Mohan Lal Sukhadia University - Rajasthan

38381797 electrical wiring and its accessories at visual arts new building in ucssh, mlsu, udaipur 1 wiring of light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked mms ( is:9537 p iii ) virgin material pvc conduit & itsisi marked ( is:3419 1988 ) accessories, round tiles, 1.2 mm thickhot dipped galvanized modular box with earth terminal, 10a modular switch, modular face plate with grid plate, 3 pin ceiling rose / holder / 3 way connector, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr, short point ( up to 3 mtr. ) 2 ..do.. medium point ( up to 6 mtr. ) 3 ..do… long point ( up to 10 mtr. ) 4 wiring of 3 / 5 pin 6 amp. light plug point with 1.5 sq. mm nominal sizefr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked mms ( is:9537 p iii ) pvc conduit & its isi marked ( is:3419 1988 ) accessories, hot dipped galvanizedmodular box of 1.2 mm thick with earth terminal, 10 a modularswitch, 3 / 5 pin 6 a modular socket, modular face plate with grid plate, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr, on board 5 ..do.. short point ( up to 3 mtr. ) 6 ..do … medium point ( up to 6 mtr. ) 7 s&f following sizes ( dia. ) of isi marked virgin material mms ( is:9537 p iii ) pvc conduit along withisi marked ( is:3419 1988 ) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. for additional technical parameters of product / work refer annexure a attached with this bsr , 20 mm 8 …do … 25 mm 9 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from99.90 % purity copper, class 5 stranding in acc. to is:8130 / iec 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation pvc type a / c / d , flame retardant as per is 10810 53, better amperage rating as per is:3961 part 5, in existingsurface or recessed pvc / ms conduit / casing capping making connections with copper lugs of suitable size, ferrules, testing etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of product / work refer annexure a attached with this bsr, 3 x 1.5 sq.mm 10 …do… 2 x 2.5 sq. mm. + 1x1.5sqmm 11 …do … 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 12 ..do… 4 x 6 sq.mm 13 supply & drawing wiring for sub mains isi marked ( is:694 ) 1100 volts grade pvc insulated flat twin core sheathed solid aluminium conductor with 10 swg g.i. support wire duly clipped etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr, 10.0 sq.mm 14 p & f paper phenolic resin bondedlaminates confirming to is : 2036 1995 for boxes / frames including making holes for switches etc, with brass screws, washers / zinc platednut and bolts as required. for additional technical parameters of product / work refer annexure a attached with this bsr, 3.0 mm thick 15 …do… 6.4 mm thick 16 p & f phenolic laminated sheet 2.0 mm thick of following size . including screws, cup washer as required.for additional technical parameters of product / work refer annexure a attached with this bsr, 75 mm dia 17 …do…100 mm dia. 18 providing & fixing of 240 / 415 v ac mcb with positive isolation of 10 ka breaking capacity ( b / c / d tripping characteristic as per type of load andsite requirement ) 4 kv impulse withstand voltage, isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted inexisting distribution board / sheets, minimum electrical operation 20, 000 upto 20 a rating and 10, 000 upto 63 a, 5000 for 80 a & above ratingincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr, single pole mcb ( with b / c curve tripping characteristics ) , 6 a to 32 a rating 19 ..do.. double pole mcb ( with b / c curve tripping characteristics ) 6 a to 32 a rating 20 providing & fixing of 240 / 415 v isolatorisi marked is:13947 iii / conforming to iec 60947 3, suitable for ac22a utilization category, 4kv impulse withstand voltage, true contact indication, red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm.ip 20 contact protection and fitted in existing distribution board / sheetincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr, four pole isolator, 80 a / 100 a rating 21 providing & fixing of recessed / surface mounting heavy duty horizontal type double door ( metal / glazed ) distribution board with metal end box made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3, powder painted complete with reversible door ( for double door db only ) 100 amp. insulated copper bus bar / shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar, masking sheet, making internal db terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr, metal door ( single phase ) ik 09 and ip 43 with metal end box, 8 way ( 8+2 ) 22 …do… 12 way ( 12+2 ) 23 providing & fixing of recessed / surface mounting heavy duty enclosure made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3. powder painted complete with din rail making internal db terminations with copper lugs, detachable gland plate, including making connections, testing etc. as required.for additional technical parameters of product / work refer annexure a attached with this bsr, suitable for two / three / four module for mcb 24 providing & fixing of recessed / surface mounting heavy duty vertical tpn distribution board with metal end box withprovision of incomer suitable for mcb / rccb and sp / tp mcb as outgoing , made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3. powder painted with reversible door ( for double door db only ) complete with insulated 100 a rating copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar, masking sheet, making internal db terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr, double door ik 09 & ip 43 with metal end box, 4 way ( 8+12 ) 25 providing & fixing of modular type 120 w step fan regulator duly isi marked ( is 11037:1984 ) with cm / l no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , includingall as per pre approved by engineer in charge, making connections, testing etc. as required.for additional technical parameters of product / work refer annexure a attached with this bsr, 5 step fan regulator 2 module 360 dgree rotating 26 supplying and fixing of power plug point with modular accessories as per pwd specification for electrical works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal / connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofisi marked modular 16 amp. switch ( is :3854 ) and 6 / 16 amp. socket outlet ( is:1293 ) making connection , testing , etc. as required. for specification ofwiring accessories refer chaptere 07related item & for additional technical parameters of product / work refer annexure a attached with this bsr 27 sitc of3 / 4pole current limiting moulded case circuit breaker ( mccb ) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440 / 415 v, 50 hz; o / l & s / c settings , conforming to is / iec 60947 p 2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push ( test ) to trip, trip time less then 10 ms under s / c condition, breaking capacity ics = 100% icu. u imp =8 kv, rated insulation voltage690 v.provision for uvr , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.oem shall have submitnabl / cpri / erda accrediated lab type test certificate before execution all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr, 4 pole mccb with thermal magnetic release, up to 100 amp , 25 ka, adjustable o / l & adjustable s / c setting, 28 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed un arrmouredaluminiumcable confirming to is:1554 p i / is :7098 p i of 1.1 kv withh4 grade electrolyticaluminium conductor confirming to is 8130 of purity >99.6 %, inner / outer sheath confirming to is:5831in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench / cable tray ( with cable tie ) includingtesting etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810. for additional technical parameters of product / work refer annexure a attached with this bsr, 16.0 sq. mm, 4 core 29 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed arrmouredaluminiumcable confirming to is:1554 p i / is :7098 p i of 1.1 kv withh4 grade electrolyticaluminium conductor confirming to is 8130 of purity >99.6 %, round / flat strip armouring of cables, inner / outer sheath confirming to is:5831in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench / cable tray ( with cable tie ) includingtesting etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810.for additional technical parameters of product / work refer annexure a attached with this bsr, 35.0 sq. mm, 3.5 core 30 providing & fixing ofbeestar rated copper wounded double ball bearing capacitor start, aluminium body & metallicblade ceilingfanconforming to all the performance requirements laid down in is 374:2019 including all amendments, as applicable ; & carry bis licensing ( i.e. isi marking ) with down rod up to 80 cm with secondary support safety cable ( steel rope ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr, 1200 mm sweep bee 1 star rated ( service value >=4.0 to < 4.5 ) 31 providing & fixing ofof double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor , making connections, testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr, 300 mm sweep 32 providing & fixing of energy efficient direct fit ( retrofit ) polycarbonate / glasshousingsmd mid power led tube rod ( with integral driver & alumn. heat sink ) , on existing fixture.system lumen efficacy = 100 lm / watt output, internal surge protection of 2.5 kv , thd < 20% , p.f.=0.95, cri >80 , life time of minimum35000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr, 1200mm , min. lumens output 2000 lmled tube rod with polycarbonate housing 33 providing & fixing of ip 20 led recessed / surface mounted, round / sqauresmd mid power led downlight with power coated die cast aluminum housingwith uv stabilized non yellowish diffuser withbis complience 2.5 kv surge protected isolated driver, with short & open circuit protection, having efficiency > 85% . system lumen efficacy of = 110 lm / watt, thd < 10 % , pf.=0.95, cri >80, life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. ( oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr ) , surface mounting ( with extruded alumn. housing ) , minimum lumen output 1950 lm 34 providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket / pole. fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with uv stabilized pc ( uv stablization report submitted for uv cover ) / toughened glass coverand secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm / wt and potted driver& has a unique bis r number withinput voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driverefficiency >85%, thd ( i ) <10%humidity 10% to 90% rh working temp 5c to 45c .driver current <750ma. the luminaireshall be bis certified and trade mark certified. life expectancyequal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min = 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs.manufactures word mark / name engraved / embossing on die cast housing to allow traceability / authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities forled fixtures. ( lm79 / lm80 ) certificate / report with liable warranty of product / accessories from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr .led street light fixture with minimum lumen output 7500 lm 35 providing & fixing of street light bracket made out from following size of b class , medium class g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with heavy duty pole clamp, saddles suitable fastners etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr, 32 mm dia. 36 providing & fixing ofextra down rod of 15 mm dia . erw ( electrical resistance welded ) of 1.6mm nominal thick medium duty steelpipe including cutting, threading, drilling, fixing quarter pin etc as reqd.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr ....

Medical Health And Family Welfare - Rajasthan

37748513 tender for electrical work phc building janunda, district pali., 1 ( electrical bsr 2022 rajasthan ) wiring of light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) in recessed isi marked mms ( is:9537 p iii ) virgin material pvc conduit & its isi marked ( is:3419 1988 ) accessories, round tiles, 1.2 mm thick hot dipped galvanized modular box with earth terminal, 10a modular switch, modular face plate with grid plate, 3 pin ceiling rose / holder / 3 way connector, screws, making connections, testing etc. as required. for specification of copper conductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr. short point ( up to 3 mtr. ) 2 medium point ( up to 6 mtr. ) 3 long point ( up to 10 mtr. ) 4 wiring of twin control light point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) in recessed isi marked mms ( is:9537 p iii ) pvc conduit & its isi marked ( is:3419 1988 ) accessories, round tiles, 2 nos hot dipped galvanized m.s modular box of 1.2 mm thick with earth terminal, 2 nos10 a two way modular switch, 3 pin ceiling rose / holder / 3 way connector , modular face plate with grid plate, screws, making connections, testing etc. as required. for specification of copper conductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr. medium point ( up to 6 mtr. ) 5 long point ( up to 10 mtr. ) 6 wiring of 3 / 5 pin 6 amp. light plug point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) in recessed isi marked mms ( is:9537 p iii ) pvc conduit & its isi marked ( is:3419 1988 ) accessories, hot dipped galvanized modular box of 1.2 mm thick with earth terminal, 10 a modular switch, 3 / 5 pin 6 a modular socket, modular face plate with grid plate, screws, making connections, testing etc. as required. for specification of copper conductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr. on board 7 supplying and fixing of power plug point with modular accessories as per pwd specification for electrical works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal / connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of isi marked modular 16 amp. switch ( is :3854 ) and 6 / 16 amp. socket outlet ( is:1293 ) making connection , testing , etc. as required. for specification of wiring accessories refer chapter e 07 related item & for additional technical parameters of product / work refer annexure a attached with this bsr 8 s&f following sizes ( dia. ) of isi marked virgin material mms ( is:9537 p iii ) pvc conduit along with isi marked ( is:3419 1988 ) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. for additional technical parameters of product / work refer annexure a attached with this bsr. 20 mm 9 25 mm 10 32 mm 11 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from 99.90 % purity copper, class 5 stranding in acc. to is:8130 / iec 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation pvc type a / c / d , flame retardant as per is 10810 53, better amperage rating as per is:3961 part 5, in existing surface or recessed pvc / ms conduit / casing capping making connections with copper lugs of suitable size, ferrules, testing etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of product / work refer annexure a attached with this bsr. 1 x 1.5 sq.mm 12 2 x 2.5 sq. mm. + 1x1.5sqmm 13 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 14 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. 15 1 x 4.0 sq.mm 16 4 x 6.0 sq.mm 17 4 x 10.0 sq.mm 18 providing & fixing of isi marked surface type buzzer ( is:2268 1994 ) with cm / l no. printed including making connection testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 19 p & f phenolic laminated sheet 2.0 mm thick of following size . including screws, cup washer as required.for additional technical parameters of product / work refer annexure a attached with this bsr. 75 mm dia 20 p & f 1.2mm thick m.s. recessed fan box, hexagonal / round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 21 providing & fixing of modular type 120 w step fan regulator duly isi marked ( is 11037:1984 ) with cm / l no. printed made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with ip 20 rating , including all as per pre approved by engineer in charge, making connections, testing etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr. 5 step fan regulator 2 module 360 dgree rotating 22 providing & fixing of following modular accessories as per pwd specification for electrical works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with ip 20 rating , including all as per pre approved by engineer in charge, making connections, testing etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr. blanking plate 23 25 amp. 2 module motor starter with on / off push button 24 providing & fixing of modular type lockable feature socket duly made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with ip 20 rating , including all as per pre approved by engineer in charge, making connections, testing etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr. 25 amp. 2 module socket 25 providing & fixing of extra down rod of 15 mm dia . erw ( electrical resistance welded ) of 1.6mm nominal thick medium duty steel pipe including cutting, threading, drilling, fixing quarter pin etc as reqd. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 26 p & f of gravity louver shutter of superior quality made out of frame of 18 swg m.s. sheet & louvers made from 24 swg ms sheet with enamel paint including cost of nuts, bolts, etc as reqd. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr .up to 380 mm size 27 supplying and drawing pe insulated & pvc sheathed unarmoured telephone cable with 0.5 mm dia. solid annealed electrolytic grade bare copper conductor as per is: 8130 / 84 &confirming to tec specification gr / wir / 06 03 march 2002 in existing surface or recessed conduit / casing capping. including ferruling on each pair for identification etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr. 3 pair 28 5 pair 29 50 pair 30 20 pair 31 p & f krone module with base frame in the recess / surface made out of 1.2 mm thick sheet steel box, front openable, having locking arrangements duly powder painted, including dressing, ferruling and punching of telephone cable with krone tool etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr. 20 pairs 32 50 pairs 33 p & f 1.2 mm thick g. i. / m .s. sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes ( nominal size ) in recessed / surface as required.for additional technical parameters of product / work refer annexure a attached with this bsr. 1.2 mm thick m. s. sheet boxes 175mm x 100mm x 60mm 34 p & f paper phenolic resin bonded laminates confirming to is : 2036 1995 for boxes / frames including making holes for switches etc, with brass screws, washers / zinc plated nut and bolts as required. for additional technical parameters of product / work refer annexure a attached with this bsr. 3.0 mm thick 35 providing & fixing of flush type non modular single line telephone jack made out fromindustrial grade polycarbonate or fire resistant abs material, including making connection testing etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 36 supply, drawing and testing of 4 pair, 23 awg solid bare copper wire insulated with pvc, utp ( unshielded twisted pair ) , category 6, class e, 100 ohm impedance, indoor cable as per latest ammendments of ansi / tia / eia 568 , the copper conductors should be balanced twisted in pairs, seperated by a cross member fluted pair divider & protected by pvc jacket. certified performance in a 4 connector configuration upto 100 mtrs channel requirements & transmission frequencies up to 250 mhz. in existing ms / pvc conduits / casing capping including making connections to information outlets and patch panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 37 supply and installation of unsheilded / 360 degree sheilded information outlets made of high impact plastic body with abs, fr grade halogen free material with provision for protection against dust in jack, suitable for cat 6 / 6a application complying to latest ammendments, according. to cat. 6 / 6a channel, it should support channel as well as components requirements of cat.6 / 6a standards at frequencies of up to 250 to 500 mhz. cat 6 / 6a unshielded / shielded jack should be suitable to terminate 4 pair, 23 / 24 awg solid / stranded wire diameters, using 100 ohm unshielded / shielded balance twisted pair cable, the jack should have tooless / impact termination on reliable copper tin plated insulation displacement contact, with easy lock mechanism, it supports iec 60603 7 4 and complied with ansi / tia / eia 568 c.2 standard. jack should be rj11, rj12 & rj45 compatible. should support ethernet 1.2 gb / s atm, digital video and broadband / baseband analog video, voice over internet protocal ( voip ) specifications in existing modular / ms boxes along with necessory connections as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . cat 6, un sheilded information outlet 38 supply & fixing of square faceplate for flush / surface mount information outlets single / dual or quad aperture , material should be pc+abs body, suitable for rj45 unshielded / shielded connection modules. should match with i. o. oem. dimensions should be 86mm x 86mm as required complete in all respect. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . single aperture 39 providing & fixing of 240 / 415 v ac mcb with positive isolation of 10 ka breaking capacity ( b / c / d tripping characteristic as per type of load and site requirement ) 4 kv impulse withstand voltage, isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted in existing distribution board / sheets, minimum electrical operation 20, 000 upto 20 a rating and 10, 000 upto 63 a, 5000 for 80 a & above rating including making connections, testing etc. as required. oem shall have submit nabl / cpri / erda accrediated lab type test reports & all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr. single pole mcb ( with b / c curve tripping characteristics ) 6 a to 32 a rating 40 triple pole mcb ( with b / c curve trippingcharacteristics ) 6 a to 32 a rating 41 four pole mcb ( with b / c curve tripping characteristics ) 6 a to 32 a rating 42 50 / 63 a rating 43 providing & fixing of recessed / surface mounting heavy duty horizontal type double door ( metal / glazed ) distribution board with metal end box made out from galvanized steel / crca sheet not less then 1.2 mm thick  conforming to is 8623 1 & 3 /   iec 61439 1 & 3, powder painted complete with reversible door ( for double door db only ) 100 amp.  insulated copper bus bar / shorting link , copper neutral link, copper earth link , color coded interconnecting wire set  of suitable rating and din bar, masking sheet,   making internal db  terminations with copper lugs, ferrules,   detachable gland plate, including making connections, testing etc. as required. oem shall have submit nabl / cpri / erda accrediated lab type test reports & all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr. metal door ( three phase ) ik 09 and ip 43 with metal end box 6 way 44 8 way 45 providing & fixing of 240 / 415 v residual current circuit breaker ( rccb ) conforming to ( is:12640 1 ) / iec 61008 1 , rated 4 kv impulse withstand voltage truly current operated and shall operate on cbct mechanisum, provision for pad lock, min. operation 10, 000 upto 63 a rating and 5000 for 100 a rating and minimum phase termination capacity of 35 sq.mm. rigid wire , ip 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. oem shall have submit nabl / cpri / erda accrediated lab type test reports & all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr. four pole 100 / 300 ma sensitivity 63 a rating 46 providing & fixing of recessed / surface mounting heavy duty vertical tpn distribution board with metal end box with provision of incomer suitable for 3 / 4 pole mccb and sp / tp mcb as outgoing , made out from galvanized steel / crca sheet not less then 1.2 mm thick  conforming to is 8623 1 & 3 /   iec 61439 1 & 3. powder painted with reversible door ( for double door db only ) complete with insulated 160 ( upto 160 a incomer ) / 250 amp.  copper bus bar, neutral bars with shrouds,   earth bar , color coded interconnecting wire set  of suitable rating and din bar, masking sheet,   making internal db  terminations with copper lugs, ferrules,   detachable gland plate, including making connections, testing etc. as required.  oem shall have submit nabl / cpri / erda accrediated lab type test reports & all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr. double door ip 43 & ik 09 with provision of incomer mccb 160 a rating with metal end box 6 way 47 supply and installation of high tensile low carbon steel rod molecularly bonded with 99.9 % copper thickness ( 250 microns ) and confirming to ul 467, is / iec 62561 2 of following size and length and as per point mentioned ( a ) , ( b ) , [ c ) , ( d ) , ( e ) below : ( a ) bore a hole of dia. 100 mm of required length, place the rod in the centre of hole ( b ) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, cpri / erda tested with rms capacity of minimum 30 ka for withstanding 1 second .to ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. the compound shall be tested form nabl acredeated lab for low resistivity ( less than 0.12 ohm meter ) & high conductivity in nature with carbon as a major content as per referance of is 3043 1987, ieee 80 2013 ( clause 14.5d ) , ieee 837 & ier 1956 with latest amendemnts © connect the rod with copper strip / conductor / wire with suitable clamp made from tinned copper and ss 304 bolt. ( d ) place heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height 250 to 300 mm. ( d ) testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. ( e ) test certificates for confirming above standards from oem is mandatory. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 17.2 mm thick and 3 mtr. long 48 supply & laying following size earth strip in horizontal or vertical run in surface by means of earth strip dmc insulator including riveting / soldering / welding, jointing shall be done by overlapping and with 2 set of brass ( for cu strip ) / gi ( for gi strip ) nut bolt & spring washer spaced at 50cm making connection etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 25mm x 3mm copper strip 49 25mm x 3mm g.i. ( hot dipped ) strip 50 providing & fixing of bee star rated copper wounded double ball bearing capacitor start, aluminium body & metallic blade ceiling fan conforming to all the performance requirements laid down in is 374:2019 including all amendments, as applicable ; & carry bis licensing ( i.e. isi marking ) with down rod up to 80 cm with secondary support safety cable ( steel rope ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 1200 mm sweep bee 1 star rated ( service value >=4.0 to < 4.5 ) 51 providing & fixing of heavy duty capacitor start, copper wound double ball bearing 900 / 1400 rpm single phase exhaust fan conforming to is:2312 isi marked in existing opening including making connections testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr .300 mm sweep ( 900 / 1400 rpm ) 52 providing & fixing of of double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor , making connections, testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 225 mm sweep 53 providing & fixing of 450 mm sweep oscillating type wall mounting / pedestal type fans with three speed, on and off position, sintered iron bush oil impregnated, with metal front and back 120 or more ribs guard; three no. aluminium blades, minimum air delivery 100 cum. / minute , minimum service value 1.11 cum. / min / watt, noise level should be <= 75 db, power consumption <= 120 watts, motor protection through thermal overload protection device, including fixing with anchor bolts, making connection testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . wall mounting type with adjustable vertical angle 54 providing & fixing of ip20 smd mid power led batten type integrated light fixture made from powder coated extruded aluminium housing with in built driver , system lumen efficacy ≥ 110 lm / watt output, internal surge protection of 2.5 kv with short & open circuit protection , thd < 10% , p. f.≥0.95, cri >80 , life time of minimum 50000 burning hours with , 70% of intial lumen maintaned till life ends , cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be of bis standard and trade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing on housing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 1170mm ( + / 10% ) led batten with min. lumen output 2200 lm 55 providing & fixing of ip20, 2x2 led surface / recessed mounting mid power smd type led light fixture not less than 50mm housing depth made from crca sheet steel housing, high purity / transmisivity uv stabilized non yellowish diffuser for uniform light distribution. high efficiency with 4 kv internal / external surge protection bis certified isolated driver having efficiency > 85% , with short & open circuit protection ( integral with light fixture ) . system lumen efficacy of ≥ 120 lm / watt , thd < 10 % , p.f.≥0.95, cri >80 , life time of minimum 50000 burning hours with , 70% of intial lumen maintaned till life ends , cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be of bis standard and trade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing on housing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . surface moutning minimum lumen output 3600 lm 56 providing & fixing of ip 20 led recessed / surface mounted, round / sqaure smd mid power led downlight with power coated die cast aluminum housing with uv stabilized non yellowish diffuser with bis complience 2.5 kv surge protected isolated driver, with short & open circuit protection, having efficiency > 85% . system lumen efficacy of ≥ 110 lm / watt, thd < 10 % , pf.≥0.95, cri >80, life time of minimum 50000 burning hours with , 70% of intial lumen maintaned till life ends , cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be of bis standard and trade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing on housing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . surface mounting ( with extruded alumn. housing ) minimum lumen output 1950 lm 57 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed arrmoured aluminium cable confirming to is:1554 p i / is :7098 p i of 1.1 kv with h4 grade electrolytic aluminium conductor confirming to is 8130 of purity >99.6 %, round / flat strip armouring of cables, inner / outer sheath confirming to is:5831 in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench / cable tray ( with cable tie ) including testing etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810.for additional technical parameters of product / work refer annexure a attached with this bsr. 6.0 sq. mm 4 core 58 10.0 sq. mm 4 core 59 16.0 sq. mm 4 core 60 50.0 sq. mm 3.5 core 61 supplying and making one end termination with nickel plated heavy duty brass single compression gland ( as per is 12943 1990 ) ) sibg type consisting of check nut, gland body, metal washer ( 3 nos. ) , outer seal rubber ring, compression nut, heavy duty aluminium lugs ( as per is 8309 1993 ) duly crimped with crimping tool, pvc tape as per is 8337 1976 of following size of pvc insulated & pvc sheathed / xlpe aluminium conductor cable of 1100 volt grade as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 4 x 6.0 sq.mm 62 4 x 10.0 sq.mm 63 3.5 x 50.0 sq.mm 64 sitc of ip 42 and general construction confirming to is:8623 : 1993, wall / free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point ( a ) , ( b ) , ( c ) , ( d ) , ( e ) , ( f ) , ( g ) , ( h ) as below: ( a ) thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided ( b ) complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam / neoprene rubber gasket of not less than 3mm thickness , required hardware , concealed hinged door with key type locking arrangement for equipment / switchgear earthed with 2.5 sq.mm braided copper wire. [ c ) interconnection between bus bar and switchgears / cable shall be rigidly supported and made out by flexible copper wires ( up to 63 amp ) and by solid bus bar ( >63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgear is to be paid extra ) ( d ) wiring between components within switchgear and incoming / outgoing cable shall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. ( e ) all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be ‘point to point’ ( no wire splitting or tee connections ) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. ( f ) floor mounted panel shall be mounted on base frame of ismc channel size 100 x 50 x 5 mm ( to be paid extra ) ( g ) tests: the insulation resistance ( with 1000 v megger ) and high voltage power frequency test ( by applying a voltage of 2.5kv for one minute ) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. the insulation resistance shall not be less than three megaohm. ct secondary current injection test shall also be carried out. ( h ) only outer surface area on all sides shall be measured & panel to be fabricated only from cpri approved fabricator only ( cpri test certificates to be submitted ) all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 65 supplying and fixing of aluminium ( iec 60105 iso 209 1, 2 ) / copper ( iec 60028 ) bus bar by means of smc / dmc type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . electrolytic grade aluminium bus bar 6010 grade 66 providing & fixing of is: 13875 & iec :61326 confirming led digital type ( up to 500 ) v range volt meter / direct ammeter / ct oertated ammeter / frequency meter / kwh meter / multi function meter / power analyzer of class 1 accuracy as per is : 1248 of size 96mm x 96 mm including making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . three phase ammeter with inbuilt selector switch 67 three phase voltmeter with inbuilt selector switch 68 providing & fixing of bis approved current transformer as per pwd specification for electrical works , isi marked as per is 2705 1992 / conforming to iec 60044 1, with secondary terminal of ct shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required current transformer ring type tape wound / resin cast wound as per is 16227 with, accuracy cl, ct ratio and burden as specified. isf<=5, cu cross section of secondary wire 1.5sqmm ( minimum ) , including all necessary support in existing panel including connection etc. as required . all as per pre approved by engineer in charge.all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . ring type tape wound ct c t class 1, ratio upto 150 / 5, burden 5 va 69 providing & fixing of 110 / 220 v, unibody led indicating lamp iec 60947 with integral circuit, ip 65 above panel & ip 20 terminal block, approx. body dia for panel not less then 20 mm, length min. 50mm, front led cover dia min. 29 mm, contact material phospher bronze for led, pcb contacts shall be of brass ( tin plated ) , impulse dielectric tested for 2.5 kv, rated insulation resistance shall be 100 m ohm at 500vdc including connection etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . red / yellow / green colour 70 providing & fixing of electrical insulating rubber matts as per pwd specification for electrical works, isi marked confirming to is: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 11 kv, class b 2.5 mm thick with proof voltage 22 kv ac ( rms ) and break down voltage 45 kv ac ( rms ) 71 sitc of 3 / 4 pole current limiting moulded case circuit breaker ( mccb ) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440 / 415 v, 50 hz; o / l & s / c settings , conforming to is / iec 60947 p 2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push ( test ) to trip, trip time less then 10 ms under s / c condition, breaking capacity ics = 100% icu. u imp =8 kv, rated insulation voltage 690 v. provision for uvr , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.oem shall have submit nabl / cpri / erda accrediated lab type test certificate before execution all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr. 4 pole mccb with thermal magnetic release up to 100 amp , 25 ka, adjustable o / l & adjustable s / c setting, 72 160 amp , 25 ka, adjustable o / l & adjustable s / c setting, 73 providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket / pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc ( uv stablization report submitted for uv cover ) / toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm / wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% , thd ( i ) <10% humidity 10% to 90% rh working temp 5c to 45c . driver current <750ma. the luminaire shall be bis certified and trade mark certified. life expectancy equal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min ≥ 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark / name engraved / embossing on die cast housing to allow traceability / authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 / lm80 ) certificate / report with liable warranty of product / accessories from oem shall be submitted. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . led street light fixture with minimum lumen output 3700 lm 74 providing & fixing of street light bracket made out from following size of b class , medium class g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with heavy duty pole clamp, saddles suitable fastners etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 32 mm dia. 75 sitc of single stage, water cooled, high speed ( 2880 rpm ) , horizontal, centrifugal, openwell submersible pumps set pre filled with coolent water and fitted with mechanical seal t / c vs t / c, thrust bearing shall be of carbon + s.s.the stator body of single phase pump shall be of ss and rest of all shall be of cast iron. all casting parts should be cathod electro deposition ( ced ) coated and other construction material should be confirming to is : 14220: 2018 . the overall performance of pump shall confirm to bee energy efficiency level of 3 star. valid bee certificate from oem must be submitted for the same. motor should be ie2 class as per iec 60034 2 1: 2007, iec 60034 30: 2008, & is12615:2011, including making connection etc as required complete in all respect. oem shall have submit nabl / cpri / erda accrediated lab type test certificate before execution. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 1.5 hp, 1 ø, ( 18 26 ) mtr, ( 126 78 ) lpm 76 supply & fixing of gi pipes confirming to is : 1239 p 1 ( 2004 ) with flanges duly screwed & welded including rubber washer, nuts & bolts of 8mm dia complete in all respect.all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . b class 50mm dia 77 sitc of contactor oem fabricated dol / star delta starter panel with switchgear selection as per type 2 cordinatiom chart and made out from 1.6 mm thick powder coated crca sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, illuminated on / off push buttons, ammeter, voltmeter, indicating lamps etc. suitable for following rating motors complete in all respect. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . for three phase submersible / mono block pump 3.0 hp to 5.0 hp ( star / delta starter ) 78 p / laying isi marked p.v.c. insulated submersible cable confirming to ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from 99.90 % purity copper, stranding in acc. to is:8130 / iec 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation pvc type a / c / d , flame retardant as per is 10810 53, better amperage rating as per is:3961 part 5, existing pipe / open trench / cable tray / on surface including making connection etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr. 6.0 sq.mm 3 core flat / round 79 supply, fabricating & installing following sizes of perforated hot dipped galvanized iron cable tray ( galvanized thickness not less then 50 microns ) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees, cross members and other accessories as required and duly suspended from the ceiling with gi suspenders including gi bolts & nuts , fastners, supports etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 150mm x 50mm x 1.6mm 80 p & f in position frame made out of m.s. angle ( riveted or welded ) finished with two coats of red oxide and two coats enamel paint including cutting, welding, holes etc.of following sizes as required.for additional technical parameters of product / work refer annexure a attached with this bsr. 50mm x 50mm x 6mm 81 35mm x 35mm x 5mm 82 providing & fixing of iso certified company made on load change over switch, front handle operated, four pole 415 v as per pwd specification for electrical works conforming to is / lec 60947 3 : 1999 including connections , testing etc. as required .in the following rating. appropriate type test certificate / oem test report shall be submitted . all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . open execution type 125 a 83 providing & fixing of vertical ( bee 5 star rated ) / horizontal ( bee 3 star rated ) storage water heater with outer casing made of engineering plastic sheet ( upto 25 ltr ) / metal rust proof body ( 35 & 50 ltr ) , glass line / titanium enamel coated pressure pump compatible 8 bar pressure inner tank, glass line coated , mineral filled heating element, stem type, snap action adjustable thermostat , dual indicating lamps injected puf insulation, multi function valve etc. as required held in position with 2 / 4 no. 10 / 12 mm anchor fastener, duly wired with 3 core 2.5 / 4.0 sqmm pvc insulated & sheathed copper conductor and 16 a / 25a three pin plug top with portable residual current device ( prcd ) , including making inlet, outlet flexible alloy connection, testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 15 ltr. 84 providing & fixing of vertical ( bee 5 star rated ) / horizontal ( bee 3 star rated ) storage water heater with outer casing made of engineering plastic sheet ( upto 25 ltr ) / metal rust proof body ( 35 & 50 ltr ) , glass line / titanium enamel coated pressure pump compatible 8 bar pressure inner tank, glass line coated , mineral filled heating element, stem type, snap action adjustable thermostat , dual indicating lamps injected puf insulation, multi function valve etc. as required held in position with 2 / 4 no. 10 / 12 mm anchor fastener, duly wired with 3 core 2.5 / 4.0 sqmm pvc insulated & sheathed copper conductor and 16 a / 25a three pin plug top with portable residual current device ( prcd ) , including making inlet, outlet flexible alloy connection, testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 25 ltr. 85 supply, installation, & testing of 19 1u rack mounted / surface mounted aluminum / crca 1.2mm powder coated, singlemode glass fiber optic cable patch panel / liu loaded with flangless / screwable duplex adapters for st / e 2000 / sc / lc / mt rj / pc type, it should have easy removable top plate with push buttons, there should be a splice tray installed in the patch panel / liu which can handle the fiber cores, splice tray should be pc+abs material, it should include accessories like mounting hardware, gormetts, heat shrink tubes / sleevs, screws, nuts to install the panel for rack / wallmount applications as per requirment complete in all respect. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 24 ports 86 supply , installation and testing of 4 pair, 100 ohm impedance, cat 6 / 6a / class e / ea patch cords should be constructed of minimum 23 / 24 awg, stranded bare copper cable with frpvc / lszh jacket, with an enhanced performance by factory moulded rj45 connectors with strain relief boots as per ansi / tia / eia 568 c.2 suitable for cat 6 / 6a application complying to latest ammendments category 6 / 6a standards, according. to tia568c.2, iso / iec 11801, en 50173, iec 60603 7 51, en 60603 7, ieee 802.3an minimum requirement for 1g base t to 10g base t performance. patch cords shall be straight thru cable compatible with both t568 a and t568 b wiring schemes, should support ieee 802.3af / ieee 802.3at for poe applications, minimum 750 to 1000 mating cycles in plug contacts for long durability, should support ethernet 10gbase t, 1.2 gb / s atm, token ring 4 / 16, digital video and broadband / baseband analog video, voice over internet protocal ( voip ) .all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . cat 6, u / utp ( unscreened / un sheilded twisted pair ) patch cord 1 mtr 87 supply & installation of ip 20 & ik 08 , ul listed wall mounted double section communication enclosure ( rack ) made from powder coated ( 60 to 80 micron ) crca sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door, vertical mounting rail 1.6 mm with umarking , with all round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. accessories like: 1 no of 19 1u horizontal cable manager, 1 no of 90 cfm 230v ac fan with 1 mts long cable, mounting hardware , 1 no of 19 1u, mountable socket strips with 5 nos of 5a universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with suitable anchor fastner etc as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 12 u rack with width 600 mm & depth 400 mm + 100 mm 88 supply , installation, testing and comissioning of managed layer 2 intelligent 10 / 100 ethernet switch providing 24 x 10 / 100 / 1000 mbps giga ethernet ports / with min 2 sfp giga ports ( provision for fiber giga connectivity ) with related lan base software including making connections etc as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 89 supply , installation, testing and comissioning of inverter type air cooled hi wall split type air conditioners with latest star rating system as per bee amended upto date complete with indoor unit ( idu ) , out door unit ( odu ) , surface / concealed copper refrigerant piping with insulation ( closed cell elastomeric nitrile rubber tubular pipe section ) upto 3 mtr ( idu to odu ) , copper power cable upto 3.5 mtr ( idu to odu ) , r 32 / r 410 green refrigerant, wireless remote control, suitable for working between 230v + / 10% with low & high voltage cutoff and 50 hz , single phase ac supply capable of performing cooling, dehumidification, air circulation of following capacity with scroll / rotary compressor. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 1.5 tr iseer not less then 3.8 90 supply, fixing and testing of following capacity iso certified company made wall mounted stabilizer having output voltage variation from 200 v to 250 v ( + / 5% ) with input voltage variation from 170 v to 260 v, time delay facility from 2 to 4 minute and high cutoff at 270 v with providing of 16 amp / 20 amp industrial plug top making connection etc complete in all respect. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 4 kva 91 supply & fixing ms powder coated stand suitable for 1.0 / 1.5 / 2.0 tr outdoor type of split ac. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 92 supply , installation, testing and comissioning of is:1475 marked self contained drinking water cooler with hermetically sealed compressor, non cfc refrigerent suitable for operation on 230v / 1ph / 50hz ac supply, full stainless steel ( ss304 ) body ( 0.8 mm thick ) and tank ( 0.5 mm thick ) , stainless steel water tray, minimum two nos brass chrome plated faucets and suitable drainage system complete in all respect with required height ms fabricated and painted angle iron frame ( cost of frame to be paid extra ) complete in all respect of the following capacity. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . cooling capacity 150 ltr. / hr. and storage capacity 150 ltrs 93 supply & fixing of dry powder agent ( as per is 4308:2019 ) , abc type fire extinguisher ( stored pressure type ) conforming to is:15683:2018 , powder coated internal & external surface deep drawn cylinder body of mild steel cr2 grade conforming to is: 513, squeeze grip forged brass release valve with inbuilt safety release device, diaphragm type, 0 to 28 bar range pressure gauge, 450 mm long epdm discharge tube, qr code for product traceability including fixing on wall with suitable anchor fasteners as required of following capacity. test certificates of all the parameters along with hydro test & burst test ( for cylinder body ) certificate from oem / external nabl accrediated lab is to be submitted. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 4 kg 94 p & f in position frame made out of m.s. angle ( riveted or welded ) finished with two coats of red oxide and two coats enamel paint including cutting, welding, holes etc.of following sizes as required.for additional technical parameters of product / work refer annexure a attached with this bsr. 40mm x 40mm x 5mm 95 p & f of industrial plug and socket conforming to iec 60309 1 / 2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. for additional technical parameters of product / work refer annexure a attached with this bsr. ip 67 surface / wall mounted socket. 32 a 3 pin ( 2p+e ) ...

