 500 ltrs ) complete all as specified and as directed by engr in charge. 115 s&f rotational moulded double layer ( isi marked of app make ) polythene water storage tank ( cylindrical vertical with closed top ) hoisted and fixed in position of 500 ltrs including dismantling existing.complete all as specified and as directed by engr in charge. 116 s&f ball valve high pressure of ptmt with epoxy coated almn rod and high density plastic ball screwed for iron pipe and fixedfixed in repair.of 20mm complete all as specified and as directed by engr in charge.make : prayag or equivalent. 117 s&f brass cp wall mixer non telephonic for mixing hot and cold water screwed down for iron pipe 15mm bore.complete all as specified and as directed by engr in charge. ( make : parryware or hindware or equivalent ) . 118 s&f brass cp whb mixer non telephonic for mixing hot and cold water screwed down for iron pipe 15mm bore complete all as specifie and as directed by engr in charge . ( make : parryware or hindware or equivalent ) . 119 s&f vitreous china wash down water closet pan with fixing bolts, trap ( pedestal pattern ) , white, ( excludingflushing cistern and flush pipe ) complete fixed in repairs complete all as specified and as directed by engr in charge. 120 supply and fix vitreous chinawash hand basin flat back size 550 x 400mm including cutting for and pinning in ends of brackets or erecting stand etc complete fixed in repairs complete all as specified and as directed by engr in charge. 121 s & f pvc valveless ( syphon internal fitting ) of pvc low levelaction type flushing cistern, 10 ltr capacity low level , whitewith inlet, ball valve, float and handle including brackets fixed in repairs complete all as specified and as directed by engr in charge. 122 s & f pvc valveless syphonic action type flushing cistern, 10 ltr capacity low level , whitewith inlet, ball valve, float and handle including brackets fixed in repairs.complete all as specified and as directed by engr in charge. 123 s&f pvc connections 15 mm size with ptmt nuts of length 450 mm complete all as specified and as directed by engr in charge. 124 s&f stainless steel tubular towel rail, 200 mm dia d type 60cm long between flanges complete all as specified and as directed by engr in charge. 125 s&f bib tap 15 mm dia, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwedfor iron pipeand fixed in repairs complete all as specified and as directed by engr in charge. ( make : parryware or hindware or equivalent ) 126 s&f bib tap 15 mm dia, long body fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwedfor iron pipeand fixed in repairs complete all as specified and as directed by engr in charge. ( make : parryware or hindware or equivalent ) 127 s&f stop valve, 15 mm dia, fancy type, chromium plated, cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repairs complete all as specified and as directed by engr in charge. 128 s&f stop valve, 15 mm dia, concealed stop valvefancy type, chromium plated, cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repairs complete all as specified and as directed by engr in charge. 129 s&f pillar taps, 15mm dia, fancy type, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, long screwed shanks and fly nuts, screwed for iron pipe and fixed in repairs.complete all as specified and as directed by engr in charge.make: jaquar or equivalent 130 s&f brass chromium plated shower rose 125 mm size including fixing to steel pipe or union fixed in repairs complete all as specified and as directed by engr in charge.make: jaquar or equivalent 131 sf brass chromium plated shower arm 15 mm 195 mm long with bend 45 degreemm size including fixing to steel pipe or union fixed in repairs complete all as specified and as directed by engr in charge.make: jaquar or equivalent 132 s&f sheet glass shelf assembly in repair , oconsisting of 5.5 mm thick sheet glass shelf 12 cm wide chromium plated bracket guard and railing 60 cm long complete all as specified. 133 s&f plastic water closet seat, white, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed by engr in charge. 134 s&f cp health faucetfixed type suitable for ewcs with 1, 5 mtr stainless steel tube complete all as specified and directed by engineer in charge make : jaquar, prayag 135 s&f cp toilet paper holder fancy type complete all as specified and directed by engineer in charge.make: jaquar or equivalent 136 s&f angle valve cast copper alloy fancy type cp with long shank and cup and screwed for iron pipefixed in repair complete all as specified and as directed by engr in charge.make: jaquar or equivalent 137 s&f waste pipe 32mm for whb with coupling fixed in repairs complete all as specified and as directed by engr in charge. 138 m&l for along the wall below concrete or masonry using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and as directed by engr in charge. 139 m&l for treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 ( 1 cement: 2 coarse sand ) to match the existing floors complete all as specified and as directed by engr in charge. 140 s&f grating doom 125 mm dia with waste hole of ptmt ( minimum weight 40 gms ) complete all as specified and as directed by engr in charge. 141 s&f chromium plated soap dish complete all as specified and directed by engineer in charge. 142 s&f aluminium snake bead with bush duly fitted with screws with length equal to door width as specified and directed by engr in charge 143 m&l for repairingof rolling shutters making functional by providing greasing oiling , welding etc.including taking down rolling shutters or hood if required complete all as specified and as directed. 144 s&f safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and as directed by engr in charge. 145 s&f ball bearing for rolling shutters.complete all as specified and as directed by engr in charge. 146 m&l for 25mm to 30mm thick plaster of paris ( pop ) ( gypsum anyhydrous ) raised moulding to flat surface of ceiling including preparation of surfaces all as directed.complete all as specified and as directed by engr in charge. 147 m&l for green sheet pvc of best quality to cover the surface where required complete all as specified and as directed. 148 s&f water closet pedestral pattern white or coloured ( as approved by engr in charge ) make :cera cat no.s1013113 ( cristy single piece suite p or s trap incl seat cover ) or equivalent in hindware , jaquar, parryware ) complete all as specified and as directed. 149 s&f in aluminium composite panel of any colour of having thickness of approx 3 4mm thick which are used in aluminium doors / partitions of all as specified and as directed. 150 s&f in pre laminated pvc boards of heat and fire resistant , non toxic , anti chemicaland corrosion resistant, termite proof and resistant to fungal attacks used in kitdhen cabinets of any finish complete all as specified and as directed. 151 m&l washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 ( 1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 kg of cement per square metre, top layer 15mm cement plaster 1:1 / 2:2 ( 1 cement: 1 / 2 coarse sand : 2 stone chipping 10mm nominal size ) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified ( paymentfor providing grooves shall be made separately ) . 152 s&f 10.00 mm thick gypsum boards as in ceiling as per approved desidg including recessing for provision of ceiling lights , moisture resistant , incl intermediate , perimeter channel ceiling channel , alon nuts and bolts connecting plates gypsum boards , dry wall screws soffits cleats , ceiling section, rowel plugs fixtures and screws complete all as spfd and as shown in sketch and applying twwo coats of emulsion paint over a coat primer on exposed surfaces.design of ceiling board as app by engr in charge. ( note: no extra payment shall be claimed from contractor for designs to ceiling falls etc ad shall be measured in plan only ) 153 m&l for 1.5mm thick self adhesive waterproofing membrane consisting of self adhesive sbs ( styrene butadiene styrene ) modified / bitumen compound covered on the top side with high density cross laminated polyethylene film and on the underside with an easy to peel silicon film all as per manufacturer’s instructions having minimum overlaps 50mm on sides and 100mm on ends, provided with & including suitable bitumen primer @ 0.30 litre per sqm as recommended by membrane manufacturer after cleaning the roof surface / sunken floor from all loose, dust, dirt, foreign material and particularly oil and grease marks, complete all as specified and as directed.make : m / s texsa india ltd / m / s pidilite industries ltd / m / s sika india pvt ltd / m / s stp limitednote : the net area of waterproofing treatment shall be measured and paid for without any extra allowance for side & end laps for membrane and this aspect shall be deemed included in the quoted rates. 154 taking down carefully ( aluminium ) point wiring complete of any type ( batten / surface conduit or concealed ) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper / white washing / colour washing to match with the existing surface complete all as spcified and directed. 155 taking down submain wiring aluminium / copper of any size including earth continuity condutor on teak wood or conduit and removing from site and making good the disturbed surface of wall etc complete all as specified and directed. 156 taking down old u / s existingdb tpn 4 way anddb spn 12 way including mcb / mccb of any capacity and any size and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed. 157 m & l for point wiring with and including single core frlsh pvc insulated and unsheathed stranded copper conductor cable of size 1.5 sqmm 1100 volts grade drawn through and including suitable size of pvc concealed conduit with accessorieswithlaminated top cover fixed on ms sunken box for housing of switch, socket, regulator etc complete with and including 1.5 sqmmfrlsh pvc insulated and unsheathed stranded copper conductor cable as earth wire and connected to common earth dolly and making good to the disturbed surfaces of wall, floor, ceiling etc to match with exisiting surface complete all as specified and as directed by engr in charge for the following : ( a ) one light / fan / ex fan / bell / point controlled by one switch. 158 ( b ) one pin 5 amps socket point on the same board with other switches complete 159 ( c ) one 3 pin 5 amps socket on independent board. 160 ( d ) all as per item no 4 above but but one light point controlled by two 02 way switchboard complete and all as directed by engr in charge. 161 ditto all as per item no 157 above but with 4.0 sqmm copper wire for 3 pin socket outlet 20 amp on independent board complete and all as directed by engr in charge. 162 s&f switch piano type, 5 amp, single pole one way, 230 volts, flush type complete all as specified and as directed by engr in charge. 163 s&f switch piano flush type single pole, one way 15 / 20 amps 230 voltscomplete all as specified & directed by engr in charge. 164 m&l socket outlet 3 pin5 amps flush type230 voltscomplete all as specified and directed by engr in charge. 165 m&l for socket outlet 2 in 1, 3 pin, 5 & 15 amps, 230 volts t complete all as specified & directed by engr in charge. 166 s&f ceiling rose, surface backelite , three terminal ac, 230 voltcomplete all as specified. 167 supply and fixing led mirror light fitting , type with high out put diffuser 2 feet, 5watt 220 v ac decorative type with driver holder and led lamp including connecting up with three core flexible copper conductor cable of suitable size complete.havells cat part no enduralinearneobs10wled865spcwh / wipro cat part no ll20 111 xxx 65ne3 / bclsb 10 wh 168 s&f led tube light fitting, 1x 20 22 watts, 230 volt, basic all purpose surface and wall mounted led batten with polycarbonate housing & integrated electronic driver, pre wired and fixed on walls with all fixing accessories such as screws, clips etc and connecting up with two core flexible copper conductor cable of size 24 / 0.20 sqmm complete all as specified and directed by engr in charge. make :philips bn021 led 20s psu cw gr s2 / crompton greaves lddr20 cdl dazzle ray / bajaj bclab 20w 169 s&f single pole and neutralenclosure with a two pin and earth plug and socket complete with one single pole mcb 20 amp complete all as specified and as directed by engineer in charge. 170 supply and fixing fan regulator electronicsocket typefive step controlled 230v ac 50 hz forcomplete all as specified and directed by engr in charge. 171 s&f sheet metal enclosure mcb db, double door, tpn 4 way with 200 amps rated busbar all as specified and as directed. make: hegar / legrand / seimens 172 s & f double door, sheet metal enclosure, powder coated for mcb db spn 12 way fittedwith neutral link, earth bar , din rail and 200 amps rated bus bar 230 volt conforming to is 13032 1991 complete all as specified and as directed by engr in charge. 173 s & f mcb sp, 5 32 amps , 240 volts, breaking capacity 10ka complete all as specified and as dircted by engr in charge. 174 s&f mcb 63amps, c curve tpn, 415 volts, complete all as specified and as directed by engr in charge. 175 supply and fixing bell push, flush type, 5 amp 230v ac 50 hz forcomplete all as specified and directed by engr in charge. 176 supply and fixing buzzer, ding dong ac. 230 volts, single pole complete all as specified and directed by engr in charge. 177 m & l lamp holder, pvc / polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by engr in charge. 178 taking dowen and refixing led light fitting mirror type with high out put diffuser 2 feet, 10 / 5 watt 220 v ac decorative type with driver holder and led lamp including connecting up with three core flexible copper conductor cable of suitable size complete. 179 taking dowen and refixingled tube light fitting, 1x 20 22 watts, 230 volt, basic all purpose surface and wall mounted led batten with polycarbonate housing & integrated electronic driver, pre wired and fixed on walls with all fixing accessories such as screws, clips etc and connecting up with two core flexible copper conductor cable of size 24 / 0.20 sqmm complete all as specified and directed by engr in charge. 180 s&f mccb 100 amps, 4 pole, 415 volts, fixed type breaking capacity 16ka complete all as specified and as directed by engr in charge. 181 s&f mccb 40 amps, 4 pole, 415 volts, fixed type breaking capacity 16ka complete all as specified and as directed by engr in charge. 182 s&f in replacement decorative wall light fittings complete made up of polycarbonate, including withfor 9 w led lamp complete all as specified and directed by engr in charge. make / sample approved by engr in charge : surya / havells / phillips 183 s&f in replacement bad side light fitting with suitable led bulb complete all as specified and directed by engr in charge. sample approved by engr in charge and ge . 184 s & f led light fitting 1x9w / 1x10wbulkhead luminaires including led light driver holder connecting up with three core flexible copper conductor cable of suitable size. 185 s&f switch piano single pole 5 amps, two way, complete all as specified and as directed by engineer in charge 186 supply and fix exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230v, 50 hz, rpm 1200, copper winding of sweep 300m 187 m & l for submain ( single phase ) wiring complete with and including 10 sqmm two single core, ( frlsh ) fire retardant, pvc insulated and unsheathed multistranded copper conductor cable, 1100 volts grade, drawn through existing pvc conduitincluding accessories and fixed on walls and10sqmm, fire retardant, pvc insulated, multistranded copper conductor cable for earthing and connected to common earth dolly complete all as specified and as directed by engr in charge. note : ( i ) two runs of10.0 sqmm pvc insulated wire and one run of 10sqmm wire and one run of pvc conduit shall be measured as one unit length. 188 m & l for submain ( single phase ) wiring complete with and including 4.0 sqmm two single core, ( frlsh ) fire retardant, pvc insulated and unsheathed multistranded copper conductor cable, 1100 volts grade, drawn through pvc conduit of suitable size including accessories and fixed on walls and 4 sqmm, fire retardant, pvc insulated, multistranded copper conductor cable for earthing and connected to common earth dolly complete all as specified and as directed by engr in charge. note : ( i ) two runs of 4.0 sqmm pvc insulated wire and one run of 4 sqmm wire and one run of pvc conduit shall be measured as one unit length. 189 s & f mcb spn, 5 32 amps, 240 volts, breaking capacity 16ka complete all as specified and as dircted by engr in charge. 190 m&l for submain wiringusing 4 runs of single core frls pvc insulated, unsheathed stranded copper conductor cable of size 4runs of 10 sqmm of voltage rating 1100v for three phase & neutral, drawn in and including concealed pvc conduit of dia not less than 25 mm dia with standard acessories, along with two run of frls pvc insulated, unsheathed, stranded copper conductor of size 2x6.0 sqmm as earth continuity conductor all as specified and directed ( note 4 runs of single core frls pvc cable 10sqmm for three phase & neutral with two run of earth conductor as earth and conduit shall be measured as one unit ) ...

Department Of Local Bodies - Rajasthan

37172712 supply and fixing of different electric and cables accessories near maheshwari samaj dharmshala, nathdwara. , sitc of ip 42 and general construction confirming to is:8623 : 1993, wall / free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point ( a ) , ( b ) , ( c ) , ( d ) , ( e ) , ( f ) , ( g ) , ( h ) as below: ( a ) thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided ( b ) complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam / neoprene rubber gasket of not less than 3mm thickness , required hardware , concealed hinged door with key type locking arrangement for equipment / switchgear earthed with 2.5 sq.mm braided copper wire. [ c ) interconnection between bus bar and switchgears / cable shall be rigidly supported and made out by flexible copper wires ( up to 63 amp ) and by solid bus bar ( >63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgear is to be paid extra ) ( d ) wiring between components within switchgear and incoming / outgoing cable shall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. ( e ) all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be ‘point to point’ ( no wire splitting or tee connections ) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. ( f ) floor mounted panel shall be mounted on base frame of ismc channel size 100 x 50 x 5 mm ( to be paid extra ) ( g ) tests: the insulation resistance ( with 1000 v megger ) and high voltage power frequency test ( by applying a voltage of 2.5kv for one minute ) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. the insulation resistance shall not be less than three megaohm. ct secondary current injection test shall also be carried out. ( h ) only outer surface area on all sides shall be measured & panel to be fabricated only from cpri approved fabricator only ( cpri test certificates to be submitted ) all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . , supplying and fixing of aluminium ( iec 60105 iso 209 1, 2 ) / copper ( iec 60028 ) bus bar by means of smc / dmc type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . electrolytic grade aluminium bus bar 6010 grade , providing & fixing of is: 13875 & iec :61326 confirming led digital type ( up to 500 ) v range volt meter / direct ammeter / ct oertated ammeter / frequency meter / kwh meter / multi function meter / power analyzer of class 1 accuracy as per is : 1248 of size 96mm x 96 mm including making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . three phase ammeter with inbuilt selector switch , providing & fixing of bis approved current transformer as per pwd specification for electrical works , isi marked as per is 2705 1992 / conforming to iec 60044 1, with secondary terminal of ct shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required current transformer ring type tape wound / resin cast wound as per is 16227 with, accuracy cl, ct ratio and burden as specified. isf<=5, cu cross section of secondary wire 1.5sqmm ( minimum ) , including all necessary support in existing panel including connection etc. as required . all as per pre approved by engineer in charge.all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr resin cast wound type ct c t class 1, ratio 200 / 5 to 300 / 5, burden 10 va , providing & fixing of ip 51 ( upto 500 ) v range volt meter on existing panel as per pwd specification for electrical works, making connection by pvc insulated copper conductor with pvc sleeves / channel etc. meter shall give true rms measurments, acc. ci 1.0 or better , with field programmable primary & sec. values pt ( vt ) primary upto 2000 kv. field programmable high and low threshold values, meter shall compliance of is 13875 & iec 61236. as required. oem must have bis certificate and & shall have submit nabl / cpri / erda lab test reports before execution &all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . digital , providing & fixing of 110 / 220 v, unibody led indicating lamp iec 60947 with integral circuit, ip 65 above panel & ip 20 terminal block, approx. body dia for panel not less then 20 mm, length min. 50mm, front led cover dia min. 29 mm, contact material phospher bronze for led, pcb contacts shall be of brass ( tin plated ) , impulse dielectric tested for 2.5 kv, rated insulation resistance shall be 100 m ohm at 500vdc including connection etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . red / yellow / green colour , blue / white colour , providing & fixing of electrical insulating rubber matts as per pwd specification for electrical works, isi marked confirming to is: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 3.3 kv, class a 2 mm thick with proof voltage 10 kv ac ( rms ) and break down voltage 30 kv ac ( rms ) , sitc of ip 40 4 pole current limiting moulded case circuit breaker ( mccb ) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440 / 415 v, 50 hz; o / l & s / c and inst. protection setting , true rms sensing. as per pwd specification for electrical works, conforming to is / iec 60947 p 2 :2003 with front face and centralised adjustable, common fault led indication, thermal memory, release trip shall confirm to emc / emi compatability, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push ( test ) to trip, trip time less then 10 ms under s / c condition, breaking capacity ics = 100% icu. u imp =8 kv, rated insulation voltage 800 v, provision for uvr , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders, etc. as required. oem shall have submit nabl / cpri / erda accrediated lab type test certificate before execution & all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 4 pole mccb withwith microprocessor based release 400 amp , 50 ka, adjustable o / l & adjustable s / c setting, ics = 100 % icu , providing & fixing of 240 / 415 v isolator isi marked is:13947 iii / conforming to iec 60947 3, suitable for ac22a utilization category, 4kv impulse withstand voltage, true contact indication, red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. ip 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. oem shall have submit nabl / cpri / erda accrediated lab type test reports & all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr four pole isolator 100 a rating , supply & fixing of gi pipes confirming to is : 1239 p 1 ( 2004 ) with flanges duly screwed & welded including rubber washer, nuts & bolts of 8mm dia complete in all respect.all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . b class 50 mm dia , p / laying isi marked p.v.c. insulated submersible cable confirming to is:694 with flexible copper conductor including making connection etc. as required 10.0 sq.mm 3 core flat , providing & fixing of single stage, water cooled, high speed ( 2880 rpm ) , horizontal, centrifugal, openwell submersible pumps set pre filled with coolent water and fitted with mechanical seal t / c vs t / c, thrust bearing shall be of carbon + s.s.the stator body of single phase pump shall be of ss and rest of all shall be of cast iron. all casting parts should be cathod electro deposition ( ced ) coated and other construction material should be confirming to is : 14220: 2018 . the overall performance of pump shall confirm to bee energy efficiency level of 3 star. valid bee certificate from oem must be submitted for the same. motor should be ie2 class as per iec 60034 2 1: 2007, iec 60034 30: 2008, & is12615:2011, including making connection etc as required complete in all respect. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 2.0 hp, 1 ø, ( 12 25 ) mtr, ( 350 115 ) lpm , 5.0 hp, 3 ø, ( 14 28 ) mtr, ( 995 500 ) lpm , supply installation testing & commissioning of iso certified company made dol / star delta starter panel made out from 1.6 mm thick powder coated crca sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, illuminated on / off push buttons, ammeter, voltmeter, indicating lamps etc. suitable for following rating motors complete in all respect. appropriate type test certificate / oem test report shall be submitted. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . for three phase submersible / mono block pump 3.0 hp to 10.0 hp ( star / delta starter ) , providing & fixing in position frame made out of m.s. angle ( riveted or welded ) as per is: 2062 2011 finished with two coats of red oxide and two coats of enamel paint including cutting, welding, holes etc. of following sizes as required. all drawing as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 50mm x 50mm x6mm , providing & fixing of digital time switch having following day / week programme and minimum 100 hours reserve and ac1 rating of 16 20 amperes including making connection, programming conforming to iec 60730 1 and 60730 2 7 etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . one day & week reserve ( mechanical type ) , supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from 99.99% purity copper, class 5 stranding in acc. to iec 60228 for lower watt loss , oxygen free ( <10 ppm ) for less chances of oxidization and higher silver content for gives better conductivity , insulation pvc type a or c , flame retardant as per is 10810 53, better amperage rating as per vde 0298 part 4, , in existing surface or recessed pvc / ms conduit / casing capping including all as per pre approved by engineer in charge, making connections, etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of products / work , refer annexure a attached with this bsr . bsr. 1 x 6.0 sq.mm , providing & fixing of 240 / 415 v isolator as per pwd specification for electrical works with isi marked is:13947 iii / conforming to iec 60947 3, suitable for ac22a utilization catagory, 4kv impulse withstand voltage, true contact indication, red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. , label holding facility , ip 20 contact protection and fitted with existing distribution board / sheet including making connections, testing etc. as required. oem shall have submit nabl / cpri / erda accrediated lab test reports before execution & all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . four pole isolator 63 a rating , providing & fixing of 240 / 415 v ac mcb with positive isolation of breaking capacity not less than 10 ka ( b / c tripping characteristic as per type of load and site requirement ) 4kv impulse withstand voltage, as per pwd specification for electrical works with isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , ip 20 contact protection and fitted with existing distribution board / sheets, min. operation 20, 000 upto 32 a rating and 10, 000 upto 63 a, 5000 for 80 a rating including making connections, testing etc. as required. . oem shall have submit nabl / cpri / erda accrediated lab test reports before execution & all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . single pole mcb 6 a to 32 a rating , providing & laying p.v.c. / xlpe insulated & p.v.c. sheathedarmoured aluminium cable of 1.1 kv grade as per pwd specification for electrical works in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points ( a ) , ( b ) , ( c ) , mentioned below: ( a ) material : h4 grade aluminium conductor of purity >99.6 % & as per is:1554 p i / is :7098 p – i ( b ) conductor shall have electrolytic aluminium confirming to is 8130, is 3975 1999 for armouring of cables in armoured cable items , is 5831 for sheath, is 10810 ( part 0 to 64 ) for testingprocedures. ( c ) oem must have iso 9001 & 14001 certifications for quality assuarance & its own in house nabl lab setup for all testing facilities for cables . appropriate type test certificate / oem test report shall be submitted . all above as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr. armoured cable 300 sqmm 3.5 core , 35 sq. mm 3.5 core , 25 sqmm 4 core , 16 sq.mm 4 core , 10 sq.mm 4 core , 6 sq.mm 4 core , 6 sq mm 2 core , supplying and making one end termination with heavy duty brass compression gland ( as per is 12943 1990 ) sibg type, heavy duty aluminium lugs ( as per is 8309 1993 & is 8337 1976 ) duly crimped with crimping tool, pvc tape as per pwd specification for electrical works etc for following size of armoured pvc insulated & pvc sheathed / xlpe aluminium conductor cable of 1100 volt grade as required of size. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . of size 3.5 x 70 sq. mm , of size 3.5 x 35 sq. mm , of size 4 x 10.0 sq.mm , of size 4 x 6.0 sq.mm , of size 4 x 16 sqmm , supplying and making end termination with heavy aluminium lugs pin / ring type ( as per is 8309 1993 & is 8337 1976 ) duly crimped with crimping tool, pvc tape as per pwd specification for electrical works etc of following size. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . size 16.0 sq mm , size 25.0 sq mm , size 35.0 sq mm , size 70.0 sq mm , size 10.0 sq mm , size 6.0 sq mm , dismantling of existing structures like culverts, bridges, retaining walls, cc road and other structure comprising of masonry, cement concrete, wood work, steel work, including t&p and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 50 metres as directed by engineer. cement concrete grade m 15 and above and pcc blocks , providing and laying of double wall corrugated pipe confirming to is :14930 p 1 & 2 with hdpe coupler at 1 mtr. depth below the ground for laying cable including making the trench and back filling, compaction of earth as required ( excavation of earth to be paid extra as required. ) of following outer dia. / inner dia as per is:4984:1994 all as per pre approved by engineer in charge for additional technical parameters of products / work , refer annexure a attached with this bsr . 55 / 50 mm , 90 / 76 mm , supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from 99.99% purity copper, class 5 stranding in acc. to iec 60228 for lower watt loss , oxygen free ( <10 ppm ) for less chances of oxidization and higher silver content for gives better conductivity , insulation pvc type a or c , flame retardant as per is 10810 53, better amperage rating as per vde 0298 part 4, , in existing surface or recessed pvc / msconduit / casing capping including all as per pre approved by engineer in charge, making connections, etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of products / work , refer annexure a attached with this bsr . 2 x 2.5 sq.mm , 2 x 1.5 sq mm , earth work in excavation for roadway, including trimming bottom and side slopes in accordance with requirement of line, grades and cross sections, including disposal of surplus material with all lift and lead upto 1000 metre as per mort&h specification clause 301. in ordinary rock , earth work in excavation for roadway, including trimming bottom and side slopes in accordance with requirement of line, grades and cross sections, including disposal of surplus material with all lift and lead upto 1000 metre as per mort&h specification clause 301. in hard rocks ( blasting prohibited ) , carriage of materials by mechanical transport including loading, unloading and stacking : 3 km , providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering all work upto plinthlevel 1:4:8 ( 1 cement : 4 fine / coarse sand : 8 graded stone aggregate 40 mm nominal size ) . : , providing and laying cement concrete in retaining walls, return walls, walls ( any thickness ) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. upto two stories, excluding the cost of centring, shuttering and finishing : 1:1½:3 ( 1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size ) . , providing & fixing of 240 / 415 v ac mcb with positive isolation of breaking capacity not less than 10 ka ( b / c tripping characteristic as per type of load and site requirement ) 4kv impulse withstand voltage, as per pwd specification for electrical works with isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , ip 20 contact protection and fitted with existing distribution board / sheets, min. operation 20, 000 upto 32 a rating and 10, 000 upto 63 a, 5000 for 80 a rating including making connections, testing etc. as required. . oem shall have submit nabl / cpri / erda accrediated lab test reports before execution & all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . single pole mcb 0.5 a to 2 a rating , providing & fixing of iso certified company made 240 / 415 v porcelain kitkat fuse ( / hbc type ) as per pwd specification for electrical works conforming to is:2086, 1983 on existing board / sheet including making connections with lugs, testing etc. as required . appropriate type test certificate / oem test report shall be submitted . all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 63 a , 415 v , providing & fixing of ac operated heavy duty 230 / 440 volt power contactor as per pwd specification for electrical works, isi marked is / iec 60947 4 1 : 2000 having provision of mechanical interlocking, auxilary contacts, din rail mounting type including making connections, testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 4 pole power contactors with following ac 3 rating 63 amp , s&f following sizes ( dia. ) of isi marked medium duty pvc conduit along with accessories in surface / recessed using saddles, clamps, fastener as required including cutting the wall and making good the same as required. 25 mm , s&f following sizes ( dia. ) of isi marked medium duty pvc conduit along with accessories in surface / recessed using saddles, clamps, fastener as required including cutting the wall and making good the same as required. 40 mm , sitc of quick make and quick break 4 pole current limiting mccb having following current rating, short circuit breaking capacity at 440 / 415 v, 50 hz; o / l & s / c settings and conforming to is 13947 2 / iec 60947 2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for uvr , shunt trip , earth fault trip, push ( test ) to trip , including making connections with lugs / spreaders etc. as required with thermal magnetic release up to 100 amp , 16 / 25 ka, adjustable o / l & fixed s / c setting , p & f in position frame made out of m.s. angle ( riveted or welded ) finished with two coats of red oxide and enamel paint of following sizes as required. 25mm x 25mm x 5mm , sitc of chemical gel earthing system of dual pipe technology made of with b class g i pipe as per is 1239 ( part 1 ) :2004 of medium duty of following sizes as per points mentioned ( a ) , ( b ) , [ c ) , ( d ) , ( e ) below : ( a ) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, cpri / erda tested with rms capacity of minimum 35 40 ka for withstanding 1 second . ( b ) to ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. the compound shall be tested form nabl acredeated lab for low resistivity ( less than 0.12 ohm meter ) & high conductivity in nature with carbon as a major content as per referance of is 3043 1987, ieee 80 2013 ( clause 14.5d ) , ieee 837 & ier 1956 with latest amendemnts ( c ) heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height 250 to 300 mm. ( d ) testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. ( e ) self certificate for confirming above standards from oem is mandatory. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . with pipe in pipe technology ( outer pipe dia. / inner pipe dia. ) minimum 100 mm dia borewell gi pipe 2000 mm long, 80 / 50 mm, terminal 50mm x 6 mm gi strip , supply & laying following size earth strip in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, jointing shall be done by overlapping and with 2 set of brass ( for cu strip ) / gi ( for gi strip ) nut bolt & spring washer spaced at 50cm making connection etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 25mm x 3mm alum. strip , supply & laying following size earth wire in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection with gi / cu thimble etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 8 swg g.i. ( hot dipped ) wire , providing & fixing of ip54 on front microprocessor based three phase sensing power factor correction relay , iec / en 61000 6 ( 2&4 ) having 3 ct sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c / k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag / lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with rs 485, indication ofswitching on units, auto / manual status, and shall have over load protection, no volt release , having multi parameter like kw, kva, kvar, vthd, ithd, metering facility as required. oem shall have submit nabl / cpri / erda accrediated lab test reports. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr 12 to 14 stage , providing & fixing of self healing ip20 mpp type shunt capacitor ( banks ) as per pwd specification for electrical works, isi marked is:13340 41 / conforming to iec :831 1&2 or iec : 60831 1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( psd ) and shall have dissipation factor less than 0.0025 at 50 hz and total wattage loss less than 0.35 watt per kvar. min over current capacity 1.8 times rated current & peak inrush current min. 250 times of rated current, including making connections, testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr heavy duty three phase 525 v, 50 hz cylindrical capacitor ( bank ) ...

Department Of Local Bodies - Rajasthan

36994828 rate contract for repair and maintenance of electrical accessories and wiring in nagar nigam buildings. 1 wiring of light point / fan point / exhaust fan point / call bell point as per pwd specification for electrical works with isi marked 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade ( is:694 ) and 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) in recessed isi marked mms ( is:9537 p iii ) vergin material pvc conduit & its all accessories ( j.b. , bends etc. ) , round tiles, 18 swg g.i. box with earth terminal, 6 a switch , 3 pin ceiling rose / lamp holder / 3 point connector, 3.0 mm thick isi marked phenolic laminated sheet ( is : 2036 1995 ) , al. alloy / cadmium plated iron screws 20 mm cup washers etc. all as per pre approved by engineer in charge, making connections, testing etc. complete as required. for specification of copper conductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 . for additional technical parameters of products / work , refer annexure a attached with this bsr . short point ( up to 3 mtr. ) 2 medium point ( up to 6 mtr. ) 3 long point ( up to 10 mtr. ) 4 wiring of 3 / 5 pin 6 amp. light plug point as per pwd specification for electrical works with isi marked 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade ( is:694 ) and 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) in recessed isi marked mms ( is:9537 p iii ) vergin material pvc conduit & its all accessories ( j.b. , bends etc. ) , round tiles, 18 swg g.i. box with earth terminal of required size, 6 a switch, 3 / 5 pin 6 a socket, 3.0 mm thick isi marked phenolic laminated sheet ( is : 2036 1995 ) , al. alloy / cadmium plated iron screws 20 mm cup washers etc. all as per pre approved by engineer in charge, making connections, testing etc. complete as required. for specification of copper conductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07. for additional technical parameters of products / work , refer annexure a attached with this bsr . on board 5 short point ( up to 3 mtr. ) 6 medium point ( up to 6 mtr. ) 7 long point ( up to 10 mtr. ) 8 s&f following sizes ( dia. ) of isi marked mms ( is:9537 p iii ) vergin material pvc conduit as per pwd specification for electrical works along with its accessories ( is: 3419 ) as required in recess including cutting the wall, covering conduit and making good the same as required. all relative and latest acceptance tests reports by any nabl accredited lab for the conduit shall be submitted before execution & all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr .mms ( is:9537 p iii ) pvc conduit 25mm 9 mms ( is:9537 p iii ) pvc conduit 32mm 10 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from 99.99% purity copper, class 5 stranding in acc. to iec 60228 for lower watt loss , oxygen free ( <10 ppm ) for less chances of oxidization and higher silver content for gives better conductivity , insulation pvc type a or c , flame retardant as per is 10810 53, better amperage rating as per vde 0298 part 4, , in existing surface or recessed pvc / ms conduit / casing capping including all as per pre approved by engineer in charge, making connections, etc. as required. oem must have its own in house nablab setup for all testing facilities for wires. for additional technical parameters of products / work , refer annexure a attached with this bsr .1 x 1.5 sq.mm 11 2 x 1.5 sq.mm 12 1 x 2.5 sq.mm 13 2 x 2.5 sq.mm 14 2 x 4.0 sq.mm 15 supply & drawing wiring for sub mains as per pwd specification for electrical works with isi marked ( is:694 ) , 1100 volts grade pvc insulated flat twin core sheathed solid aluminium conductor with 10 swg g.i. support wire duly clipped including all as per pre approved by engineer in charge, making connections, as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of products / work , refer annexure a attached with this bsr . 4.0 sq.mm 16 6.0 sq.mm 17 10.0 sq.mm 18 supplying and laying isi marked p.v.c. insulated submersible cable as per pwd specification for electrical works confirming to is:694 and as per is 8130 : 2013 of 1.1 kv grade .wire should be made from 99.99% purity copper, class 5 stranding in acc. to iec 60228 for lower watt loss , oxygen free ( <10 ppm ) for less chances of oxidization and higher silver content for gives better conductivity , insulation pvc type a or c , flame retardant as per is 10810 53, better amperage rating as per vde 0298 part 4 including making connection etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. all as per pre approved by engineer in charge, making connections. for additional technical parameters of products / work , refer annexure a attached with this bsr . 2.5 sq.mm 3 core flat / round. 19 providing & fixing of 240 / 415 v ac mcb with positive isolation of breaking capacity not less than 10 ka ( b / c tripping characteristic as per type of load and site requirement ) 4kv impulse withstand voltage, as per pwd specification for electrical works with isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , ip 20 contact protection and fitted with existing distribution board / sheets, min. operation 20, 000 upto 32 a rating and 10, 000 upto 63 a, 5000 for 80 a rating including making connections, testing etc. as required. . oem shall have submit nabl / cpri / erda accrediated lab test reports before execution & all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . single pole mcb 6 a to 32 a rating 20 double pole mcb6 a to 32 a rating 21 four pole mcb40 a rating 22 four pole mcb50 63 a rating 23 providing & fixing of ik09 recessed / surface mounting heavy duty horizontal type sheet steel not less then 1.2 mm thick distribution board as per pwd specification for electrical works isi marked conforming to is 13032 & is 8623 / conforming to iec 61439 3. phosphatised / powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link , connecting wire of suitable rating and din bar, masking sheet, including making internal db terminations with copper lugs and with detachable gland plate, including making connections, testing etc. as required.oem shall have submit nabl / cpri / erda accrediated lab test reports before execution & all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . ip 43 double door ( single phase ) . 8 way ( 8 o / g +2 i / c ) 24 ip 43 double door ( three phase ) 8 way ( 24 o / g + 8 i / c ) 25 providing & fixing of isi marked ( is :3854 ) 6 amp. flush type non modular switch as per pwd specification for electrical works, made out from industrial grade polycarbonate or fire resistant abs material, minimum width of switch toggle ( push part ) should not less then 16 mm, brass terminal & captive screws including cutting hole in tile and making connection testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 26 providing & fixing of isi marked ( is :3854 ) 16 amp. flush type non modular switch as per pwd specification for electrical works, made out from industrial grade polycarbonate or fire resistant abs material , minimum width of switch toggle ( push part ) should not less then 16 mm, brass terminal & captive screws including cutting hole in tile and making connection testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 27 providing & fixing of of 3 pin 6 amp. flush type non modular socket as per pwd specification for electrical works, made out from industrial grade polycarbonate or fire resistant abs material, brass terminal with porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 28 providing & fixing of 3 / 6 pin 16 amp flush type non modular socket as per pwd specification for electrical works, made out fromindustrial grade polycarbonate or fire resistant abs material, brass terminal with porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 29 providing & fixing of isi marked ( is :3854 ) 6 amp. combined flush type non modular socket and switch set as per pwd specification for electrical works, made out from industrial grade polycarbonate or fire resistant abs material, minimum width of switch toggle ( push part ) should not less then 18 mm, brass terminal with porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 30 providing & fixing of isi marked ( is :3854 ) 16 amp. combined flush type non modular socket and switch set with indicator and fuse set as per pwd specification for electrical works, made out from industrial grade polycarbonate or fire resistant abs material, brass terminal with porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 31 providing and fixing of non modular power plug point accessories as per pwd specification for electrical works with 18 swg g i box of size 175 x 100 x 60 mm with earthing terminal / connector on recessed / surface with suitable size phenolic laminated sheet ( is : 2036 1995 ) cover including cost of 16 amp. switch ( is :3854 ) and 3 / 6 pin 16 amp. socket outlet [ as per detailed in respective item in bsr ] , making connection , testing , etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 32 providing & fixing of isi marked ( is:1293 ) 6 amp unbreakable 3 pin plug top with lamp indicator as per pwd specification for electrical works, made out from industrial grade polycarbonate or fire resistant abs material, brass terminal including making connection testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 33 providing & fixing of isi marked ( is:1293 ) 16 amp unbreakable 3 pin plug top with lamp indicator as per pwd specification for electrical works, made out from industrial grade polycarbonate or fire resistant abs material, brass terminal including making connection testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 34 providing & fixing of non modular socket size flush type 120 watt rotary minimum 5 step fan regulator as per pwd specification for electrical works, isi marked ( is:11037 ) made out from industrial grade polycarbonate or fire resistant abs material including making connection testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 35 providing & fixing of isi marked ( is:2268 1994 ) single / multi tone electronic call bell as per pwd specification for electrical works, including making connection testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 36 supply, fixing and testing of following capacity wall mounted stablisers having output voltage variation from 200v to 250v ( + / 5% ) with input voltage variation from 170v to 260v, time delay facility from 2 to 4 minute and high cutoff at 270v complete in all respect e074601 3 kva 37 providing & fixing of ip51 direct or ct operated, 1x240 / 3x240 volts, 50 hz static watt hour meter ( kwh ) as per pwd specification for electrical works, isi marked ( is :13010 2002 ) having resolution 0.1 / 0.01 kwh , accuracy class 1 as per is:13779, led indicators for tamper operation ( reverse & / or earth connection ) , pulsating led indicator for meterology , lcd display, cover plate for body and terminal sealing , push button for all standard parameters, including making connection , testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 10 a to 60 ampere single phase meter. 38 providing & fixing of iso certified company made tp&n 415 v side handle operated double break fuse switch unit in sheet steel enclosure as per pwd specification for electrical works conforming to is / lec 60947 3 : 1999 ( w / o hbc fuses ) including making connections with suitable lugs, testing etc. as required. appropriate type test certificate / oem test report shall be submitted . all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 100 a rating 39 providing & fixing of iso certified company made 240 / 415 v porcelain kitkat fuse ( / hbc type ) as per pwd specification for electrical works conforming to is:2086, 1983 on existing board / sheet including making connections with lugs, testing etc. as required . appropriate type test certificate / oem test report shall be submitted . all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 63 a , 415 v. 40 100 a , 415 v 41 providing & fixing of iso certified company made bus bar chamber housed in sheet metal box as per pwd specification for electrical works confirming to iec 60439 / is 8623 & iec 60529 / is 2147 made out from 1.6 mm thick powder coated crca sheet, degree of protection ip 31 front openable bus bar made out of aluminium or wrought aluminium alloy suitable for 200 amp. capacity , bus bar fixed on porcelain / dmc insulators at approved spacing including making connections etc. as required. appropriate type test certificate / oem test report shall be submitted . all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 300 mm long , 4 strip. 42 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed unarmoured / armoured aluminium cable of 1.1 kv grade as per pwd specification for electrical works in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points ( a ) , ( b ) , ( c ) , mentioned below: ( a ) material : h4 grade aluminium conductor of purity >99.6 % & as per is:1554 p i / is :7098 p – i ( b ) conductor shall have electrolytic aluminium confirming to is 8130, is 3975 1999 for armouring of cables in armoured cable items , is 5831 for sheath, is 10810 ( part 0 to 64 ) for testing procedures. ( c ) oem must have iso 9001 & 14001 certifications for quality assuarance & its own in house nabl lab setup for all testing facilities for cables . appropriate type testcertificate / oem test report shall be submitted . all above as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr. e110110 un armoured 16.0 sq. mm 4 core. 43 un armoured25.0 sq. mm 4 core 44 providing & laying of double wall corrugated pipe confirming to is : 14930 p 1 & 2 with hdpe coupler at 1 mtr. depth below the ground for laying cable including making the trench and back filling , compaction of earth as required ( excavation of earth to be paid extra as required. ) of following outer dia. / inner dia as per is:4984:1995. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr .55 / 50 mm. 45 sitc of chemical gel earthing system of dual pipe technology made of with b class g i pipe as per is 1239 ( part 1 ) :2004 of medium duty of following sizes as per points mentioned ( a ) , ( b ) , [ c ) , ( d ) , ( e ) below : ( a ) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, cpri / erda tested with rms capacity of minimum 35 40 ka for withstanding 1 second . ( b ) to ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. the compound shall be tested form nabl acredeated lab for low resistivity ( less than 0.12 ohm meter ) & high conductivity in nature with carbon as a major content as per referance of is 3043 1987, ieee 80 2013 ( clause 14.5d ) , ieee 837 & ier 1956 with latest amendemnts ( c ) heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height 250 to 300 mm. ( d ) testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. ( e ) self certificate for confirming above standards from oem is mandatory. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . e140510 with pipe in pipe technology ( outer pipe dia. / inner pipe dia. ) minimum 100 mm dia borewell gi pipe 2000 mm long, 50 / 25mm, terminal 40mm x 6 mm gi strip. 46 supply & laying following size earth strip in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, jointing shall be done by overlapping and with 2 set of brass ( for custrip ) / gi ( for gi strip ) nut bolt & spring washer spaced at 50cm making connection etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 25mm x 3mm g.i. ( hot dipped ) strip 47 supply & laying following size earth wire in horizontal or verticalrun in ground / surface / recess including riveting, soldering, saddles, making connection with gi / cu thimble etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 8 swg copper wire. 48 providing & fixing of iso certified company made bee star rated copper wounded double ball bearing capacitor start, aluminium body & metallic blade ceiling fan as per pwd specification for electrical works, conform to all the performance requirements laid down in is:374 2019 including all amendments, as applicable ; & carry bis licensing ( i.e. isi marking ) or quality certification such as iso 9001 or above. with down rod up to 30 cm with secondary support. 1200 mm sweep bee 2 star rated ( service value >=4.5 to < 5 ) . 49 providing & fixing of of double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor , making connections, testing etc. as required. oem shall be an iso certified company. appropriate oem test certificate shall be submitted by contractor. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 225 mm sweep 50 providing & fixing of heavy duty capacitor start, copper wound double ball bearing 900 / 1400 rpm single phase exhaust fan as per pwd specification for electrical works, conforming to is:2312 isi marked in existing opening including making connections testing etc. as required. oem shall be an iso certified company. appropriate oem test certificate shall be submitted by contractor. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 300 mm sweep ( 900 / 1400 rpm ) . 51 providing & fixing of capacitor start, copper wound, metal body, metal blade three speed wall mounting fan of following sweep with the help of anchor bolts including making connection testing etc. as required. oem shall be an iso certified company. appropriate oem test certificate shall be submitted by contractor. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 400 mm sweep ( oscillating type ) . 52 providing & fixing of fluorscent tube rod in existing fixtures as required complete in all respect. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . flourscent powder coated. 36 / 40 watts. 53 providing & fixing of energy efficient / energy saving ip 20 led direct retrofit bulb in existing holder or fixture as required with system lumen efficacy =100 lm / watt output , pf 0.95 , cri >70, minimum life time of minimum 25000 burning hours with , 70% of intial lumen maintaned till life ends , cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be of bis standard and trade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing on housing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 / lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge . foe additional technical parameters of product / work, refer annexure a attacheded with this bsr. 9 watt 54 15 watt 55 rewinding of ceiling fan motor ( starting and running winding ) including all necessary material. the motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enamelled wire with e class insulation material and making connections etc. as required. replacement of material or components shall be use as per guidelines of oem of original product. all the scrap material should be retained by the contractor. ( new model ceiling fan ) . 900 / 1200 mm sweep ( new model ceiling fan ) 56 labour charges for removing and refixing of ceiling fan / exaust fan from site 57 charges for oiling, overhauling of ceiling fan, table fan, pedestal fan irrespect to the size of fan including removing, refixing of fan from site and testing etc. as required. fans with removing & refixing at suitable location. 58 providing and replacement of ball bearing of ceiling / exhaust fan and refixing the same at suitable location as requiredand as per oem recommendations. replacement of material or components shall be use as per guidelines of oem of original product. all the scrap material should be retained by the contractor. 59 p & replacement of cover / bearing seat of ceiling / exhaust fan. replacement of material or components shall be use as per guidelines of oem of original product. all the scrap material should be retained by the contractor. 60 p & f aluminium blades ( a set of 3 blades ) duly painted and well finished 900 / 1200 mm. the material of the fan blade shall be of designation 31500b with condition hx6 aluminium alloy sheet confirming to is 737 / 2008. 61 servicing and overhauling of 20 sweep desert cooler including oiling, greasing, painting of tank from inside with rubber paint after properly desmantling each assembly and refixing the same as required. 62 painting of desert cooler with two coats of rubber paint inside of water tank and two coat of synthetic enamelled paint on both side of cooler body, fan body, grills etc.after cleaning with sand paper, complete in all respect as required. 63 replacement of cooler pads ( heavy ) set of 3 no. of size 25 x 27 64 p & f aluminiun blade for 20 desert cooler fan as required. 65 p & f of isi marked vertical pump suitable for 20 desert cooler including making connection testing etc. as required. isi marked vertical pump. 66 p & f fan motor suitable for 20 desert cooler including making connection testing etc. as required. with copper winding motor isi marked. 67 rewinding of heavy duty exhaust fan motor including all necessary material, the motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size supernamelled wire with e class insulation material and making connections etc. as required. replacement of material or components shall be use as per guidelines of oem of original product. all the scrap material should be retained by the contractor. 300 / 380 mm sweep. 68 rewinding of motor of desert cooler pump with super enamelled copper wire, e class insulation material including removing, refixing, testing etc. as required. replacement of material or components shall be use as per guidelines of oem of original product. all the scrap material should be retained by the contractor. 69 rewinding of motor of desert cooler fan with super enamelled copper wire, e class insulation material including removing, refixing, testing etc. as required. replacement of material or components shall be use as per guidelines of oem of original product. all the scrap material should be retained by thecontractor. 70 supplying and charging of fresh refrigerant and testing of performance of air conditioner / fridge / water cooler of following capacity including capillary and strainer / filter. 1.5 tr window / split a.c. 71 2.0 tr window / split a.c. 72 25 / 50 / 40 / 80 ltr. water cooler 73 replacement of defective compressor by company repaired compressor as per oem recommendations of following gadgets including testing etc. as required. replacement of material or components shall be use as per guidelines of oem of original product. all the scrap material should be retained by the contractor. 1.5 tr a.c. 74 2.0 tr a.c. 75 25 / 50 / 40 / 80 ltr. water cooler 76 p & replacement of condensing / cooling coil of copper fins for following capacity a.c. / water cooler / fridge as required. replacement of material or components shall be use as per guidelines of oem of original product. all the scrap material should be retained by the contractor. 1.5 tr a.c. 77 2.0 tr a.c. 78 25 / 50 / 40 / 80 ltr. water cooler 79 servicing of 1.0 / 1.5 / 2.0 tr capacity split / window type air conditioner. 80 p & replacement of overload protection of a.c. / water cooler as required. replacement of material or components shall be use as per guidelines of oem of original product. all the scrap material should be retained by the contractor. 81 p & replacement of thermostat of a.c. / water cooler / fridge as required. replacement of material or components shall be use as per guidelines of oem of original product. all the scrap material should be retained by the contractor. 82 p & replacement of selector switch of 1.0 / 1.5 / 2.0 tr a.c fan as required. replacement of material or components shall be use as per guidelines of oem of original product. all the scrap material should be retained by the contractor. 83 p & replacement of starting relay of a.c / water cooler / fridge compressor as required. replacement of material or components shall be use as per guidelines of oem of original product. all the scrap material should be retained by the contractor. 84 s & f of capacitor of 230v / 275v, 50hz rating of plastic casing and terminals lugs or copper wire. starting capacitor.40 60 micro farad. 85 60 80 micro farad. 86 running capacitor 2.5 / 3.15 micro farad. 87 4.0 micro farad 88 6.0 micro farad 89 8.0 micro farad 90 10.0 micro farad 91 providing & fixing of ip20 led surface / recessed / suspended mounting mid power smd type led light fixture made from crca sheet steel housing, high purity / transmisivity uv stabilized non yellowish diffuser for uniform light distribution. high efficiency with 2.5 kv internal / external surge protection bis certified isolated driver having efficiency > 85% , with short & open circuit protection and in compliance to iec standards ( integral with light fixture ) . system lumen efficacy min. 100 lm / watt , thd < 10 % , p.f.=0.95, cri >80 , life time of minimum 50000 burning hours with , 70% of intial lumen maintaned till life ends , cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be of bis standard and trade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing on housing. oem must have its own in house nabl acredeated lab setup for all testing facilities for led fixtures. ( lm79 / lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge . for additional technical parameters of product / work, refer annexure a attacheded with this bsr. recessed mounting 48w led light fixture 2x2 with acrylic / prismatic front cover. 92 gas charging of vrf / vrv system with r410a refrigerant gas. before gas charging system shall be flushed with high purity nitrogen gas to remove carbon content, dirt particles to make sure that there is no chance of mixing any impurity with refrigerant gas. thereafter system shall be tested with nitrogen gas at 1.5 times of working pressure of r410 refrigerant gas to ensure leakproof system. whole system shall be vacuumed up to 500 micron level which ensures the zero moisture content level in piping to ensure better cooling efficiency and long life of the system. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr ....

