Military Engineer Services - Rajasthan

40896071 tender for provision of certain sanctioned works in zone b under ge banar; 1 surface excavation not exc. 30 cm deep and averaging 15cm deep and getting out in soft / loose soil complete all as specified. 2 excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation etc or for shafts, wells, cesspits, manholes, pier holes, etc n exc 10 sqm on plan and n exc 1.5m in depth and getting out any type of soil complete all as specified. 3 excavating in post holes ( or similar holes ) each n exc 0.5 cum, getting out, returing, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm watering and removing surplus soil to a distance n exc 50m and making and removing surplus soil to a distance n exc 50m and making good surface in hard / dense soil complete all as specified. 4 returning, filling in, including spreading, levelling, watering and wellramming in layers not exc 25cm in soft / loose soil complete all as specified. 5 removing excavated material n.exc. 50 m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified. 6 m&l cement concrete 1:4:8 type d2 ( 40mm graded stone aggregate ) in foundations, filling and mass concrete complete all as specified. 7 all as per ser item no 6.00 but pcc 1:3:6, type c2. 8 use & waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits ( if any ) of foundation and plinth beams; and similar work; vertical or to batter flat and rough finished surfaces of concrete complete all as specified. 9 use & waste formwork to edges of concrete flats, treads breaks in floors, window cills, concrete rallings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of rcc / pcc bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20 cm wide and rough finished surfaces of concrete complete all as specified. 10 use & waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick ( horizontal or sloping ) flat and rough finished surfaces of concrete complete all as specified. 11 m&l forrcc ( design mix ) m 25, using 20 mm graded stone aggregate in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete complete all as specified. 12 m&l forrcc ( design mix ) m 25, using 20 mm graded stone aggregate in beams, cantilevers, bressumers, lintels over 1.5m span complete all as specified. 13 m&l forprecast 1:2:4 rcc, using 20 mm graded stone aggregate in cover slab complete all as specified. 14 m&l forrcc ( design mix ) m 25, using 20 mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified. 15 m&l mild steel tmtbarsin reinforcement 10mm dia and overcut to length bent to shape required including crankingbindingspirally, hooping for columns hooking ends and binding with and including mild steel wire ( annealed ) not less than 0.9mm dia complete all as specified. 16 m&l mild steel tmt barsin reinforcement5mm dia and over up to 10mm dia in stirups andcut to length bent to shape required including crankingbindingspirally, hooping for columns hooking ends and binding with and including mild steel wire ( annealed ) not less than 0.9mm dia complete all as specified. 17 m&l for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, modular bricks in cement mortar built in cm 1:6 complete all as specified. 18 m&l for 15mm thick rendering in cm 1:4 mixed with wpc on fair faces of brick work or concrete surfaces of wall complete all as specified.note: wpc shall be measured and paid separately. 19 material and labour for preparation of newly plastered surface of walls and applying two coats of cement base paint over one coat of alkali resistance primer complete all as specified. 20 m&l for integral water proofing compound in external plastering complete all as specified. 21 m&l for preparation of newly plastered or unplastered surfaces of and applying three coats of white wash complete all as specified. 22 all as per ser item no 21.00 but on wall ceiling. 23 m&l for 100 mm thick cement concrete for sub base type d2, 1:4;8 ( using 40 mm graded aggregate ) complete all as specified. 24 m&l 25 mm thick cement concrete for sub base b 1, 1:2:4 ( 20mm graded aggregate ) complete all as specified. 25 m&l for non skid ceramic colour tiles ( 300 x 300 mm ) x 7 mm thick in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15mm thick bedding of cm 1:4 layer in floor finishes complete all as specified. 26 m&l for coloured glazed ceramic tiles in vertical surface 350x250x7mm / 450x350x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles in vertical surface including 10mm thick renderingin cm 1:4 complete all as specified. 27 m&l for hardcore of gauge n exc. 63mm ( broken stone or boulders ) , deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified. 28 m&l 75 mm thick pcc ( 1:3:6 ) type c1 ( by using 20mm aggregate ) in plinth protection and similar work complete all as specified. 29 s&f 125 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified. 30 s&f 100 mm long extruded aluminium alloy handles, fabricated type., anodised complete all as specified. 31 m&l solid pvc door frame of size 50mm x 47mm made out of 5mm plain colour pvc sheet reinforced with m.s square tube, supplying & fixing in opening as per specification complete all as specified. 32 m&l factory made solid panel of pvc door shutter 30mm thick ( style ) consisting of frame made out of m.s. tubes for top & bottom rails, m.s. frame shall be covered with heat moulded plain colour pvc `c channel heaving a pvc sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour pvc sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour pvc sheet to be fitted in the m.s frame wedded / sealed to the stiles, & rails with suitable pvc sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified. 33 s&f 100 mm long butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type b 21 complete all as specified. 34 s&f steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified. 35 s&f sheet glass 4 mm thick, figured glass, pin headed type and glazing with oil putty or wooden beads supplied with shutters in square n.exc 0.5 sqm in each pane complete all as specified. 36 m&l two coats of synthetic enamel paint over a red oxide primer including prepration of newly treated steel surfaces of girth exc 10cm complete all as specified. 37 all as per ser item no 36.00 but n.exc 10 cm width or girth. 38 s&f 15mm dia galvanized steel tubing, medium grade, with all fitting and fixed complete to walls celling or laid in floors complete all as specified. 39 s&f 20mm dia galvanized steel tubing, medium grade, with all fitting and fixed complete to walls celling or laid in floors complete all as specified. 40 all as per ser item no 39.00 but 25 mm bore. 41 m&l for vitreous china wash basin, white, flat back, size 550x400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified. 42 m&l for vitreous china squatting pan, `orissa pattern, size 580 x440 mm white, with integral foot rests ( excluding flushing cistern and flush pipe ) complete all as specified. 43 m&l for pvc valveless, syphonic action type, flushing cistern, 10 ltr capacity, low level, white, with inlet, ball valve, float and handle including brackets and including flushing pipe 32 mm dia of bore, high density polyethylene pipes of pressure rating 6 kg / sqcm complete all as specified. 44 s&f pvc connections 15mm size with ptmt nuts of length 450mm complete all as specified. 45 m&l for 15mm dia of bore cast copper alloy stop valves, fancy type, chromium plated, screwed pressure, with crutch of butterfly handle, screwed both ends for iron pipe for unions and fixed complete all as specified. 46 s&f 15mm pillar taps, cast copper alloy, with capstand heads, chromium plated, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed to 15 mm size pipe complete all as specified. 47 s&f pvc waste pipe 32mm dia for whb complete all as specified. 48 s&f 15mm dia bib tap cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified. 49 m&l for 110mm pvc ( swr ) pipes, single socketed, in any length, with rubber rings joints, laid in trenches or in floors complete all as specified. 50 m&l for 75mm pvc ( swr ) pipes, single socketed, in any length, with rubber rings joints, fixed to walls complete all as specified. 51 m&l for 75mm dia of bore pvc ( swr ) floor trap plain with grating including jointing with solvent cement complete all as specified. 52 m&l for 110mm pvc ( swr ) bends any radius complete all as specified. 53 all as per ser item no 52.00 but 75 mm. 54 m&l for 75mm dia pvc ( swr ) vent cowl complete all as specified. 55 s&f 110mm pvc ( swr ) p trap complete all as specified. 56 m&l 110 mm pvc ( swr ) branch piece, single ( y ) equal or unequal complete all as specified. 57 cutting of bituminous / pcc / pqc road for laying of pipe line not exceeding 1.5 m depth / width inculding making good to distributed portion to match with existing road / path with pcc complete all as specified. 58 m&l 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick ac building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified. 59 s&f 500 litre capacity rotational moulded polyethylene water storage tanks ( cylinderical vertical with closed top ) hoisted and fixed in position all as specified in ssr part i including 20mm brass ball valve high pressure complete all as specified. 60 material and labour for square rubble walling jodhpur type regular course well bonded bedded and solidly hearted built in cement mortar ( 1:6 ) complete all as specified. 61 extra over on stone walling for hammer dressing to face stone with maximum depression on face from straight edge n.exc 20mm and dressing faces beds and joints as specified to square rubble walling regular course jodhpur type complete all as specified. 62 m&l for structural steel in roof trusses ( framed ) trussed, purlins, crane gantries, rails and fastening and heavy bracket framing ( beam, tee, angle, channel or flat sections ) including distance pieces, columns, cleats etc ) 63 s&f rolled sections as in fencing post or similar work fe 410w ( gde e 250 ) quality a complete all as specified. 64 s&f pre painted galvalume aluminium zinc coating gi based corrugated steel sheet 0.50mm of an colour having tensile strenght of 550 mpa as in roof covering / cladding to wall fixed with self tapping screws complete all as specified. 65 s&f pre painted galvalume aluminium zinc coating gi based plain steel sheet 0.50mm of an colour having tensile strenght of 550 mpa as in roof covering / cladding to wall fixed with self tapping screws complete all as specified. 66 mild steel screw bolts ( machine made ) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut n exc 15 cm long dia of shank 11 to 15 mm complete all as specified. 67 m&l for sand filling under floor including watering and consolidation 25 mm thick complete all as specified. 68 m&l for glossy finished machine pressed precast concrete interlocking paver block any shape and size conforming to is 15658 2006 of 60 mm thickness m 35 grade with white cement glossiness in pigments and laid in position / patterncomplete all as specified. 69 m&l for pre cast concrete block as in kerb stone ( machine made ) with solid blocks type b1, 1:2:4 ( 20mm graded stone aggregate ) exc 10 cm in width and setting in cement mortar 1:4 complete all as specified. 70 pcc ( 1:4:8 ) type d2 using40mm graded crushed stone aggregatein concretebedding to drain pipes, including packing under and haunching against the sidesof pipes after they are laid and tested complete for 150mm bore pipe complete all as specified. 71 m&l reinforced concrete pipes 150mm bore, class np 2, laid and jointed complete all as specified. 72 m&l precast cement concrete block masonary with solid block of ( 1:4:8 ) type d2 exc 10 cmin width & setting in cm ( 1:6 ) complete all as specified. 73 m&l cement concrete ( 1:2:4 ) type b1 using 20 mm graded crushed stone aggregate in surface channels or drains and benching including finishing the top of benchingeven and smooth using extra cement complete all as specified. 74 extrafor formingfairfinisheddrain orchannel 30cminner girth in cementconcreteusing extracementincluding forms, moulds, mitred / stoppedends etc complete all as specified. 75 add to srl item no. 74.00 above for each 25mm girth or part thereofover 30cm. 76 m&l rendering 5 mm thick in cement mortar 1:3 on caling / roof projection / chajja complete all as specified. 77 m&l for pcc 1:2:4 type b 1 as in coping incl necessary form work complete all as specified. 78 m&l for keyed pointing in cm 1:3 to squared rubble, coursed or uncoursed stone masonary complete all as specified. 79 m&l for rendering screed bed or bedding layer of mortar 10 mm thick in cm 1:3 as in floor / roof to be finished smooth without using extra cement mixed with water proofing compound as per manufacturer instruction complete all as specified. 80 m&l for moorum / red bajri filling in floors or pavings, spreading and levelling in layers and well ramming including watering as required complete all as specified. 81 s&f viterous china bowl urinal flat back, size 465x355x265 mm white ( minimum ) , with grating and union for discharge pipe ( excluding flushing cistern, flush pipe and waste pipe ) complete all as specified. 82 s&f viterous china urinal partition white of size 310x700 mm complete all as specified. 83 m&l for urinal spreader of ptmt any colour for fixing with 15 mm dia pipe ( minimum weight 60 gms ) complete all as specified. 84 s&f for 32 mm bore waste coupling of ptmt ( half full threaded ) ( minimum weight 32 45 gms / 40 60 gms ) complete all as specified. 85 cutting into existing manholes for connecting new drains ( internal dia of pipe 150 mm ) making good to pipe and rendering, cutting out existing benching for and forming branch channel ( 1 / 2 round or 3 / 4 section ) in cement concrete 1:2:4 type b 1 smooth finished and reforming benching complete all as specified. 86 m&l for providing polythene film, black, 200 micron laid in floors complete all as specified. 87 m&l for cement concrete work in pavement / hardstanding of flexural strength, 40 kg / per square centimeter in field using 400 kg of cement per cubic meter thickness of concrete upto 20 cm complete all as specified. 88 m&l for finishing surfaces with brooming complete all as specified. 89 m&l for forming contraction ( dummy ) joints 65mm deep x 10mm wide and filled with sealing compound grade a complete all as specified. 90 m&l plain cement concrete 1:2:4 type b 1 using 20 mm graded stone aggregate asin cast in situ in lintels up to 1.5 m span, cills and other similar bands, plinth courses, parapets, copings, bed plates and the like including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work complete all as specified. 91 supply only ms galvanized chain link fencing of size 100mmx100mm square mesh of 10 gauge type complete all as specified. 92 fixing only chain link fencingincluding line wires, any mesh, size andy type of standards, rails, straining bolts etc. complete including provision of binding wire complete all as specified. 93 m&l galvanized, 2 strand, steel barbed wire, 2.24 mm dia barbed with 2 mm dia barbs at 75 mmspacing and straining and fixing to any type of standard rails, straining boltsincluding securing or tying atcrossing with and provision of galvanized ms wire staples or steel pins etc ( each line wire to be measured ) complete all as specified. 94 m&l for point wiring of one light point controlled by one, one way switch complete with any length using approved colour coding as per is, with stranded copper conductor 1.5 sq.mm ( nominal area ) , single core, pvc insulated and unsheathed stranded frlscable 1100 volts grade, isi 694 marked, in pvc rigid conduits heavy duty isi marked totally concealed in wall / floor / roof including all accessories etc. with sunken boxes suitable for mounting switches / sockets etc. and pvc insulated stranded copper conductor 1.5 sq.mm single core cable as earth and connecting to common earth dolly complete all as specified for the following: note ( i ) cutting in chases and pointing in will be done by contractor without any cost. ( ii ) making good of distrubed surfaces matching with existing finishes will be done by contractor without any extra cost. 95 one 5 pin 5 amp socket outlet point on same board with other switches including earth wire. 96 s & f piano flush type switch 5 amps single pole all as specified. 97 s & f multipurpose socket outlet with piano flush type 3 pin 5 amps all as specified. 98 s&f ceiling rose surface type three terminalscomplete all as specified. 99 s & f led lights fitting 1x 20w, 220v, ac decorative box type with driver, holder including led tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified. 100 supply and fixing earthing complete with gi earth plate eletrode 60 cm x 60 cm x 6.0 mm thick barried directly in ground vertically to a depth note less than 2.25 metres below ground level with top edge of earth plae at a depth note less than 1.5 metres below level ground, connected to gi iron or steel earth wire 4 mm dia ( 8 swg ) by means of nuts , bolts checks nuts, washers andearth wire protected by gi iron pipe 15 mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in pcc ( 1:3:6 ) type c1, pre cast rcc coverslab 30cmx30cmx10cm with one lifting handle made of 8mm dia ms bar funnel wire mesh, 20mm bore gi or steel pipe medium grade for watering, charcoal or coke and salt in alternate larges, necessary excavatin and earth work in any type of soil complete all as shown electrical plate no 3 of mes schedule part i and testing after completion. 101 s&f mcb spn db 4 way, double door, with 200 amp rated busbar 240 v, complete all as specified. 102 supply and fixing mcb sp 6 32 amp 240 volts. 10 k complete all as specified. 103 mcb spn32 amp 240volt c series 10ka complete all as specified. 104 s & f led lights fitting 1x 10w, 220v, ac decorative / mirror type type with driver, holder including led tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. 105 drilling ofwater pipe line of any type and size upto 50 mm size for connection of 25 / 20 mm gi pipe with clamp and other assesries complete all as specified. 106 supply and fixing 20 mm bore gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe, non rising forged brass spindle class i and fixed with required necessary gi fittings complete all as specified. 107 all as per ser item no 105.00 but 15 mm. 108 all as per ser item no 105.00 but 25 mm. 109 m&l for clean, dry sand in trenches / ducts for cushioning to cable complete all as specified. 110 supplying and laying pcc cable cover, flat, class lv, type 2 of size 300mm x 180mm x 40mm complete all as specified. 111 supply laying and testing cable xlpe insulated, screened, pvc bedded galvanised steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with standed allumiuium conductor of size 10 sqmm 2 core complete all as specified. 112 supply and lay galvanised medium grade including fitting 40 mm dia with all fittings laid in trenches / floor complete all as specified. 113 supply and fix heavy duty metal bodyexhaust fan 300 mm sweep, including louvers, grounting with nut bolts complete all as specified. 114 s & f led security lightluminaries 35 watt complete with all accessories andwall mounting bracket of suitable size including clamps, nut bolts etc. prewired complete all as specified....

Military Engineer Services - Rajasthan

40896054 tender for special repair / replacement of water pipe line at af stn phalodi; 1 excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 sqm on plan and n exc 1.5 m in depth & getting out, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes or for layingunderground cable, pipe lines etc. in soft / loose soil, complete all as specified and directed. 2 returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in soft / loose or hard dence soil complete all as specified and directed. 3 removing excavated surplus material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. 4 taking up or down 80 mm bore steel water tubing and connections including all fittings and removing unserviceable pipe from site complete all as specified and directed.note : excavation and earth work shall be measured and paid separately. 5 taking up or down 50 mm bore steel water tubing and connections including all fittings and removing unserviceable pipe from site complete all as specified and directed.note : excavation and earth work shall be measured and paid separately. 6 taking up or down 25 mm bore steel water tubing and connections including all fittings and removing unserviceable pipe from site complete all as specified and directed.note : excavation and earth work shall be measured and paid separately. 7 supply, laying, jointing and testing in trenches 80 mm bore steel water tubing, galvanized, medium grade, with all fittings such as bends, tees, union etc., complete all as specified and directed. 8 supply, laying, jointing and testing in trenches 50 mm bore steel water tubing, galvanized, medium grade, with all fittings such as bends, tees, union etc., complete all as specified and directed. 9 supply, laying, jointing and testing in trenches 25 mm bore steel water tubing, galvanized, medium grade, with all fittings such as bends, tees, union etc., complete all as specified and directed. 10 supply & fixing in repair for gun metal, globe or gate valves size 50 mm bore , with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 11 supply & fixing in repair for gun metal, globe or gate valves size 25 mm bore , with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 12 supply, installation, connecting and testing of 80 mm bore sluice valve, class pn 1.6 flanged ends, with ci body, wheel and brass spindle and nuts etc, non rising type is 14846:2000 marked including jointing materials i.e. rubber gaskets, nuts, bolts etc. including takind down old sluice valve complete all as specified and directed. 13 material & labour for construction of valve pit chamber in stone masonry built in cm ( 1:6 ) of size 1200mm x 1200mm x1200mm ( internal dimension ) with precast cement concrete block of pcc ( 1:4:8 ) type d 2 using 40mm graded stone aggregate and 15mm thick rendering in cm ( 1:6 ) on internal and exposed external surfaces including 50 x 50 x 6 mm mild steel angle iron frame and 3.15mm thick ms sheet cover with locking arrangement and 1no. 50mm size 4 lever lock with triplicate keys including painting to steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide primer including demolition of old valve pit chember complete all as specified and directed. 14 material & labour for passing of water supply pipe line through road / pavementrailway / hardstanding or any other situation by adopting manual method of for 80mm dia pipe complete all as specified and directed....