Medical Health And Family Welfare - Rajasthan

36433514 electrical work in the construction of phc building at badka ( laxmangarh ) distt. alwar wiring of light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked mms ( is:9537 p iii ) virgin material pvc conduit & itsisi marked ( is:3419 1988 ) accessories, round tiles, 1.2 mm thickhot dipped galvanized modular box with earth terminal, 10a modular switch, modular face plate with grid plate, 3 pin ceiling rose / holder / 3 way connector, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 3 short point ( up to 3 mtr. ) 4 medium point ( up to 6 mtr. ) 5 long point ( up to 10 mtr. ) 6 wiring of twin control light point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) in recessed isi markedmms ( is:9537 p iii ) pvc conduit & its isi marked ( is:3419 1988 ) accessories, round tiles, 2 nos hot dipped galvanized m.s modularbox of 1.2 mm thickwith earth terminal, 2 nos10 a two way modular switch, 3 pin ceiling rose / holder / 3 way connector , modular face plate with grid plate, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 7 medium point ( up to 6 mtr. ) 8 long point ( up to 10 mtr. ) 9 wiring of 3 / 5 pin 6 amp. light plug point with 1.5 sq. mm nominal sizefr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked mms ( is:9537 p iii ) pvc conduit & its isi marked ( is:3419 1988 ) accessories, hot dipped galvanizedmodular box of 1.2 mm thick with earth terminal, 10 a modularswitch, 3 / 5 pin 6 a modular socket, modular face plate with grid plate, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 10 on board 11 s&f following sizes ( dia. ) of isi marked virgin material mms ( is:9537 p iii ) pvc conduit along withisi marked ( is:3419 1988 ) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. for additional technical parameters of product / work refer annexure a attached with this bsr 12 20 mm 13 25 mm 14 32 mm 15 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from99.90 % purity copper, class 5 stranding in acc. to is:8130 / iec 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation pvc type a / c / d , flame retardant as per is 10810 53, better amperage rating as per is:3961 part 5, in existingsurface or recessed pvc / ms conduit / casing capping making connections with copper lugs of suitable size, ferrules, testing etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of product / work refer annexure a attached with this bsr 16 1 x 1.5 sq.mm 17 3x 1.5 sq.mm 18 2 x 2.5 sq. mm. + 1x1.5sqmm 19 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 20 4 x 10.0 sq.mm 21 4 x 6.0 sq.mm 22 1 x 4.0 sq.mm 23 1 x 2.5 sq.mm 24 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. 25 supplying and drawing pe insulated & pvc sheathed unarmoured telephone cable with 0.5 mm dia. solid annealed electrolytic grade bare copper conductor as per is: 8130 / 84 &confirming to tec specification gr / wir / 06 03 march 2002in existingsurface or recessed conduit / casing capping. including ferruling on each pair for identification etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 26 2 pair 27 p & f in position frame made out of m.s. angle ( riveted or welded ) finished with two coats of red oxide and two coats enamel paint including cutting, welding, holes etc.of following sizes as required.for additional technical parameters of product / work refer annexure a attached with this bsr 28 40mm x 40mm x 5mm 29 p & f paper phenolic resin bondedlaminates confirming to is : 2036 1995 for boxes / frames including making holes for switches etc, with brass screws, washers / zinc platednut and bolts as required. for additional technical parameters of product / work refer annexure a attached with this bsr 30 6.4 mm thick 31 p & f phenolic laminated sheet 2.0 mm thick of following size . including screws, cup washer as required.for additional technical parameters of product / work refer annexure a attached with this bsr 32 75 mm dia 33 providing & fixing of 240 / 415 v ac mcb with positive isolation of 10 ka breaking capacity ( b / c / d tripping characteristic as per type of load andsite requirement ) 4 kv impulse withstand voltage, isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted inexisting distribution board / sheets, minimum electrical operation 20, 000 upto 20 a rating and 10, 000 upto 63 a, 5000 for 80 a & above ratingincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 34 single pole mcb ( with b / c curve tripping characteristics ) 35 6 a to 32 a rating 36 double pole mcb ( with b / c curve tripping characteristics ) 37 6 a to 32 a rating 38 four pole mcb ( with b / c curve tripping characteristics ) 39 6 a to 32 a rating 40 50 / 63 a rating 41 providing & fixing of recessed / surface mounting heavy duty horizontal type double door ( metal / glazed ) distribution board with metal end box made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3, powder painted complete with reversible door ( for double door db only ) 100 amp. insulated copper bus bar / shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar, masking sheet, making internal db terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 42 metal door ( single phase ) ik 09 and ip 43 with metal end box 43 16 way ( 16+2 ) 44 metal door ( three phase ) ik 09 and ip 43with metal end box 45 6 way 46 p&f metal clad / plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain / bakelite base in recessed / surface mounting heavy duty enclosure made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3. powder painted ( without mcb ) including making connections, testing etc.as required.for additional technical parameters of product / work refer annexure a attached with this bsr 47 20 amp, 3 pin + scrapping earth, 4 module 48 p & f of industrial plug and socket conforming to iec 60309 1 / 2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. for additional technical parameters of product / work refer annexure a attached with this bsr 49 ip 67 panel mounted socket 50 32 a 3 pin ( 2p+e ) 51 providing & fixing of flush typenon modular single line telephone jackmade out fromindustrial grade polycarbonate or fire resistant abs material, including making connection testing etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 52 providing & fixing of ding dong / musical chime bell as per pwd specification for electrical works, including making connection testing etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 53 providing & fixing of modular type 120 w step fan regulator duly isi marked ( is 11037:1984 ) with cm / l no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , includingall as per pre approved by engineer in charge, making connections, testing etc. as required.for additional technical parameters of product / work refer annexure a attached with this bsr 54 5 step fan regulator 2 module 360 dgree rotating 55 supplying and fixing of power plug point with modular accessories as per pwd specification for electrical works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal / connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofisi marked modular 16 amp. switch ( is :3854 ) and 6 / 16 amp. socket outlet ( is:1293 ) making connection , testing , etc. as required. for specification ofwiring accessories refer chaptere 07related item & for additional technical parameters of product / work refer annexure a attached with this bsr 56 p & f krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted, including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 57 10 pairs 58 sitc of ip 42 and general construction confirming to is:8623 : 1993, wall / free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andother parameters requiredas per point ( a ) , ( b ) , ( c ) , ( d ) , ( e ) , ( f ) , ( g ) , ( h ) as below: 59 ( a ) thickness of crca sheet shallbe 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 60 ( b ) complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel.the panel having pe foam / neoprene rubber gasket of not less than 3mm thickness , required hardware , concealed hinged door with key type locking arrangement for equipment / switchgear earthed with 2.5 sq.mm braided copper wire. 61 [ c ) interconnection between bus bar and switchgears / cable shall be rigidly supported and made out by flexible copper wires ( up to 63 amp ) and by solid bus bar ( >63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only.all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgearis to be paid extra ) 62 ( d ) wiring between components within switchgear and incoming / outgoing cableshall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 63 ( e ) all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be ‘point to point’ ( no wire splitting or tee connections ) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 64 ( f ) floor mounted panel shall be mounted on base frame of ismcchannel size 100 x 50 x 5 mm ( to be paid extra ) 65 ( g ) tests: the insulation resistance ( with 1000 v megger ) and high voltage power frequency test ( by applying a voltage of 2.5kv for one minute ) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. the insulation resistance shall not be less than three megaohm. ct secondary current injection test shall also be carried out. 66 ( h ) only outer surface area on all sides shall be measured & panel to be fabricated only from cpri approved fabricator only ( cpri test certificates to be submitted ) all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 67 supplying and fixing of aluminium ( iec 60105 iso 209 1, 2 ) / copper ( iec 60028 ) bus bar by means of smc / dmc type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 68 electrolytic grade aluminium bus bar 6010 grade 69 providing & fixing of bis approvedcurrent transformeras per pwd specification for electrical works , isi marked as peris 2705 1992 / conforming to iec 60044 1, with secondary terminalof ct shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredcurrent transformer ring type tape wound / resin cast wound as per is 16227 with, accuracy cl, ct ratio and burden as specified. isf<=5, cu cross section of secondary wire 1.5sqmm ( minimum ) , including all necessary support in existing panel including connection etc. as required . all as per pre approved by engineer in charge.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 70 ring type tape wound ct 71 c t class 1, ratio 200 / 5 to 300 / 5, burden 10 va 72 providing & fixing of110 / 220 v, unibody led indicatinglamp iec 60947with integral circuit, ip 65 above panel &ip 20 terminal block, approx. body dia for panel not less then 20 mm, length min. 50mm, front led cover dia min.29 mm, contact material phospher bronze for led, pcb contacts shall be ofbrass ( tin plated ) , impulsedielectric tested for 2.5 kv, rated insulation resistance shall be 100 m ohm at 500vdcincluding connection etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 73 red / yellow / green colour 74 providing & fixing of electricalinsulating rubber matts as per pwd specification for electrical works, isi marked confirming to is: 15652 / 2006with one sideanti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 75 3.3 kv, class a 2 mm thick with proof voltage 10 kv ac ( rms ) and break down voltage 30 kv ac ( rms ) 76 sitc of3 / 4pole current limiting moulded case circuit breaker ( mccb ) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440 / 415 v, 50 hz; o / l & s / c settings , conforming to is / iec 60947 p 2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push ( test ) to trip, trip time less then 10 ms under s / c condition, breaking capacity ics = 100% icu. u imp =8 kv, rated insulation voltage690 v.provision for uvr , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.oem shall have submitnabl / cpri / erda accrediated lab type test certificate before execution all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 77 4 pole mccb with thermal magnetic release 78 125 amp , 25 ka, adjustable o / l & adjustable s / c setting, 79 up to 100 amp , 25 ka, adjustable o / l & adjustable s / c setting, 80 providing & fixing of iso certified company made on load change over switch, front handle operated, four pole 415 v as per pwd specificationfor electrical works conforming to is / lec 60947 3 : 1999 including connections , testing etc. as required .in the following rating.appropriate type test certificate / oem test report shall be submitted .all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 81 open execution type 82 160 a 83 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed arrmouredaluminiumcable confirming to is:1554 p i / is :7098 p i of 1.1 kv withh4 grade electrolyticaluminium conductor confirming to is 8130 of purity >99.6 %, round / flat strip armouring of cables, inner / outer sheath confirming to is:5831in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench / cable tray ( with cable tie ) includingtesting etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810.for additional technical parameters of product / work refer annexure a attached with this bsr 84 10.0 sq. mm 85 2 core 86 35.0 sq. mm 87 3.5 core 88 supplying and making one end termination with nickel plated heavy duty brass single compression gland ( as per is 12943 1990 ) ) sibg type consisting of check nut, gland body, metal washer ( 3 nos. ) , outer seal rubber ring, compression nut, heavy duty aluminium lugs ( as per is 8309 1993 ) duly crimped with crimping tool, pvc tape as peris 8337 1976offollowing size ofpvc insulated & pvc sheathed / xlpe aluminium conductor cable of 1100 volt grade as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 89 3.5 x 35.0 sq.mm 90 supplying and makingend termination with heavy aluminiumlugs ( pin / ring type ) confirming to is 8309 1993 & is 8337 1976 duly crimped with crimping tool, pvc tape etc of following size.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 91 35.0 sq.mm 92 supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % copperthickness ( 250 microns ) andconfirming toul 467, is / iec 62561 2of following size and length and as per point mentioned ( a ) , ( b ) , [ c ) , ( d ) , ( e ) below : 93 ( a ) bore a hole of dia. 100 mm of required length, place the rod in the centre of hole 94 ( b ) filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, cpri / erdatested with rms capacity of minimum 30 ka for withstanding 1 second .to ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. the compound shall be tested form nabl acredeated labfor lowresistivity ( less than 0.12 ohm meter ) & high conductivity in nature with carbon as a major contentas per referance of is 3043 1987, ieee 80 2013 ( clause 14.5d ) , ieee 837 & ier 1956 with latest amendemnts 95 © connect the rod with copper strip / conductor / wire with suitable clamp made from tinned copper and ss 304 bolt 96 ( d ) place heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height250 to 300 mm. 97 ( d ) testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 98 ( e ) test certificatesfor confirming above standards from oem is mandatory. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 99 17.2 mm thick and 3 mtr. long 100 supply & laying following size earth wire in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection with gi / cu purity purity >95%thimble etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 101 8 swg copper wire 102 8 swg g.i. ( hot dipped ) wire 103 making of hole in wall ( brick / stone ) of required and placing np 2 rcc pipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 104 up to 457 mm size 105 providing & fixing ofbeestar rated copper wounded double ball bearing capacitor start, aluminium body & metallicblade ceilingfanconforming to all the performance requirements laid down in is 374:2019 including all amendments, as applicable ; & carry bis licensing ( i.e. isi marking ) with down rod up to 80 cm with secondary support safety cable ( steel rope ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 106 1200 mm sweep bee 2 star rated ( service value >=4.5 to < 5 ) 107 1200 mm sweep bee 3 star rated ( service value >=5.0 to< 5.5 ) 108 p & f 1.2mm thickm.s. recessed fan box, hexagonal / round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mmlength extended on each side . all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr 109 p & f 1.2mm thickm.s. recessed fan box, hexagonal / round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mmlength extended on each side . all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr 110 providing & fixing ofof double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor , making connections, testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 111 225 mm sweep 112 providing & fixing of heavy duty capacitor start, copper wounddouble ball bearing900 / 1400 rpm single phaseexhaustfan conforming to is:2312 isi marked in existing opening including making connections testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 113 300 mm sweep ( 900 / 1400 rpm ) 114 providing & fixing of wall mounting / pedestal type heavy duty air circulator , double ball bearing and with metal sturdy mesh guard; aluminium alloy one piece blade and conforming to is:2997, including fixing with anchor bolts, making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 115 450 mm sweep wall mounting and three speed regulator with minimum air delivery 150 cum. / minute 116 p & f of gravity louver shutter of superior quality made out of frame of18 swg m.s. sheet & louvers made from 24 swg ms sheetwith enamel paint including cost of nuts, bolts, etc as reqd.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 117 up to 380 mm size 118 providing & fixing of vertical ( bee 5 star rated ) / horizontal ( bee 3 star rated ) storage water heater with outer casing made of engineering plastic sheet ( upto 25 ltr ) / metal rust proof body ( 35 & 50 ltr ) , glass line / titanium enamel coated pressure pump compatible 8 bar pressure inner tank, glass line coated , mineral filled heating element, stem type, snap actionadjustable thermostat , dual indicating lampsinjected puf insulation, multi function valve etc. as required held in position with 2 / 4 no. 10 / 12 mm anchor fastener, duly wired with 3 core 2.5 / 4.0 sqmm pvc insulated & sheathed copper conductor and 16 a / 25a three pin plug top with portable residual current device ( prcd ) , including making inlet, outlet flexible alloyconnection, testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 119 15 ltr. 120 sitc ofmnre approved & confirming to is:12933 p 1, 2, 3 & 5 flat plate collector type solar hot water system havingcollector withzincalum sheet outer body , glass line / titanium enamel coated inner tank with metal rust proof puf insulated body includingelectrical back up, thermostat, powder coated / hot dipped galvanized ms standfor collector & tank etc. as required. of following capacity complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 121 200 litre / day 122 providing & fixing of energy efficient direct fit ( retrofit ) polycarbonate / glasshousingsmd mid power led tube rod ( with integral driver & alumn. heat sink ) , on existing fixture.system lumen efficacy = 100 lm / watt output, internal surge protection of 2.5 kv , thd < 20% , p.f.=0.95, cri >80 , life time of minimum35000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 123 1200mm , min. lumens output 2000 lmled tube rod with polycarbonate housing 124 providing & fixing of ip 20 led recessed / surface mounted, round / sqauresmd mid power led downlight with power coated die cast aluminum housingwith uv stabilized non yellowish diffuser withbis complience 2.5 kv surge protected isolated driver, with short & open circuit protection, having efficiency > 85% . system lumen efficacy of = 110 lm / watt, thd < 10 % , pf.=0.95, cri >80, life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. 125 oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 126 surface mounting ( with extruded alumn. housing ) 127 minimum lumen output 1950 lm 128 providing & fixing of ip20, 2x2 led surface / recessedmounting mid power smd type led light fixture not less than 50mm housing depth made from crca sheet steel housing, high purity / transmisivity uv stabilized non yellowish diffuser for uniform light distribution. high efficiency with 4 kv internal / external surge protection bis certified isolated driver having efficiency > 85% , with short & open circuit protection ( integral with light fixture ) . system lumen efficacy of = 120 lm / watt , thd < 10 % , p.f.=0.95, cri >80 , life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. 129 oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 130 recessed mounting 131 minimum lumen output 4200 lm 132 providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket / pole. fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with uv stabilized pc ( uv stablization report submitted for uv cover ) / toughened glass coverand secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm / wt and potted driver& has a unique bis r number withinput voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driverefficiency >85%, thd ( i ) <10%humidity 10% to 90% rh working temp 5c to 45c .driver current <750ma. the luminaireshall be bis certified and trade mark certified. life expectancyequal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min = 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs.manufactures word mark / name engraved / embossing on die cast housing to allow traceability / authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities forled fixtures. ( lm79 / lm80 ) certificate / report with liable warranty of product / accessories from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 133 led street light fixture with minimum lumen output 2450 lm 134 providing & fixing of street light bracket made out from following size of b class , medium class g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with heavy duty pole clamp, saddles suitable fastners etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 135 25 mm dia. 136 supply, drawing and testing of 4 pair, 23 awg solid bare copper wire insulated with pvc, utp ( unshielded twisted pair ) , category 6, class e, 100 ohm impedance, indoor cable as per latest ammendments of ansi / tia / eia 568 , the copper conductors should be balanced twisted in pairs, seperated by a cross member fluted pair divider & protected bypvc jacket. certified performance in a 4 connector configuration upto 100 mtrs channel requirements & transmission frequencies up to 250 mhz. in existing ms / pvc conduits / casing capping including making connections to information outlets and patch panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 137 supply and installation of unsheilded / 360 degree sheilded information outlets made of high impact plastic body with abs, fr grade halogen free material with provision for protection against dust in jack, suitable for cat 6 / 6a application complying to latest ammendments, according. to cat. 6 / 6a channel, it should support channel as well as components requirements of cat.6 / 6a standards at frequencies of up to 250 to 500 mhz. cat 6 / 6a unshielded / shielded jack should be suitable to terminate 4 pair, 23 / 24 awg solid / stranded wire diameters, using 100 ohm unshielded / shielded balance twisted pair cable, the jack should have tooless / impact termination on reliable copper tin plated insulation displacement contact, with easy lock mechanism, it supports iec 60603 7 4 and complied with ansi / tia / eia 568 c.2 standard. jack should be rj11, rj12 & rj45 compatible. should support ethernet 1.2 gb / s atm, digital video and broadband / baseband analog video, voice over internet protocal ( voip ) specifications in existing modular / ms boxes along with necessory connections as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 138 cat 6, un sheilded information outlet 139 supply & fixing of square faceplate for flush / surface mount information outlets single / dual or quad aperture , material should bepc+abs body, suitable for rj45 unshielded / shielded connection modules. should match with i. o. oem. dimensions should be 86mm x 86mm as required complete in all respect.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 140 single aperture 141 supply , installation and testing of 4 pair, 100 ohm impedance, cat 6 / 6a / class e / ea patch cords should be constructed of minimum 23 / 24 awg, stranded bare copper cable with frpvc / lszh jacket, with an enhanced performance by factory moulded rj45 connectors with strain relief boots as per ansi / tia / eia 568 c.2 suitable for cat 6 / 6a application complying to latest ammendments category 6 / 6a standards, according. to tia568c.2, iso / iec 11801, en 50173, iec 60603 7 51, en 60603 7, ieee 802.3an minimum requirement for 1g base t to 10g base t performance. patch cords shall be straight thru cable compatible with both t568 a and t568 b wiring schemes, should support ieee 802.3af / ieee 802.3at for poe applications, minimum 750 to 1000 mating cycles in plug contacts for long durability, should support ethernet 10gbase t, 1.2 gb / s atm, token ring 4 / 16, digital video and broadband / baseband analog video, voice over internet protocal ( voip ) .all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 142 cat 6, u / utp ( unscreened / un sheilded twisted pair ) patch cord 143 1 mtr 144 supply, installation, & testing of 19 1u rack mounted / surface mounted aluminum / crca 1.2mm powder coated, multimode glass fiber optic cable patch panel / liu loaded with flangless / screwable adapters for st / e 2000 / sc / lc / mt rj / pc type, it should have easy removable top plate with push buttons, there should be a splice tray installed in the patch panel / liu which can handle the fiber cores, splice tray should be pc+abs material, it should include accessories like mounting hardware, gormetts, heat shrink tubes / sleevs, screws, nuts to install the panel for rack / wallmount applications as per requirement complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 145 multi mode liu 12 ports 146 supply & installation of ip 20 & ik 08 , ul listedwall mounted double section communication enclosure ( rack ) made from powder coated ( 60 to 80 micron ) crca sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door, vertical mounting rail 1.6 mm with umarking , with all round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. accessories like: 1 no of 19 1u horizontal cable manager, 1 no of 90 cfm 230v ac fan with 1 mts long cable, mounting hardware , 1 no of 19 1u, mountable socket strips with 5 nos of 5a universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with suitable anchor fastneretc as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 147 6 u rack with width 600 mm &depth 400 mm + 100 mm 148 supply , installation, testing and comissioning ofmanaged layer 2 intelligent 10 / 100 ethernet switch providing 24 x 10 / 100 / 1000 mbps giga ethernet ports / with min 2 sfp giga ports ( provision for fiber giga connectivity ) with related lan base software including making connections etc as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 149 sitc of single stage, water cooled, high speed ( 2880 rpm ) , horizontal, centrifugal, openwell submersible pumps set pre filled with coolent water and fitted with mechanical seal t / c vs t / c, thrust bearing shall be ofcarbon + s.s.the stator body of single phase pumpshall be of ss and rest of all shall be of cast iron. all casting parts should be cathod electro deposition ( ced ) coated and other construction material should be confirming to is : 14220: 2018 . the overall performance of pump shall confirm to bee energy efficiency level of 3 star. valid bee certificate from oem must be submitted for the same. motor should be ie2 class as per iec 60034 2 1: 2007, iec 60034 30: 2008, & is12615:2011, including making connection etc as required complete in all respect. oem shall have submitnabl / cpri / erda accrediatedlab type test certificate before execution. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 150 1.0 hp, 1 ø, ( 7 12 ) mtr, ( 405 240 ) lpm 151 sitc of monoblock motor pump set isi marked ( is:9079 2002 ) with tefc motor, motor should be ie2 class as per iec 60034 2 1: 2007, iec 60034 30: 2008, & is12615:2011. with stainless steel impellor, stainless steel shaft, mechanical seal, single / three phase ( 240 440 v ) permanent split capacitor type ( psc ) , fitted with thermal overload protection, including cost of hardware etc on existing platform complete. pump shall have following hp rating, phase, head, minimum discharge respectively complete in all respect. oem shall have submitnabl / cpri / erda accrediatedlab type test certificate before execution. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 152 1.0 hp, 1 ø, ( 10 120 ) mtr, ( 30 12 ) lpm 153 supply , installation, testing and comissioning ofinverter type air cooled hi wall split type air conditioners with latest star rating system as per bee amended upto date complete with indoor unit ( idu ) , out door unit ( odu ) , surface / concealed copper refrigerant piping with insulation ( closed cell elastomeric nitrile rubber tubular pipe section ) upto 3 mtr ( idu to odu ) , copper power cable upto 3.5 mtr ( idu to odu ) , r 32 / r 410 green refrigerant, wireless remote control, suitable for working between 230v + / 10% with low & high voltage cutoff and50 hz , single phaseacsupply capable of performing cooling, dehumidification, air circulation of following capacity with scroll / rotary compressor. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 154 1.5 tr iseer not less then 3.8 155 providing & fixing of is : 4985 2000 class 4 ( 10 kgf / sqcm ) upvc drain water piping withfittings ( is:7834 & 10kgf / sqcm ) like elbow, socket, tee, solvent cement jointing, support with ms hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following nominal sizes. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 156 25 mm 157 supply, fixing and testing of following capacity iso certified company made wall mounted stabilizer having output voltage variation from 200 v to 250 v ( + / 5% ) with input voltage variation from 170 v to 260 v, time delay facility from 2 to 4 minute and high cutoff at 270 v with providing of 16 amp / 20 amp industrialplug top making connection etc complete in all respect.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 158 4 kva 159 making hole in stone masonary / rcc wall / rcc slab with core cutter for accomodating refrigerant pipe / drain pipe / ms pipe / cables etc of following dia 160 150 mm dia per running inch length 161 supply & fixing ms powder coated stand suitable for 1.0 / 1.5 / 2.0 tr outdoor type of split ac.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 162 supply & fixing of dry powder agent ( as per is 4308:2019 ) , abc typefire extinguisher ( stored pressure type ) conforming to is:15683:2018 , powder coated internal & external surface deep drawn cylinder body of mild steel cr2 grade conforming to is: 513, squeeze grip forged brass release valve with inbuilt safety release device, diaphragm type, 0 to 28 bar range pressure gauge, 450 mm long epdm discharge tube, qr code for product traceability including fixing on wall with suitable anchor fasteners as required of following capacity. test certificates of all the parameters along with hydro test & burst test ( for cylinder body ) certificatefrom oem / external nabl accrediated lab is to be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 163 4 kg...

Medical Health And Family Welfare - Rajasthan

36432928 electrical work in the construction of phc building at duhar chougan ( thanagazi ) distt. alwar wiring of light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked mms ( is:9537 p iii ) virgin material pvc conduit & itsisi marked ( is:3419 1988 ) accessories, round tiles, 1.2 mm thickhot dipped galvanized modular box with earth terminal, 10a modular switch, modular face plate with grid plate, 3 pin ceiling rose / holder / 3 way connector, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 3 short point ( up to 3 mtr. ) 4 medium point ( up to 6 mtr. ) 5 long point ( up to 10 mtr. ) 6 wiring of twin control light point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) in recessed isi markedmms ( is:9537 p iii ) pvc conduit & its isi marked ( is:3419 1988 ) accessories, round tiles, 2 nos hot dipped galvanized m.s modularbox of 1.2 mm thickwith earth terminal, 2 nos10 a two way modular switch, 3 pin ceiling rose / holder / 3 way connector , modular face plate with grid plate, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 7 medium point ( up to 6 mtr. ) 8 long point ( up to 10 mtr. ) 9 wiring of 3 / 5 pin 6 amp. light plug point with 1.5 sq. mm nominal sizefr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked mms ( is:9537 p iii ) pvc conduit & its isi marked ( is:3419 1988 ) accessories, hot dipped galvanizedmodular box of 1.2 mm thick with earth terminal, 10 a modularswitch, 3 / 5 pin 6 a modular socket, modular face plate with grid plate, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 10 on board 11 s&f following sizes ( dia. ) of isi marked virgin material mms ( is:9537 p iii ) pvc conduit along withisi marked ( is:3419 1988 ) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. for additional technical parameters of product / work refer annexure a attached with this bsr 12 20 mm 13 25 mm 14 32 mm 15 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from99.90 % purity copper, class 5 stranding in acc. to is:8130 / iec 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation pvc type a / c / d , flame retardant as per is 10810 53, better amperage rating as per is:3961 part 5, in existingsurface or recessed pvc / ms conduit / casing capping making connections with copper lugs of suitable size, ferrules, testing etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of product / work refer annexure a attached with this bsr 16 1 x 1.5 sq.mm 17 3x 1.5 sq.mm 18 2 x 2.5 sq. mm. + 1x1.5sqmm 19 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 20 4 x 10.0 sq.mm 21 4 x 6.0 sq.mm 22 1 x 4.0 sq.mm 23 1 x 2.5 sq.mm 24 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. 25 supplying and drawing pe insulated & pvc sheathed unarmoured telephone cable with 0.5 mm dia. solid annealed electrolytic grade bare copper conductor as per is: 8130 / 84 &confirming to tec specification gr / wir / 06 03 march 2002in existingsurface or recessed conduit / casing capping. including ferruling on each pair for identification etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 26 2 pair 27 p & f in position frame made out of m.s. angle ( riveted or welded ) finished with two coats of red oxide and two coats enamel paint including cutting, welding, holes etc.of following sizes as required.for additional technical parameters of product / work refer annexure a attached with this bsr 28 40mm x 40mm x 5mm 29 p & f paper phenolic resin bondedlaminates confirming to is : 2036 1995 for boxes / frames including making holes for switches etc, with brass screws, washers / zinc platednut and bolts as required. for additional technical parameters of product / work refer annexure a attached with this bsr 30 6.4 mm thick 31 p & f phenolic laminated sheet 2.0 mm thick of following size . including screws, cup washer as required.for additional technical parameters of product / work refer annexure a attached with this bsr 32 75 mm dia 33 providing & fixing of 240 / 415 v ac mcb with positive isolation of 10 ka breaking capacity ( b / c / d tripping characteristic as per type of load andsite requirement ) 4 kv impulse withstand voltage, isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted inexisting distribution board / sheets, minimum electrical operation 20, 000 upto 20 a rating and 10, 000 upto 63 a, 5000 for 80 a & above ratingincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 34 single pole mcb ( with b / c curve tripping characteristics ) 35 6 a to 32 a rating 36 double pole mcb ( with b / c curve tripping characteristics ) 37 6 a to 32 a rating 38 four pole mcb ( with b / c curve tripping characteristics ) 39 6 a to 32 a rating 40 50 / 63 a rating 41 providing & fixing of recessed / surface mounting heavy duty horizontal type double door ( metal / glazed ) distribution board with metal end box made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3, powder painted complete with reversible door ( for double door db only ) 100 amp. insulated copper bus bar / shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar, masking sheet, making internal db terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 42 metal door ( single phase ) ik 09 and ip 43 with metal end box 43 16 way ( 16+2 ) 44 metal door ( three phase ) ik 09 and ip 43with metal end box 45 6 way 46 p&f metal clad / plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain / bakelite base in recessed / surface mounting heavy duty enclosure made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3. powder painted ( without mcb ) including making connections, testing etc.as required.for additional technical parameters of product / work refer annexure a attached with this bsr 47 20 amp, 3 pin + scrapping earth, 4 module 48 p & f of industrial plug and socket conforming to iec 60309 1 / 2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. for additional technical parameters of product / work refer annexure a attached with this bsr 49 ip 67 panel mounted socket 50 32 a 3 pin ( 2p+e ) 51 providing & fixing of flush typenon modular single line telephone jackmade out fromindustrial grade polycarbonate or fire resistant abs material, including making connection testing etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 52 providing & fixing of ding dong / musical chime bell as per pwd specification for electrical works, including making connection testing etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 53 providing & fixing of modular type 120 w step fan regulator duly isi marked ( is 11037:1984 ) with cm / l no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , includingall as per pre approved by engineer in charge, making connections, testing etc. as required.for additional technical parameters of product / work refer annexure a attached with this bsr 54 5 step fan regulator 2 module 360 dgree rotating 55 supplying and fixing of power plug point with modular accessories as per pwd specification for electrical works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal / connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofisi marked modular 16 amp. switch ( is :3854 ) and 6 / 16 amp. socket outlet ( is:1293 ) making connection , testing , etc. as required. for specification ofwiring accessories refer chaptere 07related item & for additional technical parameters of product / work refer annexure a attached with this bsr 56 p & f krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted, including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 57 10 pairs 58 sitc of ip 42 and general construction confirming to is:8623 : 1993, wall / free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andother parameters requiredas per point ( a ) , ( b ) , ( c ) , ( d ) , ( e ) , ( f ) , ( g ) , ( h ) as below: 59 ( a ) thickness of crca sheet shallbe 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 60 ( b ) complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel.the panel having pe foam / neoprene rubber gasket of not less than 3mm thickness , required hardware , concealed hinged door with key type locking arrangement for equipment / switchgear earthed with 2.5 sq.mm braided copper wire. 61 [ c ) interconnection between bus bar and switchgears / cable shall be rigidly supported and made out by flexible copper wires ( up to 63 amp ) and by solid bus bar ( >63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only.all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgearis to be paid extra ) 62 ( d ) wiring between components within switchgear and incoming / outgoing cableshall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 63 ( e ) all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be ‘point to point’ ( no wire splitting or tee connections ) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 64 ( f ) floor mounted panel shall be mounted on base frame of ismcchannel size 100 x 50 x 5 mm ( to be paid extra ) 65 ( g ) tests: the insulation resistance ( with 1000 v megger ) and high voltage power frequency test ( by applying a voltage of 2.5kv for one minute ) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. the insulation resistance shall not be less than three megaohm. ct secondary current injection test shall also be carried out. 66 ( h ) only outer surface area on all sides shall be measured & panel to be fabricated only from cpri approved fabricator only ( cpri test certificates to be submitted ) all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 67 supplying and fixing of aluminium ( iec 60105 iso 209 1, 2 ) / copper ( iec 60028 ) bus bar by means of smc / dmc type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 68 electrolytic grade aluminium bus bar 6010 grade 69 providing & fixing of bis approvedcurrent transformeras per pwd specification for electrical works , isi marked as peris 2705 1992 / conforming to iec 60044 1, with secondary terminalof ct shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredcurrent transformer ring type tape wound / resin cast wound as per is 16227 with, accuracy cl, ct ratio and burden as specified. isf<=5, cu cross section of secondary wire 1.5sqmm ( minimum ) , including all necessary support in existing panel including connection etc. as required . all as per pre approved by engineer in charge.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 70 ring type tape wound ct 71 c t class 1, ratio 200 / 5 to 300 / 5, burden 10 va 72 providing & fixing of110 / 220 v, unibody led indicatinglamp iec 60947with integral circuit, ip 65 above panel &ip 20 terminal block, approx. body dia for panel not less then 20 mm, length min. 50mm, front led cover dia min.29 mm, contact material phospher bronze for led, pcb contacts shall be ofbrass ( tin plated ) , impulsedielectric tested for 2.5 kv, rated insulation resistance shall be 100 m ohm at 500vdcincluding connection etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 73 red / yellow / green colour 74 providing & fixing of electricalinsulating rubber matts as per pwd specification for electrical works, isi marked confirming to is: 15652 / 2006with one sideanti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 75 3.3 kv, class a 2 mm thick with proof voltage 10 kv ac ( rms ) and break down voltage 30 kv ac ( rms ) 76 sitc of3 / 4pole current limiting moulded case circuit breaker ( mccb ) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440 / 415 v, 50 hz; o / l & s / c settings , conforming to is / iec 60947 p 2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push ( test ) to trip, trip time less then 10 ms under s / c condition, breaking capacity ics = 100% icu. u imp =8 kv, rated insulation voltage690 v.provision for uvr , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.oem shall have submitnabl / cpri / erda accrediated lab type test certificate before execution all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 77 4 pole mccb with thermal magnetic release 78 125 amp , 25 ka, adjustable o / l & adjustable s / c setting, 79 up to 100 amp , 25 ka, adjustable o / l & adjustable s / c setting, 80 providing & fixing of iso certified company made on load change over switch, front handle operated, four pole 415 v as per pwd specificationfor electrical works conforming to is / lec 60947 3 : 1999 including connections , testing etc. as required .in the following rating.appropriate type test certificate / oem test report shall be submitted .all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 81 open execution type 82 160 a 83 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed arrmouredaluminiumcable confirming to is:1554 p i / is :7098 p i of 1.1 kv withh4 grade electrolyticaluminium conductor confirming to is 8130 of purity >99.6 %, round / flat strip armouring of cables, inner / outer sheath confirming to is:5831in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench / cable tray ( with cable tie ) includingtesting etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810.for additional technical parameters of product / work refer annexure a attached with this bsr 84 10.0 sq. mm 85 2 core 86 35.0 sq. mm 87 3.5 core 88 supplying and making one end termination with nickel plated heavy duty brass single compression gland ( as per is 12943 1990 ) ) sibg type consisting of check nut, gland body, metal washer ( 3 nos. ) , outer seal rubber ring, compression nut, heavy duty aluminium lugs ( as per is 8309 1993 ) duly crimped with crimping tool, pvc tape as peris 8337 1976offollowing size ofpvc insulated & pvc sheathed / xlpe aluminium conductor cable of 1100 volt grade as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 89 3.5 x 35.0 sq.mm 90 supplying and makingend termination with heavy aluminiumlugs ( pin / ring type ) confirming to is 8309 1993 & is 8337 1976 duly crimped with crimping tool, pvc tape etc of following size.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 91 35.0 sq.mm 92 supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % copperthickness ( 250 microns ) andconfirming toul 467, is / iec 62561 2of following size and length and as per point mentioned ( a ) , ( b ) , [ c ) , ( d ) , ( e ) below : 93 ( a ) bore a hole of dia. 100 mm of required length, place the rod in the centre of hole 94 ( b ) filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, cpri / erdatested with rms capacity of minimum 30 ka for withstanding 1 second .to ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. the compound shall be tested form nabl acredeated labfor lowresistivity ( less than 0.12 ohm meter ) & high conductivity in nature with carbon as a major contentas per referance of is 3043 1987, ieee 80 2013 ( clause 14.5d ) , ieee 837 & ier 1956 with latest amendemnts 95 © connect the rod with copper strip / conductor / wire with suitable clamp made from tinned copper and ss 304 bolt 96 ( d ) place heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height250 to 300 mm. 97 ( d ) testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 98 ( e ) test certificatesfor confirming above standards from oem is mandatory. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 99 17.2 mm thick and 3 mtr. long 100 supply & laying following size earth wire in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection with gi / cu purity purity >95%thimble etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 101 8 swg copper wire 102 8 swg g.i. ( hot dipped ) wire 103 making of hole in wall ( brick / stone ) of required and placing np 2 rcc pipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 104 up to 457 mm size 105 providing & fixing ofbeestar rated copper wounded double ball bearing capacitor start, aluminium body & metallicblade ceilingfanconforming to all the performance requirements laid down in is 374:2019 including all amendments, as applicable ; & carry bis licensing ( i.e. isi marking ) with down rod up to 80 cm with secondary support safety cable ( steel rope ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 106 1200 mm sweep bee 2 star rated ( service value >=4.5 to < 5 ) 107 1200 mm sweep bee 3 star rated ( service value >=5.0 to< 5.5 ) 108 p & f 1.2mm thickm.s. recessed fan box, hexagonal / round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mmlength extended on each side . all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr 109 p & f 1.2mm thickm.s. recessed fan box, hexagonal / round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mmlength extended on each side . all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr 110 providing & fixing ofof double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor , making connections, testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 111 225 mm sweep 112 providing & fixing of heavy duty capacitor start, copper wounddouble ball bearing900 / 1400 rpm single phaseexhaustfan conforming to is:2312 isi marked in existing opening including making connections testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 113 300 mm sweep ( 900 / 1400 rpm ) 114 providing & fixing of wall mounting / pedestal type heavy duty air circulator , double ball bearing and with metal sturdy mesh guard; aluminium alloy one piece blade and conforming to is:2997, including fixing with anchor bolts, making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 115 450 mm sweep wall mounting and three speed regulator with minimum air delivery 150 cum. / minute 116 p & f of gravity louver shutter of superior quality made out of frame of18 swg m.s. sheet & louvers made from 24 swg ms sheetwith enamel paint including cost of nuts, bolts, etc as reqd.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 117 up to 380 mm size 118 providing & fixing of vertical ( bee 5 star rated ) / horizontal ( bee 3 star rated ) storage water heater with outer casing made of engineering plastic sheet ( upto 25 ltr ) / metal rust proof body ( 35 & 50 ltr ) , glass line / titanium enamel coated pressure pump compatible 8 bar pressure inner tank, glass line coated , mineral filled heating element, stem type, snap actionadjustable thermostat , dual indicating lampsinjected puf insulation, multi function valve etc. as required held in position with 2 / 4 no. 10 / 12 mm anchor fastener, duly wired with 3 core 2.5 / 4.0 sqmm pvc insulated & sheathed copper conductor and 16 a / 25a three pin plug top with portable residual current device ( prcd ) , including making inlet, outlet flexible alloyconnection, testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 119 15 ltr. 120 sitc ofmnre approved & confirming to is:12933 p 1, 2, 3 & 5 flat plate collector type solar hot water system havingcollector withzincalum sheet outer body , glass line / titanium enamel coated inner tank with metal rust proof puf insulated body includingelectrical back up, thermostat, powder coated / hot dipped galvanized ms standfor collector & tank etc. as required. of following capacity complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 121 200 litre / day 122 providing & fixing of energy efficient direct fit ( retrofit ) polycarbonate / glasshousingsmd mid power led tube rod ( with integral driver & alumn. heat sink ) , on existing fixture.system lumen efficacy = 100 lm / watt output, internal surge protection of 2.5 kv , thd < 20% , p.f.=0.95, cri >80 , life time of minimum35000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 123 1200mm , min. lumens output 2000 lmled tube rod with polycarbonate housing 124 providing & fixing of ip 20 led recessed / surface mounted, round / sqauresmd mid power led downlight with power coated die cast aluminum housingwith uv stabilized non yellowish diffuser withbis complience 2.5 kv surge protected isolated driver, with short & open circuit protection, having efficiency > 85% . system lumen efficacy of = 110 lm / watt, thd < 10 % , pf.=0.95, cri >80, life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. 125 oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 126 surface mounting ( with extruded alumn. housing ) 127 minimum lumen output 1950 lm 128 providing & fixing of ip20, 2x2 led surface / recessedmounting mid power smd type led light fixture not less than 50mm housing depth made from crca sheet steel housing, high purity / transmisivity uv stabilized non yellowish diffuser for uniform light distribution. high efficiency with 4 kv internal / external surge protection bis certified isolated driver having efficiency > 85% , with short & open circuit protection ( integral with light fixture ) . system lumen efficacy of = 120 lm / watt , thd < 10 % , p.f.=0.95, cri >80 , life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. 129 oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 130 recessed mounting 131 minimum lumen output 4200 lm 132 providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket / pole. fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with uv stabilized pc ( uv stablization report submitted for uv cover ) / toughened glass coverand secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm / wt and potted driver& has a unique bis r number withinput voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driverefficiency >85%, thd ( i ) <10%humidity 10% to 90% rh working temp 5c to 45c .driver current <750ma. the luminaireshall be bis certified and trade mark certified. life expectancyequal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min = 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs.manufactures word mark / name engraved / embossing on die cast housing to allow traceability / authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities forled fixtures. ( lm79 / lm80 ) certificate / report with liable warranty of product / accessories from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 133 led street light fixture with minimum lumen output 2450 lm 134 providing & fixing of street light bracket made out from following size of b class , medium class g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with heavy duty pole clamp, saddles suitable fastners etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 135 25 mm dia. 136 supply, drawing and testing of 4 pair, 23 awg solid bare copper wire insulated with pvc, utp ( unshielded twisted pair ) , category 6, class e, 100 ohm impedance, indoor cable as per latest ammendments of ansi / tia / eia 568 , the copper conductors should be balanced twisted in pairs, seperated by a cross member fluted pair divider & protected bypvc jacket. certified performance in a 4 connector configuration upto 100 mtrs channel requirements & transmission frequencies up to 250 mhz. in existing ms / pvc conduits / casing capping including making connections to information outlets and patch panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 137 supply and installation of unsheilded / 360 degree sheilded information outlets made of high impact plastic body with abs, fr grade halogen free material with provision for protection against dust in jack, suitable for cat 6 / 6a application complying to latest ammendments, according. to cat. 6 / 6a channel, it should support channel as well as components requirements of cat.6 / 6a standards at frequencies of up to 250 to 500 mhz. cat 6 / 6a unshielded / shielded jack should be suitable to terminate 4 pair, 23 / 24 awg solid / stranded wire diameters, using 100 ohm unshielded / shielded balance twisted pair cable, the jack should have tooless / impact termination on reliable copper tin plated insulation displacement contact, with easy lock mechanism, it supports iec 60603 7 4 and complied with ansi / tia / eia 568 c.2 standard. jack should be rj11, rj12 & rj45 compatible. should support ethernet 1.2 gb / s atm, digital video and broadband / baseband analog video, voice over internet protocal ( voip ) specifications in existing modular / ms boxes along with necessory connections as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 138 cat 6, un sheilded information outlet 139 supply & fixing of square faceplate for flush / surface mount information outlets single / dual or quad aperture , material should bepc+abs body, suitable for rj45 unshielded / shielded connection modules. should match with i. o. oem. dimensions should be 86mm x 86mm as required complete in all respect.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 140 single aperture 141 supply , installation and testing of 4 pair, 100 ohm impedance, cat 6 / 6a / class e / ea patch cords should be constructed of minimum 23 / 24 awg, stranded bare copper cable with frpvc / lszh jacket, with an enhanced performance by factory moulded rj45 connectors with strain relief boots as per ansi / tia / eia 568 c.2 suitable for cat 6 / 6a application complying to latest ammendments category 6 / 6a standards, according. to tia568c.2, iso / iec 11801, en 50173, iec 60603 7 51, en 60603 7, ieee 802.3an minimum requirement for 1g base t to 10g base t performance. patch cords shall be straight thru cable compatible with both t568 a and t568 b wiring schemes, should support ieee 802.3af / ieee 802.3at for poe applications, minimum 750 to 1000 mating cycles in plug contacts for long durability, should support ethernet 10gbase t, 1.2 gb / s atm, token ring 4 / 16, digital video and broadband / baseband analog video, voice over internet protocal ( voip ) .all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 142 cat 6, u / utp ( unscreened / un sheilded twisted pair ) patch cord 143 1 mtr 144 supply, installation, & testing of 19 1u rack mounted / surface mounted aluminum / crca 1.2mm powder coated, multimode glass fiber optic cable patch panel / liu loaded with flangless / screwable adapters for st / e 2000 / sc / lc / mt rj / pc type, it should have easy removable top plate with push buttons, there should be a splice tray installed in the patch panel / liu which can handle the fiber cores, splice tray should be pc+abs material, it should include accessories like mounting hardware, gormetts, heat shrink tubes / sleevs, screws, nuts to install the panel for rack / wallmount applications as per requirement complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 145 multi mode liu 12 ports 146 supply & installation of ip 20 & ik 08 , ul listedwall mounted double section communication enclosure ( rack ) made from powder coated ( 60 to 80 micron ) crca sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door, vertical mounting rail 1.6 mm with umarking , with all round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. accessories like: 1 no of 19 1u horizontal cable manager, 1 no of 90 cfm 230v ac fan with 1 mts long cable, mounting hardware , 1 no of 19 1u, mountable socket strips with 5 nos of 5a universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with suitable anchor fastneretc as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 147 6 u rack with width 600 mm &depth 400 mm + 100 mm 148 supply , installation, testing and comissioning ofmanaged layer 2 intelligent 10 / 100 ethernet switch providing 24 x 10 / 100 / 1000 mbps giga ethernet ports / with min 2 sfp giga ports ( provision for fiber giga connectivity ) with related lan base software including making connections etc as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 149 sitc of single stage, water cooled, high speed ( 2880 rpm ) , horizontal, centrifugal, openwell submersible pumps set pre filled with coolent water and fitted with mechanical seal t / c vs t / c, thrust bearing shall be ofcarbon + s.s.the stator body of single phase pumpshall be of ss and rest of all shall be of cast iron. all casting parts should be cathod electro deposition ( ced ) coated and other construction material should be confirming to is : 14220: 2018 . the overall performance of pump shall confirm to bee energy efficiency level of 3 star. valid bee certificate from oem must be submitted for the same. motor should be ie2 class as per iec 60034 2 1: 2007, iec 60034 30: 2008, & is12615:2011, including making connection etc as required complete in all respect. oem shall have submitnabl / cpri / erda accrediatedlab type test certificate before execution. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 150 1.0 hp, 1 ø, ( 7 12 ) mtr, ( 405 240 ) lpm 151 sitc of monoblock motor pump set isi marked ( is:9079 2002 ) with tefc motor, motor should be ie2 class as per iec 60034 2 1: 2007, iec 60034 30: 2008, & is12615:2011. with stainless steel impellor, stainless steel shaft, mechanical seal, single / three phase ( 240 440 v ) permanent split capacitor type ( psc ) , fitted with thermal overload protection, including cost of hardware etc on existing platform complete. pump shall have following hp rating, phase, head, minimum discharge respectively complete in all respect. oem shall have submitnabl / cpri / erda accrediatedlab type test certificate before execution. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 152 1.0 hp, 1 ø, ( 10 120 ) mtr, ( 30 12 ) lpm 153 supply , installation, testing and comissioning ofinverter type air cooled hi wall split type air conditioners with latest star rating system as per bee amended upto date complete with indoor unit ( idu ) , out door unit ( odu ) , surface / concealed copper refrigerant piping with insulation ( closed cell elastomeric nitrile rubber tubular pipe section ) upto 3 mtr ( idu to odu ) , copper power cable upto 3.5 mtr ( idu to odu ) , r 32 / r 410 green refrigerant, wireless remote control, suitable for working between 230v + / 10% with low & high voltage cutoff and50 hz , single phaseacsupply capable of performing cooling, dehumidification, air circulation of following capacity with scroll / rotary compressor. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 154 1.5 tr iseer not less then 3.8 155 providing & fixing of is : 4985 2000 class 4 ( 10 kgf / sqcm ) upvc drain water piping withfittings ( is:7834 & 10kgf / sqcm ) like elbow, socket, tee, solvent cement jointing, support with ms hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following nominal sizes. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 156 25 mm 157 supply, fixing and testing of following capacity iso certified company made wall mounted stabilizer having output voltage variation from 200 v to 250 v ( + / 5% ) with input voltage variation from 170 v to 260 v, time delay facility from 2 to 4 minute and high cutoff at 270 v with providing of 16 amp / 20 amp industrialplug top making connection etc complete in all respect.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 158 4 kva 159 making hole in stone masonary / rcc wall / rcc slab with core cutter for accomodating refrigerant pipe / drain pipe / ms pipe / cables etc of following dia 160 150 mm dia per running inch length 161 supply & fixing ms powder coated stand suitable for 1.0 / 1.5 / 2.0 tr outdoor type of split ac.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 162 supply & fixing of dry powder agent ( as per is 4308:2019 ) , abc typefire extinguisher ( stored pressure type ) conforming to is:15683:2018 , powder coated internal & external surface deep drawn cylinder body of mild steel cr2 grade conforming to is: 513, squeeze grip forged brass release valve with inbuilt safety release device, diaphragm type, 0 to 28 bar range pressure gauge, 450 mm long epdm discharge tube, qr code for product traceability including fixing on wall with suitable anchor fasteners as required of following capacity. test certificates of all the parameters along with hydro test & burst test ( for cylinder body ) certificatefrom oem / external nabl accrediated lab is to be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 163 4 kg...