Ministry Of Railways - Rajasthan

36528422 bids are invited for supply of ohe items rdso copper split pin 4x40 mm , m 16 galvanised steel bolt with nut, lock nut and flat washer , contact wire swivel clip pin , gs bolt with nut and lock nut and flat washer , counter weight guide tube , copper split pin , catenary dropper clip complete assembly with nut bolt and copper split pin , contact wire dropper clip complete assembly with nut bolt and copper split pin , locking wire u pin , contact wire pg clamp large with fasteners , contact wire pg clamp small with gi bolt and nut and spring washer , dropper clip 70 mm complete with fasteners , aluminium lug for bec galvanised steel , tee connector suitable for 20mm dia gs wire to 20 mm dia gs wire , straight connector suitable for 20mm dia gs wire to 20 mm dia gs wire galvanised steel , galvanised steel lock nut 16 ln , spring washer b16 galvanised steel , annealed copper split pin 4 x 32 mm , register arm dropper loop solid hard drawn copper dia 7mm , dropper clip 25mm galvanised steel flat , guide tube bracket , standerd backing angle , jumper 50 sqmm , strain clamp 20 mm for feeder wire , earth wire starin clamp , parallel clamp for aerial earth wire set of 2 nos. , ss u bolt with nuts , suspension clamp lock plate annealed copper , contact wire ending clamp 107 , catenary ending clamp 65 , single clevis 18mm forged , ss rope for 3 pulley atd 8 mtr long , register arm dropper 7mm , 5mm rigid dropper copper , 25mm drop bracket assembly , steady arm hook bfb , steady arm , bfb steady arm swivel , stainless steel rope end fitting , galvanised steel high tension nut dia 42mm , galvanised steel high tension check nut dia 42mm , gs j bolt , guide tube bracket 600 , guide tube bracket 550 total quantity : 18005...

Medical And Health Services - Rajasthan

36505975 tender for supply installation testing commissioning of goods lift in district drug ware house at sawai madhopur providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed arrmouredaluminiumcable confirming to is:1554 p i / is :7098 p i of 1.1 kv withh4 grade electrolyticaluminium conductor confirming to is 8130 of purity >99.6 %, round / flat strip armouring of cables, inner / outer sheath confirming to is:5831in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench / cable tray ( with cable tie ) includingtesting etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810.for additional technical parameters of product / work refer annexure a attached with this bsr 2 25.0 sq. mm3.5 core 3 supplying and making one end termination with nickel plated heavy duty brass single compression gland ( as per is 12943 1990 ) ) sibg type consisting of check nut, gland body, metal washer ( 3 nos. ) , outer seal rubber ring, compression nut, heavy duty aluminium lugs ( as per is 8309 1993 ) duly crimped with crimping tool, pvc tape as peris 8337 1976offollowing size ofpvc insulated & pvc sheathed / xlpe aluminium conductor cable of 1100 volt grade as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 4 3.5 x 25.0 sq.mm 5 wiring of light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked mms ( is:9537 p iii ) virgin material pvc conduit & itsisi marked ( is:3419 1988 ) accessories, round tiles, 1.2 mm thickhot dipped galvanized modular box with earth terminal, 10a modular switch, modular face plate with grid plate, 3 pin ceiling rose / holder / 3 way connector, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 6 short point ( up to 3 mtr. ) 7 medium point ( up to 6 mtr. ) 8 wiring of 3 / 5 pin 6 amp. light plug point with 1.5 sq. mm nominal sizefr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked mms ( is:9537 p iii ) pvc conduit & its isi marked ( is:3419 1988 ) accessories, hot dipped galvanizedmodular box of 1.2 mm thick with earth terminal, 10 a modularswitch, 3 / 5 pin 6 a modular socket, modular face plate with grid plate, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 9 on board 10 providing & fixing of 240 / 415 v ac mcb with positive isolation of 10 ka breaking capacity ( b / c / d tripping characteristic as per type of load andsite requirement ) 4 kv impulse withstand voltage, isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted inexisting distribution board / sheets, minimum electrical operation 20, 000 upto 20 a rating and 10, 000 upto 63 a, 5000 for 80 a & above ratingincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 11 single pole mcb ( with b / c curve tripping characteristics ) 6 a to 32 a rating 12 four pole mcb ( with b / c curve tripping characteristics ) 50 / 63 a rating 13 providing & fixing of 240 / 415 v factory fitted rcbo with overload, short circuit and earth leakage protectionwith isi marked ( is12640 2 ) / conforming to iec 61009 1, breaking capacity 10 ka, provision for pad lock, min. electrical operation 10, 000 upto 63 a rating , minimum phase termination capacity of 35sq.mm. , ip 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 14 four pole 100 / 300 ma sensitivity63 a rating 15 providing & fixing of recessed / surface mounting heavy duty horizontal type double door ( metal / glazed ) distribution board with metal end box made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3, powder painted complete with reversible door ( for double door db only ) 100 amp. insulated copper bus bar / shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar, masking sheet, making internal db terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 16 metal door ( single phase ) ik 09 and ip 43 with metal end box12 way ( 12+2 ) 17 supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % copperthickness ( 250 microns ) andconfirming toul 467, is / iec 62561 2of following size and length and as per point mentioned ( a ) , ( b ) , [ c ) , ( d ) , ( e ) below : 18 ( a ) bore a hole of dia. 100 mm of required length, place the rod in the centre of hole 19 ( b ) filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, cpri / erdatested with rms capacity of minimum 30 ka for withstanding 1 second .to ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. the compound shall be tested form nabl acredeated labfor lowresistivity ( less than 0.12 ohm meter ) & high conductivity in nature with carbon as a major contentas per referance of is 3043 1987, ieee 80 2013 ( clause 14.5d ) , ieee 837 & ier 1956 with latest amendemnts 20 © connect the rod with copper strip / conductor / wire with suitable clamp made from tinned copper and ss 304 bolt 21 ( d ) place heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height250 to 300 mm. 22 ( d ) testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 23 ( e ) test certificatesfor confirming above standards from oem is mandatory. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 24 17.2 mm thick and 3 mtr. long 25 supply & laying following size earth wire in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection with gi / cu purity purity >95%thimble etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 26 8 swg copper wire 27 25mm x 3mm g.i. ( hot dipped ) strip 28 providing & fixing of energy efficient / energy saving ip 20 led direct retrofit bulbin existing holder or fixture as required with system lumen efficacy =100 lm / watt output , pf 0.95 , cri >70, minimum life time of minimum25000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 / lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge . for additional technical parameters of product / work, refer annexure a attacheded with this bsr. 29 9 watt 30 providing & fixing of ip65 ik08 rated integrated smd mid power led bulk head type light fixture made from pressure die cast al housing suitable with integral driver, system lumen efficacy =100 lm / watt output , thd < 10% , p.f.=0.95, cri >80 , life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. surge protection 4 kv. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 31 minimum lumen output 1000 lm 32 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from99.90 % purity copper, class 5 stranding in acc. to is:8130 / iec 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation pvc type a / c / d , flame retardant as per is 10810 53, better amperage rating as per is:3961 part 5, in existingsurface or recessed pvc / ms conduit / casing capping making connections with copper lugs of suitable size, ferrules, testing etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of product / work refer annexure a attached with this bsr 33 2 x 2.5 sq. mm. + 1x1.5sqmm 34 s&f following sizes ( dia. ) of isi marked virgin material mms ( is:9537 p iii ) pvc conduit along withisi marked ( is:3419 1988 ) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. for additional technical parameters of product / work refer annexure a attached with this bsr 35 25 mm...

Medical And Health Services - Rajasthan

36505951 tender for supply installation testing commissioning of goods lift in district drug ware house at bundi providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed arrmouredaluminiumcable confirming to is:1554 p i / is :7098 p i of 1.1 kv withh4 grade electrolyticaluminium conductor confirming to is 8130 of purity >99.6 %, round / flat strip armouring of cables, inner / outer sheath confirming to is:5831in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench / cable tray ( with cable tie ) includingtesting etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810.for additional technical parameters of product / work refer annexure a attached with this bsr 2 25.0 sq. mm3.5 core 3 supplying and making one end termination with nickel plated heavy duty brass single compression gland ( as per is 12943 1990 ) ) sibg type consisting of check nut, gland body, metal washer ( 3 nos. ) , outer seal rubber ring, compression nut, heavy duty aluminium lugs ( as per is 8309 1993 ) duly crimped with crimping tool, pvc tape as peris 8337 1976offollowing size ofpvc insulated & pvc sheathed / xlpe aluminium conductor cable of 1100 volt grade as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 4 3.5 x 25.0 sq.mm 5 wiring of light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked mms ( is:9537 p iii ) virgin material pvc conduit & itsisi marked ( is:3419 1988 ) accessories, round tiles, 1.2 mm thickhot dipped galvanized modular box with earth terminal, 10a modular switch, modular face plate with grid plate, 3 pin ceiling rose / holder / 3 way connector, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 6 short point ( up to 3 mtr. ) 7 medium point ( up to 6 mtr. ) 8 wiring of 3 / 5 pin 6 amp. light plug point with 1.5 sq. mm nominal sizefr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked mms ( is:9537 p iii ) pvc conduit & its isi marked ( is:3419 1988 ) accessories, hot dipped galvanizedmodular box of 1.2 mm thick with earth terminal, 10 a modularswitch, 3 / 5 pin 6 a modular socket, modular face plate with grid plate, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 9 on board 10 providing & fixing of 240 / 415 v ac mcb with positive isolation of 10 ka breaking capacity ( b / c / d tripping characteristic as per type of load andsite requirement ) 4 kv impulse withstand voltage, isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted inexisting distribution board / sheets, minimum electrical operation 20, 000 upto 20 a rating and 10, 000 upto 63 a, 5000 for 80 a & above ratingincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 11 single pole mcb ( with b / c curve tripping characteristics ) 6 a to 32 a rating 12 four pole mcb ( with b / c curve tripping characteristics ) 50 / 63 a rating 13 providing & fixing of 240 / 415 v factory fitted rcbo with overload, short circuit and earth leakage protectionwith isi marked ( is12640 2 ) / conforming to iec 61009 1, breaking capacity 10 ka, provision for pad lock, min. electrical operation 10, 000 upto 63 a rating , minimum phase termination capacity of 35sq.mm. , ip 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 14 four pole 100 / 300 ma sensitivity63 a rating 15 providing & fixing of recessed / surface mounting heavy duty horizontal type double door ( metal / glazed ) distribution board with metal end box made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3, powder painted complete with reversible door ( for double door db only ) 100 amp. insulated copper bus bar / shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar, masking sheet, making internal db terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 16 metal door ( single phase ) ik 09 and ip 43 with metal end box12 way ( 12+2 ) 17 supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % copperthickness ( 250 microns ) andconfirming toul 467, is / iec 62561 2of following size and length and as per point mentioned ( a ) , ( b ) , [ c ) , ( d ) , ( e ) below : 18 ( a ) bore a hole of dia. 100 mm of required length, place the rod in the centre of hole 19 ( b ) filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, cpri / erdatested with rms capacity of minimum 30 ka for withstanding 1 second .to ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. the compound shall be tested form nabl acredeated labfor lowresistivity ( less than 0.12 ohm meter ) & high conductivity in nature with carbon as a major contentas per referance of is 3043 1987, ieee 80 2013 ( clause 14.5d ) , ieee 837 & ier 1956 with latest amendemnts 20 © connect the rod with copper strip / conductor / wire with suitable clamp made from tinned copper and ss 304 bolt 21 ( d ) place heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height250 to 300 mm. 22 ( d ) testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 23 ( e ) test certificatesfor confirming above standards from oem is mandatory. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 24 17.2 mm thick and 3 mtr. long 25 supply & laying following size earth wire in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection with gi / cu purity purity >95%thimble etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 26 8 swg copper wire 27 25mm x 3mm g.i. ( hot dipped ) strip 28 providing & fixing of energy efficient / energy saving ip 20 led direct retrofit bulbin existing holder or fixture as required with system lumen efficacy =100 lm / watt output , pf 0.95 , cri >70, minimum life time of minimum25000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 / lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge . for additional technical parameters of product / work, refer annexure a attacheded with this bsr. 29 9 watt 30 providing & fixing of ip65 ik08 rated integrated smd mid power led bulk head type light fixture made from pressure die cast al housing suitable with integral driver, system lumen efficacy =100 lm / watt output , thd < 10% , p.f.=0.95, cri >80 , life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. surge protection 4 kv. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 31 minimum lumen output 1000 lm 32 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from99.90 % purity copper, class 5 stranding in acc. to is:8130 / iec 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation pvc type a / c / d , flame retardant as per is 10810 53, better amperage rating as per is:3961 part 5, in existingsurface or recessed pvc / ms conduit / casing capping making connections with copper lugs of suitable size, ferrules, testing etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of product / work refer annexure a attached with this bsr 33 2 x 2.5 sq. mm. + 1x1.5sqmm 34 s&f following sizes ( dia. ) of isi marked virgin material mms ( is:9537 p iii ) pvc conduit along withisi marked ( is:3419 1988 ) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. for additional technical parameters of product / work refer annexure a attached with this bsr 35 25 mm...

Medical Health And Family Welfare - Rajasthan

36433514 electrical work in the construction of phc building at badka ( laxmangarh ) distt. alwar wiring of light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked mms ( is:9537 p iii ) virgin material pvc conduit & itsisi marked ( is:3419 1988 ) accessories, round tiles, 1.2 mm thickhot dipped galvanized modular box with earth terminal, 10a modular switch, modular face plate with grid plate, 3 pin ceiling rose / holder / 3 way connector, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 3 short point ( up to 3 mtr. ) 4 medium point ( up to 6 mtr. ) 5 long point ( up to 10 mtr. ) 6 wiring of twin control light point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) in recessed isi markedmms ( is:9537 p iii ) pvc conduit & its isi marked ( is:3419 1988 ) accessories, round tiles, 2 nos hot dipped galvanized m.s modularbox of 1.2 mm thickwith earth terminal, 2 nos10 a two way modular switch, 3 pin ceiling rose / holder / 3 way connector , modular face plate with grid plate, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 7 medium point ( up to 6 mtr. ) 8 long point ( up to 10 mtr. ) 9 wiring of 3 / 5 pin 6 amp. light plug point with 1.5 sq. mm nominal sizefr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked mms ( is:9537 p iii ) pvc conduit & its isi marked ( is:3419 1988 ) accessories, hot dipped galvanizedmodular box of 1.2 mm thick with earth terminal, 10 a modularswitch, 3 / 5 pin 6 a modular socket, modular face plate with grid plate, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 10 on board 11 s&f following sizes ( dia. ) of isi marked virgin material mms ( is:9537 p iii ) pvc conduit along withisi marked ( is:3419 1988 ) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. for additional technical parameters of product / work refer annexure a attached with this bsr 12 20 mm 13 25 mm 14 32 mm 15 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from99.90 % purity copper, class 5 stranding in acc. to is:8130 / iec 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation pvc type a / c / d , flame retardant as per is 10810 53, better amperage rating as per is:3961 part 5, in existingsurface or recessed pvc / ms conduit / casing capping making connections with copper lugs of suitable size, ferrules, testing etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of product / work refer annexure a attached with this bsr 16 1 x 1.5 sq.mm 17 3x 1.5 sq.mm 18 2 x 2.5 sq. mm. + 1x1.5sqmm 19 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 20 4 x 10.0 sq.mm 21 4 x 6.0 sq.mm 22 1 x 4.0 sq.mm 23 1 x 2.5 sq.mm 24 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. 25 supplying and drawing pe insulated & pvc sheathed unarmoured telephone cable with 0.5 mm dia. solid annealed electrolytic grade bare copper conductor as per is: 8130 / 84 &confirming to tec specification gr / wir / 06 03 march 2002in existingsurface or recessed conduit / casing capping. including ferruling on each pair for identification etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 26 2 pair 27 p & f in position frame made out of m.s. angle ( riveted or welded ) finished with two coats of red oxide and two coats enamel paint including cutting, welding, holes etc.of following sizes as required.for additional technical parameters of product / work refer annexure a attached with this bsr 28 40mm x 40mm x 5mm 29 p & f paper phenolic resin bondedlaminates confirming to is : 2036 1995 for boxes / frames including making holes for switches etc, with brass screws, washers / zinc platednut and bolts as required. for additional technical parameters of product / work refer annexure a attached with this bsr 30 6.4 mm thick 31 p & f phenolic laminated sheet 2.0 mm thick of following size . including screws, cup washer as required.for additional technical parameters of product / work refer annexure a attached with this bsr 32 75 mm dia 33 providing & fixing of 240 / 415 v ac mcb with positive isolation of 10 ka breaking capacity ( b / c / d tripping characteristic as per type of load andsite requirement ) 4 kv impulse withstand voltage, isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted inexisting distribution board / sheets, minimum electrical operation 20, 000 upto 20 a rating and 10, 000 upto 63 a, 5000 for 80 a & above ratingincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 34 single pole mcb ( with b / c curve tripping characteristics ) 35 6 a to 32 a rating 36 double pole mcb ( with b / c curve tripping characteristics ) 37 6 a to 32 a rating 38 four pole mcb ( with b / c curve tripping characteristics ) 39 6 a to 32 a rating 40 50 / 63 a rating 41 providing & fixing of recessed / surface mounting heavy duty horizontal type double door ( metal / glazed ) distribution board with metal end box made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3, powder painted complete with reversible door ( for double door db only ) 100 amp. insulated copper bus bar / shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar, masking sheet, making internal db terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 42 metal door ( single phase ) ik 09 and ip 43 with metal end box 43 16 way ( 16+2 ) 44 metal door ( three phase ) ik 09 and ip 43with metal end box 45 6 way 46 p&f metal clad / plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain / bakelite base in recessed / surface mounting heavy duty enclosure made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3. powder painted ( without mcb ) including making connections, testing etc.as required.for additional technical parameters of product / work refer annexure a attached with this bsr 47 20 amp, 3 pin + scrapping earth, 4 module 48 p & f of industrial plug and socket conforming to iec 60309 1 / 2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. for additional technical parameters of product / work refer annexure a attached with this bsr 49 ip 67 panel mounted socket 50 32 a 3 pin ( 2p+e ) 51 providing & fixing of flush typenon modular single line telephone jackmade out fromindustrial grade polycarbonate or fire resistant abs material, including making connection testing etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 52 providing & fixing of ding dong / musical chime bell as per pwd specification for electrical works, including making connection testing etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 53 providing & fixing of modular type 120 w step fan regulator duly isi marked ( is 11037:1984 ) with cm / l no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , includingall as per pre approved by engineer in charge, making connections, testing etc. as required.for additional technical parameters of product / work refer annexure a attached with this bsr 54 5 step fan regulator 2 module 360 dgree rotating 55 supplying and fixing of power plug point with modular accessories as per pwd specification for electrical works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal / connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofisi marked modular 16 amp. switch ( is :3854 ) and 6 / 16 amp. socket outlet ( is:1293 ) making connection , testing , etc. as required. for specification ofwiring accessories refer chaptere 07related item & for additional technical parameters of product / work refer annexure a attached with this bsr 56 p & f krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted, including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 57 10 pairs 58 sitc of ip 42 and general construction confirming to is:8623 : 1993, wall / free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andother parameters requiredas per point ( a ) , ( b ) , ( c ) , ( d ) , ( e ) , ( f ) , ( g ) , ( h ) as below: 59 ( a ) thickness of crca sheet shallbe 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 60 ( b ) complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel.the panel having pe foam / neoprene rubber gasket of not less than 3mm thickness , required hardware , concealed hinged door with key type locking arrangement for equipment / switchgear earthed with 2.5 sq.mm braided copper wire. 61 [ c ) interconnection between bus bar and switchgears / cable shall be rigidly supported and made out by flexible copper wires ( up to 63 amp ) and by solid bus bar ( >63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only.all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgearis to be paid extra ) 62 ( d ) wiring between components within switchgear and incoming / outgoing cableshall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 63 ( e ) all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be ‘point to point’ ( no wire splitting or tee connections ) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 64 ( f ) floor mounted panel shall be mounted on base frame of ismcchannel size 100 x 50 x 5 mm ( to be paid extra ) 65 ( g ) tests: the insulation resistance ( with 1000 v megger ) and high voltage power frequency test ( by applying a voltage of 2.5kv for one minute ) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. the insulation resistance shall not be less than three megaohm. ct secondary current injection test shall also be carried out. 66 ( h ) only outer surface area on all sides shall be measured & panel to be fabricated only from cpri approved fabricator only ( cpri test certificates to be submitted ) all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 67 supplying and fixing of aluminium ( iec 60105 iso 209 1, 2 ) / copper ( iec 60028 ) bus bar by means of smc / dmc type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 68 electrolytic grade aluminium bus bar 6010 grade 69 providing & fixing of bis approvedcurrent transformeras per pwd specification for electrical works , isi marked as peris 2705 1992 / conforming to iec 60044 1, with secondary terminalof ct shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredcurrent transformer ring type tape wound / resin cast wound as per is 16227 with, accuracy cl, ct ratio and burden as specified. isf<=5, cu cross section of secondary wire 1.5sqmm ( minimum ) , including all necessary support in existing panel including connection etc. as required . all as per pre approved by engineer in charge.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 70 ring type tape wound ct 71 c t class 1, ratio 200 / 5 to 300 / 5, burden 10 va 72 providing & fixing of110 / 220 v, unibody led indicatinglamp iec 60947with integral circuit, ip 65 above panel &ip 20 terminal block, approx. body dia for panel not less then 20 mm, length min. 50mm, front led cover dia min.29 mm, contact material phospher bronze for led, pcb contacts shall be ofbrass ( tin plated ) , impulsedielectric tested for 2.5 kv, rated insulation resistance shall be 100 m ohm at 500vdcincluding connection etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 73 red / yellow / green colour 74 providing & fixing of electricalinsulating rubber matts as per pwd specification for electrical works, isi marked confirming to is: 15652 / 2006with one sideanti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 75 3.3 kv, class a 2 mm thick with proof voltage 10 kv ac ( rms ) and break down voltage 30 kv ac ( rms ) 76 sitc of3 / 4pole current limiting moulded case circuit breaker ( mccb ) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440 / 415 v, 50 hz; o / l & s / c settings , conforming to is / iec 60947 p 2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push ( test ) to trip, trip time less then 10 ms under s / c condition, breaking capacity ics = 100% icu. u imp =8 kv, rated insulation voltage690 v.provision for uvr , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.oem shall have submitnabl / cpri / erda accrediated lab type test certificate before execution all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 77 4 pole mccb with thermal magnetic release 78 125 amp , 25 ka, adjustable o / l & adjustable s / c setting, 79 up to 100 amp , 25 ka, adjustable o / l & adjustable s / c setting, 80 providing & fixing of iso certified company made on load change over switch, front handle operated, four pole 415 v as per pwd specificationfor electrical works conforming to is / lec 60947 3 : 1999 including connections , testing etc. as required .in the following rating.appropriate type test certificate / oem test report shall be submitted .all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 81 open execution type 82 160 a 83 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed arrmouredaluminiumcable confirming to is:1554 p i / is :7098 p i of 1.1 kv withh4 grade electrolyticaluminium conductor confirming to is 8130 of purity >99.6 %, round / flat strip armouring of cables, inner / outer sheath confirming to is:5831in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench / cable tray ( with cable tie ) includingtesting etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810.for additional technical parameters of product / work refer annexure a attached with this bsr 84 10.0 sq. mm 85 2 core 86 35.0 sq. mm 87 3.5 core 88 supplying and making one end termination with nickel plated heavy duty brass single compression gland ( as per is 12943 1990 ) ) sibg type consisting of check nut, gland body, metal washer ( 3 nos. ) , outer seal rubber ring, compression nut, heavy duty aluminium lugs ( as per is 8309 1993 ) duly crimped with crimping tool, pvc tape as peris 8337 1976offollowing size ofpvc insulated & pvc sheathed / xlpe aluminium conductor cable of 1100 volt grade as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 89 3.5 x 35.0 sq.mm 90 supplying and makingend termination with heavy aluminiumlugs ( pin / ring type ) confirming to is 8309 1993 & is 8337 1976 duly crimped with crimping tool, pvc tape etc of following size.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 91 35.0 sq.mm 92 supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % copperthickness ( 250 microns ) andconfirming toul 467, is / iec 62561 2of following size and length and as per point mentioned ( a ) , ( b ) , [ c ) , ( d ) , ( e ) below : 93 ( a ) bore a hole of dia. 100 mm of required length, place the rod in the centre of hole 94 ( b ) filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, cpri / erdatested with rms capacity of minimum 30 ka for withstanding 1 second .to ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. the compound shall be tested form nabl acredeated labfor lowresistivity ( less than 0.12 ohm meter ) & high conductivity in nature with carbon as a major contentas per referance of is 3043 1987, ieee 80 2013 ( clause 14.5d ) , ieee 837 & ier 1956 with latest amendemnts 95 © connect the rod with copper strip / conductor / wire with suitable clamp made from tinned copper and ss 304 bolt 96 ( d ) place heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height250 to 300 mm. 97 ( d ) testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 98 ( e ) test certificatesfor confirming above standards from oem is mandatory. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 99 17.2 mm thick and 3 mtr. long 100 supply & laying following size earth wire in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection with gi / cu purity purity >95%thimble etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 101 8 swg copper wire 102 8 swg g.i. ( hot dipped ) wire 103 making of hole in wall ( brick / stone ) of required and placing np 2 rcc pipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 104 up to 457 mm size 105 providing & fixing ofbeestar rated copper wounded double ball bearing capacitor start, aluminium body & metallicblade ceilingfanconforming to all the performance requirements laid down in is 374:2019 including all amendments, as applicable ; & carry bis licensing ( i.e. isi marking ) with down rod up to 80 cm with secondary support safety cable ( steel rope ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 106 1200 mm sweep bee 2 star rated ( service value >=4.5 to < 5 ) 107 1200 mm sweep bee 3 star rated ( service value >=5.0 to< 5.5 ) 108 p & f 1.2mm thickm.s. recessed fan box, hexagonal / round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mmlength extended on each side . all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr 109 p & f 1.2mm thickm.s. recessed fan box, hexagonal / round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mmlength extended on each side . all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr 110 providing & fixing ofof double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor , making connections, testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 111 225 mm sweep 112 providing & fixing of heavy duty capacitor start, copper wounddouble ball bearing900 / 1400 rpm single phaseexhaustfan conforming to is:2312 isi marked in existing opening including making connections testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 113 300 mm sweep ( 900 / 1400 rpm ) 114 providing & fixing of wall mounting / pedestal type heavy duty air circulator , double ball bearing and with metal sturdy mesh guard; aluminium alloy one piece blade and conforming to is:2997, including fixing with anchor bolts, making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 115 450 mm sweep wall mounting and three speed regulator with minimum air delivery 150 cum. / minute 116 p & f of gravity louver shutter of superior quality made out of frame of18 swg m.s. sheet & louvers made from 24 swg ms sheetwith enamel paint including cost of nuts, bolts, etc as reqd.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 117 up to 380 mm size 118 providing & fixing of vertical ( bee 5 star rated ) / horizontal ( bee 3 star rated ) storage water heater with outer casing made of engineering plastic sheet ( upto 25 ltr ) / metal rust proof body ( 35 & 50 ltr ) , glass line / titanium enamel coated pressure pump compatible 8 bar pressure inner tank, glass line coated , mineral filled heating element, stem type, snap actionadjustable thermostat , dual indicating lampsinjected puf insulation, multi function valve etc. as required held in position with 2 / 4 no. 10 / 12 mm anchor fastener, duly wired with 3 core 2.5 / 4.0 sqmm pvc insulated & sheathed copper conductor and 16 a / 25a three pin plug top with portable residual current device ( prcd ) , including making inlet, outlet flexible alloyconnection, testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 119 15 ltr. 120 sitc ofmnre approved & confirming to is:12933 p 1, 2, 3 & 5 flat plate collector type solar hot water system havingcollector withzincalum sheet outer body , glass line / titanium enamel coated inner tank with metal rust proof puf insulated body includingelectrical back up, thermostat, powder coated / hot dipped galvanized ms standfor collector & tank etc. as required. of following capacity complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 121 200 litre / day 122 providing & fixing of energy efficient direct fit ( retrofit ) polycarbonate / glasshousingsmd mid power led tube rod ( with integral driver & alumn. heat sink ) , on existing fixture.system lumen efficacy = 100 lm / watt output, internal surge protection of 2.5 kv , thd < 20% , p.f.=0.95, cri >80 , life time of minimum35000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 123 1200mm , min. lumens output 2000 lmled tube rod with polycarbonate housing 124 providing & fixing of ip 20 led recessed / surface mounted, round / sqauresmd mid power led downlight with power coated die cast aluminum housingwith uv stabilized non yellowish diffuser withbis complience 2.5 kv surge protected isolated driver, with short & open circuit protection, having efficiency > 85% . system lumen efficacy of = 110 lm / watt, thd < 10 % , pf.=0.95, cri >80, life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. 125 oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 126 surface mounting ( with extruded alumn. housing ) 127 minimum lumen output 1950 lm 128 providing & fixing of ip20, 2x2 led surface / recessedmounting mid power smd type led light fixture not less than 50mm housing depth made from crca sheet steel housing, high purity / transmisivity uv stabilized non yellowish diffuser for uniform light distribution. high efficiency with 4 kv internal / external surge protection bis certified isolated driver having efficiency > 85% , with short & open circuit protection ( integral with light fixture ) . system lumen efficacy of = 120 lm / watt , thd < 10 % , p.f.=0.95, cri >80 , life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. 129 oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 130 recessed mounting 131 minimum lumen output 4200 lm 132 providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket / pole. fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with uv stabilized pc ( uv stablization report submitted for uv cover ) / toughened glass coverand secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm / wt and potted driver& has a unique bis r number withinput voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driverefficiency >85%, thd ( i ) <10%humidity 10% to 90% rh working temp 5c to 45c .driver current <750ma. the luminaireshall be bis certified and trade mark certified. life expectancyequal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min = 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs.manufactures word mark / name engraved / embossing on die cast housing to allow traceability / authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities forled fixtures. ( lm79 / lm80 ) certificate / report with liable warranty of product / accessories from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 133 led street light fixture with minimum lumen output 2450 lm 134 providing & fixing of street light bracket made out from following size of b class , medium class g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with heavy duty pole clamp, saddles suitable fastners etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 135 25 mm dia. 136 supply, drawing and testing of 4 pair, 23 awg solid bare copper wire insulated with pvc, utp ( unshielded twisted pair ) , category 6, class e, 100 ohm impedance, indoor cable as per latest ammendments of ansi / tia / eia 568 , the copper conductors should be balanced twisted in pairs, seperated by a cross member fluted pair divider & protected bypvc jacket. certified performance in a 4 connector configuration upto 100 mtrs channel requirements & transmission frequencies up to 250 mhz. in existing ms / pvc conduits / casing capping including making connections to information outlets and patch panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 137 supply and installation of unsheilded / 360 degree sheilded information outlets made of high impact plastic body with abs, fr grade halogen free material with provision for protection against dust in jack, suitable for cat 6 / 6a application complying to latest ammendments, according. to cat. 6 / 6a channel, it should support channel as well as components requirements of cat.6 / 6a standards at frequencies of up to 250 to 500 mhz. cat 6 / 6a unshielded / shielded jack should be suitable to terminate 4 pair, 23 / 24 awg solid / stranded wire diameters, using 100 ohm unshielded / shielded balance twisted pair cable, the jack should have tooless / impact termination on reliable copper tin plated insulation displacement contact, with easy lock mechanism, it supports iec 60603 7 4 and complied with ansi / tia / eia 568 c.2 standard. jack should be rj11, rj12 & rj45 compatible. should support ethernet 1.2 gb / s atm, digital video and broadband / baseband analog video, voice over internet protocal ( voip ) specifications in existing modular / ms boxes along with necessory connections as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 138 cat 6, un sheilded information outlet 139 supply & fixing of square faceplate for flush / surface mount information outlets single / dual or quad aperture , material should bepc+abs body, suitable for rj45 unshielded / shielded connection modules. should match with i. o. oem. dimensions should be 86mm x 86mm as required complete in all respect.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 140 single aperture 141 supply , installation and testing of 4 pair, 100 ohm impedance, cat 6 / 6a / class e / ea patch cords should be constructed of minimum 23 / 24 awg, stranded bare copper cable with frpvc / lszh jacket, with an enhanced performance by factory moulded rj45 connectors with strain relief boots as per ansi / tia / eia 568 c.2 suitable for cat 6 / 6a application complying to latest ammendments category 6 / 6a standards, according. to tia568c.2, iso / iec 11801, en 50173, iec 60603 7 51, en 60603 7, ieee 802.3an minimum requirement for 1g base t to 10g base t performance. patch cords shall be straight thru cable compatible with both t568 a and t568 b wiring schemes, should support ieee 802.3af / ieee 802.3at for poe applications, minimum 750 to 1000 mating cycles in plug contacts for long durability, should support ethernet 10gbase t, 1.2 gb / s atm, token ring 4 / 16, digital video and broadband / baseband analog video, voice over internet protocal ( voip ) .all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 142 cat 6, u / utp ( unscreened / un sheilded twisted pair ) patch cord 143 1 mtr 144 supply, installation, & testing of 19 1u rack mounted / surface mounted aluminum / crca 1.2mm powder coated, multimode glass fiber optic cable patch panel / liu loaded with flangless / screwable adapters for st / e 2000 / sc / lc / mt rj / pc type, it should have easy removable top plate with push buttons, there should be a splice tray installed in the patch panel / liu which can handle the fiber cores, splice tray should be pc+abs material, it should include accessories like mounting hardware, gormetts, heat shrink tubes / sleevs, screws, nuts to install the panel for rack / wallmount applications as per requirement complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 145 multi mode liu 12 ports 146 supply & installation of ip 20 & ik 08 , ul listedwall mounted double section communication enclosure ( rack ) made from powder coated ( 60 to 80 micron ) crca sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door, vertical mounting rail 1.6 mm with umarking , with all round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. accessories like: 1 no of 19 1u horizontal cable manager, 1 no of 90 cfm 230v ac fan with 1 mts long cable, mounting hardware , 1 no of 19 1u, mountable socket strips with 5 nos of 5a universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with suitable anchor fastneretc as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 147 6 u rack with width 600 mm &depth 400 mm + 100 mm 148 supply , installation, testing and comissioning ofmanaged layer 2 intelligent 10 / 100 ethernet switch providing 24 x 10 / 100 / 1000 mbps giga ethernet ports / with min 2 sfp giga ports ( provision for fiber giga connectivity ) with related lan base software including making connections etc as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 149 sitc of single stage, water cooled, high speed ( 2880 rpm ) , horizontal, centrifugal, openwell submersible pumps set pre filled with coolent water and fitted with mechanical seal t / c vs t / c, thrust bearing shall be ofcarbon + s.s.the stator body of single phase pumpshall be of ss and rest of all shall be of cast iron. all casting parts should be cathod electro deposition ( ced ) coated and other construction material should be confirming to is : 14220: 2018 . the overall performance of pump shall confirm to bee energy efficiency level of 3 star. valid bee certificate from oem must be submitted for the same. motor should be ie2 class as per iec 60034 2 1: 2007, iec 60034 30: 2008, & is12615:2011, including making connection etc as required complete in all respect. oem shall have submitnabl / cpri / erda accrediatedlab type test certificate before execution. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 150 1.0 hp, 1 ø, ( 7 12 ) mtr, ( 405 240 ) lpm 151 sitc of monoblock motor pump set isi marked ( is:9079 2002 ) with tefc motor, motor should be ie2 class as per iec 60034 2 1: 2007, iec 60034 30: 2008, & is12615:2011. with stainless steel impellor, stainless steel shaft, mechanical seal, single / three phase ( 240 440 v ) permanent split capacitor type ( psc ) , fitted with thermal overload protection, including cost of hardware etc on existing platform complete. pump shall have following hp rating, phase, head, minimum discharge respectively complete in all respect. oem shall have submitnabl / cpri / erda accrediatedlab type test certificate before execution. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 152 1.0 hp, 1 ø, ( 10 120 ) mtr, ( 30 12 ) lpm 153 supply , installation, testing and comissioning ofinverter type air cooled hi wall split type air conditioners with latest star rating system as per bee amended upto date complete with indoor unit ( idu ) , out door unit ( odu ) , surface / concealed copper refrigerant piping with insulation ( closed cell elastomeric nitrile rubber tubular pipe section ) upto 3 mtr ( idu to odu ) , copper power cable upto 3.5 mtr ( idu to odu ) , r 32 / r 410 green refrigerant, wireless remote control, suitable for working between 230v + / 10% with low & high voltage cutoff and50 hz , single phaseacsupply capable of performing cooling, dehumidification, air circulation of following capacity with scroll / rotary compressor. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 154 1.5 tr iseer not less then 3.8 155 providing & fixing of is : 4985 2000 class 4 ( 10 kgf / sqcm ) upvc drain water piping withfittings ( is:7834 & 10kgf / sqcm ) like elbow, socket, tee, solvent cement jointing, support with ms hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following nominal sizes. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 156 25 mm 157 supply, fixing and testing of following capacity iso certified company made wall mounted stabilizer having output voltage variation from 200 v to 250 v ( + / 5% ) with input voltage variation from 170 v to 260 v, time delay facility from 2 to 4 minute and high cutoff at 270 v with providing of 16 amp / 20 amp industrialplug top making connection etc complete in all respect.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 158 4 kva 159 making hole in stone masonary / rcc wall / rcc slab with core cutter for accomodating refrigerant pipe / drain pipe / ms pipe / cables etc of following dia 160 150 mm dia per running inch length 161 supply & fixing ms powder coated stand suitable for 1.0 / 1.5 / 2.0 tr outdoor type of split ac.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 162 supply & fixing of dry powder agent ( as per is 4308:2019 ) , abc typefire extinguisher ( stored pressure type ) conforming to is:15683:2018 , powder coated internal & external surface deep drawn cylinder body of mild steel cr2 grade conforming to is: 513, squeeze grip forged brass release valve with inbuilt safety release device, diaphragm type, 0 to 28 bar range pressure gauge, 450 mm long epdm discharge tube, qr code for product traceability including fixing on wall with suitable anchor fasteners as required of following capacity. test certificates of all the parameters along with hydro test & burst test ( for cylinder body ) certificatefrom oem / external nabl accrediated lab is to be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 163 4 kg...