Indian Army - Rajasthan

40848606 bids are invited for boq bid motor hi speed for cooler duct plant , 10mm wiring for cooler duct plant , cock wall set for cooler duct plant , mcb box with 3 poll for cooler duct plant , mcb motor repair , cooler pvc pipe fitting , rccb 3poll 440 watt , electric light pipe pvc , labour charges , honey pad total quantity : 852...

Indian Army - Rajasthan

40836395 bids are invited for pin board with labour charge size 3x6 inch , pin board with labour charge size 8x4 inch , wooden rack for base light , wooden cover box for ac waring 2x15 , floor carpet size 17x17 in map veh with labour , alluminium blade pasting and mtsc work with labour , allmira shifiting it cell pin board cloth charge with labour , file rackgodrej locker , window cutting and repair sunmica property , sunmica sheet total quantity : 364...

North Western Railway - Rajasthan

40823000 supply of inverter based mig mag synergic pulse welding plant with air cooled torch 400 amp including design, supply, installation, testing, commissioning and proving of machine comprising of power source, wire feed unit, function panel and other concomitant accessories. the machine would also cover comprehensive preventive maintenance, during the warranty period which will be inclusive of all spares, material and labour cost. all spares and material except consumables shall form part of the scope of the preventive maintenance during the warranty. details may be referred at clause 3 of section iv of annexure techncial specifications appended with the tender [ warranty period: 30 months after the date of delivery ] , concomitant accessories of inverter based mig mag synergic pulse welding plant as per clause 3.2 of section iv of annexure technical specification appended with this tender.bidders are required to attach the price break up of these accessories in pdf file along with submitted bid [ warranty period: 30 months after the date of delivery ] , consumable spare of inverter based mig mag synergic pulse welding plant as per clause 6.0 of section v of technical specification appended with this tender. consumables shall be supplied along with the machine or as per agreed time table for each consignee.bidders are required to attach the price break up of these accessories in pdf file along with submitted bid , optional accessories of inverter based mig mag synergic pulse welding plant as per clause 3.3 of section iv of annexure technical specification appended with this tender. the price of optional accessories indicated in clause 3.3 indicated has to be quoted by firm . the bidder may also include any other accessories which which can improve the productivity, performance, reliability, efficiency, or enhance the capability of the machine as a whole bidders are required to attach the price break up of these accessories in pdf file along with submitted bid [ warranty period: 30 months after the date of delivery ] , supply of inverter based mig mag synergic pulse welding plant with air cooled torch 400 amp including design, supply, installation, testing, commissioning and proving of machine comprising of power source, wire feed unit, function panel and other concomitant accessories. the machine would also cover comprehensive preventive maintenance, during the warranty period which will be inclusive of all spares, material and labour cost. all spares and material except consumables shall form part of the scope of the preventive maintenance during the warranty. details may be referred at clause 3 of section iv of annexure techncial specifications appended with the tender [ warranty period: 30 months after the date of delivery ] , concomitant accessories of inverter based mig mag synergic pulse welding plant as per clause 3.2 of section iv of annexure technical specification appended with this tender.bidders are required to attach the price break up of these accessories in pdf file along with submitted bid [ warranty period: 30 months after the date of delivery ] , consumable spare of inverter based mig mag synergic pulse welding plant as per clause 6.0 of section v of technical specification appended with this tender. consumables shall be supplied along with the machine or as per agreed time table for each consignee.bidders are required to attach the price break up of these accessories in pdf file along with submitted bid , optional accessories of inverter based mig mag synergic pulse welding plant as per clause 3.3 of section iv of annexure technical specification appended with this tender. the price of optional accessories indicated in clause 3.3 indicated has to be quoted by firm . the bidder may also include any other accessories which which can improve the productivity, performance, reliability, efficiency, or enhance the capability of the machine as a whole bidders are required to attach the price break up of these accessories in pdf file along with submitted bid [ warranty period: 30 months after the date of delivery ] page 2 of 7 run date / time: 27 / 11 / 2023 13:39:54stores / north western rly tender document...

North Western Railway - Rajasthan

40822927 supply of inverter based mig mag synergic pulse welding plant, supply of inverter based mig mag synergic pulse welding plant with air cooled torch 400 amp including design, supply, installation, testing, commissioning and proving of machine comprising of power source, wire feed unit, function panel and other concomitant accessories. the machine would also cover comprehensive preventive maintenance, during the warranty period which will be inclusive of all spares, material and labour cost. all spares and material except consumables shall form part of the scope of the preventive maintenance during the warranty. details may be referred at clause 3 of section iv of annexure techncial specifications appended with the tender [ warranty period: 30 months after the date of delivery ] , consumable spare of inverter based mig mag synergic pulse welding plant as per clause 6.0 of section v of technical specification appended with this tender. consumables shall be supplied along with the machine or as per agreed time table for each consignee.bidders are required to attach the price break up of these accessories in pdf file along with submitted bid , concomitant accessories of inverter based mig mag synergic pulse welding plant as per clause 3.2 of section iv of annexure technical specification appended with this tender.bidders are required to attach the price break up of these accessories in pdf file along with submitted bid [ warranty period: 30 months after the date of delivery ] , optional accessories of inverter based mig mag synergic pulse welding plant as per clause 3.3 of section iv of annexure technical specification appended with this tender. the price of optional accessories indicated in clause 3.3 indicated has to be quoted by firm . the bidder may also include any other accessories which which can improve the productivity, performance, reliability, efficiency, or enhance the capability of the machine as a whole bidders are required to attach the price break up of these accessories in pdf file along with submitted bid [ warranty period: 30 months after the date of delivery ] , supply of inverter based mig mag synergic pulse welding plant with air cooled torch 400 amp including design, supply, installation, testing, commissioning and proving of machine comprising of power source, wire feed unit, function panel and other concomitant accessories. the machine would also cover comprehensive preventive maintenance, during the warranty period which will be inclusive of all spares, material and labour cost. all spares and material except consumables shall form part of the scope of the preventive maintenance during the warranty. details may be referred at clause 3 of section iv of annexure techncial specifications appended with the tender [ warranty period: 30 months after the date of delivery ] , consumable spare of inverter based mig mag synergic pulse welding plant as per clause 6.0 of section v of technical specification appended with this tender. consumables shall be supplied along with the machine or as per agreed time table for each consignee.bidders are required to attach the price break up of these accessories in pdf file along with submitted bid , concomitant accessories of inverter based mig mag synergic pulse welding plant as per clause 3.2 of section iv of annexure technical specification appended with this tender.bidders are required to attach the price break up of these accessories in pdf file along with submitted bid [ warranty period: 30 months after the date of delivery ] , optional accessories of inverter based mig mag synergic pulse welding plant as per clause 3.3 of section iv of annexure technical specification appended with this tender. the price of optional accessories indicated in clause 3.3 indicated has to be quoted by firm . the bidder may also include any other accessories which which can improve the productivity, performance, reliability, efficiency, or enhance the capability of the machine as a whole bidders are required to attach the price break up of these accessories in pdf file along with submitted bid [ warranty period: 30 months after the date of delivery ] ...

Indian Army - Rajasthan

40820035 bids are invited for boq bid 10mm 3 layer wiring , cock wall set pvc of duct plant , mcb box with 3 pole mcb , mcb motor repair , cooler motor repair , cock wall set pvc of new cooler , elctric light pipe , labour charges , rccb 3 pole , honey pad , honey pad cooler for duct plant total quantity : 867...

Indian Army - Rajasthan

40817551 bids are invited for material labour for repair replacement of ryb and neutral leads and testing up to the entire satisfaction of engineer in charge complete all as specified and directed , m l for replacement of 0.35 ohm cmos 1.65v to 3.6v spdt switch 2.1 mux for clamp meter creative tools ct pcm0208 as directed. , m l for replacement of 28v, 200ma low noise linear regulator suitable for electric meter creative tools ctpcm0208 as directed. , m l for replacement of 20v 200ma low noise linear regulator suitable for electric meter creative tools ct pcm0208 as directed. , m l for replacement of low capacitance charge injection 15v 12vicmos spdt in sot 23 suitable for electric meter creative tools ct pcm0208 , m l for replacement of 15v 2.5a synchronous buck boost dc convertor suitable for electric meter creative tools ct pcm0208 as directed , m l for replacement of power supply suitable for electric meter creative tools ct pcm0208 as directed. total quantity : 7...

Department of School Education - Rajasthan

40784135 bids are invited for manpower outsourcing services minimum wage unskilled; others; mazdoor / labour , manpower outsourcing services minimum wage unskilled; admin; watch and ward , manpower outsourcing services minimum wage unskilled; others; sweeper , manpower outsourcing services minimum wage unskilled; others; female warden total quantity :...