Medical Health And Family Welfare - Rajasthan

36432910 tender for electrical work in the construction of phc building at basai jogiyan ( thangagazi ) distt. alwar wiring of light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked mms ( is:9537 p iii ) virgin material pvc conduit & itsisi marked ( is:3419 1988 ) accessories, round tiles, 1.2 mm thickhot dipped galvanized modular box with earth terminal, 10a modular switch, modular face plate with grid plate, 3 pin ceiling rose / holder / 3 way connector, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 3 short point ( up to 3 mtr. ) 4 medium point ( up to 6 mtr. ) 5 long point ( up to 10 mtr. ) 6 wiring of twin control light point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) in recessed isi markedmms ( is:9537 p iii ) pvc conduit & its isi marked ( is:3419 1988 ) accessories, round tiles, 2 nos hot dipped galvanized m.s modularbox of 1.2 mm thickwith earth terminal, 2 nos10 a two way modular switch, 3 pin ceiling rose / holder / 3 way connector , modular face plate with grid plate, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 7 medium point ( up to 6 mtr. ) 8 long point ( up to 10 mtr. ) 9 wiring of 3 / 5 pin 6 amp. light plug point with 1.5 sq. mm nominal sizefr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked mms ( is:9537 p iii ) pvc conduit & its isi marked ( is:3419 1988 ) accessories, hot dipped galvanizedmodular box of 1.2 mm thick with earth terminal, 10 a modularswitch, 3 / 5 pin 6 a modular socket, modular face plate with grid plate, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 10 on board 11 s&f following sizes ( dia. ) of isi marked virgin material mms ( is:9537 p iii ) pvc conduit along withisi marked ( is:3419 1988 ) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. for additional technical parameters of product / work refer annexure a attached with this bsr 12 20 mm 13 25 mm 14 32 mm 15 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from99.90 % purity copper, class 5 stranding in acc. to is:8130 / iec 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation pvc type a / c / d , flame retardant as per is 10810 53, better amperage rating as per is:3961 part 5, in existingsurface or recessed pvc / ms conduit / casing capping making connections with copper lugs of suitable size, ferrules, testing etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of product / work refer annexure a attached with this bsr 16 1 x 1.5 sq.mm 17 3x 1.5 sq.mm 18 2 x 2.5 sq. mm. + 1x1.5sqmm 19 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 20 4 x 10.0 sq.mm 21 4 x 6.0 sq.mm 22 1 x 4.0 sq.mm 23 1 x 2.5 sq.mm 24 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. 25 supplying and drawing pe insulated & pvc sheathed unarmoured telephone cable with 0.5 mm dia. solid annealed electrolytic grade bare copper conductor as per is: 8130 / 84 &confirming to tec specification gr / wir / 06 03 march 2002in existingsurface or recessed conduit / casing capping. including ferruling on each pair for identification etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 26 2 pair 27 p & f in position frame made out of m.s. angle ( riveted or welded ) finished with two coats of red oxide and two coats enamel paint including cutting, welding, holes etc.of following sizes as required.for additional technical parameters of product / work refer annexure a attached with this bsr 28 40mm x 40mm x 5mm 29 p & f paper phenolic resin bondedlaminates confirming to is : 2036 1995 for boxes / frames including making holes for switches etc, with brass screws, washers / zinc platednut and bolts as required. for additional technical parameters of product / work refer annexure a attached with this bsr 30 6.4 mm thick 31 p & f phenolic laminated sheet 2.0 mm thick of following size . including screws, cup washer as required.for additional technical parameters of product / work refer annexure a attached with this bsr 32 75 mm dia 33 providing & fixing of 240 / 415 v ac mcb with positive isolation of 10 ka breaking capacity ( b / c / d tripping characteristic as per type of load andsite requirement ) 4 kv impulse withstand voltage, isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted inexisting distribution board / sheets, minimum electrical operation 20, 000 upto 20 a rating and 10, 000 upto 63 a, 5000 for 80 a & above ratingincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 34 single pole mcb ( with b / c curve tripping characteristics ) 35 6 a to 32 a rating 36 double pole mcb ( with b / c curve tripping characteristics ) 37 6 a to 32 a rating 38 four pole mcb ( with b / c curve tripping characteristics ) 39 6 a to 32 a rating 40 50 / 63 a rating 41 providing & fixing of recessed / surface mounting heavy duty horizontal type double door ( metal / glazed ) distribution board with metal end box made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3, powder painted complete with reversible door ( for double door db only ) 100 amp. insulated copper bus bar / shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar, masking sheet, making internal db terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 42 metal door ( single phase ) ik 09 and ip 43 with metal end box 43 16 way ( 16+2 ) 44 metal door ( three phase ) ik 09 and ip 43with metal end box 45 6 way 46 p&f metal clad / plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain / bakelite base in recessed / surface mounting heavy duty enclosure made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3. powder painted ( without mcb ) including making connections, testing etc.as required.for additional technical parameters of product / work refer annexure a attached with this bsr 47 20 amp, 3 pin + scrapping earth, 4 module 48 p & f of industrial plug and socket conforming to iec 60309 1 / 2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. for additional technical parameters of product / work refer annexure a attached with this bsr 49 ip 67 panel mounted socket 50 32 a 3 pin ( 2p+e ) 51 providing & fixing of flush typenon modular single line telephone jackmade out fromindustrial grade polycarbonate or fire resistant abs material, including making connection testing etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 52 providing & fixing of ding dong / musical chime bell as per pwd specification for electrical works, including making connection testing etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 53 providing & fixing of modular type 120 w step fan regulator duly isi marked ( is 11037:1984 ) with cm / l no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , includingall as per pre approved by engineer in charge, making connections, testing etc. as required.for additional technical parameters of product / work refer annexure a attached with this bsr 54 5 step fan regulator 2 module 360 dgree rotating 55 supplying and fixing of power plug point with modular accessories as per pwd specification for electrical works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal / connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofisi marked modular 16 amp. switch ( is :3854 ) and 6 / 16 amp. socket outlet ( is:1293 ) making connection , testing , etc. as required. for specification ofwiring accessories refer chaptere 07related item & for additional technical parameters of product / work refer annexure a attached with this bsr 56 p & f krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted, including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 57 10 pairs 58 sitc of ip 42 and general construction confirming to is:8623 : 1993, wall / free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andother parameters requiredas per point ( a ) , ( b ) , ( c ) , ( d ) , ( e ) , ( f ) , ( g ) , ( h ) as below: 59 ( a ) thickness of crca sheet shallbe 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 60 ( b ) complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel.the panel having pe foam / neoprene rubber gasket of not less than 3mm thickness , required hardware , concealed hinged door with key type locking arrangement for equipment / switchgear earthed with 2.5 sq.mm braided copper wire. 61 [ c ) interconnection between bus bar and switchgears / cable shall be rigidly supported and made out by flexible copper wires ( up to 63 amp ) and by solid bus bar ( >63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only.all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgearis to be paid extra ) 62 ( d ) wiring between components within switchgear and incoming / outgoing cableshall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 63 ( e ) all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be ‘point to point’ ( no wire splitting or tee connections ) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 64 ( f ) floor mounted panel shall be mounted on base frame of ismcchannel size 100 x 50 x 5 mm ( to be paid extra ) 65 ( g ) tests: the insulation resistance ( with 1000 v megger ) and high voltage power frequency test ( by applying a voltage of 2.5kv for one minute ) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. the insulation resistance shall not be less than three megaohm. ct secondary current injection test shall also be carried out. 66 ( h ) only outer surface area on all sides shall be measured & panel to be fabricated only from cpri approved fabricator only ( cpri test certificates to be submitted ) all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 67 supplying and fixing of aluminium ( iec 60105 iso 209 1, 2 ) / copper ( iec 60028 ) bus bar by means of smc / dmc type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 68 electrolytic grade aluminium bus bar 6010 grade 69 providing & fixing of bis approvedcurrent transformeras per pwd specification for electrical works , isi marked as peris 2705 1992 / conforming to iec 60044 1, with secondary terminalof ct shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredcurrent transformer ring type tape wound / resin cast wound as per is 16227 with, accuracy cl, ct ratio and burden as specified. isf<=5, cu cross section of secondary wire 1.5sqmm ( minimum ) , including all necessary support in existing panel including connection etc. as required . all as per pre approved by engineer in charge.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 70 ring type tape wound ct 71 c t class 1, ratio 200 / 5 to 300 / 5, burden 10 va 72 providing & fixing of110 / 220 v, unibody led indicatinglamp iec 60947with integral circuit, ip 65 above panel &ip 20 terminal block, approx. body dia for panel not less then 20 mm, length min. 50mm, front led cover dia min.29 mm, contact material phospher bronze for led, pcb contacts shall be ofbrass ( tin plated ) , impulsedielectric tested for 2.5 kv, rated insulation resistance shall be 100 m ohm at 500vdcincluding connection etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 73 red / yellow / green colour 74 providing & fixing of electricalinsulating rubber matts as per pwd specification for electrical works, isi marked confirming to is: 15652 / 2006with one sideanti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 75 3.3 kv, class a 2 mm thick with proof voltage 10 kv ac ( rms ) and break down voltage 30 kv ac ( rms ) 76 sitc of3 / 4pole current limiting moulded case circuit breaker ( mccb ) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440 / 415 v, 50 hz; o / l & s / c settings , conforming to is / iec 60947 p 2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push ( test ) to trip, trip time less then 10 ms under s / c condition, breaking capacity ics = 100% icu. u imp =8 kv, rated insulation voltage690 v.provision for uvr , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.oem shall have submitnabl / cpri / erda accrediated lab type test certificate before execution all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 77 4 pole mccb with thermal magnetic release 78 125 amp , 25 ka, adjustable o / l & adjustable s / c setting, 79 up to 100 amp , 25 ka, adjustable o / l & adjustable s / c setting, 80 providing & fixing of iso certified company made on load change over switch, front handle operated, four pole 415 v as per pwd specificationfor electrical works conforming to is / lec 60947 3 : 1999 including connections , testing etc. as required .in the following rating.appropriate type test certificate / oem test report shall be submitted .all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 81 open execution type 82 160 a 83 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed arrmouredaluminiumcable confirming to is:1554 p i / is :7098 p i of 1.1 kv withh4 grade electrolyticaluminium conductor confirming to is 8130 of purity >99.6 %, round / flat strip armouring of cables, inner / outer sheath confirming to is:5831in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench / cable tray ( with cable tie ) includingtesting etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810.for additional technical parameters of product / work refer annexure a attached with this bsr 84 10.0 sq. mm 85 2 core 86 35.0 sq. mm 87 3.5 core 88 supplying and making one end termination with nickel plated heavy duty brass single compression gland ( as per is 12943 1990 ) ) sibg type consisting of check nut, gland body, metal washer ( 3 nos. ) , outer seal rubber ring, compression nut, heavy duty aluminium lugs ( as per is 8309 1993 ) duly crimped with crimping tool, pvc tape as peris 8337 1976offollowing size ofpvc insulated & pvc sheathed / xlpe aluminium conductor cable of 1100 volt grade as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 89 3.5 x 35.0 sq.mm 90 supplying and makingend termination with heavy aluminiumlugs ( pin / ring type ) confirming to is 8309 1993 & is 8337 1976 duly crimped with crimping tool, pvc tape etc of following size.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 91 35.0 sq.mm 92 supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % copperthickness ( 250 microns ) andconfirming toul 467, is / iec 62561 2of following size and length and as per point mentioned ( a ) , ( b ) , [ c ) , ( d ) , ( e ) below : 93 ( a ) bore a hole of dia. 100 mm of required length, place the rod in the centre of hole 94 ( b ) filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, cpri / erdatested with rms capacity of minimum 30 ka for withstanding 1 second .to ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. the compound shall be tested form nabl acredeated labfor lowresistivity ( less than 0.12 ohm meter ) & high conductivity in nature with carbon as a major contentas per referance of is 3043 1987, ieee 80 2013 ( clause 14.5d ) , ieee 837 & ier 1956 with latest amendemnts 95 © connect the rod with copper strip / conductor / wire with suitable clamp made from tinned copper and ss 304 bolt 96 ( d ) place heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height250 to 300 mm. 97 ( d ) testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 98 ( e ) test certificatesfor confirming above standards from oem is mandatory. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 99 17.2 mm thick and 3 mtr. long 100 supply & laying following size earth wire in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection with gi / cu purity purity >95%thimble etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 101 8 swg copper wire 102 8 swg g.i. ( hot dipped ) wire 103 making of hole in wall ( brick / stone ) of required and placing np 2 rcc pipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 104 up to 457 mm size 105 providing & fixing ofbeestar rated copper wounded double ball bearing capacitor start, aluminium body & metallicblade ceilingfanconforming to all the performance requirements laid down in is 374:2019 including all amendments, as applicable ; & carry bis licensing ( i.e. isi marking ) with down rod up to 80 cm with secondary support safety cable ( steel rope ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 106 1200 mm sweep bee 2 star rated ( service value >=4.5 to < 5 ) 107 1200 mm sweep bee 3 star rated ( service value >=5.0 to< 5.5 ) 108 p & f 1.2mm thickm.s. recessed fan box, hexagonal / round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mmlength extended on each side . all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr 109 p & f 1.2mm thickm.s. recessed fan box, hexagonal / round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mmlength extended on each side . all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr 110 providing & fixing ofof double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor , making connections, testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 111 225 mm sweep 112 providing & fixing of heavy duty capacitor start, copper wounddouble ball bearing900 / 1400 rpm single phaseexhaustfan conforming to is:2312 isi marked in existing opening including making connections testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 113 300 mm sweep ( 900 / 1400 rpm ) 114 providing & fixing of wall mounting / pedestal type heavy duty air circulator , double ball bearing and with metal sturdy mesh guard; aluminium alloy one piece blade and conforming to is:2997, including fixing with anchor bolts, making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 115 450 mm sweep wall mounting and three speed regulator with minimum air delivery 150 cum. / minute 116 p & f of gravity louver shutter of superior quality made out of frame of18 swg m.s. sheet & louvers made from 24 swg ms sheetwith enamel paint including cost of nuts, bolts, etc as reqd.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 117 up to 380 mm size 118 providing & fixing of vertical ( bee 5 star rated ) / horizontal ( bee 3 star rated ) storage water heater with outer casing made of engineering plastic sheet ( upto 25 ltr ) / metal rust proof body ( 35 & 50 ltr ) , glass line / titanium enamel coated pressure pump compatible 8 bar pressure inner tank, glass line coated , mineral filled heating element, stem type, snap actionadjustable thermostat , dual indicating lampsinjected puf insulation, multi function valve etc. as required held in position with 2 / 4 no. 10 / 12 mm anchor fastener, duly wired with 3 core 2.5 / 4.0 sqmm pvc insulated & sheathed copper conductor and 16 a / 25a three pin plug top with portable residual current device ( prcd ) , including making inlet, outlet flexible alloyconnection, testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 119 15 ltr. 120 sitc ofmnre approved & confirming to is:12933 p 1, 2, 3 & 5 flat plate collector type solar hot water system havingcollector withzincalum sheet outer body , glass line / titanium enamel coated inner tank with metal rust proof puf insulated body includingelectrical back up, thermostat, powder coated / hot dipped galvanized ms standfor collector & tank etc. as required. of following capacity complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 121 200 litre / day 122 providing & fixing of energy efficient direct fit ( retrofit ) polycarbonate / glasshousingsmd mid power led tube rod ( with integral driver & alumn. heat sink ) , on existing fixture.system lumen efficacy = 100 lm / watt output, internal surge protection of 2.5 kv , thd < 20% , p.f.=0.95, cri >80 , life time of minimum35000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 123 1200mm , min. lumens output 2000 lmled tube rod with polycarbonate housing 124 providing & fixing of ip 20 led recessed / surface mounted, round / sqauresmd mid power led downlight with power coated die cast aluminum housingwith uv stabilized non yellowish diffuser withbis complience 2.5 kv surge protected isolated driver, with short & open circuit protection, having efficiency > 85% . system lumen efficacy of = 110 lm / watt, thd < 10 % , pf.=0.95, cri >80, life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. 125 oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 126 surface mounting ( with extruded alumn. housing ) 127 minimum lumen output 1950 lm 128 providing & fixing of ip20, 2x2 led surface / recessedmounting mid power smd type led light fixture not less than 50mm housing depth made from crca sheet steel housing, high purity / transmisivity uv stabilized non yellowish diffuser for uniform light distribution. high efficiency with 4 kv internal / external surge protection bis certified isolated driver having efficiency > 85% , with short & open circuit protection ( integral with light fixture ) . system lumen efficacy of = 120 lm / watt , thd < 10 % , p.f.=0.95, cri >80 , life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. 129 oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 130 recessed mounting 131 minimum lumen output 4200 lm 132 providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket / pole. fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with uv stabilized pc ( uv stablization report submitted for uv cover ) / toughened glass coverand secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm / wt and potted driver& has a unique bis r number withinput voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driverefficiency >85%, thd ( i ) <10%humidity 10% to 90% rh working temp 5c to 45c .driver current <750ma. the luminaireshall be bis certified and trade mark certified. life expectancyequal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min = 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs.manufactures word mark / name engraved / embossing on die cast housing to allow traceability / authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities forled fixtures. ( lm79 / lm80 ) certificate / report with liable warranty of product / accessories from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 133 led street light fixture with minimum lumen output 2450 lm 134 providing & fixing of street light bracket made out from following size of b class , medium class g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with heavy duty pole clamp, saddles suitable fastners etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 135 25 mm dia. 136 supply, drawing and testing of 4 pair, 23 awg solid bare copper wire insulated with pvc, utp ( unshielded twisted pair ) , category 6, class e, 100 ohm impedance, indoor cable as per latest ammendments of ansi / tia / eia 568 , the copper conductors should be balanced twisted in pairs, seperated by a cross member fluted pair divider & protected bypvc jacket. certified performance in a 4 connector configuration upto 100 mtrs channel requirements & transmission frequencies up to 250 mhz. in existing ms / pvc conduits / casing capping including making connections to information outlets and patch panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 137 supply and installation of unsheilded / 360 degree sheilded information outlets made of high impact plastic body with abs, fr grade halogen free material with provision for protection against dust in jack, suitable for cat 6 / 6a application complying to latest ammendments, according. to cat. 6 / 6a channel, it should support channel as well as components requirements of cat.6 / 6a standards at frequencies of up to 250 to 500 mhz. cat 6 / 6a unshielded / shielded jack should be suitable to terminate 4 pair, 23 / 24 awg solid / stranded wire diameters, using 100 ohm unshielded / shielded balance twisted pair cable, the jack should have tooless / impact termination on reliable copper tin plated insulation displacement contact, with easy lock mechanism, it supports iec 60603 7 4 and complied with ansi / tia / eia 568 c.2 standard. jack should be rj11, rj12 & rj45 compatible. should support ethernet 1.2 gb / s atm, digital video and broadband / baseband analog video, voice over internet protocal ( voip ) specifications in existing modular / ms boxes along with necessory connections as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 138 cat 6, un sheilded information outlet 139 supply & fixing of square faceplate for flush / surface mount information outlets single / dual or quad aperture , material should bepc+abs body, suitable for rj45 unshielded / shielded connection modules. should match with i. o. oem. dimensions should be 86mm x 86mm as required complete in all respect.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 140 single aperture 141 supply , installation and testing of 4 pair, 100 ohm impedance, cat 6 / 6a / class e / ea patch cords should be constructed of minimum 23 / 24 awg, stranded bare copper cable with frpvc / lszh jacket, with an enhanced performance by factory moulded rj45 connectors with strain relief boots as per ansi / tia / eia 568 c.2 suitable for cat 6 / 6a application complying to latest ammendments category 6 / 6a standards, according. to tia568c.2, iso / iec 11801, en 50173, iec 60603 7 51, en 60603 7, ieee 802.3an minimum requirement for 1g base t to 10g base t performance. patch cords shall be straight thru cable compatible with both t568 a and t568 b wiring schemes, should support ieee 802.3af / ieee 802.3at for poe applications, minimum 750 to 1000 mating cycles in plug contacts for long durability, should support ethernet 10gbase t, 1.2 gb / s atm, token ring 4 / 16, digital video and broadband / baseband analog video, voice over internet protocal ( voip ) .all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 142 cat 6, u / utp ( unscreened / un sheilded twisted pair ) patch cord 143 1 mtr 144 supply, installation, & testing of 19 1u rack mounted / surface mounted aluminum / crca 1.2mm powder coated, multimode glass fiber optic cable patch panel / liu loaded with flangless / screwable adapters for st / e 2000 / sc / lc / mt rj / pc type, it should have easy removable top plate with push buttons, there should be a splice tray installed in the patch panel / liu which can handle the fiber cores, splice tray should be pc+abs material, it should include accessories like mounting hardware, gormetts, heat shrink tubes / sleevs, screws, nuts to install the panel for rack / wallmount applications as per requirement complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 145 multi mode liu 12 ports 146 supply & installation of ip 20 & ik 08 , ul listedwall mounted double section communication enclosure ( rack ) made from powder coated ( 60 to 80 micron ) crca sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door, vertical mounting rail 1.6 mm with umarking , with all round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. accessories like: 1 no of 19 1u horizontal cable manager, 1 no of 90 cfm 230v ac fan with 1 mts long cable, mounting hardware , 1 no of 19 1u, mountable socket strips with 5 nos of 5a universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with suitable anchor fastneretc as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 147 6 u rack with width 600 mm &depth 400 mm + 100 mm 148 supply , installation, testing and comissioning ofmanaged layer 2 intelligent 10 / 100 ethernet switch providing 24 x 10 / 100 / 1000 mbps giga ethernet ports / with min 2 sfp giga ports ( provision for fiber giga connectivity ) with related lan base software including making connections etc as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 149 sitc of single stage, water cooled, high speed ( 2880 rpm ) , horizontal, centrifugal, openwell submersible pumps set pre filled with coolent water and fitted with mechanical seal t / c vs t / c, thrust bearing shall be ofcarbon + s.s.the stator body of single phase pumpshall be of ss and rest of all shall be of cast iron. all casting parts should be cathod electro deposition ( ced ) coated and other construction material should be confirming to is : 14220: 2018 . the overall performance of pump shall confirm to bee energy efficiency level of 3 star. valid bee certificate from oem must be submitted for the same. motor should be ie2 class as per iec 60034 2 1: 2007, iec 60034 30: 2008, & is12615:2011, including making connection etc as required complete in all respect. oem shall have submitnabl / cpri / erda accrediatedlab type test certificate before execution. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 150 1.0 hp, 1 ø, ( 7 12 ) mtr, ( 405 240 ) lpm 151 sitc of monoblock motor pump set isi marked ( is:9079 2002 ) with tefc motor, motor should be ie2 class as per iec 60034 2 1: 2007, iec 60034 30: 2008, & is12615:2011. with stainless steel impellor, stainless steel shaft, mechanical seal, single / three phase ( 240 440 v ) permanent split capacitor type ( psc ) , fitted with thermal overload protection, including cost of hardware etc on existing platform complete. pump shall have following hp rating, phase, head, minimum discharge respectively complete in all respect. oem shall have submitnabl / cpri / erda accrediatedlab type test certificate before execution. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 152 1.0 hp, 1 ø, ( 10 120 ) mtr, ( 30 12 ) lpm 153 supply , installation, testing and comissioning ofinverter type air cooled hi wall split type air conditioners with latest star rating system as per bee amended upto date complete with indoor unit ( idu ) , out door unit ( odu ) , surface / concealed copper refrigerant piping with insulation ( closed cell elastomeric nitrile rubber tubular pipe section ) upto 3 mtr ( idu to odu ) , copper power cable upto 3.5 mtr ( idu to odu ) , r 32 / r 410 green refrigerant, wireless remote control, suitable for working between 230v + / 10% with low & high voltage cutoff and50 hz , single phaseacsupply capable of performing cooling, dehumidification, air circulation of following capacity with scroll / rotary compressor. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 154 1.5 tr iseer not less then 3.8 155 providing & fixing of is : 4985 2000 class 4 ( 10 kgf / sqcm ) upvc drain water piping withfittings ( is:7834 & 10kgf / sqcm ) like elbow, socket, tee, solvent cement jointing, support with ms hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following nominal sizes. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 156 25 mm 157 supply, fixing and testing of following capacity iso certified company made wall mounted stabilizer having output voltage variation from 200 v to 250 v ( + / 5% ) with input voltage variation from 170 v to 260 v, time delay facility from 2 to 4 minute and high cutoff at 270 v with providing of 16 amp / 20 amp industrialplug top making connection etc complete in all respect.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 158 4 kva 159 making hole in stone masonary / rcc wall / rcc slab with core cutter for accomodating refrigerant pipe / drain pipe / ms pipe / cables etc of following dia 160 150 mm dia per running inch length 161 supply & fixing ms powder coated stand suitable for 1.0 / 1.5 / 2.0 tr outdoor type of split ac.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 162 supply & fixing of dry powder agent ( as per is 4308:2019 ) , abc typefire extinguisher ( stored pressure type ) conforming to is:15683:2018 , powder coated internal & external surface deep drawn cylinder body of mild steel cr2 grade conforming to is: 513, squeeze grip forged brass release valve with inbuilt safety release device, diaphragm type, 0 to 28 bar range pressure gauge, 450 mm long epdm discharge tube, qr code for product traceability including fixing on wall with suitable anchor fasteners as required of following capacity. test certificates of all the parameters along with hydro test & burst test ( for cylinder body ) certificatefrom oem / external nabl accrediated lab is to be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr ....

Public Works Department - Rajasthan

36408724 tender for electrical work in govt. srg hospital jhalawar wiring of light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) on surface isi marked ( is:14927 p ii ) virgin materialupvc trunking & its accessories, hot dipped galvanizedmodular box of 1.2 mm thickwith earth terminal / surface moulded virgin materialupvcmodular box , 10 a modular switch, modular faceplate with grid plate, 3 pin ceiling rose / holder / 3 way connector, screws, making connections, testing etc. as required. for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 2 short point ( up to 3 mtr. ) 3 medium point ( up to 6 mtr. ) 4 long point ( up to 10 mtr. ) 5 wiring of twin control light point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) of approved make on surfaceisi marked ( is:14927 p ii ) virgin materialupvc trunking & its accessories, hot dipped galvanizedmodular box of 1.2 mm thickwith earth terminal / surface 2 no. moulded virgin materialupvcmodular box , 2 nos 10 a two way modular switch, 3 pin ceiling rose / holder / 3 way connector , modular face plate with grid plate, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 6 medium point ( up to 6 mtr. ) 7 long point ( up to 10 mtr.. ) 8 wiring of 3 / 5 pin 6 amp. light plug point with 1.5 sq. mm nominal sizefr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) on surfaceisi marked ( is:14927 p ii ) virgin materialupvc trunking & its accessories, hot dipped galvanizedmodular box of 1.2 mm thickwith earth terminal / surface moulded virgin materialupvcmodular box, modular 10a switch, 3 / 5 pin6 amodular socket, modular face plate with grid plate, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 9 on board 10 s&f following sizesof isi marked ( is:14927 p ii ) virgin materialupvc trunking along with accessorieslike coupler, inner, outer, elbow, square box, tee, end cap etc. on surfacewithscrews, expansionfastenersas required. for additional technical parameters of product / work refer annexure a attached with this bsr 11 25 mm x 12 mm 12 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from99.90 % purity copper, class 5 stranding in acc. to is:8130 / iec 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation pvc type a / c / d , flame retardant as per is 10810 53, better amperage rating as per is:3961 part 5, in existingsurface or recessed pvc / ms conduit / casing capping making connections with copper lugs of suitable size, ferrules, testing etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of product / work refer annexure a attached with this bsr 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 p & f paper phenolic resin bondedlaminates confirming to is : 2036 1995 for boxes / frames including making holes for switches etc, with brass screws, washers / zinc platednut and bolts as required. for additional technical parameters of product / work refer annexure a attached with this bsr 16 3.0 mm thick 17 providing & fixing of 240 / 415 v ac mcb with positive isolation of 10 ka breaking capacity ( b / c / d tripping characteristic as per type of load andsite requirement ) 4 kv impulse withstand voltage, isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted inexisting distribution board / sheets, minimum electrical operation 20, 000 upto 20 a rating and 10, 000 upto 63 a, 5000 for 80 a & above ratingincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 18 single pole mcb ( with b / c curve tripping characteristics ) 19 6 a to 32 a rating 20 double pole mcb ( with b / c curve tripping characteristics ) 21 40 a rating 22 four pole mcb ( with b / c curve tripping characteristics ) 23 50 / 63 a rating 24 providing & fixing of recessed / surface mounting heavy duty horizontal type double door ( metal / glazed ) distribution board with metal end box made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3, powder painted complete with reversible door ( for double door db only ) 100 amp. insulated copper bus bar / shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar, masking sheet, making internal db terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 25 metal door ( single phase ) ik 09 and ip 43 with metal end box 26 4 way ( 4+2 ) 27 p & f isi marked ( is:3854 ) 6 amp. flush type non modular switchwith cm / l no. printed and made out from industrial grade polycarbonate or fire resistant abs material including cutting hole in tile and making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 28 p & f isi marked ( is :3854 ) 16 amp. flush type non modular switch cm / l no. printed and made out from industrial grade polycarbonate or fire resistant abs material including cutting hole in tile and making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 29 providing & fixing ofof 3 / 5 pin 6 amp. flush typenon modular socketmade out from industrial grade polycarbonate or fire resistant abs material, brass terminal with porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 30 providing & fixing of3 / 6 pin 16 amp flush type non modular socketmade out from industrial grade polycarbonate or fire resistant abs material, brass terminal with porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 31 sitc of3 / 4pole current limiting moulded case circuit breaker ( mccb ) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440 / 415 v, 50 hz; o / l & s / c settings , conforming to is / iec 60947 p 2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push ( test ) to trip, trip time less then 10 ms under s / c condition, breaking capacity ics = 100% icu. u imp =8 kv, rated insulation voltage690 v.provision for uvr , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.oem shall have submitnabl / cpri / erda accrediated lab type test certificate before execution all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 32 4 pole mccb with thermal magnetic release 33 160 amp , 25 ka, adjustable o / l & adjustable s / c setting, 34 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed arrmouredaluminiumcable confirming to is:1554 p i / is :7098 p i of 1.1 kv withh4 grade electrolyticaluminium conductor confirming to is 8130 of purity >99.6 %, round / flat strip armouring of cables, inner / outer sheath confirming to is:5831in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench / cable tray ( with cable tie ) includingtesting etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810.for additional technical parameters of product / work refer annexure a attached with this bsr 35 10.0 sq. mm 36 2 core 37 making of hole in wall ( brick / stone ) of required and placing np 2 rcc pipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 38 up to 457 mm size 39 providing & fixing of heavy duty capacitor start, copper wounddouble ball bearing900 / 1400 rpm single phaseexhaustfan conforming to is:2312 isi marked in existing opening including making connections testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 40 300 mm sweep ( 900 / 1400 rpm ) 41 380 mm sweep ( 900 / 1400 rpm ) 42 p & f of gravity louver shutter of superior quality made out of frame of18 swg m.s. sheet & louvers made from 24 swg ms sheetwith enamel paint including cost of nuts, bolts, etc as reqd.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 43 up to 380 mm size 44 providing & fixing of ip20 smd mid power led batten type integrated light fixture made from powder coated extruded aluminiumhousing with in built driver, system lumen efficacy = 110 lm / watt output, internal surge protection of 2.5 kv with short & open circuit protection , thd < 10% , p. f.=0.95, cri >80 , life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing on housing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 45 1170mm ( + / 10% ) led batten with min. lumen output 2200 lm 46 providing & fixing of ip 20 led recessed / surface mounted, round / sqauresmd mid power led downlight with power coated die cast aluminum housingwith uv stabilized non yellowish diffuser withbis complience 2.5 kv surge protected isolated driver, with short & open circuit protection, having efficiency > 85% . system lumen efficacy of = 110 lm / watt, thd < 10 % , pf.=0.95, cri >80, life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. 47 oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 48 recessed mounting 49 minimum lumen output 1300 lm 50 providing & fixing ofbeestar rated copper wounded double ball bearing capacitor start, aluminium body & metallicblade ceilingfanconforming to all the performance requirements laid down in is 374:2019 including all amendments, as applicable ; & carry bis licensing ( i.e. isi marking ) with down rod up to 80 cm with secondary support safety cable ( steel rope ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 51 1200 mm sweep bee 1 star rated ( service value >=4.0 to < 4.5 ) 52 providing & fixing of wall mounting / pedestal type heavy duty air circulator , double ball bearing and with metal sturdy mesh guard; aluminium alloy one piece blade and conforming to is:2997, including fixing with anchor bolts, making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 53 600 mm sweep wall mountingwith minimum air delivery 270 cum. / minute...

Public Works Department - Rajasthan

36407422 tender for electrical work in govt. janana hospital jhalawar wiring of light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) on surface isi marked ( is:14927 p ii ) virgin materialupvc trunking & its accessories, hot dipped galvanizedmodular box of 1.2 mm thickwith earth terminal / surface moulded virgin materialupvcmodular box , 10 a modular switch, modular faceplate with grid plate, 3 pin ceiling rose / holder / 3 way connector, screws, making connections, testing etc. as required. for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 2 short point ( up to 3 mtr. ) 3 medium point ( up to 6 mtr. ) 4 long point ( up to 10 mtr. ) 5 wiring of twin control light point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) of approved make on surfaceisi marked ( is:14927 p ii ) virgin materialupvc trunking & its accessories, hot dipped galvanizedmodular box of 1.2 mm thickwith earth terminal / surface 2 no. moulded virgin materialupvcmodular box , 2 nos 10 a two way modular switch, 3 pin ceiling rose / holder / 3 way connector , modular face plate with grid plate, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 6 medium point ( up to 6 mtr. ) 7 long point ( up to 10 mtr.. ) 8 wiring of 3 / 5 pin 6 amp. light plug point with 1.5 sq. mm nominal sizefr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) on surfaceisi marked ( is:14927 p ii ) virgin materialupvc trunking & its accessories, hot dipped galvanizedmodular box of 1.2 mm thickwith earth terminal / surface moulded virgin materialupvcmodular box, modular 10a switch, 3 / 5 pin6 amodular socket, modular face plate with grid plate, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 9 on board 10 s&f following sizesof isi marked ( is:14927 p ii ) virgin materialupvc trunking along with accessorieslike coupler, inner, outer, elbow, square box, tee, end cap etc. on surfacewithscrews, expansionfastenersas required. for additional technical parameters of product / work refer annexure a attached with this bsr 11 25 mm x 12 mm 12 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from99.90 % purity copper, class 5 stranding in acc. to is:8130 / iec 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation pvc type a / c / d , flame retardant as per is 10810 53, better amperage rating as per is:3961 part 5, in existingsurface or recessed pvc / ms conduit / casing capping making connections with copper lugs of suitable size, ferrules, testing etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of product / work refer annexure a attached with this bsr 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 p & f paper phenolic resin bondedlaminates confirming to is : 2036 1995 for boxes / frames including making holes for switches etc, with brass screws, washers / zinc platednut and bolts as required. for additional technical parameters of product / work refer annexure a attached with this bsr 16 3.0 mm thick 17 providing & fixing of 240 / 415 v ac mcb with positive isolation of 10 ka breaking capacity ( b / c / d tripping characteristic as per type of load andsite requirement ) 4 kv impulse withstand voltage, isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted inexisting distribution board / sheets, minimum electrical operation 20, 000 upto 20 a rating and 10, 000 upto 63 a, 5000 for 80 a & above ratingincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 18 single pole mcb ( with b / c curve tripping characteristics ) 19 6 a to 32 a rating 20 double pole mcb ( with b / c curve tripping characteristics ) 21 40 a rating 22 four pole mcb ( with b / c curve tripping characteristics ) 23 50 / 63 a rating 24 providing & fixing of recessed / surface mounting heavy duty horizontal type double door ( metal / glazed ) distribution board with metal end box made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3, powder painted complete with reversible door ( for double door db only ) 100 amp. insulated copper bus bar / shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar, masking sheet, making internal db terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 25 metal door ( single phase ) ik 09 and ip 43 with metal end box 26 4 way ( 4+2 ) 27 p & f isi marked ( is:3854 ) 6 amp. flush type non modular switchwith cm / l no. printed and made out from industrial grade polycarbonate or fire resistant abs material including cutting hole in tile and making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 28 p & f isi marked ( is :3854 ) 16 amp. flush type non modular switch cm / l no. printed and made out from industrial grade polycarbonate or fire resistant abs material including cutting hole in tile and making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 29 providing & fixing ofof 3 / 5 pin 6 amp. flush typenon modular socketmade out from industrial grade polycarbonate or fire resistant abs material, brass terminal with porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 30 providing & fixing of3 / 6 pin 16 amp flush type non modular socketmade out from industrial grade polycarbonate or fire resistant abs material, brass terminal with porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 31 sitc of3 / 4pole current limiting moulded case circuit breaker ( mccb ) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440 / 415 v, 50 hz; o / l & s / c settings , conforming to is / iec 60947 p 2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push ( test ) to trip, trip time less then 10 ms under s / c condition, breaking capacity ics = 100% icu. u imp =8 kv, rated insulation voltage690 v.provision for uvr , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.oem shall have submitnabl / cpri / erda accrediated lab type test certificate before execution all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 32 4 pole mccb with thermal magnetic release 33 125 amp , 25 ka, adjustable o / l & adjustable s / c setting, 34 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed arrmouredaluminiumcable confirming to is:1554 p i / is :7098 p i of 1.1 kv withh4 grade electrolyticaluminium conductor confirming to is 8130 of purity >99.6 %, round / flat strip armouring of cables, inner / outer sheath confirming to is:5831in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench / cable tray ( with cable tie ) includingtesting etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810.for additional technical parameters of product / work refer annexure a attached with this bsr 35 10.0 sq. mm 36 2 core 37 making of hole in wall ( brick / stone ) of required and placing np 2 rcc pipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 38 up to 457 mm size 39 providing & fixing of heavy duty capacitor start, copper wounddouble ball bearing900 / 1400 rpm single phaseexhaustfan conforming to is:2312 isi marked in existing opening including making connections testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 40 300 mm sweep ( 900 / 1400 rpm ) 41 380 mm sweep ( 900 / 1400 rpm ) 42 p & f of gravity louver shutter of superior quality made out of frame of18 swg m.s. sheet & louvers made from 24 swg ms sheetwith enamel paint including cost of nuts, bolts, etc as reqd.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 43 up to 380 mm size 44 providing & fixing of ip20 smd mid power led batten type integrated light fixture made from powder coated extruded aluminiumhousing with in built driver, system lumen efficacy = 110 lm / watt output, internal surge protection of 2.5 kv with short & open circuit protection , thd < 10% , p. f.=0.95, cri >80 , life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing on housing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 45 1170mm ( + / 10% ) led batten with min. lumen output 2200 lm 46 providing & fixing of ip 20 led recessed / surface mounted, round / sqauresmd mid power led downlight with power coated die cast aluminum housingwith uv stabilized non yellowish diffuser withbis complience 2.5 kv surge protected isolated driver, with short & open circuit protection, having efficiency > 85% . system lumen efficacy of = 110 lm / watt, thd < 10 % , pf.=0.95, cri >80, life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. 47 oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 48 recessed mounting 49 minimum lumen output 1300 lm 50 providing & fixing ofbeestar rated copper wounded double ball bearing capacitor start, aluminium body & metallicblade ceilingfanconforming to all the performance requirements laid down in is 374:2019 including all amendments, as applicable ; & carry bis licensing ( i.e. isi marking ) with down rod up to 80 cm with secondary support safety cable ( steel rope ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 51 1200 mm sweep bee 1 star rated ( service value >=4.0 to < 4.5 ) 52 providing & fixing of wall mounting / pedestal type heavy duty air circulator , double ball bearing and with metal sturdy mesh guard; aluminium alloy one piece blade and conforming to is:2997, including fixing with anchor bolts, making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 53 600 mm sweep wall mountingwith minimum air delivery 270 cum. / minute...

Rajasthan State Road Development And Construction Corporation Limited - Rajasthan