Medical Health And Family Welfare - Rajasthan

36432928 electrical work in the construction of phc building at duhar chougan ( thanagazi ) distt. alwar wiring of light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked mms ( is:9537 p iii ) virgin material pvc conduit & itsisi marked ( is:3419 1988 ) accessories, round tiles, 1.2 mm thickhot dipped galvanized modular box with earth terminal, 10a modular switch, modular face plate with grid plate, 3 pin ceiling rose / holder / 3 way connector, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 3 short point ( up to 3 mtr. ) 4 medium point ( up to 6 mtr. ) 5 long point ( up to 10 mtr. ) 6 wiring of twin control light point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) in recessed isi markedmms ( is:9537 p iii ) pvc conduit & its isi marked ( is:3419 1988 ) accessories, round tiles, 2 nos hot dipped galvanized m.s modularbox of 1.2 mm thickwith earth terminal, 2 nos10 a two way modular switch, 3 pin ceiling rose / holder / 3 way connector , modular face plate with grid plate, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 7 medium point ( up to 6 mtr. ) 8 long point ( up to 10 mtr. ) 9 wiring of 3 / 5 pin 6 amp. light plug point with 1.5 sq. mm nominal sizefr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked mms ( is:9537 p iii ) pvc conduit & its isi marked ( is:3419 1988 ) accessories, hot dipped galvanizedmodular box of 1.2 mm thick with earth terminal, 10 a modularswitch, 3 / 5 pin 6 a modular socket, modular face plate with grid plate, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 10 on board 11 s&f following sizes ( dia. ) of isi marked virgin material mms ( is:9537 p iii ) pvc conduit along withisi marked ( is:3419 1988 ) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. for additional technical parameters of product / work refer annexure a attached with this bsr 12 20 mm 13 25 mm 14 32 mm 15 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from99.90 % purity copper, class 5 stranding in acc. to is:8130 / iec 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation pvc type a / c / d , flame retardant as per is 10810 53, better amperage rating as per is:3961 part 5, in existingsurface or recessed pvc / ms conduit / casing capping making connections with copper lugs of suitable size, ferrules, testing etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of product / work refer annexure a attached with this bsr 16 1 x 1.5 sq.mm 17 3x 1.5 sq.mm 18 2 x 2.5 sq. mm. + 1x1.5sqmm 19 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 20 4 x 10.0 sq.mm 21 4 x 6.0 sq.mm 22 1 x 4.0 sq.mm 23 1 x 2.5 sq.mm 24 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. 25 supplying and drawing pe insulated & pvc sheathed unarmoured telephone cable with 0.5 mm dia. solid annealed electrolytic grade bare copper conductor as per is: 8130 / 84 &confirming to tec specification gr / wir / 06 03 march 2002in existingsurface or recessed conduit / casing capping. including ferruling on each pair for identification etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 26 2 pair 27 p & f in position frame made out of m.s. angle ( riveted or welded ) finished with two coats of red oxide and two coats enamel paint including cutting, welding, holes etc.of following sizes as required.for additional technical parameters of product / work refer annexure a attached with this bsr 28 40mm x 40mm x 5mm 29 p & f paper phenolic resin bondedlaminates confirming to is : 2036 1995 for boxes / frames including making holes for switches etc, with brass screws, washers / zinc platednut and bolts as required. for additional technical parameters of product / work refer annexure a attached with this bsr 30 6.4 mm thick 31 p & f phenolic laminated sheet 2.0 mm thick of following size . including screws, cup washer as required.for additional technical parameters of product / work refer annexure a attached with this bsr 32 75 mm dia 33 providing & fixing of 240 / 415 v ac mcb with positive isolation of 10 ka breaking capacity ( b / c / d tripping characteristic as per type of load andsite requirement ) 4 kv impulse withstand voltage, isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted inexisting distribution board / sheets, minimum electrical operation 20, 000 upto 20 a rating and 10, 000 upto 63 a, 5000 for 80 a & above ratingincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 34 single pole mcb ( with b / c curve tripping characteristics ) 35 6 a to 32 a rating 36 double pole mcb ( with b / c curve tripping characteristics ) 37 6 a to 32 a rating 38 four pole mcb ( with b / c curve tripping characteristics ) 39 6 a to 32 a rating 40 50 / 63 a rating 41 providing & fixing of recessed / surface mounting heavy duty horizontal type double door ( metal / glazed ) distribution board with metal end box made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3, powder painted complete with reversible door ( for double door db only ) 100 amp. insulated copper bus bar / shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar, masking sheet, making internal db terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 42 metal door ( single phase ) ik 09 and ip 43 with metal end box 43 16 way ( 16+2 ) 44 metal door ( three phase ) ik 09 and ip 43with metal end box 45 6 way 46 p&f metal clad / plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain / bakelite base in recessed / surface mounting heavy duty enclosure made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3. powder painted ( without mcb ) including making connections, testing etc.as required.for additional technical parameters of product / work refer annexure a attached with this bsr 47 20 amp, 3 pin + scrapping earth, 4 module 48 p & f of industrial plug and socket conforming to iec 60309 1 / 2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. for additional technical parameters of product / work refer annexure a attached with this bsr 49 ip 67 panel mounted socket 50 32 a 3 pin ( 2p+e ) 51 providing & fixing of flush typenon modular single line telephone jackmade out fromindustrial grade polycarbonate or fire resistant abs material, including making connection testing etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 52 providing & fixing of ding dong / musical chime bell as per pwd specification for electrical works, including making connection testing etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 53 providing & fixing of modular type 120 w step fan regulator duly isi marked ( is 11037:1984 ) with cm / l no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , includingall as per pre approved by engineer in charge, making connections, testing etc. as required.for additional technical parameters of product / work refer annexure a attached with this bsr 54 5 step fan regulator 2 module 360 dgree rotating 55 supplying and fixing of power plug point with modular accessories as per pwd specification for electrical works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal / connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofisi marked modular 16 amp. switch ( is :3854 ) and 6 / 16 amp. socket outlet ( is:1293 ) making connection , testing , etc. as required. for specification ofwiring accessories refer chaptere 07related item & for additional technical parameters of product / work refer annexure a attached with this bsr 56 p & f krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted, including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 57 10 pairs 58 sitc of ip 42 and general construction confirming to is:8623 : 1993, wall / free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andother parameters requiredas per point ( a ) , ( b ) , ( c ) , ( d ) , ( e ) , ( f ) , ( g ) , ( h ) as below: 59 ( a ) thickness of crca sheet shallbe 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 60 ( b ) complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel.the panel having pe foam / neoprene rubber gasket of not less than 3mm thickness , required hardware , concealed hinged door with key type locking arrangement for equipment / switchgear earthed with 2.5 sq.mm braided copper wire. 61 [ c ) interconnection between bus bar and switchgears / cable shall be rigidly supported and made out by flexible copper wires ( up to 63 amp ) and by solid bus bar ( >63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only.all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgearis to be paid extra ) 62 ( d ) wiring between components within switchgear and incoming / outgoing cableshall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 63 ( e ) all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be ‘point to point’ ( no wire splitting or tee connections ) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 64 ( f ) floor mounted panel shall be mounted on base frame of ismcchannel size 100 x 50 x 5 mm ( to be paid extra ) 65 ( g ) tests: the insulation resistance ( with 1000 v megger ) and high voltage power frequency test ( by applying a voltage of 2.5kv for one minute ) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. the insulation resistance shall not be less than three megaohm. ct secondary current injection test shall also be carried out. 66 ( h ) only outer surface area on all sides shall be measured & panel to be fabricated only from cpri approved fabricator only ( cpri test certificates to be submitted ) all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 67 supplying and fixing of aluminium ( iec 60105 iso 209 1, 2 ) / copper ( iec 60028 ) bus bar by means of smc / dmc type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 68 electrolytic grade aluminium bus bar 6010 grade 69 providing & fixing of bis approvedcurrent transformeras per pwd specification for electrical works , isi marked as peris 2705 1992 / conforming to iec 60044 1, with secondary terminalof ct shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredcurrent transformer ring type tape wound / resin cast wound as per is 16227 with, accuracy cl, ct ratio and burden as specified. isf<=5, cu cross section of secondary wire 1.5sqmm ( minimum ) , including all necessary support in existing panel including connection etc. as required . all as per pre approved by engineer in charge.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 70 ring type tape wound ct 71 c t class 1, ratio 200 / 5 to 300 / 5, burden 10 va 72 providing & fixing of110 / 220 v, unibody led indicatinglamp iec 60947with integral circuit, ip 65 above panel &ip 20 terminal block, approx. body dia for panel not less then 20 mm, length min. 50mm, front led cover dia min.29 mm, contact material phospher bronze for led, pcb contacts shall be ofbrass ( tin plated ) , impulsedielectric tested for 2.5 kv, rated insulation resistance shall be 100 m ohm at 500vdcincluding connection etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 73 red / yellow / green colour 74 providing & fixing of electricalinsulating rubber matts as per pwd specification for electrical works, isi marked confirming to is: 15652 / 2006with one sideanti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 75 3.3 kv, class a 2 mm thick with proof voltage 10 kv ac ( rms ) and break down voltage 30 kv ac ( rms ) 76 sitc of3 / 4pole current limiting moulded case circuit breaker ( mccb ) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440 / 415 v, 50 hz; o / l & s / c settings , conforming to is / iec 60947 p 2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push ( test ) to trip, trip time less then 10 ms under s / c condition, breaking capacity ics = 100% icu. u imp =8 kv, rated insulation voltage690 v.provision for uvr , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.oem shall have submitnabl / cpri / erda accrediated lab type test certificate before execution all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 77 4 pole mccb with thermal magnetic release 78 125 amp , 25 ka, adjustable o / l & adjustable s / c setting, 79 up to 100 amp , 25 ka, adjustable o / l & adjustable s / c setting, 80 providing & fixing of iso certified company made on load change over switch, front handle operated, four pole 415 v as per pwd specificationfor electrical works conforming to is / lec 60947 3 : 1999 including connections , testing etc. as required .in the following rating.appropriate type test certificate / oem test report shall be submitted .all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 81 open execution type 82 160 a 83 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed arrmouredaluminiumcable confirming to is:1554 p i / is :7098 p i of 1.1 kv withh4 grade electrolyticaluminium conductor confirming to is 8130 of purity >99.6 %, round / flat strip armouring of cables, inner / outer sheath confirming to is:5831in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench / cable tray ( with cable tie ) includingtesting etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810.for additional technical parameters of product / work refer annexure a attached with this bsr 84 10.0 sq. mm 85 2 core 86 35.0 sq. mm 87 3.5 core 88 supplying and making one end termination with nickel plated heavy duty brass single compression gland ( as per is 12943 1990 ) ) sibg type consisting of check nut, gland body, metal washer ( 3 nos. ) , outer seal rubber ring, compression nut, heavy duty aluminium lugs ( as per is 8309 1993 ) duly crimped with crimping tool, pvc tape as peris 8337 1976offollowing size ofpvc insulated & pvc sheathed / xlpe aluminium conductor cable of 1100 volt grade as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 89 3.5 x 35.0 sq.mm 90 supplying and makingend termination with heavy aluminiumlugs ( pin / ring type ) confirming to is 8309 1993 & is 8337 1976 duly crimped with crimping tool, pvc tape etc of following size.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 91 35.0 sq.mm 92 supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % copperthickness ( 250 microns ) andconfirming toul 467, is / iec 62561 2of following size and length and as per point mentioned ( a ) , ( b ) , [ c ) , ( d ) , ( e ) below : 93 ( a ) bore a hole of dia. 100 mm of required length, place the rod in the centre of hole 94 ( b ) filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, cpri / erdatested with rms capacity of minimum 30 ka for withstanding 1 second .to ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. the compound shall be tested form nabl acredeated labfor lowresistivity ( less than 0.12 ohm meter ) & high conductivity in nature with carbon as a major contentas per referance of is 3043 1987, ieee 80 2013 ( clause 14.5d ) , ieee 837 & ier 1956 with latest amendemnts 95 © connect the rod with copper strip / conductor / wire with suitable clamp made from tinned copper and ss 304 bolt 96 ( d ) place heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height250 to 300 mm. 97 ( d ) testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 98 ( e ) test certificatesfor confirming above standards from oem is mandatory. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 99 17.2 mm thick and 3 mtr. long 100 supply & laying following size earth wire in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection with gi / cu purity purity >95%thimble etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 101 8 swg copper wire 102 8 swg g.i. ( hot dipped ) wire 103 making of hole in wall ( brick / stone ) of required and placing np 2 rcc pipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 104 up to 457 mm size 105 providing & fixing ofbeestar rated copper wounded double ball bearing capacitor start, aluminium body & metallicblade ceilingfanconforming to all the performance requirements laid down in is 374:2019 including all amendments, as applicable ; & carry bis licensing ( i.e. isi marking ) with down rod up to 80 cm with secondary support safety cable ( steel rope ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 106 1200 mm sweep bee 2 star rated ( service value >=4.5 to < 5 ) 107 1200 mm sweep bee 3 star rated ( service value >=5.0 to< 5.5 ) 108 p & f 1.2mm thickm.s. recessed fan box, hexagonal / round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mmlength extended on each side . all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr 109 p & f 1.2mm thickm.s. recessed fan box, hexagonal / round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mmlength extended on each side . all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr 110 providing & fixing ofof double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor , making connections, testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 111 225 mm sweep 112 providing & fixing of heavy duty capacitor start, copper wounddouble ball bearing900 / 1400 rpm single phaseexhaustfan conforming to is:2312 isi marked in existing opening including making connections testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 113 300 mm sweep ( 900 / 1400 rpm ) 114 providing & fixing of wall mounting / pedestal type heavy duty air circulator , double ball bearing and with metal sturdy mesh guard; aluminium alloy one piece blade and conforming to is:2997, including fixing with anchor bolts, making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 115 450 mm sweep wall mounting and three speed regulator with minimum air delivery 150 cum. / minute 116 p & f of gravity louver shutter of superior quality made out of frame of18 swg m.s. sheet & louvers made from 24 swg ms sheetwith enamel paint including cost of nuts, bolts, etc as reqd.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 117 up to 380 mm size 118 providing & fixing of vertical ( bee 5 star rated ) / horizontal ( bee 3 star rated ) storage water heater with outer casing made of engineering plastic sheet ( upto 25 ltr ) / metal rust proof body ( 35 & 50 ltr ) , glass line / titanium enamel coated pressure pump compatible 8 bar pressure inner tank, glass line coated , mineral filled heating element, stem type, snap actionadjustable thermostat , dual indicating lampsinjected puf insulation, multi function valve etc. as required held in position with 2 / 4 no. 10 / 12 mm anchor fastener, duly wired with 3 core 2.5 / 4.0 sqmm pvc insulated & sheathed copper conductor and 16 a / 25a three pin plug top with portable residual current device ( prcd ) , including making inlet, outlet flexible alloyconnection, testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 119 15 ltr. 120 sitc ofmnre approved & confirming to is:12933 p 1, 2, 3 & 5 flat plate collector type solar hot water system havingcollector withzincalum sheet outer body , glass line / titanium enamel coated inner tank with metal rust proof puf insulated body includingelectrical back up, thermostat, powder coated / hot dipped galvanized ms standfor collector & tank etc. as required. of following capacity complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 121 200 litre / day 122 providing & fixing of energy efficient direct fit ( retrofit ) polycarbonate / glasshousingsmd mid power led tube rod ( with integral driver & alumn. heat sink ) , on existing fixture.system lumen efficacy = 100 lm / watt output, internal surge protection of 2.5 kv , thd < 20% , p.f.=0.95, cri >80 , life time of minimum35000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 123 1200mm , min. lumens output 2000 lmled tube rod with polycarbonate housing 124 providing & fixing of ip 20 led recessed / surface mounted, round / sqauresmd mid power led downlight with power coated die cast aluminum housingwith uv stabilized non yellowish diffuser withbis complience 2.5 kv surge protected isolated driver, with short & open circuit protection, having efficiency > 85% . system lumen efficacy of = 110 lm / watt, thd < 10 % , pf.=0.95, cri >80, life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. 125 oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 126 surface mounting ( with extruded alumn. housing ) 127 minimum lumen output 1950 lm 128 providing & fixing of ip20, 2x2 led surface / recessedmounting mid power smd type led light fixture not less than 50mm housing depth made from crca sheet steel housing, high purity / transmisivity uv stabilized non yellowish diffuser for uniform light distribution. high efficiency with 4 kv internal / external surge protection bis certified isolated driver having efficiency > 85% , with short & open circuit protection ( integral with light fixture ) . system lumen efficacy of = 120 lm / watt , thd < 10 % , p.f.=0.95, cri >80 , life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. 129 oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 130 recessed mounting 131 minimum lumen output 4200 lm 132 providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket / pole. fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with uv stabilized pc ( uv stablization report submitted for uv cover ) / toughened glass coverand secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm / wt and potted driver& has a unique bis r number withinput voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driverefficiency >85%, thd ( i ) <10%humidity 10% to 90% rh working temp 5c to 45c .driver current <750ma. the luminaireshall be bis certified and trade mark certified. life expectancyequal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min = 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs.manufactures word mark / name engraved / embossing on die cast housing to allow traceability / authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities forled fixtures. ( lm79 / lm80 ) certificate / report with liable warranty of product / accessories from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 133 led street light fixture with minimum lumen output 2450 lm 134 providing & fixing of street light bracket made out from following size of b class , medium class g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with heavy duty pole clamp, saddles suitable fastners etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 135 25 mm dia. 136 supply, drawing and testing of 4 pair, 23 awg solid bare copper wire insulated with pvc, utp ( unshielded twisted pair ) , category 6, class e, 100 ohm impedance, indoor cable as per latest ammendments of ansi / tia / eia 568 , the copper conductors should be balanced twisted in pairs, seperated by a cross member fluted pair divider & protected bypvc jacket. certified performance in a 4 connector configuration upto 100 mtrs channel requirements & transmission frequencies up to 250 mhz. in existing ms / pvc conduits / casing capping including making connections to information outlets and patch panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 137 supply and installation of unsheilded / 360 degree sheilded information outlets made of high impact plastic body with abs, fr grade halogen free material with provision for protection against dust in jack, suitable for cat 6 / 6a application complying to latest ammendments, according. to cat. 6 / 6a channel, it should support channel as well as components requirements of cat.6 / 6a standards at frequencies of up to 250 to 500 mhz. cat 6 / 6a unshielded / shielded jack should be suitable to terminate 4 pair, 23 / 24 awg solid / stranded wire diameters, using 100 ohm unshielded / shielded balance twisted pair cable, the jack should have tooless / impact termination on reliable copper tin plated insulation displacement contact, with easy lock mechanism, it supports iec 60603 7 4 and complied with ansi / tia / eia 568 c.2 standard. jack should be rj11, rj12 & rj45 compatible. should support ethernet 1.2 gb / s atm, digital video and broadband / baseband analog video, voice over internet protocal ( voip ) specifications in existing modular / ms boxes along with necessory connections as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 138 cat 6, un sheilded information outlet 139 supply & fixing of square faceplate for flush / surface mount information outlets single / dual or quad aperture , material should bepc+abs body, suitable for rj45 unshielded / shielded connection modules. should match with i. o. oem. dimensions should be 86mm x 86mm as required complete in all respect.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 140 single aperture 141 supply , installation and testing of 4 pair, 100 ohm impedance, cat 6 / 6a / class e / ea patch cords should be constructed of minimum 23 / 24 awg, stranded bare copper cable with frpvc / lszh jacket, with an enhanced performance by factory moulded rj45 connectors with strain relief boots as per ansi / tia / eia 568 c.2 suitable for cat 6 / 6a application complying to latest ammendments category 6 / 6a standards, according. to tia568c.2, iso / iec 11801, en 50173, iec 60603 7 51, en 60603 7, ieee 802.3an minimum requirement for 1g base t to 10g base t performance. patch cords shall be straight thru cable compatible with both t568 a and t568 b wiring schemes, should support ieee 802.3af / ieee 802.3at for poe applications, minimum 750 to 1000 mating cycles in plug contacts for long durability, should support ethernet 10gbase t, 1.2 gb / s atm, token ring 4 / 16, digital video and broadband / baseband analog video, voice over internet protocal ( voip ) .all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 142 cat 6, u / utp ( unscreened / un sheilded twisted pair ) patch cord 143 1 mtr 144 supply, installation, & testing of 19 1u rack mounted / surface mounted aluminum / crca 1.2mm powder coated, multimode glass fiber optic cable patch panel / liu loaded with flangless / screwable adapters for st / e 2000 / sc / lc / mt rj / pc type, it should have easy removable top plate with push buttons, there should be a splice tray installed in the patch panel / liu which can handle the fiber cores, splice tray should be pc+abs material, it should include accessories like mounting hardware, gormetts, heat shrink tubes / sleevs, screws, nuts to install the panel for rack / wallmount applications as per requirement complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 145 multi mode liu 12 ports 146 supply & installation of ip 20 & ik 08 , ul listedwall mounted double section communication enclosure ( rack ) made from powder coated ( 60 to 80 micron ) crca sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door, vertical mounting rail 1.6 mm with umarking , with all round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. accessories like: 1 no of 19 1u horizontal cable manager, 1 no of 90 cfm 230v ac fan with 1 mts long cable, mounting hardware , 1 no of 19 1u, mountable socket strips with 5 nos of 5a universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with suitable anchor fastneretc as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 147 6 u rack with width 600 mm &depth 400 mm + 100 mm 148 supply , installation, testing and comissioning ofmanaged layer 2 intelligent 10 / 100 ethernet switch providing 24 x 10 / 100 / 1000 mbps giga ethernet ports / with min 2 sfp giga ports ( provision for fiber giga connectivity ) with related lan base software including making connections etc as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 149 sitc of single stage, water cooled, high speed ( 2880 rpm ) , horizontal, centrifugal, openwell submersible pumps set pre filled with coolent water and fitted with mechanical seal t / c vs t / c, thrust bearing shall be ofcarbon + s.s.the stator body of single phase pumpshall be of ss and rest of all shall be of cast iron. all casting parts should be cathod electro deposition ( ced ) coated and other construction material should be confirming to is : 14220: 2018 . the overall performance of pump shall confirm to bee energy efficiency level of 3 star. valid bee certificate from oem must be submitted for the same. motor should be ie2 class as per iec 60034 2 1: 2007, iec 60034 30: 2008, & is12615:2011, including making connection etc as required complete in all respect. oem shall have submitnabl / cpri / erda accrediatedlab type test certificate before execution. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 150 1.0 hp, 1 ø, ( 7 12 ) mtr, ( 405 240 ) lpm 151 sitc of monoblock motor pump set isi marked ( is:9079 2002 ) with tefc motor, motor should be ie2 class as per iec 60034 2 1: 2007, iec 60034 30: 2008, & is12615:2011. with stainless steel impellor, stainless steel shaft, mechanical seal, single / three phase ( 240 440 v ) permanent split capacitor type ( psc ) , fitted with thermal overload protection, including cost of hardware etc on existing platform complete. pump shall have following hp rating, phase, head, minimum discharge respectively complete in all respect. oem shall have submitnabl / cpri / erda accrediatedlab type test certificate before execution. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 152 1.0 hp, 1 ø, ( 10 120 ) mtr, ( 30 12 ) lpm 153 supply , installation, testing and comissioning ofinverter type air cooled hi wall split type air conditioners with latest star rating system as per bee amended upto date complete with indoor unit ( idu ) , out door unit ( odu ) , surface / concealed copper refrigerant piping with insulation ( closed cell elastomeric nitrile rubber tubular pipe section ) upto 3 mtr ( idu to odu ) , copper power cable upto 3.5 mtr ( idu to odu ) , r 32 / r 410 green refrigerant, wireless remote control, suitable for working between 230v + / 10% with low & high voltage cutoff and50 hz , single phaseacsupply capable of performing cooling, dehumidification, air circulation of following capacity with scroll / rotary compressor. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 154 1.5 tr iseer not less then 3.8 155 providing & fixing of is : 4985 2000 class 4 ( 10 kgf / sqcm ) upvc drain water piping withfittings ( is:7834 & 10kgf / sqcm ) like elbow, socket, tee, solvent cement jointing, support with ms hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following nominal sizes. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 156 25 mm 157 supply, fixing and testing of following capacity iso certified company made wall mounted stabilizer having output voltage variation from 200 v to 250 v ( + / 5% ) with input voltage variation from 170 v to 260 v, time delay facility from 2 to 4 minute and high cutoff at 270 v with providing of 16 amp / 20 amp industrialplug top making connection etc complete in all respect.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 158 4 kva 159 making hole in stone masonary / rcc wall / rcc slab with core cutter for accomodating refrigerant pipe / drain pipe / ms pipe / cables etc of following dia 160 150 mm dia per running inch length 161 supply & fixing ms powder coated stand suitable for 1.0 / 1.5 / 2.0 tr outdoor type of split ac.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 162 supply & fixing of dry powder agent ( as per is 4308:2019 ) , abc typefire extinguisher ( stored pressure type ) conforming to is:15683:2018 , powder coated internal & external surface deep drawn cylinder body of mild steel cr2 grade conforming to is: 513, squeeze grip forged brass release valve with inbuilt safety release device, diaphragm type, 0 to 28 bar range pressure gauge, 450 mm long epdm discharge tube, qr code for product traceability including fixing on wall with suitable anchor fasteners as required of following capacity. test certificates of all the parameters along with hydro test & burst test ( for cylinder body ) certificatefrom oem / external nabl accrediated lab is to be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 163 4 kg...

Medical Health And Family Welfare - Rajasthan

36432910 tender for electrical work in the construction of phc building at basai jogiyan ( thangagazi ) distt. alwar wiring of light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked mms ( is:9537 p iii ) virgin material pvc conduit & itsisi marked ( is:3419 1988 ) accessories, round tiles, 1.2 mm thickhot dipped galvanized modular box with earth terminal, 10a modular switch, modular face plate with grid plate, 3 pin ceiling rose / holder / 3 way connector, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 3 short point ( up to 3 mtr. ) 4 medium point ( up to 6 mtr. ) 5 long point ( up to 10 mtr. ) 6 wiring of twin control light point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) in recessed isi markedmms ( is:9537 p iii ) pvc conduit & its isi marked ( is:3419 1988 ) accessories, round tiles, 2 nos hot dipped galvanized m.s modularbox of 1.2 mm thickwith earth terminal, 2 nos10 a two way modular switch, 3 pin ceiling rose / holder / 3 way connector , modular face plate with grid plate, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 7 medium point ( up to 6 mtr. ) 8 long point ( up to 10 mtr. ) 9 wiring of 3 / 5 pin 6 amp. light plug point with 1.5 sq. mm nominal sizefr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked mms ( is:9537 p iii ) pvc conduit & its isi marked ( is:3419 1988 ) accessories, hot dipped galvanizedmodular box of 1.2 mm thick with earth terminal, 10 a modularswitch, 3 / 5 pin 6 a modular socket, modular face plate with grid plate, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 10 on board 11 s&f following sizes ( dia. ) of isi marked virgin material mms ( is:9537 p iii ) pvc conduit along withisi marked ( is:3419 1988 ) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. for additional technical parameters of product / work refer annexure a attached with this bsr 12 20 mm 13 25 mm 14 32 mm 15 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from99.90 % purity copper, class 5 stranding in acc. to is:8130 / iec 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation pvc type a / c / d , flame retardant as per is 10810 53, better amperage rating as per is:3961 part 5, in existingsurface or recessed pvc / ms conduit / casing capping making connections with copper lugs of suitable size, ferrules, testing etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of product / work refer annexure a attached with this bsr 16 1 x 1.5 sq.mm 17 3x 1.5 sq.mm 18 2 x 2.5 sq. mm. + 1x1.5sqmm 19 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 20 4 x 10.0 sq.mm 21 4 x 6.0 sq.mm 22 1 x 4.0 sq.mm 23 1 x 2.5 sq.mm 24 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. 25 supplying and drawing pe insulated & pvc sheathed unarmoured telephone cable with 0.5 mm dia. solid annealed electrolytic grade bare copper conductor as per is: 8130 / 84 &confirming to tec specification gr / wir / 06 03 march 2002in existingsurface or recessed conduit / casing capping. including ferruling on each pair for identification etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 26 2 pair 27 p & f in position frame made out of m.s. angle ( riveted or welded ) finished with two coats of red oxide and two coats enamel paint including cutting, welding, holes etc.of following sizes as required.for additional technical parameters of product / work refer annexure a attached with this bsr 28 40mm x 40mm x 5mm 29 p & f paper phenolic resin bondedlaminates confirming to is : 2036 1995 for boxes / frames including making holes for switches etc, with brass screws, washers / zinc platednut and bolts as required. for additional technical parameters of product / work refer annexure a attached with this bsr 30 6.4 mm thick 31 p & f phenolic laminated sheet 2.0 mm thick of following size . including screws, cup washer as required.for additional technical parameters of product / work refer annexure a attached with this bsr 32 75 mm dia 33 providing & fixing of 240 / 415 v ac mcb with positive isolation of 10 ka breaking capacity ( b / c / d tripping characteristic as per type of load andsite requirement ) 4 kv impulse withstand voltage, isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted inexisting distribution board / sheets, minimum electrical operation 20, 000 upto 20 a rating and 10, 000 upto 63 a, 5000 for 80 a & above ratingincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 34 single pole mcb ( with b / c curve tripping characteristics ) 35 6 a to 32 a rating 36 double pole mcb ( with b / c curve tripping characteristics ) 37 6 a to 32 a rating 38 four pole mcb ( with b / c curve tripping characteristics ) 39 6 a to 32 a rating 40 50 / 63 a rating 41 providing & fixing of recessed / surface mounting heavy duty horizontal type double door ( metal / glazed ) distribution board with metal end box made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3, powder painted complete with reversible door ( for double door db only ) 100 amp. insulated copper bus bar / shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar, masking sheet, making internal db terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 42 metal door ( single phase ) ik 09 and ip 43 with metal end box 43 16 way ( 16+2 ) 44 metal door ( three phase ) ik 09 and ip 43with metal end box 45 6 way 46 p&f metal clad / plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain / bakelite base in recessed / surface mounting heavy duty enclosure made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3. powder painted ( without mcb ) including making connections, testing etc.as required.for additional technical parameters of product / work refer annexure a attached with this bsr 47 20 amp, 3 pin + scrapping earth, 4 module 48 p & f of industrial plug and socket conforming to iec 60309 1 / 2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. for additional technical parameters of product / work refer annexure a attached with this bsr 49 ip 67 panel mounted socket 50 32 a 3 pin ( 2p+e ) 51 providing & fixing of flush typenon modular single line telephone jackmade out fromindustrial grade polycarbonate or fire resistant abs material, including making connection testing etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 52 providing & fixing of ding dong / musical chime bell as per pwd specification for electrical works, including making connection testing etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 53 providing & fixing of modular type 120 w step fan regulator duly isi marked ( is 11037:1984 ) with cm / l no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , includingall as per pre approved by engineer in charge, making connections, testing etc. as required.for additional technical parameters of product / work refer annexure a attached with this bsr 54 5 step fan regulator 2 module 360 dgree rotating 55 supplying and fixing of power plug point with modular accessories as per pwd specification for electrical works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal / connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofisi marked modular 16 amp. switch ( is :3854 ) and 6 / 16 amp. socket outlet ( is:1293 ) making connection , testing , etc. as required. for specification ofwiring accessories refer chaptere 07related item & for additional technical parameters of product / work refer annexure a attached with this bsr 56 p & f krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted, including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 57 10 pairs 58 sitc of ip 42 and general construction confirming to is:8623 : 1993, wall / free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andother parameters requiredas per point ( a ) , ( b ) , ( c ) , ( d ) , ( e ) , ( f ) , ( g ) , ( h ) as below: 59 ( a ) thickness of crca sheet shallbe 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 60 ( b ) complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel.the panel having pe foam / neoprene rubber gasket of not less than 3mm thickness , required hardware , concealed hinged door with key type locking arrangement for equipment / switchgear earthed with 2.5 sq.mm braided copper wire. 61 [ c ) interconnection between bus bar and switchgears / cable shall be rigidly supported and made out by flexible copper wires ( up to 63 amp ) and by solid bus bar ( >63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only.all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgearis to be paid extra ) 62 ( d ) wiring between components within switchgear and incoming / outgoing cableshall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 63 ( e ) all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be ‘point to point’ ( no wire splitting or tee connections ) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 64 ( f ) floor mounted panel shall be mounted on base frame of ismcchannel size 100 x 50 x 5 mm ( to be paid extra ) 65 ( g ) tests: the insulation resistance ( with 1000 v megger ) and high voltage power frequency test ( by applying a voltage of 2.5kv for one minute ) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. the insulation resistance shall not be less than three megaohm. ct secondary current injection test shall also be carried out. 66 ( h ) only outer surface area on all sides shall be measured & panel to be fabricated only from cpri approved fabricator only ( cpri test certificates to be submitted ) all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 67 supplying and fixing of aluminium ( iec 60105 iso 209 1, 2 ) / copper ( iec 60028 ) bus bar by means of smc / dmc type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 68 electrolytic grade aluminium bus bar 6010 grade 69 providing & fixing of bis approvedcurrent transformeras per pwd specification for electrical works , isi marked as peris 2705 1992 / conforming to iec 60044 1, with secondary terminalof ct shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredcurrent transformer ring type tape wound / resin cast wound as per is 16227 with, accuracy cl, ct ratio and burden as specified. isf<=5, cu cross section of secondary wire 1.5sqmm ( minimum ) , including all necessary support in existing panel including connection etc. as required . all as per pre approved by engineer in charge.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 70 ring type tape wound ct 71 c t class 1, ratio 200 / 5 to 300 / 5, burden 10 va 72 providing & fixing of110 / 220 v, unibody led indicatinglamp iec 60947with integral circuit, ip 65 above panel &ip 20 terminal block, approx. body dia for panel not less then 20 mm, length min. 50mm, front led cover dia min.29 mm, contact material phospher bronze for led, pcb contacts shall be ofbrass ( tin plated ) , impulsedielectric tested for 2.5 kv, rated insulation resistance shall be 100 m ohm at 500vdcincluding connection etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 73 red / yellow / green colour 74 providing & fixing of electricalinsulating rubber matts as per pwd specification for electrical works, isi marked confirming to is: 15652 / 2006with one sideanti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 75 3.3 kv, class a 2 mm thick with proof voltage 10 kv ac ( rms ) and break down voltage 30 kv ac ( rms ) 76 sitc of3 / 4pole current limiting moulded case circuit breaker ( mccb ) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440 / 415 v, 50 hz; o / l & s / c settings , conforming to is / iec 60947 p 2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push ( test ) to trip, trip time less then 10 ms under s / c condition, breaking capacity ics = 100% icu. u imp =8 kv, rated insulation voltage690 v.provision for uvr , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.oem shall have submitnabl / cpri / erda accrediated lab type test certificate before execution all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 77 4 pole mccb with thermal magnetic release 78 125 amp , 25 ka, adjustable o / l & adjustable s / c setting, 79 up to 100 amp , 25 ka, adjustable o / l & adjustable s / c setting, 80 providing & fixing of iso certified company made on load change over switch, front handle operated, four pole 415 v as per pwd specificationfor electrical works conforming to is / lec 60947 3 : 1999 including connections , testing etc. as required .in the following rating.appropriate type test certificate / oem test report shall be submitted .all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 81 open execution type 82 160 a 83 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed arrmouredaluminiumcable confirming to is:1554 p i / is :7098 p i of 1.1 kv withh4 grade electrolyticaluminium conductor confirming to is 8130 of purity >99.6 %, round / flat strip armouring of cables, inner / outer sheath confirming to is:5831in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench / cable tray ( with cable tie ) includingtesting etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810.for additional technical parameters of product / work refer annexure a attached with this bsr 84 10.0 sq. mm 85 2 core 86 35.0 sq. mm 87 3.5 core 88 supplying and making one end termination with nickel plated heavy duty brass single compression gland ( as per is 12943 1990 ) ) sibg type consisting of check nut, gland body, metal washer ( 3 nos. ) , outer seal rubber ring, compression nut, heavy duty aluminium lugs ( as per is 8309 1993 ) duly crimped with crimping tool, pvc tape as peris 8337 1976offollowing size ofpvc insulated & pvc sheathed / xlpe aluminium conductor cable of 1100 volt grade as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 89 3.5 x 35.0 sq.mm 90 supplying and makingend termination with heavy aluminiumlugs ( pin / ring type ) confirming to is 8309 1993 & is 8337 1976 duly crimped with crimping tool, pvc tape etc of following size.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 91 35.0 sq.mm 92 supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % copperthickness ( 250 microns ) andconfirming toul 467, is / iec 62561 2of following size and length and as per point mentioned ( a ) , ( b ) , [ c ) , ( d ) , ( e ) below : 93 ( a ) bore a hole of dia. 100 mm of required length, place the rod in the centre of hole 94 ( b ) filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, cpri / erdatested with rms capacity of minimum 30 ka for withstanding 1 second .to ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. the compound shall be tested form nabl acredeated labfor lowresistivity ( less than 0.12 ohm meter ) & high conductivity in nature with carbon as a major contentas per referance of is 3043 1987, ieee 80 2013 ( clause 14.5d ) , ieee 837 & ier 1956 with latest amendemnts 95 © connect the rod with copper strip / conductor / wire with suitable clamp made from tinned copper and ss 304 bolt 96 ( d ) place heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height250 to 300 mm. 97 ( d ) testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 98 ( e ) test certificatesfor confirming above standards from oem is mandatory. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 99 17.2 mm thick and 3 mtr. long 100 supply & laying following size earth wire in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection with gi / cu purity purity >95%thimble etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 101 8 swg copper wire 102 8 swg g.i. ( hot dipped ) wire 103 making of hole in wall ( brick / stone ) of required and placing np 2 rcc pipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 104 up to 457 mm size 105 providing & fixing ofbeestar rated copper wounded double ball bearing capacitor start, aluminium body & metallicblade ceilingfanconforming to all the performance requirements laid down in is 374:2019 including all amendments, as applicable ; & carry bis licensing ( i.e. isi marking ) with down rod up to 80 cm with secondary support safety cable ( steel rope ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 106 1200 mm sweep bee 2 star rated ( service value >=4.5 to < 5 ) 107 1200 mm sweep bee 3 star rated ( service value >=5.0 to< 5.5 ) 108 p & f 1.2mm thickm.s. recessed fan box, hexagonal / round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mmlength extended on each side . all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr 109 p & f 1.2mm thickm.s. recessed fan box, hexagonal / round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mmlength extended on each side . all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr 110 providing & fixing ofof double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor , making connections, testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 111 225 mm sweep 112 providing & fixing of heavy duty capacitor start, copper wounddouble ball bearing900 / 1400 rpm single phaseexhaustfan conforming to is:2312 isi marked in existing opening including making connections testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 113 300 mm sweep ( 900 / 1400 rpm ) 114 providing & fixing of wall mounting / pedestal type heavy duty air circulator , double ball bearing and with metal sturdy mesh guard; aluminium alloy one piece blade and conforming to is:2997, including fixing with anchor bolts, making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 115 450 mm sweep wall mounting and three speed regulator with minimum air delivery 150 cum. / minute 116 p & f of gravity louver shutter of superior quality made out of frame of18 swg m.s. sheet & louvers made from 24 swg ms sheetwith enamel paint including cost of nuts, bolts, etc as reqd.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 117 up to 380 mm size 118 providing & fixing of vertical ( bee 5 star rated ) / horizontal ( bee 3 star rated ) storage water heater with outer casing made of engineering plastic sheet ( upto 25 ltr ) / metal rust proof body ( 35 & 50 ltr ) , glass line / titanium enamel coated pressure pump compatible 8 bar pressure inner tank, glass line coated , mineral filled heating element, stem type, snap actionadjustable thermostat , dual indicating lampsinjected puf insulation, multi function valve etc. as required held in position with 2 / 4 no. 10 / 12 mm anchor fastener, duly wired with 3 core 2.5 / 4.0 sqmm pvc insulated & sheathed copper conductor and 16 a / 25a three pin plug top with portable residual current device ( prcd ) , including making inlet, outlet flexible alloyconnection, testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 119 15 ltr. 120 sitc ofmnre approved & confirming to is:12933 p 1, 2, 3 & 5 flat plate collector type solar hot water system havingcollector withzincalum sheet outer body , glass line / titanium enamel coated inner tank with metal rust proof puf insulated body includingelectrical back up, thermostat, powder coated / hot dipped galvanized ms standfor collector & tank etc. as required. of following capacity complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 121 200 litre / day 122 providing & fixing of energy efficient direct fit ( retrofit ) polycarbonate / glasshousingsmd mid power led tube rod ( with integral driver & alumn. heat sink ) , on existing fixture.system lumen efficacy = 100 lm / watt output, internal surge protection of 2.5 kv , thd < 20% , p.f.=0.95, cri >80 , life time of minimum35000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 123 1200mm , min. lumens output 2000 lmled tube rod with polycarbonate housing 124 providing & fixing of ip 20 led recessed / surface mounted, round / sqauresmd mid power led downlight with power coated die cast aluminum housingwith uv stabilized non yellowish diffuser withbis complience 2.5 kv surge protected isolated driver, with short & open circuit protection, having efficiency > 85% . system lumen efficacy of = 110 lm / watt, thd < 10 % , pf.=0.95, cri >80, life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. 125 oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 126 surface mounting ( with extruded alumn. housing ) 127 minimum lumen output 1950 lm 128 providing & fixing of ip20, 2x2 led surface / recessedmounting mid power smd type led light fixture not less than 50mm housing depth made from crca sheet steel housing, high purity / transmisivity uv stabilized non yellowish diffuser for uniform light distribution. high efficiency with 4 kv internal / external surge protection bis certified isolated driver having efficiency > 85% , with short & open circuit protection ( integral with light fixture ) . system lumen efficacy of = 120 lm / watt , thd < 10 % , p.f.=0.95, cri >80 , life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. 129 oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 130 recessed mounting 131 minimum lumen output 4200 lm 132 providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket / pole. fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with uv stabilized pc ( uv stablization report submitted for uv cover ) / toughened glass coverand secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm / wt and potted driver& has a unique bis r number withinput voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driverefficiency >85%, thd ( i ) <10%humidity 10% to 90% rh working temp 5c to 45c .driver current <750ma. the luminaireshall be bis certified and trade mark certified. life expectancyequal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min = 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs.manufactures word mark / name engraved / embossing on die cast housing to allow traceability / authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities forled fixtures. ( lm79 / lm80 ) certificate / report with liable warranty of product / accessories from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 133 led street light fixture with minimum lumen output 2450 lm 134 providing & fixing of street light bracket made out from following size of b class , medium class g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with heavy duty pole clamp, saddles suitable fastners etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 135 25 mm dia. 136 supply, drawing and testing of 4 pair, 23 awg solid bare copper wire insulated with pvc, utp ( unshielded twisted pair ) , category 6, class e, 100 ohm impedance, indoor cable as per latest ammendments of ansi / tia / eia 568 , the copper conductors should be balanced twisted in pairs, seperated by a cross member fluted pair divider & protected bypvc jacket. certified performance in a 4 connector configuration upto 100 mtrs channel requirements & transmission frequencies up to 250 mhz. in existing ms / pvc conduits / casing capping including making connections to information outlets and patch panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 137 supply and installation of unsheilded / 360 degree sheilded information outlets made of high impact plastic body with abs, fr grade halogen free material with provision for protection against dust in jack, suitable for cat 6 / 6a application complying to latest ammendments, according. to cat. 6 / 6a channel, it should support channel as well as components requirements of cat.6 / 6a standards at frequencies of up to 250 to 500 mhz. cat 6 / 6a unshielded / shielded jack should be suitable to terminate 4 pair, 23 / 24 awg solid / stranded wire diameters, using 100 ohm unshielded / shielded balance twisted pair cable, the jack should have tooless / impact termination on reliable copper tin plated insulation displacement contact, with easy lock mechanism, it supports iec 60603 7 4 and complied with ansi / tia / eia 568 c.2 standard. jack should be rj11, rj12 & rj45 compatible. should support ethernet 1.2 gb / s atm, digital video and broadband / baseband analog video, voice over internet protocal ( voip ) specifications in existing modular / ms boxes along with necessory connections as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 138 cat 6, un sheilded information outlet 139 supply & fixing of square faceplate for flush / surface mount information outlets single / dual or quad aperture , material should bepc+abs body, suitable for rj45 unshielded / shielded connection modules. should match with i. o. oem. dimensions should be 86mm x 86mm as required complete in all respect.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 140 single aperture 141 supply , installation and testing of 4 pair, 100 ohm impedance, cat 6 / 6a / class e / ea patch cords should be constructed of minimum 23 / 24 awg, stranded bare copper cable with frpvc / lszh jacket, with an enhanced performance by factory moulded rj45 connectors with strain relief boots as per ansi / tia / eia 568 c.2 suitable for cat 6 / 6a application complying to latest ammendments category 6 / 6a standards, according. to tia568c.2, iso / iec 11801, en 50173, iec 60603 7 51, en 60603 7, ieee 802.3an minimum requirement for 1g base t to 10g base t performance. patch cords shall be straight thru cable compatible with both t568 a and t568 b wiring schemes, should support ieee 802.3af / ieee 802.3at for poe applications, minimum 750 to 1000 mating cycles in plug contacts for long durability, should support ethernet 10gbase t, 1.2 gb / s atm, token ring 4 / 16, digital video and broadband / baseband analog video, voice over internet protocal ( voip ) .all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 142 cat 6, u / utp ( unscreened / un sheilded twisted pair ) patch cord 143 1 mtr 144 supply, installation, & testing of 19 1u rack mounted / surface mounted aluminum / crca 1.2mm powder coated, multimode glass fiber optic cable patch panel / liu loaded with flangless / screwable adapters for st / e 2000 / sc / lc / mt rj / pc type, it should have easy removable top plate with push buttons, there should be a splice tray installed in the patch panel / liu which can handle the fiber cores, splice tray should be pc+abs material, it should include accessories like mounting hardware, gormetts, heat shrink tubes / sleevs, screws, nuts to install the panel for rack / wallmount applications as per requirement complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 145 multi mode liu 12 ports 146 supply & installation of ip 20 & ik 08 , ul listedwall mounted double section communication enclosure ( rack ) made from powder coated ( 60 to 80 micron ) crca sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door, vertical mounting rail 1.6 mm with umarking , with all round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. accessories like: 1 no of 19 1u horizontal cable manager, 1 no of 90 cfm 230v ac fan with 1 mts long cable, mounting hardware , 1 no of 19 1u, mountable socket strips with 5 nos of 5a universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with suitable anchor fastneretc as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 147 6 u rack with width 600 mm &depth 400 mm + 100 mm 148 supply , installation, testing and comissioning ofmanaged layer 2 intelligent 10 / 100 ethernet switch providing 24 x 10 / 100 / 1000 mbps giga ethernet ports / with min 2 sfp giga ports ( provision for fiber giga connectivity ) with related lan base software including making connections etc as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 149 sitc of single stage, water cooled, high speed ( 2880 rpm ) , horizontal, centrifugal, openwell submersible pumps set pre filled with coolent water and fitted with mechanical seal t / c vs t / c, thrust bearing shall be ofcarbon + s.s.the stator body of single phase pumpshall be of ss and rest of all shall be of cast iron. all casting parts should be cathod electro deposition ( ced ) coated and other construction material should be confirming to is : 14220: 2018 . the overall performance of pump shall confirm to bee energy efficiency level of 3 star. valid bee certificate from oem must be submitted for the same. motor should be ie2 class as per iec 60034 2 1: 2007, iec 60034 30: 2008, & is12615:2011, including making connection etc as required complete in all respect. oem shall have submitnabl / cpri / erda accrediatedlab type test certificate before execution. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 150 1.0 hp, 1 ø, ( 7 12 ) mtr, ( 405 240 ) lpm 151 sitc of monoblock motor pump set isi marked ( is:9079 2002 ) with tefc motor, motor should be ie2 class as per iec 60034 2 1: 2007, iec 60034 30: 2008, & is12615:2011. with stainless steel impellor, stainless steel shaft, mechanical seal, single / three phase ( 240 440 v ) permanent split capacitor type ( psc ) , fitted with thermal overload protection, including cost of hardware etc on existing platform complete. pump shall have following hp rating, phase, head, minimum discharge respectively complete in all respect. oem shall have submitnabl / cpri / erda accrediatedlab type test certificate before execution. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 152 1.0 hp, 1 ø, ( 10 120 ) mtr, ( 30 12 ) lpm 153 supply , installation, testing and comissioning ofinverter type air cooled hi wall split type air conditioners with latest star rating system as per bee amended upto date complete with indoor unit ( idu ) , out door unit ( odu ) , surface / concealed copper refrigerant piping with insulation ( closed cell elastomeric nitrile rubber tubular pipe section ) upto 3 mtr ( idu to odu ) , copper power cable upto 3.5 mtr ( idu to odu ) , r 32 / r 410 green refrigerant, wireless remote control, suitable for working between 230v + / 10% with low & high voltage cutoff and50 hz , single phaseacsupply capable of performing cooling, dehumidification, air circulation of following capacity with scroll / rotary compressor. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 154 1.5 tr iseer not less then 3.8 155 providing & fixing of is : 4985 2000 class 4 ( 10 kgf / sqcm ) upvc drain water piping withfittings ( is:7834 & 10kgf / sqcm ) like elbow, socket, tee, solvent cement jointing, support with ms hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following nominal sizes. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 156 25 mm 157 supply, fixing and testing of following capacity iso certified company made wall mounted stabilizer having output voltage variation from 200 v to 250 v ( + / 5% ) with input voltage variation from 170 v to 260 v, time delay facility from 2 to 4 minute and high cutoff at 270 v with providing of 16 amp / 20 amp industrialplug top making connection etc complete in all respect.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 158 4 kva 159 making hole in stone masonary / rcc wall / rcc slab with core cutter for accomodating refrigerant pipe / drain pipe / ms pipe / cables etc of following dia 160 150 mm dia per running inch length 161 supply & fixing ms powder coated stand suitable for 1.0 / 1.5 / 2.0 tr outdoor type of split ac.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 162 supply & fixing of dry powder agent ( as per is 4308:2019 ) , abc typefire extinguisher ( stored pressure type ) conforming to is:15683:2018 , powder coated internal & external surface deep drawn cylinder body of mild steel cr2 grade conforming to is: 513, squeeze grip forged brass release valve with inbuilt safety release device, diaphragm type, 0 to 28 bar range pressure gauge, 450 mm long epdm discharge tube, qr code for product traceability including fixing on wall with suitable anchor fasteners as required of following capacity. test certificates of all the parameters along with hydro test & burst test ( for cylinder body ) certificatefrom oem / external nabl accrediated lab is to be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr ....

Rajasthan State Road Development And Construction Corporation Limited - Rajasthan