Military Engineer Services - Rajasthan

40783159 servicing / maintenance / repair of external water supply lines and allied works at mh jodhpur and ce office complex andservicing / maintenance / repairing of internal / external electrification, summer / winter appliances and allied works at dad complex jodhpur under ge ( army ) no 2 jodhpur; 1 taking up / down old di / gi tubing connection of 20mm bore including clearing ( from trenches / wall / roof ) complete all as spsecified and as directed. 2 all as per item no 01 above but for 25mm bore 3 all as per item no 01 above but for 40mm bore 4 all as per item no 01 above but for 50mm bore 5 all as per item no 01 above but for80mm bore 6 all as per item no 01 above but for 100mm bore 7 all as per item no 01 above but for150mm bore 8 supply and laying for 20 mm bore galvanised steel tubing medium grade with all fittings and fixtures laid in trench or ceiling or laying in floors complete all as spsecified and as directed. 9 all as per item no 2 above but 25 mm dia bore. 10 all as per item no 2 above but 40 mm dia bore. 11 all as per item no 2 above but 50 mm dia bore. 12 all as per item no 2 above but 80 mm dia bore. 13 all as per item no 2 above but 100 mm dia bore. 14 material and labour di pipes of size 100mm dia with spigot and socket end centrifugally cast class k 9 , in any length laid in trenches / on surface / over masonary pillar and connection to old or new position complete all as spsecified and as directed.. 15 material and labour di pipes of size 150mm dia with spigot and socket end centrifugally cast class k 9 , in any length laid in trenches / on surface / over masonary pillar and connection to old or new position complete all as spsecified and as directed.. 16 taking up / down old unserviceable gate valve / ball valve of size 20 / 25 / 40 / 50 mm bore complete all as spsecified and as directed. 17 supply and fix gun metalgatevalve heavy duly isi marked with iron wheel head screwed both ends for iron pipes 20 / 25 mm bore dia complete all as spsecified and as directed. 18 all as per item no 11 above but 40 mm size. 19 all as per item no 11 above but 50 mm size. 20 taking up old unserviceable / defective cast iron non return valveand sluice valve flanged type of any make 80 to 150 mm bore dia complete all as spsecified and as directed. 21 supply and fix 80 mm dia bore cast iron non return valve flanged type heavy duty conforming to is with rubber gasket joints including bolts, nuts, etc complete all as spsecified and as directed. 22 all as per item no 15 above but 50 mm dia bore. 23 supply and fix cast iron sluice valve of size 150 mm dia flanged of class pn 1.6 confirming to is with rubber gasket joints bolts nuts etc complete all as spsecified and as directed. 24 all as per item no 17 above but sluice valve of size 100 mm dia. 25 all as per item no 17 above but sluice valve of size 80 mm dia. 26 supply and fix in repairs cast ironfoot valve with leather flap scaling clamped on cast iron disc plates of size 100 mm dia complete all as spsecified and as directed. 27 all as per item no 20 above but 80 mm dia. 28 taking down carefully spindle of cast iron sluice valve of size 80mm boredismantling parts and reassembling by replacement of newbrass spindle suitable for 80mm dia sluice valve, class pn 1.0, and refixing in original position including provision of nuts, bolts, washers, rubbers gaskets etc complete all as spsecified and as directed. 29 m&l for replacement of pressure gauge to read in is / bsunit type 0 to 10 kg / cm2 and 0 to 150 psi including taking down old one complete all as spsecified and as directed. 30 m&l for painting of sluice valve / nrv upto 80mm dia as per existing colour complete all as spsecified and as directed. 31 m&l for painting of valve chambar plaster portion with cement base and steel portion with synthetic enamel paint of any size complete all as spsecified and as directed. 32 s&f in replacement ci butterfly valve 80 mm dia with lever operated ci disc nitrile / epdm rubber lining test pressure pn 1.6 and ms nut bolt and washers and pair of rubber / fibers required for the work will be supplied by contractor for fixing in position complete all as directed. 33 all as per item no 26 above but 100 mm dia 34 all as per item no 26 above but 150 mm dia 35 m&lfor ruber gas ket joint / tyton jointfor ci / di pipe of size 80 mm bore complete all as spsecified and as directed. 36 m&lfor ruber gas ket joint / tyton jointfor ci / di pipe of size 100 mm bore complete all as spsecified and as directed. 37 m&lfor ruber gas ket joint / tyton jointfor ci / di pipe upto size 150 mm bore complete all as spsecified and as directed. 38 m&l for construction of valve chembers with ms cover 3 mm thick of valve pit of size 1200x1200x1200 mm ( internal dimensions ) including necessary excavation, earth work 150 mm thickpcc 1:4:8 type d2 as in foundation, pcc 1:2:4 type b1 in coping plastering 15 mm thick in cm 1:4, and angle iron frame4ox40x6 mm and locking arrangement including painting with two coat of synthetic enameled paint over a coat of redoxide primer after preparation of surface complete all as spsecified and as directed. 39 m&l for construction of valve chembers with ms cover 3 mm thick of valve pit of size 900x900x900 mm ( internal dimensions ) including necessary excavation, earth work 150 mm thickpcc 1:4:8 type d2 as in foundation, pcc 1:2:4 type b1 in coping plastering 15 mm thick in cm 1:4, and angle iron frame4ox40x6 mm and locking arrangement including painting with two coat of synthetic enameled paint over a coat of redoxide primer after preparation of surface complete all as specified and directed 40 m&l for construction of valve chembers with ms cover 3 mm thick of valve pit of size 600x600x600 mm ( internal dimensions ) including necessary excavation, earth work 150 mm thickpcc 1:4:8 type d2 as in foundation, pcc 1:2:4 type b1 in coping plastering 15 mm thick in cm 1:4, and angle iron frame40x40x6 mm and locking arrangement including painting with two coat of synthetic enameled paint over a coat of redoxide primer after preparation of surface complete all as specified and directed 41 m&l p:c:c 1:2:4 type b1 ( 20 mm graded stone agg ) as in sub base 200 mm thick as per tank size including 15 mm thick cement plaster on top side of concrete surface including necessary form work for pcccomplete all as specified and directed 42 supply and fixing pvc float valve ( ball cock bady with epoxy coated aluminium rod & hd ball ) of size 15 / 20 mm dia.including all fittings and taking down unserviceable complete all as spsecified and as directed. 43 all as per item no 36 but 35 / 40 mm dia 44 excavation in trenches not exc 1.5 meter wide & not exc 1.5 mtr in depth: for foundationetc or for manholes, laying of pipe in soft and loose of soil and getting out complete all as specified and directed 45 returing filling in trenches including watering and well ramming in layer not exc 25 cm thick in soft / loose soil complete all as spsecified and as directed. 46 removing excavated material ( soil ) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point complete all as spsecified and as directed. 47 supply and fixing in replacement of battery 12 volt 180 ah maintenance free complete all as spsecified and as directed. 48 m & l for cutting the existing bituminous road / pcc road or path as per site requirment in 20 cm depth including refilling and consolidating the disturbed portion using pcc / bituminous for making good as existing surface complete all as spsecified and as directed. 49 earthing complete with galvanised steel earth plate electrode 60×60cm× 6mm thick, buried directly in ground ( earth pit not less than 2.25 metres deep below ground level ) with top edge of the plate not lessthan 1.5 metres below normal ground level, connected to galvanised iron strip 25×4mm size means of bolts, nuts, check nuts and washers of galvanised iron or steel check nuts and washers of brass including necessary earth work, pcc chamber , ci cover with frame, funnel wire mesh, earth lead protection pipe 40 mm dia, watering pipe 15 mm dia, 7.5 meter earth lead etc all as shown in electrical plate no 5 in ssr part i and connected to earth test point / lt panel / pump including testing on completion complete all as spsecified and as directed. 50 dewatering by using pump as required and , removal of mud and settled silt including scrapping of complete inner surface with the help of wire brush etc and therefore cleaning by water and bleaching of the following oh tank / ug sumps at mh jodhpur / ce ( army ) jodhpur area and apply two coat of lime wash to all internal surface of wall / bottom / ceiling and two coat of apex emulsion painting to all external surface including top surface and painting to oblitering labels shall be not less than 60x40 cm using black paint to match with existing dimension and writing particulars such as capacity of sump , date / due date of cleaning etc useing white paint . including disposal of mud silt etc obtained after cleaning up to 50 m away complete all as spsecified and as directed. : ( a ) oh tank of capacity 5000 to 10000 glns ( b ) ug sump capacity 50000 to 600000 glns 51 s&f in replacement nut, bolt, washer of different size isi marked 52 s&f in replacement gland dori of different sizesisi marked 53 supply only greaseisi marked 54 m&l for disconnecting carefully the centrifugal pump set of capacity 15 / 20 hp and rewinding of copper winding of motor with super enamelled copper wire with existing size and gauge including varnishing, heating and testing, commissioning and reconnecting all as required to the entire satisfaction complete all as spsecified and as directed. 55 m & l for repairing / overhauling ofthe following spit cage centrifugal pump set coupled with motor by replacing of unserviceable parts like bearings, sleeves bushes, bearings housing shaft, gunmetal impeller etcassembling the pump with new packing materials, nuts and bolts, washers and checking the alignment connectingup with delivery, suction pipes and testing for pump set ofpump set of 15 / 20 hp capacity complete all as specified and directed 56 all as per srl item no 49 above but for pump set of 7.5 hp capacity. 57 all as per srl item no 49 above but for pump set ofpump set of 10 hp capacity. 58 m&l for disconnecting carefully the sewage pump set of capacity 7.5 hp and rewinding of copper winding of motor with super enamelled copper wire with existing size and gauge including varnishing, heating and testing, commissioning and reconnecting all as required to the entire satisfaction complete all as specified and directed 59 m&l for disconnecting carefully the mono block pump set of capacity 5 hp to 8 hp and rewinding of copper winding of motor with super enamelled copper wire with existing size and gauge including varnishing, heating and testing, commissioning and reconnecting all as required to the entire satisfaction complete all as specified and directed 60 dismantling, removingpump set of capacity 5 hp pump set and taking out electrical connection taking for servicing of pump motor to workshop for machining, complete greasing. changing gland packing, minor parts like rubber / steel bushing, bearing , nut bolts and re fixing the same to there same position with necessary fixing arrangement complete all as specified and directednote all required t&p will be included in above quated rates. 61 all as per srl item no 56 but submersible pump set of 3 hp 62 s&f in replacement fully automatic star delta motor starter suitable for 15 hp , with single phase protectionac 3, 415v, 50 hz, 3 phase suitable for existing in panel complete all as specified and directed 63 s&f in replacement fully automatic star delta motor starter suitable for 7.5hp, with single phase protection, ac 3, 415v, 50 hz, 3 phase suitable for existing lt panel complete all as specified and directed 64 s&f in replacement fully automatic star delta motor starter suitable for 10hp, with single phase protection, ac 3, 415v, 50 hz, 3 phase suitable for existing lt panel complete all as specified and directed 65 m&l for site clearance complete all as specified and directed 66 m&l 100 mm hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed 67 m&l for pcc ( 1:4:8 ) type c 2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed 68 m&l for 80 mm thick factory made pre cast cement concrete rubber moulded laquer finish using chemical and admixure inter locking tiles having compressive strength not less than 400 kg / sqcm, of shape and colour as approved by ge , laid over and including 25mm thickcompacted approved sand cushioned surface, joints filled by fine sand and compacting the top surfaces of paver blocks after laid etc of approved make complete all as specified and directed 69 supply and fix pvc insulated submersible cable 3 core flat copper conductor ( including jointing material ) size 6 sqm 1100 volt complete all as specified and directed 70 m&l for repair of leakage of pipe line 80 to 150mm dia any size / type incl exacavation, dewatering, cleaning, repairing of pipe line leakage including all reqd items for repair at site and returning / filling and matching as per existing complete all as specified and directed. 71 m&l for repair of leakage of pipe line 20 to 50 mm dia any size / type incl exacavation, dewatering, cleaning, repairing of pipe line leakage with reqd all accessories at site and returning and matching as per existing complete all as specified and directed. 72 s&f pvc insulated 2.5 sqmm unsheathed 3 core round copper conductor stranded cable wire 1100 v grade isi marked with suitable size of pvc conduit with proper fixing on wall / piller complete all as specified and directed 73 supply and fixing in replacement of rotational moulded polyethylene water storage tanks 500 lts ( cylindrical vertical with closed top ) hoisted and fixed in position, complete all as specified and directed 74 s& f in replacement single phase preventer for 3 phase motor fixed for star delta starter complete all as specified and directed 75 s& f volt meter 0 500 volts square / round digital type incl taking down old one complete all as specified and directed 76 s& f amp meter 0 200 amps square / round digital type incl taking down old one complete all as specified and directed 77 s&f in replacement 3 pole power contactor for starter incl taking down complete all as specified and directed 78 m&l for spray painting of complete water pumpset of cap 7.5 hp to 20 hp with two coats of synthetic enameled paint of specified colour after preparation of surface and writing letters and numbers complete all as specified and directed 79 s&f bib taps of 20mm dia bore, cast copper alloy with clutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specifed and directed 80 m&l for cross arms, bracings, supports, clamps, angle iron, flats and back plates febricated from ms structural steel sections including nuts, bolts and washers of suitable sizes including welding, bending ( cold or hot ) , drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminum paint over one coat of red oxide primer complete all as specified and directed 81 dismantling, 500 lph reverse osmosis plant for servicing / repair and replacement of unserviceable parts for smooth functioning of system and re fixing the same to it same position with necessary fixing arrangement of ro plant complete all as directed at site. note: servicing of ro plant will be carried out twice in one year complete all as specified and directed 82 repair / replacement of membarane for 500 lph ro plant of 250 ltr capacity complete all as directed at site. make : hydranautics, dow, aqua ( each plant having 2 nos 250 ltrs of membarane ) 83 antiscalant liquidchemicals are supplied by the contractor for dosing and cleaning of reverse osmosis plant ( ro ) in daily basis complete all as specified and directed 84 hydro chloric acid chemicals are supplied by the contractor for dosing and cleaning of reverse osmosis plant ( ro ) in daily basis complete all as specified and directed 85 micron sediment filter 20 x 4 of size chemicals are supplied by the contractor for dosing and cleaning of reverse osmosis plant ( ro ) in daily basis complete all as specified and directed 86 carbon 1100 silver id chemicals are supplied by the contractor for dosing and cleaning of reverse osmosis plant ( ro ) in daily basis complete all as specified and directed 87 multi grade media filter ( stone gravels ) are supplied by the contractor for dosing and cleaning of reverse osmosis plant ( ro ) in daily basis complete all as specified and directed 88 repair / rewinding and servicing of high pressure motor pump installed at 500 lph ro plant, including all pvc pipe lines to be checking / servicing will be done and broken parts of pvc pipe will be replaced complete all as specified and directednote : pvc pipe rates are incuded in the quoted rates. 89 dismantling, aquaguard ro water filter servicing / repair and replacement of unserviceable parts for smooth functioning of system and re fixing the same to it same position with necessary fixing arrangement complete all as directed at site. note: 1.servicing of aquaguard ro will be carried out twice in one year as per directed 2.rates shall be included for sediment filter 90 taking down carefully alluminium / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switchs, sockets, aluminium conductor cable with and incl wooden batten or fr pvc conduit and its accessories such as wooden gutties, rawl plugs, gi screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor / ceiling etc as original i.e. brick work, plastering, white washing, obd etc as required, complete all as specified and directed. 91 taking down carefully unsv main switch and dbs including mcbs of any size make, type and capacity omplete all as specified and directed. 92 m&l for point wiring ( concealed modular ) complete for one light point / fan point / exhaust fan point / bell point controlled by one 1 way switch / bell push, with 1.5 sq mm ( nominal area ) frls pvc insulated un sheathed and stranded copper conductor cable isi marked and pvc concealed conduit isi marked of size 20 mm dia medium grade and pvc conduit fittings such as tees, bends, elbow, reducers with and including frls pvc insulated unsheathed 1.5 sqmm copper earth wire, connecting to common earth dolly with and incl metal flush box of suitable size for fixing modular switches / sockets etc and making good surface by wall panelling etc, complete all as directed. make of wire : kei / c&s / finolex / havells / rr kable / polycab. note : 1. the cost of modular type metal flush boxes and modular accessories like inner / outer cover plates etc is deemed to be included in quoted rate. 2.the cost of cutting chases on wall and making good surface on wall are deemed to be included in the quoted rate 93 all as per srl item no. 86 here in before but for one socket outlet 3 pin, 5 amps on independent board. 94 all as per srl item no. 86 here in before but for one socket outlet 3 pin, 5 amps on same board. 95 all as per srl item no. 83 here in before but with single core multistranded cable of size 4.0 sqmm for one 15 amp sockets outlet on independent borad and multistranded insulated copper eart continuity conductor of size 4.0 sqmm all as specified and directed by engr in charge 96 s & f in replacementmodularswitch1way 6a , 1module size complete all as directed. 97 s & f in replacementmodularswitch1way 16a , 2module size complete all as directed. 98 s & fin replacement modular bell push way 6a with 2 module size with indicator complete all as directed. 99 s & fin replacement modularsocket , 6 a , 5 pin , 2module size complete all as directed. 100 s & f in replacementmodularsocket , 6 a / 16 a , 5 pin , 2module size complete all as directed. 101 s & f in replacement of modular type fan regulator 2 module a / c 240 volts.note:make ofmodular switches / sockets and other accessories : mk ( by honeywell ) / legrand ( myrius ) / havells ( crabrtee ) 102 m&l point wiring ( concealed normal ) complete with single core frls pvc insulated, unsheathed, multi stranded copper conductor cables 1.5 sqmm 1100 volts grade, with and incl 1.5 sqmm frls pvc insulated, unsheathed, multi stranded copper conductor cables as continuous earth wire connected to metallic bodies of luminaries / fans etc at one end and to common earth dolly at other end, complete wiring drawn through & pvc casingand cappingof 25 mm and above ( as per conductor run ) medium grade, isi marked, incl all accessories & fittings / junction boxes / inspection covers etc, with and incl concealed ms sunken box of suitable size flush with wall surface, covered with & incl 3 mm thick bakelite, laminated hylem sheet / gang box for top cover suitable for fixing of piano type switches / sockets etc, complete all as specified and directed for one light / fan / bell / exhaust fan point controlled by one no, 1 way, 5 amps switch. ( note :the cost of ms sunken box with 3 mm thickbakelite, laminated hylem sheet top cover is deemed to be included in quoted rate. ) make of wire : kei / c&s / finolex / havells / rr kable / polycab 103 all as per items ser no 96 above but for one socket outlet 3 pin, 5 amps on independent board, controlled by one no 5 amp switch. 104 all as per items ser no 96 above but for one socket outlet 3 pin 5 amps on the same board controlled by one no 5 amp switch. 105 all as per srl item no. 96 here in before but with 2.5 sq mmfrls copper wire with 1.5 sqmm frls copper earth wire for indpendent 15 amp point. 106 s&f in replacement of switch piano type, single pole, one way, 5 amps, 230 volts, complete all as specified and directed. make : ssk / havells ( reo ) / gold medal 107 s&fin replacement of socket, two in one, 5 pin, 5 amp, universal type, 230 volts, complete all as specified and directed. make : ssk / havells ( reo ) / gold medal 108 s&fin replacement of switch piano type, single pole, one way, 15 amps, 230 volts, complete all s specified and directed. make : ssk / havells ( reo ) / gold medal 109 s&fin replacement of socket, 6 pin, 5 / 15amp, multipurpose shutter type, 230 volts, complete all as specified and directed. make : ssk / havells ( reo ) / gold medal 110 s&f in replacement of resistance type fan regulator a / c 240 volts. make : gold medal / havells ( reo ) / ssk 111 s&fin replacement of bell push, flush type 5 amps, 230 volts. make : ssk / havells ( reo ) / gold medal 112 s&fin replacement of electric call bell ding dong ac 230 volts single pole.make : gold medal / havells / crompton 113 s&f of modular ceiling rose, two to three terminals, bakelite body, 230 volts, complete all as specified and directed.make : havells / ssk / gold medal 114 s&fin replacement of lamp holder, metal cased, bakelite body, 230 volts, with 9w led lamp complete all as specified and directed. make : ssk / havells ( reo ) / gold medal 115 supply and fixing led light fitting mirror type with ligh out put diffuser 2 feet, 10 watt 220 v ac decorative type with driver holder and led lamp including connecting up with three core flexible copper conductor cable of suitable size complete 116 supply and fixing led lights fitting 1x 18w, 220v, ac decorative box type with driver, holder including led tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete 117 supply and fixing led emergency batten lights fitting 10 watt, 220v ac with high quality polycarbonate and translucent serrated milky white diffuser to get glare free, smooth light distribution , thermoplastic / aluminium housing enhances safety and luminaire is pre wired with high efficiency electronic driver and led lamp, power backup of 3 to 4 hr including up with three core flexible copper conductor cable suitable size complete all as specified and directed. 118 supply and fixing led emergency batten lights fitting 20 watt, 220v ac with high quality polycarbonate and translucent serrated milky white diffuser to get glare free, smooth light distribution , thermoplastic / aluminium housing enhances safety and luminaire is pre wired with high efficiency electronic driver and led lamp, power backup of 3 to 4 hr including up with three core flexible copper conductor cable suitable size complete all as specified and directed. 119 s&f of plastic ventilating fan 200 mm sweep plastic body including louvers with cutting chases on brick wall and grounting with nut bolts on aluminium frame complete all as specified and directed. make : crompton / havells / orient note : rates are deemed to be included for cutting chasing on wall or window, grouting with nut bolts etc 120 s&f of exhaust fan 300 mm sweep steel body including louvers with cutting chases on brick wall and grounting with nut bolts on aluminium frame complete all as specified and directed. make : crompton / havells / orient note : rates are deemed to be included for cutting chasing on wall or window, grouting with nut bolts etc 121 s&f of distribution board, double door, made out of crca mild steel sheet surface with insulated material like polyester or with epoxy powder coating and ip 43 & ik 09 protection, spn 08 way ( concealed flush to wall ) , 240 volts with bus bar rating 200 amps, dust and vermin proof, suitable for incorporation of mcb’s and isolators etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed.make : havells / schneider elect / legrand / abb / hager 122 supply and fixing double doormanufacturer mcb db tpn 04 way flush in wall comprising of sheet metal enclosure powder coated fitted with bus bar 250 amps 415 volts. 123 s&fof mcb, c curve type, 25 ka, 63 amp to 100 amp, tpn with over load and short circuit protection, complete all as directed. make : schneider elect / legrand / abb / havells 124 supply and fixing mccb fp 125 amp, 25 ka c curve 415 volts. 125 s&fof mcb, c curve type, 10 ka, 63amp, spn with over load and short circuit protection, complete all as directed. make : schneider elect / legrand / abb / havells 126 supply and fixing in repair 240v, 10 ka c curve miniature circuit breaker ( mcb ) of single poles and current carrying capacity 5 to 32 amp, in the mcb db complete with connection. make : schneider elect / legrand / abb / havells 127 taking down old sub main wiring and m&l for concealed sub main wiring with 2 run of 16 sqmm frls, pvc insulated, unsheathed and stranded copper conductor cable with and incl 16 sqmm ( nominal area ) frls, pvc insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main db to sub main db, drawn in to separate concealed medium grade, isi marked, non metallic pvc conduit 20 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor / ceiling etc as original by brick work, plastering, white washing, obd etc as required, complete all as directed. note : tworun of 10 sq.mm. and one run of 10 sq.mm ( earth wire ) cableincuding one run of conduit pipe will be measured as one length including making good the disturbed surfaces. make of wire : finolex / havells / kei, make of pvc conduit : finolex / modi / polycab. 128 all as per srl item no. 39 here in before but with 2 run of 6.0 sq mm frls copper wire with one run 6 sqmm frls copper cable as earth wire. 129 all as per srl item no. 39 here in before but with 2 run of 4.0 sq mm frls copper wire with one run 4 sqmm frls copper cable as earth wire. 130 m&l for earthing with galvanized steel earth plate electrode of size 600 x 600 x 6 mm buried directly in ground earth pit not less than 2.25 mtr below of normal ground level with top edge of earth plate should not less than 1.5 mtr below normal ground level and connected to galvanized iron earth lead wire of size 4 mm dia by means of bolts, nuts, washers of galvanized iron or steel all as shown in electrical plate no.3 of mes ssr part i connecting to earthing test point on completion with and including 15 mm bore gi light grade protection pipe ( 7.5 mtr long ) for earth lead gi lead wire 4mm dia ( 7.5 mtr long ) , pcc pit with cover in pcc 1:2:4 type b 1 reinforced with 8 mm dia tor bars @ 80mm c / c, 20mm dia medium grade watering pipe with funnel, wire mesh, common salt, charcoal, necessary excavation and earth work, complete all as specified and directed. 131 servicing / maintenance / repair of dg set of 200kva installed at dad complex forrepair / replacment of the following components all as specified and directed by engr in charge. ( a ) checking water temperature safety control ( b ) checking and correcting impeller of water pump for excess play. ( c ) checking and correcting turbocharger, any oil leakage, tightening of mounting screws and nutsetc. ( d ) cleaning, tightening all electrical connection of engine ( e ) checking and cleaning of generator bushes ( alternator ) andcommutator ( f ) cleaning of entire engine. ( g ) checking exhaust and inlet manifold bolts and capscrew ( h ) checking engine blow by ( h1 ) cleaning of radiator inside and outside by removing and refixing after cleaning. ( j ) checking and adjusting injector and valves. ( k ) cleaning fuel inlet connections and screw, ( l ) checking of oil. ( m ) replacing of radiator hoses of different sizes with clamps ( n ) checking of vibration damper 132 ditto as above item no 43 but for 50 kva dg set note : item nos 43 & 44 : any following item required for servicing / preventive maintenance will be measured and paid separately under respective items 133 supply onlyoil filter suitable for 200 kva dg set 134 supply only oil filter suitable for 50 kva dg set 135 supply onlyk oil super suitable for 200 / 50 kva dg set 136 supply only fuel filter suitable for 200 / 50 kva dg set 137 supply only set of hose suitable for 200 kva dg set 138 supply onlyelement suitable for 200 / 50 kva dg set 139 supply only element air cleaner suitable for 200 / 50 kva dg set 140 supply only v fan belt suitable for gen set 200 / 50 kva 141 supply only coolant 142 dismantling the pt / fi pump assembly, repair / overhauling / calibrating in authorised lab including replacing tornoutrings, plunger, damper plate gasket etc. including, refixing, reconnecting, testing & commissioning complete as specified and directed. 143 taking down ceiling fan, exhaust fan, wall mounting fan, padestal fan etc of any make, type & sweep including checking the serviceabilty of ceiling fan, exhaust fan, wall mounting fan, padestal fan etc in the presence of mes representative, transporting the same to work shop and refixing the same after replacing of unserviceable parts all as directed by engr in charge.note : any unsv parts reqd for replacement shall be measured and paid separately under respective item of schedule as supply only. 144 dismantling and removing old burnt copper wire winding of ceiling fans of any size & sweep of any make and rewinding with new enameled super copper wire of existing gauge as per old copper winding incl providing insulation by varnishing ( golden ) , cleaning, oiling, greasing etc all as specified and directed by engr in charge. 145 all as per item no 48as above but for exhaust fan of any size & sweep of any make. note : for srl no 48 & 49 : the super enameled winding wire is to be provided shall be any one make of devidayal / usha / chetak of appropriate gauge as directed by engr in charge. 146 supply only capacitor for ceiling fans / exhaust fan / cabin fan / table fan ofcapacity / isi marked2.5 mfd. 147 all as per item ser no 50 above but for4.0 mfd. 148 supply only ball bearing suitable for ceiling / exhaust fans of following size complete all as specified and directed by engr in chargefor ball bearing for any type of ceiling fan. make: skf / nbc / tata 149 ball bearing for any type of exhaust fan, make: skf / nbc / tata 150 supply only ms clamps ( standard size ) with rubber real with ms nut, bolts, check nut & split pin complete. 151 supply only canopy for ceiling fans. make: usha / khaitan / crompton 152 supply only fan blade for ceiling fan of any type & size. make: usha / khaitan / crompton 153 supply only fan blade for exhaust fan of any type & size. 154 supply and fixing in repair single pole and neutral enclosure with a three pin and earth plug and socket complete with one single mcb sp 20 amps. make legrand / c&s / havells 155 supply and fix in replacement fornew heating element including rubber ring, washer, holding clamps and nuts of following capacity1.5 kw complete all as specified & directed. make : bajaj / recold 156 all as per item ser no 149 above bur for2 kw 157 supply and fix in replacement new thermostat of temperature variating ranging from 25° centigrade, suitable for 15 / 25 litre capacity geyser complete all as specified & directed.make : bajaj / recold 158 supply fix inreplacement new pvc connection ( heavy duty ) of 15 mm dia with required length with 2 nos of brass, chromium plated nuts of approved make & quality complete all as specified & directed. 159 supply and fix in replacement safety valve isi marked. 160 supply and fix in replacementpressure realizing valve fo size 15 mm dia. 161 supply and fix in replacement geyser bottom and top plate suitable for geyser of any make, size & type duly painted 25 ltrs capacity complete all as specified and directed by engr in charge. 162 supply and fix in replacement of indicator lamp assembly for geyser complete all as specifed and directed by engr in charge. 163 maintenance, servicing and testing of split type / window type ac, capacity upto 2 tons, any make, by cleaning cooling coil, condenser fins, blowing of dust from machines / air filters cleaning with viniclean solution using pressure jet system with water , checking and decarbonising all electric system oiling / greasing of blower motor, checking and removing any vibration and leakage in the equipment including checking / repair to inter locking device for winter / summer to ensuretaking down and refixing in position complete all as directed by engineer in charge.note cost of minor repair, replacement of petty items such as nuts, bolts, washers, screws, rubber mounting pads of compressor etc, transportation of equipment to workshop and back is deemed to be inclusive in the unit rates quoted by the contractor. 164 s&f, in replacement, new compressor for split type ac 1.5 / 2 ton capacity including disconnecting, opening up, taking out burnt compressor by cutting / opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after flushing the line with co2 gas to avoid trapping the water vapour ensuring leak proof system complete all as specified and directed.make: shriram / kirloskar / voltas / carrier / whirlpool 165 m&l for finding out leakage with the pressure testing of the condensor / cooling unit / compressor of window type / split type ac of 1.5 / 2 toncap including dismantling the same for recharging with r 22 gas or as per manufacturers instruction and stop leakage by brizing / soldering including charging the gas to required level and testing the ac for the entire satisfaction of eic. 166 s&fnylon type filter pad20 micron for window type ac of capacity up to 2 ton including taking out unserviceable filter pad complete all as specified and directed. 167 s&f, in replacement, running capacitor 5 mfd 230 volts for blower motor complete all as specified and directed. make : keil / asian / tesla. 168 supply and fixing in replacementstarting capacitor clip type of cap. 80 100 mfd, 440 suitable for 1.5 / 2 ton capacity window / split type ac complete all as directed by engineer in charge make kell / tesla / sharda / escop 169 s&f in replacement ofrunning capacitor, 36 / 45 / 50 mfd suitable for 1.5 / 2.0 ton capacity window / split type ac of approved make. 170 s&f in replacement ofindoor unit complete set suitable for 2.0 ton capacity make : voltas / whirlpool / blue star 171 supply and fixing in replacement, external / outdoor unit complete including compressor for split type ac 2.0 ton capacity, complete all as specified and directed 172 s&f, in replacement, starting relay suitable for split type ac of capacity up to 2 ton complete all as specified and directed. make : shriram / renutrol 173 s&f, in replacement, condensing fan motor 1 / 8 hp, single phase suitable for split type ac up to 2 ton capacity including testing complete all as specified and directed.make: khaitan or universal. 174 s&f, in replacement, power circuit breaker ( pcb ) kit for split / window type ac complete all as specified and directed. 175 supply, fixing & testing new compressor for water cooler of capacity 60 / 120 ltr, including disconnecting, opening up, taking out burnt compressor by cutting / opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after ensuring entire system leak proof complete all as specified and directed. make kirloskar, or shriram 176 s&f, in replacement, thermostat switch suitable for water cooler, any capacity / make including taking down unserviceable thermostat switch complete all as specified and directed.make: shriram or ranutroll or indofoss. 177 s&f, in replacement capillary filter driver 2 way suitable for water cooler including taking out old unserviceable capillary filter complete all as specified anddirected 178 s&f in replacement drain out pipe of split type ac complete all as directed by engineer in charge. 179 s & f single phase preventor with accessories suitable for electric motor 5 15 hp capacity with necessary electrical connection by using proper size of single core copper wire complete incl taking down / removing old u / swith necessary electrical connection complete as directed. make :minilec cat no vsp1 ast / l &t / simens 180 supply and fixing analog voltmeter 0 500volt rage of size 2.5x2.5, 3 phase, 415 voltsuitable forthe lt panel board where directed including taking out old burnt out voltmeter including electrical connection withsuitable size of copper wire complete all as directed & specified , make:l&t / ae / meco or equiv 181 supply and fixing digital ammeter 0 150 amps of size 4x4, capacity , 3 phase, 415 volt with operating voltage 210 vnos suitable forthe lt panel board where directed including taking out old burnt out ammeter including electrical connection withesuitable size of copper wire complete all as directed & specified , make:l&t / schenider / hpl , cat no pamebrita 32 or equiv 182 supply and fixing indicator assy 3 pcs per set suitable for 230 volt matching with exisisting one forthe lt panel board where directed including taking out old u / s indicator assy including electrical connection withesuitable size of copper wire complete all as directed & specified , make:ae / hpl or equiv 183 prevantivemaintenance andcleaning of filtersincluding minor replacement of defective parts of air coolerplants 06nos. electrically operatedinstalled at dad completeall as specified and directed of the following capacities note : ( i ) servicing and cleaning of all air cooling plant will be carried out one in two months as per directed by engr in charge. ( a ) air cooling plant 4500 cfm 02 nos. ( b ) air cooling plant 12000 cfm 02 nos. ( c ) air cooling plant 9000 cfm 02 nos. 184 m & l for taking down unserviceable electric motor from 3 to 7.5 hp capacity from foundation dismantling pump motor for servicing / replacement of unserviceable bearing, and rewinding of motor reassembling after repair / servicing reinstall on existing location & testing on full load complete. 185 all as per item no 188 above but capacity of pump motor 2 hp for air cooling plant 186 m & l for taking down unserviceable electric motor pump set upto 1.5 hp capacity from foundation dismantling pump motor for servicing / replacement of unserviceable bearing, gland bush and rewinding of motor reassembling after repair / servicing reinstall on existing location & testing on full load complete. 187 material & labour for taking down unserviceable mono block pump motor of 15hp capacity from foundation, dismantle the pump motor for servicing / replacement of unserviceable bearing, gland bush, and rewinding of motor, reassemble after repair / servicing reinstall on existing location & testing on full load complete after completion. 188 m&l pre air filter wire mesh for fresh airfor air cooling unit including taking down unserviceable and as per directed. 189 m&l13 mm thick nitriel rubber insulation with glass cloth and ub paint for xpose duct including taking down unserviceable as per dircted by engr in charge. 190 m&l for filter honey bee pad / filter for air cooling system installed various location at new mh as per existing including taking down unserviceable. 191 supply and fixing complete canvas clothes ( zip arrangement ) with s / s body frame of suitable size of any description as per existing and directed by engr in charge 192 taking out old lt under ground cable from trenches / floor / road / wall / pipe / pole of any size and description incl joint, complete all as specified and directed by engr in charge. 193 supply, laying and testing cable xlpe insulated , screened, pvc bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4 core 194 supply, laying and testing cable xlpe insulated , screened, pvc bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 95 sqmm 3.5core 195 excavationin trenches nexc1.5 m wideand nexc1.5m in depth and getting out in soft / disintegrated rock laying of / pipes etcas directed by by engr in charge. 196 returning, filling in soft / loose soils including spreading, levelling, watering and well rammingin layers not exceeding25 cm thick each all asdirected by engineer in charge. 197 removing surplusexcavated rock to a distancenot exc 50 manddepositing where directedat a level n.exc. 1.5 m above the starting point complete all as specified and directed. 198 supplying and layingun reinforced precast concrete cable cover, isi marked , class lt, type 1, size 250mm x 150mm x 40mmduly embossed with lt cable 1100 volts, cable size insqmm allas specified and as directed. 199 m &l for dry clean fine river sand as in sand cushioning to undeground cableincluding punning down of sand with layer of sand 8 cm thick before laying of cable and 15 cm after laying cable in trenches all as specified and directed note: punned thickness shall only be measured and paid. 200 s&f in replacement of dol starter in sheet steel enclosure type mk 1 suitable for motor 3 phase, 415 volts 5 / 7.5 hp complete all as specified and directed by engr in charge. 201 supply and fixing led street light fitting 35 watt 230 v ac outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with ip 65 / 66 protection complete 202 s&f of gi pipe of 50 mm nominal dia light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wallincluding painting with two coats of aluminium paint over a coat of red oxide paint complete all as directed. note : the cost of ms clamp, nut, bolt, washer and gi fittings etc shall be inclusive in the item rate. 203 s & f street light poles painting with two coats of aluminium paint over a coat of red oxide paint complete all as directed. 204 taking up / down old gi tubing connection including clearing ( from trenches / wall / roof ) 50 mm bore complete as directed by engr in charge 205 supply and lay 50 mm bore galvanised steel tubing medium grade with all fittings and fixtures laid in trench or ceiling or laying in floors complete all as directed. 206 supply and fix gun metalgatevalve heavy duly isi marked with iron wheel head screwed both ends for iron pipes 50 mm bore dia. 207 supply, laying, testing and commissioning of semi conducting compound conductor screened pvc bedded galvanized steel strip or wire armoured xlpe insulated heavy duty 11000 volts grade with stranded aluminium conductor of size 95 sqmm x 3 core confirming to is 7098 part ii, suitable for earthed system complete all as direcrted. make : havells / finolex / polycab / keinote : 1. the end termination joint shall be measured and paid separately under respective items.2. excavation, earth work, sand cushioning and protection cover will be measured and paid for separately. 208 supply jointing and testing outdoor type cable end termination joint ( heat shrinkable ) suitable for aluminium conductor cable of size 95 sqmm x 3 core, 11000 volts grade, complete all as directed.make : raychem / densons / m seal 209 dehydration / filtration of transformer oil of transformersof various capacities installed at dad sub station by disconnecting plants electrically for recirculation existing transformer oil and dielectric strength is up torange 40 kv to 50kv note : ( i ) test result will be recorded before & after filtration of oil. ( ii ) contractor should make his own arrangement for oil filtration plant including transportation complete. ( iii ) transformer oil for topping up will be measured and paid in relavant item as required. 210 supply andfilling transformer oil of good quality for topping up transformers 400 kva having dielectric strength not less than 50 kv , flash point not less than 135 degree c , having low viscosity for filling or replacing the old oil complete all as specified and directed by engr in charge. make servo / power oil / hp 211 supply, installing and testing 180ah, 12v maintanances free battery for dg set make: exide / amaron or equivalent 212 dismantling & taking down of air break gang operated switches vertical / horizontal mounted including insulators and operating mechanism for repair / replacement of broken / worn out components and insulators etc. 213 supply & install 11 kv 3 phase gang operated air break switch with drop out fuses set ( consisting 12 nos post insulator ) 400 amp capacity, vertical mounting with fixed and moving contacts complete with locking arrangement and fixing the gang operated switch on existing two / four pole structure including making all jumper connections with insulated leads of suitable size with line tops etc, all as specifed and directed.make jaipuria / rashtriya / petco 214 dismantling & taking down insulator any type any size from ht pole. 215 m&l for preparing old painted steel or iron surfaces of lt panel of any size and description by cleaning dirt, oil, grease etc, removing the old paint, rust by scratching with wire brush / emery paper etc, with and incl repairing / refixing of existing panel doors with hinges, by using of gas welding or fixing new panel door of same size and shape made of 2.0 mm thick steel sheel, as per site requirement, with and incl all kind of machine work i.e. cutting, bending, pressing, threading, welding, jointing etc, after disconnecting lt electric connection and apply two coat of synthetic enamel paint over one coat of red oxide primer etc and making all electric connections and testing the same, complete all as specified and directed by engr in charge. 216 s&f in repairs 3 pole power contactor 1no+2nc as per sample of makel & t, m / s havells / siemens / standara / legrandall as specified and directed. 217 s&f, in replacement, mccb, 415 volts, 04 pole, 630 amps, 50 ka, ics = 100% icu, with thermal magnetic release, including spreader terminals, phase barriers, complete all as specified and directed by engr in charge. make : schneider / l&t / c&s / indo asian / havells 218 s&f, in replacement, mccb, 415 volts, 04 pole, 400 amps, 36 ka, ics = 100% icu, with thermal magnetic release, including spreader terminals, phase barriers, complete all as specified and directed by engr in charge. make : schneider / l&t / c&s / indo asian / havells 219 s&f, in replacement, mccb, 415 volts, 04 pole, 250 amps, 36 ka, ics = 100% icu, with thermal magnetic release, including spreader terminals, phase barriers, complete all as specified and directed by engr in charge. make : schneider / l&t / c&s / indo asian / havells 220 supply and fixing security light termination box, weather proof, along with connector for 3 phases and mcb sp 6 amps incl 4 aluminium strip bus bar mounted on insulator of size 200x250x150mm. make : sintex / hensel...