36350189 tender for electrification work of iti building at arain district ajmer wiring of light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked mms ( is:9537 p iii ) virgin material pvc conduit & itsisi marked ( is:3419 1988 ) accessories, round tiles, 1.2 mm thickhot dipped galvanized modular box with earth terminal, 10a modular switch, modular face plate with grid plate, 3 pin ceiling rose / holder / 3 way connector, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 3 short point ( up to 3 mtr. ) 4 medium point ( up to 6 mtr. ) 5 long point ( up to 10 mtr. ) 6 wiring of twin control light point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) in recessed isi markedmms ( is:9537 p iii ) pvc conduit & its isi marked ( is:3419 1988 ) accessories, round tiles, 2 nos hot dipped galvanized m.s modularbox of 1.2 mm thickwith earth terminal, 2 nos10 a two way modular switch, 3 pin ceiling rose / holder / 3 way connector , modular face plate with grid plate, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 7 long point ( up to 10 mtr. ) 8 wiring of 3 / 5 pin 6 amp. light plug point with 1.5 sq. mm nominal sizefr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked mms ( is:9537 p iii ) pvc conduit & its isi marked ( is:3419 1988 ) accessories, hot dipped galvanizedmodular box of 1.2 mm thick with earth terminal, 10 a modularswitch, 3 / 5 pin 6 a modular socket, modular face plate with grid plate, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 9 on board 10 short point ( up to 3 mtr. ) 11 medium point ( up to 6 mtr. ) 12 long point ( up to 10 mtr. ) 13 s&f following sizes ( dia. ) of isi marked virgin material mms ( is:9537 p iii ) pvc conduit along withisi marked ( is:3419 1988 ) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. for additional technical parameters of product / work refer annexure a attached with this bsr 14 20 mm 15 25 mm 16 32 mm 17 40 mm 18 50 mm 19 s&f following sizesof isi marked ( is:14927 p ii ) virgin materialupvc trunking along with accessorieslike coupler, inner, outer, elbow, square box, tee, end cap etc. on surfacewithscrews, expansionfastenersas required. for additional technical parameters of product / work refer annexure a attached with this bsr 20 100 mm x 50 mm 21 150 mm x 50 mm 22 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from99.90 % purity copper, class 5 stranding in acc. to is:8130 / iec 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation pvc type a / c / d , flame retardant as per is 10810 53, better amperage rating as per is:3961 part 5, in existingsurface or recessed pvc / ms conduit / casing capping making connections with copper lugs of suitable size, ferrules, testing etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of product / work refer annexure a attached with this bsr 23 1 x 1.5 sq.mm 24 2 x 1.5 sq.mm 25 3x 1.5 sq.mm 26 1x 2.5 sq.mm 27 2 x 2.5 sq. mm. + 1x1.5sqmm 28 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 29 2 x 6.0 sq. mm. + 1 x 4.0 sq. mm. 30 2 x 6.0 sq.mm 31 2 x 4.0 sq.mm 32 4 x 10.0 sq.mm 33 4 x 16.0 sq.mm 34 supplying and drawing pe insulated & pvc sheathed unarmoured telephone cable with 0.5 mm dia. solid annealed electrolytic grade bare copper conductor as per is: 8130 / 84 &confirming to tec specification gr / wir / 06 03 march 2002in existingsurface or recessed conduit / casing capping. including ferruling on each pair for identification etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 35 2 pair 36 supply and laying of pe insulated jelly filledarmouredtelephone cable. with 0.6 mm thick solid annealed bare copper conductor and confirming to tec specificationsconfirming. to dot gr / cug 01 / aug.2003 in existing pipe / open trench / cable tray / on surface including making necessary connection, testing etc. as required of size. for additional technical parameters of product / work refer annexure a attached with this bsr 37 10 pair 38 50 pair 39 supplying and drawing coaxial cable 75 ohm impedance with foam pe insulated solid bare copper inner conductor, and ist outer conductor of bonded alum. tape and second outer conductor ofalum. alloy braidin existingsurface or recessed conduit / casing capping including making connections as required. for additional technical parameters of product / work refer annexure a attached with this bsr 40 rg 6 41 p / laying isi marked p.v.c. insulated submersible cable confirming to ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from99.90 % purity copper, stranding in acc. to is:8130 / iec 60228 forlower watt loss , oxygen freefor less chances of oxidization, insulation pvc type a / c / d , flame retardant as per is 10810 53, better amperage rating as per is:3961 part 5, existing pipe / open trench / cable tray / on surface including making connection etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 42 2.5 sq.mm 3 core flat / round 43 4.0 sq.mm 3 core flat / round 44 6.0 sq.mm 3 core flat / round 45 p & f paper phenolic resin bondedlaminates confirming to is : 2036 1995 for boxes / frames including making holes for switches etc, with brass screws, washers / zinc platednut and bolts as required. for additional technical parameters of product / work refer annexure a attached with this bsr 46 3.0 mm thick 47 4.8 mm thick 48 6.4 mm thick 49 p & f 1.2mm thickm.s. recessed fan box, hexagonal / round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mmlength extended on each side . all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr 50 p & f krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted, including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 51 10 pairs 52 50 pairs 53 supplying and fixing of power plug point with modular accessories as per pwd specification for electrical works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal / connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofisi marked modular 16 amp. switch ( is :3854 ) and 6 / 16 amp. socket outlet ( is:1293 ) making connection , testing , etc. as required. for specification ofwiring accessories refer chaptere 07related item & for additional technical parameters of product / work refer annexure a attached with this bsr 54 p&f metal clad / plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain / bakelite base in recessed / surface mounting heavy duty enclosure made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3. powder painted ( without mcb ) including making connections, testing etc.as required.for additional technical parameters of product / work refer annexure a attached with this bsr 55 20 amp, 3 pin + scrapping earth, 4 module 56 32 amp, 5 pin + scrapping earth, 8 module 57 making of hole in wall ( brick / stone ) of required and placing np 2 rcc pipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 58 up to 457 mm size 59 providing & fixing ofextra down rod of 15 mm dia . erw ( electrical resistance welded ) of 1.6mm nominal thick medium duty steelpipe including cutting, threading, drilling, fixing quarter pin etc as reqd.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 60 providing & fixing of single / multi tone electronic call bell as per pwd specification for electrical works, including making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 61 providing & fixing of modular type switch / bell push duly isi marked ( is :3854 ) with cm / l no. printed and made out of unbreakable and fire retardant vergin uv stabilized polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , minimum width ofswitch toggle ( push part ) should not less then 20mm, includingall as per pre approved by engineer in charge, making connections, testing etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 62 10 a one way switch 63 32 amp. 2 moduleswitch with ledindicator 64 providing & fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , includingall as per pre approved by engineer in charge, making connections, testing etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 65 6 a3 / 5 pin shuttered socket 66 25 amp. 2 module socket 67 providing & fixing of modular type 120 w step fan regulator duly isi marked ( is 11037:1984 ) with cm / l no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , includingall as per pre approved by engineer in charge, making connections, testing etc. as required.for additional technical parameters of product / work refer annexure a attached with this bsr 68 5 step fan regulator 2 module 360 dgree rotating 69 providing & fixing of following modular accessories as per pwd specification for electrical works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , includingall as per pre approved by engineer in charge, making connections, testing etc. as required.for additional technical parameters of product / work refer annexure a attached with this bsr 70 t.v. coaxial socket 71 rj 11 telephone jack double line 72 blanking plate 73 modular mcb 6 a to 32 adp 74 providing & fixing offollowing size mounting grid plates with cover plates made from fire retardent uv established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 75 1 / 2 module 76 8 module 77 providing & fixing ofwiring accessories oem fabricated following size gi box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess / surface suitable for modular accessories as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 78 1 2 module 79 6 / 8 module 80 providing & fixing of ip20 smd mid power led batten type integrated light fixture made from powder coated extruded aluminiumhousing with in built driver, system lumen efficacy = 110 lm / watt output, internal surge protection of 2.5 kv with short & open circuit protection , thd < 10% , p. f.=0.95, cri >80 , life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing on housing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 81 1170mm ( + / 10% ) led batten with min. lumen output 2200 lm 82 570mm ( + / 10% ) batten with min. lumen output 1000 lm 83 providing & fixing of ip 20 led recessed / surface mounted, round / sqauresmd mid power led downlight with power coated die cast aluminum housingwith uv stabilized non yellowish diffuser withbis complience 2.5 kv surge protected isolated driver, with short & open circuit protection, having efficiency > 85% . system lumen efficacy of = 110 lm / watt, thd < 10 % , pf.=0.95, cri >80, life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. 84 oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 85 surface mounting ( with extruded alumn. housing ) 86 minimum lumen output 1300 lm 87 minimum lumen output 1950 lm 88 providing & fixing of ip20, 2x2 led surface / recessedmounting mid power smd type led light fixture not less than 50mm housing depth made from crca sheet steel housing, high purity / transmisivity uv stabilized non yellowish diffuser for uniform light distribution. high efficiency with 4 kv internal / external surge protection bis certified isolated driver having efficiency > 85% , with short & open circuit protection ( integral with light fixture ) . system lumen efficacy of = 120 lm / watt , thd < 10 % , p.f.=0.95, cri >80 , life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. 89 oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 90 surface moutning 91 minimum lumen output 4200 lm 92 providing & fixing of ip65 ik08 rated integrated smd mid power led bulk head type light fixture made from pressure die cast al housing suitable with integral driver, system lumen efficacy =100 lm / watt output , thd < 10% , p.f.=0.95, cri >80 , life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. surge protection 4 kv. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 93 minimum lumen output 1000 lm 94 providing & fixing of 400 mm sweepbldc technology oscillating type wall mounting / pedestal typefans with three speed, on andoff position, double wall bearing withfront and back 120 or moreribs guard; three no.blades, noise level should be <= 75 db, including fixing with anchor bolts, making connection testing etc. as required. ( with remote ) all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 95 wall mounting type with service value 2.0 cmm / w, min. air delivery 71 cmm 96 providing & fixing ofbeestar rated copper wounded double ball bearing capacitor start, aluminium body & metallicblade ceilingfanconforming to all the performance requirements laid down in is 374:2019 including all amendments, as applicable ; & carry bis licensing ( i.e. isi marking ) with down rod up to 80 cm with secondary support safety cable ( steel rope ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 97 1200 mm sweep bee 1 star rated ( service value >=4.0 to < 4.5 ) 98 providing & fixing ofof double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor , making connections, testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 99 300 mm sweep 100 providing & fixing of heavy duty capacitor start, copper wounddouble ball bearing900 / 1400 rpm single phaseexhaustfan conforming to is:2312 isi marked in existing opening including making connections testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 101 300 mm sweep ( 900 / 1400 rpm ) 102 380 mm sweep ( 900 / 1400 rpm ) 103 providing & fixing ofof ventilating fans capacitor start, copper wounded, single phase with pvc impeller, abs body, automatic openable louver shutter in existing opening including making connection, testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 104 150 mm sweep 105 250 mm sweep 106 p & f of wall cowl with bird screen suitable for outside wall of exhaust fan openingof following size and made out from 24 swg gi sheet as per instructions of engineer in chargeincluding fixing with suitable fasteners etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 107 suitable for 300 mm sweep exhaust fan 108 suitable for 380 mm sweep exhaust fan 109 providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket / pole. fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with uv stabilized pc ( uv stablization report submitted for uv cover ) / toughened glass coverand secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm / wt and potted driver& has a unique bis r number withinput voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driverefficiency >85%, thd ( i ) <10%humidity 10% to 90% rh working temp 5c to 45c .driver current <750ma. the luminaireshall be bis certified and trade mark certified. life expectancyequal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min = 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs.manufactures word mark / name engraved / embossing on die cast housing to allow traceability / authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities forled fixtures. ( lm79 / lm80 ) certificate / report with liable warranty of product / accessories from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 110 led street light fixture with minimum lumen output 11225 lm 111 supply and erection ofgalvanized iron pole with galvanizing done in single dipping ( average coating thickness minimum 65 microns ) continuously tapered poles having octagonal / circular cross sections designed to withstand the maximum wind speed as per is 875, the pole shaft shall be made from sheet steel ( ht steel conforming to grade s355jo ) and confirming to bsen 10025 and shall be continuously tapered with single longitudinal welding. there shall not be any circumferential welding. the welding of pole shaft shall be done by submerged arc welding ( saw ) process. pole shafts shall be provided with the rigid flange plate of suitable thickness ( fe 410 conforming to is 226 / is 2062 ) with provision for fixing 4 no. foundation bolts, this base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.the octagonal poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the base plate with bakelite sheet having 6a sp mcb and 16 sqmm stud type connector ( 4 nos ) inside the pole at door opening for cable connection of following length and dimension as per table p 01 with base plate and foundation bolt on the existing cement concrete foundation.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 112 poles with octagonal cross section 113 7 mtr. 114 supply and fixing of pole oem fabricated hot dipped galvanised m.s. overhang ( 48.3 x 3.25 mm ) with cap ( 400 x 88.9 / 114.3 x 3.25 mm ) over the existing poles. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 115 single arm overhang 116 providing and laying rcc foundation for octagonal / conical street light poles, high mast poles as per drawing attach at tablep 4with following procedure& all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 117 a ) excavation of pit for foundation size upto required depth from ground level 118 b ) dressing of pit and dry stone pitching 200 mm thick including supply of stones and preparing surface complete. 119 c ) providing and laying in position cement concrete of m 10 grade of 75 mm thickness 120 d ) reinforcement for r.c.c. work with tmt bars including straightening, cutting, bending, placing in position and binding all complete. 121 e ) centring and shuttering including strutting , propping etc. and removal of form work for footing and pedestal 122 f ) providing & fixing of 2 no. required sizeplb hdpe pipe& foundation bolt with template as per oem recommendations. 123 g ) providing and layingreinforce cement concrete of m 25 grade in footing and pedestal including curing the foundation for 7 days. 124 h ) providing and fixing nosing angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. lugs on each face. 125 pole foundation for octagonal pole from 7 mtr. to 9 mtr. 126 providing & fixing of ik08ip65 protected top / bottom mounted led post top luminarie made of single piece constructionpowder coated die cast alluminium housing with uv stabalized clear / frosted polycarbonate diffuser andaluminium anodised with sand blast reflector. the system level luminous efficacy =100 lumen / w. smd leds is to be used, system cri>70, cct: 3000 / 4000 / 6500 k. the integral electronic driver must be potted & has a unique bis r number must be potted & has a unique bis r number constant current and internal / external surge protection device of min. 4kv ( l n ) and efficiency > 85%, pf>0.9, thd<10% and input voltage range of 140 270v ac at 50hz. system life of 50000 burning hours with 70% of initial lumens maintained . driver current <750ma.fixture must be in compliance with bis standards and trade mark certificate complete in all respect.oem must have its own in house nabl lab setup for all testing facilities forled fixtures. ( lm79 / lm80 ) certificate / report with liable warranty of product / accessories from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 127 minimum lumen output 4500 lm post top luminarie 128 providing & fixing of street light bracket made out from following size of b class , medium class g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with heavy duty pole clamp, saddles suitable fastners etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 129 40 mm dia. 130 supply , installation, testing and comissioning of is:1475 marked self contained drinking water cooler withhermeticallysealed compressor, non cfc refrigerent suitable for operation on 230v / 1ph / 50hz ac supply, full stainless steel ( ss304 ) body ( 0.8 mm thick ) and tank ( 0.5 mm thick ) , stainless steel water tray, minimum two nosbrass chrome plated faucets and suitable drainage system complete in all respect with requiredheight ms fabricated and painted angle iron frame ( cost of frame to be paid extra ) complete in all respect of the following capacity.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 131 cooling capacity 150 ltr. / hr. and storage capacity 150 ltrs 132 providing and laying non pressure np 3 classr.c.c. pipes including collars / spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) etc. as required. ( excavation of earth& back filling with compaction is to be paid extra ) . all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 133 200 mm dia. 134 labour charges for excavating trenches of required width for pipes dressing of sides, ramming of bottoms, depth up to 1.5 mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 mtr.: 135 all kind of soils 136 sitc of wall type following zone ( each zoneaccessing minimum 20 units ( detectors / devices ) ) conventional type microprocessor based with lcd display en / lpcb / ul listed / approved main control panel fabricated from 16 swg crca sheet steel sealed maintenance free ( smf ) batteries of min2x7ah of 12 v or as required.including the cost of all accessories, etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 137 4 zone 138 sitcof en / lpcb / ul listed / approved conventional type manual call point resettable complete with glass, hammer and chain etc.including the cost of all accessories etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 139 sitc of en / lpcb / ul listed / approved conventional type hooter cum strobe including the cost of all accessories, etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 140 supply & fixing of water + afff 6%mechanical foam typefire extinguisher ( stored pressure type ) conforming to is:15683:2018 , powder coated internal & external surface deep drawn cylinder body of mild steel cr2 grade conforming to is: 513, squeeze grip forged brass release valve with inbuilt safety release device, diaphragm type, 0 to 25 bar range pressure gauge, 450 mm long epdm discharge tube, qr code for product traceability including fixing on wall with suitable anchor fasteners as required of following capacity. test certificates of all the parameters along with hydro test & burst test ( for cylinder body ) certificatefrom oem / external nabl accrediated lab is to be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 141 capacity 6 ltrs. 142 supply & fixing of co2 type fire extinguisher conforming to is:15683:2018, charged with co2 gas ( purity 99.7% conforming to is 15222 ) , powder coated internal & external surface manganese steel isi marked as per is 7285 cylinder body , wheel type forged brass release valve isi marked as per is 3224 with inbuilt safety release device ( ( fusible plug and rupture disc type ) , 1.0 mtr. metal wire braided hose having minimum bursting pressure of 140 kgf / cm2, horn with metallic thread connection, qr code for product traceability, including fixing on wall with suitable anchor fasteners as required of following capacity. test certificates of all the parameters along with hydro test & burst test ( for cylinder body ) certificatefrom oem / external nabl accrediated lab is to be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 143 capacity 4.5 kg. 144 supply & fixing of dry powder agent ( as per is 4308:2019 ) , abc typefire extinguisher ( stored pressure type ) conforming to is:15683:2018 , powder coated internal & external surface deep drawn cylinder body of mild steel cr2 grade conforming to is: 513, squeeze grip forged brass release valve with inbuilt safety release device, diaphragm type, 0 to 28 bar range pressure gauge, 450 mm long epdm discharge tube, qr code for product traceability including fixing on wall with suitable anchor fasteners as required of following capacity. test certificates of all the parameters along with hydro test & burst test ( for cylinder body ) certificatefrom oem / external nabl accrediated lab is to be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 145 4 kg 146 supply , installation, testing and comissioning ofinverter type air cooled hi wall split type air conditioners with latest star rating system as per bee amended upto date complete with indoor unit ( idu ) , out door unit ( odu ) , surface / concealed copper refrigerant piping with insulation ( closed cell elastomeric nitrile rubber tubular pipe section ) upto 3 mtr ( idu to odu ) , copper power cable upto 3.5 mtr ( idu to odu ) , r 32 / r 410 green refrigerant, wireless remote control, suitable for working between 230v + / 10% with low & high voltage cutoff and50 hz , single phaseacsupply capable of performing cooling, dehumidification, air circulation of following capacity with scroll / rotary compressor. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 147 1.5 tr iseer not less then 4.6 148 2.0 tr iseer not less then 4.6 149 providing & fixing of is : 4985 2000 class 4 ( 10 kgf / sqcm ) upvc drain water piping withfittings ( is:7834 & 10kgf / sqcm ) like elbow, socket, tee, solvent cement jointing, support with ms hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following nominal sizes. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 150 25 mm 151 supply, fixing and testing of following capacity iso certified company made wall mounted stabilizer having output voltage variation from 200 v to 250 v ( + / 5% ) with input voltage variation from 170 v to 260 v, time delay facility from 2 to 4 minute and high cutoff at 270 v with providing of 16 amp / 20 amp industrialplug top making connection etc complete in all respect.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 152 4 kva 153 5 kva 154 making hole in stone masonary / rcc wall / rcc slab with core cutter for accomodating refrigerant pipe / drain pipe / ms pipe / cables etc of following dia 155 50 mm dia per running inch length 156 supply & fixing ms powder coated stand suitable for 1.0 / 1.5 / 2.0 tr outdoor type of split ac.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 157 sitc of interconnecting refrigerantcopper pipe forsplit / ductable / casseette ac of dhe grade c12200 astm b68, b75, chemical composition of copper % 99.0 min and phosphorus % 0.015 to 0.040 . for annealed copper tube : tensile strength = 210 mpa wih elongation % = 40 min . ink markbrand printing on hard tubes should be present. piping between each set of indoor & outdoor units of different sizesas per oem requirement & specifications including class o nitrile rubber sleeves, chase cutting, supports, making good the same with sand cement plaster etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 158 supplying and drawing flexible / stranded bare copper conductor, pvc / xlpe insulated, overall aluminium mylar tape shielded atc drain wire and outer pvc sheathed industrial instrumentation ( shielded ) cables voltage grade 300 / 500 v as per bs / en 50288 7 in existingsurface or recessed pvc / ms conduit / casing capping / cable tray / open duct making connections, testing etc. as required. oem must have its own in house nabl lab setup for all testing facilities for cables. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 159 un armoured 160 4 core x 2.5 sq.mm 161 providing & fixing of 240 / 415 v ac mcb with positive isolation of 10 ka breaking capacity ( b / c / d tripping characteristic as per type of load andsite requirement ) 4 kv impulse withstand voltage, isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted inexisting distribution board / sheets, minimum electrical operation 20, 000 upto 20 a rating and 10, 000 upto 63 a, 5000 for 80 a & above ratingincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 162 single pole mcb ( with b / c curve tripping characteristics ) 163 0.5 a to 5 a rating 164 6 a to 32 a rating 165 double pole mcb ( with b / c curve tripping characteristics ) 166 50 / 63 a rating 167 triple pole mcb ( with d curve tripping characteristics ) 168 6 a to 32 a rating 169 50 / 63 a rating 170 four pole mcb ( with b / c curve tripping characteristics ) 171 50 / 63 a rating 172 40 a rating 173 providing & fixing of 240 / 415 v residual current circuit breaker ( rccb ) conforming to ( is:12640 1 ) / iec 61008 1 , rated 4 kv impulse withstand voltage truly current operated and shall operate on cbct mechanisum, provision for pad lock, min. operation 10, 000 upto 63 a rating and5000 for 100 aratingand minimum phase termination capacity of 35 sq.mm. rigid wire, ip 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 174 two pole 100 / 300ma sensitivity 175 40 a rating 176 63 a rating 177 providing & fixing of recessed / surface mounting heavy duty horizontal type double door ( metal / glazed ) distribution board with metal end box made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3, powder painted complete with reversible door ( for double door db only ) 100 amp. insulated copper bus bar / shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar, masking sheet, making internal db terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 178 glazed door ( single phase ) ik 09 and ip 43 with metal end box 179 12 way ( 12+2 ) 180 metal door ( three phase ) per phase isolation, horizontal ik 09 and ip 43 with metal end box 181 4way ( incomer 8, sub incomer2+2+2 ) 182 6way ( incomer 8, sub incomer2+2+2 ) 183 8way ( incomer 8, sub incomer2+2+2 ) 184 12 way ( incomer 8, sub incomer2+2+2 ) 185 providing & fixing of recessed / surface mounting heavy duty vertical tpn distribution board with metal end box with provision of incomer suitable for 3 / 4 pole mccb and sp / tp mcb as outgoing , made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3. powder painted with reversible door ( for double door db only ) complete with insulated 160 ( upto 160 a incomer ) / 250 amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar, masking sheet, making internal db terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr 186 double door ip 43 & ik 09 with provision of incomer mccb 100 / 125 a rating with metal end box 187 4 way 188 6 way 189 8 way 190 12 way 191 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed arrmouredaluminiumcable confirming to is:1554 p i / is :7098 p i of 1.1 kv withh4 grade electrolyticaluminium conductor confirming to is 8130 of purity >99.6 %, round / flat strip armouring of cables, inner / outer sheath confirming to is:5831in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench / cable tray ( with cable tie ) includingtesting etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810.for additional technical parameters of product / work refer annexure a attached with this bsr 192 6.0 sq. mm 193 4 core 194 10.0 sq. mm 195 4 core 196 16.0 sq. mm 197 4 core 198 35.0 sq. mm 199 3.5 core 200 70.0 sq. mm 201 3.5 core 202 95.0 sq. mm 203 3.5 core 204 185.0 sq. mm 205 3.5 core 206 add extra for laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv gradedirect in ground including excavation of trench of size 75 cm ( depth ) x 35 cm ( width ) , with procedure as per followingpoints: ( a ) make a river sand bed of height 125 mm along the trench, ( b ) lay the cable in the middle of the trench, ( c ) provide river sand bed of height 125 mm on top of the cable, ( d ) lay the protective common burnt clay f.p.s. bricks of class designation 75 / sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( approx. 9 no. bricks per mtr. ) , ( e ) backfill the excavated soil leaving 300 mm from the ground level, ( f ) lay the cable warning tape and again back fill the remaining portion of the trench upto the ground level and compacting the earth 207 add extra for laying of one number additional pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv gradedirect in ground in the same trench in one tier horizontal formation including excavation of trench of size additional 20 cm in width, with procedure as per following points : ( a ) make a river sand bed of height 125 mm along the trench, ( b ) lay another cable in middle of trench in such manner that spacing between another cable is 20 cm., ( c ) provide river sand bed of height 125 mm on top of the cable. ( d ) lay the protective common burnt clay f.p.s. bricks of class designation 75 / sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( approx. 9 no. bricks per mtr. ) , ( e ) backfill the excavated soil leaving 300 mm from the ground level, ( f ) lay the cable warning tape and again back fill the remaining portion of the trench upto the ground level and compacting the earth. 208 supplying and making one end termination with nickel plated heavy duty brass single compression gland ( as per is 12943 1990 ) ) sibg type consisting of check nut, gland body, metal washer ( 3 nos. ) , outer seal rubber ring, compression nut, heavy duty aluminium lugs ( as per is 8309 1993 ) duly crimped with crimping tool, pvc tape as peris 8337 1976offollowing size ofpvc insulated & pvc sheathed / xlpe aluminium conductor cable of 1100 volt grade as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 209 3.5 x 185.0 sq.mm 210 3.5 x 95.0 sq.mm 211 3.5 x 70.0 sq.mm 212 3.5 x 35.0 sq.mm 213 4 x 16.0 sq.mm 214 4 x 10.0 sq.mm 215 4 x 6.0 sq.mm 216 supply, fabricating & installing following sizes of perforated hot dipped galvanized iron cable tray ( galvanized thickness not less then 50 microns ) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees, cross members and other accessories as required and duly suspended from the ceiling with gi suspenders including gi bolts & nuts , fastners, supports etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 217 150mm x 50mm x 1.6mm 218 p / l of double wall corrugated hdpe pipe confirming to is : 16205 p 24, stiffness class750 n, externally corrugated and having smooth surface insidewith hdpe coupler, elbow, teeat required depth below the ground for laying cable of followingnominal outer dia.mfr test reportfrom nabl accrediated is to be submitted. ( excavation of earth& back filling with compaction is to be paid extra ) all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 219 50 mm 220 110 mm 221 plate earthing as per is:3043 withcopper earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying3 mtr. below the ground level with 20mm dia. g.i. b class watering pipe , including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke / charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 222 supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % copperthickness ( 250 microns ) andconfirming toul 467, is / iec 62561 2of following size and length and as per point mentioned ( a ) , ( b ) , [ c ) , ( d ) , ( e ) below : 223 ( a ) bore a hole of dia. 100 mm of required length, place the rod in the centre of hole 224 ( b ) filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, cpri / erdatested with rms capacity of minimum 30 ka for withstanding 1 second .to ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. the compound shall be tested form nabl acredeated labfor lowresistivity ( less than 0.12 ohm meter ) & high conductivity in nature with carbon as a major contentas per referance of is 3043 1987, ieee 80 2013 ( clause 14.5d ) , ieee 837 & ier 1956 with latest amendemnts 225 © connect the rod with copper strip / conductor / wire with suitable clamp made from tinned copper and ss 304 bolt 226 ( d ) place heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height250 to 300 mm. 227 ( d ) testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 228 ( e ) test certificatesfor confirming above standards from oem is mandatory. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 229 25 mm thick and 3 mtr. long 230 supply & laying following size earth stripin horizontal or vertical run in surface by means of earth strip dmc insulatorincluding riveting / soldering / welding, jointing shall be done by overlapping and with 2 set of brass ( for cu strip ) / gi ( for gi strip ) nut bolt & spring washer spaced at 50cm making connection etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 231 25mm x 3mm g.i. ( hot dipped ) strip 232 50mm x 6mm g.i. ( hot dipped ) strip 233 40mm x 6mm copper strip 234 supply & laying following size b class , g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor / strip / cable in ground / surface / recess as required.all as per pre approved by engineer in charge. ( earth excavation will be paid extra ) all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annex ure a attached with this bsr . 235 50 mm dia. 236 65 mm dia. 237 80 mm dia. 238 100 mm dia. 239 150 mm dia. 240 supply & laying following size earth wire in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection with gi / cu purity purity >95%thimble etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 241 8 swg g.i. ( hot dipped ) wire 242 supply, drawing and testing of 4 pair, 23 awg solid bare copper wire insulated with pvc, utp ( unshielded twisted pair ) , category 6, class e, 100 ohm impedance, indoor cable as per latest ammendments of ansi / tia / eia 568 , the copper conductors should be balanced twisted in pairs, seperated by a cross member fluted pair divider & protected bypvc jacket. certified performance in a 4 connector configuration upto 100 mtrs channel requirements & transmission frequencies up to 250 mhz. in existing ms / pvc conduits / casing capping including making connections to information outlets and patch panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 243 supply and installation of unsheilded / 360 degree sheilded information outlets made of high impact plastic body with abs, fr grade halogen free material with provision for protection against dust in jack, suitable for cat 6 / 6a application complying to latest ammendments, according. to cat. 6 / 6a channel, it should support channel as well as components requirements of cat.6 / 6a standards at frequencies of up to 250 to 500 mhz. cat 6 / 6a unshielded / shielded jack should be suitable to terminate 4 pair, 23 / 24 awg solid / stranded wire diameters, using 100 ohm unshielded / shielded balance twisted pair cable, the jack should have tooless / impact termination on reliable copper tin plated insulation displacement contact, with easy lock mechanism, it supports iec 60603 7 4 and complied with ansi / tia / eia 568 c.2 standard. jack should be rj11, rj12 & rj45 compatible. should support ethernet 1.2 gb / s atm, digital video and broadband / baseband analog video, voice over internet protocal ( voip ) specifications in existing modular / ms boxes along with necessory connections as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 244 cat 6, un sheilded information outlet 245 supply & fixing of square faceplate for flush / surface mount information outlets single / dual or quad aperture , material should bepc+abs body, suitable for rj45 unshielded / shielded connection modules. should match with i. o. oem. dimensions should be 86mm x 86mm as required complete in all respect.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 246 single aperture 247 supply, installation, testing and comissioning of rack mounted 19 1u, cat6 24 port loaded, 1.5 1.6 mm crs chasis, powder coated, sheet steel, made of plastic ( abs ) , modular patch panelswith rear cable management system and mounting hardware to mount the patch panel. should have port identification numbers printed / engraved on front of the panel. etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 248 modular patch panel loaded with cat 6 i / o 249 supply , installation and testing of 4 pair, 100 ohm impedance, cat 6 / 6a / class e / ea patch cords should be constructed of minimum 23 / 24 awg, stranded bare copper cable with frpvc / lszh jacket, with an enhanced performance by factory moulded rj45 connectors with strain relief boots as per ansi / tia / eia 568 c.2 suitable for cat 6 / 6a application complying to latest ammendments category 6 / 6a standards, according. to tia568c.2, iso / iec 11801, en 50173, iec 60603 7 51, en 60603 7, ieee 802.3an minimum requirement for 1g base t to 10g base t performance. patch cords shall be straight thru cable compatible with both t568 a and t568 b wiring schemes, should support ieee 802.3af / ieee 802.3at for poe applications, minimum 750 to 1000 mating cycles in plug contacts for long durability, should support ethernet 10gbase t, 1.2 gb / s atm, token ring 4 / 16, digital video and broadband / baseband analog video, voice over internet protocal ( voip ) .all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 250 cat 6, u / utp ( unscreened / un sheilded twisted pair ) patch cord 251 1 mtr 252 2 mtr 253 supply & installation of ip 20 & ik 08 , ul listedwall mounted double section communication enclosure ( rack ) made from powder coated ( 60 to 80 micron ) crca sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door, vertical mounting rail 1.6 mm with umarking , with all round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. accessories like: 1 no of 19 1u horizontal cable manager, 1 no of 90 cfm 230v ac fan with 1 mts long cable, mounting hardware , 1 no of 19 1u, mountable socket strips with 5 nos of 5a universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with suitable anchor fastneretc as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 254 15 u rack with width 600 mm & depth 400 mm + 100 mm 255 supply & installation of ip 20 & ik 08 , ul listed communication enclosure ( rack ) made from powder coated ( 60 to 80 micron ) crca sheet, vertical mounting rail 1.6 mm with umarking, front sturdy sheet steel frame folded from one piece and welded with 5mm toughened glass door, with all round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, set of 75 mm height 4 castors, 2 of which have brakes, accessories like: 5 nos of 19 1u horizontal cable manager, 2 nos of vertical cable managers, 1 no. keyboard tray, 4 nos of 90 cfm 230v ac fan with 1 mts long cable, mounting hardware , 2 no of 19 1u, mountable socket strips with 6 nos of 5a universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 256 27 u rack with width 600 mm &depth 800 mm 257 supply , installation, testing and comissioning ofmanaged layer 2 intelligent 10 / 100 ethernet switch providing 24 x 10 / 100 / 1000 mbps giga ethernet ports / with min 2 sfp giga ports ( provision for fiber giga connectivity ) with related lan base software including making connections etc as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 258 providing & laying xlpe insulated three core armouredaluminiumcable for working voltage 11 k.v. ( e ) confirming is :7098 p 2withh4 grade electrolyticaluminium conductor confirming to is: 8130 class 2 of purity >99.6 %, insulation screening: extruded semiconducting compound followed by helically wrapped copper tape, round / flat strip armouring of cables , inner / outer sheath pvc type st 2 confirming to is:5831in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench / cable tray includingtesting etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810 all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 259 3 core 185.0 sq.mm 260 add extra for laying of one number xlpe power cable of 11 / 33 kv ( earthed ) voltage gradedirect in ground including excavation of trench of size 120 cm ( depth ) x 35 cm ( width ) , with procedure as per followingpoints: ( a ) make a river sand bed of height 125 mm along the trench, ( b ) lay the cable in the middle of the trench, ( c ) provide river sand bed of height 125 mm on top of the cable. ( d ) lay the protective common burnt clay f.p.s. bricks of class designation 75 / sand stone slabs of 50 mm thicknessand 225 mm wide just above the sand bed vertically across the cable ( approx. 9 no. bricks per mtr. ) , ( e ) backfill the excavated soil leaving 300 mm from the ground level, ( f ) lay the cable warning tape and again back fill the remaining portion of the trench upto the ground level and compacting the earth 261 providing & making heat shrinkable type indoor / outdoor / straight through terminations / joint kitsuitable for11 kv / 33 kv ( earthed ) cable with required components, prepration of cable ends. type test report should be as per is13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streightthrough joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. crosslinking shall be done out side factory with e beam / peroxide technology. extrusion process shall be in house oem within same vicinity. includingtesting etc. as required of following sizes. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 262 11 kv end termination kit indoor type 263 3 core 120 / 150 / 185 sq.mm 264 11 kv end termination kit outdoor type 265 3 core 120 / 150 / 185 sq.mm 266 providing & fixing of iso certified company made on load change over switch, front handle operated, four pole 415 v as per pwd specificationfor electrical works conforming to is / lec 60947 3 : 1999 including connections , testing etc. as required .in the following rating.appropriate type test certificate / oem test report shall be submitted .all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 267 open execution type 268 200 a 269 sitc of ip 42 and general construction confirming to is:8623 : 1993, wall / free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andother parameters requiredas per point ( a ) , ( b ) , ( c ) , ( d ) , ( e ) , ( f ) , ( g ) , ( h ) as below: 270 ( a ) thickness of crca sheet shallbe 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 271 ( b ) complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel.the panel having pe foam / neoprene rubber gasket of not less than 3mm thickness , required hardware , concealed hinged door with key type locking arrangement for equipment / switchgear earthed with 2.5 sq.mm braided copper wire. 272 [ c ) interconnection between bus bar and switchgears / cable shall be rigidly supported and made out by flexible copper wires ( up to 63 amp ) and by solid bus bar ( >63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only.all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgearis to be paid extra ) 273 ( d ) wiring between components within switchgear and incoming / outgoing cableshall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 274 ( e ) all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be ‘point to point’ ( no wire splitting or tee connections ) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 275 ( f ) floor mounted panel shall be mounted on base frame of ismcchannel size 100 x 50 x 5 mm ( to be paid extra ) 276 ( g ) tests: the insulation resistance ( with 1000 v megger ) and high voltage power frequency test ( by applying a voltage of 2.5kv for one minute ) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. the insulation resistance shall not be less than three megaohm. ct secondary current injection test shall also be carried out. 277 ( h ) only outer surface area on all sides shall be measured & panel to be fabricated only from cpri approved fabricator only ( cpri test certificates to be submitted ) all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 278 supplying and fixing of aluminium ( iec 60105 iso 209 1, 2 ) / copper ( iec 60028 ) bus bar by means of smc / dmc type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 279 electrolytic grade aluminium bus bar 6010 grade 280 providing & fixing of is: 13875 & iec :61326 confirming led digital type ( up to 500 ) v range volt meter / direct ammeter / ct oertated ammeter / frequency meter / kwh meter / multi function meter / power analyzer of class 1 accuracyas per is : 1248 of size 96mm x 96 mm including making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 281 threephase amp+hz+pf+kw+kva+kvar+t.energy+thd i, thd v & run hrs 282 providing & fixing of bis approvedcurrent transformeras per pwd specification for electrical works , isi marked as peris 2705 1992 / conforming to iec 60044 1, with secondary terminalof ct shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredcurrent transformer ring type tape wound / resin cast wound as per is 16227 with, accuracy cl, ct ratio and burden as specified. isf<=5, cu cross section of secondary wire 1.5sqmm ( minimum ) , including all necessary support in existing panel including connection etc. as required . all as per pre approved by engineer in charge.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 283 ring type tape wound ct 284 c t class 1, ratio 200 / 5 to 300 / 5, burden 10 va 285 c t class 1, ratio 400 / 5 to 1200 / 5, burden 15 va 286 providing & fixing ofcam operated rotary ( auto / manual ) switches on existing panel with 2 way and off position using high grade engineering materialto international standards with cam assemblyinsulation of glass filled polyamide with high tracking index. for reliable and stable electrical and mechanical endurance double butt contacts with silver bi metal on copper should provided . contact assembly is of operating temp range 25 degree c to 55 degree c, frequency upto 10 khz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles / hour and electrically 10, 000 operations at 100% rated duty for 100 cycles / hour including making connection etc.as required . all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 287 32 amp 288 providing & fixing of110 / 220 v, unibody led indicatinglamp iec 60947with integral circuit, ip 65 above panel &ip 20 terminal block, approx. body dia for panel not less then 20 mm, length min. 50mm, front led cover dia min.29 mm, contact material phospher bronze for led, pcb contacts shall be ofbrass ( tin plated ) , impulsedielectric tested for 2.5 kv, rated insulation resistance shall be 100 m ohm at 500vdcincluding connection etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 289 red / yellow / green colour 290 blue / white colour 291 providing & fixing of electricalinsulating rubber matts as per pwd specification for electrical works, isi marked confirming to is: 15652 / 2006with one sideanti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 292 11 kv, class b 2.5 mm thick with proof voltage 22 kv ac ( rms ) and break down voltage45 kv ac ( rms ) 293 providing & fixing of self healing ip20 mpp type shunt capacitor ( banks ) conforming to is:13340 41 / iec :831 1&2 or iec : 60831 1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( psd ) and shall have dissipation factor less than 0.0025 at 50 hz, operating loss less than 0.30 watt per kvar. min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, llife expectancy greater than 100000hrs ( temp class 25 d ) in 440 v / 480 v capacitor and for 525 v should life expectancy minimum 1, 65, 000 hrs ( temp class 25 d ) including making connections, testing etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 294 heavy dutythree phase 525v, 50 hzcylindrical typecapacitor ( bank ) 295 providing & fixing of ip54 microprocessor based 3 ct’s for all 3 phasesensing compensationpower factor correction relay size 139mm x 139 mm, operating voltage 415 / 440 v, iec / en 61000 6 ( 2&4 ) having 3 ct sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c / k setting according to targeted power factor setting, the relay shall havedigit display unit for display of real power factor, targeted power factor, lag / lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with rs 485, indication of switching on units, auto / manual status, and shall have over load protection, no volt release , having multi parameter like kw, kva, kvar, rms value, step switching time 2 sec to 1800 sec. lead & lag parameters, metering facility and3 no. class 0.5 cast resinct ( refer ct specs in this chapter ) for sensing the relay including making coonection with 1.5 sq.mm copper wire etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 296 12 to 14 stage 297 providing & fixing ofac operated heavy duty 230 / 440 volt power contactor as per pwd specification for electrical works, isi marked is / iec 60947 4 1 : 2000 having provision of mechanical interlocking, auxilary contacts, din rail mounting type including making connections, testing etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 298 3 pole power contactorswith following ac 3 rating 299 40 amp 300 providing & fixing of440 volt 3 pole capacitor ( ac 6 b ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors / reactors to limit the inrush current as per pwd specification for electrical works, is / iec 60947 4 1 : 2000, insulation voltage 1000v, impulse withstand voltage 8 kv, din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 301 up to 6 kvar 302 10 kvar 303 20.0 kvar 304 providing & fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and ac1 rating of 16 20 amperes including making connection, programming conforming to iec 60730 1 and 60730 2 7 etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 305 one day & week reserve ( digital type ) 306 sitc of3 / 4pole current limiting moulded case circuit breaker ( mccb ) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440 / 415 v, 50 hz; o / l & s / c settings , conforming to is / iec 60947 p 2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push ( test ) to trip, trip time less then 10 ms under s / c condition, breaking capacity ics = 100% icu. u imp =8 kv, rated insulation voltage690 v.provision for uvr , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.oem shall have submitnabl / cpri / erda accrediated lab type test certificate before execution all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 307 3 pole mccb with thermal magnetic release 308 160 amp , 25 ka, adjustable o / l & adjustable s / c setting, 309 4 pole mccb with thermal magnetic release 310 up to 100 amp , 25 ka, adjustable o / l & adjustable s / c setting, 311 125 amp , 25 ka, adjustable o / l & adjustable s / c setting, 312 160 amp , 25 ka, adjustable o / l & adjustable s / c setting, 313 200 amp , 25 ka, adjustable o / l & adjustable s / c setting, 314 250 amp , 35 ka, adjustable o / l & adjustable s / c setting, 315 400 amp , 35 ka, adjustable o / l & adjustable s / c setting, 316 s i t c of star ratedaluminium wound distribution transformerof following rating 11 / 0.433kv delta star connected, vector group dyn 11, onan cooled & as per bee star 1 & bis approved as per is 2026 1977 & lossesas defined as per 2014 ( fourth revision ) level 1 . including standardaccessories like conservator, silica gel breather, radiator, fins, ht cable box & lt cable boxes, temperature rise in winding / oil 35 40 degree c upto 200 kva & 40 45 degree c for above 200 kva, isi marked drain valve, dial type temperature gauge, first filling of transformer oil as per is :335 1953, epoxy based paint, including carrying of pre commission testing & charging of transformer complete in all respect . 317 the transformer shall be subjected to routine factory tests ( as per is:2026 and is:1180 ) including testing from ctlof discombefore charging of transformer & complete installaion must be certified from electrical inspectorate office as per indian electricity rule, ( ctl testing charges and electrical inspection charges shall be reimbursed by the department to the contractor ) . all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 318 250 kva with off ltc ( +5% to 10% @ 2.5% ) 319 sitc of 11kv 630 amps 21ka for 3 sec. sf6 insulated, outdoor duty ( ip54 ) , extensible / non extensible typering main unit ( rmu ) manually operated in combination ofvcb modules andload break switch consisting of copper busbar in sf6 insulated 304 ( non ferrite non magnetic grade ) stainless steel enclosure of thickness 2.5mm with manometer.the hv switchgear and control gear should be confirming to iec 62271 100, iec 62271 200 2003 & iec 60694 1996. the rmu should be internal arc tested for 21ka for 1second with iac afl classification for gas tank. vacum interrupter of vcb should be rmu manufacturer’s own make.each feeder of rmu should have voltage presence indicator. . and compring offollowings: 1 no. microprocessor based self powered numerical relay with over current / earth fault & short circuit protection with each vcb feeder. 3 nos. protection ct shall be of burden 2.5va, ratio 50 / 1a, class of accuracy class 5p10for o / c and e / f protection for each vcb. 1 no. manometer for each tank, 1 nos. fault passage indicator, right angle boots for all the feeder modulesall the type test certificates as per iec from third partynabl / cpri / erda accrediated lab to be submitted. ( cost of rcc foundation / steel structure to be paid extra ) all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr 320 non extensible 3 way rmu with 1 no. vcb & 2 no. load break switch 321 sitc of ht metering cubical panel as approved by discoms fabricated out of 18 swg crca sheet steel in two compartment & ms angle of size 60mmx 6mm having provision for following: ( i ) provision for fixing trivector / import export meter ( to be supplied by discoms ) ( ii ) provision for fixing of combined ct pt set with copper strip for connection ( to be supplied by discoms ) , ( iii ) test terminal block, ( iv ) 6mm thick bakelite sheet on all sides, ( v ) 3 / 6 corex 1.5 / 2.5 sq.mm copper cable for interconnections, etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 322 sitc of radiator cooled and turbo charged silent dg set ( as per latest cpcb emissionnorms ) havingspecifications as per a, b, c, d, e, f, g, h & i 323 a ) 1500 rpm diesel engine conforming to bs:649 / 5514 of suitable bhp ( up to 82.5 kva 6 cylinder or below required, 125 kva & above ratings 6 cylinder or aboverequired ) capable of taking 10% over loading for one hour after 12 hours of continuous operation., dry exhaust mainfold with hospital grade silencer and catalytic convertor ( isolated from main dg chamber ) , up to 3 m exhaust piping ( with lrb insulation & alum. cladding ) as required . 324 b ) ac brush less spdp alternator conform to bs 5000 ( part 99 ) or is / iec 60034 1. . alternator shall be self regulated with standard alternator protection ( over voltage , over speed & under voltage, under speed warning & shutdown ) .engine & alternator mounted on a common base frame & coupled through a flexible coupling or close coupled 325 c ) cpcb / arai approved standard canopy with weatherproof, powdercoated accoustic enclosure for dg set for sound attenuation fabricated from 1.6 mm crca sheet steel ( structure ) with sidewall fabricated from 1.6 mm crca sheet & filled with glasswool ( 96kg / m3 ) / foam. as per is8183 the doors of 28 / 40 / 50 / 85mm thick as perrating and fabricated from 1.6mm crca sheet packed with accoustic material, all doors / opening are sealed with neoprene / epdngaskets. the dg set has inbuilt / external in fuel tank to run 6 to 8 hrs as per oem standard, with protection and tripping of dg set against temperature of more than 50 degree centigrade. 326 d ) electronic / mechanical governor, manual & electric start , batteries with battry charger, engine instruments panel, avm pads all controls for operation of dg set are from outside the enclosure with dg control panel having microprocessor based genset monitoring like running hour, rpm, low lube oil tripping & control system, panel mounted mccb / acb of suitable rating, ammeter, voltmeter, pf meter, frequency meter, kwh meter, digital fuel display meter, ind.lamps etc. mounted inside enclosure , visible and accessible from outside. the enclosure should be suitable for following capacity dg sets and alternator. noise level shall be less than 75 db at a distance of 1 mtrs. duly certified by authorised agency etc. complete in all respect of following capacity : 327 e ) ( i ) accoustic glass wool wall thickness should not be less then 40mm and not less then 20mm pu foam upto rating 100 kva. ( ii ) .accoustic glass wool wall thickness should not be less then 65mm and not less then 50mm pu foam upto rating 250 kva. ( iii ) accoustic glass wool wall thickness should not be less then 100mm forrating above 250 kva. 328 f ) first filling of the fuel tank shall be done by contractor and the prevailing fuel cost at that time shall be reimbursed to the contactor by department. 329 g ) servicing contract of dg set from oems authorised service dealer as per oem guidelines during the dlp period shall be done by contractor including all consumables, actual charges shall be reimbursed to the contractor by end user department. 330 h ) manufacturer / oem must have its authorized service dealer in rajasthan. which can provide service within 6 hours of compalint registration. 331 i ) dg set will be offered for inspection and testing at manufacturers works in presence of departmental engineers. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 332 40 kva at 0.8 pf 415v 50hz 3 ? 333 sitc of plc based auto main failure ( amf ) panel fabricated from crca sheet steel 2 mmthick , powder coated finish , engine start & stopcommands, control relays , ammeter & voltmeterwith selector switches, control & 2 nos 4 pole power contactors with 2 no. of required size 4 pole mccb, timers, electronic hooter , visual & alarm indication for faults, ups, operator interface panel complete in all respect suitable for following capacity dg sets: appropriate test certificate / report of product / accessories from oem / panel manufecturer shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 334 20 to 40 kva 335 supply & fabrication steel structure with ms channel / angle / joist / ismb / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as requiredcomplete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 336 providing and fixing welded mesh / expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 x 50 x 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 ( 30x30x45cm ) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 337 earth work in excavation / by mechanical means ( hydraulic excavator ) / manual means over areas ( exceeding 30 cm in depth, 1.5m in width as well as 10 sum on plan ) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed: 338 random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 ( 1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size ) upto plinth level with cement mortar 1:6 ( 1 cement : 6 sand ) . 339 providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement all work up to plinth level 340 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) 341 plaster on new surface on wall in cement sand mortar 1:4 including racking of joints etc. complete fine finish : 342 20mm thick 343 finishing wall with water proofing cement paint of approved brand and manufacture and or required shadetogive an even shade including all scaffolding: 344 new work ( two or more coats applied @ 3.84 kg / 10 sqm ) . 345 sitc of single stage, water cooled, high speed ( 2880 rpm ) , horizontal, centrifugal, openwell submersible pumps set pre filled with coolent water and fitted with mechanical seal t / c vs t / c, thrust bearing shall be ofcarbon + s.s.the stator body of single phase pumpshall be of ss and rest of all shall be of cast iron. all casting parts should be cathod electro deposition ( ced ) coated and other construction material should be confirming to is : 14220: 2018 . the overall performance of pump shall confirm to bee energy efficiency level of 3 star. valid bee certificate from oem must be submitted for the same. motor should be ie2 class as per iec 60034 2 1: 2007, iec 60034 30: 2008, & is12615:2011, including making connection etc as required complete in all respect. oem shall have submitnabl / cpri / erda accrediatedlab type test certificate before execution. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 346 5.0 hp, 3 ø, ( 14 28 ) mtr, ( 995 500 ) lpm 347 sitc of contactoroem fabricated dol / star delta starter panel with switchgear selection as per type 2 cordinatiom chart andmade out from 1.6 mm thick powder coated crca sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, illuminated on / offpush buttons, ammeter, voltmeter, indicating lamps etc.suitable for following rating motors complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 348 for three phase submersible / mono block pump 349 3.0 hp to 5.0 hp ( dol starter ) 350 part b non bsr items based on market rate 351 sitc ofro water system with filtration stage = particulate filter membrane life enhancer filter sediment filter pre carbon filter ro membrane filter post carbon filter, input power rating 230 v ac , 50 hz, percentage of rejection tds 90% or better having following features ( a ) double purification by ro with ess or latest technology with tds indicator ( b ) .spin welded ro membrane housing to prevent tempering ( c ) . push fit components for leak proof performance ( d ) . fully automatic operation with auto start and auto off ( e ) . ss construction for corrosion free lifespan ( f ) . equally suitable for water from all bore wells, , overhead storage tanks, water tankers and even municipal taps ( g ) ro membrane flushing auto flush @ every start , every stop and every one hourof working for one minute. complete in all respect with following capacity. approved make:eureka forbes, kent, au smith, ion exchange, pentair. 352 purification capacity 50 lph, duty cycle 270 500 liters / day, 353 sitc of dome ip ir cctv cameras: network h.265 2mp ( full hd ) megapixel high frame rate mini dome camera with built in microphone:2mp ir dome camera with metal body and built in mic: 1 / 2.8 progressive scan cmos; resolution: 1920 × 1080@30fps or better; colour: 0.01 lux @ ( f1.2, agc on ) or better, h.265+ compression or better; 120 db true wdr or better; fixed 2.8 / 4mm lens; built in mic; 3d dnr; 40m ir range or better, triple streams; blc, 3d dnr, hlc; line crossing detection, intrusion detection; scene change detection; face detection; anti flicker, heartbeat, mirror, password protection, privacy mask, watermark, ip address filter; onvif ( profile s, profile g ) , isapi; built in micro sd / sdhc / sdxc slot, up to 128 gb or better; operating condition: 30 °c to +60 °c; ip67; 12dc & poe; certificate of compliance: ul, ce / fcc, bis, rohsapproved make: samsung / hikvision / panasonic / infinova / cp plus / dahua / honeywell 354 sitc of ip ir cctv bullet outdoor camera: network h.265 2mp ( full hd ) megapixel high frame rate ir bullet camera ( outdoor ) with metal body, 2mp full frame low light ir bullet camera: 1 / 2.5 progressive scan cmos; resolution: 1920 × 1080 or better; color: 0.002 lux @ ( f1.2, agc on ) or better; slow shutter; fixed 3.6 mm lens; triple streams; 3d dnr; 120db wdr; 50m ir range or better; line crossing detection, intrusion detection, object removal detection, unattended baggage detection, scene change detection; face detection; anti flicker, heartbeat, mirror, password protection, privacy mask, watermark, ip address filter; onvif ( profile s, profile g ) , isapi; roi; support micro sd / sdhc / sdxc card ( 128g ) , local storage and nas ( nfs, smb / cifs ) , anr; operating condition: 30 °c to +60 °c; ip67; 12dc & poe; metal body; built in junction box for cable management; certificate of compliance: ul, ce / fcc, bis / rohs approved make: samsung / hikvision / panasonic / infinova / cp plus / dahua / honeywell 355 sitc of raid 5 supported 32ch nvr with upto 48 tb hdd support 32ch ip inputs; dual os for redundancy; support anr technology;320mbps incoming bandwidth, supports up to 12mp full channel recording; support h.265 compression; 16ch syncronised playback @1080p; support raid 5; n+1 hot spare system; support 3rd party cameras; 4k output; minimum 8 sata hdd slots; each slot should suppport upto 6tb hdd; e sata interface; dual gigabit self adaptive ethernet interface; serial interace; usb interface; alarm in / out;dual power supply ( all cameras and storage nvr should be of same make for the smooth functioning of the system ) . certificate of compliance: ul, ce / fcc, bisapproved make: samsung / hikvision / panasonic / infinova / cp plus / dahua / honeywell 356 sitc of 3.5 6tb surveillance hard disk ( makes: seagate / wd / toshiba ) 357 sitc of workstation latest intel® i5 processor, with 17 led monitor screen intel chipset motherboard, 08 gb ram, 1 tb sata hdd at 7200 rpm, with 4gb gpu type higher end graphic card for h.265 compression technique with dual display ports / dvi / hdmi port, giga lan card, wireless keyboard, wireless optical mouse with original license windows software of approved makes: lenovo, hp, dell. 358 sitc of 55 flat smart screen hd profesional led with remote control and wall mount unit / floor stand complete with making connections etc of approved makes: lg, samsung, panasonic. 359 sitc of 5 kva 1 phase input, 1 phase output advance dsp controlled ups with igbt based rectifier, lcd display, double conversion / digital signal processing ups, with isolationtransformer, with 26ahx x 16 nos smf batteries for min 30 min back up, with ms rack for barreries and required cabling for incoming & outgoing connection of approved makes: numeric, eaton, emerson, apc. 360 supply, installation, testing & commissioning of managed layer 2 intelligent ethernet poe switches providing 08 x 10 / 100 / 1000 fast ethernet poe ports 67w or better and 2 dual purpose uplink ports ( provision for copper / fiber giga connectivity ) all switches & related fiber modules should be of same make & category for seamless integration with each other of approved makes: cisco catalyst series or equivalent in avaya, juniper ) 361 p & f of early streamer emission type lightning arrester on gi mast with air terminal configured as spheroid which is comprised ofseparate electrically isolated 4 panels surrounding an earthed central finial, the terminal shall be tested by cpri for impulse current of 45 ka ( 8 / 20 sec ) with 5 positive & 5 negative impulse, the arrester having following protection radius at level 1 approved makes :lpi ( australia ) , lpsfr ( france ) , sudafix ( uk ) , ef ( switzerland ) , abb 362 30 48 mtr. 363 s & laying of p.v.c. / xlpe insulated & p.v.c. sheathed down conductor of 70 sq.mm single core insulated flexible copper cable confirming to is:1554 p i / is :7098 p i of 1.1 kv withelectrolytic gradecopper made of copper rodsconfirming to is 613 1964, of purity >99.7 %, inner / outer sheath confirming to is:5831 with accessories as required. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810approved makes: polycab, rr, finolex....