36350189 tender for electrification work of iti building at arain district ajmer wiring of light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked mms ( is:9537 p iii ) virgin material pvc conduit & itsisi marked ( is:3419 1988 ) accessories, round tiles, 1.2 mm thickhot dipped galvanized modular box with earth terminal, 10a modular switch, modular face plate with grid plate, 3 pin ceiling rose / holder / 3 way connector, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 3 short point ( up to 3 mtr. ) 4 medium point ( up to 6 mtr. ) 5 long point ( up to 10 mtr. ) 6 wiring of twin control light point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) in recessed isi markedmms ( is:9537 p iii ) pvc conduit & its isi marked ( is:3419 1988 ) accessories, round tiles, 2 nos hot dipped galvanized m.s modularbox of 1.2 mm thickwith earth terminal, 2 nos10 a two way modular switch, 3 pin ceiling rose / holder / 3 way connector , modular face plate with grid plate, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 7 long point ( up to 10 mtr. ) 8 wiring of 3 / 5 pin 6 amp. light plug point with 1.5 sq. mm nominal sizefr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked mms ( is:9537 p iii ) pvc conduit & its isi marked ( is:3419 1988 ) accessories, hot dipped galvanizedmodular box of 1.2 mm thick with earth terminal, 10 a modularswitch, 3 / 5 pin 6 a modular socket, modular face plate with grid plate, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 9 on board 10 short point ( up to 3 mtr. ) 11 medium point ( up to 6 mtr. ) 12 long point ( up to 10 mtr. ) 13 s&f following sizes ( dia. ) of isi marked virgin material mms ( is:9537 p iii ) pvc conduit along withisi marked ( is:3419 1988 ) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. for additional technical parameters of product / work refer annexure a attached with this bsr 14 20 mm 15 25 mm 16 32 mm 17 40 mm 18 50 mm 19 s&f following sizesof isi marked ( is:14927 p ii ) virgin materialupvc trunking along with accessorieslike coupler, inner, outer, elbow, square box, tee, end cap etc. on surfacewithscrews, expansionfastenersas required. for additional technical parameters of product / work refer annexure a attached with this bsr 20 100 mm x 50 mm 21 150 mm x 50 mm 22 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from99.90 % purity copper, class 5 stranding in acc. to is:8130 / iec 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation pvc type a / c / d , flame retardant as per is 10810 53, better amperage rating as per is:3961 part 5, in existingsurface or recessed pvc / ms conduit / casing capping making connections with copper lugs of suitable size, ferrules, testing etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of product / work refer annexure a attached with this bsr 23 1 x 1.5 sq.mm 24 2 x 1.5 sq.mm 25 3x 1.5 sq.mm 26 1x 2.5 sq.mm 27 2 x 2.5 sq. mm. + 1x1.5sqmm 28 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 29 2 x 6.0 sq. mm. + 1 x 4.0 sq. mm. 30 2 x 6.0 sq.mm 31 2 x 4.0 sq.mm 32 4 x 10.0 sq.mm 33 4 x 16.0 sq.mm 34 supplying and drawing pe insulated & pvc sheathed unarmoured telephone cable with 0.5 mm dia. solid annealed electrolytic grade bare copper conductor as per is: 8130 / 84 &confirming to tec specification gr / wir / 06 03 march 2002in existingsurface or recessed conduit / casing capping. including ferruling on each pair for identification etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 35 2 pair 36 supply and laying of pe insulated jelly filledarmouredtelephone cable. with 0.6 mm thick solid annealed bare copper conductor and confirming to tec specificationsconfirming. to dot gr / cug 01 / aug.2003 in existing pipe / open trench / cable tray / on surface including making necessary connection, testing etc. as required of size. for additional technical parameters of product / work refer annexure a attached with this bsr 37 10 pair 38 50 pair 39 supplying and drawing coaxial cable 75 ohm impedance with foam pe insulated solid bare copper inner conductor, and ist outer conductor of bonded alum. tape and second outer conductor ofalum. alloy braidin existingsurface or recessed conduit / casing capping including making connections as required. for additional technical parameters of product / work refer annexure a attached with this bsr 40 rg 6 41 p / laying isi marked p.v.c. insulated submersible cable confirming to ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from99.90 % purity copper, stranding in acc. to is:8130 / iec 60228 forlower watt loss , oxygen freefor less chances of oxidization, insulation pvc type a / c / d , flame retardant as per is 10810 53, better amperage rating as per is:3961 part 5, existing pipe / open trench / cable tray / on surface including making connection etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 42 2.5 sq.mm 3 core flat / round 43 4.0 sq.mm 3 core flat / round 44 6.0 sq.mm 3 core flat / round 45 p & f paper phenolic resin bondedlaminates confirming to is : 2036 1995 for boxes / frames including making holes for switches etc, with brass screws, washers / zinc platednut and bolts as required. for additional technical parameters of product / work refer annexure a attached with this bsr 46 3.0 mm thick 47 4.8 mm thick 48 6.4 mm thick 49 p & f 1.2mm thickm.s. recessed fan box, hexagonal / round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mmlength extended on each side . all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr 50 p & f krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted, including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 51 10 pairs 52 50 pairs 53 supplying and fixing of power plug point with modular accessories as per pwd specification for electrical works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal / connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofisi marked modular 16 amp. switch ( is :3854 ) and 6 / 16 amp. socket outlet ( is:1293 ) making connection , testing , etc. as required. for specification ofwiring accessories refer chaptere 07related item & for additional technical parameters of product / work refer annexure a attached with this bsr 54 p&f metal clad / plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain / bakelite base in recessed / surface mounting heavy duty enclosure made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3. powder painted ( without mcb ) including making connections, testing etc.as required.for additional technical parameters of product / work refer annexure a attached with this bsr 55 20 amp, 3 pin + scrapping earth, 4 module 56 32 amp, 5 pin + scrapping earth, 8 module 57 making of hole in wall ( brick / stone ) of required and placing np 2 rcc pipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 58 up to 457 mm size 59 providing & fixing ofextra down rod of 15 mm dia . erw ( electrical resistance welded ) of 1.6mm nominal thick medium duty steelpipe including cutting, threading, drilling, fixing quarter pin etc as reqd.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 60 providing & fixing of single / multi tone electronic call bell as per pwd specification for electrical works, including making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 61 providing & fixing of modular type switch / bell push duly isi marked ( is :3854 ) with cm / l no. printed and made out of unbreakable and fire retardant vergin uv stabilized polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , minimum width ofswitch toggle ( push part ) should not less then 20mm, includingall as per pre approved by engineer in charge, making connections, testing etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 62 10 a one way switch 63 32 amp. 2 moduleswitch with ledindicator 64 providing & fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , includingall as per pre approved by engineer in charge, making connections, testing etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 65 6 a3 / 5 pin shuttered socket 66 25 amp. 2 module socket 67 providing & fixing of modular type 120 w step fan regulator duly isi marked ( is 11037:1984 ) with cm / l no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , includingall as per pre approved by engineer in charge, making connections, testing etc. as required.for additional technical parameters of product / work refer annexure a attached with this bsr 68 5 step fan regulator 2 module 360 dgree rotating 69 providing & fixing of following modular accessories as per pwd specification for electrical works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , includingall as per pre approved by engineer in charge, making connections, testing etc. as required.for additional technical parameters of product / work refer annexure a attached with this bsr 70 t.v. coaxial socket 71 rj 11 telephone jack double line 72 blanking plate 73 modular mcb 6 a to 32 adp 74 providing & fixing offollowing size mounting grid plates with cover plates made from fire retardent uv established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 75 1 / 2 module 76 8 module 77 providing & fixing ofwiring accessories oem fabricated following size gi box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess / surface suitable for modular accessories as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 78 1 2 module 79 6 / 8 module 80 providing & fixing of ip20 smd mid power led batten type integrated light fixture made from powder coated extruded aluminiumhousing with in built driver, system lumen efficacy = 110 lm / watt output, internal surge protection of 2.5 kv with short & open circuit protection , thd < 10% , p. f.=0.95, cri >80 , life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing on housing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 81 1170mm ( + / 10% ) led batten with min. lumen output 2200 lm 82 570mm ( + / 10% ) batten with min. lumen output 1000 lm 83 providing & fixing of ip 20 led recessed / surface mounted, round / sqauresmd mid power led downlight with power coated die cast aluminum housingwith uv stabilized non yellowish diffuser withbis complience 2.5 kv surge protected isolated driver, with short & open circuit protection, having efficiency > 85% . system lumen efficacy of = 110 lm / watt, thd < 10 % , pf.=0.95, cri >80, life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. 84 oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 85 surface mounting ( with extruded alumn. housing ) 86 minimum lumen output 1300 lm 87 minimum lumen output 1950 lm 88 providing & fixing of ip20, 2x2 led surface / recessedmounting mid power smd type led light fixture not less than 50mm housing depth made from crca sheet steel housing, high purity / transmisivity uv stabilized non yellowish diffuser for uniform light distribution. high efficiency with 4 kv internal / external surge protection bis certified isolated driver having efficiency > 85% , with short & open circuit protection ( integral with light fixture ) . system lumen efficacy of = 120 lm / watt , thd < 10 % , p.f.=0.95, cri >80 , life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. 89 oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 90 surface moutning 91 minimum lumen output 4200 lm 92 providing & fixing of ip65 ik08 rated integrated smd mid power led bulk head type light fixture made from pressure die cast al housing suitable with integral driver, system lumen efficacy =100 lm / watt output , thd < 10% , p.f.=0.95, cri >80 , life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. surge protection 4 kv. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 93 minimum lumen output 1000 lm 94 providing & fixing of 400 mm sweepbldc technology oscillating type wall mounting / pedestal typefans with three speed, on andoff position, double wall bearing withfront and back 120 or moreribs guard; three no.blades, noise level should be <= 75 db, including fixing with anchor bolts, making connection testing etc. as required. ( with remote ) all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 95 wall mounting type with service value 2.0 cmm / w, min. air delivery 71 cmm 96 providing & fixing ofbeestar rated copper wounded double ball bearing capacitor start, aluminium body & metallicblade ceilingfanconforming to all the performance requirements laid down in is 374:2019 including all amendments, as applicable ; & carry bis licensing ( i.e. isi marking ) with down rod up to 80 cm with secondary support safety cable ( steel rope ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 97 1200 mm sweep bee 1 star rated ( service value >=4.0 to < 4.5 ) 98 providing & fixing ofof double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor , making connections, testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 99 300 mm sweep 100 providing & fixing of heavy duty capacitor start, copper wounddouble ball bearing900 / 1400 rpm single phaseexhaustfan conforming to is:2312 isi marked in existing opening including making connections testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 101 300 mm sweep ( 900 / 1400 rpm ) 102 380 mm sweep ( 900 / 1400 rpm ) 103 providing & fixing ofof ventilating fans capacitor start, copper wounded, single phase with pvc impeller, abs body, automatic openable louver shutter in existing opening including making connection, testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 104 150 mm sweep 105 250 mm sweep 106 p & f of wall cowl with bird screen suitable for outside wall of exhaust fan openingof following size and made out from 24 swg gi sheet as per instructions of engineer in chargeincluding fixing with suitable fasteners etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 107 suitable for 300 mm sweep exhaust fan 108 suitable for 380 mm sweep exhaust fan 109 providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket / pole. fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with uv stabilized pc ( uv stablization report submitted for uv cover ) / toughened glass coverand secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm / wt and potted driver& has a unique bis r number withinput voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driverefficiency >85%, thd ( i ) <10%humidity 10% to 90% rh working temp 5c to 45c .driver current <750ma. the luminaireshall be bis certified and trade mark certified. life expectancyequal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min = 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs.manufactures word mark / name engraved / embossing on die cast housing to allow traceability / authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities forled fixtures. ( lm79 / lm80 ) certificate / report with liable warranty of product / accessories from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 110 led street light fixture with minimum lumen output 11225 lm 111 supply and erection ofgalvanized iron pole with galvanizing done in single dipping ( average coating thickness minimum 65 microns ) continuously tapered poles having octagonal / circular cross sections designed to withstand the maximum wind speed as per is 875, the pole shaft shall be made from sheet steel ( ht steel conforming to grade s355jo ) and confirming to bsen 10025 and shall be continuously tapered with single longitudinal welding. there shall not be any circumferential welding. the welding of pole shaft shall be done by submerged arc welding ( saw ) process. pole shafts shall be provided with the rigid flange plate of suitable thickness ( fe 410 conforming to is 226 / is 2062 ) with provision for fixing 4 no. foundation bolts, this base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.the octagonal poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the base plate with bakelite sheet having 6a sp mcb and 16 sqmm stud type connector ( 4 nos ) inside the pole at door opening for cable connection of following length and dimension as per table p 01 with base plate and foundation bolt on the existing cement concrete foundation.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 112 poles with octagonal cross section 113 7 mtr. 114 supply and fixing of pole oem fabricated hot dipped galvanised m.s. overhang ( 48.3 x 3.25 mm ) with cap ( 400 x 88.9 / 114.3 x 3.25 mm ) over the existing poles. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 115 single arm overhang 116 providing and laying rcc foundation for octagonal / conical street light poles, high mast poles as per drawing attach at tablep 4with following procedure& all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 117 a ) excavation of pit for foundation size upto required depth from ground level 118 b ) dressing of pit and dry stone pitching 200 mm thick including supply of stones and preparing surface complete. 119 c ) providing and laying in position cement concrete of m 10 grade of 75 mm thickness 120 d ) reinforcement for r.c.c. work with tmt bars including straightening, cutting, bending, placing in position and binding all complete. 121 e ) centring and shuttering including strutting , propping etc. and removal of form work for footing and pedestal 122 f ) providing & fixing of 2 no. required sizeplb hdpe pipe& foundation bolt with template as per oem recommendations. 123 g ) providing and layingreinforce cement concrete of m 25 grade in footing and pedestal including curing the foundation for 7 days. 124 h ) providing and fixing nosing angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. lugs on each face. 125 pole foundation for octagonal pole from 7 mtr. to 9 mtr. 126 providing & fixing of ik08ip65 protected top / bottom mounted led post top luminarie made of single piece constructionpowder coated die cast alluminium housing with uv stabalized clear / frosted polycarbonate diffuser andaluminium anodised with sand blast reflector. the system level luminous efficacy =100 lumen / w. smd leds is to be used, system cri>70, cct: 3000 / 4000 / 6500 k. the integral electronic driver must be potted & has a unique bis r number must be potted & has a unique bis r number constant current and internal / external surge protection device of min. 4kv ( l n ) and efficiency > 85%, pf>0.9, thd<10% and input voltage range of 140 270v ac at 50hz. system life of 50000 burning hours with 70% of initial lumens maintained . driver current <750ma.fixture must be in compliance with bis standards and trade mark certificate complete in all respect.oem must have its own in house nabl lab setup for all testing facilities forled fixtures. ( lm79 / lm80 ) certificate / report with liable warranty of product / accessories from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 127 minimum lumen output 4500 lm post top luminarie 128 providing & fixing of street light bracket made out from following size of b class , medium class g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with heavy duty pole clamp, saddles suitable fastners etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 129 40 mm dia. 130 supply , installation, testing and comissioning of is:1475 marked self contained drinking water cooler withhermeticallysealed compressor, non cfc refrigerent suitable for operation on 230v / 1ph / 50hz ac supply, full stainless steel ( ss304 ) body ( 0.8 mm thick ) and tank ( 0.5 mm thick ) , stainless steel water tray, minimum two nosbrass chrome plated faucets and suitable drainage system complete in all respect with requiredheight ms fabricated and painted angle iron frame ( cost of frame to be paid extra ) complete in all respect of the following capacity.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 131 cooling capacity 150 ltr. / hr. and storage capacity 150 ltrs 132 providing and laying non pressure np 3 classr.c.c. pipes including collars / spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) etc. as required. ( excavation of earth& back filling with compaction is to be paid extra ) . all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 133 200 mm dia. 134 labour charges for excavating trenches of required width for pipes dressing of sides, ramming of bottoms, depth up to 1.5 mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 mtr.: 135 all kind of soils 136 sitc of wall type following zone ( each zoneaccessing minimum 20 units ( detectors / devices ) ) conventional type microprocessor based with lcd display en / lpcb / ul listed / approved main control panel fabricated from 16 swg crca sheet steel sealed maintenance free ( smf ) batteries of min2x7ah of 12 v or as required.including the cost of all accessories, etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 137 4 zone 138 sitcof en / lpcb / ul listed / approved conventional type manual call point resettable complete with glass, hammer and chain etc.including the cost of all accessories etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 139 sitc of en / lpcb / ul listed / approved conventional type hooter cum strobe including the cost of all accessories, etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 140 supply & fixing of water + afff 6%mechanical foam typefire extinguisher ( stored pressure type ) conforming to is:15683:2018 , powder coated internal & external surface deep drawn cylinder body of mild steel cr2 grade conforming to is: 513, squeeze grip forged brass release valve with inbuilt safety release device, diaphragm type, 0 to 25 bar range pressure gauge, 450 mm long epdm discharge tube, qr code for product traceability including fixing on wall with suitable anchor fasteners as required of following capacity. test certificates of all the parameters along with hydro test & burst test ( for cylinder body ) certificatefrom oem / external nabl accrediated lab is to be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 141 capacity 6 ltrs. 142 supply & fixing of co2 type fire extinguisher conforming to is:15683:2018, charged with co2 gas ( purity 99.7% conforming to is 15222 ) , powder coated internal & external surface manganese steel isi marked as per is 7285 cylinder body , wheel type forged brass release valve isi marked as per is 3224 with inbuilt safety release device ( ( fusible plug and rupture disc type ) , 1.0 mtr. metal wire braided hose having minimum bursting pressure of 140 kgf / cm2, horn with metallic thread connection, qr code for product traceability, including fixing on wall with suitable anchor fasteners as required of following capacity. test certificates of all the parameters along with hydro test & burst test ( for cylinder body ) certificatefrom oem / external nabl accrediated lab is to be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 143 capacity 4.5 kg. 144 supply & fixing of dry powder agent ( as per is 4308:2019 ) , abc typefire extinguisher ( stored pressure type ) conforming to is:15683:2018 , powder coated internal & external surface deep drawn cylinder body of mild steel cr2 grade conforming to is: 513, squeeze grip forged brass release valve with inbuilt safety release device, diaphragm type, 0 to 28 bar range pressure gauge, 450 mm long epdm discharge tube, qr code for product traceability including fixing on wall with suitable anchor fasteners as required of following capacity. test certificates of all the parameters along with hydro test & burst test ( for cylinder body ) certificatefrom oem / external nabl accrediated lab is to be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 145 4 kg 146 supply , installation, testing and comissioning ofinverter type air cooled hi wall split type air conditioners with latest star rating system as per bee amended upto date complete with indoor unit ( idu ) , out door unit ( odu ) , surface / concealed copper refrigerant piping with insulation ( closed cell elastomeric nitrile rubber tubular pipe section ) upto 3 mtr ( idu to odu ) , copper power cable upto 3.5 mtr ( idu to odu ) , r 32 / r 410 green refrigerant, wireless remote control, suitable for working between 230v + / 10% with low & high voltage cutoff and50 hz , single phaseacsupply capable of performing cooling, dehumidification, air circulation of following capacity with scroll / rotary compressor. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 147 1.5 tr iseer not less then 4.6 148 2.0 tr iseer not less then 4.6 149 providing & fixing of is : 4985 2000 class 4 ( 10 kgf / sqcm ) upvc drain water piping withfittings ( is:7834 & 10kgf / sqcm ) like elbow, socket, tee, solvent cement jointing, support with ms hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following nominal sizes. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 150 25 mm 151 supply, fixing and testing of following capacity iso certified company made wall mounted stabilizer having output voltage variation from 200 v to 250 v ( + / 5% ) with input voltage variation from 170 v to 260 v, time delay facility from 2 to 4 minute and high cutoff at 270 v with providing of 16 amp / 20 amp industrialplug top making connection etc complete in all respect.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 152 4 kva 153 5 kva 154 making hole in stone masonary / rcc wall / rcc slab with core cutter for accomodating refrigerant pipe / drain pipe / ms pipe / cables etc of following dia 155 50 mm dia per running inch length 156 supply & fixing ms powder coated stand suitable for 1.0 / 1.5 / 2.0 tr outdoor type of split ac.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 157 sitc of interconnecting refrigerantcopper pipe forsplit / ductable / casseette ac of dhe grade c12200 astm b68, b75, chemical composition of copper % 99.0 min and phosphorus % 0.015 to 0.040 . for annealed copper tube : tensile strength = 210 mpa wih elongation % = 40 min . ink markbrand printing on hard tubes should be present. piping between each set of indoor & outdoor units of different sizesas per oem requirement & specifications including class o nitrile rubber sleeves, chase cutting, supports, making good the same with sand cement plaster etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 158 supplying and drawing flexible / stranded bare copper conductor, pvc / xlpe insulated, overall aluminium mylar tape shielded atc drain wire and outer pvc sheathed industrial instrumentation ( shielded ) cables voltage grade 300 / 500 v as per bs / en 50288 7 in existingsurface or recessed pvc / ms conduit / casing capping / cable tray / open duct making connections, testing etc. as required. oem must have its own in house nabl lab setup for all testing facilities for cables. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 159 un armoured 160 4 core x 2.5 sq.mm 161 providing & fixing of 240 / 415 v ac mcb with positive isolation of 10 ka breaking capacity ( b / c / d tripping characteristic as per type of load andsite requirement ) 4 kv impulse withstand voltage, isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted inexisting distribution board / sheets, minimum electrical operation 20, 000 upto 20 a rating and 10, 000 upto 63 a, 5000 for 80 a & above ratingincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 162 single pole mcb ( with b / c curve tripping characteristics ) 163 0.5 a to 5 a rating 164 6 a to 32 a rating 165 double pole mcb ( with b / c curve tripping characteristics ) 166 50 / 63 a rating 167 triple pole mcb ( with d curve tripping characteristics ) 168 6 a to 32 a rating 169 50 / 63 a rating 170 four pole mcb ( with b / c curve tripping characteristics ) 171 50 / 63 a rating 172 40 a rating 173 providing & fixing of 240 / 415 v residual current circuit breaker ( rccb ) conforming to ( is:12640 1 ) / iec 61008 1 , rated 4 kv impulse withstand voltage truly current operated and shall operate on cbct mechanisum, provision for pad lock, min. operation 10, 000 upto 63 a rating and5000 for 100 aratingand minimum phase termination capacity of 35 sq.mm. rigid wire, ip 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 174 two pole 100 / 300ma sensitivity 175 40 a rating 176 63 a rating 177 providing & fixing of recessed / surface mounting heavy duty horizontal type double door ( metal / glazed ) distribution board with metal end box made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3, powder painted complete with reversible door ( for double door db only ) 100 amp. insulated copper bus bar / shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar, masking sheet, making internal db terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 178 glazed door ( single phase ) ik 09 and ip 43 with metal end box 179 12 way ( 12+2 ) 180 metal door ( three phase ) per phase isolation, horizontal ik 09 and ip 43 with metal end box 181 4way ( incomer 8, sub incomer2+2+2 ) 182 6way ( incomer 8, sub incomer2+2+2 ) 183 8way ( incomer 8, sub incomer2+2+2 ) 184 12 way ( incomer 8, sub incomer2+2+2 ) 185 providing & fixing of recessed / surface mounting heavy duty vertical tpn distribution board with metal end box with provision of incomer suitable for 3 / 4 pole mccb and sp / tp mcb as outgoing , made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3. powder painted with reversible door ( for double door db only ) complete with insulated 160 ( upto 160 a incomer ) / 250 amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar, masking sheet, making internal db terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr 186 double door ip 43 & ik 09 with provision of incomer mccb 100 / 125 a rating with metal end box 187 4 way 188 6 way 189 8 way 190 12 way 191 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed arrmouredaluminiumcable confirming to is:1554 p i / is :7098 p i of 1.1 kv withh4 grade electrolyticaluminium conductor confirming to is 8130 of purity >99.6 %, round / flat strip armouring of cables, inner / outer sheath confirming to is:5831in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench / cable tray ( with cable tie ) includingtesting etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810.for additional technical parameters of product / work refer annexure a attached with this bsr 192 6.0 sq. mm 193 4 core 194 10.0 sq. mm 195 4 core 196 16.0 sq. mm 197 4 core 198 35.0 sq. mm 199 3.5 core 200 70.0 sq. mm 201 3.5 core 202 95.0 sq. mm 203 3.5 core 204 185.0 sq. mm 205 3.5 core 206 add extra for laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv gradedirect in ground including excavation of trench of size 75 cm ( depth ) x 35 cm ( width ) , with procedure as per followingpoints: ( a ) make a river sand bed of height 125 mm along the trench, ( b ) lay the cable in the middle of the trench, ( c ) provide river sand bed of height 125 mm on top of the cable, ( d ) lay the protective common burnt clay f.p.s. bricks of class designation 75 / sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( approx. 9 no. bricks per mtr. ) , ( e ) backfill the excavated soil leaving 300 mm from the ground level, ( f ) lay the cable warning tape and again back fill the remaining portion of the trench upto the ground level and compacting the earth 207 add extra for laying of one number additional pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv gradedirect in ground in the same trench in one tier horizontal formation including excavation of trench of size additional 20 cm in width, with procedure as per following points : ( a ) make a river sand bed of height 125 mm along the trench, ( b ) lay another cable in middle of trench in such manner that spacing between another cable is 20 cm., ( c ) provide river sand bed of height 125 mm on top of the cable. ( d ) lay the protective common burnt clay f.p.s. bricks of class designation 75 / sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( approx. 9 no. bricks per mtr. ) , ( e ) backfill the excavated soil leaving 300 mm from the ground level, ( f ) lay the cable warning tape and again back fill the remaining portion of the trench upto the ground level and compacting the earth. 208 supplying and making one end termination with nickel plated heavy duty brass single compression gland ( as per is 12943 1990 ) ) sibg type consisting of check nut, gland body, metal washer ( 3 nos. ) , outer seal rubber ring, compression nut, heavy duty aluminium lugs ( as per is 8309 1993 ) duly crimped with crimping tool, pvc tape as peris 8337 1976offollowing size ofpvc insulated & pvc sheathed / xlpe aluminium conductor cable of 1100 volt grade as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 209 3.5 x 185.0 sq.mm 210 3.5 x 95.0 sq.mm 211 3.5 x 70.0 sq.mm 212 3.5 x 35.0 sq.mm 213 4 x 16.0 sq.mm 214 4 x 10.0 sq.mm 215 4 x 6.0 sq.mm 216 supply, fabricating & installing following sizes of perforated hot dipped galvanized iron cable tray ( galvanized thickness not less then 50 microns ) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees, cross members and other accessories as required and duly suspended from the ceiling with gi suspenders including gi bolts & nuts , fastners, supports etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 217 150mm x 50mm x 1.6mm 218 p / l of double wall corrugated hdpe pipe confirming to is : 16205 p 24, stiffness class750 n, externally corrugated and having smooth surface insidewith hdpe coupler, elbow, teeat required depth below the ground for laying cable of followingnominal outer dia.mfr test reportfrom nabl accrediated is to be submitted. ( excavation of earth& back filling with compaction is to be paid extra ) all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 219 50 mm 220 110 mm 221 plate earthing as per is:3043 withcopper earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying3 mtr. below the ground level with 20mm dia. g.i. b class watering pipe , including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke / charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 222 supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % copperthickness ( 250 microns ) andconfirming toul 467, is / iec 62561 2of following size and length and as per point mentioned ( a ) , ( b ) , [ c ) , ( d ) , ( e ) below : 223 ( a ) bore a hole of dia. 100 mm of required length, place the rod in the centre of hole 224 ( b ) filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, cpri / erdatested with rms capacity of minimum 30 ka for withstanding 1 second .to ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. the compound shall be tested form nabl acredeated labfor lowresistivity ( less than 0.12 ohm meter ) & high conductivity in nature with carbon as a major contentas per referance of is 3043 1987, ieee 80 2013 ( clause 14.5d ) , ieee 837 & ier 1956 with latest amendemnts 225 © connect the rod with copper strip / conductor / wire with suitable clamp made from tinned copper and ss 304 bolt 226 ( d ) place heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height250 to 300 mm. 227 ( d ) testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 228 ( e ) test certificatesfor confirming above standards from oem is mandatory. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 229 25 mm thick and 3 mtr. long 230 supply & laying following size earth stripin horizontal or vertical run in surface by means of earth strip dmc insulatorincluding riveting / soldering / welding, jointing shall be done by overlapping and with 2 set of brass ( for cu strip ) / gi ( for gi strip ) nut bolt & spring washer spaced at 50cm making connection etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 231 25mm x 3mm g.i. ( hot dipped ) strip 232 50mm x 6mm g.i. ( hot dipped ) strip 233 40mm x 6mm copper strip 234 supply & laying following size b class , g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor / strip / cable in ground / surface / recess as required.all as per pre approved by engineer in charge. ( earth excavation will be paid extra ) all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annex ure a attached with this bsr . 235 50 mm dia. 236 65 mm dia. 237 80 mm dia. 238 100 mm dia. 239 150 mm dia. 240 supply & laying following size earth wire in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection with gi / cu purity purity >95%thimble etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 241 8 swg g.i. ( hot dipped ) wire 242 supply, drawing and testing of 4 pair, 23 awg solid bare copper wire insulated with pvc, utp ( unshielded twisted pair ) , category 6, class e, 100 ohm impedance, indoor cable as per latest ammendments of ansi / tia / eia 568 , the copper conductors should be balanced twisted in pairs, seperated by a cross member fluted pair divider & protected bypvc jacket. certified performance in a 4 connector configuration upto 100 mtrs channel requirements & transmission frequencies up to 250 mhz. in existing ms / pvc conduits / casing capping including making connections to information outlets and patch panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 243 supply and installation of unsheilded / 360 degree sheilded information outlets made of high impact plastic body with abs, fr grade halogen free material with provision for protection against dust in jack, suitable for cat 6 / 6a application complying to latest ammendments, according. to cat. 6 / 6a channel, it should support channel as well as components requirements of cat.6 / 6a standards at frequencies of up to 250 to 500 mhz. cat 6 / 6a unshielded / shielded jack should be suitable to terminate 4 pair, 23 / 24 awg solid / stranded wire diameters, using 100 ohm unshielded / shielded balance twisted pair cable, the jack should have tooless / impact termination on reliable copper tin plated insulation displacement contact, with easy lock mechanism, it supports iec 60603 7 4 and complied with ansi / tia / eia 568 c.2 standard. jack should be rj11, rj12 & rj45 compatible. should support ethernet 1.2 gb / s atm, digital video and broadband / baseband analog video, voice over internet protocal ( voip ) specifications in existing modular / ms boxes along with necessory connections as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 244 cat 6, un sheilded information outlet 245 supply & fixing of square faceplate for flush / surface mount information outlets single / dual or quad aperture , material should bepc+abs body, suitable for rj45 unshielded / shielded connection modules. should match with i. o. oem. dimensions should be 86mm x 86mm as required complete in all respect.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 246 single aperture 247 supply, installation, testing and comissioning of rack mounted 19 1u, cat6 24 port loaded, 1.5 1.6 mm crs chasis, powder coated, sheet steel, made of plastic ( abs ) , modular patch panelswith rear cable management system and mounting hardware to mount the patch panel. should have port identification numbers printed / engraved on front of the panel. etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 248 modular patch panel loaded with cat 6 i / o 249 supply , installation and testing of 4 pair, 100 ohm impedance, cat 6 / 6a / class e / ea patch cords should be constructed of minimum 23 / 24 awg, stranded bare copper cable with frpvc / lszh jacket, with an enhanced performance by factory moulded rj45 connectors with strain relief boots as per ansi / tia / eia 568 c.2 suitable for cat 6 / 6a application complying to latest ammendments category 6 / 6a standards, according. to tia568c.2, iso / iec 11801, en 50173, iec 60603 7 51, en 60603 7, ieee 802.3an minimum requirement for 1g base t to 10g base t performance. patch cords shall be straight thru cable compatible with both t568 a and t568 b wiring schemes, should support ieee 802.3af / ieee 802.3at for poe applications, minimum 750 to 1000 mating cycles in plug contacts for long durability, should support ethernet 10gbase t, 1.2 gb / s atm, token ring 4 / 16, digital video and broadband / baseband analog video, voice over internet protocal ( voip ) .all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 250 cat 6, u / utp ( unscreened / un sheilded twisted pair ) patch cord 251 1 mtr 252 2 mtr 253 supply & installation of ip 20 & ik 08 , ul listedwall mounted double section communication enclosure ( rack ) made from powder coated ( 60 to 80 micron ) crca sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door, vertical mounting rail 1.6 mm with umarking , with all round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. accessories like: 1 no of 19 1u horizontal cable manager, 1 no of 90 cfm 230v ac fan with 1 mts long cable, mounting hardware , 1 no of 19 1u, mountable socket strips with 5 nos of 5a universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with suitable anchor fastneretc as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 254 15 u rack with width 600 mm & depth 400 mm + 100 mm 255 supply & installation of ip 20 & ik 08 , ul listed communication enclosure ( rack ) made from powder coated ( 60 to 80 micron ) crca sheet, vertical mounting rail 1.6 mm with umarking, front sturdy sheet steel frame folded from one piece and welded with 5mm toughened glass door, with all round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, set of 75 mm height 4 castors, 2 of which have brakes, accessories like: 5 nos of 19 1u horizontal cable manager, 2 nos of vertical cable managers, 1 no. keyboard tray, 4 nos of 90 cfm 230v ac fan with 1 mts long cable, mounting hardware , 2 no of 19 1u, mountable socket strips with 6 nos of 5a universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 256 27 u rack with width 600 mm &depth 800 mm 257 supply , installation, testing and comissioning ofmanaged layer 2 intelligent 10 / 100 ethernet switch providing 24 x 10 / 100 / 1000 mbps giga ethernet ports / with min 2 sfp giga ports ( provision for fiber giga connectivity ) with related lan base software including making connections etc as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 258 providing & laying xlpe insulated three core armouredaluminiumcable for working voltage 11 k.v. ( e ) confirming is :7098 p 2withh4 grade electrolyticaluminium conductor confirming to is: 8130 class 2 of purity >99.6 %, insulation screening: extruded semiconducting compound followed by helically wrapped copper tape, round / flat strip armouring of cables , inner / outer sheath pvc type st 2 confirming to is:5831in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench / cable tray includingtesting etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810 all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 259 3 core 185.0 sq.mm 260 add extra for laying of one number xlpe power cable of 11 / 33 kv ( earthed ) voltage gradedirect in ground including excavation of trench of size 120 cm ( depth ) x 35 cm ( width ) , with procedure as per followingpoints: ( a ) make a river sand bed of height 125 mm along the trench, ( b ) lay the cable in the middle of the trench, ( c ) provide river sand bed of height 125 mm on top of the cable. ( d ) lay the protective common burnt clay f.p.s. bricks of class designation 75 / sand stone slabs of 50 mm thicknessand 225 mm wide just above the sand bed vertically across the cable ( approx. 9 no. bricks per mtr. ) , ( e ) backfill the excavated soil leaving 300 mm from the ground level, ( f ) lay the cable warning tape and again back fill the remaining portion of the trench upto the ground level and compacting the earth 261 providing & making heat shrinkable type indoor / outdoor / straight through terminations / joint kitsuitable for11 kv / 33 kv ( earthed ) cable with required components, prepration of cable ends. type test report should be as per is13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streightthrough joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. crosslinking shall be done out side factory with e beam / peroxide technology. extrusion process shall be in house oem within same vicinity. includingtesting etc. as required of following sizes. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 262 11 kv end termination kit indoor type 263 3 core 120 / 150 / 185 sq.mm 264 11 kv end termination kit outdoor type 265 3 core 120 / 150 / 185 sq.mm 266 providing & fixing of iso certified company made on load change over switch, front handle operated, four pole 415 v as per pwd specificationfor electrical works conforming to is / lec 60947 3 : 1999 including connections , testing etc. as required .in the following rating.appropriate type test certificate / oem test report shall be submitted .all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 267 open execution type 268 200 a 269 sitc of ip 42 and general construction confirming to is:8623 : 1993, wall / free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andother parameters requiredas per point ( a ) , ( b ) , ( c ) , ( d ) , ( e ) , ( f ) , ( g ) , ( h ) as below: 270 ( a ) thickness of crca sheet shallbe 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 271 ( b ) complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel.the panel having pe foam / neoprene rubber gasket of not less than 3mm thickness , required hardware , concealed hinged door with key type locking arrangement for equipment / switchgear earthed with 2.5 sq.mm braided copper wire. 272 [ c ) interconnection between bus bar and switchgears / cable shall be rigidly supported and made out by flexible copper wires ( up to 63 amp ) and by solid bus bar ( >63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only.all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgearis to be paid extra ) 273 ( d ) wiring between components within switchgear and incoming / outgoing cableshall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 274 ( e ) all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be ‘point to point’ ( no wire splitting or tee connections ) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 275 ( f ) floor mounted panel shall be mounted on base frame of ismcchannel size 100 x 50 x 5 mm ( to be paid extra ) 276 ( g ) tests: the insulation resistance ( with 1000 v megger ) and high voltage power frequency test ( by applying a voltage of 2.5kv for one minute ) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. the insulation resistance shall not be less than three megaohm. ct secondary current injection test shall also be carried out. 277 ( h ) only outer surface area on all sides shall be measured & panel to be fabricated only from cpri approved fabricator only ( cpri test certificates to be submitted ) all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 278 supplying and fixing of aluminium ( iec 60105 iso 209 1, 2 ) / copper ( iec 60028 ) bus bar by means of smc / dmc type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 279 electrolytic grade aluminium bus bar 6010 grade 280 providing & fixing of is: 13875 & iec :61326 confirming led digital type ( up to 500 ) v range volt meter / direct ammeter / ct oertated ammeter / frequency meter / kwh meter / multi function meter / power analyzer of class 1 accuracyas per is : 1248 of size 96mm x 96 mm including making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 281 threephase amp+hz+pf+kw+kva+kvar+t.energy+thd i, thd v & run hrs 282 providing & fixing of bis approvedcurrent transformeras per pwd specification for electrical works , isi marked as peris 2705 1992 / conforming to iec 60044 1, with secondary terminalof ct shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredcurrent transformer ring type tape wound / resin cast wound as per is 16227 with, accuracy cl, ct ratio and burden as specified. isf<=5, cu cross section of secondary wire 1.5sqmm ( minimum ) , including all necessary support in existing panel including connection etc. as required . all as per pre approved by engineer in charge.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 283 ring type tape wound ct 284 c t class 1, ratio 200 / 5 to 300 / 5, burden 10 va 285 c t class 1, ratio 400 / 5 to 1200 / 5, burden 15 va 286 providing & fixing ofcam operated rotary ( auto / manual ) switches on existing panel with 2 way and off position using high grade engineering materialto international standards with cam assemblyinsulation of glass filled polyamide with high tracking index. for reliable and stable electrical and mechanical endurance double butt contacts with silver bi metal on copper should provided . contact assembly is of operating temp range 25 degree c to 55 degree c, frequency upto 10 khz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles / hour and electrically 10, 000 operations at 100% rated duty for 100 cycles / hour including making connection etc.as required . all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 287 32 amp 288 providing & fixing of110 / 220 v, unibody led indicatinglamp iec 60947with integral circuit, ip 65 above panel &ip 20 terminal block, approx. body dia for panel not less then 20 mm, length min. 50mm, front led cover dia min.29 mm, contact material phospher bronze for led, pcb contacts shall be ofbrass ( tin plated ) , impulsedielectric tested for 2.5 kv, rated insulation resistance shall be 100 m ohm at 500vdcincluding connection etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 289 red / yellow / green colour 290 blue / white colour 291 providing & fixing of electricalinsulating rubber matts as per pwd specification for electrical works, isi marked confirming to is: 15652 / 2006with one sideanti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 292 11 kv, class b 2.5 mm thick with proof voltage 22 kv ac ( rms ) and break down voltage45 kv ac ( rms ) 293 providing & fixing of self healing ip20 mpp type shunt capacitor ( banks ) conforming to is:13340 41 / iec :831 1&2 or iec : 60831 1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( psd ) and shall have dissipation factor less than 0.0025 at 50 hz, operating loss less than 0.30 watt per kvar. min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, llife expectancy greater than 100000hrs ( temp class 25 d ) in 440 v / 480 v capacitor and for 525 v should life expectancy minimum 1, 65, 000 hrs ( temp class 25 d ) including making connections, testing etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 294 heavy dutythree phase 525v, 50 hzcylindrical typecapacitor ( bank ) 295 providing & fixing of ip54 microprocessor based 3 ct’s for all 3 phasesensing compensationpower factor correction relay size 139mm x 139 mm, operating voltage 415 / 440 v, iec / en 61000 6 ( 2&4 ) having 3 ct sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c / k setting according to targeted power factor setting, the relay shall havedigit display unit for display of real power factor, targeted power factor, lag / lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with rs 485, indication of switching on units, auto / manual status, and shall have over load protection, no volt release , having multi parameter like kw, kva, kvar, rms value, step switching time 2 sec to 1800 sec. lead & lag parameters, metering facility and3 no. class 0.5 cast resinct ( refer ct specs in this chapter ) for sensing the relay including making coonection with 1.5 sq.mm copper wire etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 296 12 to 14 stage 297 providing & fixing ofac operated heavy duty 230 / 440 volt power contactor as per pwd specification for electrical works, isi marked is / iec 60947 4 1 : 2000 having provision of mechanical interlocking, auxilary contacts, din rail mounting type including making connections, testing etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 298 3 pole power contactorswith following ac 3 rating 299 40 amp 300 providing & fixing of440 volt 3 pole capacitor ( ac 6 b ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors / reactors to limit the inrush current as per pwd specification for electrical works, is / iec 60947 4 1 : 2000, insulation voltage 1000v, impulse withstand voltage 8 kv, din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 301 up to 6 kvar 302 10 kvar 303 20.0 kvar 304 providing & fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and ac1 rating of 16 20 amperes including making connection, programming conforming to iec 60730 1 and 60730 2 7 etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 305 one day & week reserve ( digital type ) 306 sitc of3 / 4pole current limiting moulded case circuit breaker ( mccb ) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440 / 415 v, 50 hz; o / l & s / c settings , conforming to is / iec 60947 p 2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push ( test ) to trip, trip time less then 10 ms under s / c condition, breaking capacity ics = 100% icu. u imp =8 kv, rated insulation voltage690 v.provision for uvr , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.oem shall have submitnabl / cpri / erda accrediated lab type test certificate before execution all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 307 3 pole mccb with thermal magnetic release 308 160 amp , 25 ka, adjustable o / l & adjustable s / c setting, 309 4 pole mccb with thermal magnetic release 310 up to 100 amp , 25 ka, adjustable o / l & adjustable s / c setting, 311 125 amp , 25 ka, adjustable o / l & adjustable s / c setting, 312 160 amp , 25 ka, adjustable o / l & adjustable s / c setting, 313 200 amp , 25 ka, adjustable o / l & adjustable s / c setting, 314 250 amp , 35 ka, adjustable o / l & adjustable s / c setting, 315 400 amp , 35 ka, adjustable o / l & adjustable s / c setting, 316 s i t c of star ratedaluminium wound distribution transformerof following rating 11 / 0.433kv delta star connected, vector group dyn 11, onan cooled & as per bee star 1 & bis approved as per is 2026 1977 & lossesas defined as per 2014 ( fourth revision ) level 1 . including standardaccessories like conservator, silica gel breather, radiator, fins, ht cable box & lt cable boxes, temperature rise in winding / oil 35 40 degree c upto 200 kva & 40 45 degree c for above 200 kva, isi marked drain valve, dial type temperature gauge, first filling of transformer oil as per is :335 1953, epoxy based paint, including carrying of pre commission testing & charging of transformer complete in all respect . 317 the transformer shall be subjected to routine factory tests ( as per is:2026 and is:1180 ) including testing from ctlof discombefore charging of transformer & complete installaion must be certified from electrical inspectorate office as per indian electricity rule, ( ctl testing charges and electrical inspection charges shall be reimbursed by the department to the contractor ) . all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 318 250 kva with off ltc ( +5% to 10% @ 2.5% ) 319 sitc of 11kv 630 amps 21ka for 3 sec. sf6 insulated, outdoor duty ( ip54 ) , extensible / non extensible typering main unit ( rmu ) manually operated in combination ofvcb modules andload break switch consisting of copper busbar in sf6 insulated 304 ( non ferrite non magnetic grade ) stainless steel enclosure of thickness 2.5mm with manometer.the hv switchgear and control gear should be confirming to iec 62271 100, iec 62271 200 2003 & iec 60694 1996. the rmu should be internal arc tested for 21ka for 1second with iac afl classification for gas tank. vacum interrupter of vcb should be rmu manufacturer’s own make.each feeder of rmu should have voltage presence indicator. . and compring offollowings: 1 no. microprocessor based self powered numerical relay with over current / earth fault & short circuit protection with each vcb feeder. 3 nos. protection ct shall be of burden 2.5va, ratio 50 / 1a, class of accuracy class 5p10for o / c and e / f protection for each vcb. 1 no. manometer for each tank, 1 nos. fault passage indicator, right angle boots for all the feeder modulesall the type test certificates as per iec from third partynabl / cpri / erda accrediated lab to be submitted. ( cost of rcc foundation / steel structure to be paid extra ) all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr 320 non extensible 3 way rmu with 1 no. vcb & 2 no. load break switch 321 sitc of ht metering cubical panel as approved by discoms fabricated out of 18 swg crca sheet steel in two compartment & ms angle of size 60mmx 6mm having provision for following: ( i ) provision for fixing trivector / import export meter ( to be supplied by discoms ) ( ii ) provision for fixing of combined ct pt set with copper strip for connection ( to be supplied by discoms ) , ( iii ) test terminal block, ( iv ) 6mm thick bakelite sheet on all sides, ( v ) 3 / 6 corex 1.5 / 2.5 sq.mm copper cable for interconnections, etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 322 sitc of radiator cooled and turbo charged silent dg set ( as per latest cpcb emissionnorms ) havingspecifications as per a, b, c, d, e, f, g, h & i 323 a ) 1500 rpm diesel engine conforming to bs:649 / 5514 of suitable bhp ( up to 82.5 kva 6 cylinder or below required, 125 kva & above ratings 6 cylinder or aboverequired ) capable of taking 10% over loading for one hour after 12 hours of continuous operation., dry exhaust mainfold with hospital grade silencer and catalytic convertor ( isolated from main dg chamber ) , up to 3 m exhaust piping ( with lrb insulation & alum. cladding ) as required . 324 b ) ac brush less spdp alternator conform to bs 5000 ( part 99 ) or is / iec 60034 1. . alternator shall be self regulated with standard alternator protection ( over voltage , over speed & under voltage, under speed warning & shutdown ) .engine & alternator mounted on a common base frame & coupled through a flexible coupling or close coupled 325 c ) cpcb / arai approved standard canopy with weatherproof, powdercoated accoustic enclosure for dg set for sound attenuation fabricated from 1.6 mm crca sheet steel ( structure ) with sidewall fabricated from 1.6 mm crca sheet & filled with glasswool ( 96kg / m3 ) / foam. as per is8183 the doors of 28 / 40 / 50 / 85mm thick as perrating and fabricated from 1.6mm crca sheet packed with accoustic material, all doors / opening are sealed with neoprene / epdngaskets. the dg set has inbuilt / external in fuel tank to run 6 to 8 hrs as per oem standard, with protection and tripping of dg set against temperature of more than 50 degree centigrade. 326 d ) electronic / mechanical governor, manual & electric start , batteries with battry charger, engine instruments panel, avm pads all controls for operation of dg set are from outside the enclosure with dg control panel having microprocessor based genset monitoring like running hour, rpm, low lube oil tripping & control system, panel mounted mccb / acb of suitable rating, ammeter, voltmeter, pf meter, frequency meter, kwh meter, digital fuel display meter, ind.lamps etc. mounted inside enclosure , visible and accessible from outside. the enclosure should be suitable for following capacity dg sets and alternator. noise level shall be less than 75 db at a distance of 1 mtrs. duly certified by authorised agency etc. complete in all respect of following capacity : 327 e ) ( i ) accoustic glass wool wall thickness should not be less then 40mm and not less then 20mm pu foam upto rating 100 kva. ( ii ) .accoustic glass wool wall thickness should not be less then 65mm and not less then 50mm pu foam upto rating 250 kva. ( iii ) accoustic glass wool wall thickness should not be less then 100mm forrating above 250 kva. 328 f ) first filling of the fuel tank shall be done by contractor and the prevailing fuel cost at that time shall be reimbursed to the contactor by department. 329 g ) servicing contract of dg set from oems authorised service dealer as per oem guidelines during the dlp period shall be done by contractor including all consumables, actual charges shall be reimbursed to the contractor by end user department. 330 h ) manufacturer / oem must have its authorized service dealer in rajasthan. which can provide service within 6 hours of compalint registration. 331 i ) dg set will be offered for inspection and testing at manufacturers works in presence of departmental engineers. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 332 40 kva at 0.8 pf 415v 50hz 3 ? 333 sitc of plc based auto main failure ( amf ) panel fabricated from crca sheet steel 2 mmthick , powder coated finish , engine start & stopcommands, control relays , ammeter & voltmeterwith selector switches, control & 2 nos 4 pole power contactors with 2 no. of required size 4 pole mccb, timers, electronic hooter , visual & alarm indication for faults, ups, operator interface panel complete in all respect suitable for following capacity dg sets: appropriate test certificate / report of product / accessories from oem / panel manufecturer shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 334 20 to 40 kva 335 supply & fabrication steel structure with ms channel / angle / joist / ismb / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as requiredcomplete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 336 providing and fixing welded mesh / expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 x 50 x 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 ( 30x30x45cm ) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 337 earth work in excavation / by mechanical means ( hydraulic excavator ) / manual means over areas ( exceeding 30 cm in depth, 1.5m in width as well as 10 sum on plan ) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed: 338 random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 ( 1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size ) upto plinth level with cement mortar 1:6 ( 1 cement : 6 sand ) . 339 providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement all work up to plinth level 340 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) 341 plaster on new surface on wall in cement sand mortar 1:4 including racking of joints etc. complete fine finish : 342 20mm thick 343 finishing wall with water proofing cement paint of approved brand and manufacture and or required shadetogive an even shade including all scaffolding: 344 new work ( two or more coats applied @ 3.84 kg / 10 sqm ) . 345 sitc of single stage, water cooled, high speed ( 2880 rpm ) , horizontal, centrifugal, openwell submersible pumps set pre filled with coolent water and fitted with mechanical seal t / c vs t / c, thrust bearing shall be ofcarbon + s.s.the stator body of single phase pumpshall be of ss and rest of all shall be of cast iron. all casting parts should be cathod electro deposition ( ced ) coated and other construction material should be confirming to is : 14220: 2018 . the overall performance of pump shall confirm to bee energy efficiency level of 3 star. valid bee certificate from oem must be submitted for the same. motor should be ie2 class as per iec 60034 2 1: 2007, iec 60034 30: 2008, & is12615:2011, including making connection etc as required complete in all respect. oem shall have submitnabl / cpri / erda accrediatedlab type test certificate before execution. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 346 5.0 hp, 3 ø, ( 14 28 ) mtr, ( 995 500 ) lpm 347 sitc of contactoroem fabricated dol / star delta starter panel with switchgear selection as per type 2 cordinatiom chart andmade out from 1.6 mm thick powder coated crca sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, illuminated on / offpush buttons, ammeter, voltmeter, indicating lamps etc.suitable for following rating motors complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 348 for three phase submersible / mono block pump 349 3.0 hp to 5.0 hp ( dol starter ) 350 part b non bsr items based on market rate 351 sitc ofro water system with filtration stage = particulate filter membrane life enhancer filter sediment filter pre carbon filter ro membrane filter post carbon filter, input power rating 230 v ac , 50 hz, percentage of rejection tds 90% or better having following features ( a ) double purification by ro with ess or latest technology with tds indicator ( b ) .spin welded ro membrane housing to prevent tempering ( c ) . push fit components for leak proof performance ( d ) . fully automatic operation with auto start and auto off ( e ) . ss construction for corrosion free lifespan ( f ) . equally suitable for water from all bore wells, , overhead storage tanks, water tankers and even municipal taps ( g ) ro membrane flushing auto flush @ every start , every stop and every one hourof working for one minute. complete in all respect with following capacity. approved make:eureka forbes, kent, au smith, ion exchange, pentair. 352 purification capacity 50 lph, duty cycle 270 500 liters / day, 353 sitc of dome ip ir cctv cameras: network h.265 2mp ( full hd ) megapixel high frame rate mini dome camera with built in microphone:2mp ir dome camera with metal body and built in mic: 1 / 2.8 progressive scan cmos; resolution: 1920 × 1080@30fps or better; colour: 0.01 lux @ ( f1.2, agc on ) or better, h.265+ compression or better; 120 db true wdr or better; fixed 2.8 / 4mm lens; built in mic; 3d dnr; 40m ir range or better, triple streams; blc, 3d dnr, hlc; line crossing detection, intrusion detection; scene change detection; face detection; anti flicker, heartbeat, mirror, password protection, privacy mask, watermark, ip address filter; onvif ( profile s, profile g ) , isapi; built in micro sd / sdhc / sdxc slot, up to 128 gb or better; operating condition: 30 °c to +60 °c; ip67; 12dc & poe; certificate of compliance: ul, ce / fcc, bis, rohsapproved make: samsung / hikvision / panasonic / infinova / cp plus / dahua / honeywell 354 sitc of ip ir cctv bullet outdoor camera: network h.265 2mp ( full hd ) megapixel high frame rate ir bullet camera ( outdoor ) with metal body, 2mp full frame low light ir bullet camera: 1 / 2.5 progressive scan cmos; resolution: 1920 × 1080 or better; color: 0.002 lux @ ( f1.2, agc on ) or better; slow shutter; fixed 3.6 mm lens; triple streams; 3d dnr; 120db wdr; 50m ir range or better; line crossing detection, intrusion detection, object removal detection, unattended baggage detection, scene change detection; face detection; anti flicker, heartbeat, mirror, password protection, privacy mask, watermark, ip address filter; onvif ( profile s, profile g ) , isapi; roi; support micro sd / sdhc / sdxc card ( 128g ) , local storage and nas ( nfs, smb / cifs ) , anr; operating condition: 30 °c to +60 °c; ip67; 12dc & poe; metal body; built in junction box for cable management; certificate of compliance: ul, ce / fcc, bis / rohs approved make: samsung / hikvision / panasonic / infinova / cp plus / dahua / honeywell 355 sitc of raid 5 supported 32ch nvr with upto 48 tb hdd support 32ch ip inputs; dual os for redundancy; support anr technology;320mbps incoming bandwidth, supports up to 12mp full channel recording; support h.265 compression; 16ch syncronised playback @1080p; support raid 5; n+1 hot spare system; support 3rd party cameras; 4k output; minimum 8 sata hdd slots; each slot should suppport upto 6tb hdd; e sata interface; dual gigabit self adaptive ethernet interface; serial interace; usb interface; alarm in / out;dual power supply ( all cameras and storage nvr should be of same make for the smooth functioning of the system ) . certificate of compliance: ul, ce / fcc, bisapproved make: samsung / hikvision / panasonic / infinova / cp plus / dahua / honeywell 356 sitc of 3.5 6tb surveillance hard disk ( makes: seagate / wd / toshiba ) 357 sitc of workstation latest intel® i5 processor, with 17 led monitor screen intel chipset motherboard, 08 gb ram, 1 tb sata hdd at 7200 rpm, with 4gb gpu type higher end graphic card for h.265 compression technique with dual display ports / dvi / hdmi port, giga lan card, wireless keyboard, wireless optical mouse with original license windows software of approved makes: lenovo, hp, dell. 358 sitc of 55 flat smart screen hd profesional led with remote control and wall mount unit / floor stand complete with making connections etc of approved makes: lg, samsung, panasonic. 359 sitc of 5 kva 1 phase input, 1 phase output advance dsp controlled ups with igbt based rectifier, lcd display, double conversion / digital signal processing ups, with isolationtransformer, with 26ahx x 16 nos smf batteries for min 30 min back up, with ms rack for barreries and required cabling for incoming & outgoing connection of approved makes: numeric, eaton, emerson, apc. 360 supply, installation, testing & commissioning of managed layer 2 intelligent ethernet poe switches providing 08 x 10 / 100 / 1000 fast ethernet poe ports 67w or better and 2 dual purpose uplink ports ( provision for copper / fiber giga connectivity ) all switches & related fiber modules should be of same make & category for seamless integration with each other of approved makes: cisco catalyst series or equivalent in avaya, juniper ) 361 p & f of early streamer emission type lightning arrester on gi mast with air terminal configured as spheroid which is comprised ofseparate electrically isolated 4 panels surrounding an earthed central finial, the terminal shall be tested by cpri for impulse current of 45 ka ( 8 / 20 sec ) with 5 positive & 5 negative impulse, the arrester having following protection radius at level 1 approved makes :lpi ( australia ) , lpsfr ( france ) , sudafix ( uk ) , ef ( switzerland ) , abb 362 30 48 mtr. 363 s & laying of p.v.c. / xlpe insulated & p.v.c. sheathed down conductor of 70 sq.mm single core insulated flexible copper cable confirming to is:1554 p i / is :7098 p i of 1.1 kv withelectrolytic gradecopper made of copper rodsconfirming to is 613 1964, of purity >99.7 %, inner / outer sheath confirming to is:5831 with accessories as required. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810approved makes: polycab, rr, finolex....