Indian Army - Rajasthan

40777293 bids are invited for repair to motor cycle transporting mcycle hero honda from mt yard ge a jaisalmer to civil work , repair and servicing of break system clutch system carburetor and adjusting the same and assemble complete incl tes , replacement of spark plug all as specified , replacement of engine oil 1 ltr , greasing of both wheel bearings and chain assemby after cleaning of us grease , replacement of head light bulbs as directed 1 set , removing of fuel tank from mcycle cleaning and drying before fixing , check the battery connections and wiring cleaning of bty terminal with mineral , repair of break system and replacement of break shoe , labour charge total quantity : 11...

Indian Army - Rajasthan

40777134 bids are invited for repair of motor cycle mse servicing of vehicle including water servicing with replacement , replacement of spark plug all as specified , replacement of engine oil ltr , greasing of both wheel bearings and chain assemby after cleaning of us grease , removing of fuel tank from mcycle cleaning and drying before fixing , check the battery connections and wiring, cleaning of bty terminal , repair of break system and replacement of break shoe , labour charge total quantity : 8...

Indian Army - Rajasthan

40752543 bids are invited for rod trolley for mbt arjun repair of air conditioner involving compressor gas filling and including labour charges , welding cable copper 3 mm , temple cable 1 mm , welding rod 250 mm x 350 mm , trolley grease gun carrier for mbt arjun heavy duty repair of ac welding cable temple cable welding total quantity : 14...

Department of School Education - Rajasthan

40747568 bids are invited for manpower outsourcing services minimum wage unskilled; others; mazdoor / labour , manpower outsourcing services minimum wage unskilled; others; sweeper , manpower outsourcing services minimum wage unskilled; admin; watch and ward , manpower outsourcing services minimum wage unskilled; others; female matron total quantity :...