Rajasthan State Road Development And Construction Corporation Limited - Rajasthan

36348916 tender for electrification work of iti building at kareda district bhilwara wiring of light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked mms ( is:9537 p iii ) virgin material pvc conduit & itsisi marked ( is:3419 1988 ) accessories, round tiles, 1.2 mm thickhot dipped galvanized modular box with earth terminal, 10a modular switch, modular face plate with grid plate, 3 pin ceiling rose / holder / 3 way connector, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 3 short point ( up to 3 mtr. ) 4 medium point ( up to 6 mtr. ) 5 long point ( up to 10 mtr. ) 6 wiring of twin control light point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) in recessed isi markedmms ( is:9537 p iii ) pvc conduit & its isi marked ( is:3419 1988 ) accessories, round tiles, 2 nos hot dipped galvanized m.s modularbox of 1.2 mm thickwith earth terminal, 2 nos10 a two way modular switch, 3 pin ceiling rose / holder / 3 way connector , modular face plate with grid plate, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 7 long point ( up to 10 mtr. ) 8 wiring of 3 / 5 pin 6 amp. light plug point with 1.5 sq. mm nominal sizefr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked mms ( is:9537 p iii ) pvc conduit & its isi marked ( is:3419 1988 ) accessories, hot dipped galvanizedmodular box of 1.2 mm thick with earth terminal, 10 a modularswitch, 3 / 5 pin 6 a modular socket, modular face plate with grid plate, screws, making connections, testing etc. as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessories refer chapter e 04, e 05 & e 07 for additional technical parameters of product / work refer annexure a attached with this bsr 9 on board 10 short point ( up to 3 mtr. ) 11 medium point ( up to 6 mtr. ) 12 long point ( up to 10 mtr. ) 13 s&f following sizes ( dia. ) of isi marked virgin material mms ( is:9537 p iii ) pvc conduit along withisi marked ( is:3419 1988 ) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. for additional technical parameters of product / work refer annexure a attached with this bsr 14 20 mm 15 25 mm 16 32 mm 17 40 mm 18 50 mm 19 s&f following sizesof isi marked ( is:14927 p ii ) virgin materialupvc trunking along with accessorieslike coupler, inner, outer, elbow, square box, tee, end cap etc. on surfacewithscrews, expansionfastenersas required. for additional technical parameters of product / work refer annexure a attached with this bsr 20 100 mm x 50 mm 21 150 mm x 50 mm 22 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from99.90 % purity copper, class 5 stranding in acc. to is:8130 / iec 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation pvc type a / c / d , flame retardant as per is 10810 53, better amperage rating as per is:3961 part 5, in existingsurface or recessed pvc / ms conduit / casing capping making connections with copper lugs of suitable size, ferrules, testing etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of product / work refer annexure a attached with this bsr 23 1 x 1.5 sq.mm 24 2 x 1.5 sq.mm 25 3x 1.5 sq.mm 26 1x 2.5 sq.mm 27 2 x 2.5 sq. mm. + 1x1.5sqmm 28 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 29 2 x 6.0 sq. mm. + 1 x 4.0 sq. mm. 30 2 x 6.0 sq.mm 31 2 x 4.0 sq.mm 32 4 x 10.0 sq.mm 33 4 x 16.0 sq.mm 34 supplying and drawing pe insulated & pvc sheathed unarmoured telephone cable with 0.5 mm dia. solid annealed electrolytic grade bare copper conductor as per is: 8130 / 84 &confirming to tec specification gr / wir / 06 03 march 2002in existingsurface or recessed conduit / casing capping. including ferruling on each pair for identification etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 35 2 pair 36 supply and laying of pe insulated jelly filledarmouredtelephone cable. with 0.6 mm thick solid annealed bare copper conductor and confirming to tec specificationsconfirming. to dot gr / cug 01 / aug.2003 in existing pipe / open trench / cable tray / on surface including making necessary connection, testing etc. as required of size. for additional technical parameters of product / work refer annexure a attached with this bsr 37 10 pair 38 50 pair 39 supplying and drawing coaxial cable 75 ohm impedance with foam pe insulated solid bare copper inner conductor, and ist outer conductor of bonded alum. tape and second outer conductor ofalum. alloy braidin existingsurface or recessed conduit / casing capping including making connections as required. for additional technical parameters of product / work refer annexure a attached with this bsr 40 rg 6 41 p / laying isi marked p.v.c. insulated submersible cable confirming to ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from99.90 % purity copper, stranding in acc. to is:8130 / iec 60228 forlower watt loss , oxygen freefor less chances of oxidization, insulation pvc type a / c / d , flame retardant as per is 10810 53, better amperage rating as per is:3961 part 5, existing pipe / open trench / cable tray / on surface including making connection etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 42 2.5 sq.mm 3 core flat / round 43 4.0 sq.mm 3 core flat / round 44 6.0 sq.mm 3 core flat / round 45 p & f paper phenolic resin bondedlaminates confirming to is : 2036 1995 for boxes / frames including making holes for switches etc, with brass screws, washers / zinc platednut and bolts as required. for additional technical parameters of product / work refer annexure a attached with this bsr 46 3.0 mm thick 47 4.8 mm thick 48 6.4 mm thick 49 p & f 1.2mm thickm.s. recessed fan box, hexagonal / round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mmlength extended on each side . all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr 50 p & f krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted, including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 51 10 pairs 52 50 pairs 53 supplying and fixing of power plug point with modular accessories as per pwd specification for electrical works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal / connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofisi marked modular 16 amp. switch ( is :3854 ) and 6 / 16 amp. socket outlet ( is:1293 ) making connection , testing , etc. as required. for specification ofwiring accessories refer chaptere 07related item & for additional technical parameters of product / work refer annexure a attached with this bsr 54 p&f metal clad / plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain / bakelite base in recessed / surface mounting heavy duty enclosure made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3. powder painted ( without mcb ) including making connections, testing etc.as required.for additional technical parameters of product / work refer annexure a attached with this bsr 55 20 amp, 3 pin + scrapping earth, 4 module 56 32 amp, 5 pin + scrapping earth, 8 module 57 making of hole in wall ( brick / stone ) of required and placing np 2 rcc pipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 58 up to 457 mm size 59 providing & fixing ofextra down rod of 15 mm dia . erw ( electrical resistance welded ) of 1.6mm nominal thick medium duty steelpipe including cutting, threading, drilling, fixing quarter pin etc as reqd.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 60 providing & fixing of single / multi tone electronic call bell as per pwd specification for electrical works, including making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 61 providing & fixing of modular type switch / bell push duly isi marked ( is :3854 ) with cm / l no. printed and made out of unbreakable and fire retardant vergin uv stabilized polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , minimum width ofswitch toggle ( push part ) should not less then 20mm, includingall as per pre approved by engineer in charge, making connections, testing etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 62 10 a one way switch 63 32 amp. 2 moduleswitch with ledindicator 64 providing & fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , includingall as per pre approved by engineer in charge, making connections, testing etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr 65 6 a3 / 5 pin shuttered socket 66 25 amp. 2 module socket 67 providing & fixing of modular type 120 w step fan regulator duly isi marked ( is 11037:1984 ) with cm / l no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , includingall as per pre approved by engineer in charge, making connections, testing etc. as required.for additional technical parameters of product / work refer annexure a attached with this bsr 68 5 step fan regulator 2 module 360 dgree rotating 69 providing & fixing of following modular accessories as per pwd specification for electrical works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , includingall as per pre approved by engineer in charge, making connections, testing etc. as required.for additional technical parameters of product / work refer annexure a attached with this bsr 70 t.v. coaxial socket 71 rj 11 telephone jack double line 72 blanking plate 73 modular mcb 6 a to 32 adp 74 providing & fixing offollowing size mounting grid plates with cover plates made from fire retardent uv established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 75 1 / 2 module 76 8 module 77 providing & fixing ofwiring accessories oem fabricated following size gi box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess / surface suitable for modular accessories as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 78 1 2 module 79 6 / 8 module 80 providing & fixing of ip20 smd mid power led batten type integrated light fixture made from powder coated extruded aluminiumhousing with in built driver, system lumen efficacy = 110 lm / watt output, internal surge protection of 2.5 kv with short & open circuit protection , thd < 10% , p. f.=0.95, cri >80 , life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing on housing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 81 1170mm ( + / 10% ) led batten with min. lumen output 2200 lm 82 570mm ( + / 10% ) batten with min. lumen output 1000 lm 83 providing & fixing of ip 20 led recessed / surface mounted, round / sqauresmd mid power led downlight with power coated die cast aluminum housingwith uv stabilized non yellowish diffuser withbis complience 2.5 kv surge protected isolated driver, with short & open circuit protection, having efficiency > 85% . system lumen efficacy of = 110 lm / watt, thd < 10 % , pf.=0.95, cri >80, life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. 84 oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 85 surface mounting ( with extruded alumn. housing ) 86 minimum lumen output 1300 lm 87 minimum lumen output 1950 lm 88 providing & fixing of ip20, 2x2 led surface / recessedmounting mid power smd type led light fixture not less than 50mm housing depth made from crca sheet steel housing, high purity / transmisivity uv stabilized non yellowish diffuser for uniform light distribution. high efficiency with 4 kv internal / external surge protection bis certified isolated driver having efficiency > 85% , with short & open circuit protection ( integral with light fixture ) . system lumen efficacy of = 120 lm / watt , thd < 10 % , p.f.=0.95, cri >80 , life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. 89 oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 90 surface moutning 91 minimum lumen output 4200 lm 92 providing & fixing of ip65 ik08 rated integrated smd mid power led bulk head type light fixture made from pressure die cast al housing suitable with integral driver, system lumen efficacy =100 lm / watt output , thd < 10% , p.f.=0.95, cri >80 , life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. surge protection 4 kv. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 & lm80 ) certificate / report from oem shall be submitted.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 93 minimum lumen output 1000 lm 94 providing & fixing of 400 mm sweepbldc technology oscillating type wall mounting / pedestal typefans with three speed, on andoff position, double wall bearing withfront and back 120 or moreribs guard; three no.blades, noise level should be <= 75 db, including fixing with anchor bolts, making connection testing etc. as required. ( with remote ) all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 95 wall mounting type with service value 2.0 cmm / w, min. air delivery 71 cmm 96 providing & fixing ofbeestar rated copper wounded double ball bearing capacitor start, aluminium body & metallicblade ceilingfanconforming to all the performance requirements laid down in is 374:2019 including all amendments, as applicable ; & carry bis licensing ( i.e. isi marking ) with down rod up to 80 cm with secondary support safety cable ( steel rope ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 97 1200 mm sweep bee 1 star rated ( service value >=4.0 to < 4.5 ) 98 providing & fixing ofof double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor , making connections, testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 99 300 mm sweep 100 providing & fixing of heavy duty capacitor start, copper wounddouble ball bearing900 / 1400 rpm single phaseexhaustfan conforming to is:2312 isi marked in existing opening including making connections testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 101 300 mm sweep ( 900 / 1400 rpm ) 102 380 mm sweep ( 900 / 1400 rpm ) 103 providing & fixing ofof ventilating fans capacitor start, copper wounded, single phase with pvc impeller, abs body, automatic openable louver shutter in existing opening including making connection, testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 104 150 mm sweep 105 250 mm sweep 106 p & f of wall cowl with bird screen suitable for outside wall of exhaust fan openingof following size and made out from 24 swg gi sheet as per instructions of engineer in chargeincluding fixing with suitable fasteners etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 107 suitable for 300 mm sweep exhaust fan 108 suitable for 380 mm sweep exhaust fan 109 providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket / pole. fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with uv stabilized pc ( uv stablization report submitted for uv cover ) / toughened glass coverand secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm / wt and potted driver& has a unique bis r number withinput voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driverefficiency >85%, thd ( i ) <10%humidity 10% to 90% rh working temp 5c to 45c .driver current <750ma. the luminaireshall be bis certified and trade mark certified. life expectancyequal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min = 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs.manufactures word mark / name engraved / embossing on die cast housing to allow traceability / authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities forled fixtures. ( lm79 / lm80 ) certificate / report with liable warranty of product / accessories from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 110 led street light fixture with minimum lumen output 11225 lm 111 supply and erection ofgalvanized iron pole with galvanizing done in single dipping ( average coating thickness minimum 65 microns ) continuously tapered poles having octagonal / circular cross sections designed to withstand the maximum wind speed as per is 875, the pole shaft shall be made from sheet steel ( ht steel conforming to grade s355jo ) and confirming to bsen 10025 and shall be continuously tapered with single longitudinal welding. there shall not be any circumferential welding. the welding of pole shaft shall be done by submerged arc welding ( saw ) process. pole shafts shall be provided with the rigid flange plate of suitable thickness ( fe 410 conforming to is 226 / is 2062 ) with provision for fixing 4 no. foundation bolts, this base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.the octagonal poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the base plate with bakelite sheet having 6a sp mcb and 16 sqmm stud type connector ( 4 nos ) inside the pole at door opening for cable connection of following length and dimension as per table p 01 with base plate and foundation bolt on the existing cement concrete foundation.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 112 poles with octagonal cross section 113 7 mtr. 114 supply and fixing of pole oem fabricated hot dipped galvanised m.s. overhang ( 48.3 x 3.25 mm ) with cap ( 400 x 88.9 / 114.3 x 3.25 mm ) over the existing poles. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 115 single arm overhang 116 providing and laying rcc foundation for octagonal / conical street light poles, high mast poles as per drawing attach at tablep 4with following procedure& all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 117 a ) excavation of pit for foundation size upto required depth from ground level 118 b ) dressing of pit and dry stone pitching 200 mm thick including supply of stones and preparing surface complete. 119 c ) providing and laying in position cement concrete of m 10 grade of 75 mm thickness 120 d ) reinforcement for r.c.c. work with tmt bars including straightening, cutting, bending, placing in position and binding all complete. 121 e ) centring and shuttering including strutting , propping etc. and removal of form work for footing and pedestal 122 f ) providing & fixing of 2 no. required sizeplb hdpe pipe& foundation bolt with template as per oem recommendations. 123 g ) providing and layingreinforce cement concrete of m 25 grade in footing and pedestal including curing the foundation for 7 days. 124 h ) providing and fixing nosing angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. lugs on each face. 125 pole foundation for octagonal pole from 7 mtr. to 9 mtr. 126 providing & fixing of ik08ip65 protected top / bottom mounted led post top luminarie made of single piece constructionpowder coated die cast alluminium housing with uv stabalized clear / frosted polycarbonate diffuser andaluminium anodised with sand blast reflector. the system level luminous efficacy =100 lumen / w. smd leds is to be used, system cri>70, cct: 3000 / 4000 / 6500 k. the integral electronic driver must be potted & has a unique bis r number must be potted & has a unique bis r number constant current and internal / external surge protection device of min. 4kv ( l n ) and efficiency > 85%, pf>0.9, thd<10% and input voltage range of 140 270v ac at 50hz. system life of 50000 burning hours with 70% of initial lumens maintained . driver current <750ma.fixture must be in compliance with bis standards and trade mark certificate complete in all respect.oem must have its own in house nabl lab setup for all testing facilities forled fixtures. ( lm79 / lm80 ) certificate / report with liable warranty of product / accessories from oem shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 127 minimum lumen output 4500 lm post top luminarie 128 providing & fixing of street light bracket made out from following size of b class , medium class g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with heavy duty pole clamp, saddles suitable fastners etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 129 40 mm dia. 130 supply , installation, testing and comissioning of is:1475 marked self contained drinking water cooler withhermeticallysealed compressor, non cfc refrigerent suitable for operation on 230v / 1ph / 50hz ac supply, full stainless steel ( ss304 ) body ( 0.8 mm thick ) and tank ( 0.5 mm thick ) , stainless steel water tray, minimum two nosbrass chrome plated faucets and suitable drainage system complete in all respect with requiredheight ms fabricated and painted angle iron frame ( cost of frame to be paid extra ) complete in all respect of the following capacity.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 131 cooling capacity 150 ltr. / hr. and storage capacity 150 ltrs 132 providing and laying non pressure np 3 classr.c.c. pipes including collars / spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) etc. as required. ( excavation of earth& back filling with compaction is to be paid extra ) . all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 133 200 mm dia. 134 labour charges for excavating trenches of required width for pipes dressing of sides, ramming of bottoms, depth up to 1.5 mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 mtr.: 135 all kind of soils 136 sitc of wall type following zone ( each zoneaccessing minimum 20 units ( detectors / devices ) ) conventional type microprocessor based with lcd display en / lpcb / ul listed / approved main control panel fabricated from 16 swg crca sheet steel sealed maintenance free ( smf ) batteries of min2x7ah of 12 v or as required.including the cost of all accessories, etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 137 4 zone 138 sitcof en / lpcb / ul listed / approved conventional type manual call point resettable complete with glass, hammer and chain etc.including the cost of all accessories etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 139 sitc of en / lpcb / ul listed / approved conventional type hooter cum strobe including the cost of all accessories, etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 140 supply & fixing of water + afff 6%mechanical foam typefire extinguisher ( stored pressure type ) conforming to is:15683:2018 , powder coated internal & external surface deep drawn cylinder body of mild steel cr2 grade conforming to is: 513, squeeze grip forged brass release valve with inbuilt safety release device, diaphragm type, 0 to 25 bar range pressure gauge, 450 mm long epdm discharge tube, qr code for product traceability including fixing on wall with suitable anchor fasteners as required of following capacity. test certificates of all the parameters along with hydro test & burst test ( for cylinder body ) certificatefrom oem / external nabl accrediated lab is to be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 141 capacity 6 ltrs. 142 supply & fixing of co2 type fire extinguisher conforming to is:15683:2018, charged with co2 gas ( purity 99.7% conforming to is 15222 ) , powder coated internal & external surface manganese steel isi marked as per is 7285 cylinder body , wheel type forged brass release valve isi marked as per is 3224 with inbuilt safety release device ( ( fusible plug and rupture disc type ) , 1.0 mtr. metal wire braided hose having minimum bursting pressure of 140 kgf / cm2, horn with metallic thread connection, qr code for product traceability, including fixing on wall with suitable anchor fasteners as required of following capacity. test certificates of all the parameters along with hydro test & burst test ( for cylinder body ) certificatefrom oem / external nabl accrediated lab is to be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 143 capacity 4.5 kg. 144 supply & fixing of dry powder agent ( as per is 4308:2019 ) , abc typefire extinguisher ( stored pressure type ) conforming to is:15683:2018 , powder coated internal & external surface deep drawn cylinder body of mild steel cr2 grade conforming to is: 513, squeeze grip forged brass release valve with inbuilt safety release device, diaphragm type, 0 to 28 bar range pressure gauge, 450 mm long epdm discharge tube, qr code for product traceability including fixing on wall with suitable anchor fasteners as required of following capacity. test certificates of all the parameters along with hydro test & burst test ( for cylinder body ) certificatefrom oem / external nabl accrediated lab is to be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 145 4 kg 146 supply , installation, testing and comissioning ofinverter type air cooled hi wall split type air conditioners with latest star rating system as per bee amended upto date complete with indoor unit ( idu ) , out door unit ( odu ) , surface / concealed copper refrigerant piping with insulation ( closed cell elastomeric nitrile rubber tubular pipe section ) upto 3 mtr ( idu to odu ) , copper power cable upto 3.5 mtr ( idu to odu ) , r 32 / r 410 green refrigerant, wireless remote control, suitable for working between 230v + / 10% with low & high voltage cutoff and50 hz , single phaseacsupply capable of performing cooling, dehumidification, air circulation of following capacity with scroll / rotary compressor. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 147 1.5 tr iseer not less then 4.6 148 2.0 tr iseer not less then 4.6 149 providing & fixing of is : 4985 2000 class 4 ( 10 kgf / sqcm ) upvc drain water piping withfittings ( is:7834 & 10kgf / sqcm ) like elbow, socket, tee, solvent cement jointing, support with ms hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following nominal sizes. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 150 25 mm 151 supply, fixing and testing of following capacity iso certified company made wall mounted stabilizer having output voltage variation from 200 v to 250 v ( + / 5% ) with input voltage variation from 170 v to 260 v, time delay facility from 2 to 4 minute and high cutoff at 270 v with providing of 16 amp / 20 amp industrialplug top making connection etc complete in all respect.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 152 4 kva 153 5 kva 154 making hole in stone masonary / rcc wall / rcc slab with core cutter for accomodating refrigerant pipe / drain pipe / ms pipe / cables etc of following dia 155 50 mm dia per running inch length 156 supply & fixing ms powder coated stand suitable for 1.0 / 1.5 / 2.0 tr outdoor type of split ac.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 157 sitc of interconnecting refrigerantcopper pipe forsplit / ductable / casseette ac of dhe grade c12200 astm b68, b75, chemical composition of copper % 99.0 min and phosphorus % 0.015 to 0.040 . for annealed copper tube : tensile strength = 210 mpa wih elongation % = 40 min . ink markbrand printing on hard tubes should be present. piping between each set of indoor & outdoor units of different sizesas per oem requirement & specifications including class o nitrile rubber sleeves, chase cutting, supports, making good the same with sand cement plaster etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 158 supplying and drawing flexible / stranded bare copper conductor, pvc / xlpe insulated, overall aluminium mylar tape shielded atc drain wire and outer pvc sheathed industrial instrumentation ( shielded ) cables voltage grade 300 / 500 v as per bs / en 50288 7 in existingsurface or recessed pvc / ms conduit / casing capping / cable tray / open duct making connections, testing etc. as required. oem must have its own in house nabl lab setup for all testing facilities for cables. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 159 un armoured 160 4 core x 2.5 sq.mm 161 providing & fixing of 240 / 415 v ac mcb with positive isolation of 10 ka breaking capacity ( b / c / d tripping characteristic as per type of load andsite requirement ) 4 kv impulse withstand voltage, isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , ip 20 contact protection and fitted inexisting distribution board / sheets, minimum electrical operation 20, 000 upto 20 a rating and 10, 000 upto 63 a, 5000 for 80 a & above ratingincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 162 single pole mcb ( with b / c curve tripping characteristics ) 163 0.5 a to 5 a rating 164 6 a to 32 a rating 165 double pole mcb ( with b / c curve tripping characteristics ) 166 50 / 63 a rating 167 triple pole mcb ( with d curve tripping characteristics ) 168 6 a to 32 a rating 169 50 / 63 a rating 170 four pole mcb ( with b / c curve tripping characteristics ) 171 50 / 63 a rating 172 40 a rating 173 providing & fixing of 240 / 415 v residual current circuit breaker ( rccb ) conforming to ( is:12640 1 ) / iec 61008 1 , rated 4 kv impulse withstand voltage truly current operated and shall operate on cbct mechanisum, provision for pad lock, min. operation 10, 000 upto 63 a rating and5000 for 100 aratingand minimum phase termination capacity of 35 sq.mm. rigid wire, ip 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 174 two pole 100 / 300ma sensitivity 175 40 a rating 176 63 a rating 177 providing & fixing of recessed / surface mounting heavy duty horizontal type double door ( metal / glazed ) distribution board with metal end box made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3, powder painted complete with reversible door ( for double door db only ) 100 amp. insulated copper bus bar / shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar, masking sheet, making internal db terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 178 glazed door ( single phase ) ik 09 and ip 43 with metal end box 179 12 way ( 12+2 ) 180 metal door ( three phase ) per phase isolation, horizontal ik 09 and ip 43 with metal end box 181 4way ( incomer 8, sub incomer2+2+2 ) 182 6way ( incomer 8, sub incomer2+2+2 ) 183 8way ( incomer 8, sub incomer2+2+2 ) 184 12 way ( incomer 8, sub incomer2+2+2 ) 185 providing & fixing of recessed / surface mounting heavy duty vertical tpn distribution board with metal end box with provision of incomer suitable for 3 / 4 pole mccb and sp / tp mcb as outgoing , made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is 8623 1 & 3 / iec 61439 1 & 3. powder painted with reversible door ( for double door db only ) complete with insulated 160 ( upto 160 a incomer ) / 250 amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar, masking sheet, making internal db terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab type test reports& all as per pre approved by engineer in charge.for additional technical parameters of product / work refer annexure a attached with this bsr 186 double door ip 43 & ik 09 with provision of incomer mccb 100 / 125 a rating with metal end box 187 4 way 188 6 way 189 8 way 190 12 way 191 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed arrmouredaluminiumcable confirming to is:1554 p i / is :7098 p i of 1.1 kv withh4 grade electrolyticaluminium conductor confirming to is 8130 of purity >99.6 %, round / flat strip armouring of cables, inner / outer sheath confirming to is:5831in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench / cable tray ( with cable tie ) includingtesting etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810.for additional technical parameters of product / work refer annexure a attached with this bsr 192 6.0 sq. mm 193 4 core 194 10.0 sq. mm 195 4 core 196 16.0 sq. mm 197 4 core 198 35.0 sq. mm 199 3.5 core 200 70.0 sq. mm 201 3.5 core 202 95.0 sq. mm 203 3.5 core 204 185.0 sq. mm 205 3.5 core 206 add extra for laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv gradedirect in ground including excavation of trench of size 75 cm ( depth ) x 35 cm ( width ) , with procedure as per followingpoints: ( a ) make a river sand bed of height 125 mm along the trench, ( b ) lay the cable in the middle of the trench, ( c ) provide river sand bed of height 125 mm on top of the cable, ( d ) lay the protective common burnt clay f.p.s. bricks of class designation 75 / sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( approx. 9 no. bricks per mtr. ) , ( e ) backfill the excavated soil leaving 300 mm from the ground level, ( f ) lay the cable warning tape and again back fill the remaining portion of the trench upto the ground level and compacting the earth 207 add extra for laying of one number additional pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv gradedirect in ground in the same trench in one tier horizontal formation including excavation of trench of size additional 20 cm in width, with procedure as per following points : ( a ) make a river sand bed of height 125 mm along the trench, ( b ) lay another cable in middle of trench in such manner that spacing between another cable is 20 cm., ( c ) provide river sand bed of height 125 mm on top of the cable. ( d ) lay the protective common burnt clay f.p.s. bricks of class designation 75 / sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( approx. 9 no. bricks per mtr. ) , ( e ) backfill the excavated soil leaving 300 mm from the ground level, ( f ) lay the cable warning tape and again back fill the remaining portion of the trench upto the ground level and compacting the earth. 208 supplying and making one end termination with nickel plated heavy duty brass single compression gland ( as per is 12943 1990 ) ) sibg type consisting of check nut, gland body, metal washer ( 3 nos. ) , outer seal rubber ring, compression nut, heavy duty aluminium lugs ( as per is 8309 1993 ) duly crimped with crimping tool, pvc tape as peris 8337 1976offollowing size ofpvc insulated & pvc sheathed / xlpe aluminium conductor cable of 1100 volt grade as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 209 3.5 x 185.0 sq.mm 210 3.5 x 95.0 sq.mm 211 3.5 x 70.0 sq.mm 212 3.5 x 35.0 sq.mm 213 4 x 16.0 sq.mm 214 4 x 10.0 sq.mm 215 4 x 6.0 sq.mm 216 supply, fabricating & installing following sizes of perforated hot dipped galvanized iron cable tray ( galvanized thickness not less then 50 microns ) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees, cross members and other accessories as required and duly suspended from the ceiling with gi suspenders including gi bolts & nuts , fastners, supports etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 217 150mm x 50mm x 1.6mm 218 p / l of double wall corrugated hdpe pipe confirming to is : 16205 p 24, stiffness class750 n, externally corrugated and having smooth surface insidewith hdpe coupler, elbow, teeat required depth below the ground for laying cable of followingnominal outer dia.mfr test reportfrom nabl accrediated is to be submitted. ( excavation of earth& back filling with compaction is to be paid extra ) all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 219 50 mm 220 110 mm 221 plate earthing as per is:3043 withcopper earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying3 mtr. below the ground level with 20mm dia. g.i. b class watering pipe , including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke / charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 222 supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % copperthickness ( 250 microns ) andconfirming toul 467, is / iec 62561 2of following size and length and as per point mentioned ( a ) , ( b ) , [ c ) , ( d ) , ( e ) below : 223 ( a ) bore a hole of dia. 100 mm of required length, place the rod in the centre of hole 224 ( b ) filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, cpri / erdatested with rms capacity of minimum 30 ka for withstanding 1 second .to ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. the compound shall be tested form nabl acredeated labfor lowresistivity ( less than 0.12 ohm meter ) & high conductivity in nature with carbon as a major contentas per referance of is 3043 1987, ieee 80 2013 ( clause 14.5d ) , ieee 837 & ier 1956 with latest amendemnts 225 © connect the rod with copper strip / conductor / wire with suitable clamp made from tinned copper and ss 304 bolt 226 ( d ) place heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height250 to 300 mm. 227 ( d ) testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 228 ( e ) test certificatesfor confirming above standards from oem is mandatory. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 229 25 mm thick and 3 mtr. long 230 supply & laying following size earth stripin horizontal or vertical run in surface by means of earth strip dmc insulatorincluding riveting / soldering / welding, jointing shall be done by overlapping and with 2 set of brass ( for cu strip ) / gi ( for gi strip ) nut bolt & spring washer spaced at 50cm making connection etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 231 25mm x 3mm g.i. ( hot dipped ) strip 232 50mm x 6mm g.i. ( hot dipped ) strip 233 40mm x 6mm copper strip 234 supply & laying following size b class , g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor / strip / cable in ground / surface / recess as required.all as per pre approved by engineer in charge. ( earth excavation will be paid extra ) all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annex ure a attached with this bsr . 235 50 mm dia. 236 65 mm dia. 237 80 mm dia. 238 100 mm dia. 239 150 mm dia. 240 supply & laying following size earth wire in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection with gi / cu purity purity >95%thimble etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 241 8 swg g.i. ( hot dipped ) wire 242 supply, drawing and testing of 4 pair, 23 awg solid bare copper wire insulated with pvc, utp ( unshielded twisted pair ) , category 6, class e, 100 ohm impedance, indoor cable as per latest ammendments of ansi / tia / eia 568 , the copper conductors should be balanced twisted in pairs, seperated by a cross member fluted pair divider & protected bypvc jacket. certified performance in a 4 connector configuration upto 100 mtrs channel requirements & transmission frequencies up to 250 mhz. in existing ms / pvc conduits / casing capping including making connections to information outlets and patch panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 243 supply and installation of unsheilded / 360 degree sheilded information outlets made of high impact plastic body with abs, fr grade halogen free material with provision for protection against dust in jack, suitable for cat 6 / 6a application complying to latest ammendments, according. to cat. 6 / 6a channel, it should support channel as well as components requirements of cat.6 / 6a standards at frequencies of up to 250 to 500 mhz. cat 6 / 6a unshielded / shielded jack should be suitable to terminate 4 pair, 23 / 24 awg solid / stranded wire diameters, using 100 ohm unshielded / shielded balance twisted pair cable, the jack should have tooless / impact termination on reliable copper tin plated insulation displacement contact, with easy lock mechanism, it supports iec 60603 7 4 and complied with ansi / tia / eia 568 c.2 standard. jack should be rj11, rj12 & rj45 compatible. should support ethernet 1.2 gb / s atm, digital video and broadband / baseband analog video, voice over internet protocal ( voip ) specifications in existing modular / ms boxes along with necessory connections as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 244 cat 6, un sheilded information outlet 245 supply & fixing of square faceplate for flush / surface mount information outlets single / dual or quad aperture , material should bepc+abs body, suitable for rj45 unshielded / shielded connection modules. should match with i. o. oem. dimensions should be 86mm x 86mm as required complete in all respect.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 246 single aperture 247 supply, installation, testing and comissioning of rack mounted 19 1u, cat6 24 port loaded, 1.5 1.6 mm crs chasis, powder coated, sheet steel, made of plastic ( abs ) , modular patch panelswith rear cable management system and mounting hardware to mount the patch panel. should have port identification numbers printed / engraved on front of the panel. etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 248 modular patch panel loaded with cat 6 i / o 249 supply , installation and testing of 4 pair, 100 ohm impedance, cat 6 / 6a / class e / ea patch cords should be constructed of minimum 23 / 24 awg, stranded bare copper cable with frpvc / lszh jacket, with an enhanced performance by factory moulded rj45 connectors with strain relief boots as per ansi / tia / eia 568 c.2 suitable for cat 6 / 6a application complying to latest ammendments category 6 / 6a standards, according. to tia568c.2, iso / iec 11801, en 50173, iec 60603 7 51, en 60603 7, ieee 802.3an minimum requirement for 1g base t to 10g base t performance. patch cords shall be straight thru cable compatible with both t568 a and t568 b wiring schemes, should support ieee 802.3af / ieee 802.3at for poe applications, minimum 750 to 1000 mating cycles in plug contacts for long durability, should support ethernet 10gbase t, 1.2 gb / s atm, token ring 4 / 16, digital video and broadband / baseband analog video, voice over internet protocal ( voip ) .all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 250 cat 6, u / utp ( unscreened / un sheilded twisted pair ) patch cord 251 1 mtr 252 2 mtr 253 supply & installation of ip 20 & ik 08 , ul listedwall mounted double section communication enclosure ( rack ) made from powder coated ( 60 to 80 micron ) crca sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door, vertical mounting rail 1.6 mm with umarking , with all round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. accessories like: 1 no of 19 1u horizontal cable manager, 1 no of 90 cfm 230v ac fan with 1 mts long cable, mounting hardware , 1 no of 19 1u, mountable socket strips with 5 nos of 5a universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with suitable anchor fastneretc as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 254 15 u rack with width 600 mm & depth 400 mm + 100 mm 255 supply & installation of ip 20 & ik 08 , ul listed communication enclosure ( rack ) made from powder coated ( 60 to 80 micron ) crca sheet, vertical mounting rail 1.6 mm with umarking, front sturdy sheet steel frame folded from one piece and welded with 5mm toughened glass door, with all round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, set of 75 mm height 4 castors, 2 of which have brakes, accessories like: 5 nos of 19 1u horizontal cable manager, 2 nos of vertical cable managers, 1 no. keyboard tray, 4 nos of 90 cfm 230v ac fan with 1 mts long cable, mounting hardware , 2 no of 19 1u, mountable socket strips with 6 nos of 5a universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 256 27 u rack with width 600 mm &depth 800 mm 257 supply , installation, testing and comissioning ofmanaged layer 2 intelligent 10 / 100 ethernet switch providing 24 x 10 / 100 / 1000 mbps giga ethernet ports / with min 2 sfp giga ports ( provision for fiber giga connectivity ) with related lan base software including making connections etc as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 258 providing & laying xlpe insulated three core armouredaluminiumcable for working voltage 11 k.v. ( e ) confirming is :7098 p 2withh4 grade electrolyticaluminium conductor confirming to is: 8130 class 2 of purity >99.6 %, insulation screening: extruded semiconducting compound followed by helically wrapped copper tape, round / flat strip armouring of cables , inner / outer sheath pvc type st 2 confirming to is:5831in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench / cable tray includingtesting etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810 all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 259 3 core 185.0 sq.mm 260 add extra for laying of one number xlpe power cable of 11 / 33 kv ( earthed ) voltage gradedirect in ground including excavation of trench of size 120 cm ( depth ) x 35 cm ( width ) , with procedure as per followingpoints: ( a ) make a river sand bed of height 125 mm along the trench, ( b ) lay the cable in the middle of the trench, ( c ) provide river sand bed of height 125 mm on top of the cable. ( d ) lay the protective common burnt clay f.p.s. bricks of class designation 75 / sand stone slabs of 50 mm thicknessand 225 mm wide just above the sand bed vertically across the cable ( approx. 9 no. bricks per mtr. ) , ( e ) backfill the excavated soil leaving 300 mm from the ground level, ( f ) lay the cable warning tape and again back fill the remaining portion of the trench upto the ground level and compacting the earth 261 providing & making heat shrinkable type indoor / outdoor / straight through terminations / joint kitsuitable for11 kv / 33 kv ( earthed ) cable with required components, prepration of cable ends. type test report should be as per is13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streightthrough joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. crosslinking shall be done out side factory with e beam / peroxide technology. extrusion process shall be in house oem within same vicinity. includingtesting etc. as required of following sizes. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 262 11 kv end termination kit indoor type 263 3 core 120 / 150 / 185 sq.mm 264 11 kv end termination kit outdoor type 265 3 core 120 / 150 / 185 sq.mm 266 providing & fixing of iso certified company made on load change over switch, front handle operated, four pole 415 v as per pwd specificationfor electrical works conforming to is / lec 60947 3 : 1999 including connections , testing etc. as required .in the following rating.appropriate type test certificate / oem test report shall be submitted .all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 267 open execution type 268 200 a 269 sitc of ip 42 and general construction confirming to is:8623 : 1993, wall / free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andother parameters requiredas per point ( a ) , ( b ) , ( c ) , ( d ) , ( e ) , ( f ) , ( g ) , ( h ) as below: 270 ( a ) thickness of crca sheet shallbe 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 271 ( b ) complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel.the panel having pe foam / neoprene rubber gasket of not less than 3mm thickness , required hardware , concealed hinged door with key type locking arrangement for equipment / switchgear earthed with 2.5 sq.mm braided copper wire. 272 [ c ) interconnection between bus bar and switchgears / cable shall be rigidly supported and made out by flexible copper wires ( up to 63 amp ) and by solid bus bar ( >63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only.all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgearis to be paid extra ) 273 ( d ) wiring between components within switchgear and incoming / outgoing cableshall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 274 ( e ) all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be ‘point to point’ ( no wire splitting or tee connections ) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 275 ( f ) floor mounted panel shall be mounted on base frame of ismcchannel size 100 x 50 x 5 mm ( to be paid extra ) 276 ( g ) tests: the insulation resistance ( with 1000 v megger ) and high voltage power frequency test ( by applying a voltage of 2.5kv for one minute ) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. the insulation resistance shall not be less than three megaohm. ct secondary current injection test shall also be carried out. 277 ( h ) only outer surface area on all sides shall be measured & panel to be fabricated only from cpri approved fabricator only ( cpri test certificates to be submitted ) all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 278 supplying and fixing of aluminium ( iec 60105 iso 209 1, 2 ) / copper ( iec 60028 ) bus bar by means of smc / dmc type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 279 electrolytic grade aluminium bus bar 6010 grade 280 providing & fixing of is: 13875 & iec :61326 confirming led digital type ( up to 500 ) v range volt meter / direct ammeter / ct oertated ammeter / frequency meter / kwh meter / multi function meter / power analyzer of class 1 accuracyas per is : 1248 of size 96mm x 96 mm including making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 281 threephase amp+hz+pf+kw+kva+kvar+t.energy+thd i, thd v & run hrs 282 providing & fixing of bis approvedcurrent transformeras per pwd specification for electrical works , isi marked as peris 2705 1992 / conforming to iec 60044 1, with secondary terminalof ct shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredcurrent transformer ring type tape wound / resin cast wound as per is 16227 with, accuracy cl, ct ratio and burden as specified. isf<=5, cu cross section of secondary wire 1.5sqmm ( minimum ) , including all necessary support in existing panel including connection etc. as required . all as per pre approved by engineer in charge.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 283 ring type tape wound ct 284 c t class 1, ratio 200 / 5 to 300 / 5, burden 10 va 285 c t class 1, ratio 400 / 5 to 1200 / 5, burden 15 va 286 providing & fixing ofcam operated rotary ( auto / manual ) switches on existing panel with 2 way and off position using high grade engineering materialto international standards with cam assemblyinsulation of glass filled polyamide with high tracking index. for reliable and stable electrical and mechanical endurance double butt contacts with silver bi metal on copper should provided . contact assembly is of operating temp range 25 degree c to 55 degree c, frequency upto 10 khz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles / hour and electrically 10, 000 operations at 100% rated duty for 100 cycles / hour including making connection etc.as required . all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 287 32 amp 288 providing & fixing of110 / 220 v, unibody led indicatinglamp iec 60947with integral circuit, ip 65 above panel &ip 20 terminal block, approx. body dia for panel not less then 20 mm, length min. 50mm, front led cover dia min.29 mm, contact material phospher bronze for led, pcb contacts shall be ofbrass ( tin plated ) , impulsedielectric tested for 2.5 kv, rated insulation resistance shall be 100 m ohm at 500vdcincluding connection etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 289 red / yellow / green colour 290 blue / white colour 291 providing & fixing of electricalinsulating rubber matts as per pwd specification for electrical works, isi marked confirming to is: 15652 / 2006with one sideanti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 292 11 kv, class b 2.5 mm thick with proof voltage 22 kv ac ( rms ) and break down voltage45 kv ac ( rms ) 293 providing & fixing of self healing ip20 mpp type shunt capacitor ( banks ) conforming to is:13340 41 / iec :831 1&2 or iec : 60831 1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( psd ) and shall have dissipation factor less than 0.0025 at 50 hz, operating loss less than 0.30 watt per kvar. min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, llife expectancy greater than 100000hrs ( temp class 25 d ) in 440 v / 480 v capacitor and for 525 v should life expectancy minimum 1, 65, 000 hrs ( temp class 25 d ) including making connections, testing etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 294 heavy dutythree phase 525v, 50 hzcylindrical typecapacitor ( bank ) 295 providing & fixing of ip54 microprocessor based 3 ct’s for all 3 phasesensing compensationpower factor correction relay size 139mm x 139 mm, operating voltage 415 / 440 v, iec / en 61000 6 ( 2&4 ) having 3 ct sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c / k setting according to targeted power factor setting, the relay shall havedigit display unit for display of real power factor, targeted power factor, lag / lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with rs 485, indication of switching on units, auto / manual status, and shall have over load protection, no volt release , having multi parameter like kw, kva, kvar, rms value, step switching time 2 sec to 1800 sec. lead & lag parameters, metering facility and3 no. class 0.5 cast resinct ( refer ct specs in this chapter ) for sensing the relay including making coonection with 1.5 sq.mm copper wire etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 296 12 to 14 stage 297 providing & fixing ofac operated heavy duty 230 / 440 volt power contactor as per pwd specification for electrical works, isi marked is / iec 60947 4 1 : 2000 having provision of mechanical interlocking, auxilary contacts, din rail mounting type including making connections, testing etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 298 3 pole power contactorswith following ac 3 rating 299 40 amp 300 providing & fixing of440 volt 3 pole capacitor ( ac 6 b ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors / reactors to limit the inrush current as per pwd specification for electrical works, is / iec 60947 4 1 : 2000, insulation voltage 1000v, impulse withstand voltage 8 kv, din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 301 up to 6 kvar 302 10 kvar 303 20.0 kvar 304 providing & fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and ac1 rating of 16 20 amperes including making connection, programming conforming to iec 60730 1 and 60730 2 7 etc. as required.all as per pre approved by engineer in charge. for additional technical parameters of products / work, refer annexure a attached with this bsr . 305 one day & week reserve ( digital type ) 306 sitc of3 / 4pole current limiting moulded case circuit breaker ( mccb ) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440 / 415 v, 50 hz; o / l & s / c settings , conforming to is / iec 60947 p 2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push ( test ) to trip, trip time less then 10 ms under s / c condition, breaking capacity ics = 100% icu. u imp =8 kv, rated insulation voltage690 v.provision for uvr , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.oem shall have submitnabl / cpri / erda accrediated lab type test certificate before execution all as per pre approved by engineer in charge. for additional technical parameters of product / work refer annexure a attached with this bsr 307 3 pole mccb with thermal magnetic release 308 160 amp , 25 ka, adjustable o / l & adjustable s / c setting, 309 4 pole mccb with thermal magnetic release 310 up to 100 amp , 25 ka, adjustable o / l & adjustable s / c setting, 311 125 amp , 25 ka, adjustable o / l & adjustable s / c setting, 312 160 amp , 25 ka, adjustable o / l & adjustable s / c setting, 313 200 amp , 25 ka, adjustable o / l & adjustable s / c setting, 314 250 amp , 35 ka, adjustable o / l & adjustable s / c setting, 315 400 amp , 35 ka, adjustable o / l & adjustable s / c setting, 316 s i t c of star ratedaluminium wound distribution transformerof following rating 11 / 0.433kv delta star connected, vector group dyn 11, onan cooled & as per bee star 1 & bis approved as per is 2026 1977 & lossesas defined as per 2014 ( fourth revision ) level 1 . including standardaccessories like conservator, silica gel breather, radiator, fins, ht cable box & lt cable boxes, temperature rise in winding / oil 35 40 degree c upto 200 kva & 40 45 degree c for above 200 kva, isi marked drain valve, dial type temperature gauge, first filling of transformer oil as per is :335 1953, epoxy based paint, including carrying of pre commission testing & charging of transformer complete in all respect . 317 the transformer shall be subjected to routine factory tests ( as per is:2026 and is:1180 ) including testing from ctlof discombefore charging of transformer & complete installaion must be certified from electrical inspectorate office as per indian electricity rule, ( ctl testing charges and electrical inspection charges shall be reimbursed by the department to the contractor ) . all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 318 250 kva with off ltc ( +5% to 10% @ 2.5% ) 319 sitc of 11kv 630 amps 21ka for 3 sec. sf6 insulated, outdoor duty ( ip54 ) , extensible / non extensible typering main unit ( rmu ) manually operated in combination ofvcb modules andload break switch consisting of copper busbar in sf6 insulated 304 ( non ferrite non magnetic grade ) stainless steel enclosure of thickness 2.5mm with manometer.the hv switchgear and control gear should be confirming to iec 62271 100, iec 62271 200 2003 & iec 60694 1996. the rmu should be internal arc tested for 21ka for 1second with iac afl classification for gas tank. vacum interrupter of vcb should be rmu manufacturer’s own make.each feeder of rmu should have voltage presence indicator. . and compring offollowings: 1 no. microprocessor based self powered numerical relay with over current / earth fault & short circuit protection with each vcb feeder. 3 nos. protection ct shall be of burden 2.5va, ratio 50 / 1a, class of accuracy class 5p10for o / c and e / f protection for each vcb. 1 no. manometer for each tank, 1 nos. fault passage indicator, right angle boots for all the feeder modulesall the type test certificates as per iec from third partynabl / cpri / erda accrediated lab to be submitted. ( cost of rcc foundation / steel structure to be paid extra ) all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr 320 non extensible 3 way rmu with 1 no. vcb & 2 no. load break switch 321 sitc of ht metering cubical panel as approved by discoms fabricated out of 18 swg crca sheet steel in two compartment & ms angle of size 60mmx 6mm having provision for following: ( i ) provision for fixing trivector / import export meter ( to be supplied by discoms ) ( ii ) provision for fixing of combined ct pt set with copper strip for connection ( to be supplied by discoms ) , ( iii ) test terminal block, ( iv ) 6mm thick bakelite sheet on all sides, ( v ) 3 / 6 corex 1.5 / 2.5 sq.mm copper cable for interconnections, etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 322 sitc of radiator cooled and turbo charged silent dg set ( as per latest cpcb emissionnorms ) havingspecifications as per a, b, c, d, e, f, g, h & i 323 a ) 1500 rpm diesel engine conforming to bs:649 / 5514 of suitable bhp ( up to 82.5 kva 6 cylinder or below required, 125 kva & above ratings 6 cylinder or aboverequired ) capable of taking 10% over loading for one hour after 12 hours of continuous operation., dry exhaust mainfold with hospital grade silencer and catalytic convertor ( isolated from main dg chamber ) , up to 3 m exhaust piping ( with lrb insulation & alum. cladding ) as required . 324 b ) ac brush less spdp alternator conform to bs 5000 ( part 99 ) or is / iec 60034 1. . alternator shall be self regulated with standard alternator protection ( over voltage , over speed & under voltage, under speed warning & shutdown ) .engine & alternator mounted on a common base frame & coupled through a flexible coupling or close coupled 325 c ) cpcb / arai approved standard canopy with weatherproof, powdercoated accoustic enclosure for dg set for sound attenuation fabricated from 1.6 mm crca sheet steel ( structure ) with sidewall fabricated from 1.6 mm crca sheet & filled with glasswool ( 96kg / m3 ) / foam. as per is8183 the doors of 28 / 40 / 50 / 85mm thick as perrating and fabricated from 1.6mm crca sheet packed with accoustic material, all doors / opening are sealed with neoprene / epdngaskets. the dg set has inbuilt / external in fuel tank to run 6 to 8 hrs as per oem standard, with protection and tripping of dg set against temperature of more than 50 degree centigrade. 326 d ) electronic / mechanical governor, manual & electric start , batteries with battry charger, engine instruments panel, avm pads all controls for operation of dg set are from outside the enclosure with dg control panel having microprocessor based genset monitoring like running hour, rpm, low lube oil tripping & control system, panel mounted mccb / acb of suitable rating, ammeter, voltmeter, pf meter, frequency meter, kwh meter, digital fuel display meter, ind.lamps etc. mounted inside enclosure , visible and accessible from outside. the enclosure should be suitable for following capacity dg sets and alternator. noise level shall be less than 75 db at a distance of 1 mtrs. duly certified by authorised agency etc. complete in all respect of following capacity : 327 e ) ( i ) accoustic glass wool wall thickness should not be less then 40mm and not less then 20mm pu foam upto rating 100 kva. ( ii ) .accoustic glass wool wall thickness should not be less then 65mm and not less then 50mm pu foam upto rating 250 kva. ( iii ) accoustic glass wool wall thickness should not be less then 100mm forrating above 250 kva. 328 f ) first filling of the fuel tank shall be done by contractor and the prevailing fuel cost at that time shall be reimbursed to the contactor by department. 329 g ) servicing contract of dg set from oems authorised service dealer as per oem guidelines during the dlp period shall be done by contractor including all consumables, actual charges shall be reimbursed to the contractor by end user department. 330 h ) manufacturer / oem must have its authorized service dealer in rajasthan. which can provide service within 6 hours of compalint registration. 331 i ) dg set will be offered for inspection and testing at manufacturers works in presence of departmental engineers. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 332 40 kva at 0.8 pf 415v 50hz 3 ? 333 sitc of plc based auto main failure ( amf ) panel fabricated from crca sheet steel 2 mmthick , powder coated finish , engine start & stopcommands, control relays , ammeter & voltmeterwith selector switches, control & 2 nos 4 pole power contactors with 2 no. of required size 4 pole mccb, timers, electronic hooter , visual & alarm indication for faults, ups, operator interface panel complete in all respect suitable for following capacity dg sets: appropriate test certificate / report of product / accessories from oem / panel manufecturer shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 334 20 to 40 kva 335 supply & fabrication steel structure with ms channel / angle / joist / ismb / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as requiredcomplete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 336 providing and fixing welded mesh / expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 x 50 x 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 ( 30x30x45cm ) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 337 earth work in excavation / by mechanical means ( hydraulic excavator ) / manual means over areas ( exceeding 30 cm in depth, 1.5m in width as well as 10 sum on plan ) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed: 338 random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 ( 1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size ) upto plinth level with cement mortar 1:6 ( 1 cement : 6 sand ) . 339 providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement all work up to plinth level 340 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) 341 plaster on new surface on wall in cement sand mortar 1:4 including racking of joints etc. complete fine finish : 342 20mm thick 343 finishing wall with water proofing cement paint of approved brand and manufacture and or required shadetogive an even shade including all scaffolding: 344 new work ( two or more coats applied @ 3.84 kg / 10 sqm ) . 345 sitc of single stage, water cooled, high speed ( 2880 rpm ) , horizontal, centrifugal, openwell submersible pumps set pre filled with coolent water and fitted with mechanical seal t / c vs t / c, thrust bearing shall be ofcarbon + s.s.the stator body of single phase pumpshall be of ss and rest of all shall be of cast iron. all casting parts should be cathod electro deposition ( ced ) coated and other construction material should be confirming to is : 14220: 2018 . the overall performance of pump shall confirm to bee energy efficiency level of 3 star. valid bee certificate from oem must be submitted for the same. motor should be ie2 class as per iec 60034 2 1: 2007, iec 60034 30: 2008, & is12615:2011, including making connection etc as required complete in all respect. oem shall have submitnabl / cpri / erda accrediatedlab type test certificate before execution. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 346 5.0 hp, 3 ø, ( 14 28 ) mtr, ( 995 500 ) lpm 347 sitc of contactoroem fabricated dol / star delta starter panel with switchgear selection as per type 2 cordinatiom chart andmade out from 1.6 mm thick powder coated crca sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, illuminated on / offpush buttons, ammeter, voltmeter, indicating lamps etc.suitable for following rating motors complete in all respect. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 348 for three phase submersible / mono block pump 349 3.0 hp to 5.0 hp ( dol starter ) 350 part b non bsr items based on market rate 351 sitc ofro water system with filtration stage = particulate filter membrane life enhancer filter sediment filter pre carbon filter ro membrane filter post carbon filter, input power rating 230 v ac , 50 hz, percentage of rejection tds 90% or better having following features ( a ) double purification by ro with ess or latest technology with tds indicator ( b ) .spin welded ro membrane housing to prevent tempering ( c ) . push fit components for leak proof performance ( d ) . fully automatic operation with auto start and auto off ( e ) . ss construction for corrosion free lifespan ( f ) . equally suitable for water from all bore wells, , overhead storage tanks, water tankers and even municipal taps ( g ) ro membrane flushing auto flush @ every start , every stop and every one hourof working for one minute. complete in all respect with following capacity. approved make:eureka forbes, kent, au smith, ion exchange, pentair. 352 purification capacity 50 lph, duty cycle 270 500 liters / day, 353 sitc of dome ip ir cctv cameras: network h.265 2mp ( full hd ) megapixel high frame rate mini dome camera with built in microphone:2mp ir dome camera with metal body and built in mic: 1 / 2.8 progressive scan cmos; resolution: 1920 × 1080@30fps or better; colour: 0.01 lux @ ( f1.2, agc on ) or better, h.265+ compression or better; 120 db true wdr or better; fixed 2.8 / 4mm lens; built in mic; 3d dnr; 40m ir range or better, triple streams; blc, 3d dnr, hlc; line crossing detection, intrusion detection; scene change detection; face detection; anti flicker, heartbeat, mirror, password protection, privacy mask, watermark, ip address filter; onvif ( profile s, profile g ) , isapi; built in micro sd / sdhc / sdxc slot, up to 128 gb or better; operating condition: 30 °c to +60 °c; ip67; 12dc & poe; certificate of compliance: ul, ce / fcc, bis, rohsapproved make: samsung / hikvision / panasonic / infinova / cp plus / dahua / honeywell 354 sitc of ip ir cctv bullet outdoor camera: network h.265 2mp ( full hd ) megapixel high frame rate ir bullet camera ( outdoor ) with metal body, 2mp full frame low light ir bullet camera: 1 / 2.5 progressive scan cmos; resolution: 1920 × 1080 or better; color: 0.002 lux @ ( f1.2, agc on ) or better; slow shutter; fixed 3.6 mm lens; triple streams; 3d dnr; 120db wdr; 50m ir range or better; line crossing detection, intrusion detection, object removal detection, unattended baggage detection, scene change detection; face detection; anti flicker, heartbeat, mirror, password protection, privacy mask, watermark, ip address filter; onvif ( profile s, profile g ) , isapi; roi; support micro sd / sdhc / sdxc card ( 128g ) , local storage and nas ( nfs, smb / cifs ) , anr; operating condition: 30 °c to +60 °c; ip67; 12dc & poe; metal body; built in junction box for cable management; certificate of compliance: ul, ce / fcc, bis / rohs approved make: samsung / hikvision / panasonic / infinova / cp plus / dahua / honeywell 355 sitc of raid 5 supported 32ch nvr with upto 48 tb hdd support 32ch ip inputs; dual os for redundancy; support anr technology;320mbps incoming bandwidth, supports up to 12mp full channel recording; support h.265 compression; 16ch syncronised playback @1080p; support raid 5; n+1 hot spare system; support 3rd party cameras; 4k output; minimum 8 sata hdd slots; each slot should suppport upto 6tb hdd; e sata interface; dual gigabit self adaptive ethernet interface; serial interace; usb interface; alarm in / out;dual power supply ( all cameras and storage nvr should be of same make for the smooth functioning of the system ) . certificate of compliance: ul, ce / fcc, bisapproved make: samsung / hikvision / panasonic / infinova / cp plus / dahua / honeywell 356 sitc of 3.5 6tb surveillance hard disk ( makes: seagate / wd / toshiba ) 357 sitc of workstation latest intel® i5 processor, with 17 led monitor screen intel chipset motherboard, 08 gb ram, 1 tb sata hdd at 7200 rpm, with 4gb gpu type higher end graphic card for h.265 compression technique with dual display ports / dvi / hdmi port, giga lan card, wireless keyboard, wireless optical mouse with original license windows software of approved makes: lenovo, hp, dell. 358 sitc of 55 flat smart screen hd profesional led with remote control and wall mount unit / floor stand complete with making connections etc of approved makes: lg, samsung, panasonic. 359 sitc of 5 kva 1 phase input, 1 phase output advance dsp controlled ups with igbt based rectifier, lcd display, double conversion / digital signal processing ups, with isolationtransformer, with 26ahx x 16 nos smf batteries for min 30 min back up, with ms rack for barreries and required cabling for incoming & outgoing connection of approved makes: numeric, eaton, emerson, apc. 360 supply, installation, testing & commissioning of managed layer 2 intelligent ethernet poe switches providing 08 x 10 / 100 / 1000 fast ethernet poe ports 67w or better and 2 dual purpose uplink ports ( provision for copper / fiber giga connectivity ) all switches & related fiber modules should be of same make & category for seamless integration with each other of approved makes: cisco catalyst series or equivalent in avaya, juniper ) 361 p & f of early streamer emission type lightning arrester on gi mast with air terminal configured as spheroid which is comprised ofseparate electrically isolated 4 panels surrounding an earthed central finial, the terminal shall be tested by cpri for impulse current of 45 ka ( 8 / 20 sec ) with 5 positive & 5 negative impulse, the arrester having following protection radius at level 1 approved makes :lpi ( australia ) , lpsfr ( france ) , sudafix ( uk ) , ef ( switzerland ) , abb 362 30 48 mtr. 363 s & laying of p.v.c. / xlpe insulated & p.v.c. sheathed down conductor of 70 sq.mm single core insulated flexible copper cable confirming to is:1554 p i / is :7098 p i of 1.1 kv withelectrolytic gradecopper made of copper rodsconfirming to is 613 1964, of purity >99.7 %, inner / outer sheath confirming to is:5831 with accessories as required. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810approved makes: polycab, rr, finolex....