Rajasthan State Road Development And Construction Corporation Limited - Rajasthan

36348916 tender for electrification work of iti building at kareda district bhilwara wiring of light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked mms ( is:9537 p iii ) virgin material pvc conduit & itsisi marked ( is:3419 1988 ) accessories, round tiles, 1.2 mm thickhot dipped galvanized modular box with earth terminal, 10a modular switch, modular face plate with grid plate, 3 pin ceiling rose / holder / 3 way connector, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 3 short point ( up to 3 mtr. ) 4 medium point ( up to 6 mtr. ) 5 long point ( up to 10 mtr. ) 6 wiring of twin control light point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) in recessed isi markedmms ( is:9537 p iii ) pvc conduit & its isi marked ( is:3419 1988 ) accessories, round tiles, 2 nos hot dipped galvanized m.s modularbox of 1.2 mm thickwith earth terminal, 2 nos10 a two way modular switch, 3 pin ceiling rose / holder / 3 way connector , modular face plate with grid plate, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 7 long point ( up to 10 mtr. ) 8 wiring of 3 / 5 pin 6 amp. light plug point with 1.5 sq. mm nominal sizefr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked mms ( is:9537 p iii ) pvc conduit & its isi marked ( is:3419 1988 ) accessories, hot dipped galvanizedmodular box of 1.2 mm thick with earth terminal, 10 a modularswitch, 3 / 5 pin 6 a modular socket, modular face plate with grid plate, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 9 on board 10 short point ( up to 3 mtr. ) 11 medium point ( up to 6 mtr. ) 12 long point ( up to 10 mtr. ) 13 s&f following sizes ( dia. ) of isi marked virgin material mms ( is:9537 p iii ) pvc conduit along withisi marked ( is:3419 1988 ) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. for additional technical parameters of product / work refer annexure a attached with this bsr 14 20 mm 15 25 mm 16 32 mm 17 40 mm 18 50 mm 19 s&f following sizesof isi marked ( is:14927 p ii ) virgin materialupvc trunking along with accessorieslike coupler, inner, outer, elbow, square box, tee, end cap etc. on surfacewithscrews, expansionfastenersas required. for additional technical parameters of product / work refer annexure a attached with this bsr 20 100 mm x 50 mm 21 150 mm x 50 mm 22 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from99.90 % purity copper, class 5 stranding in acc. to is:8130 / iec 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation pvc type a / c / d , flame retardant as per is 10810 53, better amperage rating as per is:3961 part 5, in existingsurface or recessed pvc / ms conduit / casing capping making connections with copper lugs of suitable size, ferrules, testing etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of product / work refer annexure a attached with this bsr 23 1 x 1.5 sq.mm 24 2 x 1.5 sq.mm 25 3x 1.5 sq.mm 26 1x 2.5 sq.mm 27 2 x 2.5 sq. mm. + 1x1.5sqmm 28 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 29 2 x 6.0 sq. mm. + 1 x 4.0 sq. mm. 30 2 x 6.0 sq.mm 31 2 x 4.0 sq.mm 32 4 x 10.0 sq.mm 33 4 x 16.0 sq.mm 34 supplying and drawing pe insulated & pvc sheathed unarmoured telephone cable with 0.5 mm dia. solid annealed electrolytic grade bare copper conductor as per is: 8130 / 84 &confirming to tec specification gr / wir / 06 03 march 2002in existingsurface or recessed conduit / casing capping. including ferruling on each pair for identification etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 35 2 pair 36 supply and laying of pe insulated jelly filledarmouredtelephone cable. with 0.6 mm thick solid annealed bare copper conductor and confirming to tec specificationsconfirming. to dot gr / cug 01 / aug.2003 in existing pipe / open trench / cable tray / on surface including making necessary connection, testing etc. as required of size. for additional technical parameters of product / work refer annexure a attached with this bsr 37 10 pair 38 50 pair 39 supplying and drawing coaxial cable 75 ohm impedance with foam pe insulated solid bare copper inner conductor, and ist outer conductor of bonded alum. tape and second outer conductor ofalum. alloy braidin existingsurface or recessed conduit / casing capping including making connections as required. for additional technical parameters of product / work refer annexure a attached with this bsr 40 rg 6 41 p / laying isi marked p.v.c. insulated submersible cable confirming to ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from99.90 % purity copper, stranding in acc. to is:8130 / iec 60228 forlower watt loss , oxygen freefor less chances of oxidization, insulation pvc type a / c / d , flame retardant as per is 10810 53, better amperage rating as per is:3961 part 5, existing pipe / open trench / cable tray / on surface including making connection etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 42 2.5 sq.mm 3 core flat / round 43 4.0 sq.mm 3 core flat / round 44 6.0 sq.mm 3 core flat / round 45 p & f paper phenolic resin bondedlaminates confirming to is : 2036 1995 for boxes / frames including making holes for switches etc, with brass screws, washers / zinc platednut and bolts as required. for additional technical parameters of product / work refer annexure a attached with this bsr 46 3.0 mm thick 47 4.8 mm thick 48 6.4 mm thick 49 p & f 1.2mm thickm.s. recessed fan box, hexagonal / round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mmlength extended on each side . all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr 50 p & f krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted, including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 51 10 pairs 52 50 pairs 53 supplying and fixing of power plug point with modular accessories as per pwd specification for electrical works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal / connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofisi marked modular 16 amp. switch ( is :3854 ) and 6 / 16 amp. socket outlet ( is:1293 ) making connection , testing , etc. as required. for specification ofwiring accessories refer chaptere 07related item & for additional technical parameters of product / work refer annexure a attached with this bsr 54 p&f metal clad / plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain / bakelite base in recessed / surface mounting heavy duty enclosure made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3. powder painted ( without mcb ) including making connections, testing etc.as required.for additional technical parameters of product / work refer annexure a attached with this bsr 55 20 amp, 3 pin + scrapping earth, 4 module 56 32 amp, 5 pin + scrapping earth, 8 module 57 making of hole in wall ( brick / stone ) of required and placing np 2 rcc pipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 58 up to 457 mm size 59 providing & fixing ofextra down rod of 15 mm dia . erw ( electrical resistance welded ) of 1.6mm nominal thick medium duty steelpipe including cutting, threading, drilling, fixing quarter pin etc as reqd.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 60 providing & fixing of single / multi tone electronic call bell as per pwd specification for electrical works, including making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 61 providing & fixing of modular type switch / bell push duly isi marked ( is :3854 ) with cm / l no. printed and made out of unbreakable and fire retardant vergin uv stabilized polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , minimum width ofswitch toggle ( push part ) should not less then 20mm, includingall as per pre approved by engineer in charge, making connections, testing etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 62 10 a one way switch 63 32 amp. 2 moduleswitch with ledindicator 64 providing & fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , includingall as per pre approved by engineer in charge, making connections, testing etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 65 6 a3 / 5 pin shuttered socket 66 25 amp. 2 module socket 67 providing & fixing of modular type 120 w step fan regulator duly isi marked ( is 11037:1984 ) with cm / l no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , includingall as per pre approved by engineer in charge, making connections, testing etc. as required.for additional technical parameters of product / work refer annexure a attached with this bsr 68 5 step fan regulator 2 module 360 dgree rotating 69 providing & fixing of following modular accessories as per pwd specification for electrical works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , includingall as per pre approved by engineer in charge, making connections, testing etc. as required.for additional technical parameters of product / work refer annexure a attached with this bsr 70 t.v. coaxial socket 71 rj 11 telephone jack double line 72 blanking plate 73 modular mcb 6 a to 32 adp 74 providing & fixing offollowing size mounting grid plates with cover plates made from fire retardent uv established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 75 1 / 2 module 76 8 module 77 providing & fixing ofwiring accessories oem fabricated following size gi box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess / surface suitable for modular accessories as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 78 1 2 module 79 6 / 8 module 80 providing & fixing of ip20 smd mid power led batten type integrated light fixture made from powder coated extruded aluminiumhousing with in built driver, system lumen efficacy = 110 lm / watt output, internal surge protection of 2.5 kv with short & open circuit protection , thd < 10% , p. f.=0.95, cri >80 , life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing on housing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 81 1170mm ( + / 10% ) led batten with min. lumen output 2200 lm 82 570mm ( + / 10% ) batten with min. lumen output 1000 lm 83 providing & fixing of ip 20 led recessed / surface mounted, round / sqauresmd mid power led downlight with power coated die cast aluminum housingwith uv stabilized non yellowish diffuser withbis complience 2.5 kv surge protected isolated driver, with short & open circuit protection, having efficiency > 85% . system lumen efficacy of = 110 lm / watt, thd < 10 % , pf.=0.95, cri >80, life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. 84 oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 85 surface mounting ( with extruded alumn. housing ) 86 minimum lumen output 1300 lm 87 minimum lumen output 1950 lm 88 providing & fixing of ip20, 2x2 led surface / recessedmounting mid power smd type led light fixture not less than 50mm housing depth made from crca sheet steel housing, high purity / transmisivity uv stabilized non yellowish diffuser for uniform light distribution. high efficiency with 4 kv internal / external surge protection bis certified isolated driver having efficiency > 85% , with short & open circuit protection ( integral with light fixture ) . system lumen efficacy of = 120 lm / watt , thd < 10 % , p.f.=0.95, cri >80 , life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. 89 oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 90 surface moutning 91 minimum lumen output 4200 lm 92 providing & fixing of ip65 ik08 rated integrated smd mid power led bulk head type light fixture made from pressure die cast al housing suitable with integral driver, system lumen efficacy =100 lm / watt output , thd < 10% , p.f.=0.95, cri >80 , life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. surge protection 4 kv. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 93 minimum lumen output 1000 lm 94 providing & fixing of 400 mm sweepbldc technology oscillating type wall mounting / pedestal typefans with three speed, on andoff position, double wall bearing withfront and back 120 or moreribs guard; three no.blades, noise level should be <= 75 db, including fixing with anchor bolts, making connection testing etc. as required. ( with remote ) all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 95 wall mounting type with service value 2.0 cmm / w, min. air delivery 71 cmm 96 providing & fixing ofbeestar rated copper wounded double ball bearing capacitor start, aluminium body & metallicblade ceilingfanconforming to all the performance requirements laid down in is 374:2019 including all amendments, as applicable ; & carry bis licensing ( i.e. isi marking ) with down rod up to 80 cm with secondary support safety cable ( steel rope ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 97 1200 mm sweep bee 1 star rated ( service value >=4.0 to < 4.5 ) 98 providing & fixing ofof double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor , making connections, testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 99 300 mm sweep 100 providing & fixing of heavy duty capacitor start, copper wounddouble ball bearing900 / 1400 rpm single phaseexhaustfan conforming to is:2312 isi marked in existing opening including making connections testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 101 300 mm sweep ( 900 / 1400 rpm ) 102 380 mm sweep ( 900 / 1400 rpm ) 103 providing & fixing ofof ventilating fans capacitor start, copper wounded, single phase with pvc impeller, abs body, automatic openable louver shutter in existing opening including making connection, testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 104 150 mm sweep 105 250 mm sweep 106 p & f of wall cowl with bird screen suitable for outside wall of exhaust fan openingof following size and made out from 24 swg gi sheet as per instructions of engineer in chargeincluding fixing with suitable fasteners etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 107 suitable for 300 mm sweep exhaust fan 108 suitable for 380 mm sweep exhaust fan 109 providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket / pole. fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with uv stabilized pc ( uv stablization report submitted for uv cover ) / toughened glass coverand secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm / wt and potted driver& has a unique bis r number withinput voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driverefficiency >85%, thd ( i ) <10%humidity 10% to 90% rh working temp 5c to 45c .driver current <750ma. the luminaireshall be bis certified and trade mark certified. life expectancyequal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min = 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs.manufactures word mark / name engraved / embossing on die cast housing to allow traceability / authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities forled fixtures. ( lm79 / lm80 ) certificate / report with liable warranty of product / accessories from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 110 led street light fixture with minimum lumen output 11225 lm 111 supply and erection ofgalvanized iron pole with galvanizing done in single dipping ( average coating thickness minimum 65 microns ) continuously tapered poles having octagonal / circular cross sections designed to withstand the maximum wind speed as per is 875, the pole shaft shall be made from sheet steel ( ht steel conforming to grade s355jo ) and confirming to bsen 10025 and shall be continuously tapered with single longitudinal welding. there shall not be any circumferential welding. the welding of pole shaft shall be done by submerged arc welding ( saw ) process. pole shafts shall be provided with the rigid flange plate of suitable thickness ( fe 410 conforming to is 226 / is 2062 ) with provision for fixing 4 no. foundation bolts, this base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.the octagonal poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the base plate with bakelite sheet having 6a sp mcb and 16 sqmm stud type connector ( 4 nos ) inside the pole at door opening for cable connection of following length and dimension as per table p 01 with base plate and foundation bolt on the existing cement concrete foundation.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 112 poles with octagonal cross section 113 7 mtr. 114 supply and fixing of pole oem fabricated hot dipped galvanised m.s. overhang ( 48.3 x 3.25 mm ) with cap ( 400 x 88.9 / 114.3 x 3.25 mm ) over the existing poles. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 115 single arm overhang 116 providing and laying rcc foundation for octagonal / conical street light poles, high mast poles as per drawing attach at tablep 4with following procedure& all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 117 a ) excavation of pit for foundation size upto required depth from ground level 118 b ) dressing of pit and dry stone pitching 200 mm thick including supply of stones and preparing surface complete. 119 c ) providing and laying in position cement concrete of m 10 grade of 75 mm thickness 120 d ) reinforcement for r.c.c. work with tmt bars including straightening, cutting, bending, placing in position and binding all complete. 121 e ) centring and shuttering including strutting , propping etc. and removal of form work for footing and pedestal 122 f ) providing & fixing of 2 no. required sizeplb hdpe pipe& foundation bolt with template as per oem recommendations. 123 g ) providing and layingreinforce cement concrete of m 25 grade in footing and pedestal including curing the foundation for 7 days. 124 h ) providing and fixing nosing angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. lugs on each face. 125 pole foundation for octagonal pole from 7 mtr. to 9 mtr. 126 providing & fixing of ik08ip65 protected top / bottom mounted led post top luminarie made of single piece constructionpowder coated die cast alluminium housing with uv stabalized clear / frosted polycarbonate diffuser andaluminium anodised with sand blast reflector. the system level luminous efficacy =100 lumen / w. smd leds is to be used, system cri>70, cct: 3000 / 4000 / 6500 k. the integral electronic driver must be potted & has a unique bis r number must be potted & has a unique bis r number constant current and internal / external surge protection device of min. 4kv ( l n ) and efficiency > 85%, pf>0.9, thd<10% and input voltage range of 140 270v ac at 50hz. system life of 50000 burning hours with 70% of initial lumens maintained . driver current <750ma.fixture must be in compliance with bis standards and trade mark certificate complete in all respect.oem must have its own in house nabl lab setup for all testing facilities forled fixtures. ( lm79 / lm80 ) certificate / report with liable warranty of product / accessories from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 127 minimum lumen output 4500 lm post top luminarie 128 providing & fixing of street light bracket made out from following size of b class , medium class g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with heavy duty pole clamp, saddles suitable fastners etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 129 40 mm dia. 130 supply , installation, testing and comissioning of is:1475 marked self contained drinking water cooler withhermeticallysealed compressor, non cfc refrigerent suitable for operation on 230v / 1ph / 50hz ac supply, full stainless steel ( ss304 ) body ( 0.8 mm thick ) and tank ( 0.5 mm thick ) , stainless steel water tray, minimum two nosbrass chrome plated faucets and suitable drainage system complete in all respect with requiredheight ms fabricated and painted angle iron frame ( cost of frame to be paid extra ) complete in all respect of the following capacity.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 131 cooling capacity 150 ltr. / hr. and storage capacity 150 ltrs 132 providing and laying non pressure np 3 classr.c.c. pipes including collars / spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) etc. as required. ( excavation of earth& back filling with compaction is to be paid extra ) . all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 133 200 mm dia. 134 labour charges for excavating trenches of required width for pipes dressing of sides, ramming of bottoms, depth up to 1.5 mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 mtr.: 135 all kind of soils 136 sitc of wall type following zone ( each zoneaccessing minimum 20 units ( detectors / devices ) ) conventional type microprocessor based with lcd display en / lpcb / ul listed / approved main control panel fabricated from 16 swg crca sheet steel sealed maintenance free ( smf ) batteries of min2x7ah of 12 v or as required.including the cost of all accessories, etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 137 4 zone 138 sitcof en / lpcb / ul listed / approved conventional type manual call point resettable complete with glass, hammer and chain etc.including the cost of all accessories etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 139 sitc of en / lpcb / ul listed / approved conventional type hooter cum strobe including the cost of all accessories, etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 140 supply & fixing of water + afff 6%mechanical foam typefire extinguisher ( stored pressure type ) conforming to is:15683:2018 , powder coated internal & external surface deep drawn cylinder body of mild steel cr2 grade conforming to is: 513, squeeze grip forged brass release valve with inbuilt safety release device, diaphragm type, 0 to 25 bar range pressure gauge, 450 mm long epdm discharge tube, qr code for product traceability including fixing on wall with suitable anchor fasteners as required of following capacity. test certificates of all the parameters along with hydro test & burst test ( for cylinder body ) certificatefrom oem / external nabl accrediated lab is to be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 141 capacity 6 ltrs. 142 supply & fixing of co2 type fire extinguisher conforming to is:15683:2018, charged with co2 gas ( purity 99.7% conforming to is 15222 ) , powder coated internal & external surface manganese steel isi marked as per is 7285 cylinder body , wheel type forged brass release valve isi marked as per is 3224 with inbuilt safety release device ( ( fusible plug and rupture disc type ) , 1.0 mtr. metal wire braided hose having minimum bursting pressure of 140 kgf / cm2, horn with metallic thread connection, qr code for product traceability, including fixing on wall with suitable anchor fasteners as required of following capacity. test certificates of all the parameters along with hydro test & burst test ( for cylinder body ) certificatefrom oem / external nabl accrediated lab is to be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 143 capacity 4.5 kg. 144 supply & fixing of dry powder agent ( as per is 4308:2019 ) , abc typefire extinguisher ( stored pressure type ) conforming to is:15683:2018 , powder coated internal & external surface deep drawn cylinder body of mild steel cr2 grade conforming to is: 513, squeeze grip forged brass release valve with inbuilt safety release device, diaphragm type, 0 to 28 bar range pressure gauge, 450 mm long epdm discharge tube, qr code for product traceability including fixing on wall with suitable anchor fasteners as required of following capacity. test certificates of all the parameters along with hydro test & burst test ( for cylinder body ) certificatefrom oem / external nabl accrediated lab is to be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 145 4 kg 146 supply , installation, testing and comissioning ofinverter type air cooled hi wall split type air conditioners with latest star rating system as per bee amended upto date complete with indoor unit ( idu ) , out door unit ( odu ) , surface / concealed copper refrigerant piping with insulation ( closed cell elastomeric nitrile rubber tubular pipe section ) upto 3 mtr ( idu to odu ) , copper power cable upto 3.5 mtr ( idu to odu ) , r 32 / r 410 green refrigerant, wireless remote control, suitable for working between 230v + / 10% with low & high voltage cutoff and50 hz , single phaseacsupply capable of performing cooling, dehumidification, air circulation of following capacity with scroll / rotary compressor. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 147 1.5 tr iseer not less then 4.6 148 2.0 tr iseer not less then 4.6 149 providing & fixing of is : 4985 2000 class 4 ( 10 kgf / sqcm ) upvc drain water piping withfittings ( is:7834 & 10kgf / sqcm ) like elbow, socket, tee, solvent cement jointing, support with ms hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following nominal sizes. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 150 25 mm 151 supply, fixing and testing of following capacity iso certified company made wall mounted stabilizer having output voltage variation from 200 v to 250 v ( + / 5% ) with input voltage variation from 170 v to 260 v, time delay facility from 2 to 4 minute and high cutoff at 270 v with providing of 16 amp / 20 amp industrialplug top making connection etc complete in all respect.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 152 4 kva 153 5 kva 154 making hole in stone masonary / rcc wall / rcc slab with core cutter for accomodating refrigerant pipe / drain pipe / ms pipe / cables etc of following dia 155 50 mm dia per running inch length 156 supply & fixing ms powder coated stand suitable for 1.0 / 1.5 / 2.0 tr outdoor type of split ac.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 157 sitc of interconnecting refrigerantcopper pipe forsplit / ductable / casseette ac of dhe grade c12200 astm b68, b75, chemical composition of copper % 99.0 min and phosphorus % 0.015 to 0.040 . for annealed copper tube : tensile strength = 210 mpa wih elongation % = 40 min . ink markbrand printing on hard tubes should be present. piping between each set of indoor & outdoor units of different sizesas per oem requirement & specifications including class o nitrile rubber sleeves, chase cutting, supports, making good the same with sand cement plaster etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 158 supplying and drawing flexible / stranded bare copper conductor, pvc / xlpe insulated, overall aluminium mylar tape shielded atc drain wire and outer pvc sheathed industrial instrumentation ( shielded ) cables voltage grade 300 / 500 v as per bs / en 50288 7 in existingsurface or recessed pvc / ms conduit / casing capping / cable tray / open duct making connections, testing etc. as required. oem must have its own in house nabl lab setup for all testing facilities for cables. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 159 un armoured 160 4 core x 2.5 sq.mm 161 providing & fixing of 240 / 415 v ac mcb with positive isolation of 10 ka breaking capacity ( b / c / d tripping characteristic as per type of load andsite requirement ) 4 kv impulse withstand voltage, isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted inexisting distribution board / sheets, minimum electrical operation 20, 000 upto 20 a rating and 10, 000 upto 63 a, 5000 for 80 a & above ratingincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 162 single pole mcb ( with b / c curve tripping characteristics ) 163 0.5 a to 5 a rating 164 6 a to 32 a rating 165 double pole mcb ( with b / c curve tripping characteristics ) 166 50 / 63 a rating 167 triple pole mcb ( with d curve tripping characteristics ) 168 6 a to 32 a rating 169 50 / 63 a rating 170 four pole mcb ( with b / c curve tripping characteristics ) 171 50 / 63 a rating 172 40 a rating 173 providing & fixing of 240 / 415 v residual current circuit breaker ( rccb ) conforming to ( is:12640 1 ) / iec 61008 1 , rated 4 kv impulse withstand voltage truly current operated and shall operate on cbct mechanisum, provision for pad lock, min. operation 10, 000 upto 63 a rating and5000 for 100 aratingand minimum phase termination capacity of 35 sq.mm. rigid wire, ip 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 174 two pole 100 / 300ma sensitivity 175 40 a rating 176 63 a rating 177 providing & fixing of recessed / surface mounting heavy duty horizontal type double door ( metal / glazed ) distribution board with metal end box made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3, powder painted complete with reversible door ( for double door db only ) 100 amp. insulated copper bus bar / shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar, masking sheet, making internal db terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 178 glazed door ( single phase ) ik 09 and ip 43 with metal end box 179 12 way ( 12+2 ) 180 metal door ( three phase ) per phase isolation, horizontal ik 09 and ip 43 with metal end box 181 4way ( incomer 8, sub incomer2+2+2 ) 182 6way ( incomer 8, sub incomer2+2+2 ) 183 8way ( incomer 8, sub incomer2+2+2 ) 184 12 way ( incomer 8, sub incomer2+2+2 ) 185 providing & fixing of recessed / surface mounting heavy duty vertical tpn distribution board with metal end box with provision of incomer suitable for 3 / 4 pole mccb and sp / tp mcb as outgoing , made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3. powder painted with reversible door ( for double door db only ) complete with insulated 160 ( upto 160 a incomer ) / 250 amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar, masking sheet, making internal db terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr 186 double door ip 43 & ik 09 with provision of incomer mccb 100 / 125 a rating with metal end box 187 4 way 188 6 way 189 8 way 190 12 way 191 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed arrmouredaluminiumcable confirming to is:1554 p i / is :7098 p i of 1.1 kv withh4 grade electrolyticaluminium conductor confirming to is 8130 of purity >99.6 %, round / flat strip armouring of cables, inner / outer sheath confirming to is:5831in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench / cable tray ( with cable tie ) includingtesting etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810.for additional technical parameters of product / work refer annexure a attached with this bsr 192 6.0 sq. mm 193 4 core 194 10.0 sq. mm 195 4 core 196 16.0 sq. mm 197 4 core 198 35.0 sq. mm 199 3.5 core 200 70.0 sq. mm 201 3.5 core 202 95.0 sq. mm 203 3.5 core 204 185.0 sq. mm 205 3.5 core 206 add extra for laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv gradedirect in ground including excavation of trench of size 75 cm ( depth ) x 35 cm ( width ) , with procedure as per followingpoints: ( a ) make a river sand bed of height 125 mm along the trench, ( b ) lay the cable in the middle of the trench, ( c ) provide river sand bed of height 125 mm on top of the cable, ( d ) lay the protective common burnt clay f.p.s. bricks of class designation 75 / sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( approx. 9 no. bricks per mtr. ) , ( e ) backfill the excavated soil leaving 300 mm from the ground level, ( f ) lay the cable warning tape and again back fill the remaining portion of the trench upto the ground level and compacting the earth 207 add extra for laying of one number additional pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv gradedirect in ground in the same trench in one tier horizontal formation including excavation of trench of size additional 20 cm in width, with procedure as per following points : ( a ) make a river sand bed of height 125 mm along the trench, ( b ) lay another cable in middle of trench in such manner that spacing between another cable is 20 cm., ( c ) provide river sand bed of height 125 mm on top of the cable. ( d ) lay the protective common burnt clay f.p.s. bricks of class designation 75 / sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( approx. 9 no. bricks per mtr. ) , ( e ) backfill the excavated soil leaving 300 mm from the ground level, ( f ) lay the cable warning tape and again back fill the remaining portion of the trench upto the ground level and compacting the earth. 208 supplying and making one end termination with nickel plated heavy duty brass single compression gland ( as per is 12943 1990 ) ) sibg type consisting of check nut, gland body, metal washer ( 3 nos. ) , outer seal rubber ring, compression nut, heavy duty aluminium lugs ( as per is 8309 1993 ) duly crimped with crimping tool, pvc tape as peris 8337 1976offollowing size ofpvc insulated & pvc sheathed / xlpe aluminium conductor cable of 1100 volt grade as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 209 3.5 x 185.0 sq.mm 210 3.5 x 95.0 sq.mm 211 3.5 x 70.0 sq.mm 212 3.5 x 35.0 sq.mm 213 4 x 16.0 sq.mm 214 4 x 10.0 sq.mm 215 4 x 6.0 sq.mm 216 supply, fabricating & installing following sizes of perforated hot dipped galvanized iron cable tray ( galvanized thickness not less then 50 microns ) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees, cross members and other accessories as required and duly suspended from the ceiling with gi suspenders including gi bolts & nuts , fastners, supports etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 217 150mm x 50mm x 1.6mm 218 p / l of double wall corrugated hdpe pipe confirming to is : 16205 p 24, stiffness class750 n, externally corrugated and having smooth surface insidewith hdpe coupler, elbow, teeat required depth below the ground for laying cable of followingnominal outer dia.mfr test reportfrom nabl accrediated is to be submitted. ( excavation of earth& back filling with compaction is to be paid extra ) all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 219 50 mm 220 110 mm 221 plate earthing as per is:3043 withcopper earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying3 mtr. below the ground level with 20mm dia. g.i. b class watering pipe , including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke / charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 222 supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % copperthickness ( 250 microns ) andconfirming toul 467, is / iec 62561 2of following size and length and as per point mentioned ( a ) , ( b ) , [ c ) , ( d ) , ( e ) below : 223 ( a ) bore a hole of dia. 100 mm of required length, place the rod in the centre of hole 224 ( b ) filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, cpri / erdatested with rms capacity of minimum 30 ka for withstanding 1 second .to ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. the compound shall be tested form nabl acredeated labfor lowresistivity ( less than 0.12 ohm meter ) & high conductivity in nature with carbon as a major contentas per referance of is 3043 1987, ieee 80 2013 ( clause 14.5d ) , ieee 837 & ier 1956 with latest amendemnts 225 © connect the rod with copper strip / conductor / wire with suitable clamp made from tinned copper and ss 304 bolt 226 ( d ) place heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height250 to 300 mm. 227 ( d ) testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 228 ( e ) test certificatesfor confirming above standards from oem is mandatory. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 229 25 mm thick and 3 mtr. long 230 supply & laying following size earth stripin horizontal or vertical run in surface by means of earth strip dmc insulatorincluding riveting / soldering / welding, jointing shall be done by overlapping and with 2 set of brass ( for cu strip ) / gi ( for gi strip ) nut bolt & spring washer spaced at 50cm making connection etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 231 25mm x 3mm g.i. ( hot dipped ) strip 232 50mm x 6mm g.i. ( hot dipped ) strip 233 40mm x 6mm copper strip 234 supply & laying following size b class , g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor / strip / cable in ground / surface / recess as required.all as per pre approved by engineer in charge. ( earth excavation will be paid extra ) all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annex ure a attached with this bsr . 235 50 mm dia. 236 65 mm dia. 237 80 mm dia. 238 100 mm dia. 239 150 mm dia. 240 supply & laying following size earth wire in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection with gi / cu purity purity >95%thimble etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 241 8 swg g.i. ( hot dipped ) wire 242 supply, drawing and testing of 4 pair, 23 awg solid bare copper wire insulated with pvc, utp ( unshielded twisted pair ) , category 6, class e, 100 ohm impedance, indoor cable as per latest ammendments of ansi / tia / eia 568 , the copper conductors should be balanced twisted in pairs, seperated by a cross member fluted pair divider & protected bypvc jacket. certified performance in a 4 connector configuration upto 100 mtrs channel requirements & transmission frequencies up to 250 mhz. in existing ms / pvc conduits / casing capping including making connections to information outlets and patch panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 243 supply and installation of unsheilded / 360 degree sheilded information outlets made of high impact plastic body with abs, fr grade halogen free material with provision for protection against dust in jack, suitable for cat 6 / 6a application complying to latest ammendments, according. to cat. 6 / 6a channel, it should support channel as well as components requirements of cat.6 / 6a standards at frequencies of up to 250 to 500 mhz. cat 6 / 6a unshielded / shielded jack should be suitable to terminate 4 pair, 23 / 24 awg solid / stranded wire diameters, using 100 ohm unshielded / shielded balance twisted pair cable, the jack should have tooless / impact termination on reliable copper tin plated insulation displacement contact, with easy lock mechanism, it supports iec 60603 7 4 and complied with ansi / tia / eia 568 c.2 standard. jack should be rj11, rj12 & rj45 compatible. should support ethernet 1.2 gb / s atm, digital video and broadband / baseband analog video, voice over internet protocal ( voip ) specifications in existing modular / ms boxes along with necessory connections as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 244 cat 6, un sheilded information outlet 245 supply & fixing of square faceplate for flush / surface mount information outlets single / dual or quad aperture , material should bepc+abs body, suitable for rj45 unshielded / shielded connection modules. should match with i. o. oem. dimensions should be 86mm x 86mm as required complete in all respect.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 246 single aperture 247 supply, installation, testing and comissioning of rack mounted 19 1u, cat6 24 port loaded, 1.5 1.6 mm crs chasis, powder coated, sheet steel, made of plastic ( abs ) , modular patch panelswith rear cable management system and mounting hardware to mount the patch panel. should have port identification numbers printed / engraved on front of the panel. etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 248 modular patch panel loaded with cat 6 i / o 249 supply , installation and testing of 4 pair, 100 ohm impedance, cat 6 / 6a / class e / ea patch cords should be constructed of minimum 23 / 24 awg, stranded bare copper cable with frpvc / lszh jacket, with an enhanced performance by factory moulded rj45 connectors with strain relief boots as per ansi / tia / eia 568 c.2 suitable for cat 6 / 6a application complying to latest ammendments category 6 / 6a standards, according. to tia568c.2, iso / iec 11801, en 50173, iec 60603 7 51, en 60603 7, ieee 802.3an minimum requirement for 1g base t to 10g base t performance. patch cords shall be straight thru cable compatible with both t568 a and t568 b wiring schemes, should support ieee 802.3af / ieee 802.3at for poe applications, minimum 750 to 1000 mating cycles in plug contacts for long durability, should support ethernet 10gbase t, 1.2 gb / s atm, token ring 4 / 16, digital video and broadband / baseband analog video, voice over internet protocal ( voip ) .all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 250 cat 6, u / utp ( unscreened / un sheilded twisted pair ) patch cord 251 1 mtr 252 2 mtr 253 supply & installation of ip 20 & ik 08 , ul listedwall mounted double section communication enclosure ( rack ) made from powder coated ( 60 to 80 micron ) crca sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door, vertical mounting rail 1.6 mm with umarking , with all round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. accessories like: 1 no of 19 1u horizontal cable manager, 1 no of 90 cfm 230v ac fan with 1 mts long cable, mounting hardware , 1 no of 19 1u, mountable socket strips with 5 nos of 5a universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with suitable anchor fastneretc as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 254 15 u rack with width 600 mm & depth 400 mm + 100 mm 255 supply & installation of ip 20 & ik 08 , ul listed communication enclosure ( rack ) made from powder coated ( 60 to 80 micron ) crca sheet, vertical mounting rail 1.6 mm with umarking, front sturdy sheet steel frame folded from one piece and welded with 5mm toughened glass door, with all round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, set of 75 mm height 4 castors, 2 of which have brakes, accessories like: 5 nos of 19 1u horizontal cable manager, 2 nos of vertical cable managers, 1 no. keyboard tray, 4 nos of 90 cfm 230v ac fan with 1 mts long cable, mounting hardware , 2 no of 19 1u, mountable socket strips with 6 nos of 5a universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 256 27 u rack with width 600 mm &depth 800 mm 257 supply , installation, testing and comissioning ofmanaged layer 2 intelligent 10 / 100 ethernet switch providing 24 x 10 / 100 / 1000 mbps giga ethernet ports / with min 2 sfp giga ports ( provision for fiber giga connectivity ) with related lan base software including making connections etc as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 258 providing & laying xlpe insulated three core armouredaluminiumcable for working voltage 11 k.v. ( e ) confirming is :7098 p 2withh4 grade electrolyticaluminium conductor confirming to is: 8130 class 2 of purity >99.6 %, insulation screening: extruded semiconducting compound followed by helically wrapped copper tape, round / flat strip armouring of cables , inner / outer sheath pvc type st 2 confirming to is:5831in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench / cable tray includingtesting etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810 all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 259 3 core 185.0 sq.mm 260 add extra for laying of one number xlpe power cable of 11 / 33 kv ( earthed ) voltage gradedirect in ground including excavation of trench of size 120 cm ( depth ) x 35 cm ( width ) , with procedure as per followingpoints: ( a ) make a river sand bed of height 125 mm along the trench, ( b ) lay the cable in the middle of the trench, ( c ) provide river sand bed of height 125 mm on top of the cable. ( d ) lay the protective common burnt clay f.p.s. bricks of class designation 75 / sand stone slabs of 50 mm thicknessand 225 mm wide just above the sand bed vertically across the cable ( approx. 9 no. bricks per mtr. ) , ( e ) backfill the excavated soil leaving 300 mm from the ground level, ( f ) lay the cable warning tape and again back fill the remaining portion of the trench upto the ground level and compacting the earth 261 providing & making heat shrinkable type indoor / outdoor / straight through terminations / joint kitsuitable for11 kv / 33 kv ( earthed ) cable with required components, prepration of cable ends. type test report should be as per is13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streightthrough joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. crosslinking shall be done out side factory with e beam / peroxide technology. extrusion process shall be in house oem within same vicinity. includingtesting etc. as required of following sizes. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 262 11 kv end termination kit indoor type 263 3 core 120 / 150 / 185 sq.mm 264 11 kv end termination kit outdoor type 265 3 core 120 / 150 / 185 sq.mm 266 providing & fixing of iso certified company made on load change over switch, front handle operated, four pole 415 v as per pwd specificationfor electrical works conforming to is / lec 60947 3 : 1999 including connections , testing etc. as required .in the following rating.appropriate type test certificate / oem test report shall be submitted .all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 267 open execution type 268 200 a 269 sitc of ip 42 and general construction confirming to is:8623 : 1993, wall / free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andother parameters requiredas per point ( a ) , ( b ) , ( c ) , ( d ) , ( e ) , ( f ) , ( g ) , ( h ) as below: 270 ( a ) thickness of crca sheet shallbe 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 271 ( b ) complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel.the panel having pe foam / neoprene rubber gasket of not less than 3mm thickness , required hardware , concealed hinged door with key type locking arrangement for equipment / switchgear earthed with 2.5 sq.mm braided copper wire. 272 [ c ) interconnection between bus bar and switchgears / cable shall be rigidly supported and made out by flexible copper wires ( up to 63 amp ) and by solid bus bar ( >63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only.all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgearis to be paid extra ) 273 ( d ) wiring between components within switchgear and incoming / outgoing cableshall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 274 ( e ) all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be ‘point to point’ ( no wire splitting or tee connections ) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 275 ( f ) floor mounted panel shall be mounted on base frame of ismcchannel size 100 x 50 x 5 mm ( to be paid extra ) 276 ( g ) tests: the insulation resistance ( with 1000 v megger ) and high voltage power frequency test ( by applying a voltage of 2.5kv for one minute ) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. the insulation resistance shall not be less than three megaohm. ct secondary current injection test shall also be carried out. 277 ( h ) only outer surface area on all sides shall be measured & panel to be fabricated only from cpri approved fabricator only ( cpri test certificates to be submitted ) all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 278 supplying and fixing of aluminium ( iec 60105 iso 209 1, 2 ) / copper ( iec 60028 ) bus bar by means of smc / dmc type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 279 electrolytic grade aluminium bus bar 6010 grade 280 providing & fixing of is: 13875 & iec :61326 confirming led digital type ( up to 500 ) v range volt meter / direct ammeter / ct oertated ammeter / frequency meter / kwh meter / multi function meter / power analyzer of class 1 accuracyas per is : 1248 of size 96mm x 96 mm including making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 281 threephase amp+hz+pf+kw+kva+kvar+t.energy+thd i, thd v & run hrs 282 providing & fixing of bis approvedcurrent transformeras per pwd specification for electrical works , isi marked as peris 2705 1992 / conforming to iec 60044 1, with secondary terminalof ct shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredcurrent transformer ring type tape wound / resin cast wound as per is 16227 with, accuracy cl, ct ratio and burden as specified. isf<=5, cu cross section of secondary wire 1.5sqmm ( minimum ) , including all necessary support in existing panel including connection etc. as required . all as per pre approved by engineer in charge.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 283 ring type tape wound ct 284 c t class 1, ratio 200 / 5 to 300 / 5, burden 10 va 285 c t class 1, ratio 400 / 5 to 1200 / 5, burden 15 va 286 providing & fixing ofcam operated rotary ( auto / manual ) switches on existing panel with 2 way and off position using high grade engineering materialto international standards with cam assemblyinsulation of glass filled polyamide with high tracking index. for reliable and stable electrical and mechanical endurance double butt contacts with silver bi metal on copper should provided . contact assembly is of operating temp range 25 degree c to 55 degree c, frequency upto 10 khz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles / hour and electrically 10, 000 operations at 100% rated duty for 100 cycles / hour including making connection etc.as required . all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 287 32 amp 288 providing & fixing of110 / 220 v, unibody led indicatinglamp iec 60947with integral circuit, ip 65 above panel &ip 20 terminal block, approx. body dia for panel not less then 20 mm, length min. 50mm, front led cover dia min.29 mm, contact material phospher bronze for led, pcb contacts shall be ofbrass ( tin plated ) , impulsedielectric tested for 2.5 kv, rated insulation resistance shall be 100 m ohm at 500vdcincluding connection etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 289 red / yellow / green colour 290 blue / white colour 291 providing & fixing of electricalinsulating rubber matts as per pwd specification for electrical works, isi marked confirming to is: 15652 / 2006with one sideanti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 292 11 kv, class b 2.5 mm thick with proof voltage 22 kv ac ( rms ) and break down voltage45 kv ac ( rms ) 293 providing & fixing of self healing ip20 mpp type shunt capacitor ( banks ) conforming to is:13340 41 / iec :831 1&2 or iec : 60831 1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( psd ) and shall have dissipation factor less than 0.0025 at 50 hz, operating loss less than 0.30 watt per kvar. min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, llife expectancy greater than 100000hrs ( temp class 25 d ) in 440 v / 480 v capacitor and for 525 v should life expectancy minimum 1, 65, 000 hrs ( temp class 25 d ) including making connections, testing etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 294 heavy dutythree phase 525v, 50 hzcylindrical typecapacitor ( bank ) 295 providing & fixing of ip54 microprocessor based 3 ct’s for all 3 phasesensing compensationpower factor correction relay size 139mm x 139 mm, operating voltage 415 / 440 v, iec / en 61000 6 ( 2&4 ) having 3 ct sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c / k setting according to targeted power factor setting, the relay shall havedigit display unit for display of real power factor, targeted power factor, lag / lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with rs 485, indication of switching on units, auto / manual status, and shall have over load protection, no volt release , having multi parameter like kw, kva, kvar, rms value, step switching time 2 sec to 1800 sec. lead & lag parameters, metering facility and3 no. class 0.5 cast resinct ( refer ct specs in this chapter ) for sensing the relay including making coonection with 1.5 sq.mm copper wire etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 296 12 to 14 stage 297 providing & fixing ofac operated heavy duty 230 / 440 volt power contactor as per pwd specification for electrical works, isi marked is / iec 60947 4 1 : 2000 having provision of mechanical interlocking, auxilary contacts, din rail mounting type including making connections, testing etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 298 3 pole power contactorswith following ac 3 rating 299 40 amp 300 providing & fixing of440 volt 3 pole capacitor ( ac 6 b ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors / reactors to limit the inrush current as per pwd specification for electrical works, is / iec 60947 4 1 : 2000, insulation voltage 1000v, impulse withstand voltage 8 kv, din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 301 up to 6 kvar 302 10 kvar 303 20.0 kvar 304 providing & fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and ac1 rating of 16 20 amperes including making connection, programming conforming to iec 60730 1 and 60730 2 7 etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 305 one day & week reserve ( digital type ) 306 sitc of3 / 4pole current limiting moulded case circuit breaker ( mccb ) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440 / 415 v, 50 hz; o / l & s / c settings , conforming to is / iec 60947 p 2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push ( test ) to trip, trip time less then 10 ms under s / c condition, breaking capacity ics = 100% icu. u imp =8 kv, rated insulation voltage690 v.provision for uvr , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.oem shall have submitnabl / cpri / erda accrediated lab type test certificate before execution all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 307 3 pole mccb with thermal magnetic release 308 160 amp , 25 ka, adjustable o / l & adjustable s / c setting, 309 4 pole mccb with thermal magnetic release 310 up to 100 amp , 25 ka, adjustable o / l & adjustable s / c setting, 311 125 amp , 25 ka, adjustable o / l & adjustable s / c setting, 312 160 amp , 25 ka, adjustable o / l & adjustable s / c setting, 313 200 amp , 25 ka, adjustable o / l & adjustable s / c setting, 314 250 amp , 35 ka, adjustable o / l & adjustable s / c setting, 315 400 amp , 35 ka, adjustable o / l & adjustable s / c setting, 316 s i t c of star ratedaluminium wound distribution transformerof following rating 11 / 0.433kv delta star connected, vector group dyn 11, onan cooled & as per bee star 1 & bis approved as per is 2026 1977 & lossesas defined as per 2014 ( fourth revision ) level 1 . including standardaccessories like conservator, silica gel breather, radiator, fins, ht cable box & lt cable boxes, temperature rise in winding / oil 35 40 degree c upto 200 kva & 40 45 degree c for above 200 kva, isi marked drain valve, dial type temperature gauge, first filling of transformer oil as per is :335 1953, epoxy based paint, including carrying of pre commission testing & charging of transformer complete in all respect . 317 the transformer shall be subjected to routine factory tests ( as per is:2026 and is:1180 ) including testing from ctlof discombefore charging of transformer & complete installaion must be certified from electrical inspectorate office as per indian electricity rule, ( ctl testing charges and electrical inspection charges shall be reimbursed by the department to the contractor ) . all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 318 250 kva with off ltc ( +5% to 10% @ 2.5% ) 319 sitc of 11kv 630 amps 21ka for 3 sec. sf6 insulated, outdoor duty ( ip54 ) , extensible / non extensible typering main unit ( rmu ) manually operated in combination ofvcb modules andload break switch consisting of copper busbar in sf6 insulated 304 ( non ferrite non magnetic grade ) stainless steel enclosure of thickness 2.5mm with manometer.the hv switchgear and control gear should be confirming to iec 62271 100, iec 62271 200 2003 & iec 60694 1996. the rmu should be internal arc tested for 21ka for 1second with iac afl classification for gas tank. vacum interrupter of vcb should be rmu manufacturer’s own make.each feeder of rmu should have voltage presence indicator. . and compring offollowings: 1 no. microprocessor based self powered numerical relay with over current / earth fault & short circuit protection with each vcb feeder. 3 nos. protection ct shall be of burden 2.5va, ratio 50 / 1a, class of accuracy class 5p10for o / c and e / f protection for each vcb. 1 no. manometer for each tank, 1 nos. fault passage indicator, right angle boots for all the feeder modulesall the type test certificates as per iec from third partynabl / cpri / erda accrediated lab to be submitted. ( cost of rcc foundation / steel structure to be paid extra ) all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr 320 non extensible 3 way rmu with 1 no. vcb & 2 no. load break switch 321 sitc of ht metering cubical panel as approved by discoms fabricated out of 18 swg crca sheet steel in two compartment & ms angle of size 60mmx 6mm having provision for following: ( i ) provision for fixing trivector / import export meter ( to be supplied by discoms ) ( ii ) provision for fixing of combined ct pt set with copper strip for connection ( to be supplied by discoms ) , ( iii ) test terminal block, ( iv ) 6mm thick bakelite sheet on all sides, ( v ) 3 / 6 corex 1.5 / 2.5 sq.mm copper cable for interconnections, etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 322 sitc of radiator cooled and turbo charged silent dg set ( as per latest cpcb emissionnorms ) havingspecifications as per a, b, c, d, e, f, g, h & i 323 a ) 1500 rpm diesel engine conforming to bs:649 / 5514 of suitable bhp ( up to 82.5 kva 6 cylinder or below required, 125 kva & above ratings 6 cylinder or aboverequired ) capable of taking 10% over loading for one hour after 12 hours of continuous operation., dry exhaust mainfold with hospital grade silencer and catalytic convertor ( isolated from main dg chamber ) , up to 3 m exhaust piping ( with lrb insulation & alum. cladding ) as required . 324 b ) ac brush less spdp alternator conform to bs 5000 ( part 99 ) or is / iec 60034 1. . alternator shall be self regulated with standard alternator protection ( over voltage , over speed & under voltage, under speed warning & shutdown ) .engine & alternator mounted on a common base frame & coupled through a flexible coupling or close coupled 325 c ) cpcb / arai approved standard canopy with weatherproof, powdercoated accoustic enclosure for dg set for sound attenuation fabricated from 1.6 mm crca sheet steel ( structure ) with sidewall fabricated from 1.6 mm crca sheet & filled with glasswool ( 96kg / m3 ) / foam. as per is8183 the doors of 28 / 40 / 50 / 85mm thick as perrating and fabricated from 1.6mm crca sheet packed with accoustic material, all doors / opening are sealed with neoprene / epdngaskets. the dg set has inbuilt / external in fuel tank to run 6 to 8 hrs as per oem standard, with protection and tripping of dg set against temperature of more than 50 degree centigrade. 326 d ) electronic / mechanical governor, manual & electric start , batteries with battry charger, engine instruments panel, avm pads all controls for operation of dg set are from outside the enclosure with dg control panel having microprocessor based genset monitoring like running hour, rpm, low lube oil tripping & control system, panel mounted mccb / acb of suitable rating, ammeter, voltmeter, pf meter, frequency meter, kwh meter, digital fuel display meter, ind.lamps etc. mounted inside enclosure , visible and accessible from outside. the enclosure should be suitable for following capacity dg sets and alternator. noise level shall be less than 75 db at a distance of 1 mtrs. duly certified by authorised agency etc. complete in all respect of following capacity : 327 e ) ( i ) accoustic glass wool wall thickness should not be less then 40mm and not less then 20mm pu foam upto rating 100 kva. ( ii ) .accoustic glass wool wall thickness should not be less then 65mm and not less then 50mm pu foam upto rating 250 kva. ( iii ) accoustic glass wool wall thickness should not be less then 100mm forrating above 250 kva. 328 f ) first filling of the fuel tank shall be done by contractor and the prevailing fuel cost at that time shall be reimbursed to the contactor by department. 329 g ) servicing contract of dg set from oems authorised service dealer as per oem guidelines during the dlp period shall be done by contractor including all consumables, actual charges shall be reimbursed to the contractor by end user department. 330 h ) manufacturer / oem must have its authorized service dealer in rajasthan. which can provide service within 6 hours of compalint registration. 331 i ) dg set will be offered for inspection and testing at manufacturers works in presence of departmental engineers. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 332 40 kva at 0.8 pf 415v 50hz 3 ? 333 sitc of plc based auto main failure ( amf ) panel fabricated from crca sheet steel 2 mmthick , powder coated finish , engine start & stopcommands, control relays , ammeter & voltmeterwith selector switches, control & 2 nos 4 pole power contactors with 2 no. of required size 4 pole mccb, timers, electronic hooter , visual & alarm indication for faults, ups, operator interface panel complete in all respect suitable for following capacity dg sets: appropriate test certificate / report of product / accessories from oem / panel manufecturer shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 334 20 to 40 kva 335 supply & fabrication steel structure with ms channel / angle / joist / ismb / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as requiredcomplete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 336 providing and fixing welded mesh / expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 x 50 x 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 ( 30x30x45cm ) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 337 earth work in excavation / by mechanical means ( hydraulic excavator ) / manual means over areas ( exceeding 30 cm in depth, 1.5m in width as well as 10 sum on plan ) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed: 338 random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 ( 1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size ) upto plinth level with cement mortar 1:6 ( 1 cement : 6 sand ) . 339 providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement all work up to plinth level 340 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) 341 plaster on new surface on wall in cement sand mortar 1:4 including racking of joints etc. complete fine finish : 342 20mm thick 343 finishing wall with water proofing cement paint of approved brand and manufacture and or required shadetogive an even shade including all scaffolding: 344 new work ( two or more coats applied @ 3.84 kg / 10 sqm ) . 345 sitc of single stage, water cooled, high speed ( 2880 rpm ) , horizontal, centrifugal, openwell submersible pumps set pre filled with coolent water and fitted with mechanical seal t / c vs t / c, thrust bearing shall be ofcarbon + s.s.the stator body of single phase pumpshall be of ss and rest of all shall be of cast iron. all casting parts should be cathod electro deposition ( ced ) coated and other construction material should be confirming to is : 14220: 2018 . the overall performance of pump shall confirm to bee energy efficiency level of 3 star. valid bee certificate from oem must be submitted for the same. motor should be ie2 class as per iec 60034 2 1: 2007, iec 60034 30: 2008, & is12615:2011, including making connection etc as required complete in all respect. oem shall have submitnabl / cpri / erda accrediatedlab type test certificate before execution. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 346 5.0 hp, 3 ø, ( 14 28 ) mtr, ( 995 500 ) lpm 347 sitc of contactoroem fabricated dol / star delta starter panel with switchgear selection as per type 2 cordinatiom chart andmade out from 1.6 mm thick powder coated crca sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, illuminated on / offpush buttons, ammeter, voltmeter, indicating lamps etc.suitable for following rating motors complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 348 for three phase submersible / mono block pump 349 3.0 hp to 5.0 hp ( dol starter ) 350 part b non bsr items based on market rate 351 sitc ofro water system with filtration stage = particulate filter membrane life enhancer filter sediment filter pre carbon filter ro membrane filter post carbon filter, input power rating 230 v ac , 50 hz, percentage of rejection tds 90% or better having following features ( a ) double purification by ro with ess or latest technology with tds indicator ( b ) .spin welded ro membrane housing to prevent tempering ( c ) . push fit components for leak proof performance ( d ) . fully automatic operation with auto start and auto off ( e ) . ss construction for corrosion free lifespan ( f ) . equally suitable for water from all bore wells, , overhead storage tanks, water tankers and even municipal taps ( g ) ro membrane flushing auto flush @ every start , every stop and every one hourof working for one minute. complete in all respect with following capacity. approved make:eureka forbes, kent, au smith, ion exchange, pentair. 352 purification capacity 50 lph, duty cycle 270 500 liters / day, 353 sitc of dome ip ir cctv cameras: network h.265 2mp ( full hd ) megapixel high frame rate mini dome camera with built in microphone:2mp ir dome camera with metal body and built in mic: 1 / 2.8 progressive scan cmos; resolution: 1920 × 1080@30fps or better; colour: 0.01 lux @ ( f1.2, agc on ) or better, h.265+ compression or better; 120 db true wdr or better; fixed 2.8 / 4mm lens; built in mic; 3d dnr; 40m ir range or better, triple streams; blc, 3d dnr, hlc; line crossing detection, intrusion detection; scene change detection; face detection; anti flicker, heartbeat, mirror, password protection, privacy mask, watermark, ip address filter; onvif ( profile s, profile g ) , isapi; built in micro sd / sdhc / sdxc slot, up to 128 gb or better; operating condition: 30 °c to +60 °c; ip67; 12dc & poe; certificate of compliance: ul, ce / fcc, bis, rohsapproved make: samsung / hikvision / panasonic / infinova / cp plus / dahua / honeywell 354 sitc of ip ir cctv bullet outdoor camera: network h.265 2mp ( full hd ) megapixel high frame rate ir bullet camera ( outdoor ) with metal body, 2mp full frame low light ir bullet camera: 1 / 2.5 progressive scan cmos; resolution: 1920 × 1080 or better; color: 0.002 lux @ ( f1.2, agc on ) or better; slow shutter; fixed 3.6 mm lens; triple streams; 3d dnr; 120db wdr; 50m ir range or better; line crossing detection, intrusion detection, object removal detection, unattended baggage detection, scene change detection; face detection; anti flicker, heartbeat, mirror, password protection, privacy mask, watermark, ip address filter; onvif ( profile s, profile g ) , isapi; roi; support micro sd / sdhc / sdxc card ( 128g ) , local storage and nas ( nfs, smb / cifs ) , anr; operating condition: 30 °c to +60 °c; ip67; 12dc & poe; metal body; built in junction box for cable management; certificate of compliance: ul, ce / fcc, bis / rohs approved make: samsung / hikvision / panasonic / infinova / cp plus / dahua / honeywell 355 sitc of raid 5 supported 32ch nvr with upto 48 tb hdd support 32ch ip inputs; dual os for redundancy; support anr technology;320mbps incoming bandwidth, supports up to 12mp full channel recording; support h.265 compression; 16ch syncronised playback @1080p; support raid 5; n+1 hot spare system; support 3rd party cameras; 4k output; minimum 8 sata hdd slots; each slot should suppport upto 6tb hdd; e sata interface; dual gigabit self adaptive ethernet interface; serial interace; usb interface; alarm in / out;dual power supply ( all cameras and storage nvr should be of same make for the smooth functioning of the system ) . certificate of compliance: ul, ce / fcc, bisapproved make: samsung / hikvision / panasonic / infinova / cp plus / dahua / honeywell 356 sitc of 3.5 6tb surveillance hard disk ( makes: seagate / wd / toshiba ) 357 sitc of workstation latest intel® i5 processor, with 17 led monitor screen intel chipset motherboard, 08 gb ram, 1 tb sata hdd at 7200 rpm, with 4gb gpu type higher end graphic card for h.265 compression technique with dual display ports / dvi / hdmi port, giga lan card, wireless keyboard, wireless optical mouse with original license windows software of approved makes: lenovo, hp, dell. 358 sitc of 55 flat smart screen hd profesional led with remote control and wall mount unit / floor stand complete with making connections etc of approved makes: lg, samsung, panasonic. 359 sitc of 5 kva 1 phase input, 1 phase output advance dsp controlled ups with igbt based rectifier, lcd display, double conversion / digital signal processing ups, with isolationtransformer, with 26ahx x 16 nos smf batteries for min 30 min back up, with ms rack for barreries and required cabling for incoming & outgoing connection of approved makes: numeric, eaton, emerson, apc. 360 supply, installation, testing & commissioning of managed layer 2 intelligent ethernet poe switches providing 08 x 10 / 100 / 1000 fast ethernet poe ports 67w or better and 2 dual purpose uplink ports ( provision for copper / fiber giga connectivity ) all switches & related fiber modules should be of same make & category for seamless integration with each other of approved makes: cisco catalyst series or equivalent in avaya, juniper ) 361 p & f of early streamer emission type lightning arrester on gi mast with air terminal configured as spheroid which is comprised ofseparate electrically isolated 4 panels surrounding an earthed central finial, the terminal shall be tested by cpri for impulse current of 45 ka ( 8 / 20 sec ) with 5 positive & 5 negative impulse, the arrester having following protection radius at level 1 approved makes :lpi ( australia ) , lpsfr ( france ) , sudafix ( uk ) , ef ( switzerland ) , abb 362 30 48 mtr. 363 s & laying of p.v.c. / xlpe insulated & p.v.c. sheathed down conductor of 70 sq.mm single core insulated flexible copper cable confirming to is:1554 p i / is :7098 p i of 1.1 kv withelectrolytic gradecopper made of copper rodsconfirming to is 613 1964, of purity >99.7 %, inner / outer sheath confirming to is:5831 with accessories as required. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810approved makes: polycab, rr, finolex....