Archaeological Survey Of India - Rajasthan

40729745 tender for special repair to laxmi narain temple at ranthambhore fort distt. swaimadhopur ( complete work ) ; 1 description of items and specification ofwork to be excuted. 2 provision for making the working space around the laxminarayan templeby cutting & uprooting the rank root vegetation i.e , grassthorny bushes & shurbs etc. & removal of rubbish from the complex lead up200 mts etc complete. 3 removal / taking out the dead weathered / cracked / damaged plaster of thickness 25 30mm average thick very carefully & disposal of the unserviceable materiallead up to 100 mtr etc complete. 4 removal / taking out the dead / cracked / damaged lime concrete from floor & roof portion and disposal of the unserviceable material lead up to 100 mtr etc complete 5 replastering of 25 to 30mm average thick lime surkhi plaster in 1:1:1 ( 1 lime : 1 surkhi :1 coarse sand ) in two coats mixed with traditional binding / adheshive material i.e. gud, belgiri and babool gum including cleaning the surface and racking out joints as per original texture and curing etc complete in all respect. 6 replaster for making mahrabs, arches, pillars, gardana stone and brackets in 25 30mm avg. thick lime surkhi plaster ( 1 lime :1 surkhi : 1 coarse sand ) as per old traditional practice ( arches & mehrab in three coat of base course and subsequent course and low temping beating the shrinkage cracks and disappear then the work done as per the required work of restoration nature as per jaipur practice etc complete in all respect. 7 earth work in excavation by manually in foundation including dressing, levelling, ramming of bottom and disposal of surplus excavated soil within a lead of 50 mtr etc complete. 8 providing and laying lime concrete of roof terrace & floor portion with 50% composite mortar 1:1:1 lime mortar ( 1lime:1surkhi :1coarse sand ) and 20mm down gauge brick aggregate including beating with bamboo stick first & then with thaphi till the surface is harden to maintainthe proper slope & topsurface finishing etc. complete in all respect. 9 r.r. stone masonry with collected / available old stone in 1:1:1 lime surkhi mortar ( 1lime : 1surkhi : 1coarse sand ) mixed with adhesive material like gud, belgiri and babool gum including curing etc complete. 10 recess pointing with 1:1:1 lime surkhi mortar ( 1lime : 1surkhi : 1coarse sand ) mixed with adhesive material like gud, belgiri and babool gum including racking, cleaning and washing out joints with mixing hardener and colour pigment for matching the original etc complete. 11 taking and lowering down and replacement of the broken, cracked & missing chhajja stones by providing & fixing the 50mm thick avg. thickness ( bijoliya / bansi paharpur ) including making the grooves & joints and interlocking with s.s. rod ( nail ) and anchoring pin with lime mortar as per original etc complete. 12 taking out / removal / lowering down the broken / cracked sand stone slab 50 to 65 mm thickness on roof of temple& disposal them lead upto 100 mtr by head load etc complete. 13 providing & fixing sand stone slab 50 to 65 mm thick avg. on roof of temple including filling the joints with lime mortor1:1:1 ( 1 lime : 1 brick surkhi : 1 coarse sand ) etc complete 14 providing and laying 10 cm thick ( average ) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 ( 1 clay : 1 cow dung ) and covered with flat tile bricks, grouted with cement mortar 1:3 ( 1 cement : 3 fine sand ) mixed with 2% of integral water proofing compound by weight of cement andfinished neat with common burnt clay f.p.s. ( non modular ) brick tile of class designation 10 etc complete. 15 providing & laying the 6 mm thick lime punning with special lime mortor with lime, gum and marble dust of similor to orginial & preparing the surface for lime punning complete in all respect. 16 providing and laying app ( atactic polypropylene polymer ) modified prefabricated five layer, 3mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @0.40 litre / sqm by the same membrane manufactured of density at 25°c, 0.87 0.89kg / litre and viscosity 70 160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc and preparing the surface complete. the vital physical and chemical parameters of the membrane shall be as under: joint strength in longitudinal and transverse direction at 23°c as 350 / 300 n / 5 cm. tear strength in longitudinal and transverse direction as 60 / 80n softening point of membrane not less than 150°c. cold flexibility shall be upto 2°c when tested in accordance with astm, d 5147. the laying of membrane shall be got done through the authorized applicator of the manufacturer of membrane: 3mm thick. 17 providing and applying lime kara 1:2 ( 1 lime :2 zikki powder ) grinding mortar with grinding mill / manually on lime base, on ceiling and all flat surface in two coats. first coat applying 3mm to 4mm thick and curing properly at least 7 days, second finishing coat done after 7 days of previous coat as per traditional practice. ( thickness not more than 6mm ) 18 providing and fixing 40mm thick teak wood pannneled door on old patteren including old design iron nails, holdraft, chool, and iron ring with one coat of termiguard / primer & polishing etc complete including labour and material etc complete. 19 disposal of unwanted waste material / malba received from the site during the work by manually upto lead of 500 mtr from site area for site clearance and good appearance. ( note it is estimate purpose only actual qty will measured and recorded during execution of the work ) 20 erection and dismantlingscaffolding with wooden ballies and bamboo challiesincluding carrying the scafoldding material from store to working site then back to store etc complete....

Indian Army - Rajasthan

40685185 bids are invited for repair and maint and inverters of solar plant material and labour for checking the serviceability of inverter of 0 kw , material and labour for checking the serviceability of inverter of 100 kw , m and l for installation testing and commissioning of inverters , blank one , blank two total quantity : 5...

Indian Army - Rajasthan

40685184 bids are invited for repair and maint of inverters and spds in inverters material and labour for checking the serviceability of inverter , m and l for checking the serviceability of spds , m and l installation comma testing and commissioning , blank one , blank two total quantity : 5...

Indian Army - Rajasthan

40678883 bids are invited for disposable iv infusion pressure bag 1000ml , disposable iv infusion pressure bag 500ml , disposable labour kit , tennis elbow support , thoracic drainage catherer size 18f , thoracic drainage catherer size 20f , thoracic drainage catherer size 24f , thoracic drainage catheter size 28f , thoracic drainage catheter size 32f , three way silicon cathate total quantity : 162...

Department of Agricultural Research and Education - Rajasthan

40663519 tender for purchase of shade net house; size of shed net structure is 16mx28m. total covered area = 448 sqmt. structure erected on poles & clamp with clutch wires height of structure is 3m. shading material is agro shade net 35% white colour uv. side folding curtain system. features of structure : 1. rectangle shape along all peripheries to resist more wind impact 2.total galvanized and nut bolted structure. 3.structure is designed to resist wind velocity up to 120km / hr. 4.g.i. profiles to fix agro net. 35% u.v. stabilized agro shad net cloth technical specification : a. foundation : 1. foundation insert 1000mm long = 48mm o.d. 2. pit size – 400 dia & 600 mm depth with concrete ( pcc 1:3:6 ) . b. structure ( all galvanized pipes ) : 3. main column 3m. long up to top of the net house – 60mm o.d. 4. column to column distance 4m x 4m 5. purlins at top level = 48mm o.d. c. fixture : 6. all structure is assembled by using nut & bolts & clamps which are old galvanized. 7. c type profiles with zigzag spring inserts are used to fix agro net, purlins at top level = 48mm o.d. 8.door ; single door square pipe frame with fiber sheet size – 1mx2m 9. cladding material : 35% u.v. stabilized agro shade net cloth. 10. fogging system : four way foggers / sprinklers with 16mm lateral and pvc pipe, fitting, 1hp mono black pump, 2” screen. completed labour and transportation – fabrication and installation work as per requirement of indenter....

Indian Air Force - Rajasthan

40648562 bids are invited for manpower outsourcing services minimum wage unskilled; others; mazdoor / labour total quantity :...

Indian Army - Rajasthan

40636682 bids are invited for repair of power clamp meter material labour for repair replacement of ryb and neutral leads and testing up to the entire satisfaction of engineer in charge complete all as specified and directed , m l for replacement of 0.35 ohm cmos 1.65v to 3.6v spdt switch 2.1 mux for clamp meter creative tools ct pcm0208 as directed. , m l for replacement of 28v, 200ma low noise linear regulator suitable for electric meter creative tools ct pcm0208 as directed. , m l for replacement of 20v 200ma low noise linear regulator suitable for electric meter creative tools ct pcm0208 as directed. , m l for replacement of low capacitance charge injection 15v 12vicmos spdt in sot 23 suitable for electric meter creative tools ct pcm0208 , m l for replacement of 15v 2.5a synchronous buck boost dc convertor suitable for electric meter creative tools ct pcm0208 as directed , m l for replacement of power supply suitable for electric meter creative tools ct pcm0208 as directed. total quantity : 7...

Indian Army - Rajasthan

40622254 bids are invited for stitching charges of chandwa curtains and jhallar of motivational room , channel steel for curtains , fitting charges of labour curtains of motivational room , cloth red dark out mtr , cloth light blue dark out , cloth blue della , cloth yellow dependenz , 59 inch x 65 inch board for motivational room gate , board for motivational room sides of gate , 36inch x 48inch sermons for motivational room total quantity : 326...

Indian Air Force - Rajasthan

40581380 bids are invited for manpower outsourcing services minimum wage unskilled; others; mazdoor / labour...

Indian Air Force - Rajasthan

40570417 bids are invited for manpower outsourcing services minimum wage unskilled; others; mazdoor / labour total quantity :...

Board Of Secondary Education - Rajasthan

40551041 tender for e tender for labour confidential work, details of the work to be executed on contract by the confidential branch for e tender examination 2024 financial bis...

Jaipur Metro Rail Corporation Limited - Rajasthan

40533863 overhauling and testing of brake calipers ( including kit ) for rs 08 trains 2 labour charges for overhauling of brake calliper units ( service brake ) ( kb part no: ii85132 / 24mx ) 3 labour charges for overhauling of brake calliper units ( parking brake ) ( kb part no: ii85133 / 57124mx ) 4 cost of overhauling kit for service brake calliper ( kb part no: opk03952 ) 5 cost of overhauling kit for parking brake calliper ( kb part no: opk04185 ) 6 transportation charges from jmrc depot to contractor service centre & back to jmrc...

Indian Army - Rajasthan

40518656 bids are invited for cleaning machine gun, five hp three phase motor, iron, fan belt, charge labour, pulli total quantity : 309...

Indian Army - Rajasthan

40473509 bids are invited for repair of vehicle under ge banar labour for transport the vehicle to workshop for reparing through contractor , m and l for labour for dismantling both fuel filter engine oil 10w 40 09 ltr oil filter 02 , labour for removing the all pipe lines and taking down the diesel tank for servicing water , m and l for opening and draining out the gear oil from gear box and refilling the gear oil 80w 90l , labour for removing all engine manifold assembly inlet and outlet cleaning servicing , labour for disconnect the battery from vehicle, fill acid mixture into battery before charging the battery reconnecting it , m and l for overhauling of the break assembly with necessary machining and making alignment for smooth of the break , m and l for dismantling the steering box and servicing of steering box properly cleaning with suitable agents and replacement , labour for cleaning of complete internal surface of cabnet through brushes,vacum cleaner with necessary cleaning agent , m and l for servcing special washing removing dust top to bottom after drying polishing the vehicle properly , m and l for painting of body and cabnet outer side of vechicle make putty before applying paint paint be does quality total quantity : 14...

Indian Army - Rajasthan

40468137 bids are invited for repair of vehicle under ge banar labour for transport to local workshop for reparing by contractor directed by age em , m l for overhauling the gear box by dismantling gear box replacing item for smooth gear engaging, gear teeth 01 set, gear shifter spring 01 set , m l for replacement the main chain sprocket gear box and replacemnt of sprocket 01 set , m l for carrying out repairs to the electrical and generating system and repalcement of item, starting coil and lighting coil 01 set , m l for the broken centre stand and stand bushes spring from the vehicle and replacement item including machine work for fixing stand bush assembly, centre stand 01 set, bush and spring 01 set , labour for cleaning the petrol tank including servcing after dryin polishing the vehicle as satisfactory by age em , carrying out test run for road worthy and better mileage up to entire total quantity : 7...

Indian Army - Rajasthan

40465456 bids are invited for 1 dressed stone approx size ( 400mm x 200mm x 200mm ) rectangle ( squarred rubble jodhpur stone ) cum 44 2 cement ppc / opc 53 grade, make : jk lakshmi / ambuja / ultratech / shree / acc / birla isi marked ) bags 156 3 57 x pre cast rcc panels 125mm thk of various sizes as technical specification in ref drg no 9 &10. job 1 4 sand w / o bulking and as per relevant is specifications. cum 19 5 crushed graded aggregate 63mm ( as per relevant is ) cum 10 6 crushed graded aggregate 40mm ( as per relevant is ) cum 7 7 crushed graded aggregate 20 mm ( as per relevant is ) cum 3 8 crushed graded aggregate 10mm ( as per relevant is ) cum 2 9 cement base paint ( make : snowcem / jhonson / asian ) kgs 20 10 primer for distemper kgs 7 11 acrylic distemper ( make :jhonson / asian / nerolac ) kgs 10 12 liquid water proofing compund ( make : birla / acc / jk ) ltr 5 13 loop hole of size 400 mm x 400 mm as specified duly painted with two coats of 1st quality synthetic enamel paint over a coat of red oxide nos 2 14 ms shutter 6mm thick with mounting arrangements and loop hole of size 400 mm x 400 mm and 200 mm vertical slit as specified in ts duly painted with two coats of 1st quality synthetic enamel paint over a coat of red oxide nos 1 15 peep hole of size 150 mm x 150 mm as specified duly painted with two coats of 1st quality synthetic enamel paint over a coat of red oxide nos 6 16 ventilator as specified and as shown in drg duly painted with two coats of synthetic enamel paint over a coat of red oxide nos 2 17 steel door of size 900 x 1800mm as per drg and as specified duly painted with two coats of synthetic enamel paint over a coat of red oxide nos 1 18 sand bags18 x 34 hdpe, as per is nos 700 19 pre cast rcc m 25 lintelbeam of size ( 1800x400x250 ) mm nos 2 20 ismb 200 of each length 4200 mm of make tata / sail / jindal / bhushan ) duly painted with two coats of synthetic enamel paint over a coat of red oxide nos 4 21 ismb 200 of each length 3100 mm of make tata / sail / jindal / bhushan ) duly painted with two coats of synthetic enamel paint over a coat of red oxide nos 4 22 pad lock 6 lever 75mm dia make: godrej / harison nos 1 23 pbs roll ( 20m x 1m ) ( gfr based type ii of rods conforming to is 7193 ( make polyplast mk petro product / pidilite ( dr fixit ) roll 4 24 bitumen primer make : mak primer (mk petro products / pidilite (dr fixit) ltr 10 25 machine cut stone patti 75 mm thickness, 250 mm wide each and length as per requirement. sqm 25 26 machine cut stone patti 75 mm thickness, 300 mm wide each and 1400 mm length each for firing platfrom. sqm 9 27 machine cut stone patti 75 mm thickness, 300 mm wide each and 1800 mm length each for sleeping platfrom. sqm 3 28 machine cut stone patti 75 mm thickness, 250 mm wide each and 1400 mm length each for amn rack. sqm 8 29 machine cut stone patti 75 mm thickness, 250 mm wide each and 900 mm length each for steps. sqm 6 30 dressed stone of size 1100 mm(l) x 400 mm(b) x200 250 mm thick as lintel bend for ventilator and peep hole nos 3 31 dressed stone of size 600 mm(l) x 400 mm(b) x200 250 mm thick as lintel bend for ventilator and peep hole nos 4 32 paam solution for soil stab kgs 5 33 welding rods (make : sun weld / steel weld) isi marked pkt 6 34 skilled labour 2 nos per day day 10 35 hiring of jcb per pds (8 hour per day) day 1 36 cost of erection tools per pd set 1 ( q3 ) total quantity : 6...

Indian Army - Rajasthan

40455987 bids are invited for repair of vehicleunder ge banar labour for transport to local workshop for reparing by contractor directed by age em , m l for overhauling the gear box by dismantling gear box replacing item for smooth gear engaging, gear teeth 01 set, gear shifter spring 01 set , m l for replacement the main chain sprocket gear box and replacemnt of sprocket 01 set , m l for carrying out repairs to the electrical and generating system and repalcement of item, starting coil and lighting coil 01 set , m l for the broken centre stand and stand bushes spring from the vehicle and replacement item including machine work for fixing stand bush assembly, centre stand 01 set, bush and spring 01 set , labour for cleaning the petrol tank including servcing after dryin polishing the vehicle as satisfactory by age em , carrying out test run for road worthy and better mileage up to entire total quantity : 7...

Indian Army - Rajasthan

40450957 bids are invited for repair of vehicle under ge banar m and l for transport tolocal workshop for reparing by contractor directed by age em , m l for overhauling of engine by dismantling cylinder head piston engine replacement of engine valve 1 no sparking plug 1 no engine oil 20w 40 1 ltr , m and l for replacement of accelerator cable complete set with new one , m and l for replacement the weeken 12v horn with new one with wiring , m and l for replacement of broken indicator fornt and rear side complete with new one , labour for cleaning the petrol tank including and service of bike removing dust including poolishing after special washing complete , m and l for replacing the broken corroded battery box cover with new one of make everest paramount , m and l for replacement of seat including cover complete as strandard make of using seat cover total quantity : 8...