RAJASTHAN COUNCIL OF SCHOOL EDUCATION - Rajasthan

36095095 tender for civil work in govt pravisika sanskrit nokha naov part a (building work) based on bsr pwd 2019, bikaner 2 earth work in excavation by mechanical means (hydraulic excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.all kinds of soils 3 pcc in foundation :providing and laying in position cement concrete including curing compaction etc. complete in spcified grade excluding the cost of centering and shuttering all work upto plinth level 1:4:8(1 cement:4 coarse sand :8 graded stone aggregate 40 mm nominal size). 4 brick work masonary with f.p.s bricks of ist class desgnation in foundation and plinth in. cement sand mortar 1:6 ( 1 cement :6 coarse sand) add extra over item of brick workwith class designation 10.0 in substitutionof class designation 7.5 :quantity in cum. 5 plinth beam: providing and laying in position specified grade ofcement concrete forall rcc structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. m20 grade nominal mix / design mix 6 dry brick on edge flooring in required pattern with bricks of class designation 75 on bed of 12 mm mud mortar including filling joints with river sand complite . 7 half brick work : half brik masonary in supperstructure , above plinth level up to floor five level using f.p.s.bricks of designation 75 cement mortar 1:4 (1 cement:4 course sand) 8 flyash brick work: brick work with mechanised autooclaved flyash lime bricks conforming to is: 12894 :2002 of class designation 100 in superstructure above plinth level up to floor five level in cement mortar 1:6. 9 lintel beams: providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( as required) excluding the cost of centering, shuttering and reinforcementfor beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. m20 grade nominal mix / design mix 10 slab & beam: providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( as required) excluding the cost of centering, shuttering and reinforcementfor beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. m20 grade nominal mix / design mix 11 centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 12 steel reinforcement: p/f reinforcement for rcc work including straightening,cutting, bending, placing in position and binding (including cost of binding wire)all complete upto floor five leve tmt bars (conforming of relevent is code). 13 door frames: structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete.angle iron (40x40x5mm. @ 3 kg/m) 14 doors: providing and fixing m.s. sheet 1 mm thickdouble leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of engg. incharge but excluding cost of chowkhats: including two coats of anit corrosive red oxide primer paint. add extra for double leaf shutters 15 glazed window:providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :partly fixed and partly openable [ fixed area not to exceed 33%] 16 wire gauge supplying & fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150 mm distance. 17 guard bars: p&f square bars or other flat welded to window/ventilators etc. 18 kota stone slab flooring 25 mm thick over 20mm ( average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement: 4 course sand ) for area 2001 to 5000 sq. cm 19 kota stone slabs 25 mm thick in risers and stepsskirting, dado and pillars laid on 12 mm (average)thick cement mortar 1:3(1 cement: 3 course sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs , including rubbing and polishing completefor areaof each slab upto2001 sq. cm 20 terrazo tiles over roof: providing and fixing 20 mm thick precast terrazo tiles of approved make, with marble chips of size up to 6 mm laid over roof with neat cement slurry mixed with pigment to match the shade of the tiles , including cutting, grinding rubbing with machine complete on 20 mm thick bed of cement sand mortar 1:4. 21 providing & fixing ist quality standard white, gray, ivory,fume red brown, light green, light blue and other light shades glazed tiles confirming to is : 13753 and is: 15622 of size 300mm x 200mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of tile complete (excluding the cost of cement plaster on walls and piller) 22 internal plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished : 12 mm thick 23 external plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished : 20 mm thick 24 plaster(ceiling): 6 mm thick cement plaster to ceiling of mix 1:3(1 cement: 3 fine sand) 25 black board : plaster on new surface on wall in cement sand mortar 1:3 including raking of joints etc. complete fine finish: 12 mm thick 26 grading roof for water proofing treatment withwater proffing compound: cement concrete 1: 2: 4 (1 cement: 2 course sand: 4 greded stone aggregate 20 mm nominal size) 27 gola: providing gola 75mm x 75mm in cement concrete 1:2:4(1 cement: 2 coarse sand: 4 stoneaggregate 10 mm and down gauge) including finished with cement mortar 1:3(1 cement: 2 fine sand) as per standard design. 28 internal finishing: distempring with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding new work ( two or more coats ) over and including scrapping and priming coat with cement primer. 29 exterior finishing : finishing walls with acrylic smooth exterior paint of rquired shade including all scaffolding .new work ( two or more coat applied @ 1.67 /lit/10 sqm. ) 30 putty: providing and applying white based cement putty over plastered surface to prepare the surface even and smooth complete. 31 painting on doors, windows & ramp raling : painting with syntheitic enamel paint of approved brand and manufacture in all shade to give an even shadenew steel work (2 or more coat on new work). 32 copping: cement concrete flooring 1:2:4 (1 cement: 2 course sand: 4 greded stone aggregate) finishing with a floating coat of neat cement including cement slurry, making of lines or groove etc. complete but excluding the cost of nosing of steps etc. complete : 40 mm thick with 20 mm thick nominal size aggregate. 33 for rain water p&f rigid pvc pipe (is:4985 mark) class ii/ (4 kg. /cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia 34 for rain water p&f rigid pvc pipe fittings (is: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: bend 87.5110mm dia 35 pipe clip110 mm dia 36 providing and laying factory made chamfered edge plastic coated designer cement concrete paver blocks of required strength, thickness & size/shape, made by table vibratory method, to attain superior smooth finish using pu or equivalent moulds, laid in required grey/yellow/red or any other colour & pattern over 50mm thick compacted bed of coarse sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks, lawns, drive ways or light traffic parking etc. all complete as per manufacturer’s specifications & direction of engineer in charge: 37 providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to is : 13753 & is :15622 of size 200mm x 300mm in walls, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 38 providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. 39 part c (sanitary item)provinding and fixing3 layer pp r (polyproylene random copolymer) pipes sdr 7.4 uv stabilized & antimicrobial fusion welded, having thermal stability for hot and cold water supply including all pp r plain and brass threaded polypropylene random fittings and fixing the pipe with clamps at 1.00 spacing. this includes testing of joint complete as per direction of engineer incharge.(internal work exposed on wall)pn 16 pipe, 25 mm od 40 provinding and fixing3 layer pp r (polyproylene random copolymer) pipes sdr 7.4 uv stabilized & antimicrobial fusion welded, having thermal stability for hot and cold water supply including all pp r plain and brass threaded polypropylene random fittings and fixing the pipe with clamps at 1.00 spacing. this includes testing of joint complete as per direction of engineer incharge.(internal work exposed on wall)pn 16 pipe, 16 mm od 41 p & f squatting pan ( indian type ) white glaze viterous china 1st quality w.c. pan ( is: 2556 mark) with 100 mm viterous chinap or s trap including cutting & making good the wall & loor (excluding a pair of foot rest ) size 510 mm 42 p & f wvc wash basin (1st quality, i.s. : 2556 mark) of approved make with c.i. brackets duly painted, 1 no. 15 mm c.p. pillar cock (is : 8934 mark) & 32 mm c.p. brass waste coupling of approved make,25 mm g.i. waste pipe complete including cutting & making good the wall.: 450 x 300 mm 43 p & f bib cock (is : 8931 mark) superior quality of approved make.c.p. brass 400 gm, 15 mm nominal bore. 44 p & f inlet connection (angle valves) superior quality of approved make c.p. intel connection 15 mmbrass(is : 8931) 45 p&f rigid pvc pipe (is:4985 mark) class ii/ (4 kg. /cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia 46 p& f waste coulping with fittings of approved quality /make:c.p. brass 40 mm dia 47 p& f waste pipe with all fittings of approved quality /make: p.v.c. with c.p. nut 40 mm dia 48 p&f rigid pvc pipe fittings (is: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: bend 87.5110mm dia 49 pipe clip110 mm dia 50 p&f rigid pvc pipe fittings (is: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant plain floor trap 110 mm dia 51 p&f rigid pvc pipe fittings (is: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant p trap 110 mm dia 52 p&f rigid pvc pipe fittings (is: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant vent cowel 110 mm dia 53 p & f ist quality wvc urinal ( is:2556 mark) with 25mm dia g.i waste pipe dome couplings, concealed iron brackets or screws etc. complete. 54 s/f rccmain hole covers with frame of approved make (light duty) size 450x450 mm 55 p/f grating of approved quality stainiese steet sheet size 125 mm dia 56 construction of soakage well in alltypes of soil of approved drawing , top 90 cm portion in 450 mm thick with cement mortar 1:6 80 mm stone slab coveringjointing of slab in cm 1 : 3, ralthal, kharanja, 40 mm thick m 15 grade c.c. flooring earthwork etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr.inner dia 90 cm & 10 to 12 m deep 57 construction of chamber in all types of soil with 300 mm thick masnory in cm. 1 : 6, 100 mm thick c.c. 1 : 5 : 10 in foundation , 20 mm thick inside plaster in cm 1 : 6, finished with floating neat cement 50 mm thick m 15 grade c.c. flooring earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr.inside size 300 x 300 mm depth upto 0.5 m & 5 kg ci cover with frame. 58 p & f ball cock (is : 1703 mark) with rod & p.v.c. ball complete.brass wt. 400 gm, 15 mm 59 p & f 15 mm dia connection pipe of approved quality make pvc pipes with nuts 450 mm. 60 p & f stop cock (is:8931 mark),superior quality and of approved mark: brass 400 gm. 15 mm nominal bore 61 p&f gi pipes (external work) with gi fittings excluding union (si: 1239 mark) including trenching and refilling each etc. 15 mm dia nominal bore b class 62 p & f pvc storage tank isi marked ( is: 12701) indicating the bis license no. of approved make with cover, 25mm dia 1 m long g.i. overflow pipe & 25 cm longwash out pipe with plug & socket including making connection etc. complete of approved design 500 litres capacity 63 wiring of light point/fan point/exhaust fan point/ call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvcinsulated unsheathed flexible copper earth conductor 1.1 kv grade (is: 694) of approved make group 2 light point short point (up to 3 mtr.) 64 medium point (up to 6 mtr) 65 long point (up to 10 mtr) 66 fan point short point (up to 3 mtr.) 67 fan point medium point (up to 6 mtr) 68 long point (up to 10 mtr) 69 wiring of 3 pin 5 amp. light plug point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvcinsulated unsheathed flexible copper earth conductor 1.1 kv grade (is: 694) of approved make in surface/reces group on board 70 s & f follwing sizes (dia.) of isi marked medium duty pvc conduit along with accessories in surface/ recessed using clamps, fastener as required including cutting the wall , covering conduit with wire mess and making good the same as required. group 225 mm dia 71 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existing surface ofr necessed conduit/ casting capping including making connections etc. as required. group 2 (1 x 1.5 sq. mm) 72 2 x 1.5 sq. mm 73 2 x 2.5 sq. mm 74 p & f 240/415 v mcb of breaking capacity not less than 10 ka (b/c/d tripping characteristic) isi marked is 8828 (1996)/conforming to iec 60898 in existing board/ sheets including making connections with lugs, testing etc. as required. group 2 6 a to 32 a rating 75 p & f recessed/ surface mounting heavy duty horizontal type sheet steel distribution board phophatised/ powder painted complete with 100 amp copper copper bus bar, shorting link, neutral, earth link and din bar, conforming to is 13032 & is 8623 including making internal db termination with copper lux, testing etc. as reqd. . group 2single door(single phase) 8 way 76 p & f strip fluorscent tube fitting fabricated from (crca sheet and finished with powder coating/stove enamelled non corrosive uv resist ep channel)complete with accessories(low loss copperchoke, starter, starter seat)/electronic choke with terminal block duely prewired with copper conducter including making connection, testing etc. as required(without tube)1x36 watts with occb. group 2 77 p & f fluorscent tube rod in existing fixtures as required, minimum 3 star rating,36/40 watts 78 p/i aying pvc insulated & pvc sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i of groups of approved make in ground as per is:1255 including excavation of 30cm x 75cm size trench, 25cm thick under layer of sand, iind class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size 6 sqmm, 4 core arm 79 p & f star rated double ball beari;ng capacitor start, aluminium bodyand blade ceiling fan with down rod upto 30 cm with 3x1.5 sqmm pvc insulated flexible copper conductor making connection testing etc as required.1200 mm sweep 3 star rated 80 p & f is:371 marked 6 amp suffacetype celling roseinculuding making commection testing etc. grup 2 (e071400) 81 p & f isi marked 6 amp bakelite batten/ angle holder including making connextion testing etc as required 82 p & f 18 swg ms recessed fan box, hexagonal/round of size 130mm dia, depth 75 mm , 12mm dia rad fan hookwith 100mm length extended on eeach side. gourp 1 83 p & f 18 swg sheet steel boxes duly finisded with two coats of red oxide and with earthing terminal of following sizes (nominal size) on surfacae or in recessed as required. 175 mmx 100 mmx60 mm 84 p & f paper phenolic resin bonded laminates confirming to is: 2036 1995 for boxes/frames including making holes for switches etc with brass screws washers/zink plated nut and bolts as required with 3mm thick ...

Malaviya National Institute Of Technology - Rajasthan

33037471 purchase of electrical maintenance item for estate section mnit jaipur 1. 6 amp. flush type switch ( make ssk ( topline ) , anchor ( penta ) , elle, hi fi, vinay ( clair 30 ) , leader ( euro ) , precision ( prime ) , cona ( wawa ) , kolors ( kubik / kom ) , antex ( lk ) ) each 500 2. 16 amp. flush type switch ( make ssk ( topline ) , anchor ( penta ) , elle, hi fi, vinay ( clair 30 ) , leader ( euro ) , precision ( prime ) , cona ( wawa ) , kolors ( kubik / kom ) , antex ( lk ) ) each 500 3. 6amp bell push flush type ( make ssk ( topline ) , anchor ( penta ) , elle, hi fi, vinay ( clair 30 ) , leader ( euro ) , precision ( prime ) , cona ( wawa ) , kolors ( kubik / kom ) , antex ( lk ) ) each 50 4. 6a twin control switch flush type ( make ssk ( topline ) , anchor ( penta ) , elle, hi fi, vinay ( clair 30 ) , leader ( euro ) , precision ( prime ) , cona ( wawa ) , kolors ( kubik / kom ) , antex ( lk ) ) each 50 5. 3 pin 6 amp. flush type socket ( make ssk ( topline ) , anchor ( penta ) , elle, hi fi, vinay ( clair 30 ) , leader ( euro ) , precision ( prime ) , cona ( wawa ) , kolors ( kubik / kom ) , antex ( lk ) ) each 500 6. 3 / 6 pin 16 amp flush type socket ( make ssk ( topline ) , anchor ( penta ) , elle, hi fi, vinay ( clair 30 ) , leader ( euro ) , precision ( prime ) , cona ( wawa ) , kolors ( kubik / kom ) , antex ( lk ) ) each 500 7. 6 amp surface type ceiling rose ( make ssk, anchor, precision, vinay, cona, elle, kolors, north west ) each 100 8. 6 amp bakelite batten / angle holder ( make ssk, anchor, precision, vinay, cona, elle, kolors, north west ) each 300 9. 6 amp bakelite unbreakable 3 pin plug top ( make ssk, anchor, precision, vinay, cona, elle, kolors, north west ) each 50 10. 16 amp bakelite unbreakable 3 pin plug top ( make ssk, anchor, precision, vinay, cona, elle, kolors, north west ) each 50 11. flush type 120 / 280 watt rotary step fan regulator ( make ssk, anchor, precision, vinay, cona, elle, kolors, north west ) each 400 12. fr pvc insulated & unsheathed flexible copper conductor isi marked ( is:694 ) of 1.1 kv grade. 1 x 1.0 sq.mm ( make rr kabel , national, finolex, polycab ) mtr. 8100 13. fr pvc insulated & unsheathed flexible copper conductor isi marked ( is:694 ) of 1.1 kv grade. 1 x 1.5 sq.mm ( make rr kabel , national, finolex, rallison, delton, eon ( indoasian ) , kei, terexal, plaza, anchor, l & t, standard, paramount, empire, orient cab, orbit, hpl, unicab, polycab, havells, diatron ) mtr. 8100 14. fr pvc insulated & unsheathed flexible copper conductor isi marked ( is:694 ) of 1.1 kv grade. 1 x 2.5 sq.mm mtr. 6300 ( make rr kabel , national, finolex, rallison, delton, eon ( indoasian ) , kei, terexal, plaza, anchor, l & t, standard, paramount, empire, orient cab, orbit, hpl, unicab, polycab, havells, diatron ) 15. fr pvc insulated & unsheathed flexible copper conductor isi marked ( is:694 ) of 1.1 kv grade. 1 x 4.0 sq.mm ( make rr kabel , national, finolex, rallison, delton, eon ( indoasian ) , kei, terexal, plaza, anchor, l & t, standard, paramount, empire, orient cab, orbit, hpl, unicab, polycab, havells, diatron ) mtr. 2700.0 16. fr pvc insulated & unsheathed flexible copper conductor isi marked ( is:694 ) of 1.1 kv grade. 1 x 6.0 sq.mm ( make rr kabel , national, finolex, rallison, delton, eon ( indoasian ) , kei, terexal, plaza, anchor, l & t, standard, paramount, empire, orient cab, orbit, hpl, unicab, polycab, havells, diatron ) mtr. 1350.0 17. 1.5 sq.mm 3 core copper round cable ( make rr kabel , national, finolex, rallison, delton, eon ( indoasian ) , kei, terexal, plaza, anchor, l & t, standard, paramount, empire, orient cab, orbit, hpl, unicab, polycab, havells, diatron ) mtr. 800.0 18. 2.5 sq.mm 3 core copper round cable ( make rr kabel , national, finolex, rallison, delton, eon ( indoasian ) , kei, terexal, plaza, anchor, l & t, standard, paramount, empire, orient cab, orbit, hpl, unicab, polycab, havells, diatron ) mtr. 600.0 19. supply of pvc insulated submersible cable confirming to is: 694 with flexible copper conductor 4.0 sq.mm 3 core copper flat ( make rr kabel , national, finolex, rallison, delton, eon ( indoasian ) , kei, terexal, plaza, anchor, l & t, standard, paramount, empire, orient cab, orbit, hpl, unicab, polycab, havells, diatron ) mtr 250.0 20. capacitors 2.5 mfd 250 v ( make: philips, bajaj, havells, cg, osram, usha, punsumi, priya, capital, jec, amcap, concap, epcos, l&t, ge, neptune, abb, schneider ) each 500.0 21. capacitors 4.0 mfd 250 v ( make: philips, bajaj, havells, cg, osram, usha, punsumi, priya, capital, jec, amcap, concap, epcos, l&t, ge, neptune, abb, schneider ) each 125.0 22. supply of starter for existing fluorscent lamp. ( fsu ) ( make:philips, bajaj, cg, wipro, surya, havells, hpl, ge, pierlite, osram ) each 350.0 23. bulb ( gls ) 100 watts ( make:philips, bajaj, cg, wipro, surya, havells, sylvania, osram ) each 150.0 24. supply of medium duty rigid pvc conduit 20mm ( make: akg, bec, precision, polypack, shrinath, polycab, plaza, dauphin, richa ) mtrs 900.0 25. supply of pvc nipple ( suitable for 20 mm pvc conduit ) ( make: akg, bec, precision, polypack, shrinath, polycab, plaza, dauphin, richa ) nos. 540.0 26. supply of pvc bend ( suitable for 20 mm pvc conduit ) ( make: akg, bec, precision, polypack, shrinath, polycab, plaza, dauphin, richa ) nos. 150.0 27. supply of pvc 4 way junction box ( suitable for 20 mm pvc conduit ) ( make: akg, bec, precision, polypack, shrinath, polycab, plaza, dauphin, richa ) nos. 150.0 28. supply of g.i. saddle ( suitable for 20 mm pvc conduit ) ( make: akg, bec, precision, polypack, shrinath, polycab, plaza, dauphin, richa ) packet ( 100 pcs in each ) 10.0 29. supply of pvc saddle ( suitable for 20 mm pvc conduit ) ( make: akg, bec, precision, polypack, shrinath, polycab, plaza, dauphin, packet ( 100 pcs 10.0 richa ) in each ) 30. supply of medium duty rigid pvc conduit 25mm ( make: akg, bec, precision, polypack, shrinath, polycab, plaza, dauphin, richa ) mtrs 900 31. supply of pvc nipple ( suitable for 25 mm pvc conduit ) ( make: akg, bec, precision, polypack, shrinath, polycab, plaza, dauphin, richa ) nos. 540 32. supply of pvc bend ( suitable for 25 mm pvc conduit ) ( make: akg, bec, precision, polypack, shrinath, polycab, plaza, dauphin, richa ) nos. 150 33. supply of pvc 4 way junction box ( suitable for 25 mm pvc conduit ) ( make: akg, bec, precision, polypack, shrinath, polycab, plaza, dauphin, richa ) nos. 150 34. supply of g.i. saddle ( suitable for 25 mm pvc conduit ) ( make: akg, bec, precision, polypack, shrinath, polycab, plaza, dauphin, richa ) packet ( 100 pcs in each ) 10 35. supply of pvc saddle ( suitable for 25 mm pvc conduit ) ( make: akg, bec, precision, polypack, shrinath, polycab, plaza, dauphin, richa ) packet ( 100 pcs in each ) 10 36. supply of 20 mm x 12 mm pvc casing capping ( make: akg, prestoplast, precision, polycab, dauphin, richa, shrinath, polypack, plasoduct, sanco, modi ) mtrs 300 37. supply of pvc bend l ( suitable for 20 mm x 12 mm pvc casing capping ) ( make: akg, prestoplast, precision, polycab, dauphin, richa, shrinath, polypack, plasoduct, sanco, modi ) nos. 90 38. supply of 25 mm x 12 mm pvc casing capping ( make: akg, prestoplast, precision, polycab, dauphin, richa, shrinath, polypack, plasoduct, sanco, modi ) mtrs 300 39. supply of pvc bend l ( suitable for 25 mm x 12 mm pvc casing capping ) ( make: akg, prestoplast, precision, polycab, dauphin, richa, shrinath, polypack, plasoduct, sanco, modi ) nos. 90 40. carbon steel dry wall screw, size: 6x38 mm ( isi marked ) packet ( 800 pcs in each ) 25 41. wall anchor fasteners, size 10 mm x 50mm ( isi marked ) each 150 42. wall anchor fasteners, size 12 mm x 50mm ( isi marked ) each 150 43. electrical insulation self adhesive pvc tap roll ( isi marked ) each 1000 44. roll plug ( 6 mm pvc ) ( isi marked ) packet ( 100 pcs in each ) 200 45. single pole mcb 10 a rating ( make: schneider ( neo break ) , siemens, hpl, ge , standard, indoasian ( gold ) , havells, c & s, abb ( s270 ) , l&t, legrand ( ekinoxe / lexic ) ) each 150 46. single pole mcb 16 a rating ( make: schneider ( neo break ) , siemens, hpl, ge , standard, indoasian ( gold ) , havells, c & s, abb ( s270 ) , l&t, legrand ( ekinoxe / lexic ) ) each 300 47. single pole mcb 25 a rating ( make: schneider ( neo break ) , siemens, hpl, ge , standard, indoasian ( gold ) , havells, c & s, abb ( s270 ) , l&t, legrand ( ekinoxe / lexic ) ) each 300 48. single pole mcb 32 a rating ( make: schneider ( neo break ) , siemens, hpl, ge , standard, indoasian ( gold ) , havells, c & s, abb ( s270 ) , l&t, legrand ( ekinoxe / lexic ) ) each 150 49. double pole isolator 40 a rating each 75 ( make: schneider ( neo break ) , siemens, hpl, ge , standard, indoasian ( gold ) , havells, c & s, abb ( s270 ) , l&t, legrand ( ekinoxe / lexic ) ) 50. double pole isolator 63 a rating ( make: schneider ( neo break ) , siemens, hpl, ge , standard, indoasian ( gold ) , havells, c & s, abb ( s270 ) , l&t, legrand ( ekinoxe / lexic ) ) each 50 51. four pole isolator 40 a rating ( make: schneider ( neo break ) , siemens, hpl, ge , standard, indoasian ( gold ) , havells, c & s, abb ( s270 ) , l&t, legrand ( ekinoxe / lexic ) ) each 50 52. four pole isolator 63 a rating ( make: schneider ( neo break ) , siemens, hpl, ge , standard, indoasian ( gold ) , havells, c & s, abb ( s270 ) , l&t, legrand ( ekinoxe / lexic ) ) each 100 53. four pole isolator 100 a rating ( make: schneider ( neo break ) , siemens, hpl, ge , standard, indoasian ( gold ) , havells, c & s, abb ( s270 ) , l&t, legrand ( ekinoxe / lexic ) ) each 75 54. supply of 240 / 415 v residual current circuit breaker conforming to is:12640:1988 / iec 61008. four pole 30 ma sensitivity 25 a rating ( make: schneider ( neo break ) , siemens, hpl, ge , standard, indoasian ( gold ) , havells, c & s, abb ( s270 ) , l&t, legrand ( ekinoxe / lexic ) ) each 25 55. supply of metal clad industrial plug top & socket unit with pin and sleeve type contact on porcelain / bakelite base in sheet steel enclosure ( without mcb ) single phase / double pole ( three pin ) 32 a ( make : siemens, l&t, havells, standard, hpl, ge, legrand, schneider, abb, bch, indoasian, c&s ) each 70 56. supply of metal clad industrial plug top & socket unit with pin and sleeve type contact on porcelain / bakelite base in sheet steel enclosure ( without mcb ) three phase / four pole 30a 32 a ( make : siemens, l&t, havells, standard, hpl, ge, legrand, schneider, abb, bch, indoasian, c&s ) each 35 57. supply of fluorscent tube rod t5 lamps 28 watts ( make : cg, bajaj, wipro, surya, havells, hpl, ge, pierlite, halonixphilips, cg, bajaj, wipro, surya, havells ) each 250 58. supply of 100 mm x 175 mm and 10 mm thick teak wood board duly antitermite treated, varnished each 150 59. supply of 3 mm thick paper phenolic resin bonded laminates for boxes / frames to cover the wooden box of 100mm x 175 mm and provide the holes to fit one 16 a switch and one 16 a socket. each 150 60. supply of following modular accessories made out of unbreakable and fire retardant poly carbonate ( material required for maintenance of existing accessories ) a. 60.1 6 a one way switch ( make: schneider electric opale x1001 wh ) each 400 b. 60.2 6 a 3 pin shuttered socket ( make: schneider electric opale x2005 wh ) each 250 c. 60.3 6 a two way switch ( make: schneider electric opale x1002 wh ) each 50 d. 60.4 6a bell push switch ( make: schneider electric opale x1005 wh ) each 50 e. 60.5 16 a one way switch ( make: schneider electric opale x1101 wh ) each 400 f. 60.6 16 a 5 / 6 pin shuttered socket ( make: schneider electric opale x2103 wh ) each 250 g. 60.7 25 a shuttered socket ( make: schneider electric opale x2207 wh ) each 150 h. 60.8 32 amp. 2 module switch ( make: schneider electric opale aakx1232 wh ) each 150 i. 60.9 5 step fan regulator 2 module ( make: schneider electric opale x3200 wh ) each 150 j.60.100 supply of mounting grid plates with cover plates 4 module ( make: schneider electric suitable for opale accessories ) each 20 k.60.11 supply of mounting grid plates with cover plates 6module ( make: schneider electric suitable for opale accessories ) each 20 l.60.12 supply of mounting grid plates with cover plates 12 module ( make: schneider electric suitable for opale accessories ) each 20 m. 60.13 6 a one way switch ( make: legrand mylinc ) each 400 n.60.14 6 a 3 pin shuttered socket ( make: legrand mylinc ) each 150 o.60.15 16 a one way switch ( make: legrand mylinc ) each 200 p.60.16 16 a 5 / 6 pin shuttered socket ( make: legrand mylinc ) each 200 q.60.17 5 step fan regulator 1 module ( make: legrand mylinc ) each 150 r.60.18 supply of mounting grid plates with cover plates 4 module ( make: legrand suitable for mylinc accessories ) each 10 s.60.19 supply of mounting grid plates with cover plates 6module ( make: legrand suitable for mylinc accessories ) each 10 t. 6020 supply of mounting grid plates with cover plates 12 module ( make: legrand suitable for mylinc accessories ) each 10 u.60.21 6 a one way switch ( make: anchor woods ) each 150 v.60.22 6 a 3 pin shuttered socket ( make: anchor woods ) each 100 w. 60.23 16 a one way switch ( make: anchor woods ) each 150 x.60.24 16 a 5 / 6 pin shuttered socket ( make: anchor woods ) each 100 y.60.25 5 step fan regulator 1 module ( make: anchor woods ) each 50 z.60.26 6 a one way switch ( make: anchor roma plus ) each 400 aa. 60.27 6 a 3 pin shuttered socket ( make: anchor roma plus ) each 200 bb. 60.28 16 a one way switch ( make: anchor roma plus ) each 400 cc. 60.29 16 a 5 / 6 pin shuttered socket ( make: anchor roma plus ) each 200 dd. 60.30 5 step fan regulator 1 module ( make: anchor roma plus ) each 50 ee. 60.31 supply of mounting grid plates with cover plates 4 module ( make: anchor roma plus suitable for anchor roma plus accessories ) each 40 ff. 60.32 supply of mounting grid plates with cover plates 6module ( make: anchor roma plus suitable for anchor roma plus accessories ) each 40 gg. 60.33 supply of mounting grid plates with cover plates 12 module ( make:anchor roma plus suitable for anchor roma plus accessories ) each 40 hh. 60.34 6 a one way switch ( make: anchor penta ) each 25 ii.60.35 6 a 3 pin shuttered socket ( make: anchor penta ) each 10 jj.60.36 16 a one way switch ( make: anchor penta ) each 25 kk. 60.37 16 a 5 / 6 pin shuttered socket ( make: anchor penta ) each 10 ll.60.38 5 step fan regulator 1 module ( make: anchor penta ) each 10 61. supply of hot dip galvanized m.s. box of 20 swg with earthing terminal suitable for modular accessories 4 module each 40 62. supply of hot dip galvanized m.s. box of 20 swg with earthing terminal suitable for modular accessories 6 module each 40 63. supply of hot dip galvanized m.s. box of 20 swg with earthing terminal suitable for modular accessories 12 module each 40 64. supply of of p.v.c. / xlpe insulated & p.v.c. sheathed armoured cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of approved make 6.0 sqmm 2 core ( make : gloster , cci, finolex, rallison, ekta, delton, havells, kei, paramount, worldcab, diatron, unicab, unistar, orient cab, empire, orbit, polycab, national ) mtr. 500 65. supply of of p.v.c. / xlpe insulated & p.v.c. sheathed armoured cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of approved make 6.0 sqmm 4 core ( make : gloster , cci, finolex, rallison, ekta, delton, havells, kei, paramount, worldcab, diatron, unicab, unistar, orient cab, empire, orbit, polycab, national ) mtr. 500 66. supply of of p.v.c. / xlpe insulated & p.v.c. sheathed armoured cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of approved make 10.0 sqmm 4 core ( make rr kabel, national, finolex ) mtr. 800 67. supply of of p.v.c. / xlpe insulated & p.v.c. sheathed armoured cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of approved make 35.0 sqmm 4 core ( make : gloster , cci, finolex, rallison, ekta, delton, havells, kei, paramount, worldcab, diatron, unicab, unistar, orient cab, empire, orbit, polycab, national ) mtr. 400 68. supply of heavy duty horizontal type sheet steel distribution board phophatised / powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar, masking sheet, conforming to is13032 & is8623 double door ( single phase ) 6 way ( make: schneider ( neo break ) , siemens, hpl, ge , standard, indoasian ( gold ) , havells, c & s, abb ( s270 ) , l&t, legrand ( ekinoxe / lexic ) ) each 16 69. supply of heavy duty horizontal type sheet steel distribution board phophatised / powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar, masking sheet, conforming to is13032 & is8623 double door ( three phase ) 4 way ( make: schneider ( neo break ) , siemens, hpl, ge , standard, indoasian ( gold ) , havells, c & s, abb ( s270 ) , l&t, legrand ( ekinoxe / lexic ) ) each 4.0 70. supply of heavy duty horizontal type sheet steel distribution board phophatised / powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar, masking sheet, conforming to is13032 & each 4.0 is8623 double door ( three phase ) 6 way ( make: schneider ( neo break ) , siemens, hpl, ge , standard, indoasian ( gold ) , havells, c & s, abb ( s270 ) , l&t, legrand ( ekinoxe / lexic ) ) 71. supply of heavy duty sheet steel end box for distribution board duly phophatised powder coated complete as required for tpn 4 way db ( make: schneider ( neo break ) , siemens, hpl, ge , standard, indoasian ( gold ) , havells, c & s, abb ( s270 ) , l&t, legrand ( ekinoxe / lexic ) ) each 10 72. supply of recessed / surface mounting heavy duty vertical type 16 swg sheet steel distribution board with provision of incomer suitable for mccb and sp / tp mcb as outgoing , phophatised , powder painted complete with insulated suitable rating copper bus bar , neutral link, earth link and din bar, masking sheet & conforming to is13032 & is8623 6 way double door with provision of incomer mccb 100a rating ( make: schneider ( neo break ) , siemens, hpl, ge , standard, indoasian ( gold ) , havells, c & s, abb ( s270 ) , l&t, legrand ( ekinoxe / lexic ) ) each 2 73. supply of recessed / surface mounting heavy duty vertical type 16 swg sheet steel distribution board with provision of incomer suitable for mccb and sp / tp mcb as outgoing , phophatised , powder painted complete with insulated suitable rating copper bus bar , neutral link, earth link and din bar, masking sheet & conforming to is13032 & is8623 8 way double door with provision of incomer mccb 100 a rating ( make: schneider ( neo break ) , siemens, hpl, ge , standard, indoasian ( gold ) , havells, c & s, abb ( s270 ) , l&t, legrand ( ekinoxe / lexic ) ) each 4 74. supply of quick make and quick break 4 pole current limiting mccb having following current rating, short circuit breaking capacity at 440 / 415 v, 50 hz; o / l & s / c settings and conforming to is 60947 2 / iec 60947 2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for uvr , shunt trip , earth fault trip, push ( test ) to trip. 100 amp , 16 ka, adjustable o / l & fixed s / c setting, ics = 100 % icu with thermal magnetic release ( make :abb, siemens, ge, l&t, schneider, legrand, c&s, hpl, indoasian, bch ) each 10 75. exhaust fan ( double ball bearing, capacitor start single phase metallic blade fresh air fan ) 300 mm ( make : almonard, cg, alstom, khaitan, usha, havells ) nos. 40 76. supply of air circulator wall fan 450 mm 3 blade, aluminium alloy one piece blade, double ball bearing 90 degree oscillation, three speed, 230 volts, 1440 rpm, 100 watts. ( make: almonard, havells, bajaj, crompton, alstom ) nos. 10 77. supply of 250 mm sweep ventilating fans, capacitor start, single phase with pvc impeller, abs body, automatic openable louver shutter ( make: almonard, havells, bajaj, crompton, alstom ) nos. 50 78. supply of ip40 led recessed, round non dimmable led downlight with die cast aluminum housing & heat sink for heat dissipation with uv stabilized non yellowish diffuser with internal / external bis complience 2.5kv surge protected isolated driver, with short & open circuit protection, having efficiency > 85% and incompliance to iec standards. system lumen efficacy of ≥ 120lm / watt, thd<10%, p.f.≥0.95, cri>80, life time of minimum 50000 burning hourswith, 70% of intial lumen maintaned till life ends, cct 6000°k , maximum power consumption should not more than the specified rating and fixture shall be of bis standard and trade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing on housing. nos. 60 15 watts round 6 dia recessed led down ligther ( make : cg, bajaj, wipro, surya, havells, hpl, ge, pierlite, halonixphilips, cg, bajaj, wipro, surya, havells ) 79. supply of box type t 5 tube fitting fabricated from polycarbonate complete with accessories electronic choke with terminal block duly prewired with copper conductor including making connection ( with tube ) . 1 x 28 watts with eb ( make : cg, bajaj, wipro, surya, havells, hpl, ge, pierlite, halonixphilips, cg, bajaj, wipro, surya, havell...

Department Of Local Bodies - Rajasthan

30453634 renovation work by installing decorative pole and post top led lights on heritage walk way in jaipur municipal corporation heritage area financial year 2021 22 , ( 44.1 ) supplying and drawing fr pvc insulated & unsheathed flexible copper conductor isi marked ( is:694 ) of 1.1 kv grade and approved make in existing surface or recessed conduit / casing capping including making connections etc. as required. , ( 44.1.7 ) 2 x 2.5 sq.mm , ( 45.2 ) p & f in position frame made out of m.s. angle ( riveted or welded ) finished with two coats of red oxide and enamel paint of following sizes as required. , ( 45.2.5 ) 50mm x 50mm x 6mm , ( 45.5 ) p & f sheet for boxes / frames including making holes for switches etc, with brass screws, washers / zinc plated nut and bolts as required. , ( 45.6 ) 3.0 mm thick synthetic phenolic resin bonded laminates confirming to is:2046 bakelite sheet , ( 46.6.2 ) 6.4 mm thick , ( 46.1 ) p&f 240 / 415 v mcb of breaking capacity not less than 10 ka ( b / c / d tripping characteristic ) isi marked is 8828 ( 1996 ) ] / conforming to iec 60898 in existing board / sheets including making connections with lugs, testing etc. as required. , ( 46.1.1 ) single pole mcb , ( 46.1.1.2 ) 6 a to 32 a rating , ( 48.1 ) sitc of walll / free standing floor mounted dust and vermin proofcompartmentalised cubical panel made out of crca sheet, required hardware, duly painted by two coats of zinc / red oxide primer followed by powder coated / epoxy / pu painted with phosphatisation in grey or required shade after rinsing. the panel having pu / neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate m.s. base channel, hinged door with locking arrangement for equipment / switchgear. thickness of sheet shall not be less than 1.6mm up to 600mm length / width of any compartment and be of 2.0mm above 600mm. load bearing structure shall be of 2.0mm thick sheet supported by base m.s.channel if required. side walls and cable alley compartments having bolted type doors with detachable extension type structure ( only outer area on all sides shall be measured and panel to be fabricated from cpri approved fabricator ) . , ( 48.2 ) supplying and fixing of aluminium / copper bus bar by means of smc / dmc type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable pvc sleeves , ( 48.2.1 ) electrolytic grade aluminium bus bar , ( 48.15 ) p & f of ac operated heavy duty 230 / 440 volt power contactor conforming to is:13947 4 1 / iec:947 4 1having provision of mechanical interlocking, din rail mounting type including making connections, testing etc. as required. , ( 48.15.2 ) 4 pole ac 1 rating contactors , ( 48.15.2.4 ) 46 to 60 amp , ( 48.20 ) p&f of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and ac1 rating of 16 20 amperes including making connection, programming etc. as required , ( 48.20.3 ) one day & week reserve ( digital type ) , ( 51.1 ) providing & laying xlpe insulated / p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor armoured of is:7098 i / 1554 1 approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. , ( 51.1.4 ) 10.0 sq.mm , ( 51.1.4.1 ) 2 core , ( 51.1.5 ) 16.0 sq.mm , ( 51.1.5.3 ) 4 core , ( 52.8 ) supplying and making one end termination with heavy duty double compression brass gland sibg type, aluminium lugs duly crimped with crimping tool, pvc tape etc for following size of armoured pvc insulated & pvc sheathed / xlpe aluminium conductor cable of 1100 volt grade as required of size. , ( 52.8.4 ) 2 x 10.0 sq.mm , ( 52.8.42 ) 4 x 16.0 sq.mm , ( 54.15 ) maintenance free gel earthing with pipe in pipe / strip in pipe technology filled with anti corrosive conductive compound ( cpri tested ) below the ground in 150 200 mm dia earth pit and surrounding filled with required mineral filling compound ( mfc should have hygroscopic proper ty to retain the moisture for long time to create low resistance zone ) and c.c. finished chamber covered with hinge type with locking arrangement c.i cover. c.i. frame of size 300mm x300mm complete testing of earth resistance as required of following sizes with pipe in pipe technology ( inner pipe dia / outer pipe dia ) 80 100 micron g.i.coating , ( 54.15.1 ) with pipe in pipe technology with 80 100 micron g.i. coating , ( 54.15.1.2 ) g.i. pipe 2000 mm long , 80 / 40 mm , terminal 12 mm g.i. strip , ( 49.7 ) sitc of quick make and quick break 4 pole current limiting mccb having following current rating, short circuit breaking capacity at 440 / 415 v, 50 hz; o / l & s / c settings and conforming to is 13947 2 / iec 60947 2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for uvr , shunt trip , earth fault trip, push ( test ) to trip , including making connections with lugs / spreaders etc. as required , ( 49.7.1 ) with thermal magnetic release , ( 49.7.1.2 ) up to 100 amp , 16 / 25 ka, adjustable o / l & fixed s / c setting...