Urban Improvement Trust - Rajasthan

36206657 supply of necessary material for road light repair in uit area, alwar providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed un arrmoured aluminium cable confirming to is:1554 p i / is :7098 p i of 1.1 kv with h4 grade electrolytic aluminium conductor confirming to is 8130 of purity >99.6 %, inner / outer sheath confirming to is:5831 in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench / cable tray ( with cable tie ) including testing etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810. for additional technical parameters of product / work refer annexure a attached with this bsr 11.1.1 4.0 sq. mm 1000 61.00 mtr. 61000 11.1.1.1 2 core 11.2 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed arrmoured aluminium cable confirming to is:1554 p i / is :7098 p i of 1.1 kv with h4 grade electrolytic aluminium conductor confirming to is 8130 of purity >99.6 %, round / flat strip armouring of cables, inner / outer sheath confirming to is:5831 in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench / cable tray ( with cable tie ) including testing etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810.for additional technical parameters of product / work refer annexure a attached with this bsr 11.2.3 10.0 sq. mm 11.2.3.3 4 core 1000 192.00 mtr 192000 11.2.4 16.0 sq. mm 11.2.4.3 4 core 800 232.00 mtr 185600 2 19.24. supplying and drawing of xlpe insulated lt aerial bunched aluminium conductor cable confirming to is 14255 / 1995 and is 398 ( pt 4 ) / 1994 and as per discom specs. on existing cross arms through i hook with all necessary t&p required including binding and twisting etc. complete in all respect as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 3 19.24.2 1 x 25 sq. mm. + 1x25 sq. mm. ( insulated ) 1000.00 rs.63.00 mtr. rs.63, 000.00 4 18.12 providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket / pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc ( uv stablization report submitted for uv cover ) / toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm / wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% , thd ( i ) <10% humidity 10% to 90% rh working temp 5c to 45c . driver current <750ma. the luminaire shall be bis certified and trade mark certified. life expectancy equal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min ≥ 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark / name engraved / embossing on die cast housing to allow traceability / authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 / lm80 ) certificate / report with liable warranty of product / accessories from oem shall be submitted. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 5 18.12.1 led street light fixture with minimum lumen output 2450 lm 200.0 2554.0 each rs.510, 800.00 9 8.1 sitc of ip 42 and general construction confirming to is:8623 : 1993, wall / free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point ( a ) , ( b ) , ( c ) , ( d ) , ( e ) , ( f ) , ( g ) , ( h ) as below: 10 sitc of ip 42 and general construction confirming to is:8623 : 1993, wall / free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point ( a ) , ( b ) , ( c ) , ( d ) , ( e ) , ( f ) , ( g ) , ( h ) as below: 11 ( a ) thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided urban improvement trust, alwar u;kl { k s= vyoj kgj e sa jk sm ykb zv dh ejeer g sr q vko;d lkeku vki qfr z ckcr ~ schedule ( as par pwd electict bsr 2022 ) 12 ( b ) complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam / neoprene rubber gasket of not less than 3mm thickness , required hardware , concealed hinged door with key type locking arrangement for equipment / switchgear earthed with 2.5 sq.mm braided copper wire. [ c ) interconnection between bus bar and switchgears / cable shall be rigidly supported and made out by flexible copper wires ( up to 63 amp ) and by solid bus bar ( >63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgear is to be paid extra ) ( d ) wiring between components within switchgear and incoming / outgoing cable shall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the ( e ) all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be ‘point to point’ ( no wire splitting or tee connections ) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. ( f ) floor mounted panel shall be mounted on base frame of ismc channel size 100 x 50 x 5 mm ( to be paid extra ) 13 d ( g ) tests: the insulation resistance ( with 1000 v megger ) and high voltage power frequency test ( by applying a voltage of 2.5kv for one minute ) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. the insulation resistance shall not be less than three megaohm. ct secondary current injection test shall also be carried out. 14 ( h ) only outer surface area on all sides shall be measured & panel to be fabricated only from cpri approved fabricator only ( cpri test certificates to be submitted ) all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 15 panel of size 3x4x4= 2.04 sqm ( 1x2.04 ) 5.00 rs.5, 975.00 sq.mtr. rs.29, 875.00 16 18.18 providing & fixing of street light bracket made out from following size of b class , medium class g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with heavy duty pole clamp, saddles suitable fastners etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 18.18.2 25 mm dia....

Military Engineer Services - Rajasthan

36109207 repair and maintenance of internal electrification with fitting and fixture of otm zone f at mil station sri ganganagar, 1 taking down carefully aluminium point wiring ( light, fan, socket or power, bell complete fitting such as sockets, ceiling roses, pendants, batten holders, regulators and making good the disturbed surfaces of wall, floors, ceiling in cm 1:3 etc complete all as specified and directed by engineer in charge. 2 m & lfor concealed conduit point wiring complete for light on independent / combine boardwith cable 1.5 sqmm ( nominal area ) frlsh pvc insulated multistranded unsheathed copper conductor, drawn in and includingpvc concealed conduitpipe medium grade 20 mm dia, pipe hooks , elbows, juction covers and junction boxes , aftercutting in wall chasing for conduits and sinkings for sunkencast iron / pressed steelterminal boxes 60mm deep , suitable lengthand 1.20 mm thickness for mounting, switches, sockets, fan regulatorwith 3 mm thick plastic laminated sheet cover fixedwith brass screwed and cup washers, dulygrouting and painted with red oxide metal primer and making the gooddisturbed surfaces of wallin cm 1:3 with white wash or existing colour including provision ofcontinuousearth continuity conductoralong with point wiring of 1.5 sqmm copper pvc insulated cable for one light / fan point controlled by one switchand connected to commonearth dolly, complete all as specified anddirecedby the engineer in charge. 3 all as per srl item no 02 here in before but for one switch socket combination 5 / 6 amp on independent board complete all as specified and directed by engineer in charge. 4 all as per srl item no 02 here in before but for one three pin socket outlet 5 amp on same board with other switches complete all as specified and directed by engineer in charge. 5 all as per srl item no. 2 here in before but for one switch socket combinationt 6 pin 5 / 15 amps on independent board with copper conductor 2.5 sqmm complete all as specified and directed by engineer in charge. 6 all as srl item no. 02 here in before but for one light point controlled by two 2 ways switches complete all as specified and directed by engineer in charge. 7 all as per srl item no. 2 here in before but for call bell point complete all as specified and directed by engineer in charge. 8 m & lfor concealed existingconduit point wiring complete for light / fan on independent / combine boardwith cable 1.5 sqmm ( nominal area ) frlsh pvc insulated multistranded unsheathed copper conductor, drawn inpvc existing concealed conduitpipe medium grade 20 mm dia, pipe hooks , elbows, juction covers and junction boxes , and sinkings for new sunkencast iron / pressed steelterminal boxes 60mm deep , switches, sockets, fan regulatorwith 3 mm thick plastic laminated sheet cover fixedwith brass screwed and cup washers, dulygrouting and painted with red oxide metal primerincluding provision ofcontinuousearth continuity conductoralong with point wiring of 1.5 sqmm copper pvc insulated cable for one light / fan point controlled by one switchand connected to commonearth dolly, complete all as specified anddirecedby the engineer in charge. 9 all as per srl item no 08 here in before but for one switch socket combination 5 / 6 amps on independent board complete all as specified and directed by engineer in charge. 10 all as per srl item no 08 here in before but for one three pin socket outlet 5 amp on same board with other switches complete all as specified and directed by engineer in charge. 11 all as per srl item no. 8 here in before but for one socket outlet 3 pin 15 amps on independent board with 2.5 sqmm copper cable complete all as specified and directed by engineer in charge. 12 all as per srl item no. 8 here in before but for one light point controlled by two 2 ways switches complete all as specified and directed by engineer in charge. 13 all as per srl item no. 8 here in before but for call bell point complete all as specified and directed by engineer in charge. 14 s & f switch piano flush type 5 / 6 amps single pole one way complete all as specified and directed by engineer in charge. 15 s & f switch piano flush type 5 / 6 amps single pole two ways complete all as specified and directed by engineer – in charge. 16 s&f bell push flush type 5 amp complete all as specified and directed by engineer – in charge. ) 17 s&f electronic bell ac 230 volt single pole ding dong type complete all as specified and directed by engineer in charge. 18 s & f switch socket combination 5 pin, type 5 / 6 amps flush type complete all as specified and directed by engineer in charge. 19 s & f switch socket combination 6 pin, 15 / 16 amps flush type complete all as specified and directed by engineer in charge. 20 s & f socket outlet 5 pin 5 amps flush type complete all as specified and directed by engineer in charge. 21 s & f in replacement industrial socket metal clad plug and socket with mcbs single pole 20 amp complteall as specified and directed by engineer in charge. 22 s & f in replacement modular switch5 / 6 amps single pole one way, one module complete all as specified and directed by engineer in charge. 23 s & f in replacement modular switch socket combination 5 pin, type 5 / 6 amps5 in 1flush type including modular cover plate with frame complete all as specified and directed by engineer in charge. 24 s & f in replacement modular switch socket combination 6 pin, 5 / 16 amps flush type including modular cover plate with framecomplete all as specified and directed by engineer in charge. 25 s & f in replacement modular switch5 / 6 amps single pole two ways complete all as specified and directed by engineer – in charge. 26 s & f in replacement modular socket outlet 5 pin 5 amps flush type complete all as specified and directed by engineer in charge. 27 s&f in replacement modular bell push 5 amp complete all as specified and directed by engineer – in charge. 28 s & f in replacementmodular stepped type, fan regulator not less than 120 watt for ceiling fan 1200 / 1400mm sweep complete all as specified and directed by engineer in charge 29 s & f ceiling rose surface bakelite 65 x 50 mm three terminals complete all as specified and directed by engineer in charge. 30 s & f in replacement of existing light fitting withled batten with aliminium housing andintegrated electronic driver, 20 / 22 watt having input voltage ac90 300v, 50 hz , 6500k, and all other accessories including connection with flexiblecable copper conductortwin coreof size 23 / .2 mm upto ceiling rose / connectorcomplete all as specified and directed by engineer in charge. ( make:havells cat part no: lumilineplusbs20wled865spcss, bajaj cat part no.: bclsbal 20w cw , philips cat part no. bn021c led22s psu cw gr 31 s&fin replacement security light fitting led type 25 watt with all necessary acessories, clear transparent acrylic cover, prewire suitable to operated on 230 volt 50 hz ac & supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 2 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23 / 0.0076 complete all as specified and directed by engineer in charge ( make:havells cat part no: endurapearlsl25wled757sasytopcmp, bajaj cat part no. brlep 25w led wh, philips catpart no. brp042pled25cwslepsugr dx ) 32 s & fin replacement angle holder insulated body with back plate for conduit fittings complete all as specified and directed by engineer in charge. 33 s & f water tight bulk head fitting, comprising of connector galvanised cast iron back plate, weather proof enameled gallery , with electronic driver, ( latest design ) , 10 w , upper pvc body all as specified and directed by engineer in charge ( make:havells cat part no : hexaft10wled857ssymbopc, bajaj cat part no. bibwp 10w led, crompton cat part no. lbhp 10 cdl ) 34 s&fin replacement decorative wall light, brushed nickle finish fiturewith opal glass diffuser including 4 watt led filament lamp e14 base complete all as specified and directed by engineer in charge ( make havells cat part no: lhfoaic1tz1i040or equivalent make in bajaj, crompton 35 supply and fixing led light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 v ac decorative type with driver holder and led lamp including connecting up with three core flexible copper conductor cable of suitable size all as specified and directed by engr in charge. ( make : havells cat part no lumilineplusbs10wled865spcss, bajaj cat part no. bclsb 10 wh, philips cat part no. bn021 led12s 6500 psu gr ) 36 s & f speed regulator for ceiling fan 1200 / 1400mm sweepcomplete all as specified and directed by engineer in charge 37 s&f in replacementrecess mounting 2 x 2 feet 36 watt led luminaire with powder coated crca housing with leds, seamless front frame with high transmission acrylic cover and fixed electronic driver ( surge protector ) complete all as specified and directed by engineer in charge.make:crompton cat part no :lctlrne 36 fo cdl or equivalent make in havells, bajaj 38 s & f in replacement round / square recess mounted led edge lit slim downlight 12 wattwith die cast aluminum housing finished in premium white powder coating. efficacy 100lm / w complete all as specified and directed by engineer in charge.make havells cat part no.edgeprorddlr12wled857s, bajaj cat part no. bpslr 12w wh, crompton cat part no. lscrm 12w cdl 39 supply and fix in replacement led flood light 80watt , protected to ip65 with flat front toughened glass and fixed electronic driver ( surge protecter ) complete including fixing arrangments in ground / on pole complete all as specified and directed by engineer in charge .make havells cat part no. baybriteflare80wled857pwbbolt g, bajaj cat part no.bjfl 80w led i, crompton cat part no. lfl 80 cdl / 60 m 40 supply and fix in replacement ledhighbay luminaire 80w having fin ventilation technology for better thermal management and its cutting edge led technology seeks to various industrial applicaton complete all as specified and directed by engineer in charge . make: havells cat part no. iliosbayplushbp80wled857sp90dtopc, bajaj cat part no. bghb 80w led g v, crompton cat part no. lhb11 80 cdl / 60 m 41 supply & fixing in replacementled land scape light / bollard light 10w / 9 w with 900mm height extruded aluminium cylindrical section housing ip 65 rated complete with base & log bolt grafite grey epoxy cationic powder coated all accessories all as specified. and directed by engineer in charge . make: crompton cat part no lblsr 10 ww, bajaj cat part no bgbom 650 9w led or equivalent make in havells. 42 s & f in replacement ledsuspension light fitting 36 w ( fixture size : ( lxwxh ) in 1136x54x74 mm ) , aluminum extruded direct indirect light effect gives homogenous light distribution effect & enhances the visual comfort with joining kitaccessoriesand connecting to mains cable complete all as specified and directed by engineer in charge. ( make : havells cat part no. destellodilp36wled857spmmawh, crompton cat part no. lclp54 36 cdlor equivalent make in bajaj 43 supply and fixing in replacement post top lantern led type60 / 70 watt including fixing arrangments on 76 mm dia gipipe on main gate pillers 230 watt volts ac outdoor type with decorative post top for 360 degree indirect light ip 65 protection with impact and corrosion resistant complete with driver and lamp complete.complete all as specified and directed by engineer in charge. ( make : havells cat part no. coralmaxipt70wled830psymtopc, crompton cat part no. lpto 60 cdl m or equivalent make in philips ) 44 s&f led lamp 9w, white / red / yellow / blue / green color for angle holder complete all as specified and directed by engineer in charge. 45 s & f in replacement of sub main wiring with two single core cables pvc insulated and un sheathed 6 sqmm ( nominal area ) frlsh stranded copper conductor drawn inexistingpvc conduitincluding 6.00 sq mm ( nominal area ) copper cableas earthcontinuity conductor including necessary connections, pvcflexible pipes are used in pannel board while connecting the cablecomplete all as specified and directed by engineer in charge. ( note : pvc cable and pvc conduit shall be isi marked ) 46 s & f in replacement of sub main wiring with two single core cables pvc insulated and un sheathed 4 sqmm ( nominal area ) frlsh stranded copper conductor drawn inexistingpvc conduitincluding 4.00 sq mm ( nominal area ) copper cableas earthcontinuity conductor including necessary connections, pvcflexible pipes are used in pannel board while connecting the cablecomplete all as specified and directed by engineer in charge. ( note : pvc cable and pvc conduit shall be isi marked ) 47 s & f in replacement sheet metal enclosure for double door db made out of crca mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted sp & n 8 ways, 240 volts, isi marked 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation mcbs and isolators etc complete all as specified and directed by engineer in charge. 48 s & f in replacement sheet metal enclosure for double door db made out of crca mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted sp & n 12 ways, 240 volts, isi marked 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation mcbs and isolators etc complete all as specified and directed by engineer in charge. 49 s & f in replacement mcb ‘b’ series type suitable for 240 volts, ac supply5 to 40 amps, s p & n with over load and short circuit protection and rupturing capacity not less than 10ka complete all as specified and directed by engineer in charge. 50 s & f in replacementmcb ‘b’ series type suitable for 240 volts, ac supply5 to 40 amps , single pole with over load and short circuit protection and rupturing capacity not less than 10ka complete all as specified and directed by engineer in charge. 51 s&f in replacement sheet metal enclouser for doble door vertical dbs made out of crca mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mouting vtpn 4 way 415 voltisi marked 250amps busbar stove enameled dust and vermin proof, ip:43 protection suitable for incorporation fp mccb ( v tech ) n1 frame upto 125a, isolators and including give connection with wire and cable etc complete all as specified and directedby engineer in charge 52 s&f in replacement mccb 4 pole63 amps with breaking capcity 16ka , fixed tm and 415 volts ac supply isi marked complete all as specified and directed by engineer in charge. 53 s&f in replacement mccb 4 pole 40 amps with breaking capcity 16ka , fixed tm and 415 volts ac supply isi marked complete all as specified and directed by engineer in charge. 54 s&f in replacement mccb 4 pole 100 amps with breaking capcity 16ka , fixed tm and 415 volts ac supply isi marked complete all as specified and directed by engineer in charge. 55 m & l for earthing complete with gi earth plate electrode 60 cm x 60 cm x 6 mmthick burried directly in ground ( earth pit not less than 2.25 mtr deep below ground level ) with top edge of plate not less than 1.5 mtr below ground level , connecting to gi earth lead 4 mm dia gi earth wire , by means of bolts, nuts and washers of giand protection by provisionof gi medium grade pipe 15 mm bore including provision of concrete pit in pcc ( 1:2:4 ) type b1 using 20 mm grade stone aggregate with 40 mm thick cover of rcc ( 1:2:4 ) reinforced with xpm ( weight not less than 4 gs / sqmm ) and frame of angle iron 25mmx25mmx6mm with lugs 02 nos and with 6 mm dia ms bar handle made to shape , gi light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed ontop edge of earth plate common salt and charcoal filling test point made out of 40 mmx 8 mm fi with fixing arrangement , funnel, wire mesh and earth work inhard dense soil , returning filling in and removal of surplus soil to a distance not exceeding50 mtrs all as per electric plate no.3 of ssr part 1 and connecting to earth test point including taking out unserviceable earthing with all acessories all as specified or indicated including testing on complete all as specified and directed by engr in charge 56 excavation in trenches not exceeding 1.5 mtr wide and not ecxceedinf 1.5 mtr depth for laying of cablescomplete all as direted by engr in charge 57 returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm complete all as direted by engr in charge 58 removal of excavated material n exceeding 50 mtr and depositing where complete all as direted by engr in charge 59 supply and filling in sand for cable protection complete all as direted by engr in charge 60 supplying and laying un reinforced precast concrete cable cover, class lv, type 1 flat, size 250x 150mm x 40mm complete all as direted by engr in charge 61 s & f 1100 volts grade heavy duty cable pvc insulated aluminium conductor, served with inner sheathing of pvc tape and overall pvc sheathed in service connection suspended by insulating hanger not more than 1 meter apart including 4 mm suspension wire, one twin core cable flat or circular 4 sqmm, complete all as specified and directed by engineer in charge. 62 supply and lay in replacement jointing and testing and commissioning in replacement of 10 sqmm x2core xlpe insulated, screened , pvc bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & pvc sheathed lt cable 1100 v grade conforming to is 7098 laid in trenches / ducts / fixed on poles wall / laid under roads / paths / drain / culverts or passing through pipes complete all as specified and directed by engineer in charge. 63 supply and lay in replacement jointing and testing and commissioning in replacement of 25 sqmm x4 core xlpe insulated, screened , pvc bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & pvc sheathed lt cable 1100 v grade conforming to is 7098 laid in trenches / ducts / fixed on poles wall / laid under roads / paths / drain / culverts or passing through pipes complete all as specified and directed by engineer in charge. 64 m & l for air termination, single pointed, aluminium rod 12 mm dia and 300 mm long complete all as specified and directed by engineer in charge. 65 m & l for providing test point terminal block, made out of gun metal or phosphors bronze, of size 75 mm x 75 mm x 25 mm drilled and screwed including 03 nos 8 mm dia, 25 mm long hexagonal head screws complete all as specified and directed by engineer in charge. 66 m & l for aluminium strip 25 mm x 3.15 mm with saddles and fixing screws etc as in roof conductors and down conductor above ground complete all as specified and directed by engineer in charge. 67 m & l for gi strip 32 mm x 6 mm buried in ground complete all as specified and directed by engineer in charge. 68 m & l for earthing complete with gi earth plate electrode 60 cm x 60 cm x 6 mmthick burried directly in ground ( earth pit not less than 2.25 mtr deep below ground level ) with top edge of plate not less than 1.5 mtr below ground level , connecting to gi strip 32 x 6 mm as earthing lead , by means of bolts, nuts and washers of giand protection by provisionof gi medium grade pipe 50 mm bore including provision of concrete pit in pcc ( 1:2:4 ) type b1 using 20 mm grade stone aggregate with 40 mm thick cover of rcc ( 1:2:4 ) reinforced with xpm ( weight not less than 4 gs / sqmm ) and frame of angle iron 25mmx25mmx6mm with lugs 02 nos and with 6 mm dia ms bar handle made to shape , gi light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed ontop edge of earth plate common salt and charcoal filling test point made out of 40 mmx 8 mm fi with fixing arrangement , funnel, wire mesh and earth work inhard dense soil , returning filling in and removal of surplus soil to a distance not exceeding50 mtrs all as per electric plate no.3 of ssr part 1 and connecting to earth test point including taking out unserviceable earthing with all acessories all as specified or indicated including testing on complete all as specified and directed by engr in charge 69 m & l for gi water tubing, light grade, 50 mm, 1.2 m long duly threaded on one side in and including fixing of gi socket for fixing of air termination and including fi clamp of 50 x 6 mm bend to shape for fixing of gi pipe post and fixed to wall ( gi pipe 1.2 m will be in single length and no joint will be allowed ) complete all as specified and directed by engr in charge 70 supply only 16 amp 3 pintop plug 240 volt, non flamablecomplete all as direted by engr in charge. havells ahlgxxw163 pk1 71 supply only 6 amp 3 pintop plug 240 volt, non flamablecomplete all as direted by engr in charge. havells 72 s&f exhaust fan made of sturdy engineering plastic of 250mmsweep , 240 volt, complete with louvers and shutter and mounted in suitable opening arrangement in wall and connecting up including 3 core pvc insulated pvcsheathed copper conductorflexible cable 24 / 0.2mm from ceiling rose to fan complete including breaking of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to distubed wall in cement mortar ( 1 :4 ) white washing matching with existing colour etc. complete all as direted by engr in charge. 73 s&fmetal body exhaust fan 300 mmsweep, 900rpm, 230 volt, complete with louvers and shutter and mounted in suitable opening arrangement in wall and connecting up including 3 core pvc insulated pvcsheathed copper conductorflexible cable 24 / 0.2mm from ceiling rose to fan complete including breaking of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to distubed wall in cement mortar ( 1 :4 ) white washing matching with existing colour etc. complete all as direted by engr in charge. 74 note : ( i ) amount ofcreditfor retrieved materials is mentionedin sch a section ii of tender documents in pdf form which will be deducted while acceptance of tender offline. ( ii ) contractor will furnish the performance warranty certificate along with name of dealer from the manufacturer for a specified period as recmmended by the companyfor the equipments mentioned againstrespective items. ( iii ) all led lights should be marked with ge sgnr and date of fixing. ( iv ) the contracotr will liable for penalty of rs 500 / day if he fail to interain the complaint given to him on next day...

Department Of Local Bodies - Rajasthan

35936752 tender for installation work of pole and cable. providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed unarmoured / armoured aluminium cable of 1.1 kv grade as per pwd specification for electrical works in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points ( a ) , ( b ) , ( c ) , mentioned below: ( a ) material : h4 grade aluminium conductor of purity >99.6 % & as per is:1554 p i / is :7098 p – i ( b ) conductor shall have electrolytic aluminium confirming to is 8130, is 3975 1999 for armouring of cables in armoured cable items , is 5831 for sheath, is 10810 ( part 0 to 64 ) for testing procedures. ( c ) oem must have iso 9001 & 14001 certifications for qualityassuarance & its own in house nabl lab setup for all testingfacilities for cables . appropriate type test certificate / oem test report shall be submitted . all above as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr.armoured cable10.0 sq.mm 4 core 2 supply & laying following size b class , medium class g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor / strip / cable in ground / surface / recess as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr50 mm dia. 3 providing & laying of double wall corrugated pipe confirming to is : 14930 p 1 & 2 with hdpe coupler at 1 mtr. depth below the ground for laying cable including making the trench and back filling , compaction of earth as required ( excavation of earth to be paidextra as required. ) of following outer dia. / inner dia as per is:4984:1995. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexurea attached with this bsr .55 / 50 mm 4 supplying and making one end termination with heavy duty brass compression gland ( as per is 12943 1990 ) sibg type, heavy duty aluminium lugs ( as per is 8309 1993 & is 8337 1976 ) duly crimped with crimping tool, pvc tape as per pwd specification for electrical works etc for following size of armoured pvc insulated & pvcsheathed / xlpe aluminium conductor cable of 1100 volt grade as required of size. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexurea attached with this bsr . 4 x 10.0 sq.mm 5 earth work in excavation for roadway, including trimming bottom and side slopes in accordance with requirement of line, grades and cross sections, including disposal of surplus material with all lift and lead upto 1000 metre as per mort&h specification clause 301. in ordinary rock 6 supply & laying following size earth wire in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection with gi / cu thimble etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr .8 swg g.i. ( hot dipped ) wire 7 supply and erection of m.s. galvanized octagonal pole ( as per bsen 40 3 3:2003 / bsen 10025 / is 2062 is:875 part 1 – 2015 / for ms plate for base flange ) of following length and dimension as per table p 01 with base plate on the cement concrete foundation of m 20 grade ( 1:1.5:3 ) as per is 456 / is 2911. with the help of anchor bolts of grade 6.8 ( is: 1367 p iii ) . the pole shall have aweatherproof flush door and locking arrangements. complete in all respect. all as per pre approved by engineer in charge. foradditional technical parameters of products / work , refer annexure a attached with this bsr .octagonal ms poles made of s 355jo grade steel sheet , folded lengthwise to obtained octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with is 2629. ( see table p 01 for specs. ) 8 mtr. 8 9 mtr. 9 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works withisi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wireshould be made from 99.99% purity copper, class 5 stranding inacc. to iec 60228 for lower watt loss , oxygen free ( <10 ppm ) forless chances of oxidization and higher silver content for gives betterconductivity , insulation pvc type a or c , flame retardant as per is 10810 53, better amperage rating as per vde 0298 part 4, , inexisting surface or recessed pvc / ms conduit / casing cappingincluding all as per pre approved by engineer in charge, makingconnections, etc. as required. oem must have its own in housenabl lab setup for all testing facilities for wires. for additionaltechnical parameters of products / work , refer annexure aattached with this bsr .2 x 1.5 sq.mm 10 providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering all work upto plinth level : 1:5:10 ( 1 cement : 5 fine / coarse sand : 10 graded stone aggregate 40 mm nominal size ) 11 providing & fixing of 240 / 415 v ac mcb with positive isolation of breaking capacity not less than 10 ka ( b / c tripping characteristic as per type of load and site requirement ) 4kv impulse withstandvoltage, as per pwd specification for electrical works with isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec60947 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , ip 20 contact protection and fitted with existing distribution board / sheets, min. operation 20, 000 upto 32 a rating and 10, 000 upto 63 a, 5000 for 80 a rating including making connections, testing etc. as required. . oem shall have submit nabl / cpri / erda accrediated lab test reports before execution & all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr .single pole mcb6 a to 32 a rating 12 supply and fixing on existing poles single arm overhang decorative sword type m.s.pipe bracket incliding 48.3 o.d.pipe 3.25mm thick decorative frp knob and frp dome as per enclosed drawing complete work.as per requirsd8 or 9 mtr.gi octagonal. 13 supply and fixing on existing polesdoublearm overhang decorative sword type m.s.pipe bracket incliding 48.3 o.d.pipe 3.25mm thick decorative frp knob and frp dome as per enclosed drawing complete work.as per requirsd8 or 9 mtr.gi octagonal....

Military Engineer Services - Rajasthan

35867627 provision of external service for five ifs sites at af stn jaisalmer surface excavation not exc. 30cm deep & averaging 15 cm deep in soft / loose soil and getting out complete all as specified and as directed . 2 excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed 3 returning, filling in approved soft / loose soilincluding spreading, leveling, watering and well ramming in layers each n.exc 25cm complete all as specified and as directed . 4 removing surplus soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed . 5 labour only ( except material for road side berms of 100 mm spread thickness with available approved soil / moorum obtained from within md land as directed spread rolled and consolidated to gradient and camber required etc complete all as specified and as directed by engineer in charge.note 1.approved soil / moorumshall be obtained from within md land as directed 2. no lead charge or charge of whatsoever nature shall be paid on this account. 6 factory made kerb stone of m25 grade cement concrete in postion to the required level and curvature , jointed with cement mortar 1:3 including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm ) including making drainage opening wherever requiredincluding demolition of existing kerb stone complete all as specified and directed. 7 preparation of newly surface of road side kerb stone and applying two coats of synthethic enamel paint of approved different tint and pattern over a coat of primer etc complete all as specified and directed. 8 hardcore of broken stone or boulders of gauge not exceeding 63 mm, deposited, spread and leveled in layers not exceeding 15 cm thick, watered and rolled to a true surfacecomplete all as specified and as directed . 9 75 mm thick pcc ( 1:4:8 ) type d 2 using 40mm graded stone aggregate as in sub base including finishing the top surface of concrete even and roughcomplete all as specified and as directed . 10 60mm thick m 35 grade machine pressed with grey cement and no pigment interlocking factory made paver blocks of any size and shape conforming to is 15658 2006, set, jointed and pointed in dry sandover and including 25 mm thick sand cushion complete all as specified and as directed . 11 excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in hard / densesoil complete all as specified and as directed 12 galvanized steel water tubing medium grade isi marked of 100mm bore with & including all necessary fittings complete, laid in trenches, complete all as specified and directed.note : excavation & earthwork shall be measured & paid for separately under relevant items of this schedule. 13 galvanized steel water tubing medium grade si marked of 40mm bore with & including all necessary fittings complete, laid in trenches, complete all as specified and directed.note : excavation & earthwork shall be measured & paid for separately under relevant items of this schedule. 14 galvanized steel water tubing medium grade si marked of 25 mm bore with & including all necessary fittings complete, laid in trenches, complete all as specified and directed.note : excavation & earthwork shall be measured & paid for separately under relevant items of this schedule. 15 cast iron body sluice valve heavy duty class ‘pn 1.6’, 100mm bore, isi marked with confirming to is 14846 2000, both flanged ends and drilled, high tensile stainless steel spindle, cast iron gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts ( high tensile ) , washers etc, and testing, includingtaking out old unserviceable sluice valve of 100mm bore, complete all as specified anddirected. 16 gun metal globe or gate valve, with iron wheel head, screwed both ends, isi marked for 40mm bore pipe linecomplete all as specified and directed. 17 gun metal globe or gate valve, with iron wheel head, screwed both ends, isi marked for 25mm bore pipe linecomplete all as specified and directed. 18 cutting existing steel tubing for alteration or addition ( each cut measured ) complete all as specified and directed. 19 screwing existing steel tubing foralteration or addition ( or lengthening screw on pipe to from connector ) complete all as specified and directed. 20 construction of stone masonary valves pit of size 900mmx 900mm x 900mm ( internal dimention of chamber ) made with bulit in cement mortar 1.6 for sluice valve chamber including necessary excavation, foundation concrete in pcc 1:4:8 type d2 using 40mm graded stone aggregate for foundation and 15mm thick inside cement plaster with cement mortar 1:4 with floating coat of near cement, pcc coping type b1 ( 1:2:4 ) using 20mm graded stone aggregate including necessary form work with ms frame with angle iron 50x50x6 mm and cover of ms sheet 3.15mm thick including tarring and painting ( where required ) the steel surface with two coats of synthetic enamel paint over a coat of red oxide prime complete as specified and locking arrangement directed. 21 cutting existing pipe of any type and size and tapping of pipe line by providingof tee gi of size 100 x 100 x100 mmcomplete all as specified and directed. 22 pcc 1:2:4 type b 1 using 20mm graded stone aggregate as incopingof poles / pipe / plateform / path etc i including necessary use and waste of formworkand finishing the top surface of concrete even and smooth with using extra cement complete all as specified and as directed . 23 sand cushioning and cover ( using local tibba sand ) , 80 mm thick before laying of cable and 150 mm thick after the cable is laid, complete all as specified and as directed by engineer in charge. ( note :1. approved local tibba dry sand after removal of vegetations, grass and other deleterioussubstances shall be used for sand cushioning and cover ) . 24 jodhpur stone rough dressed slab, 40 cm to 50 cm thick, 25 cm to 35 cm wide of 80 cm long dry abuttting each other for protection to under groung cable, complete all as specified and as directed . 25 supply, laying, jointing and testing xlpeinsulated screened pvc bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade cross sectional area 35 sq mm 3.5 core confirming to is 7098 ( part i 1988 ) laid in trenches, along poles through pipes etc. complete all as specified. notes : ( i ) sand cushioning, cable protection, gi pipe and excavation & earth work shall be measured & paid for separately ( ii ) road cutting / floor cutting / cutting holes etc in walls required for laying / fixing of cable etc shall be made good as per existing. nothing extra shall be admissible on this account. quoted rates shall be inclusive of the above provisions. 26 supply, laying, jointing and testing xlpeinsulated screened pvc bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade cross sectional area 50 sq mm 3.5 core confirming to is 7098 ( part i 1988 ) laid in trenches, along poles through pipes etc. complete all as specified. notes : ( i ) sand cushioning, cable protection, gi pipe and excavation & earth work shall be measured & paid for separately ( ii ) road cutting / floor cutting / cutting holes etc in walls required for laying / fixing of cable etc shall be made good as per existing. nothing extra shall be admissible on this account. quoted rates shall be inclusive of the above provisions. 27 supply, laying, jointing and testing xlpeinsulated screened pvc bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade cross sectional area 185 sq mm 3.5 core confirming to is 7098 ( part i 1988 ) laid in trenches, along poles through pipes etc. complete all as specified. notes : ( i ) sand cushioning, cable protection, gi pipe and excavation & earth work shall be measured & paid for separately ( ii ) road cutting / floor cutting / cutting holes etc in walls required for laying / fixing of cable etc shall be made good as per existing. nothing extra shall be admissible on this account. quoted rates shall be inclusive of the above provisions. 28 40 mm bore gi tube, light grade galvanised with clamp of 25 x3 flat ironfor protection of cable , with all fitting leadin trenches / under road / with wall / in wall / pole / under floorwhere requiredcomplete all as specified and as directed 29 80 mm bore gi tube, light grade galvanised with clamp of 25 x3 flat ironfor protection of cable , with all fitting leadin trenches / under road / with wall / in wall / pole / under floorwhere requiredcomplete all as specified and as directed 30 drilling ( horizontally ) of holes under road 110 mm dia , pavement , hard standing by trench less technology ( manually ) with out disturbing the top surface of road ( maxium 10 mtr wide ) for laying of cable / gi pipescomplete all as specified and as directed . 31 earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground ( earth pit not less than 2.25m deep below ground level ) with top edge of plate not less than 1.5 deep below normal ground level and connected to and including galvanized earth lead wire 4mm dia upto 7.5 metre by means of gi nuts, bolt, check nuts, washers thimbles, etc as shown in electrical plate no 03 ssr part i and connection to main switch board or panel and testing on completion including excavation and earth work in any type to soil, returning fitting in and removal of surface spoil to a distance not exc 50 metre, pcc chamber ( 1:3:6 ) type c 2, charcoal and salt mixed layer 15cm thick all around the earth plate electrode, ms funnel with wire mesh, gi pipe light grade 20mm bore for watering and 15mm bore meter long gi pipe light grade for earth wire protection fixed with poles with two clamps, made from ms flat 25mm x 3mm, bolts, nuts and washers 75mm thick rcc cover 1:2:4 type b 1 shall be provided on ci frame etc complete all as specified. note pcc chamber shall be constructed at least 1.5m away from the earth electrode.the pipe for watering shall be provided in slanting manner.including the cost of 7.50m gi pipe for protection of earth wire / strip 32 earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground , ( earth pit not less than 2.25 meter deep below ground level ) with top edge of plate not less than 1.5 meter below normal ground level , connected to and including galvanised iron earth wire 32 x 6 mm by means ofnut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of mes ssr part i ( 1991 ) note: ( a ) excavation and earth work for drilling hole for electrode in any type of soil. ( b ) pcc pit in cement concrete 1:2:4 type b 1, pre cast rcc cover with suitable handle 40 mm thick in pcc 1:2:4 type b 1, reinforced with welded steel wire fabric weighing not less than1.87 kg / sq meter. ( c ) funnel with watering pipe of gi 20 mm nominal bore light grade and lugs etc complete all as specified and directed ( d ) 40 mm nominal bore medium grade gi protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. ( e ) requisite quantity of common salt and charcoal. ( f ) testing of earthing. 33 sub main wiring with 2 run of single core 6.0 sqmm multi stranded copper conductor 1100 volts grade frls pvc insulated unsheathed cable drawn through and including pvc conduit of suitable size onwall isurface ncluding 4.0 sqmm pvc insulated unsheathed single core copper conductor earth wireincluding taking down old unserviceable submain wiring complete all as specified. note : two run of 6.00 sqmm cable and one run of 4.00 sqmm cable as earth wire continuity conductor and stove enamelled steel conduit shall be measured & paid as one unit. 34 sub main wiring with 4 run of single core 6.0 sqmm multi stranded copper conductor 1100 volts grade frls pvc insulated unsheathed cable drawn through and including pvc conduit of suitable size on wall surface includingtwo run of 4.0 sqmm pvc insulated unsheathed single core copper conductor earth wire in and including taking down old unserviceable submain wiring complete all as specified. note : four runs of 6.00 sqmm cable and two run of 4.00 sqmm cable as earth wire continuity conductor and stove enamelled steel conduit shall be measured & paid as one unit. 35 sheet metal enclosureflush mounting factory made for tpn db 4 way, 415 volt, ac 50 hz double door, ip 43 protection, ik 09 built in bus bar completewith siitable for incomming mcb and outgoing mcbs and fixed in recess on wallcomplete all as specified and as directed . 36 mcb, tpn, 5 to 32 amps rating, with over load and short circuit protection c curve and rupturing capacity 10 ka, 240 volt grade, ac supply, 50 hz and making connections using suitable size copper lugs / thimbles including complete, all as specified & directed. 37 mcb, single pole, 5 to 32 amps rating, with over load and short circuit protection c curve and rupturing capacity 10 ka, 240 volt grade, ac supply, 50 hz and making connections using suitable size copper lugs / thimbles including complete, all as specified & directed. 38 supply and fix cable jointing kit for 1.1 kv grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3 ½ / 4 core xlpe, armoured, aluminium conductor cable of size 185sqmm complete all as specified and directed. 39 mcb, single pole, 40 to 63 amps rating, with over load and short circuit protection c curve and rupturing capacity 10 ka, 240 volt grade, ac supply, 50 hz and making connections using suitable size copper lugs / thimbles including complete, all as specified & directed. 40 design, supply, erection, commissioning and testing of outdoor type lt feeder pillar box, double door, suitable for 3 phase 4 wire, 415 volts ac supply and having 4 nos copper bus bar not less 150 amps for distribution system and type tested at cpri, fabricated in factory having modern fabrication and testing facility which includes seven ( 07 ) tanks pre treatment facility comprising of de greasing, rinsing, de rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting ( thickness not less than 80 micron ) with approved shade of ral 7032.the feeder pillar shall be provided with suitable neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than ip 55 and general construction conforming to is : 13947. the feeder pillar shall be made out of 3.15mm thick crca mild steel sheetand 3.15mm thick gland plate duly compartmentalized for each control gear and bus bar, front door ( 02 layer ) and rear door ( 01 layer ) opening facility and 4 side slanting canopy type roof on top and mild steel channel ( 75 mc ) base frame at bottom and having welded equal angle of 75mmx75mmx6mm of length 0.9mtr, 04 nos, 30cm ofangle shall be embedded in pcc 1:2:4, 20mm graded stone agregate below gl level and 30cm shall be above ground level of size as directed by engr in charge at site. the feeder pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation.necessary cable gland shall be provided for all incoming and outgoing cables. 41 control wiring : all control wirings shall have to be carried out with 1100 volts rated frls grade pvc insulated multi stranded type copper wire of cross sectional area 1.50sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with pvc spring type tube near the door hinges.cable alley : necessary cable alley shall be provided for out going cables in both sides of lt panel with terminal block, the terminal block shall be connected with the outgoing mccb with copper bus bar of suitable size incoming : mccb 100 amps, 4 pole , thermal magneticrelease, 16 ka, adjustable, 70% to 100% 1 nos outgoings : ( a ) mccb 63 amps, 4 pole , thermal magneticrelease, 16 ka, adjustable 70% to 100 % 2 nos ( b ) mccb 40 amps, 4 pole , thermal magneticrelease, 16 ka, adjustable 70% to 100% 1 nos ( c ) bakelite fuse holder with 5 amps hrc type control fuse 03 nos. ( d ) led pilot lamp suitable for 230 volts ac supply with integral circuit and cluster led of following colours : ( i ) red 01 no, ( ii ) yellow 01 no, ( iii ) blue 01 no. ( e ) digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% 01 nos ( f ) digital ammeter 96mm x 96mm suitable to read 0 to 100amps, accuracy class 1% 01 nos ( g ) current transformer ( ct ) of rating 100 / 5, tape wound, rated burden 5 va 03 nos ( h ) led indicator lamps complete with integral circuit and cluster led, suitable to operate in 230 240 volts ac supply 1set of 03 nos ( red 01, yellow 01, blue 01 ) ( j ) 02 nos.danger notice plate duly written in signal red colour on aluminium plate in english and hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber. ( note : 1. the feeder pillarbox shall be designed in such a way that adequate workable space is made available inside the compartments and the front area of the panel shall not be less than 1.00 sqm and 500mm depth ) .2. the contractor shall submit lt panel / feeder pillar boxdrawings to the engr in charge for approval before procurement of material. 42 plain cement concrete ( 1:2:4 ) type b 1 ( using 20mm graded stone aggregate ) in lintel, cill, bed block coping , bed plate, bond stone etc including weathering slightly rounded or chamfered angles and throating and necessary form workcomplete all as specified and as directed ....