Military Engineer Services - Rajasthan

40439449 tender for repair / maintenance of sewage lines etc of zone c at lgj mil station.; 1 excavation in trenches n.exc. 1.5 m wide and n.exc. 1.5m in depth for foundation, shaft, manholes etc and n exc 10sqm on plan and getting out in any type of soil all complete all as specified. 2 excavating in trenches, n exc 1.5 m wide and exc 1.5 m in depth and n. exc 3.00 m in depth for foundation, etc. and n exc 10sqm on plan, getting out in any type of soil all complete all as specified. 3 returning, filling in, including spreading levelling including watering & well ramming in layers n. exc 25 cm as specified in soil complete all as specified and directed by engineer in charge. 4 removing excavated materials n.exc 50 mtr and depositing where directed at level n.exc. 1.50 mtr above the starting point complete all as specified and directed by engineer in charge. 5 demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. 6 m&l pcc 1:3:6 type c2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. 7 m&l for 100 mm thick pcc ( 1:4:8 ) type d2 using 40 mm graded stone aggregate as inbelowof dwcpe pipe line as a bed and provide required slopeall as specified and directed. 8 demolition of brick work built in cement mortar including plaster, coping etc of manholes / septic tank in any position complete all as specified and directed. 9 m&l fly ash brick work with sub class b brick straight or curved on plan exc 6m mean radius in cm 1:4 complete all complete and as specifed and directed. 10 m&l 15mm thick rendering on brick surfaces of wall in cm 1:4 finished even and smooth without using extra cement including mixing of wpc compound complete all as specified and directed.note : wpc shall be measured and paid separately. 11 supply only integral water proofing compound complete all as specified and directed. 12 demolition of breaking up drain pipes of internal dia 150 mm ( salt glazed ware, ac or reinforced concrete ) set in cement mortar or cement concrete complete all as specified and directed.note : earth work shall be measured and paid seperately 13 demolition of breaking up drain pipes of internal dia 200 mm ( salt glazed ware, ac or reinforced concrete ) set in cement mortar or cement concrete complete all as specified and directed.note : earth work shall be measured and paid seperately 14 supply and laying dwcpe ( sn8 ) 180 ( od ) / 163 ( id ) mm diameter drain pipes as per is 16098 ( part ii ) , laid in trenches onpcc bed to required slope, including all accessories / fittings, jointing and tested complete all as specified and as directed by engineer in charge.note : pcc bed and earth work shall be measured and paid separately. 15 supply and laying dwcpe ( sn8 ) 240 ( od ) / 200 ( id ) mm diameter drain pipes as per is 16098 ( part ii ) , laid in trenches onpccbed to required slope, including all accessories / fittings, jointing and tested complete all as specified and as directed by engineer in charge. note : pcc bed and earth work shall be measured and paid separately. 16 m&l pcc 1:2:4 type b1 using 20mm graded stone aggregates for coping & benching to main holes etc all as specified and directed. 17 material and labour for cleaning of blockage of bathroom, kitchen, urinals and whb at any location, at any height, at any floor by cleaning the nahani traps / gully traps by rodding / choke remover, manually or other wise including refixing of oval assess door covers with new nuts & washers, including removing of all wastes solid or liquid sludge in closed containter to any distance outside the cantonment area complete all as specified and as directed by engr in charge. 18 material and labour for cleaning of blockage of wc ( any type ) including cleaning of sgsw / cipipe of any lenght upto 1st manhole by rodding choke remover, manually or otherwise including refixing of assess door covers with new nuts & washers, including removing of all wastes solid or liquid sludge in closed containter to any distance outside the cantonment area complete all as specified and as directed by engr in charge 19 material and labour for cleaning of manholes including taking off manhole cover, closing of inlet / outlet of manhole / line and cleaning of manholes of any size n exc 1.5 sqm and depth up to 2m, using mechanized suction machine and removing of all wastes solid or liquid sludge in closed containter to any distance outside the cantonment area andreplacing manhole cover in position after cleaning complete all as specified and as directed by engr in charge.note: ( a ) contractor shall make his own arrangement for disposal off the sludge and no extra cost for the same shall be paid by the department ( b ) the manhole once cleaned, shall be kept functional through out the contract period. in case the manholes required to be cleaned again, same shall be done by the contractor at his own cost and no repitative payment shall be allowed for the same manhole ( c ) any damage caused during cleaning shall be made good to the entire satisfaction to engineer in charge by the contractor without any extra cost. 20 material and labour for cleaning of manholes including taking off manhole cover, closing of inlet / outlet of manhole / line and cleaning of manholes of any size exc 1.5 sqm andn exc 2.0 sqm and depth exc 2m but n exc 5.0m, using mechanized suction machine and removing of all wastes solid or liquid sludge in closed containter to any distance outside the cantonment area andreplacing manhole cover in position after cleaning complete all as specified and as directed by engr in charge.note: ( a ) contractor shall make his own arrangement for disposal off the sludge and no extra cost for the same shall be paid by the department ( b ) the manhole once cleaned, shall be kept functional through out the contract period. in case the manholes required to be cleaned again, same shall be done by the contractor at his own cost and no repitative payment shall be allowed for the same manhole ( c ) any damaged caused during cleaning shall be made good to the entire satisfaction to engineer in charge by the contractor without any extra cost. 21 material and labour for cleaning of manholes including taking off manhole cover, closing of inlet / outlet of manhole / line and cleaning of manholes of any size exc 2.00 sqm andn exc 3.0 sqm and depth exc 5.0 m but n exc 10.0m, using mechanized suction machine and removing of all wastes solid or liquid sludge in closed containter to any distance outside the cantonment area andreplacing manhole cover in position after cleaning complete all as specified and as directed by engr in charge.note: ( a ) contractor shall make his own arrangement for disposal off the sludge and no extra cost for the same shall be paid by the department ( b ) the manhole once cleaned, shall be kept functional through out the contract period. in case the manholes required to be cleaned again, same shall be done by the contractor at his own cost and no repitative payment shall be allowed for the same manhole ( c ) any damaged caused during cleaning shall be made good to the entire satisfaction to engineer in charge by the contractor without any extra cost. 22 m&l for cleaning of underground sgsw / dwcpe / sn2 sewage pipes ( cleaning of pipe length from manhole to manhole or from manhole to septic tank ) by using mechanised suction machine for sewage pipe lines of size 150 mm bore pipes and depth up to 2m complete all as specified and directed note: ( a ) cleaning of manholes if reqd shall be measured and paid seperately. ( b ) any damage caused during cleaning shall be made good to the entire satisfaction to engineer in charge by the contractor without any extra cost. ( c ) once cleaned the sewage lines, the contractor shall maintain the lines funtional upto date of completion. 23 m&l for cleaning of underground sgsw / dwcpe / sn2 sewage pipes ( cleaning of pipe length from manhole to manhole or from manhole to septic tank ) by using mechanised suction machine for sewage pipe lines of size 200 mm bore pipes and depth up to 4m complete all as specified and directed note: ( a ) cleaning of manholes if reqd shall be measured and paid seperately. ( b ) any damage caused during cleaning shall be made good to the entire satisfaction to engineer in charge by the contractor without any extra cost. ( c ) once cleaned the sewage lines, the contractor shall maintain the lines funtional upto date of completion. 24 m&l for cleaning of underground sgsw / dwcpe / sn2 sewage pipes ( cleaning of pipe length from manhole to manhole or from manhole to septic tank ) by using mechanised suction machine for sewage pipe lines of size 250 mm bore pipes and depth up to 5m complete all as specified and directed note: ( a ) cleaning of manholes if reqd shall be measured and paid seperately. ( b ) any damage caused during cleaning shall be made good to the entire satisfaction to engineer in charge by the contractor without any extra cost. ( c ) once cleaned the sewage lines, the contractor shall maintain the lines funtional upto date of completion. 25 m&l for cleaning of underground sgsw / dwcpe / sn2 central sewage pipes ( cleaning of pipe length from manhole to manhole or from manhole to septic tank ) by using mechanised suction machine for sewage pipe lines of size 250 mm bore pipes and depth up to 10 m complete all as specified and directed note: ( a ) cleaning of manholes if reqd shall be measured and paid seperately. ( b ) any damage caused during cleaning shall be made good to the entire satisfaction to engineer in charge by the contractor without any extra cost. ( c ) once cleaned the sewage lines, the contractor shall maintain the lines funtional upto date of completion. 26 supply and fixing in repairs cast iron acces door cover for 75mmbore pipes including all accesseries complete all as specified and directed. 27 , ditto as per srl item no 26 above but for 100mm bore complete all as specified and directed. 28 s & f in repair cast iron bends ( any radius ) with ducks foot or heel rest bend of 100mm bore dia complete all as specified and directed 29 s & f in repair cast iron bends ( any radius ) with ducks foot or heel rest bend of75 mm bore dia complete all as specified and directed 30 m & l cutting into existing manholes for connecting new drains, making good to pipe and rendering cutting out existing benching for and forming branche channel ( 1 / 2 round or 3 / 4 section ) in cement concrete 1:2:4 type b 1 20mm graded crushed stone aggregate smooth finished and forming benching as required, internal dia of pipe 150 mm complete all as specified. 31 demolition of reinforced cement concrete ( reinforcement cut as reuired to facilitate demolition ) complete all as specified and directed. 32 m & l precast cement concrete type b 1, 1:2:4 ( 20mm graded crushed stone aggregate ) as in manhole cover set in cm 1:4 including necessary form work complete all as specified. reinforcement shall be measured and paid seperately 33 m&l for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc 200 mm thick ( horizontal or sloping ) rough finish surface of concrete flat all as specified and directed. 34 m&l for reinforced cement concrete 1:1:2 using 12.5mm graded stone aggregrate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like; all as specified and directed.note : reinforcement shall be measured and paid seperately. 35 s & f tmt bars ( fe 500d ) 10 mm dia and over, cut to length, bend to shape required, including cranking spirally for hooping for columns, hooking ends and binding with and including mild steel wire ( annealed ) not less than 0.9 mm dia or securing with clips complete all as specified and directed. 36 s&f in repairs 110 mm dia pvc swr pipe, single socketed in any length with rubber ring joints fixed with clamps to walls complete all as specified and directed. 37 s & f in repairs 100 mm dia cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls complete all as specified and directed. 38 s & f in repairs 75 mm dia cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls complete all as specified and directed. 39 dismantling of cast iron swr pipes, jointed in cement mortar and taking it out of walls, complete all as specified and directed. 40 s&fin repair vitreous china wash down water closet ( pedestal pattern ) , white ( including seat cover, fixing bolts , flushing cistern and flush pipe ) , including connection to drain ( or outgoing pipe ) and to flushing pipe, antisyphonage pipe, etccomplete. 41 s&f in repair vitreous china wash hand basin colouredflat back of size 550x400mm with, 32mm dia chromium plated waste coupling long screwed shank and cp trap, including cutting for and pinning in ends of brackets in 1:3 cmcomplete all as specified . 42 s&f in repair vitreous china squatting pan orissa pattern size 580 x 440 mm white with integral foot restsbut including ci p trap set in and including concrete fixed complete all as specified and directed by engineer in charge. 43 s&f in repair kitchen sinks made of stainless steel 1mm thickwith plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to waste pipe, overall size 485 mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed by engineer in charge. 44 dismantling floor, hearth or wall tilingincluding cement mortar bedding ( but not backing ) , removingrubbish off the premises all as directed. 45 m&l for non skid coloured ceramic tiles ( joint less ) 7 to 8mm thick ( square / rectangular ) area of each tile exceeding 0.11 sqm but n exc 0.18 sqm as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 15mm thick screed bed or bedding layer in cement mortar ( 1:6 ) complete all as specified and directed 46 m&l glazed ceramic coloured tiles 450 x 300 x 7 mm thick joint less tiles as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 10mm thick rendering in cement mortar ( 1:4 ) including necessary cutting as per site requirement complete all as specified and directed 47 s&f factory made 75mm thick precast cement concrete drain cover slab of size 600 x 450 mm rectangular cover bearing capacity 2 mt including all accesseries required complete all as specified and directed. 48 s&f factory made 75mm thick precast cement concrete drain cover slab of size 900 x 450 mm rectangular cover bearing capacity 2 mt including all accesseries required complete all as specified and directed. 49 s&f factory made 75mm thick precast cement concrete drain cover slab of size 600 mm dia circular cover of 2 mt load bearing capacity including all accesseries required complete all as specified and directed. 50 m & l for dewatering from existing septic tanks and soak wells and disposal of effluent outside mod land ( in covered septic tankers ) complete all as specified and directed by engineer in charge note : contractor shall be responsible for providing necessary safety eqpt to the labour. 51 m & l for desludging by removing semi solid sludge from existing spectic tank, soak wells of any capacity and depth as in foul condition including taking up and placing in position manhole cover of any description, removal of sludge and solid contents to any place outside defence land ( in covered septic tanker ) complete all as specified and directed by engineer in charge.note : contractor shall be responsible for providing necessary safety eqpt to the labour. 52 note: the contract sum shall be calculated by deducting the amount shown in credit schedule attached to this tender, from total amount of schedule a / boq...

Indian Army - Rajasthan

40435132 bids are invited for manpower outsourcing services minimum wage unskilled; healthcare; ward boy , manpower outsourcing services minimum wage semi skilled; others; barber , manpower outsourcing services minimum wage unskilled; others; mazdoor / labour total quantity :...

North Western Railway - Rajasthan

40432021 supply of supply of drinking water to gang huts, l xings, gate lodges, stations and labour working in the section of aden/bhiwani. ( for 24 months )supply of drinking water to gang huts, l xings, gate lodges, stations and labour working in the section of aden/bhiwani. ( for 24 months ),...