RAJASTHAN COUNCIL OF SCHOOL EDUCATION - Rajasthan

30055123 construction of school work sulkhania civil work at gsss, sulkhnia chhota block rajgarh sl. no. item description 1 part a civil work 2 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sum on plan ) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.all kinds of soils 3 p.c.c. in foundation providing and laying in position cement concrete including curing compaction etc. complete in spcified grade excluding the cost of centering and shuttering all work upto plinth level 1:4:8 ( 1 cement:4 coarse sand :8 gradeed stone aggregate 40 mm nominal size ) . 4 brick work masonary with f.p.s bricks of ist class desgnation in foundation and plinth in. cement sand mortar 1:6 ( 1 cement :6 coarse sand ) 5 dpc: providing and laying in position specified grade of cement concrete for all rcc structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 ( 1 cement: 3 coarse sand ) and making good the joints and cost of plastizers ( if required excluding the cost of centering, shuttering and reinforcement . m20 grade nominal mix / design mix. 6 supply & stacking good earth at site complete including loading unloading & transporation etc. 7 brick work masonary with f.p.s bricks of ist class desgnation in supersture above plinth level upto floor vth level in all shapes and sizes in cement mortar 1:6 ( 1 cement :6 coarse sand ) 8 pillar masonary : brick work masonary with f.p.s bricks of ist class desgnation in supersture above plinth level upto floor vth level in all shapes and sizes in cement mortar 1:4 ( 1 cement :4 coarse sand ) 9 stone kharanja: rr dry stone kharanja under floor 10 lintel beams: providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 ( 1 cement: 3 coarse sand ) and making good the joints and cost of plastizers ( as required ) excluding the cost of centering, shuttering and reinforcementfor beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. m20 grade nominal mix / design mix 11 slab & beam: providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 ( 1 cement: 3 coarse sand ) and making good the joints and cost of plastizers ( as required ) excluding the cost of centering, shuttering and reinforcementfor beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. m20 grade nominal mix / design mix 12 centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchorblocks, sills, chhajjas, lintel, beam, plinth beam etc. 13 steel reinforcement: p / f reinforcement for rcc work including straightening, cutting, bending, placing in position and binding ( including cost of binding wire ) all complete upto floor five leve tmt bars ( conforming of relevent is code ) . 14 door frames: structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m ) , fixing in position and applying a priming coat of approved steel primer all complete.angle iron ( 40x40x5mm. @ 3 kg / m ) 15 doors: providing and fixing m.s. sheet 1 mm thickdouble leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of engg. incharge but excluding cost of chowkhats: including two coats of anit corrosive red oxide primer paint. add extra for double leaf shutters 16 glazed window:providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 ( 1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size ) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :partly fixed and partly openable [ fixed area not to exceed 33% ] 17 wire gauge supplying & fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150 mm distance. 18 guard bars: p&f square bars or other flat welded to window / ventilators etc. 19 kota stone slab flooring 25 mm thick over 20 mm ( average ) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 ( 1 cement : 4 coarse sand ) for area of each slab from 2001 to 5000 sq.cm 20 kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average ) thick cement mortar 1:3 ( 1 cement 3 coarse sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete ( for area of each slab upto 2001sqcm ) 21 internal plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished : 12 mm thick 22 external plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished : 20 mm thick 23 plaster ( ceiling ) : 6 mm thick cement plaster to ceiling of mix 1:3 ( 1 cement: 3 fine sand ) 24 black board : plaster on new surface on wall in cement sand mortar 1:3 including raking of joints etc. complete fine finish: 12 mm thick 25 grading roof for water proofing treatment withwater proffing compound: cement concrete 1: 2: 4 ( 1 cement: 2 course sand: 4 greded stone aggregate 20 mm nominal size ) 26 gola: providing gola 75mm x 75mm in cement concrete 1:2:4 ( 1 cement: 2 coarse sand: 4 stoneaggregate 10 mm and down gauge ) including finished with cement mortar 1:3 ( 1 cement: 2 fine sand ) as per standard design. 27 white washing three or more coats to give an even shade on new surfaces . 28 inernal finishing: distempering with dry distemper of approved brand shade ( two or more coats ) of requiredshade new work , over and including priming coat of whiting to give an even shade including all scaffolding. 29 exterior finishing: finishing wall with water proofing cement paint of appd brand & manufacture and of reqd. shade to give an even shade including all scafolding new work ( three or more coats applied at the rate of 3.84 kg / 10 sqm ) 30 painting on doors, windows & ramp raling : painting with syntheitic enamel paint of approved brand and manufacture in all shade to give an even shadenew steel work ( 2 or more coat on new work ) . 31 copping: cement concrete flooring 1:2:4 ( 1 cement: 2 course sand: 4 greded stone aggregate ) finishing with a floating coat of neat cement including cement slurry, making of lines or groove etc. complete but excluding the cost of nosing of steps etc. complete : 40 mm thick with 20 mm thick nominal size aggregate. 32 for rain water p&f rigid pvc pipe ( is:4985 mark ) class ii / ( 4 kg. / cm2. ) approved quality / makeincluding joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia 33 for rain water p&f rigid pvc pipe fittings ( is: 4985 mark ) of approved quality / make including joining the pipe with solvent cement rubber ring and lubricant: bend 87.5110mm dia 34 pipe clip110 mm dia 35 part b electrical work 36 wiring of light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvcinsulated unsheathed flexible copper earth conductor 1.1 kv grade ( is: 694 ) of approved make group 2 37 light point 38 short point ( up to 3 mtr. ) 39 medium point ( up to 6 mtr ) 40 long point ( up to 10 mtr ) 41 fan point 42 short point ( up to 3 mtr. ) 43 medium point ( up to 6 mtr ) 44 long point ( up to 10 mtr ) 45 wiring of 3 pin 5 amp. light plug point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvcinsulated unsheathed flexible copper earth conductor 1.1 kv grade ( is: 694 ) of approved make in surface / reces group on board 46 s & f follwing sizes ( dia. ) of isi marked medium duty pvc conduit along with accessories in surface / recessed using clamps, fastener as required including cutting the wall , covering conduit with wire mess and making good the same as required. group 225 mm dia 47 supplying and drawi;ng fr pvc insulated & unsheathed flexible copper conductor isi marked ( is:694 ) of 1.1 kv grade and approved make in existing surface ofr necessed conduit / casting capping including making connections etc. as required. group 2 48 1 x 1.5 sq. mm 49 2 x 1.5 sq. mm 50 2 x 2.5 sq. mm 51 p & f 240 / 415 v mcb of breaking capacity not less than 10 ka ( b / c / d tripping characteristic ) isi marked is 8828 ( 1996 ) / conforming to iec 60898 in existing board / sheets including making connections with lugs, testing etc. as required. group 2 6 a to 32 a rating 52 p & f recessed / surface mounting heavy duty horizontal type sheet steel distribution board phophatised / powder painted complete with 100 amp copper copper bus bar, shorting link, neutral, earth link and din bar, conforming to is 13032 & is 8623 including making internal db termination with copper lux, testing etc. as reqd. . group 2single door ( single phase ) 8 way 53 p & f strip fluorscent tube fitting fabricated from ( crca sheet and finished with powder coating / stove enamelled non corrosive uv resist ep channel ) complete with accessories ( low loss copperchoke, starter, starter seat ) / electronic choke with terminal block duely prewired with copper conducter including making connection, testing etc. as required ( without tube ) 1x36 watts with occb. group 2 54 p & f fluorscent tube rod in existing fixtures as required, minimum 3 star rating, 36 / 40 watts 55 p / i aying pvc insulated & pvc sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i of groups of approved make in ground as per is:1255 including excavation of 30cm x 75cm size trench, 25cm thick under layer of sand, iind class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size 6 sqmm, 4 core arm 56 p & f star rated double ball beari;ng capacitor start, aluminium bodyand blade ceiling fan with down rod upto 30 cm with 3x1.5 sqmm pvc insulated flexible copper conductor making connection testing etc as required.1200 mm sweep 3 star rated 57 p & f is:371 marked 6 amp suffacetype celling roseinculuding making commection testing etc. grup 2 ( e071400 ) 58 p & f isi marked 6 amp bakelite batten / angle holder including making connextion testing etc as required 59 p & f 18 swg ms recessed fan box, hexagonal / round of size 130mm dia, depth 75 mm , 12mm dia rad fan hookwith 100mm length extended on eeach side. gourp 1 60 p & f 18 swg sheet steel boxes duly finisded with two coats of red oxide and with earthing terminal of following sizes ( nominal size ) on surfacae or in recessed as required. 175 mmx 100 mmx60 mm 61 p & f paper phenolic resin bonded laminates confirming to is: 2036 1995 for boxes / frames including making holes for switches etc with brass screws washers / zink plated nut and bolts as required with 3mm thick 62 p & f socket size flush type 120 / 280 watt rotary 5 step fan regulator including making connection testing etc. as required. 63 p & f socket size flush type 120 / 280 watt rotary 5 step fan regulator including making connection testing etc. as required....

RAJASTHAN COUNCIL OF SCHOOL EDUCATION - Rajasthan

30055097 construction of school work sadasar 4 civil work at gsss, sadasar acr 4 block sardarshahar sl. no. item description 1 part a civil work 2 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sum on plan ) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.all kinds of soils 3 p.c.c. in foundation providing and laying in position cement concrete including curing compaction etc. complete in spcified grade excluding the cost of centering and shuttering all work upto plinth level 1:4:8 ( 1 cement:4 coarse sand :8 gradeed stone aggregate 40 mm nominal size ) . 4 brick work masonary with f.p.s bricks of ist class desgnation in foundation and plinth in. cement sand mortar 1:6 ( 1 cement :6 coarse sand ) 5 chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand light shade using shade cement. ) 6 dpc: providing and laying in position specified grade of cement concrete for all rcc structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 ( 1 cement: 3 coarse sand ) and making good the joints and cost of plastizers ( if required excluding the cost of centering, shuttering and reinforcement . m20 grade nominal mix / design mix. 7 supply & stacking good earth at site complete including loading unloading & transporation etc. 8 brick work masonary with f.p.s bricks of ist class desgnation in supersture above plinth level upto floor vth level in all shapes and sizes in cement mortar 1:6 ( 1 cement :6 coarse sand ) 9 pillar masonary : brick work masonary with f.p.s bricks of ist class desgnation in supersture above plinth level upto floor vth level in all shapes and sizes in cement mortar 1:4 ( 1 cement :4 coarse sand ) 10 stone kharanja: rr dry stone kharanja under floor 11 lintel beams: providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 ( 1 cement: 3 coarse sand ) and making good the joints and cost of plastizers ( as required ) excluding the cost of centering, shuttering and reinforcementfor beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. m20 grade nominal mix / design mix 12 slab & beam: providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 ( 1 cement: 3 coarse sand ) and making good the joints and cost of plastizers ( as required ) excluding the cost of centering, shuttering and reinforcementfor beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. m20 grade nominal mix / design mix 13 centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchorblocks, sills, chhajjas, lintel, beam, plinth beam etc. 14 steel reinforcement: p / f reinforcement for rcc work including straightening, cutting, bending, placing in position and binding ( including cost of binding wire ) all complete upto floor five leve tmt bars ( conforming of relevent is code ) . 15 door frames: structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m ) , fixing in position and applying a priming coat of approved steel primer all complete.angle iron ( 40x40x5mm. @ 3 kg / m ) 16 doors: providing and fixing m.s. sheet 1 mm thickdouble leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of engg. incharge but excluding cost of chowkhats: including two coats of anit corrosive red oxide primer paint. add extra for double leaf shutters 17 glazed window:providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 ( 1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size ) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :partly fixed and partly openable [ fixed area not to exceed 33% ] 18 wire gauge supplying & fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150 mm distance. 19 guard bars: p&f square bars or other flat welded to window / ventilators etc. 20 kota stone slab flooring 25 mm thick over 20 mm ( average ) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 ( 1 cement : 4 coarse sand ) for area of each slab from 2001 to 5000 sq.cm 21 kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average ) thick cement mortar 1:3 ( 1 cement 3 coarse sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete ( for area of each slab upto 2001sqcm ) 22 internal plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished : 12 mm thick 23 external plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished : 20 mm thick 24 plaster ( ceiling ) : 6 mm thick cement plaster to ceiling of mix 1:3 ( 1 cement: 3 fine sand ) 25 black board : plaster on new surface on wall in cement sand mortar 1:3 including raking of joints etc. complete fine finish: 12 mm thick 26 grading roof for water proofing treatment withwater proffing compound: cement concrete 1: 2: 4 ( 1 cement: 2 course sand: 4 greded stone aggregate 20 mm nominal size ) 27 gola: providing gola 75mm x 75mm in cement concrete 1:2:4 ( 1 cement: 2 coarse sand: 4 stoneaggregate 10 mm and down gauge ) including finished with cement mortar 1:3 ( 1 cement: 2 fine sand ) as per standard design. 28 white washing three or more coats to give an even shade on new surfaces . 29 inernal finishing: distempering with dry distemper of approved brand shade ( two or more coats ) of requiredshade new work , over and including priming coat of whiting to give an even shade including all scaffolding. 30 exterior finishing: finishing wall with water proofing cement paint of appd brand & manufacture and of reqd. shade to give an even shade including all scafolding new work ( three or more coats applied at the rate of 3.84 kg / 10 sqm ) 31 painting on doors, windows & ramp raling : painting with syntheitic enamel paint of approved brand and manufacture in all shade to give an even shadenew steel work ( 2 or more coat on new work ) . 32 copping: cement concrete flooring 1:2:4 ( 1 cement: 2 course sand: 4 greded stone aggregate ) finishing with a floating coat of neat cement including cement slurry, making of lines or groove etc. complete but excluding the cost of nosing of steps etc. complete : 40 mm thick with 20 mm thick nominal size aggregate. 33 for rain water p&f rigid pvc pipe ( is:4985 mark ) class ii / ( 4 kg. / cm2. ) approved quality / makeincluding joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia 34 for rain water p&f rigid pvc pipe fittings ( is: 4985 mark ) of approved quality / make including joining the pipe with solvent cement rubber ring and lubricant: bend 87.5110mm dia 35 pipe clip110 mm dia 36 supply & fixing of stainless steel pipe railing for ramp railing height, 90 cm. with 40 mm dia stainless steel pipe with 18 gauge with drop ( vertical post ) at 90 cm c / c and intermidiate horizontal pipe with suitable height of same size and gauge with coupling, grinding and polishing & fix of master pieces as per required point as per approved design of engineer incharge. 37 providing and fixing 20 mm thick precast terrazo tiles of approved make, with marble chips of size upto 6mm laid over roof with neat cement slurry mixed with pigment to match the shade of the tiles, including cutting , grinding rubbing with machinecomplete on 20 mm thick bed of cement sand mortar 1 : 4. 38 part b electrical work 39 wiring of light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvcinsulated unsheathed flexible copper earth conductor 1.1 kv grade ( is: 694 ) of approved make group 2 40 light point 41 short point ( up to 3 mtr. ) 42 medium point ( up to 6 mtr ) 43 long point ( up to 10 mtr ) 44 fan point 45 short point ( up to 3 mtr. ) 46 medium point ( up to 6 mtr ) 47 long point ( up to 10 mtr ) 48 wiring of 3 pin 5 amp. light plug point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvcinsulated unsheathed flexible copper earth conductor 1.1 kv grade ( is: 694 ) of approved make in surface / reces group on board 49 s & f follwing sizes ( dia. ) of isi marked medium duty pvc conduit along with accessories in surface / recessed using clamps, fastener as required including cutting the wall , covering conduit with wire mess and making good the same as required. group 225 mm dia 50 supplying and drawi;ng fr pvc insulated & unsheathed flexible copper conductor isi marked ( is:694 ) of 1.1 kv grade and approved make in existing surface ofr necessed conduit / casting capping including making connections etc. as required. group 2 51 1 x 1.5 sq. mm 52 2 x 1.5 sq. mm 53 2 x 2.5 sq. mm 54 p & f 240 / 415 v mcb of breaking capacity not less than 10 ka ( b / c / d tripping characteristic ) isi marked is 8828 ( 1996 ) / conforming to iec 60898 in existing board / sheets including making connections with lugs, testing etc. as required. group 2 6 a to 32 a rating 55 p & f recessed / surface mounting heavy duty horizontal type sheet steel distribution board phophatised / powder painted complete with 100 amp copper copper bus bar, shorting link, neutral, earth link and din bar, conforming to is 13032 & is 8623 including making internal db termination with copper lux, testing etc. as reqd. . group 2single door ( single phase ) 8 way 56 p & f strip fluorscent tube fitting fabricated from ( crca sheet and finished with powder coating / stove enamelled non corrosive uv resist ep channel ) complete with accessories ( low loss copperchoke, starter, starter seat ) / electronic choke with terminal block duely prewired with copper conducter including making connection, testing etc. as required ( without tube ) 1x36 watts with occb. group 2 57 p & f fluorscent tube rod in existing fixtures as required, minimum 3 star rating, 36 / 40 watts 58 p / i aying pvc insulated & pvc sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i of groups of approved make in ground as per is:1255 including excavation of 30cm x 75cm size trench, 25cm thick under layer of sand, iind class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size 6 sqmm, 4 core arm 59 p & f star rated double ball beari;ng capacitor start, aluminium bodyand blade ceiling fan with down rod upto 30 cm with 3x1.5 sqmm pvc insulated flexible copper conductor making connection testing etc as required.1200 mm sweep 3 star rated 60 p & f is:371 marked 6 amp suffacetype celling roseinculuding making commection testing etc. grup 2 ( e071400 ) 61 p & f isi marked 6 amp bakelite batten / angle holder including making connextion testing etc as required 62 p & f 18 swg ms recessed fan box, hexagonal / round of size 130mm dia, depth 75 mm , 12mm dia rad fan hookwith 100mm length extended on eeach side. gourp 1 63 p & f 18 swg sheet steel boxes duly finisded with two coats of red oxide and with earthing terminal of following sizes ( nominal size ) on surfacae or in recessed as required. 175 mmx 100 mmx60 mm 64 p & f paper phenolic resin bonded laminates confirming to is: 2036 1995 for boxes / frames including making holes for switches etc with brass screws washers / zink plated nut and bolts as required with 3mm thick 65 p & f socket size flush type 120 / 280 watt rotary 5 step fan regulator including making connection testing etc. as required. 66 p & f socket size flush type 120 / 280 watt rotary 5 step fan regulator including making connection testing etc. as required....

RAJASTHAN COUNCIL OF SCHOOL EDUCATION - Rajasthan

30055059 construction of school dhigarla name of work: civil work at gsss, dhigarla block rajgarh 1.01 part a civil work 1.02 earth work in excavation by mechanical means (hydraulic excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.all kinds of soils 1.03 p.c.c. in foundation providing and laying in position cement concrete including curing compaction etc. complete in spcified grade excluding the cost of centering and shuttering all work upto plinth level 1:4:8(1 cement:4 coarse sand :8 gradeed stone aggregate 40 mm nominal size). 1.04 brick work masonary with f.p.s bricks of ist class desgnation in foundation and plinth in. cement sand mortar 1:6 ( 1 cement :6 coarse sand) 1.05 chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand light shade using shade cement.) 1.06 dpc: providing and laying in position specified grade of cement concrete for all rcc structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required excluding the cost of centering, shuttering and reinforcement . m20 grade nominal mix/design mix. 1.07 supply & stacking good earth at site complete including loading unloading & transporation etc. 1.08 brick work masonary with f.p.s bricks of ist class desgnation in supersture above plinth level upto floor vth level in all shapes and sizes in cement mortar 1:6 ( 1 cement :6 coarse sand) 1.09 pillar masonary : brick work masonary with f.p.s bricks of ist class desgnation in supersture above plinth level upto floor vth level in all shapes and sizes in cement mortar 1:4 ( 1 cement :4 coarse sand) 1.10 stone kharanja: rr dry stone kharanja under floor 1.11 lintel beams: providing and laying in position specified grade of cement concrete for rcc structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( as required) excluding the cost of centering, shuttering and reinforcement for beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. m20 grade nominal mix / design mix 1.12 slab & beam: providing and laying in position specified grade of cement concrete for rcc structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( as required) excluding the cost of centering, shuttering and reinforcement for beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. m20 grade nominal mix / design mix 1.13 centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. 1.14 steel reinforcement: p/f reinforcement for rcc work including straightening,cutting, bending, placing in position and binding (including cost of binding wire) all complete upto floor five leve tmt bars (conforming of relevent is code). 1.15 door frames: structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. angle iron (40x40x5mm. @ 3 kg/m) 1.16 doors: providing and fixing m.s. sheet 1 mm thick double leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of engg. incharge but excluding cost of chowkhats: including two coats of anit corrosive red oxide primer paint. add extra for double leaf shutters 1.17 glazed window:providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :partly fixed and partly openable [ fixed area not to exceed 33%] 1.18 wire gauge supplying & fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150 mm distance. 1.19 guard bars: p&f square bars or other flat welded to window/ventilators etc. 1.20 kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) for area of each slab from 2001 to 5000 sq.cm 1.21 kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete(for area of each slab upto 2001 sqcm) 1.22 internal plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished : 12 mm thick 1.23 external plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished : 20 mm thick 1.24 plaster(ceiling): 6 mm thick cement plaster to ceiling of mix 1:3 (1 cement: 3 fine sand) 1.25 black board : plaster on new surface on wall in cement sand mortar 1:3 including raking of joints etc. complete fine finish: 12 mm thick 1.26 grading roof for water proofing treatment with water proffing compound: cement concrete 1: 2: 4 (1 cement: 2 course sand: 4 greded stone aggregate 20 mm nominal size) 1.27 gola: providing gola 75mm x 75mm in cement concrete 1:2:4(1 cement: 2 coarse sand: 4 stone aggregate 10 mm and down gauge) including finished with cement mortar 1:3(1 cement: 2 fine sand) as per standard design. 1.28 white washing three or more coats to give an even shade on new surfaces . 1.29 inernal finishing: distempering with dry distemper of approved brand shade ( two or more coats ) of required shade new work , over and including priming coat of whiting to give an even shade including all scaffolding. 1.30 exterior finishing: finishing wall with water proofing cement paint of appd brand & manufacture and of reqd. shade to give an even shade including all scafolding new work (three or more coats applied at the rate of 3.84 kg/10 sqm) 1.31 painting on doors, windows & ramp raling : painting with syntheitic enamel paint of approved brand and manufacture in all shade to give an even shade new steel work (2 or more coat on new work). 1.32 copping: cement concrete flooring 1:2:4 (1 cement: 2 course sand: 4 greded stone aggregate) finishing with a floating coat of neat cement including cement slurry, making of lines or groove etc. complete but excluding the cost of nosing of steps etc. complete : 40 mm thick with 20 mm thick nominal size aggregate. 1.33 for rain water p&f rigid pvc pipe (is:4985 mark) class ii/ (4 kg. /cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia 1.34 for rain water p&f rigid pvc pipe fittings (is: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: bend 87.5 110mm dia 1.35 pipe clip 110 mm dia 1.36 supply & fixing of stainless steel pipe railing for ramp railing height, 90 cm. with 40 mm dia stainless steel pipe with 18 gauge with drop ( vertical post) at 90 cm c/c and intermidiate horizontal pipe with suitable height of same size and gauge with coupling, grinding and polishing & fix of master pieces as per required point as per approved design of engineer incharge. 2.00 part b electrical work 2.01 wiring of light point/fan point/exhaust fan point/ call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade (is: 694) of approved make group 2 2.02 light point 2.03 short point (up to 3 mtr.) 2.04 medium point (up to 6 mtr) 2.05 long point (up to 10 mtr) 2.06 fan point 2.07 short point (up to 3 mtr.) 2.08 medium point (up to 6 mtr) 2.09 long point (up to 10 mtr) 2.10 wiring of 3 pin 5 amp. light plug point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade (is: 694) of approved make in surface/reces group on board 2.11 s & f follwing sizes (dia.) of isi marked medium duty pvc conduit along with accessories in surface/ recessed using clamps, fastener as required including cutting the wall , covering conduit with wire mess and making good the same as required. group 2 25 mm dia 2.12 supplying and drawi;ng fr pvc insulated & unsheathed flexible copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existing surface ofr necessed conduit/ casting capping including making connections etc. as required. group 2 2.13 1 x 1.5 sq. mm 2.14 2 x 1.5 sq. mm 2.15 2 x 2.5 sq. mm 2.16 p & f 240/415 v mcb of breaking capacity not less than 10 ka (b/c/d tripping characteristic) isi marked is 8828 (1996)/conforming to iec 60898 in existing board/ sheets including making connections with lugs, testing etc. as required. group 2 6 a to 32 a rating 2.17 p & f recessed/ surface mounting heavy duty horizontal type sheet steel distribution board phophatised/ powder painted complete with 100 amp copper copper bus bar, shorting link, neutral, earth link and din bar, conforming to is 13032 & is 8623 including making internal db termination with copper lux, testing etc. as reqd. . group 2 single door(single phase) 8 way 2.18 p & f strip fluorscent tube fitting fabricated from (crca sheet and finished with powder coating/stove enamelled non corrosive uv resist ep channel) complete with accessories(low loss copperchoke, starter, starter seat)/electronic choke with terminal block duely prewired with copper conducter including making connection, testing etc. as required(without tube)1x36 watts with occb. group 2 2.19 p & f fluorscent tube rod in existing fixtures as required, minimum 3 star rating,36/40 watts 2.20 p/i aying pvc insulated & pvc sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i of groups of approved make in ground as per is:1255 including excavation of 30cm x 75cm size trench, 25cm thick under layer of sand, iind class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size 6 sqmm, 4 core arm 2.21 p & f star rated double ball beari;ng capacitor start, aluminium body and blade ceiling fan with down rod upto 30 cm with 3x1.5 sqmm pvc insulated flexible copper conductor making connection testing etc as required.1200 mm sweep 3 star rated 2.22 p & f is:371 marked 6 amp sufface type celling rose inculuding making commection testing etc. grup 2 (e071400) 2.23 p & f isi marked 6 amp bakelite batten/ angle holder including making connextion testing etc as required 2.24 p & f 18 swg ms recessed fan box, hexagonal/round of size 130mm dia, depth 75 mm , 12mm dia rad fan hook with 100mm length extended on eeach side. gourp 1 2.25 p & f 18 swg sheet steel boxes duly finisded with two coats of red oxide and with earthing terminal of following sizes (nominal size) on surfacae or in recessed as required. 175 mmx 100 mmx60 mm 2.26 p & f paper phenolic resin bonded laminates confirming to is: 2036 1995 for boxes/frames including making holes for switches etc with brass screws washers/zink plated nut and bolts as required with 3mm thick 2.27 p & f socket size flush type 120/280 watt rotary 5 step fan regulator including making connection testing etc. as required. ...

Sarva Shiksha Abhiyan Authority - Rajasthan

29304143 civil work at gsss sangasar block ratangarh sl. no. item description 1 part a civil work 2 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means over areas ( exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan ) including disposal ofexcavated earth, lead upto 50m andlift upto 1.5 m , disposed earth to be levelled and neatly dressed:all kinds of soil 3 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. 1:4:8 ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size ) . 4 random rubble stone masonary for foundation and plinth in cement sand mortar above 30 cm. thick wall in :cement mortar 1:6 ( 1 cement:6 sand ) . 5 providing & laying chequered terrazzo tiles of approved make 22mm thick with marble chips of size upto 6mm, in floors, jointed with neat cement slurry mixed wit pigment to match the shade of tiles including rubbing and polishing complete in all respect as per specification, on 28mm thick bed of c.m. 1:4 :dark shade using ordinary cement. 6 providing and laying in position specified grade ofcement concrete forall rcc structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 ( 1 cement: 3 coarse sand ) and making good the joints and cost of plastizers ( as required ) excluding the cost of centering, shuttering and reinforcement. m20 grade nominal mix / design mix providing m 25 grade concrete by using min 410 kg of cement per cum instead ofm 20 grade design mix. 7 supply & stacking good earth at site complete including loading unloading & transporation etc. 8 brick work with clay flyash f.p.s. brick ( is 13757 1993 ) of class designation 75 in superstructureaboveplinth level upto floor five level in :cement mortar 1 : 6 ( 1 cement : 6 coarse sand ) 9 stone kharanja: random rubble dry stone kharanja under floor 10 half brick masnory with clay flyash f.p.s. brick ( is 13757 1993 ) of class designation 75 in superstructureaboveplinth level upto floor five level in :cement mortar 1 : 4 ( 1 cement : 4 coarse sand ) 11 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 ( 1 cement: 3 coarse sand ) and making good the joints and cost of plastizers ( as required ) excluding the cost of centering, shuttering and reinforcementfor walls ( any thickness ) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.m20 grade nominal mix / design mixproviding m 25 grade concrete by using min 410 kg of cement per cum instead ofm 20 grade design mix. 12 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 ( 1 cement: 3 coarse sand ) and making good the joints and cost of plastizers ( as required ) excluding the cost of centering, shuttering and reinforcementfor beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.m20 grade nominal mix / design mix 13 centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchorblocks, sills, chhajjas, lintel, beam, plinth beam etc. 14 centering and shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. 15 centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : columns, pillars, posts and struts etc. 16 providing and fabricating reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding ( including cost of binding wire ) all complete up to floor five level. thermo mechanically treated bars ( conforming of relevent is code ) 17 structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m ) , fixing in position and applying a priming coat of approved steel primer all complete. 40×40×5mm 3kg per rmt 18 providing and fixing m.s. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of engg. incharge but excluding cost of chowkhats: including two coats of anit corrosive red oxide primer paint extra for double leaf shutters. 19 providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section ( is 1038 1983 ) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 ( 1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size ) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :partly fixed and partly openable [ fixed area not to exceed 33% ] 20 supplying and fixing fixed wire gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150 mm distance.14 mesh x 24 gauge 21 guard bars:providing and fixing square bars or other flat welded to window, ventilatiors etc. 22 kota stone slab flooring 25 mm thick over 20 mm ( average ) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 ( 1 cement : 4 coarse sand ) for area of each slab from 2001 to 5000 sq.cm 23 kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average ) thick cement mortar 1:3 ( 1 cement 3 coarse sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete for area of each slab from 2001to 5000 sqcm 24 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 12mm thick. 25 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20mm thick. 26 plaster ( ceiling ) : 6 mm thick cement plaster to ceiling of mix1:3 ( 1cement : 3 fine sand ) 27 making grooves as per design in plaster 10mm to 20mm wide. 28 green board : plaster on new surface on wall in cement sand mortar 1:3 including racking of joints etc. complete fine finish :12mm thick 29 m15 grade nominal mix 1: 2: 4 ( 1 cement : 2 coarse sand : 4 graded stoneaggregate 40mm nominal size ) . 30 providing gola 75x75 mm in cement concrete 1:2:4 ( 1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge ) includingfinishing with cement mortar 1:3 ( 1 cement : 3 fine sand ) as per standard design : 31 providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete 32 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect. 33 finishing wall with water proofing cement paint of approved brand and manufacture and or required shadetogive an even shade including all scaffolding: new work ( two or more coats applied @ 3.84 kg / 10 sqm ) . 34 painting with synthetic enamel paint of approved brand and manufacture togive an even shade : two or more coats on new work 35 providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats, or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxideextra if square, rectangular hollow tubularsections are used 36 copping:m20 grade nominal mix1: 1.5: 3 ( 1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size ) . 37 p&f rigid pvc pipe ( is:4985 mark ) class ii / ( 4 kg. / cm2. ) approved quality / makeincluding joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia 38 p&f rigid pvc pipe fittings ( is: 4985 mark ) of approved quality / make including joining the pipe with solvent cement rubber ring and lubricant: bend 87 .5 110mm dia 39 pipe clip110 mm dia 40 providing and fixing granite stone slab mirror polished and machine edge cut in walls, pillars, steps, shelves, sills, counters. floors etc. laid on 12mm ( av. ) thick base of cement mortar 1:3 jointing with white cement mortar 1:2 ( 1 white cement: 2 marble dust ) with pigment to match the shade of the marble slab complete including grinding, rubbing and polishing of:above 3601 cm2 slabs 41 providing and fixing 20 mm thick precast terrazo tiles of approved make, with marble chips of size upto 6mm laid over roof with neat cement slurry mixed with pigment to match the shade of the tiles, including cutting , grinding rubbing with machinecomplete on 20 mm thick bed of cement sand mortar 1 : 4. 42 part b sanetarywork 43 p & f kitchen & lab. sink of approved make with c.i. brackets duly painted 40 mm c.p. waste coupling c.p. brass chain with rubber plug, 40 mm g.i. waste pipe up to floor level complete including cutting and making good the wall & floor. ( wvc lab sink ( i.s 2556 mark ) size 530 x430x180 mm ) 44 p & f chromium plated swan neck laboratory cock of approved quality / make: one way. 45 p & f bib cock ( is : 8931 mark ) superior quality of approved make.c.p. brass 400 gm, 15 mm nominal bore. 46 p & f ball cock ( is : 1703 mark ) with rod & p.v.c. ball complete.brass wt. 400 gm, 15 mm 47 p & f inlet connection ( angle valves ) superior quality of approved make c.p. intel connection 15 mmbrass ( is : 8931 ) 48 p & f 15 mm dia connection pipe of approved quality make pvc pipes with nuts 450 mm. 49 p & f full way valve ( is : 778 mark ) or wheel valve of approved make. gun metal 15 mm nominal bore. 50 p & f stop cock ( is:8931 mark ) , superior quality and of approved mark: brass 400 gm. 15 mm nominal bore 51 p & f pvc storage tank isi marked ( is: 12701 ) indicating the bis license no. of approved make with cover, 25mm dia 1 m long g.i. overflow pipe & 25 cm longwash out pipe with plug & socket including making connection etc. complete of approved design 500 litres capacity 52 p&f gi pipes ( external work ) with gi fittings excluding union ( si: 1239 mark ) including trenching and refilling each etc. 15 mm dia nominal bore b class 53 providing & fixing ist quality standard white, gray, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to is : 13753 and is: 15622 of size 300mm x 200mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of tile complete ( excluding the cost of cement plaster on walls and piller ) 54 part c electrical work 55 wiring of light point / fan point / exhaust fan point / call bell point as per pwd specification for electrical works with isi marked 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1kv grade ( is: 694 ) and 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked ( is:9537 p ii ) rigid steel conduit & its all accessories, round tiles, 18 swg g.i.box with earth terminal, 6 a switch, 3 pin ceiling rose / lamp holder / 3 point connector, 3.0 mm thick isi markedphenolic laminated sheet, pvc bushes, check nuts, al. alloy / cadmium plated iron screws 20 mm cup washers etc. all as per pre approved by engineer in charge, making connections, testing etc. complete as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessoriesrefer chapter e 04, e 05 & e 07 .for additional technical parameters of products / work, referannexure a attached with this bsr . 56 light point 57 short point ( up to 3 mtr. ) 58 medium point ( up to 6 mtr ) 59 long point ( up to 10 mtr ) 60 fan point 61 short point ( up to 3 mtr. ) 62 medium point ( up to 6 mtr ) 63 long point ( up to 10 mtr ) 64 wiring of 3 / 5 pin 6 amp. light plug point as per pwd specification for electrical works with isi marked 1.5 sq. mm nominal sizefr pvc insulated unsheathed flexible copper conductor 1.1 kv grade ( is:694 ) and 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked ( is:9537 p ii ) rigid steel conduit & its all accessories, required size 18 swg, g.i. box with earth terminal, 6 aswitch, 3 / 5 pin 6 a socket, 3.0 mm thick isi marked phenoliclaminated sheet, pvc bushes, check nuts, al. alloy / cadmium plated iron screws 20 mm cup washers etc. all as per pre approved by engineer in charge, making connections, testing etc. complete as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessoriesrefer chapter e 04, e 05 & e 07 .for additional technical parameters of products / work, referannexure a attached with this bsr . on board 65 s&f following sizes ( dia. ) of isi marked ( is:9537 p ii ) rigid steel conduit of apropriate thickness related to its dia as per pwd specification for electrical works along with accessories inrecessed using saddles, clamps, fasteners, pvc bushes, check nuts, screwas etc. as required includingcutting the wall and making good the same as required all as per pre approved by engineer in charge.for additional technical parameters of products / work, referannexure a attached with this bsr . 25 mm 66 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from99.99% purity copper, class 5 stranding in acc. to iec 60228 forlower watt loss , oxygen free ( <10 ppm ) for less chances of oxidization and higher silver content for gives better conductivity , insulation pvc type a , flame retardant as per is 10810 53, better amperage rating as per vde 0298 part 4, , in existingsurface or recessed pvc / ms conduit / casing capping includingall as per pre approved by engineer in charge, making connections, etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of products / work, referannexure a attached with this bsr . 67 1 x 1.5 sq. mm 68 2 x 1.5 sq. mm 69 2 x 2.5 sq. mm 70 providing & fixing of 240 / 415 v ac mcb with positive isolation of breaking capacity not less than 10 ka ( b / c tripping characteristic as per type of load andsite requirement ) 4kv impulse withstand voltage, as per pwd specification for electrical works with isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , ip 20 contact protection and fitted withexisting distribution board / sheets, min. operation 20, 000 upto 32 a rating and 10, 000 upto 63 a, 5000 for 80 a ratingincluding making connections, testing etc. as required.. oem shall have submitnabl / cpri / erda accrediated lab test reportsbefore execution & all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 6 a to 32 a rating 71 providing & fixing of ik09 recessed / surface mounting heavy duty horizontal type sheet steel of 1.6 mm thickdistribution board as per pwd specificationfor electrical works isi marked conforming to is 13032 & is 8623 / conforming to iec 61439 3. phosphatised / powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link , connecting wire of suitable rating and din bar, masking sheet, including making internal dbterminations with copper lugs and with detachable gland plate, including making connections, testing etc. as required.oem shall have submitnabl / cpri / erda accrediated lab test reportsbefore execution & all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . ip 43 double door ( single phase ) 8 way ( 8 o / g +2 i / c ) 72 providing & fixing of ip40 led recessed / surface mounted, round / sqaure non dimmable back lit smd mid power led downlight with die cast aluminum housing & heat sink for heat dissipation with uv stabilized non yellowish diffuser with internal / external bis complience 2.5 kv surge protected isolated driver, with short & open circuit protection, having efficiency > 85% and in compliance to iec standards. system lumen efficacy of = 120 lm / watt, thd < 10 % , p.f.=0.95, cri >80, life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 / lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge . foe additional technical parameters of product / work, refer annexure a attacheded with this bsr.surface mountingled downlight 18 / 20w 73 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed un armoured / armoured copper cable of 1.1 kv grade as per pwd specification for electrical worksin existing rcc / hume / stoneware / pvc pipe / open duct / cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points ( a ) , ( b ) , ( c ) , mentioned below: ( a ) copper conductor of electrlytic grade copper, purity >99.97 % isi marked as peris:1554 p i / is :7098 p i 6.0 sq. mm 4 core 74 providing & fixing of iso certified company made beestar rated copper wounded double ball bearing capacitor start, aluminium body & metallicblade ceilingfanas per pwd specification for electrical works, conforming to is:374 2019, & is:1885 p v 1981. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required.appropriate oem test certificate shall be submitted by contractor. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 1200 mm sweep bee 3 star rated ( service value >=5.0 to< 5.5 ) 75 providing & fixing ofisi marked ( is:371 ) 6 amp surface type 3 pin ceiling roses as per pwd specification for electrical works, made out from industrial grade polycarbonate or fire resistant abs material, brass terminal & captive screws including making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 76 providing & fixing of isi marked ( is:1258 ) 6 ampbatten / angle lampholder as per pwd specification for electrical works, made out from industrial grade polycarbonate or fire resistant abs material, brass terminal & captive screws including making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 77 p & f 18 swgm.s. recessed fan box, hexagonal / round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mmlength extended on each side . all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 78 providing & fixing of 18 swg g. i. / m .s. sheet boxesas per pwd specification for electrical works, duly finished with two coats of red oxide and with earthing terminal of following sizes ( nominal size ) in recessed / surface as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr .175mm x 100mm x 60mm 18 swg m. s. sheet boxes 79 providing & fixing of paper phenolic resin bondedlaminates confirming to is : 2036 1995 for boxes / frames including making holes for switches etc, with brass / zinc plated screws, washers, nut and bolts as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 3.0 mm thick 80 providing & fixing of modular type step fan regulator duly isi marked ( is :11037 ) as per pwd specification for electrical works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , minimum width of 1 module switch toggle ( push part ) should not less then 20mm, includingall as per pre approved by engineer in charge, making connections, testing etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 5 step fan regulator 100 watt 2 module 81 p & f socket size flush type 120 / 280 watt rotary 5 step fan regulator including making connection testing etc. as required....

Sarva Shiksha Abhiyan Authority - Rajasthan

28964884 civil work at govt teliyan sec school sujangarh part a civil work 2 earth work in excavation by mechanical means (hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal ofexcavated earth, lead upto 50m andlift upto 1.5 m , disposed earth to be levelled and neatly dressed:all kinds of soil 3 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). 4 random rubble stone masonary for foundation and plinth in cement sand mortar above 30 cm. thick wall in :cement mortar 1:6 (1 cement:6 sand). 5 providing & laying chequered terrazzo tiles of approved make 22mm thick with marble chips of size upto 6mm, in floors, jointed with neat cement slurry mixed wit pigment to match the shade of tiles including rubbing and polishing complete in all respect as per specification, on 28mm thick bed of c.m. 1:4 :dark shade using ordinary cement. 6 providing and laying in position specified grade ofcement concrete forall rcc structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( as required) excluding the cost of centering, shuttering and reinforcement. m20 grade nominal mix / design mix providing m 25 grade concrete by using min 410 kg of cement per cum instead ofm 20 grade design mix. 7 supply & stacking good earth at site complete including loading unloading & transporation etc. 8 brick work with clay flyash f.p.s. brick(is 13757 1993 ) of class designation 75 in superstructureaboveplinth level upto floor five level in :cement mortar 1 : 6 (1 cement : 6 coarse sand) 9 half brick masnory with clay flyash f.p.s. brick(is 13757 1993 ) of class designation 75 in superstructureaboveplinth level upto floor five level in :cement mortar 1 : 4 (1 cement : 4 coarse sand) 10 stone kharanja: random rubble dry stone kharanja under floor 11 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (as required ) excluding the cost of centering, shuttering and reinforcementfor walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.m20 grade nominal mix / design mixproviding m 25 grade concrete by using min 410 kg of cement per cum instead ofm 20 grade design mix. 12 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( as required) excluding the cost of centering, shuttering and reinforcementfor beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.m20 grade nominal mix / design mix 13 centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 14 centering and shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 15 centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : columns, pillars, posts and struts etc. 16 providing and fabricating reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. thermo mechanically treated bars (conforming of relevent is code) 17 structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. 40×40×5mm 3kg per rmt 18 providing and fixing m.s. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of engg. incharge but excluding cost of chowkhats: including two coats of anit corrosive red oxide primer paint extra for double leaf shutters. 19 providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (is 1038 1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :partly fixed and partly openable [ fixed area not to exceed 33%] 20 supplying and fixing fixed wire gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150 mm distance.14 mesh x 24 gauge 21 guard bars:providing and fixing square bars or other flat welded to window, ventilatiors etc. 22 kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) for area of each slab from 2001 to 5000 sq.cm 23 kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete for area of each slab from 2001to 5000 sqcm 24 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 12mm thick. 25 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20mm thick. 26 plaster(ceiling): 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3 fine sand) 27 providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete 28 making grooves as per design in plaster 10mm to 20mm wide. 29 green board : plaster on new surface on wall in cement sand mortar 1:3 including racking of joints etc. complete fine finish :12mm thick 30 m15 grade nominal mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 40mm nominal size). 31 providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 32 distempering with 1st quality acrylic washable distemper (ready mixed) of approved manufacturer and of required shade and colour completeincluding all scaffolding as per manufacturers specification. two or more coats on new workincluding prepartion of base with primer, putty, lippy etc complete in all respect.applying one coat of cement primer of approved brand and manufacture on wall surface including all scaffolding: 33 finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specificationsincluding primer coat and protecting coat roller finish av. thickness 400 to 500 microns. 34 painting with synthetic enamel paint of approved brand and manufacture togive an even shade : two or more coats on new work 35 providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxideextra if square,rectangular hollow tubularsections are used 36 copping:m20 grade nominal mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size). 37 p&f rigid pvc pipe (is:4985 mark) class ii/ (4 kg. /cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia 38 p&f rigid pvc pipe fittings (is: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: bend 87 .5 110mm dia 39 pipe clip110 mm dia 40 providing and fixing 20 mm thick precast terrazo tiles of approved make, with marble chips of size upto 6mm laid over roof with neat cement slurry mixed with pigment to match the shade of the tiles, including cutting ,grinding rubbing with machinecomplete on 20 mm thick bed of cement sand mortar 1 : 4. 41 provinding and fixing3 layer pp r (polyproylene random copolymer) pipes sdr 7.4 uv stabilized & antimicrobial fusion welded, having thermal stability for hot and cold water supply including all pp r plain and brass threaded polypropylene random fittings and fixing the pipe with clamps at 1.00 spacing. this includes testing of joint complete as per direction of engineer incharge.(internal work exposed on wall)pn 16 pipe, 25 mm od 42 provinding and fixing3 layer pp r (polyproylene random copolymer) pipes sdr 7.4 uv stabilized & antimicrobial fusion welded, having thermal stability for hot and cold water supply including all pp r plain and brass threaded polypropylene random fittings and fixing the pipe with clamps at 1.00 spacing. this includes testing of joint complete as per direction of engineer incharge.(internal work exposed on wall)pn 16 pipe, 16 mm od 43 p & f squatting pan ( indian type ) white glaze viterous china 1st quality w.c. pan ( is: 2556 mark) with 100 mm viterous chinap or s trap including cutting & making good the wall & loor (excluding a pair of foot rest ) size 510 mm 44 p & f wvc wash basin (1st quality, i.s. : 2556 mark) of approved make with c.i. brackets duly painted, 1 no. 15 mm c.p. pillar cock (is : 8934 mark) & 32 mm c.p. brass waste coupling of approved make,25 mm g.i. waste pipe complete including cutting & making good the wall.: 450 x 300 mm 45 p & f bib cock (is : 8931 mark) superior quality of approved make.c.p. brass 400 gm, 15 mm nominal bore. 46 p&f rigid pvc pipe (is:4985 mark) class ii/ (4 kg. /cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia 47 p& f waste coulping with fittings of approved quality /make:c.p. brass 40 mm dia 48 p&f rigid pvc pipe fittings (is: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: bend 87.5110mm dia 49 pipe clip110 mm dia 50 p&f rigid pvc pipe fittings (is: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant plain floor trap 110 mm dia 51 p&f rigid pvc pipe fittings (is: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant p trap 110 mm dia 52 p&f rigid pvc pipe fittings (is: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant vent cowel 110 mm dia 53 p & f wvc( is :2556 mark)squatting urinalof standard make complete including cutting & making good the floorsize 450 x 350mm 54 s/f rccmain hole covers with frame of approved make (light duty) size 450x450 mm 55 p/f grating of approved quality stainiese steet sheet size 125 mm dia 56 construction of soakage well in alltypes of soil of approved drawing , top 90 cm portion in 450 mm thick with cement mortar 1:6 80 mm stone slab coveringjointing of slab in cm 1 : 3, ralthal, kharanja, 40 mm thick m 15 grade c.c. flooring earthwork etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr.inner dia 90 cm & 10 to 12 m deep 57 construction of chamber in all types of soil with 300 mm thick masnory in cm. 1 : 6, 100 mm thick c.c. 1 : 5 : 10 in foundation , 20 mm thick inside plaster in cm 1 : 6, finished with floating neat cement 50 mm thick m 15 grade c.c. flooring earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr.inside size 300 x 300 mm depth upto 0.5 m & 5 kg ci cover with frame. 58 p & f ball cock (is : 1703 mark) with rod & p.v.c. ball complete.brass wt. 400 gm, 15 mm 59 p & f 15 mm dia connection pipe of approved quality make pvc pipes with nuts 450 mm. 60 p & f full way valve (is : 778 mark) or wheel valve of approved make. gun metal 15 mm nominal bore. 61 p & f stop cock (is:8931 mark),superior quality and of approved mark: brass 400 gm. 15 mm nominal bore 62 p&f gi pipes (external work) with gi fittings excluding union (si: 1239 mark) including trenching and refilling each etc. 15 mm dia nominal bore b class 63 p & f pvc storage tank isi marked ( is: 12701) indicating the bis license no. of approved make with cover, 25mm dia 1 m long g.i. overflow pipe & 25 cm longwash out pipe with plug & socket including making connection etc. complete of approved design 500 litres capacity 64 part c electrical work 65 wiring of light point/fan point/exhaust fan point/ call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvcinsulated unsheathed flexible copper earth conductor 1.1 kv grade (is: 694) of approved make group 2 66 light point 67 short point (up to 3 mtr.) 68 medium point (up to 6 mtr) 69 long point (up to 10 mtr) 70 fan point 71 short point (up to 3 mtr.) 72 medium point (up to 6 mtr) 73 long point (up to 10 mtr) 74 wiring of 3 pin 5 amp. light plug point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvcinsulated unsheathed flexible copper earth conductor 1.1 kv grade (is: 694) of approved make in surface/reces group on board 75 s & f follwing sizes (dia.) of isi marked medium duty pvc conduit along with accessories in surface/ recessed using clamps, fastener as required including cutting the wall , covering conduit with wire mess and making good the same as required. group 225 mm dia 76 supplying and drawi;ng fr pvc insulated & unsheathed flexible copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existing surface ofr necessed conduit/ casting capping including making connections etc. as required. group 2 77 1 x 1.5 sq. mm 78 2 x 1.5 sq. mm 79 2 x 2.5 sq. mm 80 p & f 240/415 v mcb of breaking capacity not less than 10 ka (b/c/d tripping characteristic) isi marked is 8828 (1996)/conforming to iec 60898 in existing board/ sheets including making connections with lugs, testing etc. as required. group 2 6 a to 32 a rating 81 p & f recessed/ surface mounting heavy duty horizontal type sheet steel distribution board phophatised/ powder painted complete with 100 amp copper copper bus bar, shorting link, neutral, earth link and din bar, conforming to is 13032 & is 8623 including making internal db termination with copper lux, testing etc. as reqd. . group 2single door(single phase) 8 way 82 p & f strip fluorscent tube fitting fabricated from (crca sheet and finished with powder coating/stove enamelled non corrosive uv resist ep channel)complete with accessories(low loss copperchoke, starter, starter seat)/electronic choke with terminal block duely prewired with copper conducter including making connection, testing etc. as required(without tube)1x36 watts with occb. group 2 83 p & f fluorscent tube rod in existing fixtures as required, minimum 3 star rating,36/40 watts 84 p/i aying pvc insulated & pvc sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i of groups of approved make in ground as per is:1255 including excavation of 30cm x 75cm size trench, 25cm thick under layer of sand, iind class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size 6 sqmm, 4 core arm 85 p & f star rated double ball beari;ng capacitor start, aluminium bodyand blade ceiling fan with down rod upto 30 cm with 3x1.5 sqmm pvc insulated flexible copper conductor making connection testing etc as required.1200 mm sweep 3 star rated 86 p & f is:371 marked 6 amp suffacetype celling roseinculuding making commection testing etc. grup 2 (e071400) 87 p & f isi marked 6 amp bakelite batten/ angle holder including making connextion testing etc as required 88 p & f 18 swg ms recessed fan box, hexagonal/round of size 130mm dia, depth 75 mm , 12mm dia rad fan hookwith 100mm length extended on eeach side. gourp 1 89 p & f 18 swg sheet steel boxes duly finisded with two coats of red oxide and with earthing terminal of following sizes (nominal size) on surfacae or in recessed as required. 175 mmx 100 mmx60 mm 90 p & f paper phenolic resin bonded laminates confirming to is: 2036 1995 for boxes/frames including making holes for switches etc with brass screws washers/zink plated nut and bolts as required with 3mm thick 91 p & f socket size flush type 120/280 watt rotary 5 step fan regulator including making connection testing etc. as required. 92 p & f socket size flush type 120/280 watt rotary 5 step fan regulator including making connection testing etc. as required. ...