Military Engineer Services - Rajasthan

35865736 tender for repair and maintenance of misc b / r and e / m nature work in area under age ( i ) pokaran taking down carefully by unscrewing from boards / outlet boxes, switches, bell push, socket outlets, fan regulators, buzzers, holder and taken as schedule of credit. 2 disconnecting and removingthe mcbs, mccbs, dbs, metal clad switch from any height , stripping out the fitting for examine replacement of unserviceable spare parts, reassembling, refixing in original position includingminor repairs for the smooth functioning and testing complete all as specified & directed by engg in charge 3 m&l for attending, repair and rectification ofany type of internal elect supply complaint viz light point / fan point / 5 / 15 amps switch socket / submain wiring / mcbs / dbs / no electric supply on 230v / 415v system along with necessary t&p, safety devices, without replacement of items as per site requirement and as directed by engr in charge.note :1.the contractor shall detail / depute his supvr / electrician to receive the complaints from the concerned complaint cell and rectify the same on the given day alongwith necessary manpower and t & p as required.after completion of the complaints attended, the docket / slips shall be handed over to the concerned complaint cell.2. the cost of the stationery such as complaint register and docket book shall be deemed to be included in the rate quoted. 4 s & fswitch piano single pole flush type 5 amps, 230 volts. 5 s & fswitch piano single pole flush type 15 amps, 230 volts. 6 s & f single pole modular switch 1 way 6 amps, 1 module 7 s & fsingle pole modular switch 1 way 16 amps, 1 module 8 s&fbell push 5 a flush type 9 s&f modular bell push 6a, 1 module 10 supply and fixsocket outlet modular type multipurpose 2 / 3 pin, 6 amps, 230 volts combined 2 module 11 supply and fixsocket outlet modular type multipurpose 3 / 5 pin, 6 / 16 amps, 230 volts combined 2 module 12 supply and fixsocket outlet flush type multipurpose 2 in 1, 3 pin, 5 amps, 230 volts all as specified 13 supply and fixsocket outlet flush type multipurpose 2 in 1, 3 pin, 5 / 15 amps, 230 volts all as specified 14 s & fswitch socket combination flush type multipurpose 2 / 3 pin 5 amps 2 in 1230 volts all as specified. 15 s & fswitch socket combination 5 in 1 multipurpose 3 / 5 pin 5 / 15 amps flush typewith complete all as specified. 16 s & fmodular ceiling fan regulator stepped socket size ( modular ) suitable to work on 230 volts complete all as specified, 2 module 17 s & felectronic type regulator single module stepped heavy duty for ceiling fan suitable to work on 230 volts complete all as specified. 18 s & f electronic type regulator two module stepped heavy duty for ceiling fan suitable to work on 230 volts complete all as specified. 19 s&fbell ( buzzer / ding dong ) working on 230 volts ac supply 20 s & f lamp holder insulated body surface bakelite with back plate suitable for angle / batten fittings 21 s & fwall mounted 2 ft led batten of 9 watt with led lamp, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver complete including taking down all as specified and directed by engg in charge. make : havells cat part no luminebs9wled865spcwh / bajaj cat part no. bclsb10nw or equivalent. 22 s & f 4 ft box type tube light fitting with led tube rod of 18 / 22 watt , extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver complete including taking down all as specified and directed by engg in charge . make : havellscat part no regalbatten8upto1x22wssbswh and crystal1213t8dstl20wled865sglass / luker cat part no.llts1 or equivalent 23 supply and fix 4ft led tube rods of 18 / 20 / 22 watt complete including taking down all as specified and directed by engg in charge make: havells cat part no. crystal1213t8dstl20wled865sglass / bajaj cat part no.18wcdl orequivalent 24 s & f security lights of 1x25 watt led light with high power led and unique peanut lens to ensure uniform distribution and including provision of 1.5 sqmm 3 core multistranded copper conductor cable from light fitting to junction box complete all including taking down as specified and directed by engg in charge.make : havells cat part no endura pearl sl25wled757sasytopcmp / luker cat part no lst24 or equivalent 25 m & l bracket made out of gi pipe of suitable dia not less than 1.2 mtr long and fixed on walls with 2 nos ms clamps made out of ms flat of suitable size thick complete with ms nuts, bolts and washers etc bent to required shape complete including taking down all as specified and directed by engr in charge 26 s & f 15 watt recess mounted circular downlight with white powder coated polycarbonate housing and pressure diacast , heat sink having high efficiency and including taking down all as specified and directed by engr in charge make : havells cat part no enduraneodlr15wled840mod and analogdrivernm12 / 15w / crompton cat part no.scr 15w cdl orequivalent 27 s & f 15 watt surface mounted circular downlight with white powder coated polycarbonate housing and pressure diacast , heat sink having high efficiency and all including taking down as specified and directed by engr in charge. make : havells cat part no enduraneohesurfacedls15wled840s / crompton cat part no. lcdspln r 12 ww or equivalent 28 s & f 24 watt recess softline luminaire ( 1x1 ) suitable for armstrong / grid ceiling with high brightnesswhite leds and pmma extruded diffuser giving glare free light and good aesthetic appeal and all including taking down as directed by engg in charge. make : havells cat part no pluto 1x1 plr15wled857s / crompton cat part no. ccr 141 24 57 sl nwh or equivalent 29 all as per sl item no 49. here in before, but 2x2 fittings of 45 wattsincluding taking down all as specified and directed by engr in charge. make : havells cat part no venus neo he 2x2plr42wled857mod , leddriver63v1a42ws / crompton cat part no.ccr 126 50 40 sl nwh or equivalent 30 s & f 10 watt bulk head luminaire suitable for outdoor with high brightness giving glare free light and including taking down all as directed by engg in charge. make :havels cat part no. hexaft10wled857ssymbopc / bajaj bibwp10wled or equivalent 31 s & f mcb sp 6 to 32 amps 240 volts for fixing on mcb dbsall as specified. 32 s & f mcb sp40 to 63 amps 240 volts for fixing on mcb dbsall as specified 33 s & f mcb spn 16 to 32 amps 240 volts for fixing on mcb dbsall as specified 34 s & f mcb spn 40 to 63 amps 240 volts for fixing on mcb dbsall as specified 35 mcb four pole, 415 volts suitable for fixing in mcb db of capacity63 amps including removing the existing us one and making good the distrubed surface to match with the existing surface. 36 mcb four pole, 415 volts suitable for fixing in mcb db of capacity100 amps including removing the existing us one and making good the distrubed surface to match with the existing surface. 37 s & f sheet metal enclosure mcb dbspn 4 way with 200 amps rated bus bar 240 volts double door with locking system complete all as specified 38 all as per sl item no 37 here in before, but spn 8 way db 39 all as per sl item no 37 here in before but spn 12 way db 40 s & f horizontal type tpn db 4 way double door made out of crca sheet housing duly powder coated & confirming to is specification complete all as directed by engr in charge. 41 s & f vertical loadline type tpn db 4 way double door with incoming as mccb tp 415 volts ac 3 phase50 hz with fixed magnetic setting for current rating of 100 amps 16 ka ( mccb tp confirming to is specification made out of crca sheet housing duly powder coated & confirming to is specification complete all as directed by engr in charge. 42 s & f single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole mcb 20 amps ( ac box ) all as specified and directed 43 s&f mccbs 415v, 25ka, 100 amps 4 pole suitable for db including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface. 44 all as per sl item no 43 here in before, but 63 amps, 10 ka 45 m & l submain wiring with 2 runs of single core 4 sqmm pvc insulated frls multistranded 1100 volts grade wire, copper conductor drawn through and including non metalic rigid pvc conduit and conduit accessories of medium grade not not less than 25mm dia including one run of single core 4 sqmm pvc insulatedsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from db to db / main board including removing the existing unserviceable submain riwing complete all as specified and as directed. 46 all as per sl item no 45, but 2 runs of single core 6 sqmm and one run of single core 6 sqmm as earth continuty conductornote :for sl item no 66 to 67: two runs of cable, one run of earth wire and one run of pvc conduit will be measured as one unit 47 supply and fix 36 watt cfl 4 pin typecomplete all as specified and directed by engg in charge. 48 supply and fix 18 watt cfl 2 pin typecomplete all as specified and directed by engg in charge. 49 supply and replace electronic driver fordownlight of any capacity / watt as per site required all as specified and directed by engineer in charge. 50 supply and replace electronic driver for led light of2x2 fittingof any capacity / watt as per site required all as specified and directed by engineer in charge. 51 supply and replace bi pin holdersuitable for 40 / 28 watts tubes ( pin & screw type ) 52 supply and replace cfl holdersuitable for 2 / 4 pin for 9 to 36 watts 40 / 28 watts tubes ( pin & screw type ) 53 supply and replace fan condenser 2.5 mfd 54 supply and replace fan condenser of 4.00 mfd 55 supply and replace split pins / lock pins for ceiling fans 56 supply and replace ms clamp with rubber bushes, bolts & nuts for ceiling fan along with lock pin all as specified 57 m & l for repairs to copper inner container like denting, soldering, brazing, leak testing and reassembling of any ltrs capacity water heater ( geyser ) complete all as specified. 58 supply and replace geyser element2000 watts of any type or as per site requirement 59 supply and replace thermostat 60 supply and replace indicator bulb 230 v suitable for any make and colour. 61 supply and replace pvc cold / hot water connection pipe 45 cms long 15 mm dia 62 m & l rewinding of burnt ceiling fan of1200 / 1400mm sweep motor with supper enameled copper wire of suitable size including repainting it white , replacement of sealed bearing and shaft of any make, type, model incl transportationcomplete all as specified and directed by engineer in charge. 63 m & l rewinding of burnt exhaust fan of 225 / 300mm sweep motor with supper enameled copper wire of suitable size including repaintingas per site requirement, replacement of sealed bearing and shaft of any make, type, model incl transportationcomplete all as specified and directed by engineer in charge. 64 s&f ceiling fan downrod of required heightincluding drilling of holes and threads for the same as per the site requirement all as direted by engineer in charge. 65 s & f ceiling rose three terminal surface bakelite type ac 50 hz 230 volts of size 65 x 50 mm complete all as specified. 66 supply and replace pvc round blocks 67 supply and replace pvc dummy sheets circular type of 4 68 supply and replace pvc dummy sheets circular type of 6 69 supply and replace rigid pvc casing & capping 20 / 25 mm wide 70 supply and replace pvc rectangular box ( gang box ) with 5 amps switch socket 71 supply and replace pvc rectangular box ( gang box ) with 5 / 15 amps switch socket 72 supply and replace pvc wire of flexible cord with copper conductor multistanded of twin core 23 / 0.198sqmm 73 supply and replace pvc insulated frls copper wire of size 1.5 sq mm multistranded 1100 volts grade 74 supply and replace pvc insulated frls copper wire of size 2.5 sq mm multistranded 1100 volts grade 75 supply and replace pvc insulated frls copper wire of size 4.0 sq mm multistranded 1100 volts grade 76 supply and replace pvc insulated frls copper wire of size 6.0 sq mm multistranded 1100 volts grade 77 supply and replace service wire twin core of 10.0 sq mm multistranded 1100 grade 78 supply and replace plug top 5 amps 3 pin 250 volts 79 supply and replace plug top 15 amps 3 pin 250 volts 80 supply and fix white hylam plain laminate sheet ofthickness as per the site requirement and as directed by engr in charge. 81 repair / maintenance of 25 ltrs ro plant of any make by removing of all electrical connections and water connections, rectification of all electric complaints including replacement of wiring and cleaning of all filters all as specified by engr in charge 82 s&f filters of 25 ltrs ro plant all as specified and directed 83 taking down chowkats or frames with shutters ( w / o taking of shutters from the frame ) exc. 1.5 sqm but n.exc. 4 sqm & removing from site. 84 taking down chowkats or frames with shutters ( w / o taking of shutters from the frame ) area n. exc 1.5 sqm removing from site 85 taking down shutter of any description and removing frome siteexc. 1 sqm & n. exc. 2 sqm each leaf. 86 taking down shutter of any description and removing frome siten exc. 1 sqmeach leaf. 87 m&l for joist, channel, angle, or tee sections, fixed independently, without connection plate, etc. ( cut to ordinary lengths i.e. within 20mm of the length indicated ) fe 410 w ( gde e 250 ) quality a 88 s&f 35mm thick plain framed, panelled shutter ( two panel ) with lock rail and panel of 9 mm b.w.p commercial ply or 12 mm veneered particle board with commercial veneering on both faces. the size of rail and stile as per is: 1003 ( part i ) , kiln seasoned and chemically pressure treated 89 supply and fix flush shutter solid core construction with block board core and plywood face panels commercial typeboth side, 30mm thick. 90 s / f 2nd class h.w. skeleton shutter 35 mm thick open rebated & prepared to receive glass, gauze, etc. divided into squares with plain chamfered or rounded & rebated sash bars ( of any nos ) as spd in ssr pt i sec 8 cl. 8.20. ( a ) . 91 s&f solid pvc door frame of size 50mm x 47mm made out of 5mm plain colour pvc sheet reinforced with m.s square tube, supplying & fixing in opening as per specification & drawing 92 s&f factory made solid panel pace door shutter 30mm thick ( style ) consisting of frame made out of m.s. tubes for top & bottom rails, m.s. frame shall be covered with heat moulded plain colour pvc `c channel heaving a pvc sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour pvc sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour pvc sheet to be fitted in the m.s frame wedded / sealed to the stiles, & rails with suitable pvc sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing. 93 steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded 94 steel ventilator with top hung shutter including hinges, steel peg stay, complete 95 s&f 4 mm thick sheetglass ordinary quality and glazingwith oilputty in squaren exc 0.50 sqn in each pane. 96 s&f 4 mm thick figured glass, pin headed type and glazingwith oilputty in squaren exc 0.50 sqn in each pane. 97 resecuring or easing & adjusting, taking down shutters of any description n exc 1 sqm each refixing in same opening 98 resecuring or easing & adjusting, taking down shutters of any description exc 1 sqmn exc 2 sqm each, refixing in same opening 99 s&f 100 mm long mild steel but hinges medium weight cold rolled. 100 s&f in repairs 100 mm long mild steel but hinges medium weight colld rolld. 101 s&f 150 mm long aluminium anodised barrel tower bolt of extruded section. 102 s&f in repairs150 mm long aluminium anodised barrel tower bolt of extruded section . 103 supply and fix 150mm long extruded aluminium alloy handles, 150mm long fabricated type., anodised 104 supply and fix in repairs extruded aluminium alloy handles, 150mm long fabricated type., anodised 105 s&f 300 mm long aluminium alloy anodised sliding door bolt with hasp staple ( bolt type ) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast alu allow. 106 s&f in repairs 300 mm long aluminium allow anodised sliding door bolt with hasp staple ( bolt type ) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast alu allow. 107 s&f stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples 108 supply & fix in repair stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples 109 supply and fix in repairs floor door stopper of aluminium body and tongue anodised with hard drawn steel spring fixed in floor over all length of cover plate 150mm. 110 supply and fix repairs decorative type curtain rod , stainless steel, 25 mm dia with not less than 1mm wall thickness complete all as specified and directed. 111 supply and fix decorative type brackets , stainless steel, suitable for above curtain rod complete all as specified and directed. 112 hacking out old broken glass ( any thickness, size, quality or description ) frommetal frame including punching or drilling out old glazing pins / spring clips and providing and fixing new ones 113 s&f 3 mm thick sheet glass ordinary quality & glazing with oil putty in squares n. exc. 0.5 sqm in each pane. 114 s&ffigured glass 3 mm thick, pin head type & glazing with oil putty in squares n. exc. 0.5 sqm in each pane 115 prelaminated particle board, interior grade, prelaminated both side 18 / 19 mm thick with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work but prelaminated both sides with decorative choice laminations 116 s&f continuous ( piano ) hinges, mild steel, bright finish or electro galvanizedwidth of flaps ( when open ) 30 mm. 117 m&l iind class hard wood plain fillets, square, rectangular or triangular in section, clean swan, se cured with nails or brads, sectional area not exc 3.00 sqcm. 118 s & f aluminium anodised hasp and staple 75mm , safety type, mild steel hinge pin including bolt to hinge plate and fixed with screws 119 s&f 100 mm long aluminium anodised barrel tower bolt of extruded section . 120 supply and fix extruded aluminium alloy handles, 100 mm long fabricated type., anodised 121 s&f, anodised aluminium frame & shutter for door, window and ventilator including necessary jointing cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, hinges, tower bolt, etc complete all as specified & directed by engineer in charge. 122 supply only 5.5 mm thick sheet glass, selected quality, in square exc 0.5 sqm each pane including solar control film 25 micron reflective type over it. 123 supply only 5.5 mm thick sheet glass, selected quality, in square nexc 0.5 sqm each pane including solar control film 25 micron reflective type over it. 124 s&f door closer ( aluminium extuded body section ) hydreulically regulated, , designation no 1 universal type, suitable for door shutters up to 700mm in width and of wieght not more than 35kg complete all as directed. 125 s&fmild steel 4 lever mortice lock, vertical type of size 100mm all as directed. 126 dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing ) , removing serviceable tiles to store and rubbish off the premises 127 m&l for colored non skid ceramic tiles 7 to 8 mm thick ( square / rectangular ) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or colored cement to match, including 15 mm thick screed bed or bedded layer in cement mortar 1:6 for laying floor finish. 128 m&l for colored glazed ceramic tiles ( 300mm x450mm ) x 7 mm thick on vertical surfaces set and jointed in neat cement slurry and pointed in white or colored cement to match including 10 mm thick plaster in cement mortar ( 1:4 ) on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing to receive / fixing dado / skirting tile. 129 dismantling of stone slab in any description or thickness, laid bedded jointed in any morter. 130 material and labour for granite ( of any type ) 18 to 20 mm thick work ( table rubbed and polished ) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar ( 1:4 ) including pointing in white cement ( 1:2 ) using marble dust with admixture of pigment to match withshadeincl 15mm thick screed bed in cm 1:6 complete. 131 drilling holes for bolts, pipes, etc. n. exc 25mm dia in granite or trape stonefor gas connection pipe 132 rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations 133 s&f vitreous china coloured wash hand basin 580mm x 450mmfixed in repairs including 15 mm pillar cock cast copper alloy cp, 15mm cast copper stop valve, 32 mm brass cp waste fitting & 15 mm pvc connection pipe 450 mm long fixed in repairs 134 s&f vitreous china wash down water closet coloured pan ( pedestal pattern ) , white ( excluding fixing bolt, flushing cistern and flush pipe ) complete connected to drain fixed in repair 135 supply and fix in repairs vitreous china squatting pan, ‘orissa’ pattern, size 580 x 440 mm white, with integral foot rests ( excluding flushing cistern and flush pipe ) 136 s&f in repairs plastic water closet seat cover black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminum hinging device 137 s&f pvc flushing cistern 10 ltrs capacity isi marked incl pvc down take pipe and connection etc all complete in repairs. 138 supply and fix in repairs vitreous china bowl urinal flat back, size of 465 x 355 x 265 mm white ( minimum ) , with grating and union ( exclusive of fixing supply pipe to flushing cistern, trap and waste pipe ) fixed in repair 139 s&f for stop cock copper alloy cp screwed down high pressure with crutch or butterfly handle screwed both ends for iron / pipe or for union and fixed 15 mm bore in repairs 140 s&f bib taps cast copper alloy with crutch or butterfly handle, chromium plated fancy type screwed down, screwed for iron pipe or for brass ferrule and fixed in repairs 141 s&f in repairs cp health faucet spray with 1.5m long pipe with wall hook& fixed in repair complete 142 supply and fix in repairs bib taps two way type , cast copper alloy with crutch or butterfly handle, sc rewed down, screwed for iron pipe or for brass ferrule 15 mm boreand fixed 143 s&f in repairs 32mm dia pvc waste pipeforkitchen sink , whb , urinal etc 144 supply and fix 15mm bore pillar taps of cast copper with capstan head cp screwed down high pressure with or without lettered hot and cold with long screwed shank and fly nut for iron pipe and fixed in repairs 145 s&f in repair brass cp mixer for mixing hot & cold water screwed down for iron pipe and fixed 146 s&f pvc connections 15 mm size with ptmt nuts to length 450 mm in repairs. 147 s&f , brass, chromium plated, tubular towel rail, 20mm dia, d type, 60cm long between flanges 148 s&f in repairs soap dish, any type, fixed to plugs with chromium plated brass screws 149 supply and fix in repairs brass chromium plated shower roses 125mm sizewith or without swivel joints, any size, including fixing to steel pipe or union 150 s / f s s grating dome of 100 mm dia ( min wt 25 gms ) to floor traps in repairs. 151 s & f 600mmx450mm beveled edge mirror of selected quality glass, mounted on 6mm thick ac building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers 152 taking down steel tubing and connections including cleaning for re fixing or removal to store of 15 mm bore 153 taking down steel tubing necessary fittings connection etc for 20 mm bore pipe 154 cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth 155 s&f gi tubes of medium grade with all fitting and fixed complete to walls and ceilings or laid in floors of 15 mm dia 156 s&f tubes medium grade galvanized with all fittings and fixed complete to walls and ceiling or laid in floors 20 mm dia 157 supply and fix pvc ( swr ) floor trap, plain with grating including jointing with solvent cement 75 mm dia out let 158 s&f in repair pvc ( swr ) pipes single socketed in any length with rubber ring joints fixed to walls 110 mm dia 159 s&f in repair pvc ( swr ) pipes single socketed in any length with rubber ring joints fixed to walls 75 mm dia 160 supply and fix in repairs ball valves high pressure of ptmt with epoxy coated aluminium rod and highdensity plastic ball screwed for iron pipe and fixed in repairs of pipe 15 mm dia. 161 supply and fix in repairs ball valves high pressure of ptmt with epoxy coated aluminium rod and highdensity plastic ball screwed for iron pipe and fixed in repairs of pipe 20 mm dia. 162 supply and fix in repairs 15 mm dia bib tap standard of ptmt any colour high pressure screwed for iron pipe and fixed . ( minimum weight 15mm 90gms / 20mm 125gms ) 163 supply and fix in repairs 15 mm dia pillar taps of ptmt any colour high pressure screwed for iron pipe and fixed ( minimum weight 15mm 110gms ) ) 164 supply and fix in repairs 15 mm dia stop valve of ptmt any colour high pressure screwed for iron pipe and fixed ( minimum weight 15mm 90gms / 20mm 112gms ) 165 s&f in repairs sinks made of stainless steel of 1 mm thick kitchen sink with plug washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495 x 420 mm bowl size 410 mm x 330 mmx 160 mm 166 s&f in repair sinks made of stainless steel 1mm thick in kitchen sink with plug washers and waste pipe including bedding in cement mortar to dwaft wall or incl fixing cantilever brackets and connecting unionto pipe over all size 915 x 460 mm bowl size 410mm x 330 mm x 160mm all as specified and directed. 167 dismantling water tanks & removing from site, capacity of tanks exc 250 litres & n. exc. 500 litres capacity each 168 dismantling water tanks & removing from site, capacity of tanks 500 ltr and n exc 1000 ltr 169 s&f rotational moulded polyethelene water storage tanks ( cylindrical, vertical with closed top ) hoisted & fixed in position all as specified in ssr pt i, 500litre capacity. 170 s&f rotational moulded polyethelene water storage tanks ( cylindrical, vertical with closed top ) hoisted & fixed in position all as specified in ssr pt i, exc 1000 ltr capacity...

Military Engineer Services - Rajasthan

35811567 tender for repair maintenance of stps of age e / m under jaipur mil stn cleaning of treated water undergroud water storage sump of capacity 50, 000 gln at stp 1, 2, 3, 4 & 5 by specialized water tank clean tank cleanprocess as under : note 1 : all workers will wear mask and carry all necessary t&p for protection and smooth working before start cleaning process. the contractor will take prior permission from engineer in charge in written before starting work and will brief all aspect i.e date and time of cleaning start and completion so that suitable arrangment may be made to supply water during cleaning process. contractor will depute manpower in such manner that water supply time do not hamper. ( a ) mechanized dewatering and scrubbing the surface of floor and wall till removal of dirt, sendiments, fungus and the stains and cleaning, removal of sludge and shifting as directed. ( b ) high pressure cleaning. ( c ) soak the dirt and sendiments by vacuum cleaning. ( d ) anti bacterial spray on all dimensions inside tank. ( e ) m&l for marking date of cleaning on tank by using synthetic enemal paint, font design and letter size will be as directed by engineer in charge. ( 2 ) sludge / dirt and other sand debries etc will thrown out to place as directed by engineer in charge. ( 3 ) each stp shall be measured and paid as one job, if contractor failed / delayed after intimation for cleaning of each plant, penalty @ 20000 / shall be recoverd from his dues and contractors claim on this account shall not be entertained. 2 removing silt ( mud ) from sewage pump wellat stp 1, 2, 4&5 ( depth 7.5 meter, dia 8.5 meter ) and cleaning the bottom portion and sides of pump well by using man power at equal intervel of 6 months from date of commencement of contract, proper cleaning of sewage tank by following method complete all as mentioned in item no 3. 3 removing silt ( mud ) from sewage pump wellat stp 3 queens road ( size depth 7.5 meter, dia 3.5 meter covered with rcc roof and wall ) and cleaning the bottom portion and sides of pump well by using man power at equal intervel of 6 months from date of commencement of contract, proper cleaning of sewage tank by following method complete all as mentioned below: note for item no 2 and 3 : ( a ) all workers should be experienced for sewage pump well cleaning and necessary safety equipments including mask and other t&p for workers should be arranged by contractor before start cleaning process. ( b ) the contractor will take prior permission from engineer in charge in written before starting work and will brief all aspect i.e. date and time of cleaning start and completion so that suitable arrangement may be made. contractor will supply t&p and manpower in such manner that cleaning should be done without hampering sewage system.note ( 1 ) sludge / dirt and other sand debries etc will thrown out to place as directed by engineer in charge. ( 2 ) if contractor failed / delayed after intimation for cleaning of each plant, penalty@ rs 30000 / shall be recoverd from his dues and contractor s claim on this account shall not be entertained. 4 proper cleaning of rcc stilling chamber, rcc fine bar screen i&ii, rcc grit chamber i&ii, rcc oil and grease chamber, equalization tank, mbbr tank i&ii, flocculator, tube settler, cct, rcc filter feed tank, rcc slurry / sludge sump by experienced workers with safety equipments and t&p items required for cleaning of all above said parts of sewage treatment plant of 05 nos at equal intervel of 01month from date of commencement of contract complete all as mentioned below: ( a ) by mechanised dewatering and scrubbing the surface of floor, wall till removal of dirt, sediments and cleaning sludge removal and shifting as directed. ( b ) the contractor will take prior permission from engineer in charge in written before starting work and will brief all aspect i.e. date and time of cleaning start and completion so that suitable arrangement may be made. contractor will supply t&p and manpower in such manner that cleaning should be done without hamper sewage system.note ( 1 ) sludge / dirt and other sand debries etc will thrown out to place as directed by engineer in charge. ( 2 ) if contractor failed / delayed after intimation for cleaning of each plant, penalty @ rs 35000 / shall be recoverd from his dues and contractor s claim on this account shall not be entertained. 5 m&l for rectification of leakage from 50mm hdpe bore pipe line by cutting & replacement of defective hdpe pipe and refixing the same after cleaning and by connecting with old line with and including necessary fittings hdpe welding ( hot plate welding ) for old & new pipe includingnecessary exacavation & earth work as required complete all as specfied and directed . 6 all as per item no. 05 but for 100mm hdpe bore pipe 7 all as per item no. 05 but for 150mm hdpe bore pipe 8 all as per item no. 05 but for 250mm hdpe bore pipe 9 dismentling of centrifugal / monoblock pump set after disconnecting from power mains & pipe line of capacity 5 hp, 3 phase, 415 volts 50 hz, acof make kirloskar fromfoundation and dismantlingfor overhauling repairincludingreplacementof unservicablepart oiling , greasing, reinstalling and connecting with suction / dischargeline with correctalignment by replacing glandstuds and making completeelectricconnection includingtesting complete all as specifiedand directed. ( note spare parts required for replacement shall be measured and paid separetaly under respective items ) 10 transportation of motor to contractors work shop and back to site after repair, cutting of burnt winding & rewinding the stator with super enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles ete as per relevent is standard / manufacturers recommendation as directed by eic. 11 supply only stainless steel pump shaft as per existing make. 12 supply only gun metal impeller with neck key, distance bush as per existing make. 13 supply only ball bearing as per existing number and as per existing make. 14 m&l for dismantling the non clogging sewagepump ( 5.0 to 7.5 hp ) from foundation including electric and mechanical connection and taking out from 10 mtr deep sewage well with chain pulley block and instalation, reconnecting the electric and mechanical connection at existing location after carrying out minor repairs including replacement oil seal, oil, hanging chain etc all as specified and directed by engineer in charge. make :crompton greaves ltd, ksb ( note spare parts required for replacement shall be measured and paid separetalyrespective items. 15 transportation of motor to workshop and back to site after repair, cutting of burnt winding & rewinding the stator with super enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles ete as per relevent is standard / manufacturers recommendation as directed by eic. 16 supply only ball bearing nde and de as per existing numbers. make nde / de or equivalent as approved by ge. 17 all as per item no. 10 above but non clogging sewage pump ofcapacity 12.5 hp 18 transportation of motor to workshop and back to site after repair, cutting of burnt winding & rewinding the stator with super enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles ete as per relevent is standard / manufacturers recommendation as directed by eic. 19 supply only ball bearing nde and de as per existing numbers. 20 all as per item no. 10 above but non clogging sewage pump ofcapacity 3 / 4 hp 21 transportation of motor to workshop and back to site after repair, cutting of burnt winding & rewinding the stator with super enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles ete as per relevent is standard / manufacturers recommendation as directed by eic. 22 supply only ball bearing nde and de as per existing numbers. make nde / de or equivalent as approved by ge. 23 dismentling of centrifugal / monoblock pump set after disconnecting from power mains & pipe line of capacity 7.5 to 15 hp, 3 phase, 415 volts 50 hz, acof make kirloskar fromfoundation and dismantlingfor overhauling repairincludingreplacementof unservicablepart oiling , greasing, reinstalling and connecting with suction / dischargeline with correctalignment by replacing glandstuds and making completeelectricconnection includingtesting complete all as specifiedand directed. ( note spare parts required for replacement shall be measured and paid separetalyas supply only under respective item ) 24 transportation of motor to workshop and back to site after repair, cutting of burnt winding & rewinding the stator with super enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles ete as per relevent is standard / manufacturers recommendation as directed by eic. 25 supply only stainless steel pump shaft 26 supply only gun metal impeller with neck key, distance bush 27 supply only ball bearing as per existing number. 28 all as per item no. 13 above but centrifugal / monoblock pump ofcapacity 25 hp 29 transportation of motor to workshop and back to site after repair, cutting of burnt winding & rewinding the stator with super enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles ete as per relevent is standard / manufacturers recommendation as directed by eic. 30 supply only stainless steel pump shaft 31 supply only gun metal impeller with neck key, distance bush 32 supply only ball bearing as per existing number. 33 dismentling of filter press pump set, gear boxmotor after disconnecting from power mains & pipe line of capacity 1.5 hp to 2 hp , 3 phase, 415 volts 50 hz, acfromfoundation and dismantlingfor overhauling repairincludingreplacementof unservicablepart oiling , greasing, reinstalling and connecting with suction / dischargeline with correctalignment by replacing of gear road / pin and making completeelectricconnection includingtesting complete all as specifiedand directed. ( note spare parts required for replacement shall be measured and paid separetalyas supply only under respective items ) 34 transportation of motor to workshop and back to site after repair, cutting of burnt winding & rewinding the stator with super enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles ete as per relevent is standard / manufacturers recommendation as directed by eic. 35 supply only set of gear box as per existing model. 36 supply onlyneck key, distance bush 37 supply only ball bearing as per existing number. 38 supply only fan belt as per existing number. 39 m&l for taking out & servicing of existing air blower ( make everest, ) of capacity488 cum / hr from authorised service centre of everest company with taking out of electric cable complete and reconnecting the electric and mechanical connection at existing location after carrying out minor repairs including replacement of oil seal, oil, locking arrangement of pully, belt, gland packing etc all as specified and directed by engineer in charge. ( note spare parts required for replacement shall be measured and paid separetaly as supply only under respective items ) 40 supply only air filter suitable for above modelstainless steel pump shaft 41 supply only ball bearing ( make skf or equivalent as approved by ge ) 42 supply only set of rotor with hub as per existing model. 43 supply only set of gear with hub as per existing model. 44 taking out & rewinding the existing burnt blowermotor 20 hp, 3phase, 50 cycles by disconnecting electrically and mechanically and transporting to the locally contractors workshop. dismantlingthemotor and removing the old burnt copper winding & demoisturise, cleaning, rewindingthecoilswith same gauge super enamelled copper wire, with suitable f class paper insulation, varnishing, andreassembling by replacing bearings, remetalling of armature shaft and turning on lathe to give proper size for bearing fittings, replacement of terminal plate and reinstalling at the installation andtesting, commissioning etc complete.note before rewinding the existing motor, contractor must show the burnt motor / winding to the eic. old unserviceable copper retrieved will be property of contractor 45 supply & fix in repair pvc insulated, pvc sheathed, submersible flat cable isi marked with multi stranded copper conductor 1100 volt grade of size 6 sqmm 3 core of with pvc conduit of size 25mm dia for connecting pump from panel including heavy duty pvc conduit as per ground requirement complete all as specified and directed. 46 supply & fix in repair 3 pole power contactor type mnx 9 of ac3 9amp, 415v, 50 hz complete all as specified and directed. 47 supply & fix in repair contactor type mnx 32 of ac3 32amp, 415v, 50 hz complete all as specified and directed. 48 supply & fix in repair front mounting add on aux contact block mnx a2, 1no+1nc, 415v, 50 hz of make l&t, c&s, schneider or equivelent as approved by ge 49 supply & fix in repair control relay ( auxiliary contactors ) type mx0 22e ( 2no + 2nc ) , 415v of make l&t, abb, ae, or equivelent as approved by ge 50 supply & fix in repair mcb tp, c curve of capacity 6 amp to 32 amp 415v complete all as specified and directed. 51 supply & fix in repair mcb tpn, c curve of capacity 40 amp to 63 amp 415v complete all as specified and directed. 52 m & l for testing of treated water ( stp 1, 2, 3, 4&5 ) from regional govt approved test lab or nabl accredited lab. the undermentioned test should be carried out by each treated water sample and their characteristics will be as under: ( i ) biochemical oxygen demand ( bod ) < 10 mg / litre ( ii ) chemical oxygen demand ( cod ) < 150 mg / litre ( iii ) total suspended solids ( tss ) < 10 mg / litre ( iv ) dissolved oxygen ( do ) > 5 mg / litre ( v ) ph should be 6.5 to 8.5 ( vi ) residual chlorine > 0.5 mg / litre or more ( vii ) outlet coliform < 100 counts / 100ml note : ( i ) the frequency of all test should be once in a month at equal interval. ( ii ) ph and residual chlorine shall be tested on daily basis in the presence of je e / m / age e / m. ph meter and chlorine testing kit shall be provided by the contractor and cost of which shall be deemed to be included in the quoted rates. 53 m&l for rectification of leakage ( priming system ) from gi 15 / 20 mm size bore pipe line by cutting defective gi pipe by connecting with old line with and including necessary fittings such as socket & union, nipple, gate valveincluding screwingold & new pipe including all necessary earth work for connecting complete all as specified and directed. 54 s&f in repair of old u / sgland packing of valves / pump set of any sizes / capacity complete with neoprene rubber gasket , jointing material and nuts / bolts / washer of suitable size complete all as specified and directed. 55 s&f in repair ci foot valve isi marked with all fittings of size 100 mm dia 56 m & l for plaincement concrete 1:3:6 type c 1 ( 20mm graded aggregate ) in foundation filling mass concreting etc for making good the disturbed portion of road / floor / platform including form work etc complete all as specified and directed. 57 s&f in repairs electro magnetic diaphragm pump model v 12 having a capacity of 6.0 lph at maximum injection pressure of 3.5 kg / cm2 complete with pp head, fittings, footvalve, antisyphon valve and suitable to operate on 230 v / single phase / 50 hz ac supply including connecting to pipe line including testing complete as directed by eic. 58 servicing / overhauling ofsludge cake machinemake sachinfiltech pvt ltdafter disconnecting frompipe by authorised manufacturecompany, opening andchecking of various components andproper cleaning and greasing / oilingincd if any spare parts requiredfor repair and fuctioning of machine inclreplace compnay approved cloth as required each machine and pvc handle, knob, gear etcshall be deemed to be included in quoted rate of this item and testing of machine after repair complete and making sluge brick / rollall as directed by engr in charge. 59 labour only for checking the serviceability of different spares / component / parts of the starter and motor pump set / panel of any capacity at any site complete all as directed by engr in charge 60 supply and fix in repair of fullyautomatic star delta starter 10 hpcomprising of combo volt andammeter single phase preventor, over load relayand timer housed in ms sheet power coated enclosure of 10 hp capacity complete all as specified and directed. 61 supply and fix in repair ofstarter 5 hp comprising of combo volt andammeter, over load relayin ms sheet power coated enclosure complete all as specified and directed. 62 providing daily area cleaning / sweeping of preimises of following stp including cutting outgreen vegetation, roots, bushes, treebranches, picking polythene and other unwanted material from theinstallation area, spreading of suitable chemical to stop growing unwanted vegitation / grass and maintaining the ground surrounding the installation and removing the same out sidethe defence area as directed by engr in charge. the approx area of installation kept clean all as under.stp no 1 6000 sqm 63 all as per item no 35.01 here in before but stpno 02 4900 sqm 64 all as per item no 35.01 here in before but stp no 3 6100 sqm 65 all as per item no 35.01 here in before but raw sump hameed vihar 3000 sqm 66 all as per item no 35.01 here in before but stp no 4 8000sqm 67 all as per item no 35.01 here in before but stpno 05 12000 sqmnote : for item no 35.01 to 35.06 ( i ) if contractor fail is the clean the area of installation that recovery @ 5000 per job shall be recovered from his dues and contractors claim on this account shall not be entertained. ( ii ) contractor shall provide required t&p like as ( broom, axe, saw, bucket etc ) ( ii ) area will be maintained throughout the contract peroid from the date of commencement to date of completion and the payment will be made at once only. 68 m & l forci butterfly valve 100 mm dia, isi marked, complete with all fittings / accessories, required for fixing complete all as specified and directed 69 m&l for water high pressure gauge including socket welded to measure pressure in the deliverypipe 0 150 psi kg / cm2 make fe / big / guru, ramco or equivalent as approved by ge 70 earthing complete with glavanised steel earth plate elactrode 600mm x600mm x6.0 mm thick buried directly in ground ( earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to galvanised earth lead strip 25 x 4mm sizeby means of nut , bolt, check nut and washer ofgalvanised iron or of steel, earth lead protected by 40 mm dia gi pipe light grade watering pipe 20 mm dia gi light grade gi wire meshed funnel alternate layer of charcoal and salt pcc chamber , recessed for and including rcc cover including all necessary excavation and earth work, earth wire connected to main switch board, testing the earthing after completion all as specified and shown in electric plate no 3 of mes ssr pt i 2009 print, complete all as specified & directed ( pannel earthing ) . 71 taking out non clog sewage lifting pump set of cap5 to 12.5 hp, 3 phase, 415 volts, 50hz, ac supply along withpipe from the sewage collection well andremoveing mud, plastic, cloth, poleythen, stone etc completeand testing then lowering the same after cleaning complete all as specified and directed 72 taking out old unserviceable pvcbio filter media filling and m&l pvcbio filter mediafilling for mbbbr as per exisiting size all as directed by engr in charge. 73 material and labour for fabrication of retro reflectroised sign board of size exceeding 0.90 sqm as per irc : 67 made of encapsulated lens type reflective sheeting, fixed over aluminium sheet 1.5 mm thick of required size duly written with thematter as directed in blue colourmounted on angle iron / ms pipe support complete and including grouting the sign board in brick work, plastered and white wash on all exposed surfaces or in pcc 1:2:4 type b 2 using 40 mm graded stone aggregate complete all as directed by engineer in charge.note – ( i ) angle iron frame work, pcc, brick work, plastering and white wash shall be measured and paid for separately under appropriate item of schedule a ( ii ) retro reflective sheet and letters shall be astm 4956 type 3 of high intensity grade of make: 3m grade 3870 / kiwalite 22000 / avery dennison series 6200 or equivalent as approved by ge 74 material and labour for mild steel frame work confirming to fe 290 ( gde e 165 ) of sign boards made of m s angle iron or ms square or round pipe of suitable thickness and size as directed duly painted with two coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces complete all as directed and specified by engineer in charge.note : the surface of angle iron coming in contact with pcc / brick work shall be painted with two coats of bituminous paint and rate quoted for above item shall be deemed to inclusive of same. 75 s & f for rotational moulded polyethylene water cantainer500 litres capacity ( cylindrical vertical with lid ) , double layer, isi marked, fixed in position with pp head, fittings, footvalve, antisyphon valve, end block plateincluding connecting to pipe line assuitable length including testing complete as directed by eic. 76 all as per item no. 44 above but capacity 1000 litres. 77 providing / fabrecation in replacement of fire point stand made out of angle iron 40x40x5mm thickand canopy roof made out of mssheet 22 gauge thick incl provision for hanging 03 buckets fill with sandincluding 02 nos fire extingusher a / b / c type incl pcc foundation, pick axe, belcha complete sample drg approved by engr in charge before fabrication 78 supplying, laying, jointing and testingductile iron pressure pipe centrifugally castisi marked with socket and spigot ends including all necessary fittings with jointing materialsconforming to is 8329 / 2000 standard length , of k7 specification with out zinc coatinglaid in trenches, under floor, road etc of following dia sizes including taking out old unsv hdpe / pvc pipe : 150 mmmake jindal ltd / electrosteel casting ltd / tata or equivalent as approved by ge 79 all as per item no 47.01 here in before but 100 mm 80 m&l for rendering 10 mm thick cement plaster in cm 1:4 on stone masonary orfaces of brick work including finished even and smooth without using extra cement including taking down old complete all as directed. 81 excavation & earth work in trenches n.exc 1.5m wide and n.exc 1.5m in depth and getting out in soft and loose soil including trimming of sides and bottom of trenches complete all as specified and directed. 82 returning, filling in, including spreading, watering and well ramming in layers n.exc 25cm thick each in soft / loose soil complete all as specified and directed. 83 removing excavated surplus soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting pointcomplete all as specified and directed. 84 m & l for 3 layer pp r ( polypropylene random copolymer ) concealed pipes sdr 7.4 pn 16 uv stabilised and antimicrobial fusion welded having thermal stability for sewage treated water supply and including all types required fittings with pp r plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed of the following sizes : 75 mm dia note :wall thickness of pipe shall beas per is 1580 ( make zindal / sfmc / kanha plastic pvt ltd or equivalent as approved by ge ) 85 all as per item no 52 here in before but 50 mm dia 86 all as per item no 52 here in before but 25 mm dia 87 all as per item no 52 here in before but 15 mm dia 88 disconnecting exisitng lt over heated or burnt cable terminal / joint at panel / feeder pillar & lt cable of any size cutting out over heated / burnt / unserviciable portion of cable, stretching / opening cable to suitable required length etc and fixing aluminium lugs / joint material and suitablenuts bolts & washeretc all as direeted by engr in charge 89 supply and fix of flex board of water installation and machine specification board size 45cm x 60cm fix on fronteach and every equipment , machiney specification given by engr in charge 90 m&l foructech 01 ( liquid floculant ) using for the de established colloidal particales together to form large aggregates of sewage water, dozing 2.5 kg / 50 ppm per day ( for two times ) and using at the time of peak water flow in a settling tank complete all as specified and directed. make : urveeka chemteck pvt ltd, or euivalent makeas approvedby ge 91 m&l for uctech 02 ( liquid coagulant ) using for neutralizing the non settleable particles & allow to form clumps of sewage water, dozing2.5 kg / 50 ppm per day ( for two times ) and using at the time of peak water flow in a settling tank complete all as specified and directed.make : urveeka chemteck pvt ltd, or euivalent makeas approvedby ge 92 m&l for uctech 04 ( liquid disinfectant ) using for deal with bacterial problem and make fare color ofwater, dozing 4 kg / 80 ppm per day ( for two times ) and using at the time of peak water flow in a holdingtank complete all as specified and directed. make : urveeka chemteck pvt ltd, or euivalent makeas approvedby ge 93 m&l foructech 03 ( liquiddeodprizer ) using for stop biological fouling in working zone and make odorless water to provide healthy environment of sewage water , dozing 3 kg / 60 ppm per day ( for three times ) and using at the time of peak water flow in a collectiontank complete all as specified and directed.make : urveeka chemteck pvt ltd, or euivalent makeas approvedby ge 94 m&l for uctech 07 ( nutrient chemical ) using for maintain the ph in 7 8 range to sustain quality of water as per pollution control normof water , dozing 5 kg in a week ( for two times ) and using at the time of peak water flow in a aerationtank complete all as specified and directed. make : urveeka chemteck pvt ltd, or euivalent makeas approvedby ge 95 m& l preparing old steel surfaces and applying one coat of synthetic enamel paint as per existing colour such as ( pipe line, filter tank and pump etc ) including marking ofarrow sign and name in capital letter with black synthetic enamel paintthe following equpt each stp ( i ) treated pump 02 nos ( ii ) filter feed pump 02 nos ( iii ) air blower 02 nos ( iv ) press filter motor 02 nos ( v ) suction / discharge line ( vi ) filter 02 nos 96 s&f 1.25 meter length of gi 20mm dia size medium grade pipe as tapping point pipe by providing 20mm dia bore gate valve with excavation of earth& refilling complete for trenches of size 2.0 x 1.0 x 1.0 meter for existing pipe line dia by proper punching for water tapping& connected with suitable saddle / clamp of size 25 x 3 mm with nut bolts & accessories complete & in pcc ( 1:3:6 ) , type c1, using 20mm graded stone aggregate for stand post of size 200 x 200 x 300mm testing & commissioning on water pressure complete as directed by eic. 97 supply and fix in repair mccb tpn 63 amp to 100 amp , 415 volts, 50 hz 35ka complete all as specified and directed. 98 supply and fix in repair mccb tpn 200 amp , 415 volts, 50 hz 35ka complete all as specified and directed. 99 supply and fix in repair mccb tpn 250 amp , 415 volts, 50 hz 35ka complete all as specified and directed. 100 s&f in repair submersible copper cable pvc insulated over all sheethed flat isi marked of 1100 volts grade of 10 sqmm 3 core. ( make: finolex / l&t / havells ) 101 s&f in repair submersible copper cable pvc insulated over all sheethed flat isi marked of 1100 volts grade of 6 sqmm 3 core. ( make: finolex / l&t / havells ) 102 s&f in replacementair pressure pipe as per existing size approx 6mtr long for connection filter press pump machine incl connection fitting , clamp , nozel etc including testing complete as directed by eic. ...

Rajasthan Rajya Vidhyut Prasaran Nigam Limited - Rajasthan

35708195 work of laying of earth mesh, earthing of sub station structure and equipment, erection of steel structure and equipment, stringing of bus bar and earth wires, jumpers, installation of control panels, cable laying and termination of cable etc at 132k...

Rajasthan Rajya Vidhyut Prasaran Nigam Limited - Rajasthan

35704107 work of laying earthmesh, earthing of sub station structures and equipments, stringing of bus bar and earth wires, jumpers, installation of control panels, cable laying and termination of cable etc. at 132kv gss barawarda on labour contract basis....

Rajasthan Rajya Vidhyut Prasaran Nigam Limited - Rajasthan

35696631 work of laying of earth mesh earthing of sub station structure and equipment erection of steel structure and equipment, stringing of bus bar and earth wires jumpers installation of control panels cable laying and termination of cable etc at 132kv...

Rajasthan Rajya Vidhyut Prasaran Nigam Limited - Rajasthan

35690731 tender for work of laying of earth mesh earthing of su station structure and equipment, stringing of bus bar and earth wires jumper, installation of control panels, cable laying and termination of cable etc. at 132 kv dss barawarda on labour contract basis....