Military Engineer Services - Rajasthan

40426696 tender for repair maintenance of lt distribution system and misc works at jalipa mil stn under ge army barmer; 1 excavating in trenches not exc 1.5m wide and not exc 1.5m in depth for foundation of poles, laying ug cables, etc and getting out in soft / loose soil complete all as specified and directed. 2 removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point in soft / loose soil complete all as specified and directed. 3 returning filling including spreading levelling, watering and well ramming in layers not exceeding 25cm in soft / loose soil complete all as specified and directed. 4 m&l for boring / drilling by machines / manual horizontally under the road in any type of soil without cuttiing / disturbing the existing road and inserting gi pipe of any size for drawing the cable complete all as specified and directed. ( gi pipe shall be measured and paid seperately. 5 material and labour for sand cushioning for under ground cables, spread in trenches, river sand including cleaning, spreading levelling, punning for laying / cushioning of cable with layer of 8 cm deep before laying cable and 15 cm depth after laying and stretching the cable complete all as specified and directed. note: for the purpose of payment punned thickness shall be measured. 6 supply and laying un reinforced precast concrete cable cover, class lv, type 1 flat, size 250 mm x 150 mm x 40 mm as mechanical protection to underground cables laying with length of the cable cover equal to the width of the trench complete all as specified and directed. 7 m&l for galvanised steel tube 50mm bore ( light grade ) laying in road / drain crossingfor cable protection pipe complete all as specified and directed.. 8 m&l for galvanised steel tube 50mm bore ( light grade ) fixed to pole / wall / floor for cable protection pipe includingclamp of ms flat of size 50x5mm and nut, bolt & washers of size 50x12mm for clamping of cable protection pipe with wall / pole as where required complete all as specified and directed. 9 m&l for pcc ( 1:4:8 ) type d 2 using 40 mm graded stone aggregate as in foundation filling & mass concrete for sub base of poles complete all as specified and directed. 10 m&l cement concrete 1:3:6, type c 2, ( using 40 mm graded stone aggregate ) for foundation of poles, stays, etc including form work as required / ordered complete all as specified and directed. 11 m&l cement concrete 1:3:6 type c1 ( using 20 mm graded stone aggregate ) as in coping of poles, padestal, etc including necessary form work etc complete all as specified and directed. 12 excavation in post holes ( or similar holes ) each not exc 0.5 cum getting out , returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard / dense soil complete all as specified and directed. 13 supply and laying in repair xlpe insulated, armoured, heavy duty electric ug cables withaluminium conductor 1100 volts grade complete including porviding lugs as required complete all as specified and directed for cross sectional area 10 sqmm 2 core. 14 all as per srl item no 13 above but of size 10 sqmm, 4 core 15 all as per srl item no 13 above but of size 16 sqmm, 2 core 16 all as per srl item no 13 above but of size 16 sqmm, 4 core 17 all as per srl item no 13 above but of size 25 sqmm, 3 1 / 2 core 18 all as per srl item no 13 above but of size 35 sqmm, 3 1 / 2 core 19 all as per srl item no 13 above but of size 50 sqmm, 3 1 / 2 core 20 all as per srl item no 13 above but of size 70 sqmm, 3 1 / 2 core 21 all as per srl item no 13 above but of size 95 sqmm, 3 1 / 2 core 22 all as per srl item no 13 above but of size 120 sqmm, 3 1 / 2 core 23 all as per srl item no 13 above but of size 150 sqmm, 3 1 / 2 core 24 all as per srl item no 13 above but of size 185 sqmm, 3 1 / 2 core 25 all as per srl item no 13 above but of size 240 sqmm, 3 1 / 2 core 26 dismantling / uprooting of lt unserviceable pre stressed concrete / steel poles of any size and length including taking out dismantled portion of poles embeded in concrete after necessary demolition ofconcrete foundation and disposal there of complete all as specified and directed 27 m&l for prestressed concrete pole, 9.0 metres long, 102 mm x 152 mm at top and 102mm x 289 mm at bottom, class 10 complete all as specefied and directed. 28 dismantling cross arms of ms channel or angle sections etc and keeping serviceable materials in safe custody for re use and / or unserviceable materials removing from the site complete all as specified and directed. 29 fixing only serviceable cross arm, ms channel, angle section obtained from item no 28 above after painting with one coat of aluminium paint including preparation of old steel surfaces complete all as specified and directed. 30 m&l cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections, including nuts, bots, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat ( red oxide, zine chrome primer ) , one under coat and one finishing coat of aluminium paint including preparation of surfaces complete all as specified and directed. 31 dismantling of acsr conductors or disturbed span including line spacer and keeping serviceable materials in safe custody for re use and unserviceable materials removing from the site complete all as specified and directed. 32 fixing only by re straining, tightening of acsr conductors of any size / type on lt poles including necessary new aluminium binding wire for fixing with insulator / pvc sleeves for jumper etc as required complete all as specified and directed. ( note:serviceable acsr conductors shall be obtained from item no. 31 above ) . 33 m&l for aluminium conductor steel reinforced ( acsr ) on lt poles including straining, binding with insulators with aluminium binding wire with insulator as in oh conductor, providing pvc sleeves for jumpers complete all specified and directed. 34 dismantling insulators of any type and any size and keeping serviceable materials in safe custody for re use and removing unserviceable materials from the site complete all as specified and directed. 35 fixing only serviceable pin type porcelain, vitreous, ( white / brown or green ) insulator for 1100 volts grade of any type obtained from item no 34 above. 36 fixing only serviceable shackle type porcelain, vitreous ( white / brown or green ) insulator of any size and shape for 1100 volts grade obtained from item no 34 above. 37 s&f pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade complete all as specified and directed. 38 s&f shackle type, porcelain, vitreous white, brown or green insulator including galvanised mild steel straps of size 31 x 3 mm, 12 mm dia insulator bolts, nuts and washers for working pressure 1100 volts of size 75 mm height, 90 mm dia complete all as specified and directed. 39 dismantling lt stay assembly, of any size and unserviceable materials removing from the site ( s ) , complete all as specified and directed.a ) unserviceable stay assembly shall be taken off / dismantled at ground level and making good disturbed ground surface.b ) rate is inclusive of necessary earthwork for demolition of cement concrete complete. 40 m&l stay assembly for lt complete with accessories as shown in electrical plate no. 1 of mes schedule part i, 16 mm dia stay rod, 7 / 3.15 mm galvanised stay strand complete all as specified and directed. ( note:loop insulator, stay clamps, excavation / earthwork and cement concrete shall be measured and paid for separately under relevant items of this schedule ) . 41 s&f in repair loop type insulators vitreous porcelainwhite / brown or green small size with overall dimensions 65x90 mm clearance of hole 16 mm dia complete all as specified and directed. 42 dismantling earth wire of any size / dia, guarding cradle of disturbed span and keepingserviceable materialsin safe custody for re use and removing unserviceable materials from the site complete all as specified and directed. 43 fixing only serviceable gi wire 3.15 mm or 4 mm dia obtained from item no 42 above complete all as specified and directed. 44 m&l for cradles, hexagonal / rectangular, fabricated or continuous earth wire with galvanised steel wire 3.15 mm or 4 mm dia complete all as specified and directed. 45 s&f in repair pvc fibre separator for lt line 1100 volt oh conductor 3 / 4 wire system for maintaining horizontal spacing of conductor complete with nut & bolt minimum two nos in a span complete all as specified and directed. 46 trimming of tree branches around the lt / ht oh conductor, pole & stay ( not less than 3 metre ) to clear the over head lines including cleaning of birdnest, creepers on poles and stays etc complete as required including removing and disposed off from the site directed. note : the quoted shall deemed to be inclusive of provision of periodically cleaning / cutting etc including disposal there off and span will be measured & paid only once in entire contract period. 47 m & l in repair earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick, burried directly in ground ( earth pit not less then 2.25m deep bellow ground level ) with top edge of the plate not less then 1.5m deep below normal ground level connected to galvanised iron strip of 32 x 6mm earth lead by means of bolt, nuts, washers of galvanised steel earth strip protected by and including gi pipe 40mm dia bore ( light grade ) and conncted to main test point directed and including concrete pit in pcc ( 1:3:6 ) type c 1 precast rcc ( 1:1.5:3 ) type a 1 cover slab 54 x 5 cm reinforced with 4mm dia tmt bars @ 150 mm c / c both ways with one handle for lifting made out of 8mm dia tmt bar embedded in precast cover slab funnel wire mens 20mm bore gi pipe ( medium grade ) for watering charcoal and salt in altemate layers, including necessary excavation and earth work in any type of soil complete all as shown on electrical plate no3 of ssr part i complete all as specified and directed. 48 m & l in repair earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground preferably vertically in ground with top edge not less than 1.25 mtr deep below normal ground level connected with and including galvanised iron wire 4 mm dia as earthing lead by means of nuts bolts and washers of galvanized iron protected by 15mm dia ( medium grade ) gi tubing, funnel, wire mesh, 20mm bore gi tubing ( light grade ) watering pipe, including concrete pit in pcc ( 1:3:6 ) type c 1, precast rcc ( 1:2:4 ) type b 1 cover slab of size 350x350x50mm reinforced with 8mm dia tmt bars @ 15cm c / c in both ways and 10mm dia ms handle ( 01 no ) of suitable size, charcoal and salt in alternate layers necessary excavation and earth work in soft / loose soil all as shown in electric plate no. 3 of ssr part i and testing on completion complete all as specified and directed. 49 supply, install, commission and testing in repair cubical type lt panel board , outdoor canopytype, manufactured by a cpri approved factory, floor mounted, dust & vermin proof, front and rear operated doorwithnecessary locking arrangement made of 50 x 6mm ms angle iron frame work and crca sheetof 3.00 mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. the panel shall be suitable for 415 volts, 50 hz, 3 phase 4 wire system and shall be complete with suitable capacity copper bus bar ( 1.5 times the incoming switch gear current rating ) with suitable size of pvc insulated copper conductor, thimbles glands complete all as specified and directed with the following accessories : incoming ( a ) mccb 4 pole, 415 volts, 250 amps, 25 ka 01 no.outgoing ( a ) mccb4 pole, 415 volts, 125 amps, 16 ka 01 no. ( b ) mccb4 pole, 415 volts, 100 amps, 16 ka 02 nos ( c ) mccb4 pole, 415 volts, 100 amps, 10 ka 01 nos ( spare ) ( d ) mcbtpn , 415 volts, 32 amps, 01 nos ( e ) digitalvaf meter for basic electric system monitoring 01 nos. ( f ) indicator lamp ( ryb ) ( set of three ) 01 set 50 s&f in repair tpn copper bus bar box, outdoor type of 200a capacity mounted on porcelain bridge insulator for one incoming cable and 4 out going cable, housing in sheet metal enclosure of ms sheet 3.0 mm thick crca sheet and angle iron 40x40x6 mm frame, painted with two coats including arrangement for cable gland for incoming and outgoing cables, locking arrangement, suitable foundation / platform for mounting the fpb with space for and including the following switch gears: ( a ) mccb 100 a fp, 10 ka ( for incoming control ) 51 preparation of old painted surface above the planting depth and pcc coping of steel tubular lt pole of09.00 metre length including ms clamps , cable protection pipe bracket fittedwith street light fittings etc by scraping with steel wire brush and applying two coats, of aluminium paint to external surface of poles ms cross arms ms clamp, cable protection pipe etc to give even shade including zebra colour of painting from 1.5 mtr height from the top of coping / bottom of pole as per site condition and numbering of poles complete all as specified and directed.note: zebra colour will be applied by synthetic enamel paint of black / yellow colour as approved in alternate layer of 30 cm height of each layer. 52 preparation of old painted surfaces and removing dust and other deposited material by scraping from lt pcc polesof09.00 metre length, cross arms brckets and applying 2 coats of aluminium paint to all steel surfaces, including ms clamps , cable protection pipe bracket fittedwith street light fittings etcincluding zebra colour of painting upto 1.5 mtr height from the top of coping / bottom of pole as per site condition and numbering of poles complete all as specified and directed. 53 supply and fix in repair energy efficient led street light fitting of 45 watt made up of pressuredie castaluminium housing with toughened glass and high power leds with secondary optics, efficacy 110 / 120 lpw, ip 66 protection aerodynamically designed for all weather conditions with efficient thermal management including 10 kv spd complete all as specified and directed .model: raptor neo cat no: trp 409 45 57 sl gl nsgof make cg or techno commercially equivalent model of havells, bajaj, wipro, halonix 54 supply and fix in repair energy efficient led street light fitting of 60 watt made up of pressuredie castaluminium housing with toughened glass and high power leds with secondary optics, efficacy 110 / 120 lpw, ip 66 protection aerodynamically designed for all weather conditions with efficient thermal management including 10 kv spd complete all as specified and directed .model: raptor neo cat no : trp 409 60 57 sl gl nsgof make cg or techno commercially equivalent model ofhavells, bajaj, wipro, halonix. 55 supply and lay in repair lt service cable 6 sqmm 2 core inside pvc conduit 20 mm dia medium grade for landscape lighting / garden lighting inside trench or on wall / floor complete all as specified and directed.note: the rate quoted must be inclusive of laying the cables in trench at max 10 cm depth or mounting on floor / wall 56 s&f integral compact wide beam led flood light luminiaire with die cast aluminium alloy housing with ip 66 protection, tampered protective toughened glass 5mm thick, thermal shock impact resistant cover, epoxy black powder coated finish, high purity pre anodised specular aluminium sheet reflector, with silver painted contacts suitable for 1x100 watts led and connection with two runs of 2.5 sqmm multi stranded, copper flexible wire including taking down old unserviceable one and testing complete all as specified and directed. make cat part no lhepczu7pa6j100 havells or techno commercially equivalent in wipro and crompton 57 supply and fix in repair led post top lantern of 45 w, ip 65 protection with in builtelectronic driver and aluminium housinginpure polyster uv resistant powder coated black finish, top maintainable product with top opening die cast cover , anti corrossive stainless steel screws & silicon gasket, het pmma diffuser conforming to is 10322 part 5 / sec 1: 1987, suitablefor pole diameter up to 75 mm , cable entrythrough pole from bottom, 3 way 10 amps gfp mains connector duly wiredupto terminal block complete all as specified and directed. make wipro cat part no: lp07 501 xxx 57 cl or techno commercially equivalent in bajaj, crompton, havells, halonix. 58 supply and fix in repair gi pipe bracket for street light fittings made out of 32 mm dia gi pipe light grade 1.5 mtr long bent to required angle / shape with and including necessary clamps, nuts, bolts, & washers of suitable size complete all as specified and directed. 59 s & f in repair pvc weather proof loop in loop out box with 4 pole terminal block mounted on porcelain or bakelite and mcb sp 06 amps for controlling including necessary clamps for mounting on pole etc complete all as specified and directed. make: sintex cat part no gsjb 2014 or techno commercially techno commercially equivalent. 60 supply, jointing and testing in repair cable jointing kit for 1.1 kv grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core xlpe armoured aluminium conductor cable of size 25 50 sqmm complete all as specified and directed. 61 supply, jointing and testing in repair cable jointing kit for 1.1 kv grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core xlpe armoured aluminium conductor cable of size 70 150 sqmm complete all as specified and directed. 62 supply, jointing and testing in repair cable jointing kit for 1.1 kv grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core xlpe armoured aluminium conductor cable of size 25 50 sqmm complete all as specified and directed. 63 supply, jointing and testing in repair cable jointing kit for 1.1 kv grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core xlpe armoured aluminium conductor cable of size 70 150 sqmm complete all as specified and directed. 64 s&f voltmeter, digital type, 0 500 volt with in built selector switch including taking down existing old / unserviceable voltmeter from lt panel / apfc panel board after carefully disconnecting the electric connection complete all as specified and directed 65 s&f ampere meter, digital type, 0 500 amps with in built selector switch, complete with suitable size of cts including taking down existing old / unserviceable ammeter from lt panel / apfc panelboard after carefully disconnecting the electric connection complete all as specified and directed. 66 s&f indicator lamp, led type of colour red, blue and yellow including taking down existing old / unserviceable lamps from lt panel / apfc panelboard after carefully disconnecting the electric connection complete all as specified and directed and asdtrected. 67 s&f mccb, 415 volts, 400 amp, breaking capacity 36 ka, 4 pole including taking down existing old / unserviceable mccb from lt panel / apfc panel board after carefully disconnecting the electric connection complete all as specified and directed 68 s&f mccb, 415 volts, 250 amp, breaking capacity 25 ka, 4 pole, including taking down existing old / unserviceable mccb from lt panel / apfc panel board after carefully disconnecting the electric connection complete all as specified and directed 69 s&f mccb, 415 volts, 200 amp, breaking capacity 25 ka, 4 pole, including taking down existing old / unserviceable mccb from lt panel / apfc panel board after carefully disconnecting the electric connection complete all as specified and directed 70 s&f mccb, 415 volts, 160 amp, breaking capacity 16 ka, 4 pole including taking down existing old / unserviceable mccb from lt panel / apfc panel board after carefully disconnecting the electric connection complete all as specified and directed 71 s&f mccb, 125 amp, 415 volts, breaking capacity 16 ka, 4 pole, including taking down existing old / unserviceable mccb from lt panel / apfc panel board after carefully disconnecting the electric connection complete all as specified and directed 72 s&f mccb, 100 amp, 415 volts, breaking capacity 10 ka, 4 pole, including taking down existing old / unserviceable mccb from lt panel / apfc panel board after carefully disconnecting the electric connection complete all as specified and directed 73 s&f in repair 3 / 4 pole contactor for capacitor switching ac 230 / 240 volt , 50 hzs coil operated suitable for iec rated 400 volt , 5 100 amps max complete all as specified and directed. 74 s&f contactor 3 / 4 pole ml 2.5 to 3.0 including taking down existing old / unserviceable contactor from lt panel / apfc panelboard after carefully disconnecting the electric connection complete all as specified and directed 75 s&f contactor 3 / 4 pole ml 4.0 including taking down existing old / unserviceable contactor from lt panel / apfc panelboard after carefully disconnecting the electric connection complete all as specified and directed 76 taking down the unserviceable capacitor from apfc panel and supply and fix cylindrical capacitorheavy duty of capacity 1 kvar complete all as specified and directed. 77 taking down the unserviceable capacitor from apfc panel and supply and fix cylindrical capacitor heavy duty of capacity 3 kvar complete all as specified and directed. 78 taking down the unserviceable capacitor from apfc paneland supply and fix cylindrical capacitor heavy duty of capacity 5 kvar complete all as specified and directed. 79 taking down the unserviceable capacitor from apfc paneland supply and fix cylindrical capacitor heavy duty of capacity 7.5 kvar complete all as specified and directed. 80 taking down the unserviceable capacitor from apfc paneland supply and fix cylindrical capacitor heavy duty of capacity 10 kvar complete all as specified and directed. 81 taking down the unserviceable capacitor from apfc panel and supply and fix ylindrical capacitor heavy duty of capacity 15 kvar complete all as specified and directed. 82 taking down the unserviceable capacitor from apfc panel and supply and fix cylindrical capacitor heavy duty of capacity 20 kvar complete all as specified and directed. 83 taking down the unserviceable capacitor from apfc panel and supply and fix cylindrical capacitor heavy duty of capacity 25 kvar complete all as specified and directed. 84 taking down the existing unserviceable automatic power factor control panel and supply and fix automatic power factor control panel microprocessor based incuding led display input voltage 415 v ac, + 15 %, 50 hzs, three phase delta connection with heavy duty cylindrical capacitor and8 step controlof capacity 10 kvar copmplete all as specified and directed. make: havells cat part no: qhktcb5010x0 or techno commercially equivalent in abb, siemens, l&t, schneider, c&s 85 taking down the existing unserviceable ct from the lt panel / apfc panel and supply and fix lt ct ring type suitable for primary current ratio 100 / 5 amps, burden 5 va, class 1.0 complete all as specified and directed.make: havells cat part no:qscelfbol001 or techno commercially equivalent in abb, siemens, l&t, schneider, c&s 86 taking down the unserviceable dimmer from the servo voltage stabilizer of 75 kva capacity and supply and fix dimmer or variable transformer of servo voltage stabilizer of 75 kva capacity complete all as specified and directed. 87 taking down the unserviceable carbon brush from the servo voltage stabilizer of 75 kva capacity and supply and fix new carbon brush of servo voltage stabilizer of 75 kva capacity complete all as specified and directed. 88 taking down the unserviceable buck boost transformer from the servo voltage stabilizer of 75 kva capacity and supply and fix new buck boost transformer of servo voltage stabilizer of 75 kva capacity including necessary wiring complete all as specified and directed. 89 material and labour for servicing of servo voltage stabilizer of 75 kva capacity including replacement of necessary wiring and copper lugs, contactors, relays etc complete all as specified and directed. note: rate quoted must be inclusive of necessary wiring and copper lugs required to be replaced but the contactors and relays if required to be replaced will be measured and paid separately....

Archaeological Survey Of India - Rajasthan

40425404 tender for special repair to jagat shiroman temple at amber distt. jaipur ( complete work ) ; 1 description of items and specification ofwork to be excuted. 2 providing and fixing 75mm dia b class gi pipe railing on the stair with the same pipe placed vertically at a distance of 1500mm c / c including cutting, hoisting and fixing in position with painting with synthetic enamel paint in two coat over a one coat of red oxide etc complete etc complete in all respect. 3 taking out the broken pieces of chhajja stone and providing 5 cm thick new chhajja stone after dressing, chiseling and fixing in 1:1:1 lime mortar ( 1liime : 1surkhi : 1c.sand ) mixed with traditional binding material i.e. belgiri, gud & gond etc. complete. with anchoring s.s. anchor pin of 8mm square rod. 4 providing and laying lime concrete with 20mm nominal size stone aggregate and 50% mortar in 1:1:1 ( lime :1 c.sand: 1 surkhi ) etc. complete. 5 random rubble masonry of boundary wall with cement mortar 1:6 ( 1 cement: 6 coarse sand ) in superstructure above plinth level including levelling up with cement concrete 1:6:12 ( 1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size ) etc complete. 6 recess pointing in white cement mortar 1: 2 ( 1white cement: 2 marble dust ) including racking, cleaning and washing out joints and matching the original etc complete. 7 providing and laying of 40mm thick red stone slab flooring ( banshi paharpur quarry stone ) over the bed of 20mm thick cement mortar 1:4 ( 1 cement:4 coarse sand ) including filling the joints mixed with colouring pigment to match the shade of the stone etc. complete . 8 providing and fixing of fine finished ( designed ) sand stone pan dasa 150 mm thick including making the grooves & joints and interlocking with dowel pin / anchor pin with lime surkhi mortar as per original etc complete. 9 repairing of wooden framed wire mess jaali with sagwan / teak wood support / planks to existing wire mess for avoid the entry of bats in the temple etc complete. 10 providing and fixing 40mm thick teak wood pannneled door on old patteren including old design iron nais, holdraft, chool, and iron ring with one coat of termiguard and wooden polish etc complete including labour and material etc complete. 11 providing and fixing 100mm thick bansi pahadpur buff colour stone bench of size 1.50x 0.60 x 0.45 mtr with two vertical support etc complete in all respect as per design / drawing attached. 12 supply and fixing 50mm thick bansi pahadpur buff colour stone ( un polished ) dustbin size 0.60 x 0.60 x 0.75 mtr in monument premise and surrounding area with moulding and carving complete including supplying and fixing isi mark pvc dustbin inside as per design / pattern / drawing attached. 13 providing and fixing of protection notice board in bilingual language with blue and red black ground and text in white colour with 50x50x6mm angle iron post and fixing in 1:2:4 ( 1 cement : 2 c.sand : 4 stone agg.20mm nominal size ) cement concrete blocks 0.40x0.40x0.60m etc complete in all respect. 14 erection of metallic / tubular scaffolding ( cup & lock type m.s tubes, m.s challies, m.s. clamps ) consisting of two rows of vertical secured or leashed together with horizontal and diagonal bracing and connecting to the structure at convenient point for better stability and propping of critical areas to provide effective supports before commencement of taking out / dismantling operations with essential safety features ( safety belt and helmet etc. ) for the workmanship etc complete....

Indian Air Force - Rajasthan

40353561 bids are invited for manpower outsourcing services minimum wage unskilled; others; mazdoor / labour total quantity :...