Sarva Shiksha Abhiyan Authority - Rajasthan

28964864 civil work at ggups van vihar churu civil work at ggups van vihar churu earth work in excavation by mechanical means (hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal ofexcavated earth, lead upto 50m andlift upto 1.5 m , disposed earth to be levelled and neatly dressed:all kinds of soil 3 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). 4 random rubble stone masonary for foundation and plinth in cement sand mortar above 30 cm. thick wall in :cement mortar 1:6 (1 cement:6 sand). 5 providing & laying chequered terrazzo tiles of approved make 22mm thick with marble chips of size upto 6mm, in floors, jointed with neat cement slurry mixed wit pigment to match the shade of tiles including rubbing and polishing complete in all respect as per specification, on 28mm thick bed of c.m. 1:4 :dark shade using ordinary cement. 6 providing and laying in position specified grade ofcement concrete forall rcc structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( as required) excluding the cost of centering, shuttering and reinforcement. m20 grade nominal mix / design mix providing m 25 grade concrete by using min 410 kg of cement per cum instead ofm 20 grade design mix. 7 supply & stacking good earth at site complete including loading unloading & transporation etc. 8 brick work with clay flyash f.p.s. brick(is 13757 1993 ) of class designation 75 in superstructureaboveplinth level upto floor five level in :cement mortar 1 : 6 (1 cement : 6 coarse sand) 9 stone kharanja: random rubble dry stone kharanja under floor 10 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (as required ) excluding the cost of centering, shuttering and reinforcementfor walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.m20 grade nominal mix / design mixproviding m 25 grade concrete by using min 410 kg of cement per cum instead ofm 20 grade design mix. 11 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( as required) excluding the cost of centering, shuttering and reinforcementfor beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.m20 grade nominal mix / design mix 12 centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 13 centering and shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 14 centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : columns, pillars, posts and struts etc. 15 providing and fabricating reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. thermo mechanically treated bars (conforming of relevent is code) 16 structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. 40×40×5mm 3kg per rmt 17 providing and fixing m.s. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of engg. incharge but excluding cost of chowkhats: including two coats of anit corrosive red oxide primer paint extra for double leaf shutters. 18 providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (is 1038 1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :partly fixed and partly openable [ fixed area not to exceed 33%] 19 supplying and fixing fixed wire gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150 mm distance.14 mesh x 24 gauge 20 guard bars:providing and fixing square bars or other flat welded to window, ventilatiors etc. 21 kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) for area of each slab from 2001 to 5000 sq.cm 22 kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete for area of each slab from 2001to 5000 sqcm 23 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 12mm thick. 24 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20mm thick. 25 plaster(ceiling): 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3 fine sand) 26 providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete 27 making grooves as per design in plaster 10mm to 20mm wide. 28 green board : plaster on new surface on wall in cement sand mortar 1:3 including racking of joints etc. complete fine finish :12mm thick 29 m15 grade nominal mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 40mm nominal size). 30 providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 31 distempering with 1st quality acrylic washable distemper (ready mixed) of approved manufacturer and of required shade and colour completeincluding all scaffolding as per manufacturers specification. two or more coats on new workincluding prepartion of base with primer, putty, lippy etc complete in all respect.applying one coat of cement primer of approved brand and manufacture on wall surface including all scaffolding: 32 finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specificationsincluding primer coat and protecting coat roller finish av. thickness 400 to 500 microns. 33 painting with synthetic enamel paint of approved brand and manufacture togive an even shade : two or more coats on new work 34 providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxideextra if square,rectangular hollow tubularsections are used 35 copping:m20 grade nominal mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size). 36 p&f rigid pvc pipe (is:4985 mark) class ii/ (4 kg. /cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia 37 p&f rigid pvc pipe fittings (is: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: bend 87 .5 110mm dia 38 pipe clip110 mm dia 39 providing and fixing 20 mm thick precast terrazo tiles of approved make, with marble chips of size upto 6mm laid over roof with neat cement slurry mixed with pigment to match the shade of the tiles, including cutting ,grinding rubbing with machinecomplete on 20 mm thick bed of cement sand mortar 1 : 4. 40 part c electrical work 41 wiring of light point/fan point/exhaust fan point/ call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvcinsulated unsheathed flexible copper earth conductor 1.1 kv grade (is: 694) of approved make group 2 42 light point 43 short point (up to 3 mtr.) 44 medium point (up to 6 mtr) 45 long point (up to 10 mtr) 46 fan point 47 short point (up to 3 mtr.) 48 medium point (up to 6 mtr) 49 long point (up to 10 mtr) 50 wiring of 3 pin 5 amp. light plug point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvcinsulated unsheathed flexible copper earth conductor 1.1 kv grade (is: 694) of approved make in surface/reces group on board 51 s & f follwing sizes (dia.) of isi marked medium duty pvc conduit along with accessories in surface/ recessed using clamps, fastener as required including cutting the wall , covering conduit with wire mess and making good the same as required. group 225 mm dia 52 supplying and drawi;ng fr pvc insulated & unsheathed flexible copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existing surface ofr necessed conduit/ casting capping including making connections etc. as required. group 2 53 1 x 1.5 sq. mm 54 2 x 1.5 sq. mm 55 2 x 2.5 sq. mm 56 p & f 240/415 v mcb of breaking capacity not less than 10 ka (b/c/d tripping characteristic) isi marked is 8828 (1996)/conforming to iec 60898 in existing board/ sheets including making connections with lugs, testing etc. as required. group 2 6 a to 32 a rating 57 p & f recessed/ surface mounting heavy duty horizontal type sheet steel distribution board phophatised/ powder painted complete with 100 amp copper copper bus bar, shorting link, neutral, earth link and din bar, conforming to is 13032 & is 8623 including making internal db termination with copper lux, testing etc. as reqd. . group 2single door(single phase) 8 way 58 p & f strip fluorscent tube fitting fabricated from (crca sheet and finished with powder coating/stove enamelled non corrosive uv resist ep channel)complete with accessories(low loss copperchoke, starter, starter seat)/electronic choke with terminal block duely prewired with copper conducter including making connection, testing etc. as required(without tube)1x36 watts with occb. group 2 59 p & f fluorscent tube rod in existing fixtures as required, minimum 3 star rating,36/40 watts 60 p/i aying pvc insulated & pvc sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i of groups of approved make in ground as per is:1255 including excavation of 30cm x 75cm size trench, 25cm thick under layer of sand, iind class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size 6 sqmm, 4 core arm 61 p & f star rated double ball beari;ng capacitor start, aluminium bodyand blade ceiling fan with down rod upto 30 cm with 3x1.5 sqmm pvc insulated flexible copper conductor making connection testing etc as required.1200 mm sweep 3 star rated 62 p & f is:371 marked 6 amp suffacetype celling roseinculuding making commection testing etc. grup 2 (e071400) 63 p & f isi marked 6 amp bakelite batten/ angle holder including making connextion testing etc as required 64 p & f 18 swg ms recessed fan box, hexagonal/round of size 130mm dia, depth 75 mm , 12mm dia rad fan hookwith 100mm length extended on eeach side. gourp 1 65 p & f 18 swg sheet steel boxes duly finisded with two coats of red oxide and with earthing terminal of following sizes (nominal size) on surfacae or in recessed as required. 175 mmx 100 mmx60 mm 66 p & f paper phenolic resin bonded laminates confirming to is: 2036 1995 for boxes/frames including making holes for switches etc with brass screws washers/zink plated nut and bolts as required with 3mm thick 67 p & f socket size flush type 120/280 watt rotary 5 step fan regulator including making connection testing etc. as required. 68 p & f socket size flush type 120/280 watt rotary 5 step fan regulator including making connection testing etc. as required. ...

Sarva Shiksha Abhiyan Authority - Rajasthan

28964862 civil work at gups khemka churu civil work at gups khemka churu part a civil work 2 earth work in excavation by mechanical means (hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal ofexcavated earth, lead upto 50m andlift upto 1.5 m , disposed earth to be levelled and neatly dressed:all kinds of soil 3 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). 4 random rubble stone masonary for foundation and plinth in cement sand mortar above 30 cm. thick wall in :cement mortar 1:6 (1 cement:6 sand). 5 providing & laying chequered terrazzo tiles of approved make 22mm thick with marble chips of size upto 6mm, in floors, jointed with neat cement slurry mixed wit pigment to match the shade of tiles including rubbing and polishing complete in all respect as per specification, on 28mm thick bed of c.m. 1:4 :dark shade using ordinary cement. 6 providing and laying in position specified grade ofcement concrete forall rcc structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( as required) excluding the cost of centering, shuttering and reinforcement. m20 grade nominal mix / design mix providing m 25 grade concrete by using min 410 kg of cement per cum instead ofm 20 grade design mix. 7 supply & stacking good earth at site complete including loading unloading & transporation etc. 8 brick work with clay flyash f.p.s. brick(is 13757 1993 ) of class designation 75 in superstructureaboveplinth level upto floor five level in :cement mortar 1 : 6 (1 cement : 6 coarse sand) 9 half brick masnory with clay flyash f.p.s. brick(is 13757 1993 ) of class designation 75 in superstructureaboveplinth level upto floor five level in :cement mortar 1 : 4 (1 cement : 4 coarse sand) 10 stone kharanja: random rubble dry stone kharanja under floor 11 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (as required ) excluding the cost of centering, shuttering and reinforcementfor walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.m20 grade nominal mix / design mixproviding m 25 grade concrete by using min 410 kg of cement per cum instead ofm 20 grade design mix. 12 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( as required) excluding the cost of centering, shuttering and reinforcementfor beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.m20 grade nominal mix / design mix 13 centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 14 centering and shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 15 centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : columns, pillars, posts and struts etc. 16 providing and fabricating reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. thermo mechanically treated bars (conforming of relevent is code) 17 structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. 40×40×5mm 3kg per rmt 18 providing and fixing m.s. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of engg. incharge but excluding cost of chowkhats: including two coats of anit corrosive red oxide primer paint extra for double leaf shutters. 19 providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (is 1038 1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :partly fixed and partly openable [ fixed area not to exceed 33%] 20 supplying and fixing fixed wire gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150 mm distance.14 mesh x 24 gauge 21 guard bars:providing and fixing square bars or other flat welded to window, ventilatiors etc. 22 kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) for area of each slab from 2001 to 5000 sq.cm 23 kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete for area of each slab from 2001to 5000 sqcm 24 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 12mm thick. 25 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20mm thick. 26 plaster(ceiling): 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3 fine sand) 27 providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete 28 making grooves as per design in plaster 10mm to 20mm wide. 29 green board : plaster on new surface on wall in cement sand mortar 1:3 including racking of joints etc. complete fine finish :12mm thick 30 m15 grade nominal mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 40mm nominal size). 31 providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 32 distempering with 1st quality acrylic washable distemper (ready mixed) of approved manufacturer and of required shade and colour completeincluding all scaffolding as per manufacturers specification..two or more coats on new workincluding prepartion of base with primer, putty, lippy etc complete in all respect.applying one coat of cement primer of approved brand and manufacture on wall surface including all scaffolding: 33 finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specificationsincluding primer coat and protecting coat roller finish av. thickness 400 to 500 microns. 34 painting with synthetic enamel paint of approved brand and manufacture togive an even shade : two or more coats on new work 35 providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxideextra if square,rectangular hollow tubularsections are used 36 copping:m20 grade nominal mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size). 37 p&f rigid pvc pipe (is:4985 mark) class ii/ (4 kg. /cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia 38 p&f rigid pvc pipe fittings (is: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: bend 87 .5 110mm dia 39 pipe clip110 mm dia 40 providing and fixing 20 mm thick precast terrazo tiles of approved make, with marble chips of size upto 6mm laid over roof with neat cement slurry mixed with pigment to match the shade of the tiles, including cutting ,grinding rubbing with machinecomplete on 20 mm thick bed of cement sand mortar 1 : 4. 41 supply & fixing of stainless steel pipe railing for ramp / staircaserailing height, 90 cm. with 50 mm dia stainless steel pipe with 18 gauge with drop (vertical post) at 90 cm. c/c and intermidiate3 nos 20 mm dia horizontal pipe with suitable height of same gauge with coupling, grinding and polishing & fix of master pieces as per required point as per approved design of engineer incharge 42 provinding and fixing3 layer pp r (polyproylene random copolymer) pipes sdr 7.4 uv stabilized & antimicrobial fusion welded, having thermal stability for hot and cold water supply including all pp r plain and brass threaded polypropylene random fittings and fixing the pipe with clamps at 1.00 spacing. this includes testing of joint complete as per direction of engineer incharge.(internal work exposed on wall)pn 16 pipe, 25 mm od 43 provinding and fixing3 layer pp r (polyproylene random copolymer) pipes sdr 7.4 uv stabilized & antimicrobial fusion welded, having thermal stability for hot and cold water supply including all pp r plain and brass threaded polypropylene random fittings and fixing the pipe with clamps at 1.00 spacing. this includes testing of joint complete as per direction of engineer incharge.(internal work exposed on wall)pn 16 pipe, 16 mm od 44 p & f squatting pan ( indian type ) white glaze viterous china 1st quality w.c. pan ( is: 2556 mark) with 100 mm viterous chinap or s trap including cutting & making good the wall & loor (excluding a pair of foot rest ) size 510 mm 45 p & f wvc wash basin (1st quality, i.s. : 2556 mark) of approved make with c.i. brackets duly painted, 1 no. 15 mm c.p. pillar cock (is : 8934 mark) & 32 mm c.p. brass waste coupling of approved make,25 mm g.i. waste pipe complete including cutting & making good the wall.: 450 x 300 mm 46 p & f bib cock (is : 8931 mark) superior quality of approved make.c.p. brass 400 gm, 15 mm nominal bore. 47 p&f rigid pvc pipe (is:4985 mark) class ii/ (4 kg. /cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia 48 p& f waste coulping with fittings of approved quality /make:c.p. brass 40 mm dia 49 p&f rigid pvc pipe fittings (is: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: bend 87.5110mm dia 50 pipe clip110 mm dia 51 p&f rigid pvc pipe fittings (is: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant plain floor trap 110 mm dia 52 p&f rigid pvc pipe fittings (is: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant p trap 110 mm dia 53 p&f rigid pvc pipe fittings (is: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant vent cowel 110 mm dia 54 p & f wvc( is :2556 mark)squatting urinalof standard make complete including cutting & making good the floorsize 450 x 350mm 55 s/f rccmain hole covers with frame of approved make (light duty) size 450x450 mm 56 p/f grating of approved quality stainiese steet sheet size 125 mm dia 57 construction of soakage well in alltypes of soil of approved drawing , top 90 cm portion in 450 mm thick with cement mortar 1:6 80 mm stone slab coveringjointing of slab in cm 1 : 3, ralthal, kharanja, 40 mm thick m 15 grade c.c. flooring earthwork etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr.inner dia 90 cm & 10 to 12 m deep 58 construction of chamber in all types of soil with 300 mm thick masnory in cm. 1 : 6, 100 mm thick c.c. 1 : 5 : 10 in foundation , 20 mm thick inside plaster in cm 1 : 6, finished with floating neat cement 50 mm thick m 15 grade c.c. flooring earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr.inside size 300 x 300 mm depth upto 0.5 m & 5 kg ci cover with frame. 59 p & f ball cock (is : 1703 mark) with rod & p.v.c. ball complete.brass wt. 400 gm, 15 mm 60 p & f 15 mm dia connection pipe of approved quality make pvc pipes with nuts 450 mm. 61 p & f full way valve (is : 778 mark) or wheel valve of approved make. gun metal 15 mm nominal bore. 62 p & f stop cock (is:8931 mark),superior quality and of approved mark: brass 400 gm. 15 mm nominal bore 63 p&f gi pipes (external work) with gi fittings excluding union (si: 1239 mark) including trenching and refilling each etc. 15 mm dia nominal bore b class 64 p & f pvc storage tank isi marked ( is: 12701) indicating the bis license no. of approved make with cover, 25mm dia 1 m long g.i. overflow pipe & 25 cm longwash out pipe with plug & socket including making connection etc. complete of approved design 500 litres capacity 65 part c electrical work 66 wiring of light point/fan point/exhaust fan point/ call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvcinsulated unsheathed flexible copper earth conductor 1.1 kv grade (is: 694) of approved make group 2 67 light point 68 short point (up to 3 mtr.) 69 medium point (up to 6 mtr) 70 long point (up to 10 mtr) 71 fan point 72 short point (up to 3 mtr.) 73 medium point (up to 6 mtr) 74 long point (up to 10 mtr) 75 wiring of 3 pin 5 amp. light plug point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvcinsulated unsheathed flexible copper earth conductor 1.1 kv grade (is: 694) of approved make in surface/reces group on board 76 s & f follwing sizes (dia.) of isi marked medium duty pvc conduit along with accessories in surface/ recessed using clamps, fastener as required including cutting the wall , covering conduit with wire mess and making good the same as required. group 225 mm dia 77 supplying and drawi;ng fr pvc insulated & unsheathed flexible copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existing surface ofr necessed conduit/ casting capping including making connections etc. as required. group 2 78 1 x 1.5 sq. mm 79 2 x 1.5 sq. mm 80 2 x 2.5 sq. mm 81 p & f 240/415 v mcb of breaking capacity not less than 10 ka (b/c/d tripping characteristic) isi marked is 8828 (1996)/conforming to iec 60898 in existing board/ sheets including making connections with lugs, testing etc. as required. group 2 6 a to 32 a rating 82 p & f recessed/ surface mounting heavy duty horizontal type sheet steel distribution board phophatised/ powder painted complete with 100 amp copper copper bus bar, shorting link, neutral, earth link and din bar, conforming to is 13032 & is 8623 including making internal db termination with copper lux, testing etc. as reqd. . group 2single door(single phase) 8 way 83 p & f strip fluorscent tube fitting fabricated from (crca sheet and finished with powder coating/stove enamelled non corrosive uv resist ep channel)complete with accessories(low loss copperchoke, starter, starter seat)/electronic choke with terminal block duely prewired with copper conducter including making connection, testing etc. as required(without tube)1x36 watts with occb. group 2 84 p & f fluorscent tube rod in existing fixtures as required, minimum 3 star rating,36/40 watts 85 p/i aying pvc insulated & pvc sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i of groups of approved make in ground as per is:1255 including excavation of 30cm x 75cm size trench, 25cm thick under layer of sand, iind class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size 6 sqmm, 4 core arm 86 p & f star rated double ball beari;ng capacitor start, aluminium bodyand blade ceiling fan with down rod upto 30 cm with 3x1.5 sqmm pvc insulated flexible copper conductor making connection testing etc as required.1200 mm sweep 3 star rated 87 p & f is:371 marked 6 amp suffacetype celling roseinculuding making commection testing etc. grup 2 (e071400) 88 p & f isi marked 6 amp bakelite batten/ angle holder including making connextion testing etc as required 89 p & f 18 swg ms recessed fan box, hexagonal/round of size 130mm dia, depth 75 mm , 12mm dia rad fan hookwith 100mm length extended on eeach side. gourp 1 90 p & f 18 swg sheet steel boxes duly finisded with two coats of red oxide and with earthing terminal of following sizes (nominal size) on surfacae or in recessed as required. 175 mmx 100 mmx60 mm 91 p & f paper phenolic resin bonded laminates confirming to is: 2036 1995 for boxes/frames including making holes for switches etc with brass screws washers/zink plated nut and bolts as required with 3mm thick 92 p & f socket size flush type 120/280 watt rotary 5 step fan regulator including making connection testing etc. as required. 93 p & f socket size flush type 120/280 watt rotary 5 step fan regulator including making connection testing etc. as required. ...

Urban Improvement Trust - Rajasthan

28750125 supply of pumpset and related accessories in uit store 1 providing & fixing of hdpe pipe isi mark ( is:4984 / 95 ) for water supply ( suitable for submersible & jet pump ) with required fittings 40 mm od 6 kg / cm2 2 providing & fixing of hdpe pipe isi mark ( is:4984 / 95 ) for water supply ( suitable for submersible & jet pump ) with required fittings 50 mm od 6 kg / cm2 3 sitc of radial / mixed flow submersible motor pumpsets isi marked ( is:8034 1989 ) of approved makewith required accessories including makingconnection suitable for t.w. / d.c.b. / open well. thejob includes lowering of riser pipe, g.i. / h.d.p.e.pipe with rope, cables, installation of completefitting and accessories, jointing of electrical cablesup to switch board. all labour for testing ofsubmersible pumps set and supply of water to watermains, complete in all respect. 100 mm diameter submersible pump shall have following hp rating, phase, head, minimum discharge respectively. 2.0 hp, 1 ø, ( 45 89 ) mtr, ( 100 33 ) lpm 4 sitc of radial / mixed flow submersible motor pumpsets isi marked ( is:8034 1989 ) of approved makewith required accessories including makingconnection suitable for t.w. / d.c.b. / open well. thejob includes lowering of riser pipe, g.i. / h.d.p.e.pipe with rope, cables, installation of completefitting and accessories, jointing of electrical cablesup to switch board. all labour for testing ofsubmersible pumps set and supply of water to watermains, complete in all respect. 100 mm diameter submersible pump shall have following hp rating, phase, head, minimum discharge respectively.3.0 hp, 3 ø, ( 69 125 ) mtr, ( 110 33 ) lpm 5 sitc of radial / mixed flow submersible motor pumpsets isi marked ( is:8034 1989 ) of approved makewith required accessories including makingconnection suitable for t.w. / d.c.b. / open well. thejob includes lowering of riser pipe, g.i. / h.d.p.e.pipe with rope, cables, installation of completefitting and accessories, jointing of electrical cablesup to switch board. all labour for testing ofsubmersible pumps set and supply of water to watermains, complete in all respect. 100 mm diameter submersible pump shall have following hp rating, phase, head, minimum discharge respectively. 5.0 hp, 3 ø, ( 120 220 ) mtr, ( 100 38 ) lpm 6 supply and fixing of oil / air break starter panelmade out of sheet steel powder coated enclosurecomprising of over load protection relay, shortcircuit & single phasing protection, on / off pushbuttons, ammeter, voltmeter, indicating lamps etc.complete in all respect suitable for following ratingmotors.for single phase submersible / monoblock pump.0.5 hp to 3.0 hp 7 supply and fixing of oil / air break starter panelmade out of sheet steel powder coated enclosurecomprising of over load protection relay, shortcircuit & single phasing protection, on / off pushbuttons, ammeter, voltmeter, indicating lamps etc.complete in all respect suitable for following ratingmotors. for three phase submersible / mono block pump. 3.0 hp to 10.0 hp ( dol ) 8 providing of synthetic rope for submersible pump isimarked ( is:5175 ) of following sizes. 12mm ( suitable up to 50 mm od pipe ) 9 providing of synthetic rope for submersible pump isimarked ( is:5175 ) of following sizes. 16mm ( suitable above 50mm & up to 75mm od pipe ) 10 providing of synthetic rope for submersible pump isimarked ( is:5175 ) of following sizes. 20mm ( suitable for 90 mm od pipe ) 11 supplying and installation of 32mm dia gi pipe b class isi marked including all accessories and fittings required for installation of hand pump. ( prakash surya / tt swastic / jindal ) 12 p&f 240 / 415 v ac mcb with positiveisolation of breaking capacity not less than10 ka ( b / c / d tripping characteristic ) isimarked is 8828 ( 1996 ) ] / conforming to iec60898 in existing board / sheets includingmaking connections, testing etc. as required. double pole mcb 40 a 63 a rating 13 p&f 240 / 415 v ac mcb with positiveisolation of breaking capacity not less than10 ka ( b / c / d tripping characteristic ) isimarked is 8828 ( 1996 ) ] / conforming to iec60898 in existing board / sheets includingmaking connections, testing etc. as required. four pole mcb mcb 40 a 63 a rating 14 sf of ct operated direct reading type ampere meter onexisting panel , making connection by pvc insulatedcopper conductor with pvc sleeves / channel etc. asrequired. below 500 a 15 sf of ( 0 500 ) v range volt meter on existing panel , making connection by pvc insulated copper conductorwith pvc sleeves / channel etc. as required. digital type 16 p & f paper phenolic resin bonded laminatesconfirming to is : 2036 1995 for boxes / framesincluding making holes for switches etc, with brassscrews, washers / zinc plated nut and bolts as required. 6.4 mm thick 17 supplying and drawing fr pvc insulated &unsheathed flexible copper conductor isimarked ( is:694 ) of 1.1 kv grade andapproved make in existing surface orrecessed conduit / casing capping includingmaking connections etc. as required. 1 x 10.0 sq.mm...

Rajasthan Rajya Vidhyut Utpadan Nigam Limited - Rajasthan

23541639 requirement of lighting material hpsv lamps, ballast : vacuum pressure impregnated copper ballast suitable for hpsv lamp, electronic ignitor suitable, ip 65 protected integral wellglass luminaires suitable, ip 65 protected integral flood lighting luminaires suitable, fluorescent tubelight, 6 amp switch boards, led lights, electrical accessories 6a flush type switch, bell push/ one way switch, 6a twin control switch flush type, 3 pin 6 amp. flush type socket, 3/6 pin 16 amp. flush type socket, 16 amp. flush type switch, 6 amp.bekelite batten/angle holder, 6 amp. surface type ceiling rose, socket size flush type 120/180 watt rotary 5 step fan regulator, combined 6 pin, 16 amp switch and socket outlet, ding dong musical bell, flush/ surface type buzzer bell, isi marked 16 a bakelite unbreakable 3 pin plug top, isi marked 6 a bakelite unbreakable 3 pin plug top fr pvc insulated and unsheathed flexible copper conductor isi marked of 1.1 kv grade, paper phenolic resin bonded laminates for boxes / frames, capacitor 230 v /275 v 50 hz, 3 speed rotary switch for desert cooler, submersible pump for desert coolers, stem type snap action bipolar adjustable thermostat with built in auto thermal cut out of storage water heater, isi marked 4159 marked copper sheathed nickel plated mineral filled heating element, halogen tube lamps, pvc casing capping, isi marked medium duty pvc conduit, mounting grid plates with cover plates, hot dipped galvanised m. s. box of 20 swg, plastic/ porceline b22 e27 screw base socket lamp holder and light bulb adapter (white), energy saving helogen e27 edison screw cap bulb 70w. ...

Rajasthan Rajya Vidyut Utpadan Nigam Limited - Rajasthan

23522274 requirement of lighting material of ctpp, chhabra 1 hpsv lamps : hpsv elliptical lamp normal output high pressure sodium vapour lamp, 240 vac screw type of make group 1 of pwd bsr for electrical works 2013 of govt. of rajasthan 2 70 watt ( e ) 3 150 watt ( e ) 4 250 watt ( e ) 5 400 watt ( e ) 6 hpsv lamps : hpsv tubular lamp high output high pressure sodium vapour lamp, 240 vac screw type of make group 1 of pwd bsr for electrical works 2013 of govt. of rajasthan 7 250 watt ( t ) 8 400 watt ( t ) 9 1000 watt ( t ) 10 ballast : vacuum pressure impregnated copper ballast suitable for hpsv lamp luminaire, 240 vac of make group 1 of pwd bsr for electrical works 2013 of govt. of rajasthan 11 70 watt 12 150 watt 13 250 watt 14 400 watt 15 1000 watt 16 electronic ignitor suitable for hpsv lampmake group 1 of pwd bsr for electrical works 2013 of govt. of rajasthan 17 70 watt / 150 watt / 250 watt / 400 watt 18 ip 65 protected integral wellglass luminaires suitable for hpsv lamp comprising die cast aluminium housing epoxy grey powder coated built in control gearbox having hpsv lamp, copper ballast, capacitor, electronic ignitor, heat resistant wellglass with ms zinc plated wire guard and eyebolt.make group 1 of pwd bsr for electrical works 2013 of govt. of rajasthan 19 70 watt hpsv 20 150 watt hpsv 21 ip 65 protected integral flood lighting luminaires suitable for hpsv lamp comprising of black powder coated die cast aluminium housing, aluminium reflector, covered with suitably gasketed heat resistant toughened clear glass cover, integral control gear box having hpsv lamp, copper ballast, capacitor and electronic ignitor.make group 1 of pwd bsr for electrical works 2013 of govt. of rajasthan 22 1 x 250 w hpsv tubular 23 1 x 400 w hpsv tubular 24 fluorescent tubelight complete fitting with tubelight rod and electronic ballast, 240 vac make group 1 of pwd bsr for electrical works 2013 of govt. of rajasthan 25 1x36 / 40w ftl, length 1200 mm 26 2x36 / 40w ftl, length 1200 mm 27 6 amp switch boards ( modular type ) ( including switch, socket and accessories ) make group 1 of pwd bsr for electrical works 2013 of govt. of rajasthan nvoltage: 220 240 v ac 28 suaitable for 2 switch + 2 socket 29 suaitable for 4 switch + 4 sockets 30 16 amp power switch boards ( modular type ) ( including 1 switch, 1 socket and accessories ) make group 1 of pwd bsr for electrical works 2013 of govt. of rajasthan nvoltage: 220 240 v ac 31 16 amp ( suitable for 1 switch + 1 socket 32 led lights of make group 1 of pwd bsr for electrical works 2013 of govt. of rajasthan 33 90 watt complete led street light 34 150 watt flood lights 35 250 watt flood lights 36 350 watt flood lights 37 electrical accesories of make group 1 of pwd bsr for electrical works 2013 of govt. of rajasthan 38 6a flush type switch 39 bell push / one way switch 40 6a twin control switch flush type 41 3 pin 6 amp. flush type socket 42 3 / 6 pin 16 amp. flush type socket 43 16 amp. flush type switch 44 6 amp.bekelite batten / angle holder 45 6 amp. surface type ceiling rose 46 socket size flush type 120 / 180 watt rotary 5 step fan regulator 47 combined 6 pin, 16 amp switch and socket outlet 48 ding dong musical bell 49 flush / surface type buzzer bell 50 isi marked 16 a bakelite unbreakable 3 pin plug top 51 isi marked 6 a bakelite unbreakable 3 pin plug top 52 fr pvc insulated and unsheathed flexible copper conductor isi marked of 1.1 kv grade 53 1x1.5 sq. mm 54 1x2.5 sq. mm 55 1x4 sq. mm 56 1x6 sq. mm 57 paper phenolic resin bonded laminates for boxes / frames 58 3.00 mm thick ( in sq. mtr. ) 59 capacitor 230 v / 275 v 50 hz 60 4.0 mfd 61 2.5 / 3.15 mfd 62 3 speed rotary switch for desert cooler 63 high quality pvc distribution ‘t’ and 3 nos. pvc ½” elbow for cooler 64 submersible pump for desert coolers 65 stem type snap action bipolar adjustable thermostat with built in auto thermal cut out of storage water heater 66 isi marked 4159 marked copper sheathed nickel plated mineral filled heating element 67 3.0 kw 68 2.0 kw 69 halogen tube lamps 1000w 70 halogen tube lamps 500 w 71 following modular accessories 72 6a one way switch 73 6a 3 pin shuttered socket 74 16a one way switch 75 16a 6 pin shuttered socket 76 isi marked ( is: 14927 p ii ) pvc casing capping ( in mtrs ) 77 25 mm x 12 mm 78 20 mm x 12 mm 79 isi marked medium duty pvc conduit ( in mtrs ) 80 20 mm 81 25mm 82 following size mounting grid plates with cover plates 83 1 / 2 module 84 3 module 85 4 module 86 following size hot dipped galvanised m. s. box of 20 swg 87 1 / 2 module 88 4 module 89 9 w round b22 led bulb 90 plastic / porceline b22 e27 screw base socket lamp holder and light bulb adapter ( white ) 91 energy saving helogen e27 edison screw cap bulb 70w...

Jaipur Development Authority - Rajasthan

21966206 supply installation testing commissioning of various electrical equipment required for protection of system along with repair and maintenance of transformers installed at jawahar circle , central park and nehru park . 1 wiring of light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) of approved make in surface / recessed isi marked mms ( is:9537 p iii ) pvc conduit & its accessories, round tiles, 18 swg m.s. box with earth terminal, 6 a switch, 3.0 mm thick isi marked phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. 2 medium point ( up to 6 mtr. ) 3 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor isi marked ( is:694 ) of 1.1 kv grade and approved make in existing surface or recessed conduit / casing capping including making connections etc. as required. 4 2 x 1.5 sq.mm 5 supplying and fixing of power plug point accessories on 18 swg metal box of size 175 x 100 x 60 mm. on surface or in recessed with suitable size phenolic laminated sheet cover including cost of 6 pin 16 amp. switch and socket outlet , making connection , testing , etc. as required. 6 p & f in position frame made out of m.s. angle ( riveted or welded ) finished with two coats of red oxide and enamel paint including cutting, welding, holes etc.of following sizes as required. complete rate group 1 7 50mm x 50mm x 6mm 8 p & f paper phenolic resin bonded laminates confirming to is : 2036 1995 for boxes / frames including making holes for switches etc, with brass screws, washers / zinc plated nut and bolts as required. complete rate group 1 9 6.4 mm thick 10 p&f 240 / 415 v ac mcb with positive isolation of breaking capacity not less than 10 ka ( b / c / d tripping characteristic ) isi marked is 8828 ( 1996 ) ] / conforming to iec 60898 in existing board / sheets including making connections, testing etc. as required. 11 single pole mcb 12 6 a to 32 a rating 13 triple pole mcb 14 40 a 63 a rating 15 p&f 240 / 415 v isolator conforming to is:13947 iii / iec 60947 3 on existing board / sheet including making connections, testing etc. as required. 16 four pole isolator 17 100 a rating 18 p&f flush / surface type enclosure for housing mcb / isolator with din rail including making connections with lugs, repairs etc. as required. with sheet steel enclosure complete rate group 1 19 four way 20 p & f of industrial plug and socket conforming to iec 60309 1 / 2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. panel mounted socket. complete rate group 1 21 16 a 3 pin 22 sitc of wall / free standing floor mounted dust and vermin proof compartmentalised cubical panel made out of crca sheet , required hardware , duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panel in desired shade the panel having pu / neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate m.s. base channel , hinged door with locking arrangement for equipment / switchgear . thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. load bearing structure shall be of 2.0 mm thick sheet supported by base m.s. channel if required . side walls and cable alley compartments having bolted type doors with / without detachable extension type structure. ( only outer area on all sides shall be measured & panel to be fabricated from cpri approved fabricator ) . complete rate group 1 23 supplying and fixing of aluminium / copper bus bar by means of smc / dmc type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. complete rate group 1 24 electrolytic grade copper bus bar 25 sf of ( 0 500 ) v range volt meter on existing panel , making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required. complete rate group 1 26 digital type 27 sf of ct operated direct reading type ampere meter on existing panel , making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required. complete rate group 1 28 digital type, below 500 a 29 sf of current transformer , with all necessary support in existing panel including connection etc. as required. complete rate group 1 30 from 200 / 5 to 400 / 5 ratio , 10 va , class 0.5 accuracy 31 sf of selector switch of 10 a for voltmeter ( 4 position ) including making connection etc. as required. complete rate group 1 32 sf of ct linked selector switch of 10 a for ampere meter ( 4 position ) including making connection etc. as required. complete rate group 1 33 sf of 110 / 220 v, led ( 22.5 mm dia ) indicating lamp with integral circuit, terminal block, including connection etc. as required. complete rate group 1 34 red / yellow / green colour 35 blue colour 36 sf of tap off boxes suitable for following size of approved design. complete rate group 1 37 from 120 sq. mm. to 185 sq. mm. ( 3.5 / 4 core ) 38 p & f of multy function meter with lcd / led display capable of measuring electrical parameters like v, i, f, pf, kw, kva, kvar, kwh, kvah, kvarh display with 1a / 5a ct input for lv / hv network, rs 485 communication port etc. complete in all respect. complete rate group 1 39 sitc of self healing mpp / mp type shunt capacitor ( banks ) conforming to is:13340 41 / iec :831 1&2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( psd ) and shall have dissipation factor less than 0.0025 at 50 hz and total wattage loss less than 0.5 watt per kvar . including making connections with suitable capacity conductors / cables testing etc. as required. complete rate group 1 40 heavy duty three phase 440 v , 50 hz capacitor ( bank ) 41 sitc of microprocessor based three phase sensing power factor correction relay having following sensing capacity secondary current , self analysing auto c / k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag / lead capacitor switching status, alarm output for under current, over current, insufficient compensation, indication of switching on units, auto / manual status, and shall have over load protection, no volt release , having multi parameter like kw, kva, kvar, metering facility as required. complete rate group 1 42 12 to 14 stage, sensitivity up to 50 milli amp 43 p & f cam operated rotary switches on existing panel with 2 way and off position complete rate group 1 44 three pole 32 a 45 p & f of 440 volt 3 pole capacitor ( ac 6 b ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors / reactors to limit the inrush current , conforming to is:13947 4 1 / iec:947 4 1, din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank.complete rate group 1 46 upto 6 kvar 47 7 to 10 kvar 48 11 to 20 kvar 49 p&f of removable voltage surge protection device ( surge arrester ) for protection against transient over voltage ( 8 / 20 micro seconds ) and to run current waves to ground, making connection, testing etc. as required. ( imax=40 ka, up= 1.2kv, uc=275 volts ) complete rate group 1 50 triple pole & neutral 51 sitc of quick make and quick break 4 pole current limiting mccb having following current rating, short circuit breaking capacity at 440 / 415 v, 50 hz; o / l & s / c settings and conforming to is 60947 2 / iec 60947 2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for uvr , shunt trip , earth fault trip, push ( test ) to trip , including making connections with lugs & spreaders, etc. as required. 52 250 amp , 35 ka, adjustable o / l & fixed s / c setting, ics = 100 % icu 53 supplying and making one end termination with heavy duty single compression brass gland sibg type, heavy duty copper lugs duly crimped with crimping tool, pvc tape etc for following size of armoured pvc insulated & pvc sheathed / xlpe aluminium conductor cable of 1100 volt grade as required of size. 54 3.5 x 120.0 sq.mm 55 3.5 x 185.0 sq.mm 56 p & laying xlpe insulated is:7098 / ii / 85 of group1 and approved make h.t.cable for working voltage 11 k.v.earthed direct in ground including excavation of 30cmx100cm size trench, 25cm layer of river sand, iind class bricks covering, refilling earth, compaction of earth, making necessary connection testing etc.as required of size. 57 3 core 185.0 sq.mm 58 plate earthing as per is:3043 with g.i. earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 25 mm dia. g.i. b class watering pipe including all accessories like nut, bolts, reducer , nipple, wire meshed funnel, and c.c. finished chamber covered with hinged type with locking arrangement c.i. cover, c.i. frame of size300mm x 300mm complete with alternate layers of salt and coke / charcoal, testing of earth resistance as required. 59 s & laying following size earth wire / strip in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection etc. as required. 60 8 swg g.i. ( hot dipped ) wire 61 p&f of heavy duty capacitor start, double ball bearing 900 / 1400 rpm single phase isi marked exhaust fan, is:2312 marked in existing opening including making connections testing etc. as required. 62 300 mm sweep ( 900 / 1400 rpm ) 63 supply & fabrication steel structure with ms channel / angle / joist / ismb / sheet etc. including welding, rivetting, cutting, nut & bolt , painting etc. as required. 64 p & f of ip20 led batten type light fixture made from crca sheet steel housing suitable for moutning led tube system ( integral driver ) , power consumption of 18w / 36w 1500 3000 lumens, system lumen efficiency 80 lm / watt output, life time of 50, 000 burning hours with 70% initial lumen maintained. cct 3000°k, 4000°k & 6000°k.. 65 4 led tube shape fixture 18w 66 providing & making heat shrinkable type nindoor / outdoor / straight through terminations / joint kit of group1 and approved make suitable for xlpe insulated 11 kv / 33 kv cable, with required components, prepration of cable nends, testing etc. as required of following sizes . 67 11 kv end termination kit indoor type 68 3 core 120 / 150 / 185 / 225 sq.mm 69 sitc of 11 kv, 400 / 630 a, 20ka / 3 sec, out door, extensible type ring main unit ( rmu ) in suitable rcc foundation with 2 no. load break switch & 1 no. vcb / sf6 circuit breaker with over load, earth fault, short circuit relay, copper bus bar, earthing switch, mechanical on / off / earth indication, voltage presence indicator, ring core protection ct 2.5 va, 10p10 as per transformer rating, shunt trip coil, anti reflex operating handle, right angle boots etc. as required. 70 p / laying p.v.c. / xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick nunder layer of sand, iind class bricks covering, refilling earth, compaction of earth, making necessary connection testing etc. as required of size. 71 185.0 sq.mm x 3.5 core 72 supply and filling of filtered ehv grade transformer oil, up to the normal oil level. the oil shall conform to is: 335 1993 and should be isi marked and having the specified aging characteristics. the transformer oil sample taken from the transformer shall be subject to testing. 73 supply and filling of dehydrating agent silica gel breather with silica gel crystal. breather shall be of dia cast alluminium body. the moisture absorption shall be indicated by a change in the colour of the silica gel crystals which should be easily visible from a distance. silica gel conforming to is 3401 for transformers. 74 for 250 kva trf. 75 for 160 kva trf. 76 providing and fixing of complete gaskit & bolt for 160 kva trf. gasket shall be of min. 6 mm thick neoprene rubberized oil resistant cork sheets conforming to type b or c as per is 4253 part ii. g.i. nut bolts shall be of size m 10 x 40 mm / 3 / 8x1.5” long with two flat washers, suitably spaced ( as specified ) to press the cover. 77 for ht side of 160 kva trf. 78 for lt side of 160 kva trf. 79 for top cover of 160 kva trf. 80 for ht side of 250 kva trf. 81 for lt side of 250 kva trf. 82 for top cover of 250 kva trf. 83 providing and fixing of brass rod 12 mm diameter for ht terminals of 160 kva traf. metal part shall be of m 12 brass. 84 hv side bushing of 160 kva trf. bushing shall be of 17.5 kv / 250 a class, porcelain / polycrate with non adjustable, single gap type arcing horns 85 providing and fixing of drain cum sampling valve of preferbly steel at the bottom side of the tank. the necessary arrangement for locking on this valve by providing ms sheet box duly welded on tank body. for 250 kva trf. 86 prtoviding and fixing of temprature meter for regular monitoring of temprature of transformer oil of trf. temprature range shall be from 0 to 90 degree. 87 for 160 kva trf. 88 for 250 kva trf....

Rajasthan Police Housing & Construction Corporation Limited - Rajasthan

21558257 supply of different electrical material and electrical accessories for electrical maintenance work of residential quarters at rpa , shastrinagar , jaipur pvc casing capping along with accessories like coupler, inner, outer, elbow, square box, tee etc , pvc conduit along with accessories in surface / recessed using saddles, clamps, fastener , pvc insulated & unsheathed flexible copper conductor isi marked , p.v.c. sheet , phenolic laminated sheet , 6 amp. flush type switch, 240 / 415 v isolator, 18 swg sheet steel boxes , paper phenolic resin bonded , isi marked ( is :3854 ) bell push surface...

Public Works Department - Rajasthan

19737513 supply and fixing of regular electric material in hospital kekri copper conductor, paper phenolic resin bonded laminates, , 240 / 415 v ac mcb with positive insolation , single pole mcb, double pole mcb, 6 amp flush trype switch , 6 amp flush type socket, flush type socket including cutting hole, socket, mechanical / digital time switch , break 4 pole current limiting mccb , with thermal magnetic release, pvc cable junction boxes, etc.....

Government Medical College - Rajasthan

16322690 two year rate contract of supply of electric and pvc wire and cables accessories 4.07 supply of composite ballast with igniter /capacitor of superior quality. for sodium/mh lamp 250w/400w 5 geyser/fridge/cooler / fan & other misc items 5.01 supply of isi marked ( is:14927 p ii ) pvc casing capping 5.011 20mmx12mm 5.012 25mmx12mm 5.013 32mmx12mm 5.02 supply of paper phenolic resin bonded laminates confirming to is : 2036 1995 for boxes/ frames ( sunmica sheet ) 3.0 mm thick as required size including with hole for accessories 5.03 supply of teflon tape ¾” (champion/equivalent make) 5.04 supply of 12volt 50watt bulb with holder of lieca or equivalent 5.05 supply of insulation pvc tape adhesive (3mtr length) 1” 5.06 supply of insulation pvc tape adhesive (10 mtr length) 3/4” 5.07 supply of ups complete for desktop personal computer of luminous/ips (600 va rating 20 minutes battery backup) 5.08 supply of stem type snap action bipolar adjustable thermostat with built in auto thermal cut off of storage water heater. 5.09 supply of rubber gutkha 12 soot suitable for exhaust fan 5.10 supply of rubber gutkha 18 soot suitable for exhaust fan 5.11 supply of rubber gutkha big size suitable for ceiling fan 5.12 clamp set suitable foe ceiling fan complete with rubber gutkha and nut bolt with washer as required 5.13 nut bolt 2 soot 2.5 inch long half threaded make w zink 5.14 supply of bearing 6201 suitable for fans make skf / nbc 5.15 supply of bearing 6202 suitable for fans make skf / nbc 5.16 supply of bearing 6203 suitable for fans make skf / nbc 5.17 wire sealeave 1,2,3 and 4 number 5.18 supply of voltage stabilizer having output voltage variation from 200v to 250v (±5%) with input voltage variation from 170v to 260v, time delay facility from 2 to 4 minute and high cutoff at 270v 5.19 supply of fr pvc insulated & unsheathed flexible copper conductor isi marked (is:694) of 1.1 kv grade 6 supply of telephone cables & instruments ...

Rajasthan Council Of Secondary Education - Rajasthan

14602816 tender for civil work at gsss, charla 1.02 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. all kinds of soils 1.03 pcc in foundation : providing and laying in position cement concrete including curing compaction etc. 1.04 random rubble stone masonry for with hard stone in foundation and plinth in cement sand mortar above 30 cm thick wall in cement mortat 1:6 ( 1 cement: 6 sand ) , providing and fixing of 18 swg sheet steel boxes 2.26 paper phenolic resin bonded laminates c 2.27 socket size flush type 120 / 280 watt rotary 5 step fan regulator including making connection testing etc....

Public Health Engineering Department - Rajasthan

12646360 supply and fixing of electric spare parts under city div ii jodhpur ( phe1718wsrc01845 ) 1.1 e040604 6.0 sq.mm 3 core flat / round 1.2 e040605 10.0 sq.mm 3 core flat / round 2 e050500 p & f paper phenolic resin bonded laminates confirming to is : 2036 1995 for boxes / frames including making holes for switches etc, with brass screws, washers / zinc plated nut and bolts as required. 2.1 e050504 9.0 mm thick 3 e051800 p & f 3 way male female connector 4 e060100 p&f 240 / 415 v ac mcb with positive isolation breaking capacity not less than 10 ka ( b / c / d tripping characteristic ) isi marked is 8828 ( 1996 ) ] / conforming iec 60898 in existing board / sheets including making connections, testing etc. as required. 4.1 e060112 6 a to 32 a rating 4.2 e060142 40 a 63 a rating 4.3 e060152 40 a 63 a rating 5 e060200 p&f 240 / 415 v isolator conforming to is:13947 iii / iec 60947 3 on existing board / sheet including making connections, testing etc. as required. 5.1 e060230 four pole isolator: 100a rating 6 e061000 p&f recessed / surface mounting heavy duty vertical type 16 swg sheet steel distribution board with provision incomer suitable for mcb / rccb and sp / tp mcb outgoing , phophatised , powder painted complete with insulated suitable rating copper bus bar , neutral link, earth link and din bar, masking sheet, conforming is13032 & is8623 including making internal db terminations with copper lugs , testing etc. as required. double door 8.1 e080301 analog type ( 96 mm x 96 mm ) 9 e080400 sf of ct operated direct reading type ampere meter on existing panel , making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required. 9.1 e080410 analog type ( 96 mm x 96 mm ) below 500 a 10 e080500 sf of current transformer , with all necessary support in existing panel including connection etc. as required . 10.1 e080502 from 200 / 5 to 400 / 5 ratio , 10 va , class 1 accuracy 11 e080600 sf of selector switch of 10 a for voltmeter ( 4 position including making connection etc. as required . 12 e080700 sf of ct linked selector switch of 10 a for ampere meter ( 4 position ) including making connection etc. as required . 13 e080800 sf of 110 / 220 v, led ( 22.5 mm dia ) indicating lamp with integral circuit, terminal block, including connection etc. as required. 13.1 e080801 red / yellow / green colour 14 e081100 s & f of electrical insulating rubber matts confirming to is: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. 14.1 e081103 33 kv, 3 mm thick with proof voltage 36 kv / 3 min. and break down voltage 65 kv...