Military Engineer Services - Rajasthan

35594842 tender for welcome maintenance at jalipa mil stn under ge army barmer taking down cement plaster of any description, on brick or stone walls etc.including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. ( note : work will be done / executed in patches without damaging other undamaged portion, of any size as directed ) 2 m&l for rendering 10mm thick plaster in cm ( 1:6 ) on faces of brick work or concrete surfaces, finished even and smooth ( without using extra lime or cement ) complete all as specified and directed. 3 m&l for rendering 5mm thick plaster in cm ( 1:3 ) on faces of brick work or concrete on surfaces of ceiling, finished even and smooth without using extra cement complete all as specified and directed. 4 m&l for rendering 15mm ( in two layers 10mm+5mm ) thick plaster in cm ( 1:4 ) on faces of brickwork or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. 5 m&l for preparing new plastered or unplastered surfaces of walls and applying two coats of oil emulsion distempering over a coat of interior wall primer complete all as specified and directed. 6 m&l for preparing new plastered or unplastered surfaces of walls and applying three coats of white wash complete all as specified and directed. 7 m&l for preparing new plastered or unplastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. 8 m&l for 3mm thick wall care putty on wall complete all as specified and directed. 9 m&l for preparation of new plastered surfaces of walls and applying two coat of cement based paint over a coat of primer complete all as specified and directed. 10 hacking out old broken glass ( any thickness, size, quality or description ) from from metal frame including punching or drilling out old glazing pins / spring clips, glazed with putty or fixed with beads and providing and fixing new ones complete all as specified and directed. 11 m&l for 3mm thick sheet glass, ordinary quality and glazing with oil putty in square in n exc 0.5 sq.m in each pane complete all as specified and directed. 12 m&l for 3mm thick figured glass, pin head type and glazing with oil putty in squares in n exc 0.5 sq.m in each pane complete all as specified and directed. 13 m&l for preparing old plastered or unplastered surfaces of walls including filling of cracks / holes by crack filler, removing unnecessary nails and applying one coat of white wash complete all as specified and directed. 14 m&l for preparing old plastered or unplastered surfaces of walls, including filling of cracks / holes by crack filler, removing unnecessary nails and applying two coats of white wash complete all as specified and directed. 15 m&l for complete removal of existing treatment, plastered or unplastered old surfaces of walls, including filling of cracks / holes by crack filler, removing unnecessary nails and applying three coats of white wash complete all as specified and directed. 16 m&l for preparing old plastered or unplastered surfaces of ceiling, including filling of cracks / holes by crack filler, removing unnecessary nails and applying one coat of white wash complete all as specified and directed. 17 m&l for preparing old plastered or unplastered surfaces of ceiling, including filling of cracks / holes by crack filler, removing unnecessary nails and applying two coat of white wash complete all as specified and directed. 18 m&l for complete removal of existing treatment, plastered or unplastered old surfaces of ceiling, including filling of cracks / holes by crack filler, removing unnecessary nails and applying three coats of white wash complete all as specified and directed. 19 m&l for preparing old plastered or unplastered surfaces of walls including filling of cracks / holes by crack filler, removing unnecessary nails and applying one coat of oil bound distemper / emulsion complete all as specified and directed. 20 m&l for preparing old plastered or unplastered surfaces of walls including filling of cracks / holes by crack filler, removing unnecessary nails and applying two coats of oil bound distemper / emulsion complete all as specified and directed. 21 m&l for complete removal of existing treatment, plastered or unplastered old surfaces of walls, including filling of cracks / holes by crack filler, removing unnecessary nails applying two coats of oil bound distemper / emulsionover a coat of interior wall primer over 3mm thick wall care putty complete all as specified and directed. 22 m&l for preparing old plastered or unplastered surfaces of walls including filling of cracks / holes by crack filler, removing unnecessary nails and applying one coat of cement based paint complete all as specified and directed. 23 m&l for preparing old plastered or unplastered surfaces of walls, including filling of cracks / holes by crack filler, removing unnecessary nails and applying two coats cement based paint complete all as specified and directed. 24 m&l for preparation of old painted wood and wood based surfaces of any description over 10cm in girth or width and painting with one coat of synthetic enamel paint complete all as specified and directed. 25 m&l for preparation of old painted wood and wood based surfaces of any description over 10cm in girth or width and painting with two coats of synthetic enamel paint complete all as specified and directed. 26 m&l for preparation of old painted steel or iron surfaces of any description over 10cm in girth or width and painting with one coat of synthetic enamel paintcomplete all as specified and directed. 27 m&l for preparation of old painted steel or iron surfaces of any description over 10cm in girth or width and painting with two coats of synthetic enamel paintcomplete all as specified and directed. 28 demolition of stone slabs and tiles laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc complete all as specified and directed. 29 m&l for granite ( of any type ) 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting andpolishing types including 15mm thick screed bed in cm ( 1:6 ) , complete all as specified and directed. 30 m&l for glazed ceramic tilesof size350mm x 250mm x 7mm / 450mm x 350mm x 7mm thick ( coloured ) of superior qualityfixed on vertical surfaces such asskirting / dado etc, set and jointed in neat cement slurry over 10mm thick backing coat in cm ( 1:4 ) and pointed in coloured cement to match complete all as specified and directed. 31 m&l for non skidceramic tiles of size 7 to 8mm thick ( coloured ) ( square / rectangular ) area of each tile exc 0.06 but n exc 0.11 sqm, in floors, set & jointed in neatcement slurry and pointed in coloured cement over 15mm thick screed bed in cm ( 1:6 ) complete all as specified and directed. 32 taking up or down 15mm bore steel water tubing & connections from walls / ceilings / floors including cleaning for refixing or removal to store all as specified and directed. 33 taking up or down 20mm bore steel water tubing & connections from walls / ceilings / floors including cleaning for refixing or removal to store all as specified and directed. 34 s&f for 16mm bore of cpvc of food grade pipes sdr 11 and plain cpvc sdr 11 fittings on walls / ceiling or laying in floors complete all as specified and directed. 35 s&f for 20mm bore galvanized iron tubes, medium grade, with all fittings, fixed complete to walls, ceilings or laid in floors all as specified and directed. 36 cutting chases in brick walls, stone, concrete block or slab walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth all as specified and directed. 37 s&f in repair 150 mm long aluminium anodizes barrel tower bolts of extruded section complete all as specified and directed. 38 s&f in repair 150mm size aluminium anodized handle complete all as specified and directed. 39 s&f in repair 250mm long aluminium alloy anodized sliding door bolts with hasp and staple ( bolt type ) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. 40 s&f in repair mild steel ordinary rat tail rod pattern spring 300mm size including roller & roller plate and incl welding complete all as specified and directed. 41 s&f in repair 100mm size mortise lock, aluminium, vertical type, four leavers, all as specified and directed. 42 s&f in repair pvc cabinet 450x600mm overall size with looking mirror of selected qality 5mm thick glass mounted over pvc framing as per sample complete all as specified. ( make : neelkamal / prayag ) 43 s&f in repair 450mmx600mm bevelled edge mirror of selected quality glass, mounted on 6mm thick ac building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed. 44 s&f for brass knobs 35 40mm dia complete all as specified and directed. 45 s&f ball catches with 8mm dia steel ball, and brass body and striking plate 140mm length including letting in and fixed complete all as specified and directed. 46 s&f in repair aluminium floor door stoppers double legged length 140mm with hard drawn steel spring fitted in floor complete all as specified and directed. 47 dismantling of boarding any description fixed in any position with nails complete all as specified and directed. 48 m&l for prelaminated particle board of 18 / 19mm thick, interior grade prelaminated one side with decorative choice lamination & other side balancing white lamination with teak wood leaping on exterior face, fixed with screws as in cupboard shutters of bed room, kitchen andinternal shelves complete all as specified and directed. 49 s&f width of flaps ( when open ) in 40 mm continuous ( piano ) hinges, mild steel, bright finish or electrogalvanised complete all as specified and directed. 50 s&f for 75mm size ms butt hinges cold rolled medium weight complete all as specified and directed. 51 s&f in repair stainless steel wire cloth 0.36mm nominal dia of wire andaverage width of aperture 1.40mm and fixed with stainless steel wire stapples of any type of windows and doors i.e. wooden, steel or aluminium including opening and refixing of frame, shutter or shutter elements if required and new wooden beads in wooden doors, complete all as specified and directed. 52 s&f in repair 20mm dia stainless steel curtain rod with fancy type fixing brackets, stops, rollers etc. complete all as specified and directed. 53 s&f in repairs mild steel window handles of approved quality with fixing nuts complete all as specified and directed. 54 s&f in repairs ms peg stay for steel window 300mm long with nuts complete all as specified and directed. 55 s&f in repair 15mm bore bib taps cp fancy type, cast copper, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. 56 s&f in repair 15mm bore dia pipe cp wall mixer for mixing ( hot / cold ) water, with wall cap / band of cp brass, screwed down, screwd foriron pipes 15mm bore complete all as specified and directed. 57 s&f in repair 15mm bore brass cp sink mixer fancy type with swinging casted spout ( wall mounted type ) for kitchen sink screwed down for iron pipe and fixed complete all as specified and directed. 58 s&f in repair 15mm bore centre hole basin mixer fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered `hot and `cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed. 59 s&f in repair 15mm bore cp fancy type stop valves / angle cock, cast copper alloy, screwed both ends for iron pipe or for union complete all as specified and directed. 60 s&f in repair 15mm bore two way bib taps ( for health faucet / jet spray ) fancy type, chromium plated, cast copper ally with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. 61 s&f in repair 32mm dia pvc waste pipe for whb / sink complete all as specified and directed. 62 s&f in repair 15mm bore, 450mm long, pvc connections with brass unions internally threaded both ends complete fixed to iron pipe at both ends as fixed in repairs complete all as specified and directed. 63 s&f in repair vitreous china wash down water closet pan ( pedestal pattern ) , white including p or s trap, connection to drain ( or outgoing pipe ) and to flushing pipe with and including plastic water closet seat, white closed pattern with flat bottom, cover and mild steel hinges device complete all as specified and directed. 64 s&f in rep vitreous china squatting pan “orissa” pattern, of size 580mm x 440mm white with integral foot rests and trap ( excluding flushing cistern and flush pipe ) including trap and provn of cement concrete bedding complete as fixed complete all as specified and directed. 65 s&f in repairs wash hand basins, vitreous china, of size 550x400mm ( flat back, or angle back type ) including cutting for and pinning in ends of brackets or erecting standinclusive of fixing of supply and waste pipe etc complete all as specified and directed. 66 s&f in repair plastic water closet seat for pedestal / semi pedestal closet pan, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified. 67 s&f in repair pvc valveless flushing cistern, low level white with inlet ball valve float and handle including brackets complete fixed capacity of flush 10 ltrs complete all as specified and directed. 68 s&f in repair brass chromium plated shower rose 125mm size complete all as specified and directed. 69 s&f in repair health faucet ( abs body ) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and abs wall hook including making connections and fixed in position complete in all respect complete all as specified and directed. 70 s&f in repair ss soap dish, approximate size 150x 150x80mm, fixed to plugs with chromium plated brass screws complete all as specified and directed. 71 s&f in repair toilet paper holder with flat recessed type stainless steel fixed to walls with chromium plated ( cp ) brass screws complete all as specified and directed. 72 s&f in repair sheet glass corner wall mounted shelf assembly consisting of 8mm thick sheet glass 220mmx220mm size with chromium plated bracket guard and railing 50mm high complete all as specified and directed. 73 s&f in repair brass chromium plated tubular towel rail 20mm dia, d type, 60cm long between flanges complete all as specified and directed. 74 s&f in repair jet spray ( abs body ) mild steel chromium plated suitable for 15mm dia pipe with 1.00 metre long flexible tube including making connections and fixed in position complete in all respect complete all as specified and directed. 75 s&faluminium window / ventilator frame with side hung shutters ( fully glazed ) and aluminium grill 7.50mm thick as per design code no. 007 of dural grill or equivalent make as approved comprising of chokhat and shutters weight not less than 0.55kg / rm including jointing cleat, aluminium snap beading 20x15mm, rubber gasket, glazing clip, sheet glass 3.00mm thick selected quality for panels and aluminium hardware fitting fixed with steel chromium plated screws such as 02nos, 100mm size aluminium d type handles, 02 nos 75mm size stainless steel medium weight hinges, 02nos 100mm long aluminium tower bolts, one peg stay 150 mm long etc including taking down complete all as specified and directed . 76 s&f powder coated aluminium door frame with side hung shutters ( fully glazed ) comprising of chokhats section 101.04 x 44.45 x 1.5mm thick, shutter top rail 86.17 x 44.45 x 2.3mm, bottom and lock rail 150 x 44.45 x 2.3mm and style 53.7 x 44.45 x 2.3mm and including jointing cleat, aluminium snap beading 20 x 15mm, rubber gasket, glazing clip, sheet glass 5.5mm thick figured / solar control film glass selected quality for panels and aluminium hardware fitting fixed with steel chromium plated screws such as 02 nos disc type round handles, 03 nos 100mm size hinges, 03 nos 150mm long tower bolts, one floor door stopper with hard drawn steel spring 140mm long, 01 number of double action floor spring hydraulically regulated made upto minimum 1.25mm thick aluminium alloy sheet junction box for each leaf main body with stainless steel sheet cover governing pivot of brass, other parts made of mild steel heavy duty etcincluding taking down complete complete all as specified and directed. 77 s&f aluminium door frame with side hung shutters ( fully glazed ) comprising of chokhats section 101.04 x 44.45 x 1.5mm thick, shutter top rail 86.17 x 44.45 x 2.3mm, bottom and lock rail 150 x 44.45 x 2.3mm and style 53.7 x 44.45 x 2.3mm and including jointing cleat, aluminium snap beading 20 x 15mm, rubber gasket, glazing clip, sheet glass 5.5mm thick figured / solar control film glass selected quality for panels and aluminium hardware fitting fixed with steel chromium plated screws such as 02 nos disc type round handles, 03 nos 100mm size hinges, 03 nos 150mm long tower bolts, one floor door stopper with hard drawn steel spring 140mm long, 01 number of double action floor spring hydraulically regulated made upto minimum 1.25mm thick aluminium alloy sheet junction box for each leaf main body with stainless steel sheet cover governing pivot of brass, other parts made of mild steel heavy duty etc including taking down complete all as specified and directed. 78 m&l for prepration of surface by cleaning to remove loose particles, dust, latance etc, cutting grooves again remove loose particles, dust, latance etc properly, filling cracks / damaged portions / hollow areas / gaps of rcc and masonary upto 10mm to 15mm widhth and 10mm to 20mm deep by using polymer modified cement mortars and making good surface like existing painted surface with the help of cement mortar and paint all directed and as per manufacturers instructions. make : m / s asian paint / berger / m / s pidilite industries ltd / stp ltd / choksey. 79 m&l for prepration of preparation of new / old decorated plastered or unplastered surfaces of walls / chajjas by cleaning to remove loose particles, dust, latance etc., filling of holes / cracks with cns filler material. applying one priming coat ofsmart care damp proof with thinner at the rate of 0.40 ltr / sqm ( 0.20ltr smart damp proof : 0.20ltr water ) . applying second coat ofsmart care damp proof after 05 to 06 hrs at the rate of 0.40 ltr / sqm, and apply the third coat after 6 to 8 hrs once the second coat is dry at the rate of 0.40 ltr / sqm all directed and as per manufacturers instructions. make : m / s asian paint / berger / pidilite industries ltd / stp ltd. / choksey. note : cracks filler, priming coat and damp proofing coat shall be used of same make / manufacturer. 80 taking down copper / aluminium point wiring ( light, fan, socket or power ) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing unserviceable materials for taking credit ( credit for above items should be made as per conditions separately ) and making good disturbed surfaces of walls, floors etc complete all as specified and directed. 81 taking down unserviceable main switch / db, teak wood boards etc complete all as specified and directed 82 taking down old unserviceable sub main wiring and making good the disturbed surfaces complete all as specified and directed. 83 m&l for point wiring surface type with single core 1.5 sqmm pvc insulated unsheathed single core multistranded copper conductor cable ( frls ) including 1.5 sqmm pvc insulated unsheathedcopper conductor as earth continuity conductor drawn in and including isi marked pvc casing caping not less than 20mm width with its accessories, including necessary modular metal flush box / pressed steelterminal boxes and modular white cover plate / 3 mm thick isi marked laminated sheet cover and ss screws with cup washers for fixing switches, sockets, fan regulators etc. including making good disturbed surfaces if any with cement mortar 1:3 for fixing switches / sockets / regulators etc. for one light point controlled by one switch complete all as specified and directed. 84 all as per srl item no 83 above but for call bell point controlled by one switch. 85 all as per srl item no 83 above but for one light point controlled by two 2 way switches. 86 all as per srl item no 83 above but for one fan point controlled by one switch. 87 all as per srl item no 83 above but for one 3 pin 5 amps socket outlet point on independent board. 88 all as per srl item no 83 above but for one 3 pin 5 amps socket point on the same board with other switches. 89 all as per srl item no 83 above but with cable 2.5 sqmm including 2.5 sqmm cable as earth wire for 15 / 16 amp socket. 90 all as per srl item no 83 above but with cable 4 sqmm including 4 sqmm cable as earth wire for 15 / 16 amp socket. 91 m & l switch piano, flush type single pole, one way 5 amps complete all as specified and directed. 92 m&l socket outlet 2in1, 3pin, 5a complete all as specified and directed. 93 m&l switch socket combination 2 in 1, 3 pin, 5 amps and 15 amps flush type universal complete all as specified and directed. 94 m&l ceiling rose surface bakelite 65x50 mm two to three terminals complete all as specified and directed. 95 supply and fix steped type electronic fan regulator flush type, 230 volt, ac complete all as specified and directed. 96 m&l bell push, flush type, 5 amps complete all as specified and directed. 97 m&l call bell ac, 230 volts single pole complete all as specified and directed. 98 supply and fixing 06 to 32 a rating 240v, 10 ka c curve miniature circuit breaker ( mcb ) of single pole and current carrying capacity in the mcb db complete with connection testing and commissioning complete all as specified and directed. 99 all as per srl item no 98 above but spn 6 32 amps. 100 supply and fixing 415v 10ka c curve miniature circuit breaker ( mcb ) of tripple pole and neutral ( tpn ) and current carrying capacity 40 to 100 a in the db complete with connection testing and commissioning complete all as specified and directed. 101 supply and fix single pole and neutral enclosures with a two pin and earth plug and socket complete with one double pole mcb 20 a, 240 v complete all as specified and directed. 102 s&f mcb, db double door type, made out of crca mild steel sheet flushed in wall, spn 8 way , 240 volts ip 43, with pvc mcb blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of mcbs and isolators etc including complete all as specified and directed. 103 s&f mcb, db double door type, made out of crca mild steel sheet flushed in wall, tpn 4 way with 200 amps rated bus bar , 415 volts ip 43, withpvc mcb blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of mcbs and isolators etc includingcomplete all as specified and directed. 104 m&l sub main wiring surface type with two runs of single core, pvc insulated, unsheathed multi standard copper conductor cable of size 4 sqmm, 1100 volts grade ( frls ) and one run of 4 sqmm pvc insulated multi stranded copper conductor for earth continuityconductor drawn through and including suitable size isi marked rigid pvc conduit with all necessary accessories such as bends, tees, junction boxes, elbowscomplete all as specified and directed. ( note : two runs of 4 sqmm cable, one run of 4 sqmm continuity earth wire and one run of pvc conduit with all necessary accessories will be measured as one length ) . 105 m&l sub main wiring surface type with two runs of single core, pvc insulated, unsheathed multi standard copper conductor cable of size 6 sqmm, 1100 volts grade ( frls ) and one run of 6 sqmm pvc insulated multi stranded copper conductor for earth continuityconductor drawn through and including suitable size isi marked rigid pvc conduit with all necessary accessories such as bends, tees, junction boxes, elbowscomplete all as specified and directed. ( note : two runs of 6 sqmm cable, one run of 6 sqmm continuity earth wire and one run of pvc conduit with all necessary accessories will be measured as one length ) . 106 supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 v, 1200 mm sweep, min air delivery 210 cfm with service value 6.00 bee. five star rated with brushless direct current motor ( bldc ) complete including connecting with 3 core flexible copper conductor including taking down the existing ceiling fan and depositing the same in mes store complete all as specified and directed. 107 supply and fix ceiling fans, complete with three blade, down rod, accessories 230v, 1200mm sweep, with squirrel cage induction motorcomplete including connecting with 3 core flexible copper conductor including taking down the existing ceiling fan and depositing the same in mes store complete all as specified and directed. 108 supply and fix exhaust fan, steel body ac single phase. 230v of size 300m sweep with, blades, and frame and louvers complete including connecting with 3 core flexible copper conductor including taking down the existing exhaust fan and depositing the same in mes store complete all as specified and directed. 109 supply and fix exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230v, 50 hz, rpm 1200, copper winding of sweep 250mm complete including connecting with 3 core flexible copper conductor including taking down the existing exhaust fan and depositing the same in mes store complete all as specified and directed. 110 supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 kw capacity 25 litre, bee 5 star rated complete with all accessories such as safety valve, thermostate, nrv, connection piece etc. and fixing on wall with toggle bolts and connecting with pvc flexible pipe complete including taking down the existing storage water heater and depositing the same in mes store complete all as specified and directed. note: pvc connection pipe, ground toggle bolts for fixing water heater will be measured and paid separately under relevant items. 111 supply only ground toggle bolts ( tower / anchor ) , 6 long along with washers and nuts for fixing geysers 25 / 50 ltrs capacity. 112 supply only pvc connection 15 mm bore with ptmt nuts of length 600mm in repairs complete all as specified and directed. 113 supply only pvc metal braided connection pipes for hot water supply with brass adopters 600mm long. 114 supply and fix in repair led bldg security light fitting 25 watt 230 v ac outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with ip 65 / 66 protection complete all as specified and directed. 115 supply and fix in repair led lights fitting 1x 20w, 220v, ac decorative box type with driver, holder including led tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed 116 supply and fix in repair led light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 v ac decorative type with driver holder and led lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. 117 s & f in repair led light fitting 1x9w / 1x10wbulkhead luminaires including led light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. 118 supply and fix in repair lamp holder, pvc / polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. 119 taking out old u / s rubber reel of ceiling fan any make / size and supply and fixing heavy duty shackle type rubber reel complete with clamps. nut, bolt with split pin and washers complete all as specified and directed. 120 taking out defective capacitor and supply and fixing capacitor of rating 2.5 / 3.15 mfd230 vall as specified and directed. 121 supply & fix in repair fan regulator electronic step type 300 watt 240 volts including dismantling of old unserviceable regulator complete all as specified and directed. 122 supply and fix in repair modular switch 1 way 6 a, 1 module complete all as specified and directed. 123 supply and fixin repair modular switch 1 way 16 a, 1 module complete all as specified and directed. 124 supply and fixin repair modular bell push 6 a, 1 module complete all as specified and directed. 125 supply and fix in repairmodular socket, 6 a 2 / 3 pin combined 2 module complete all as specified and directed. 126 supply and fixin repair modular socket, 6a / 16a 2 / 3 pin combined 2 module complete all as specified and directed. 127 supply and fix in repair switch piano, flush type single pole, one way 5 amps complete all as specified and directed 128 supply and fix in repair switch socket outlet 2in1, 3pin, 5a complete all as specified and directed 129 supply and fixin repair switch socket combination 2 in 1, 3 pin, 5 amps and 15 amps flush type universal complete all as specified and directed 130 supply and fix in repair bell push, flush type, 5 amps complete all as specified and directed. 131 supply and fixin repair call bell ac, 230 volts single pole complete all as specified and directed 132 s&f in repair pvc board 30 x 25 x 5 cm depth medium quality isi marked complete all directed. for fixing of switches, sockets and regulators including taking down the old one complete all as specified and directed. 133 m & l for inverter point wiring forlight, ceiling fan and 5 amp socket with 2.5 sqmm, pvc insulated, unsheathed, single core multistandard copper conductor cable ( frls ) , 1100 volts grade including 2.5 sqmm pvc insulated, unsheathed, copper conductor cable for earth continuity wire to be drawn through in and including pvc conduit medium grade isi markedwith its acessories upto the main dband 15 a switch socket combination with gang box flushed in wallfor inverter power supply complete all as specified and directed....

Military Engineer Services - Rajasthan

35548989 tender for welcome maintenance and misc b / r and e / m items in single / md offrs accn under ge jaipur at jaipur mil stn taking down cement plaster on brick / stone wall, ceiling etc incl. raking outs joints hacking for key scrubbing with water complete all as specified and directed 2 m&l for rendering 15mm thick on fair face of brick or concrete surface in cm ( 1:6 ) surface finished even and smooth without using extra cement complete all as specified and directed 3 m&l for preparation of newly plastered or unplastered surface of wall and applying two coats of exterior emulsion weather proof paint and one coat of primer on walls complete all as specified & directed 4 m&l for preparation of newly plastered or unplastered surface of wall and applying two coat of interior emulsion weather proof paint and one coat of primer on walls complete all as specified & directed 5 m&l for preparing old painted surfaces of steel using sand paper gentle rubbing to obtain smooth surfaces and applying two coat of synthetic enamel paint complete all as specified. 6 m&l for complete removal of existing treatment and applying two coat of exterior emulsion weather proof paint and one coat of primer on walls complete all as specified & directed 7 m&l for complete removal of existing treatment and applying two coat of interior emulsion weather proof paint and one coat of primer on walls complete all as specified & directed 8 m&l for complete removal of existing treatment and applying two coat of interior emulsion weather proof paint and one coat of primer on ceiling surface complete all as specified & directed 9 m&l for preparing old surface of wall and applying acrylic paint on wall, jallie, rcc pillars etc complete all as specified & directed 10 m&l forpreparation of surfaces and applying two coat of varnishing to old wooden surfaces over 10cmwidth or girth complete all as specified & directed 11 m&l for preparing old painted surfaces of wood or wood based materials over 10 cm width or girth of any description & applying two coat of synthetic enamel paint complete all as specified. 12 m&l for complete removal of existing treatment of old plastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted complete all as specified and as directed 13 dismantlingof brick work built in cement mortar including all quions arches pillars etc complete all as specified and as directed 14 m&l forbrick work with sub class b bricks straight or curved on plan exc 6m meanradius brick wallsbuilt in cm 1:6 complete all as specified and as directed 15 dismantling of wrought iron or mild steel work of any description not otherwise provided complete all as specified and as directed 16 m&l for framed work such as grils, grating etc with end of bars shoulders and or riveted or forged into spike, framed guard bars , barred iron doors, ladders framed balusters, walk ways rallings, framed work of water tanks and similar works conforming to fe 290, gde 165 complete all as specified and as directed 17 m&l for cement concrete in foundations, filling and mass concrete in 1:3:6 complete all as specified and as directed 18 m&l for preparation new steel treated or untreated surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and as directed 19 m&l for 16 18mm thick dholpur stone cladding gang saw cut with machine cut edges, uniform colour of each stone size exceeding 0.25 sqm area and not exceeding 0.5 sqm fixed with and including one number ss clamps ( grade 202 ) of flat30mm x 2mm, 150mm long made to shape in each slab, making v groove at top and bottom of stone and drilling hole for hold fastener, polishing, rubbing & including silicon treatment complete all as specified and as directed 20 s&f in repair precast cement concrete louvres and jallies, type b0, 1:2:4 u ( sing 12.5mm garded stone aggregate ) set in cm 1:4 including pillars for finshing at regular interval complete all as specified and as directed ( pre cast frame shall be measured separately and paid for under respective item ) 21 demolition of stone slabs and tiles of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar complete all as specified and as directed 22 m&l for machine pressed precast concrete interlocking paver block of approved shape and size confirming to is 15658 2006 of 60mm thickness, m 35 grade, with grey cement and pigment laid over and including 25mm thick sand cushion complete all as specified and directed 23 m&l for pre cast cement concrete block masonry with solid blocks, exc 10 cm in width and setting in mortar complete type 1:2:4 set in cement mortar complete all as specified and directed 24 m&l for 75mm thick cement concrete type d 2, 1:4:8 complete all as specified and directed 25 m&l for chequered cement concrete tiles 20cmx20cmx25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and no pigment over and incl 15 mm screed in 1:6 complete all as specified and directed 26 taking down chowkhats or framesexc. 1.50sqm each but n exc 4 sqm with shutter ( without taking of shutter from the frame ) complete all as specified and directed 27 m&l for anodised aluminium frame for doors, window, ventilators with one or more rebates including joining cleat for fixing etc. ccomplete all as specified and directed 28 s&f 2nd class hard wood plain, solid, straight chowkhats and frame, wrought, framed rebated on the solid, rounded or chamferd put together with glue pinned at joints complete all as specified and directed 29 m&l for 2nd class hard wood 35mm glazed and skelton shutter open rebated and prepared to receive glass, gauge etc. ( without sash bars ) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc. complete all as specified and directed 30 s&f plain framed panelled shutters 2nd class 30mm thick ( any numbers of panel ) with panel of timber flat on both sides ( feather edged or of veneered particle board medium density, wood particle board with commercial faces veneers, and fixed to chowkhat complete all as specified and directed 31 s&f 30 mm thick preliminated particle board interior grade prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with screwed to timber frame work as in shelves in kitchen, almirah, cup boards complete all as specified and directed. 32 s&f solidpvc door frame of size 50mmx47mm made out of 5mm plain colour pvc sheet reinforced with ms square tube all as specified and approved. 33 s&f factory made solid panel pvc door shutter withms square tube30mm thick ( style ) consisting of frame made out of ms tubes for top and bottom rails ms frame shall be covered with heat moulded plain colour pvc sheet stirip of 20mm width stuck inside with solvent cement for stiles and plain colour pvc sheets for top, lock and bottom rail on either side & as gap insert for top rail & bottom rail .panelling of plain colourpvc sheet to be fitted in the ms frame welded / sealed to the stiles and rails with suitable pvc sheet beading and joined together with solvent cement & fix in the frame at site complete all as specified and directed 34 s&f butt hinges stainless steel with screw fixed of 100mm size complete all as specified and directed 35 s&f aluminium anodised barrel tower bolt of extruded section of 150mm complete all as specified and directed 36 s&f aluminium handles cast type anodised of 150mm complete all as specified and directed 37 taking down or up, 15 mmboregalvanisedsteel tubing and connections including cleaning for refixing or removalcomplete all as specified and directed. 38 s&fgi tubing medium grade with all fitting and fixedto walls & ceilings or laid in floors, bore of pipe 15mmcomplete all as specified and directed. 39 taking down or up, 20 mmboregalvanisedsteel tubing and connections including cleaning for refixing or removalcomplete all as specified and directed. 40 s&fgi tubing medium grade with all fitting and fixedto walls & ceilings or laid in floors, bore of pipe 20mmcomplete all as specified and directed. 41 m&l for cutting chases, pinning in making good to facing where requried and pointing in cement mortar 1:3 to ends or edge of landings, steps, cills, sunshade, shelves, lintel etc. tubes or concealed conduit etc. and making good, cutting not exc 10 cm girth complete all as specified and directed. 42 s&f in repair 1000 litre capacity rotational moulded polyethylene water storage tanks ( cylindrical vertical with closed top ) hoisted and fixed in position complete all as specified and directed. 43 s&f in repair 500 litre capacity rotational moulded polyethylene water storage tanks ( cylindrical vertical with closed top ) hoisted and fixed in position complete all as specified and directed. 44 s&f in repair 15mm ball valve high pressure of ptmt with epoxy coated almn rod and high density plastic ball screwed for iron pipe and fixedfixed complete all as specified and directed. 45 disconnecting existing tanks, capacity 500 ltr setting aside ( or lowering if required ) for repair and cleaning etc. and hoisting if required, cleaning and removing all scale and dirt, from tanks and from mouth of curculating pipe and reconnecting and re fixing in position complete all as specified and directed. 46 disconnecting existing tanks, capccity 1000 ltr setting aside ( or lowering if required ) for repair and cleaning etc. and hoisting if required , cleaning and removing all scale and dirt, from tanks and from mouth of curculating pipe and reconnecting and re fixing in position complete all as specified and directed. 47 taking down existing roof treatment complete including pcc and properly clean the surface to remove loose particles with wire brushes and removing the debris out side of mod land complete all as specified and directed. 48 m&l for screed plaster 15 mm thick in cm 1:4 on roof surface complete and finished the surface even and smooth without using extra cement etc. complete all as specified and directed 49 m&l for 3 mm thick ( min ) layer of app based polymeric membrane, weighing not less than 3.5 kg / m2 reinforced with polyster non woven fabric ( weighing not less than 150 gms / sqm ) . the surface shall be painted with one coat of polymeric primer @ 0.40 kg per sqm, conforming to is: 3384 before laying of membrabe. side over laps shall be 75mm and the end lap shall be 100mm and all over laps and joints shall be sealed by torch application.for parapets, membrane shall be taken to a height of minimum 60cm and then inserted inside the parapet groove all as per manufacturer instructions andapplying one coat of bitumen @ 1.2 kg / sqm on app membrane. the top layer shall be painted with two coats ofaluminium paint complete all as specified and directed. ( the work shall be carried out by authorised applicator ) 50 m&l for 25 mm thick cement concrete type b 0, 1:2:4 ( 12.5 mm graded stone aggregates ) on roof surface complete all as specified and directed 51 dismantlingexisting terrazo dado / flooring or tilles in bath, wc and kitchen etc. complete all as specified and directed 52 m and l for vitrified ceramic tiles 9 10mm thick ( square / rectamgular ) polished, area of each tiles exc. 0.36 sqm but n exc 0.42 sqm in floorsset and jointed in neat cement slurry and pointed incoloured cement to match the floor laid over & including 15mm thick screed in cement mortar 1:6 complete all as specified and directed 53 all as per item no. 52above but on vertical surface over & including 10 mm thick rendering in cm ( 1:4 ) complete all as specified and directed 54 m&l for coloured non skid ceramic tiles 300mm x 300mm x 7mm thick in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match over & including 15mm thick screed bed in cm 1:6 complete all as specified and directed 55 m and l for coloured glazed ceramic tiles350mm x450mm x7mm thickset and jointed in neat cement slurry and pointed in coloured cement to match the flooras on vertical surfaces laid over & including 10mm thick cement screed in 1:4 complete all as specified and directed 56 hacking out old broken glass ( any thickness, size, quality or description ) fromwooden frame or stone concrete or brick surrounds glazed with putty or fixed with beads complete all as specified and directed 57 m and l for sheet glass 3mm thick ordinary quality and glazing with oil putty in square not exc.0.5sqm in each pane complete all as specified and directed 58 s&f wire netting of stainless steel wire 1.4 mm dia fixed with tinned tack of stainless steel wire steple size of mess 12 mm complete all as specified and directed 59 s&fpvc valve less, symphonic action type, flushing cistern, low level white with inlet, ball valve, float and handle including brackets 10litres complete 60 s&f pvc connection 15mm size with brass nuts and spanner of length 600mm complete all as specified and directed ( make kubix prime series jaquar / equivalent in kohler as approved by ge ) 61 s&f cast iron floor trap 75mm incl. cp grating and removing of old trap any type and shape complete all as specified 62 s&f angle cock ( spiro ) 15 mm dia cp complete all as specified and directed ( make kubix prime series jaquar / equivalent in kohler as approved by ge ) 63 s&f concealed stop cock with flange 15 mm dia cp complete all as specified and directed ( make kubix prime series jaquar / equivalent in kohler as approved by ge ) 64 s&f floor door stopper of brass body and tongue, anodised, with hard drawn steel spring, fixed in floor; overall length of cover plate 150mm complete all as specified and directed 65 s&f brass handle cast type, polished bright any size and any shape complete all as specified and directed 66 s&f brass sliding door bolts 250 mm long with sand or die cast brass hasp, steple ( bolt type ) and fixing bolt with rolled or drwan brass bolts and fixed complete all as specified and directed 67 dimantling pipes of any description fixed to wall or laid under floor complete all as specified and directed 68 s&f pvc ( swr ) single socketed in any length with rubber ring joint fixed with wall, floor of 75mm with suitable ss clamp complete all as specified and directed 69 s&f pvc ( swr ) single socketed in any length with rubber ring joint fixed with wall, floor of 110mm with suitable ss clapm complete all as specified and directed 70 s&f one piece closet with integrated cistern, seat cover and twin flushing fittings ewc complete all as specified and directed ( make kubix prime series jaquar / equivalent in kohler as approved by ge ) 71 s&f concealed cistern in wall with top push know suitable for all type wall hung wc complete all as specified and directed ( make kubix prime series jaquar / equivalent in kohler as approved by ge ) 72 s&f art basin most popular counter top wash hand basin complete all as specified and directed ( make kubix prime series jaquar / equivalent in kohler as approved by ge ) 73 s&f 200 mm square rain shower with cp arm 150 mm long complete all as specified and directed ( make kubix prime series jaquar / equivalent in kohler as approved by ge ) 74 s&f hand shower abs multi flow with 1.5 mtr s.s flexible tube & hooks complete all as specified and directed ( make kubix prime series jaquar / equivalent in kohler as approved by ge ) 75 s&f health faucet with 1 mtr s.s tubes and hooks complete all as specified and directed ( make kubix prime series jaquar / equivalent in kohler as approved by ge ) 76 s&f sink mixer with regular spout 15 mm bore dia complete all as specified and directed ( make kubix prime series jaquar / equivalent in kohler as approved by ge ) 77 s&f wall mixer with l bend for overhead shower 15 mm bore dia complete all as specified and directed ( make kubix prime series jaquar / equivalent in kohler as approved by ge ) 78 s&f single lever basin mixer w / o pop up waste system 15 mm bore dia complete all as specified and directed ( make kubix prime series jaquar / equivalent in kohler as approved by ge ) 79 s&f glass shelf 300 mm with brass screw all as specified and directed. ( make kubix prime series jaquar / equivalent in kohler as approved by ge ) 80 s&f corner glass shelf 200 mm size with brass screw complete all as specified and directed ( make kubix prime series jaquar / equivalent in kohler as approved by ge ) 81 s&f looking mirror double arm wall mounted reversible plain / magnifying ( x3 ) pivotal mirror with brass screw complete all as specified and directed ( make kubix prime series jaquar / equivalent in kohler as approved by ge ) 82 s&f looking mirror 600mm x 450 mm with frame and s s clamp suitable size complete all as specified and directed ( make kubix prime series jaquar / equivalent in kohler as approved by ge ) 83 s&f grab bar 300 mm long stainless steel with fixing brass screw complete all as specified and directed ( make kubix prime series jaquar / equivalent in kohler as approved by ge ) 84 s&f soap dish stainless steel with fixing brass screw complete all as specified and directed ( make kubix prime series jaquar / equivalent in kohler as approved by ge ) 85 s&f toilet paper holder stainless steel with suitable fixing arrangements complete all as specified and directed ( make kubix prime series jaquar / equivalent in kohler as approved by ge ) 86 s&f tumbler holder stainless steel with suitable fixing arrangements complete all as specified and directed ( make kubix prime series jaquar / equivalent in kohler as approved by ge ) 87 s&f towel rack stainless steel with suitable fixing arrangements complete all as specified and directed ( make kubix prime series jaquar / equivalent in kohler as approved by ge ) 88 s&f towel rail stainless steel with suitable fixing arrangements complete all as specified and directed ( make kubix prime series jaquar / equivalent in kohler as approved by ge ) 89 s&f towel ring stainless steel with suitable fixing arrangements complete all as specified and directed ( make kubix prime series jaquar / equivalent in kohler as approved by ge ) 90 s&f bib cock with flange 15 mm bore stainless steel with suitable fixing arrangements complete all as specified and directed ( make kubix prime series jaquar / equivalent in kohler as approved by ge ) 91 s&f granite 19 mm thick of any type work table rubbed and polised in steps, jambs, pillars, window cill, cooking plateforms and like in cement mortar 1:4 including pointing cement mortar 1:2 using marble dust with admixure of pigments to match with shade of granite complete all as specified and directed 92 s&f rough cast wired glass, 6.4 mm thick and glazing with oil putty in square size exc 0.50 sqm but n exc 0.75 sqm with solar control film 25 micron reflactive type to glass panes as per instruction manufacturer complete all as specified and directed 93 s&f sinks with drainage board made of stainless steel1.00mm thick sheet for kitchen with plug washerwaste pipe, mild steel bracketsconnecting unionover all size 915 x 460mm with bowl size 410mm x330mm x160mm but fixed in repair incl removing existing vitreous china sink with fittings complete all as specified and directed 94 supply and fixing newfrp cable tray of follwing sizes perforated type for laying pvc / xlpe cable in trecnch / at wall / under the floor including all connecting aceesories as required complete all as specified and directed ( a ) 100mmx 50mmx 3mm size 95 all as per item no. 94 above butsize 200mmx 50mmx 3mm 96 m&l for submain wiring alongwith earth continuity conductor with pvc insulated frls multistranded copper conductor cable ( phase red, neutral black, earth green ) drawing into andincluding concealed rigid non metallic pvc conduit, medium grade, isi marked ivory colour along with accessories of following nominal sizes: ( a ) 2x4 sqmm + 1x4 sqmm earth wire in 20 mm dia conduit. 97 ( b ) 2x6 sqmm + 1x6 sqmm earth wire in 25 mm dia conduit. 98 ( b ) 2x10 sqmm + 1x10 sqmm earth wire in 50 mm dia conduit. 99 ( a ) 4x4 sqmm + 1x4 sqmm earth wire in 50 mm dia conduit. 100 ( b ) 4x6 sqmm + 1x6 sqmm earth wire in 50 mm dia conduit. 101 ( b ) 4x10 sqmm + 1x10 sqmm earth wire in 50 mm dia conduit. 102 taking down carefully sub main wiring with pvc casing capping / pvc surface conduit and making good disturbed surfaces complete. 103 m& for rewiring of buzzer system of cap upto 12 modulewith 1.5 sqmm including cutting, jointing as required for desired logic of buzzer system including testing and commissioning ofelectric circuitas required 104 s&f in repair 20 amp, single pole and neutral, socket outlet, with 2 pole and earth, metal enclosed plug top in power coated crca steel sheet enclosure recess mounted with chained metal cover for the socket outlet with and including one number single pole c series mcb 16 amp as required. make legrand cat ref no 507811 & 408592 or equivalent in hager or schneider as approved by ge 105 s&f in repair mcb distribution board, powder coated, crca steel sheet, degree of protection ip 43 ik 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with following ratings & ways: spn, 240 volts, 4 ways. make legrand cat ref no 507610 or equivalent in schneider or hager as approved by ge 106 spn, 240 volts, 12 ways. make legrand cat ref no 507612 or equivalent in schneider or hager as approved. 107 supply and laying cable xlpe insulated screened pvc bedded, galvanized steel strip or wire armoured, electric power cable ( heavy duty ) 1100 volts grade with stranded aluminium conductor of following sizes : ( a ) 16sqmm4 core, 1.1 kv 108 ( b ) 25 sqmm4 core, 1.1 kv 109 m&l for cable jointing kit for upto 1.1 kv ( earthed ) grade cable for indoorheat shrink type joint complete with jointing material and accessories suitable for 3.5 core xlpe armoured aluminium conductor cable of following size : ( a ) 16 sqmm 4 core 110 ( b ) 25 sqmm 4 core 111 supply and fixing mccb 125 amp, 4 pole, 16 ka ( ics=100% icu ) thermally adjustable between 70% to 100% with spreader links on both sides as per legrand cat ref no. 420016 or equivalent in schneider or hager as approved by ge 112 supply and fixing mccb 160 amp, 4 pole, 16 ka ( ics=100% icu ) thermally adjustable between 70% to 100% with spreader links on both sides as per legrand cat ref no. 420017 or equivalent inschneider or hager as approved by ge 113 supply and fixingmccb 63 amp, 4 pole, icu 16 ka ( ics=100% icu ) , electronic release and adjustable between 40% to 100% with spreader links on both sides as per legrand cat ref no. 420013 or equivalent in schneider or hager as approved by ge 114 m&l for supplying, installation, testing & commissioningoutdoorbus bar chamber pedestal type suitable for 415v, 3 phase, 4 wire 50 hz, ac supply systemfabricated in compartmentalized design from stainless steel sheet ( ss 316 ) 2.0 mm thick totally enclosed, dust, weather & vermin proof duly painted and consisting with tpn copper bus bars of rating 1.5 times that of controlling mccb supported on f class smc insulatorswith 4 outgoing and one mccb tpn250 amp, 25 ka rupturing capacity and one 16 amp socket test point controlled by switchincluding necessary fixed in pcc 1:3:6 using 20 mm graded stone aggregate including danger plate etc including taking down old complete all as directed 115 m&l for supplying, installation, testing & commissioningoutdoorbus bar chamber pedestal type suitable for 415v, 3 phase, 4 wire 50 hz, ac supply systemfabricated in compartmentalized design from stainless steel sheet ( ss 316 ) 2.0 mm thick totally enclosed, dust, weather & vermin proof duly painted and consisting with tpn copper bus bars of rating 1.5 times that of controlling mccb supported on f class smc insulatorswith 4 outgoing and one mccb tpn100 amp, 25 ka rupturing capacity and one 16 amp socket test point controlled by switch including necessary fixed in pcc 1:3:6 using 20 mm graded stone aggregate including danger plate etc including taking down old complete all as directed 116 m&l for pipe in pipe chemical earthing with gi pipe electrode 3.0 m long having outer pipe dia 80 mm & inner pipe dia 50 mm duly filled with highly conductive and anti corrosivecompound of required quantity having chemical composition bentonite 40%, copper sulphate 20%, gypsom 5%, graphite 10%, alum 5%, zinc sulphate 10%, aluminium sulphate 10% burried in ground by digging a bore of 150 mm dia surrounded by soil friendly backfill compound non soluble in water including connection with galvanised earth strip 32 x 6 mm, making pcc pit of size 0.3 m x 0.3 m x 0.3 m ( inner size ) in mix 1:3:6 type c1 with rcc 1:2:4type b 1, 40 mm thick cover reinforced with 8 mm dia ms bars 3 nos both ways with lifting hook made out of 8 mm dia bar and testing on completion to achieve value not more than 2.0 ohm complete. ( note gi strip size 32x6 mm upto 7.5 m included in the item ) . 117 s&f in repair mcb distribution board, tripple pole and neutral ( vtpn ) powder coated crca steel sheetsuitable for mccb incomer upto 160 amp, 4 way, 415 volts, degree of protection ip 43 ik 09 with reversible double door, recess mounted, having 250 amp insulated tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required. make legrand cat ref no 507745 or equivalent in schneider or hager as approved by ge. note for mcbs & mcb dbs: mccbs, mcbs & mcb dbs shall be of the same make. 118 s&f mcbs ofc series having breaking capacity 10 ka, isi marked including required wiring connections with copper lugs of suitable size provided in mcb dbs of following ratings: ( a ) single pole 6 to 32 amp. make legrand cat ref no 408587 to 408595 or equivalent in schneider or hager as approved by ge 119 ( b ) doublepole 10 to 32 amp. make legrand cat ref no 408631 to 408636 or equivalent in schneider or hager as approved by ge 120 ( c ) doublepole, 40 to 63 amp. make legrand cat ref no 408637 to 408639 or equivalent in schneider or hager as approved by ge 121 ( d ) four pole 40 to 63 amp. make legrand cat ref no 408700 to 408702 or equivalent in schneider or hager as approved by ge 122 m&l for brick work with sub class b bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 and plastering 10 mm thick in cm 1:4 and 2 coats of white / colour washing to match the surface complete. 123 s& f in repair integral led flood light 50 w 3000 k ( ww ) warm whitewith driver inside a pdc housingphilips cat part nocvp 182 led 50 w cw fg s1 psu gr or equivalent to havells / cg as approved by ge. 124 s& f in repair integral led flood light 20 w 3000 k ( ww ) warm whitewith driver inside a pdc housingphilips / havells / cg as approved by ge. 125 s& f in repair integral led fountainlight 50 w 3000 k ( ww ) warm whitewith driver inside a pdc housingphilips psu gr or equivalent to havells / cgas approved by ge. 126 supply and fixingin repair led based bollard 10 wattwith ms pipe housing with glare free pmha difuser, ip 65 hight of light 1 mtr includingmortar base and connetion wire of suitabe size complete all as directed. 127 m&l for taking out pressure pump of any capacity upto 2 hp & any make from foundation including cutting / dismantling and fixing at new location in pcc including jointing / connecting electrical connection or as directed. 128 supply and fixing cover shed for pressure pump set1 mtr x 0.75 mtr including pcc for pole for fixing in foundation or all as specififedand directed. 129 supply and fixing in repairled bulb 12 watt warm white complete all as directed. 130 s&f in repair recess mounted led panel of round shaped, cap 12 w, long life 25000 burning hours including making connection complete all as directed. 131 supply and fixing of 1100 volts grade heavy duty cable pvc insulated copper conductor and over all sheathed in service connection including fixing in wall as reqiredwith twin core cables stranded conductor of size 4 sqmm complete all as directed. 132 all as per item no 120.01 but size 6 sqmm 133 all as per item no 120.01 but size 10 sqmm 134 supplying and fixing energy efficient recessed mounted led luminaire suitable for 2x2 grid ceiling with flat diffuser and lumen output of 3300 lumens having constant current electronic driver duly connected with 0.5 sqmm white colour pvc insulated & sheathed three core flexible multi stranded copper conductor cable as required. 135 m&l for taking old serviceable pvc / xlpe cable any size any makefrom wall / trench / floor and relaying same to new loaction / cable trench / floor / wall including jointing connecting complete all as directed 136 m&l for point wiring with 1100 volts grade pvc insulated frls multistranded copper conductor cable 1.5 sqmm ( phase red, neutral black ) and earth continuity conductor 1.5 sqmm ( green ) drawn into and including concealed rigid non metallic pvc condiut medium grade not less than 20mmdia isi marked ivory colour with all conduit fittings / fixing accessories and unwelded sunken galvanised pressed steel terminal boxes of thickness not less than 1.0 mm or mounting modular cover plate & frame for mounting switches, scokets, fan regulators as required for one light point controlled by one switch including taking down of old complete all as directed 137 all as per item no. 123 here in before but one fan point controlled by one switch. 138 all as per item no. 123 here in before but one socket outlet 6 amp controlled by one switch on the same board with other switches. 139 all as per item no. 123 here in before but one socket outlet 6 amp controlled by one switch on indepdendent board. 140 m&l for point wiring with 1100 volts grade pvc insulated frls multistranded copper conductor cable 4.0sqmm ( phase red, neutral black ) and earth continuity conductor 4.0 sqmm ( green ) drawninto existing concealed conduit andterminated in and including modular metal flush boxes for mounting modular cover plate & frame for one socket point 16 amps controlled by one switchincluding taking down of old complete all as directed 141 s&fmodular switch one way 6 amp 1 module all as per legrand britzy cat ref no. 673401 or equivalent as approved by ge. 142 supplying and fixingmodular socket6 2 / 3 pin combined 2 moduleall as per legrand mylinc cat ref no. 675555 or equivalent as approved by ge. 143 supplying and fixing modular switch one way 16 amp 1 module all as per legrand mylinc cat ref no. 675511 or equivalent as approved by ge. 144 s&f modular socket 6 / 16 amps, 2 / 3pin combined 2 module ac 230 volts. 145 s&f modular fan regulator 120 watts, 2 module ac 230 volts. 146 m&l for replacement of copper tubes of size 1 / 4 and 3 / 8 suitable for any type and capacity air conditioner complete all as specified and directed. 147 m&l for replacement of pvc insulated sheathed flexible round, 3 core cable with copper conductor of size 80 / 0.20 for ac complete all as specified and directed. 148 m&l for replacement of sheet metal enclosure, single pole & neutral with two pin & earth plug and socket with one mcb single pole 20 amp, 240 volts complete. 149 m&l for replacement of damaged insulation of size 1 / 4&3 / 8, 1 / 2&5 / 8for split ac complete as per existing site complete all as specified and directed. 150 m&l for replacement of voltage stabilizer 04 kva to 5 kva, input voltage range 90 volt to 220 volt and output voltage 220 volt to 230 volt ac + 2% variationof voltage complete with accessories etc complete all as specified and directed. 151 m&l in repair mounting frame / stand suitable for outdoor unit of split ac of any size all as specified and directed. 152 schedule of credit...

Central Organisation Railway Electrification - Rajasthan

35375607 supply of come along clamp for earth wire anti creep wire suitable for 19 / 2.5 mm galvanised steel conductoroverall dia 12.5 mm capacity 04 ton with load test certificate from govt. approved lab. ( drawing nore / el / umb / ohe / sk / 17 or power / 749 ) make pec, im, hitronics, hmh, modern energy, sdee, sst, international engineering....

Indian Army - Rajasthan

35190820 bids are invited for s and f fr is pvc insulated copper conductor, single core cable in surface recessed as required of size 2x4.00 sqmm 1x4.00 sqmm earth wire, in pvc conduit , s and f fr is pvc insulated copper conductor, single core cable in surface recessed as required of size 2x6.00 sqmm 1x6.00 sqmm earth wire, in pvc conduit , s and f , single pole and netural enclosure with a two pin and earth plug and socket complete with one single pole mcb 20 amp , supply and install split ac complete 3 star rating 2 ton , supply and install split ac complete 3 star rating 1.5 ton total quantity : 564...

Ajmer Vidyut Vitran Nigam Limited - Rajasthan

34946387 e tender for insulated rabbit conductor earthing set rod type 11 kv xlpe cables, lt pvc armoured cable, 33 kv strain insulators, 11 kv strain insulators, ct pt set, fabricated steel items, 33 kv lighting arrestor, lt power capacitors, lt power armoured cable, fabricated steel item, d/p set, fabricated steel items, ms nut and bolts, rate contract for supply of pre printed continuous computer stationary. rate contract for printing of stationary without paper and allied works, isolating switches, pin insulator, pins. rate contract for repairing of three phase distribution transformers, gi stay set, gi stay wire, earth wire, transformer oil, lt tv meter static, 33 kv xlpe cables, tong tester, ht tv meters static c type, semi automatic meter testing bench for 3 phase meter etc....

Indian Army - Rajasthan

34880939 bids are invited for s and f fr is pvc insulated copper conductor, single core cable in surface recessed as required of size 2x4.00 sqmm 1x4.00 sqmm earth wire, in pvc conduit , s and f fr is pvc insulated copper conductor, single core cable in surface recessed as required of size 2x6.00 sqmm 1x6.00 sqmm earth wire, in pvc conduit , s and f , single pole and netural enclosure with a two pin and earth plug and socket complete with one single pole mcb 20 amp , supply and install split ac complete 3 star rating 2 ton , supply and install split ac complete 3 star rating 1.5 ton total quantity : 564...

Ministry Of Railways - Rajasthan

34779143 bids are invited for come along clamp for catenary wire please refer item no 1 of table in para 13 of boq condition of contract for item specification , come along clamp for contact wire please refer item no 2 of table in para 13 of boq condition of contract for item specification , come along clamp for feeder wire please refer item no 3 of table in para 13 of boq condition of contract for item specification , come along clamp for earth wire please refer item no 4 of table in para 13 of boq condition of contract for item specification , d schackles set of one each please refer item no 5 of table in para 13 of boq condition of contract for item specification , single sleeve pulley block groove steel please refer item no 6 of table in para 13 of boq condition of contract for item specification , single sleeve pulley blockgroove fibre please refer item no 7 of table in para 13 of boq condition of contract for item specification , single sleeve pulley blockgroove steel please refer item no 8 of table in para 13 of boq condition of contract for item specification , contact wire twist cum bender 6 inch please refer item no 9 of table in para 13 of boq condition of contract for item specification , steel sling with eye each end 19mm dia and 1m long please refer item no 10 of table in para 13 of boq condition of contract for item specification , steel sling with eye each end 19mm dia and 2 mtr long. please refer item no 11 of table in para 13 of boq condition of contract for item specification , steel sling with eye each end 19mm dia and 3 mtr long please refer item no 12 of table in para 13 of boq condition of contract for item specification , steel sling with eye each end 19mm dia and 4 mtr long please refer item no 13 of table in para 13 of boq condition of contract for item specification , steel sling with eye each end 19mm dia and 10 mtr long please refer item no 14 of table in para 13 of boq condition of contract for item specification , ra...

Ministry Of Railways - Rajasthan

34676155 bids are invited for come along clamp for catenary wire please refer item no 1 of table in para 13 of boq condition of contract for item specification , come along clamp for contact wire please refer item no 2 of table in para 13 of boq condition of contract for item specification , come along clamp for feeder wire please refer item no 3 of table in para 13 of boq condition of contract for item specification , come along clamp for earth wire please refer item no 4 of table in para 13 of boq condition of contract for item specification , d schackles set of one each please refer item no 5 of table in para 13 of boq condition of contract for item specification , single sleeve pulley block groove steel please refer item no 6 of table in para 13 of boq condition of contract for item specification , single sleeve pulley blockgroove fibre please refer item no 7 of table in para 13 of boq condition of contract for item specification , single sleeve pulley blockgroove steel please refer item no 8 of table in para 13 of boq condition of contract for item specification , contact wire twist cum bender 6 inch please refer item no 9 of table in para 13 of boq condition of contract for item specification , steel sling with eye each end 19mm dia and 1m long please refer item no 10 of table in para 13 of boq condition of contract for item specification , steel sling with eye each end 19mm dia and 2 mtr long. please refer item no 11 of table in para 13 of boq condition of contract for item specification , steel sling with eye each end 19mm dia and 3 mtr long please refer item no 12 of table in para 13 of boq condition of contract for item specification , steel sling with eye each end 19mm dia and 4 mtr long please refer item no 13 of table in para 13 of boq condition of contract for item specification , steel sling with eye each end 19mm dia and 10 mtr long please refer item no 14 of table in para 13 of boq condition of contract for item specification , ra...

Local Self Government Department - Rajasthan

34579171 bids are invited for led street light aerial bunchedcable , gi bracket , shackle insulator , cross arm , led street light , gi stay set , suspension clamp , dead end clamp , lt connector type a b , cu flex wire , timer panel , earth wire strip , gel earthing total quantity : 27206...