Public Works Department - Rajasthan

40349637 essential work assembly election 2023 at jamea tuli hidaya jamwaramgarh road under city dn.iii, jaipur. 1 half brick masonry in superstructure , above plinth level upto floor vlevelusing bricks of designation 75 : cement mortar 1 : 6 ( 1 cement : 6 coarse sand ) 2 plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 20mm thick . 3 demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer in charge. : in cement mortar. 4 renewing glass panes with wooden fillets wherever necessary : 4mm thick plain glass panes. 5 labour charges for repair to door / window without using any material such as applying randha ( finishing ) tightening of bolts & screw etc. 6 repairofdoor, windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : aldrop of mild steel 12 long x12mm dia 7 earth work in surface excavation not exceeding 30cm. in depth but exceeding 1.5 meter in width as well as10 sqm on plan including disposal of excavated earth up to 50 mtr. and lift up to 1.5 mtr. disposed soil to be levelled and neatly dressed : all kinds of soil 8 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: newwork ( twoormorecoats ) overandincludingscrappingandprimingcoatwithcement primer. 9 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means over areas ( exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan ) including disposal ofexcavated earth, lead upto 50m andlift upto 1.5 m , disposed earth to be levelled and neatly dressed : all kinds of soil 10 supplying and fixing in walls machine cut and polished stone shelves, tands andin cm 1:3 with machine cut edges : kota stone minimum 30mm thick. 11 p & f pvc storage tank isi marked ( is : 12701 ) indicating thebis license no ) , of approved make with cover, 25mm dia 1m long g.i. over flow pipe & 25 cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 500 litres capacity. 12 p & f g.i. pipes ( internal work ) with g.i. fittings excluding union ( is:1239 mark ) & ms clamps including cutting and making good the walls and floors: exposed on wall 15 mm dia nominal bore 13 p & f g.i. pipes ( internal work ) with g.i. fittings excluding union ( is:1239 mark ) & ms clamps including cutting and making good the walls and floors: exposed on wall 25 mm dia nominal bore 14 p & f bib cock ( is : 8931 mark ) , superior quality of approved make: c.p. brass long body, 15mm nominal bore weight not less than 690 gm 15 painting with synthetic enamel paint of approved brand and manufacture togive an even shade : two or more coats on new work 16 lettering with black japan paint of approved brand and manufacture. 17 beldar 18 building rubbish stone metal ( grit and ballast etc. ) 19 blacksmith 2nd class 20 carpenter 1st class 21 demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer in charge:in cement mortar. 22 random rubble stone masonry with hard stone in superstructure aboveplinth level and upto five levelabove 30cm. thick walls in : cement mortar 1:6 ( 1 cement : 6 sand ) ....

Public Works Department - Rajasthan

40344240 various work for arrangement of assembly election 2023 at rajasthan college and commerce college, jaipur half brick masonry in superstructure, above plinth level upto floor v level using bricks of designation 75 cement mortar 1: 3 ( 1 cement: 3 coarse sand ) brick work with f.p.s. bricks of class designation 75 in superstructure above plinth level upto floor v level in all shapes and sizes in cement mortar 1:8 ( 1 cement: 6 coarse sand ) plaster on new surface on walls in cement sand mortar 1:4 inclupling racking of joints etc. complete fine finish 20mm thick. providing and fixing double scaffolding system on the exterior side. upto five story made with 4 wooden member 1.5 m c / c horizontal and vertical direction joining with rassi, clamps, challies. the scaffolding system shall be stiffened with bracing, runner, connection of building if necessary with all essential safty features for the workmen etc complete as per direction of el.the lavation area of the scaffolding shall be measured for payment. the payment will be made once irrespective of duration of scaffolding. note: this item to be used for maintence work judicially dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. demolishing brick work manually by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer in charge. in cement mortar. repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape. raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead with cement mortar 1:4 ( 1 cement: 4 coarse sand ) patch repair to cement concrete floor including digging out old floor in regular shape and removal of rubbish curing etc. complete in all respects. making of hole ( width up to 150 mm ) in r.c.c. slab / wall / beams by power driven drilling machine complete as per direction of el upto 150mm thick providing and laying in position cement concrete including curing. compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. m15 grade nominal mix 1: 2: 4 ( 1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size ) . repair to stone masonary in cement sand mortar 1:8 with old and new stone. rough chisel dressed kota stone 35 mm thick flooring of approved shade set in pattern over 20mm thick base of cement mortar 1:6 ( 1 cement: 8 coarse sand ) and pointing with cement sand mortar 1:3 with pigment to match the shade of stone with joint thickness up to 15 mm complete in all respects: cement plaster 1:3 under old stone slabs with admixture ( gur, nails, binding wire to mesh and scraping scales & dressing joints of slabs complete. proofing above 25 mm thickness& upto 60 mm thickness providing and laying water proofing treatment in sunken portion of wcs, bathroom etc.. by applying cement slurry mixed with water proofing cement compound consisting of applying first layer of slurry of cement @ 0.488 kg / sqm mixed with water proofing cement compound @0.253 kg / / sqm.this layer will be allowed to air cure for 4 hours. second layer of slurry of cement @ 0.242 kg / sqm mixed with water proofing cement compound @ 0.126 kg / sqm this layer will be allowed to air cure for 4 hours followed by water curing for 48 hours. the rates includes preparation of surface treatment & sealing of all joints corners, junction with polymer mixed slurry. providing and laying in position cement concrete including curing. compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. 1:4:8 ( 1 cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size ) providing and laying of paver block as per is 15658 2006 ( indian standard for precast concrete block for paving specification ) and irc: sp:63 2004 ( guidelines for the use of interlocking concrete block pavement ) m 30, 60 mm thick to be used in non traffic areas like building premises, monument premises, land scapes, public gardens / park, domestic drives, paths and patios, embankment slopes, sand stabilization area etc. ( as per table 1 of is 15658:2006 category b denated only two side like i.z.t shape etc. as per irc sp 63:2004 earth work in surface excavation not exceeding 30cm. in depth but exceeding 1.5 meter in width as well as 10 sqm on plan including disposal of excavated earth up to 50 mtr and lift up to 1.5 mtr. disposed soil to be levelled and neatly dressed: all kinds of soil surface dressing of the ground including removing vegetation and inequalities not exceeding 15cm deep and disposal of rubbish lead up to 50 mtr. and lift up to 1.5 mtr.: all kinds of soil providing & laying tactile tile ( for vision impaired persons is standard of size 300x300x20mm and confirming to is 1231 of 1980 ( re affirmed in 2006 ) in all colours & sheds further product should confirm astm 303 for shad resistance and din51099 for colour fastness etc. laid on 20mm thick base of cement mortar 1:4 ( 1 cement: 4 course sand ) in all shapes & patterns including grouting the joint which white cement mixer ) will matching pigments etc complete is per direction of engineer in charges. grade m 30 providing and fixing designer cement concrete polished tiles over 20mm average thick base of cm 1:4 ( 1 cement: 4 sand ) jointing with cement mortar 1:21cement: 2 sand ) with pigment to match the shade of the tiles having minimum thickness of 25mm complete with all respect. ( as per is 1237:2012 ) chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement: 4 coarse sand ) dark shade using ordinary cement supply of beldar carriage of building earth, sand, lime, morrum manure or sludge including loading and unloading with all lead. carriage of building rubbish stone metal ( grit and ballast etc. ) including loading and unloading with all lead. part: b: joinery work labour charges for repair to door / window without using any material such as applying randha ( finishing ) tightening of bolts & screw etc. repair of door, window shutters including cost of material and labour for change of damaged: panel by shuttering ply 9mm thick ( commercial ) panel by wire gauge 14 mesh x 24 gauge aldrop of mild steel 12 long x12mm dia steel hinges for wooden chowkhat 4 size mild steel tower bolt 6 long steel locking bolt providing and fixing external grade board solid core single leaf flush door shutters isi 2202 67 marked using phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure a 30 mm thick. commercial veneer both side extra for providing extemal lipping with 2nd class teak wood battens 6 mm minimum depth on all edges of shutters ( over all area of door shutter to be measured ) over item no. 8.13. providing and fixing wood panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows ( area of opening for panel inserts excluding portion inside grooves or rebates to be measured ) . panelling for panelled and glazed shutter 25 mm to 40 mm thick is 710 1978 marked 19 mm thick commerical ply renewing glass panes with wooden fillets wherever necessary 4mm thick plain glass panes. providing and fixing is: 3564 marked aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. complete. providing and fixing s.s. rod 30mm dia ( 304 grade 16swg ) including brackets fixed with c.p. brass screws and rawl plugs, etc.. wherever necessary complete two side central all fittings. providing and foxing 12 mm thick prelaminated three layer medium density ( exterior grade ) particle board grade i, type ii conforming to is: 12823 bonded formaldehyde synthetic resin of approved brand and manufacture in paneling fixed in aluminium doors windows shutters and partition frames with c.p. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer in charge. pre laminated particle board with decorative lamination on one side and balancing lamination on other side. providing and fixing glazing in aluminium door, window ventilator shutters and partitions etc. with pvs / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge. ( cost of aluminium snap beading shall be paid in basic item. ) with float glass panes of 5.0 mm thickness ( weight not less than 13.50 kg / sqm ) providing and fixing 100mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete. providing and fixing aluminium u shape handle of size 100mm with ss screws etc. complete as per direction of engineer in charge powder coated minimum thickness 50 micron aluminium providing and fixing aluminum work for doors windows, ventilators and partition with extruded built up standard tubular / appropriate z sections and other sections of approved make conforming to is:733 and is:1285, fixed with rawl plugs and screws or with fixing clips.or with expansion hold fasteners including necessary filling up of gap. at junctions, at top bottom and sides with required pvc / neoprene felt etc. aluminium section shall be smooth rust free, straight, mitered and jointed mechanically wherever required including cleat angle aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws al. tower bolt & al. handle & al. aldrop etc., all complete as per architectural drawings and the directions of engineer in charge ( glazing and paneling to be paid for separately ) . for fixed portion powder coating aluminum ( minimum thickness of powder coating 50 micron ) for shutters builtup standard tubular sections of openable doors windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required ( lockes shall be paid for separately ) . powder coating aluminum ( minimum thickness of powder coating 50 micron ) supplying and fixing roller blinds of good quality and approved make made out of imported fabric including roller mechanism and lock with chain system with all necessary hooks etc. complete as per direction and sample approved by engineer in charge. labour charges for removing and refixing aluminium partitions door including minor repair on alteration in the same. providing and fixing stainless steel railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature ( wherever required ) and fitting the same with necessary stainless steel nuts and bolts complete, i / c fixing the railing with necessary accessones & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of engineer in charge. ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts fasteners etc. ) . grade 304 part c: steel work providing and fixing steel gate, grating and grills made of angles. tees, square bars, flats, or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide providing and fixing m.s. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of engg. incharge but excluding cost of chowkhats: including two coats of anit corrosive red oxide primer paint supplying and fixing of chain link fencing with angle iron posts 50x50x6mm placed at every 3 mtr. apart 30cm in ground embedded in cement concrete 1:3:6 ( 30x30x45cm ) corner and every tenth post to be strutted with ( 50 x 50 x 6cm ) angle iron provided and fixed and fitted with posts including earth work in excavation etc, complete with chain link size. 50mm x 50mm x 3.15mm providing and fixing welded mesh / expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete ( excluding frame work ) of size. welded mesh 25 mmx 25 mm x 2.1 mm repair of existing steel glazed doors, windows and ventilator, ms sheet door, garge doors, compound wall gates etc. by welding drilling complete include. cost of welding rods and hire charge of welding meachine and tp etc complete l / c for fixing of gi / ac sheet include. cutting jhiri and repair, cutting of sheet, fixing of sheet with j or l hook and bitumen washer as per direction of el supply and installation of multi rib proofing / cladding sheet manufacture out of 0.50mm tct ( total coated thickness ) high tensile zinc aluminum alloy coated galvalume steel ( as per 150gsm zinc aluminum coated 550mpa tuekd strength ) confirming to is: 1397 / astm a 792 sheet to have wide pens 30mm high nb at 250 centre and centre width of 1020mm sheets be casted with regular modified polyster system on a continuous with line on centre for face and with a polyster coating respectively sheet shall have proportionality with siphoned plate made to prevent leakage sheet shall be fixed by more of sell drilling lift tapping hot dip zinc coated hox head fasterner of size 12x14x55mm long. the sheet shall be supplied in cost one length and for a minimum up to 12mts with all scaffolding. part: d: painting work distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding old work ( one or more coats ) including scrapping surface and necessary repairs. colour change wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding old work ( one or more coats ) painting with synthetic enamel paint of approved brand and manufacture to give an even shade one or more coats on old work. removing dry or oil bound distemper by scrapping sand papering and preparing surface smooth including necessary repairs to scratches by sandla / loi and all scaffolding ( for colour changing only ) providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete new plastered surface ( three or more coats ) old plastered surface ( two or more coats ) wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding two or more coats on new work including prepartion of base with primer. putty, lippy etc complete in all respect. painting exterior surface of wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering. primer. putty. etc complete in all respect including scaffolding and safety provision old work lettering with black japan paint of approved brand and manufacture. part: e: sanitary work p & f water closet seat covers with brass hinges complete solid pvc ( is 2548 marked ) grade 1 black for ewc. p & f low level flushing cistern of 10 litres capacity ( is: 2556 mark ) of approved make with complete fittings c.i. brackets duly painted, brass ball cock with ball ( 15: 1703 mark ) complete including cutting and making good the wall pvc with pvc bend and superior internal fittings as per is:7231. p&f cp. brass urinal flush pipe set complete with flanged brackets of approved make. for 3 urinals p & f wvc wash basin ( ist quality is:2558 mark ) of approved make with c.i. brackets duly painted 1 no. 15 mm c.p. pillar cock ( is:8934 mark ) & 32 mm c.p. brass waste coupling of approved make, p.v.c waste pipe with pvc nut 32 mm complete including cutting & making good the wall size 580 mm x 450 mm p& f waste coulping with fittings of approved quality make: c.p brass 40 mm dia p& f waste pipe with all fitting p.v.c. with c.p. nut 40 mm dia p & f looking mirrors with p.v.c. frame of approved make as per direction of engineer in charge round 500mm dia p&f grating of approved quality / make c.p. brass with frame ( heavy ) & superior quality size 125mm dia. p&f g.i. pipes ( internal work ) with g.i. fittings excluding union ( is:1239 mark ) & ms clamps including cutting and making good the walls and floors: exposed on wall b class 15 mm dia nominal bore 25mm dia nominal bore p&f pilllar cocks ( is 8931: 1993 mark ) of superior quality and approved make c.p. pillar cock, 15 mm dia nominal bore p & f bib cock ( is: 8931 mark ) . superior quality of approved make c.p. brass bib cock, 15mm nominal bore. p & f ball cock ( 15:1703 mark ) with rod & p.v.c. ball complete brass wt. not less than 300 gm, 15mm. p&f inlet connection ( angle valves ) superior quality, of approved make, for wash basin, gyser etc. c.p. inlet connection with 37 cm long pipe and nut. p & f full way valve ( is:778 mark ) or wheel valve of approved make: gun metal 15mm nominal bore. gun metal 25mm nominal bore. gun metal 40mm nominal bore. providing and fixing unplasticized poly vinyl chloride ( upvc ) swr pipes type b for sciland waste discharge system ( is:13592 1992 marked ) of approved quality / make 110 mm dia providing and fixing unplasticized poly vinyl chloride ( upvc ) swr pipes fittings type b for sciland waste discharge system ( is:13582 1992 marked ) of approved quality / make door bend 87.5 dg. 110mm dia mechanised cleaning of sewer line of diameter upto 200mm with the help of trolley mounted electrical driven machine having flexible steel springs of length 20ft. each which are rotated with the help of electric motor and clutch assembly. repairing of cement concrete chambers of different size as per requirement at site and as per direction of engineer in charge. supplying & fixing r.c.c. manholes covers with frame of approved make ( light duty ) . size 500mm dia ( double seal ) supplying and fixing ferro cement cover with c.i. frame for chambers & man holes of size. 450mm dia. 5kg. c.i. frame to with stand 3 mt center point load & minimum unfractured load of 1 mt. ( light duty ) .a 500mm dia 12 kg. do 15 mt centre point load ( medium duty ) . raising manhole cover and frames slab to required level including dismantling existing slab and making good the damage as required ( raising depth of manhole masonry to be paid separately ) . rectangular manhole 90x60 cm p & f european type white glazed vitreous china 1st quality w.c pan ( is: 2558 mark ) with p or s trap including cutting and making good the wall and floor p & f ist quality wvc urinal ( is:2558 mark ) with 25mm dia g.i. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete. flat back ( large ) or half stall size 610x400x80mm. p&f marble urinal partition slab both sides polished of approved design cut from marble size 900x600mm. makrana il quality marble having light spots labour charges for removing and refixing of urinals ( all type & sizes ) including all necessary fittings. p&fc.p. brass urinal spreader for stall urinal of approved make. p&f plastic syphon of approved make for automatic flush tank. removing and re fixing of wash hand basin including all necessary fittings. providing and fixing new spindle for bib cock / pillar cock for repairing purpose to solve leakage and proper functioning of tap. labour charges for removing & refixing the water storage tank of all sizes and including all necessary fitting complete in all respect as per annoyed sample and direction of engineer in charge providing and fixing superior quality pvc tank cover complete as per approved by engineer in charge above 500 lt. capacity p&f inlet connection ( angle valves ) superior quality, of approved make, for wash basin, gyser etc. synthetic material ( ptmt ) inlet connection of approved quality / make 15 mm nominal size. p & f 15 mm. dia connection pipe of approved quality / make pvc pipe with c.p. brass nuts upto length, 600mm. p&f pvc storage tank isi marked ( is: 12701 ) indicating the bis license no ) . of approved make with cover, 25mm dia 1m long g.i. over flow pipe & 25 cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 500 litres capacity. 1000 litres capacity. hoisting charges for each floor: upto 750 litres capacity. above 750 litres capacity. providing and fixing superior quality cp brass fittings of approved make as per direction of engineer in charge swan neck pillar cock 15 mm nominal size bib cock with long thread 15 mm nominal size long body bib cock 15 mm nominal size angular stop cock with long thread 15 mm nominal size sink cock with swinging casted spout ( table mounted ) 15 mm nominal size 600 mm long towel rail revolving type towel ring health focet ( premium heavy quality ) as approved by engineer in charge...